Registers refreshed 2026-11-20.See refresh dates
China

SGS-CSTC Standards Technical Services (Shanghai) Co.,

No. 588 West Jindu Road, Xinqiao, Songjiang, Shanghai, 201612, People's Republic of China, Xinqiao, Songjiang, Shanghai, China

Visit website
A2LA 6332.01A2LA 6332.06ISO/IEC 17025Register refreshed 2026-11-20
One of 2 sites of this organization in our directory. View the organizationPart of the SGS group: 171 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
253
A2LA certificates
2
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 253 standard numbers and the 117 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60601 series82
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60601-1-3
IEC 60601-1-5
IEC 60601-1-6
IEC 60601-1-8
IEC 60601-1-10
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environmentExclusion

Limits written next to it

IEC 60601-1-11 (Excluding Cl 4.2, 8.3, 10.1, 12)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

IEC 60601-1-12Exclusion

Limits written next to it

IEC 60601-1-12 (Excluding Cl 6.2, 8.1, 10.1, 12)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

ANSI/AAMI/IEC 60601-1-12 (Excluding Cl 6.2, 8.1, 10.1)

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01.

EN 60601-1-12 (Excluding Cl 6.2, 8.1, 10.1)

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

IEC 60601-1-36
IEC 60601-1-86
IEC 60601-1-116Exclusion

Limits written next to it

EN 60601-1-116 (Excluding Cl 4.2, 8.3, 10.1)

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

IEC 60601-2-2Exclusion

Limits written next to it

IEC 60601-2-2 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 16 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01.

Show all 82
IEC 60601-2-3Exclusion

Limits written next to it

IEC 60601-2-3 (Excluding Cl 201.17)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-3 (Excluding Cl 201.17)

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

IEC 60601-2-4Exclusion

Limits written next to it

IEC 60601-2-4 (Excluding Cl 201.11.6.3, 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

ANSI/AAMI/IEC 60601-2-4 (Excluding Cl 201.11.6.3, 201.17

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

EN 60601-2-4 (Excluding Cl 201.11.6.3, 201.17, 202)

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

IEC 60601-2-5Exclusion

Limits written next to it

IEC 60601-2-5 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-5 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

IEC 60601-2-6Exclusion

Limits written next to it

IEC 60601-2-6 (Excluding Cl 201.10.3.101, 201.10.3.102

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-6 (Excluding Cl 201.10.3.101, 201.10.3.102

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

IEC 60601-2-8
IEC 60601-2-10Exclusion

Limits written next to it

IEC 60601-2-10 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-10 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

IEC 60601-2-11
IEC 60601-2-16Exclusion

Limits written next to it

IEC 60601-2-16 (Excluding Cl 201.17)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01.

IEC 60601-2-16 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01.

IEC 60601-2-17
IEC 60601-2-18Exclusion

Limits written next to it

IEC 60601-2-18 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-18 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-19Exclusion

Limits written next to it

IEC 60601-2-19 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-20Exclusion

Limits written next to it

IEC 60601-2-20 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-21Exclusion

Limits written next to it

IEC 60601-2-21 (Excluding Cl 201.10.6, 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

ANSI/AAMI/IEC 60601-2-21 (Excluding Cl 201.10.6, 201.17

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

IEC 60601-2-22Exclusion

Limits written next to it

IEC 60601-2-22 (Excluding Cl 201.10, 201.10.4, 201.12.1

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-23Exclusion

Limits written next to it

IEC 60601-2-23 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-23 (Excluding Cl 201.10.6, 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-24Exclusion

Limits written next to it

IEC 60601-2-24 (Excluding Cl 201.11.6.3, 201.11.6.5, 201.17

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-24 (Excluding Cl 201.11.6.3, 201.11.6.5, 201.17

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-25Exclusion

Limits written next to it

IEC 60601-2-25 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01.

EN 60601-2-25 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-26Exclusion

Limits written next to it

IEC 60601-2-26 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-26 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-27Exclusion

Limits written next to it

IEC 60601-2-27 (Excluding Cl 201.11.6.5, 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

ANSI/AAMI/IEC 60601-2-27 (Excluding Cl 201.11.6.5, 201.17

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

EN 60601-2-27 (Excluding Cl 201.11.6.5, 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-28Medical electrical equipment - Part 2-28: Particular requirements for the basic safety and essential performance of X-ray tube assemblies for medical diagnosis
IEC 60601-2-29
IEC 60601-2-30Exclusion

Limits written next to it

IEC 60601-2-30 (Excluding Cl 36)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-30 (Excluding Cl 36)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-31Exclusion

Limits written next to it

IEC 60601-2-31 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-33Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis
IEC 60601-2-34Exclusion

Limits written next to it

IEC 60601-2-34 (Excluding Cl 201.11.6.5, 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-34 (Excluding Cl 201.11.6.5, 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-35Exclusion

Limits written next to it

IEC 60601-2-35 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-36Exclusion

Limits written next to it

IEC 60601-2-36 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-36 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-37Exclusion

Limits written next to it

IEC 60601-2-37 (Excluding Cl 201.11.6.5, 201.17, 202.6)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-38Exclusion

Limits written next to it

IEC 60601-2-38 (Excluding Cl 36)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01.

EN 60601-2-38 (Excluding Cl 36)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-39Exclusion

Limits written next to it

IEC 60601-2-39 (Excluding Cl 201.10, 201.17)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-40Exclusion

Limits written next to it

IEC 60601-2-40 (Excluding Cl 201.17)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-040
IEC 60601-2-41Exclusion

Limits written next to it

IEC 60601-2-41 (Excluding Cl 201.17)

Exclusion. Written next to it on line 14 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-43Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
IEC 60601-2-44Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography
IEC 60601-2-45Medical electrical equipment - Part 2-45: Particular requirements for the basic safety and essential performance of mammographic X-ray equipment and mammographic stereotactic devices
IEC 60601-2-46Medical electrical equipment - Part 2-46: Particular requirements for the basic safety and essential performance of operating tablesExclusion

Limits written next to it

IEC 60601-2-46 (Excluding Cl 201.11.6.5, 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01.

IEC 60601-2-47Exclusion

Limits written next to it

IEC 60601-2-47 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01.

EN 60601-2-47 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-49Exclusion

Limits written next to it

IEC 60601-2-49 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01.

EN 60601-2-49 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-50Exclusion

Limits written next to it

IEC 60601-2-50 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-51
IEC 60601-2-52Exclusion

Limits written next to it

IEC 60601-2-52 (Excluding Cl 201.9, 201.17)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01.

EN 60601-2-52 (Excluding Cl 201.9, 201.17)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-54Medical electrical equipment - Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy
IEC 60601-2-57Exclusion

Limits written next to it

IEC 60601-2-57 (Excluding Cl 201.10.103, 201.12.4.2

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01.

EN 60601-2-57 (Excluding Cl 201.10.103, 201.12.4.2

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-62Exclusion

Limits written next to it

IEC 60601-2-62 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01.

EN 60601-2-62 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-63
IEC 60601-2-64
IEC 60601-2-65
IEC 60601-2-66Exclusion

Limits written next to it

IEC 60601-2-66 (Excluding Cl 201.17)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-68
IEC 60601-2-75Exclusion

Limits written next to it

IEC 60601-2-75 (Excluding Cl 201.12.1.101, 201.12.1.102

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-76Exclusion

Limits written next to it

IEC 60601-2-76 (Excluding Cl 201.17)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01.

IEC 60601-2-83Exclusion

Limits written next to it

IEC 60601-2-83 (Excluding Cl 201.6, 201.10, 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 60601-2-86Exclusion

Limits written next to it

EN 60601-2-86 (Excluding Cl 201.17)

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

IEC 60601-2-116Exclusion

Limits written next to it

EN 60601-2-116 (Excluding Cl 201.11.6.3, 201.17)

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

IEC 60601-2-176Exclusion

Limits written next to it

EN 60601-2-176 (Excluding Cl 201.17)

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

IEC 60601-2-286Exclusion

Limits written next to it

EN IEC 60601-2-286 (Excluding Cl 201.17)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-296Exclusion

Limits written next to it

EN 60601-2-296 (Excluding Cl 201.17)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-336Exclusion

Limits written next to it

EN IEC 60601-2-336 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-436Exclusion

Limits written next to it

EN IEC 60601-2-436 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-446Exclusion

Limits written next to it

EN 60601-2-446 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-456Exclusion

Limits written next to it

EN 60601-2-456 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-466Exclusion

Limits written next to it

IEC 60601-2-466 (Excluding Cl 201.11.6.5, 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01.

EN IEC 60601-2-466 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-546Exclusion

Limits written next to it

EN IEC 60601-2-546 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-636Exclusion

Limits written next to it

EN 60601-2-636 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-646Exclusion

Limits written next to it

EN IEC 60601-2-646 (Excluding Cl 201.17)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-656Exclusion

Limits written next to it

EN 60601-2-656 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-2-686Exclusion

Limits written next to it

EN IEC 60601-2-686 (Excluding Cl 201.17)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

IEC 60601-15
IEC 60601-16Exclusion

Limits written next to it

EN 60601-16 (Excluding Cl 8.8.4.1, 9.7.5, 10.4, 11.6.5, 17)

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

ISO33
ISO 3964Dentistry - Coupling dimensions for handpiece connectors
ISO 5356-1Anaesthetic and respiratory equipment - Conical connectors - Part 1: Cones and sockets
ISO 5356-2Anaesthetic and respiratory equipment - Conical connectors - Part 2: Screw-threaded weight-bearing connectors
ISO 5367Anaesthetic and respiratory equipment - Breathing sets and connectors
ISO 5467-1Dentistry - Mobile dental units and dental patient chairs - Part 1: General requirements
ISO 5467-2Dentistry - Mobile dental units and dental patient chairs - Part 2: Air, water, suction and wastewater systems
ISO 6875Dentistry - Patient chairExclusion

Limits written next to it

ISO 6875 (Excluding Cl 7.2.6)

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01.

ISO 7494-1Dentistry - Stationary dental units and dental patient chairs - Part 1: General requirements
ISO 7494-2Dentistry - Stationary dental units and dental patient chairs - Part 2: Air, water, suction and wastewater systems
ISO 8185Respiratory tract humidifiers for medical use - Particular requirements for respiratory humidification systems
ISO 8359Oxygen concentrators for medical use - Safety requirements
ISO 8500-6
Show all 33
ISO 8835-2Inhalational anaesthesia systems - Part 2: Anaesthetic breathing systems
ISO 9168Dentistry - Hose connectors for air driven dental handpieces
ISO 9680Dentistry - Operating lightsExclusion

Limits written next to it

ISO 9680 (Excluding 7.4.3)

Exclusion. Written next to it on line 7 of A2LA certificate 6332.01; Line 9 of A2LA certificate 6332.01.

ISO 9919Medical electrical equipment - Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use
ISO 10535Assistive products - Hoists for the transfer of persons - Requirements and test methods
ISO 10651-3Lung ventilators for medical use - Part 3: Particular requirements for emergency and transport ventilatorsExclusion

Limits written next to it

ISO 10651-3 (Excluding Cl 4.1, 5.8, 7.3, 201.17, 202)

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01.

ISO 10651-4Lung ventilators - Part 4: Particular requirements for user-powered resuscitators
ISO 11981Ophthalmic optics - Contact lenses and contact lens care products - Determination of physical compatibility of contact lens care products with contact lenses
ISO 14457Dentistry - Handpieces and motorsExclusion

Limits written next to it

ISO 14457 (Excluding Cl 7.22.1)

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01.

ISO 15004-1Ophthalmic instruments - Fundamental requirements and test methods - Part 1: General requirements applicable to all ophthalmic instrumentsExclusion

Limits written next to it

EN ISO 15004-1 (Excluding Cl 7.2)

Exclusion. Written next to it on line 19 of A2LA certificate 6332.01.

ISO 15197In vitro diagnostic test systems - Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus
ISO 16840-10Wheelchair seating - Part 10: Resistance to ignition of postural support devices - Requirements and test method
ISO 18369-3Ophthalmic optics - Contact lenses - Part 3: Measurement methods
ISO 18369-4Ophthalmic optics - Contact lenses - Part 4: Physicochemical properties of contact lens materialsExclusion

Limits written next to it

ISO 18369-4 (excluding sections 4.2 and 4.3)

Exclusion. Written next to it on line 1 of A2LA certificate 6332.06.

ISO 21647Medical electrical equipment - Particular requirements for the basic safety and essential performance of respiratory gas monitors
ISO 23371Anaesthetic and respiratory equipment - Cuff pressure indication, control and regulation devices
ISO 23402-1Dentistry - Portable dental equipment for use in non‐permanent healthcare environments - Part 1: General requirementsExclusion

Limits written next to it

ISO 23402-1 (Excluding Cl 5.2.9, 5.5.4)

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01.

ISO 23402-3Dentistry - Portable dental equipment for use in non‐permanent healthcare environment - Part 3: Portable suction equipmentExclusion

Limits written next to it

ISO 23402-3 (Excluding Cl 7.5)

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01.

ISO 27427Anaesthetic and respiratory equipment - Nebulizing systems and components
ISO 81060-1Non-invasive sphygmomanometers - Part 1: Requirements and test methods for non-automated measurement type
ISO 81060-2Non-invasive sphygmomanometers - Part 2: Clinical investigation of intermittent automated measurement type
ISO 7176 series21
ISO 7176-1Wheelchairs - Part 1: Determination of static stability
ISO 7176-2Wheelchairs - Part 2: Determination of dynamic stability of electrically powered wheelchairs
ISO 7176-3Wheelchairs - Part 3: Determination of effectiveness of brakes
ISO 7176-4Wheelchairs - Part 4: Energy consumption of electric wheelchairs and scooters for determination of theoretical distance range
ISO 7176-5Wheelchairs - Part 5: Determination of dimensions, mass and manoeuvring space
ISO 7176-6Wheelchairs - Part 6: Determination of maximum speed of electrically powered wheelchairs
ISO 7176-7Wheelchairs - Part 7: Measurement of seating and wheel dimensions
ISO 7176-8Wheelchairs - Part 8: Requirements and test methods for static, impact and fatigue strengths
ISO 7176-9Wheelchairs - Part 9: Climatic tests for electric wheelchairs
ISO 7176-10Wheelchairs - Part 10: Determination of obstacle-climbing ability of electrically powered wheelchairs
ISO 7176-13Wheelchairs - Part 13: Determination of coefficient of friction of test surfaces
ISO 7176-14Wheelchairs - Part 14: Power and control systems for electrically powered wheelchairs and scooters - Requirements and test methods
Show all 21
ISO 7176-15Wheelchairs - Part 15: Requirements for information disclosure, documentation and labelling
ISO 7176-16Wheelchairs - Part 16: Resistance to ignition of postural support devices
ISO 7176-19Wheelchairs - Part 19: Wheelchairs for use as seats in motor vehicles
ISO 7176-22Wheelchairs - Part 22: Set-up procedures
ISO 7176-23Wheelchairs - Part 23: Requirements and test methods for attendant-operated stair-climbing devices
ISO 7176-24Wheelchairs - Part 24: Requirements and test methods for user-operated stair-climbing devices
ISO 7176-25Wheelchairs - Part 25: Lead-acid batteries and chargers for powered wheelchairs - Requirements and test methods
ISO 7176-28Wheelchairs - Part 28: Requirements and test methods for stair-climbing devices
ISO 7176-31Wheelchairs - Part 31: Lithium-ion battery systems and chargers for powered wheelchairs - Requirements and test methods
ISO 80601 series18
ISO 80601-2-12Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilatorsExclusion

Limits written next to it

ISO 80601-2-12 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

ISO 80601-2-13Medical electrical equipment - Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation
ISO 80601-2-55Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitorsExclusion

Limits written next to it

ISO 80601-2-55 (Excluding Cl 201.11.6.5, 201.15, 201.17

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ISO 80601-2-56Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurementExclusion

Limits written next to it

ISO 80601-2-56 (Excluding Cl 201.11.6.5, 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ISO 80601-2-61Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipmentExclusion

Limits written next to it

ISO 80601-2-61 (Excluding Cl 201.11.6.5.101, 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01.

EN ISO 80601-2-61 (Excluding Cl 201.11.6.5.101, 201.17

Exclusion. Written next to it on line 19 of A2LA certificate 6332.01.

ISO 80601-2-67Medical electrical equipment - Part 2-67: Particular requirements for basic safety and essential performance of oxygen-conserving equipmentExclusion

Limits written next to it

ISO 80601-2-67 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ISO 80601-2-69Medical electrical equipment - Part 2-69: Particular requirements for the basic safety and essential performance of oxygen concentrator equipmentExclusion

Limits written next to it

ISO 80601-2-69 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ISO 80601-2-70Medical electrical equipment - Part 2-70: Particular requirements for basic safety and essential performance of sleep apnoea breathing therapy equipmentExclusion

Limits written next to it

ISO 80601-2-70 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ISO 80601-2-72Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patientsExclusion

Limits written next to it

ISO 80601-2-72 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ISO 80601-2-74Medical electrical equipment - Part 2-74: Particular requirements for basic safety and essential performance of respiratory humidifying equipmentExclusion

Limits written next to it

ISO 80601-2-74 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ISO 80601-2-79Medical electrical equipment - Part 2-79: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairmentExclusion

Limits written next to it

ISO 80601-2-79 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ISO 80601-2-80Medical electrical equipment - Part 2-80: Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory insufficiencyExclusion

Limits written next to it

ISO 80601-2-80 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

Show all 18
ISO 80601-2-84Medical electrical equipment - Part 2-84: Particular requirements for the basic safety and essential performance of ventilators for the emergency medical services environmentExclusion

Limits written next to it

ISO 80601-2-84 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ISO 80601-2-85Medical electrical equipment - Part 2-85: Particular requirements for the basic safety and essential performance of cerebral tissue oximeter equipmentExclusion

Limits written next to it

ISO 80601-2-85 (Excluding Cl 201.11.6.5.101, Cl 201.11.6.5

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01.

EN ISO 80601-2-85 (Excluding Cl 201.11.6.5.101

Exclusion. Written next to it on line 19 of A2LA certificate 6332.01.

ISO 80601-2-87Medical electrical equipment - Part 2-87: Particular requirements for basic safety and essential performance of high-frequency ventilatorsExclusion

Limits written next to it

ISO 80601-2-87 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ISO 80601-2-90Medical electrical equipment - Part 2-90: Particular requirements for basic safety and essential performance of respiratory high-flow therapy equipmentExclusion

Limits written next to it

ISO 80601-2-90 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ISO 80601-2-136Exclusion

Limits written next to it

EN ISO 80601-2-136 (Excluding Cl 201.17)

Exclusion. Written next to it on line 18 of A2LA certificate 6332.01.

ISO 80601-2-556Exclusion

Limits written next to it

ISO 80601-2-556 (Excluding Cl 201.11.6.5, 201.15, 201.17

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

IEC16
IEC 60825-1Some clausesExclusion

Limits written next to it

EN 60825-1 (Cl.4, 5)

Some clauses. Written next to it on line 11 of A2LA certificate 6332.01.

IEC 60825-1 (Cl.4, 5)

Some clauses. Written next to it on line 11 of A2LA certificate 6332.01.

EN 60825-1 (Excluding Cl.4, 5)

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01.

IEC 60825-1 (Excluding Cl.4, 5)

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01.

IEC 62040-1
IEC 62052-11
IEC 62059-31-1
IEC 62059-32-1
IEC 62083
IEC 62301
IEC 62304
IEC 62366-1
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national

National versions in the same scope

AS/NZS 62368.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 62368-1. Probably the same standard; not checked against the EN document.

IEC 62471Photobiological safety of lamps and lamp systemsExclusion

Limits written next to it

EN 62471 (Excluding Cl

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01.

IEC 62471 (Excluding Cl

Exclusion. Written next to it on line 16 of A2LA certificate 6332.01.

IEC 62586-1
IEC 62586-2
IEC 62623
IEC 80369-5
IEC 81001-5-1
IEC 61010 series15
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-010
IEC 61010-2-011
IEC 61010-2-012
IEC 61010-2-020
IEC 61010-2-030
IEC 61010-2-040Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
IEC 61010-2-051
IEC 61010-2-061
IEC 61010-2-081
IEC 61010-2-091
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
IEC 61010-2-130
IEC 61010-2-201
IEC 61010-16
EN9
EN 1789
EN 12182
EN 12183
EN 12184
EN 12469
EN 13544-1
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50131-5-3
EN 50470-4
IEC 80601 series9
IEC 80601-2-26Exclusion

Limits written next to it

IEC 80601-2-26 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 18 of A2LA certificate 6332.01.

IEC 80601-2-30Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometersExclusion

Limits written next to it

IEC 80601-2-30 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

EN 80601-2-30 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 19 of A2LA certificate 6332.01.

IEC 80601-2-35Exclusion

Limits written next to it

IEC 80601-2-35 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01.

EN 80601-2-35 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 19 of A2LA certificate 6332.01.

IEC 80601-2-49Exclusion

Limits written next to it

IEC 80601-2-49 (Excluding Cl 201.11.6.5, 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

IEC 80601-2-58Exclusion

Limits written next to it

IEC 80601-2-58 (Excluding Cl 201.12.1.101.5, Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01.

ANSI/AAMI/IEC 80601-2-58 (Excluding Cl 201.12.1.101.5

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

ANSI/AAMI/IEC 80601-2-58 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 17 of A2LA certificate 6332.01.

EN IEC 80601-2-58 (Excluding Cl 201.12.1.101.5, 201.17

Exclusion. Written next to it on line 19 of A2LA certificate 6332.01.

IEC 80601-2-59Exclusion

Limits written next to it

IEC 80601-2-59 (Excluding Cl 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

IEC 80601-2-60Exclusion

Limits written next to it

IEC 80601-2-60 (Excluding Cl 201.17)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

EN 80601-2-60 (Excluding Cl 201.17)

Exclusion. Written next to it on line 19 of A2LA certificate 6332.01.

IEC 80601-2-78Exclusion

Limits written next to it

IEC 80601-2-78 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

IEC 80601-2-776Exclusion

Limits written next to it

IEC 80601-2-776 (Excluding Cl 201.17, 202)

Exclusion. Written next to it on line 15 of A2LA certificate 6332.01; Line 17 of A2LA certificate 6332.01; Line 19 of A2LA certificate 6332.01.

ASTM8
ASTM E1112
ASTM E1965
ASTM F640
ASTM F2052
ASTM F2119
ASTM F2182
ASTM F2213
ASTM F2503
ETSI7
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-13
ETSI EN 303 447
ETSI EN 303 883-1
ETSI EN 303 883-2
ISO 8600 series6
ISO 8600-1Endoscopes - Medical endoscopes and endotherapy devices - Part 1: General requirements
ISO 8600-3Endoscopes - Medical endoscopes and endotherapy devices - Part 3: Determination of field of view and direction of view of endoscopes with optics
ISO 8600-4Endoscopes - Medical endoscopes and endotherapy devices - Part 4: Determination of maximum width of insertion portion
ISO 8600-5Optics and photonics - Medical endoscopes and endotherapy devices - Part 5: Determination of optical resolution of rigid endoscopes with optics
ISO 8600-7Endoscopes - Medical endoscopes and endotherapy devices - Part 7: Basic requirements for medical endoscopes of water-resistant type
ISO 8600-8Endoscopes - Medical endoscopes and endotherapy devices - Part 8: Particular requirements for capsule endoscopes
CISPR5
CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

AS/NZS CISPR 13identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55013. Probably the same standard; not checked against the EN document.

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national

National versions in the same scope

AS CISPR 14.1national version with changes

AS/NZS CISPR 14.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55014-1, IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Certificate says IEC 55014-2. Probably the same standard; not checked against the EN document.

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national

National versions in the same scope

AS CISPR 15national version with changes

AS/NZS CISPR 15national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55015, IEC 55015. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national

National versions in the same scope

AS/NZS CISPR 32identical to it

VCCI-CISPR 32probably the same standard; matched by number only

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

ISO 14708 series5
ISO 14708-1Implants for surgery - Active implantable medical devices - Part 1: General requirements for safety, marking and for information to be provided by the manufacturer
ISO 14708-2Implants for surgery - Active implantable medical devices - Part 2: Cardiac pacemakers
ISO 14708-3Implants for surgery - Active implantable medical devices - Part 3: Implantable neurostimulators
ISO 14708-6Implants for surgery - Active implantable medical devices - Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators)
ISO 14708-7Implants for surgery - Active implantable medical devices - Part 7: Particular requirements for cochlear and auditory brainstem implant systems
IEC 61000 series4
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national

National versions in the same scope

AS/NZS 61000.3.2identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national

National versions in the same scope

AS/NZS 61000.3.3identical to it

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-4-30
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

ISO 10079 series4
ISO 10079-1Medical suction equipment - Part 1: Electrically powered suction equipment
ISO 10079-2Medical suction equipment - Part 2: Manually powered suction equipment
ISO 10079-3Medical suction equipment - Part 3: Suction equipment powered from a vacuum or positive pressure gas source
ISO 10079-4Medical suction equipment - Part 4: General requirements
ISO 80369 series4
ISO 80369-1Small-bore connectors for liquids and gases in healthcare applications - Part 1: General requirements
ISO 80369-2Small-bore connectors for liquids and gases in healthcare applications - Part 2: Connectors for respiratory applications
ISO 80369-7Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications
ISO 80369-20Small-bore connectors for liquids and gases in healthcare applications - Part 20: Common test methods
EN 12470 series3
EN 12470-3
EN 12470-4
EN 12470-5
ISO 11199 series3
ISO 11199-1Assistive products for walking manipulated by both arms - Requirements and test methods - Part 1: Walking frames
ISO 11199-2Assistive products for walking manipulated by both arms - Requirements and test methods - Part 2: Rollators
ISO 11199-3Walking aids manipulated by both arms - Requirements and test methods - Part 3: Walking tables
Other standards1
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz

Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.

Scope as published by A2LA

28 lines
A2LA

ISO/IEC 17025

Active

6332.01

The scope document we hold says it is valid until 2028-07-31.

View scope
A2LA

ISO/IEC 17025

Active

6332.06

The scope document we hold says it is valid until 2028-07-31.

View scope