Mettler Toledo (Industrial)
1900 Polaris Parkway, 43240, Columbus, OH, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 1902.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 500 mg |
| 2 | ASTM 2; NIST F | - | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1902.01) 07/21/2025 Page 3 of 4
Parameter/Equipment
Range CMC 2, 5 (±) Comments
Balances and Scales,
Avoirdupois
3
≤ 0.2 lb
(> 0.2 to ≤ 0.5) lb
(> 0.5 to ≤ 1) lb
(> 1 to ≤ 2) lb
(> 2 to ≤ 3) lb
(> 3 to ≤ 4) lb
(> 4 to ≤ 5) lb
(> 5 to ≤ 6) lb
(> 6 to ≤ 7) lb
(> 7 to ≤ 7.5) lb
(> 7.5 to ≤ 8) lb
(> 8 to ≤ 9) lb
(> 9 to ≤ 10) lb
(> 10 to ≤ 12) lb
(> 12 to ≤ 15) lb
(> 15 to ≤ 20) lb
(> 20 to ≤ 25) lb
(> 25 to ≤ 30) lb
(> 30 to ≤ 40) lb
(> 40 to ≤ 50) lb
(> 50 to ≤ 60) lb
(> 60 to ≤ 70) lb
(> 70 to ≤ 75) lb
(> 75 to ≤ 80) lb
(> 80 to ≤ 100) lb
(> 100 to ≤ 120) lb
(> 120 to ≤ 150) lb
(> 150 to ≤ 200) lb
(> 200 to ≤ 250) lb
(> 250 to ≤ 300) lb
(> 300 to ≤ 400) lb
(> 400 to ≤ 500) lb
(> 500 to ≤ 700) lb
(> 700 to ≤ 1000) lb
(> 1000 to ≤ 1500) lb
(> 1500 to ≤ 2000) lb
(> 2000 to ≤ 2500) lb
(> 2500 to ≤ 3000) lb
(> 3000 to ≤ 4000) lb
(> 4000 to ≤ 5000) lb
(> 5000 to ≤ 7000) lb
(> 7000 to ≤ 10 000) lb
(> 10 000 to ≤ 15 000) lb
(> 15 000 to ≤ 20 000) lb
(> 20 000 to ≤ 25 000) lb
(> 25 000 to ≤ 30 000) lb
(> 30 000 to ≤ 40 000) lb
(> 40 000 to ≤ 50 000) lb
(> 50 000 to ≤ 60 000) lb
0.000 17 lb
0.000 20 lb
0.000 24 lb
0.000 29 lb
0.000 55 lb
0.000 64 lb
0.000 73 lb
0.000 84 lb
0.000 94 lb
0.0011 lb
0.0013 lb
0.0014 lb
0.0015 lb
0.0017 lb
0.0024 lb
0.0029 lb
0.0035 lb
0.0040 lb
0.0051 lb
0.0063 lb
0.0084 lb
0.0094 lb
0.010 lb
0.013 lb
0.015 lb
0.017 lb
0.020 lb
0.048 lb
0.051 lb
0.055 lb
0.095 lb
0.10 lb
0.12 lb
0.15 lb
0.45 lb
0.48 lb
0.51 lb
0.55 lb
0.64 lb
0.73 lb
1.2 lb
1.5 lb
4.5 lb
4.8 lb
5.1 lb
5.5 lb
6.4 lb
7.3 lb
8.4 lb
NIST F weights | ||
| 4 | - | Balances and Scales, Avoirdupois; Tank Scales, Metric; Tank Scales, AvoirdupoisShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1902.01) 07/21/2025 Page 4 of 4
Parameter/Equipment
Range CMC 2, 5 (±) Comments
Balances and Scales,
Avoirdupois
3 (cont)
(> 60 000 to ≤ 70 000) lb
(> 70 000 to ≤ 100 000) lb
(> 100 000 to ≤ 120 000) lb
18 lb
20 lb
22 lb
NIST F weights
Tank Scales, Metric3
Tank Scales,
Avoirdupois
3
(≥ 1000 to ≤ 4000) kg
(> 4000 to ≤ 8000) kg
(> 8000 to ≤ 12 000) kg
(> 12 000 to ≤ 16 000) kg
(> 16 000 to ≤ 24 000) kg
(> 24 000 to ≤ 32 000) kg
(≥ 2200 to ≤ 8800) lb
(> 8800 to ≤ 17 600) lb
(> 17 600 to ≤ 26 400) lb
(> 26 400 to ≤ 35 000) lb
(> 35 000 to ≤ 53 000) lb
(> 53 000 to ≤ 70 000) lb
0.99 kg
1.7 kg
2.3 kg
2.8 kg
4.2 kg
5.0 kg
2.2 lb
3.7 lb
5.1 lb
6.7 lb
9.1 lb
11 lb
RapidCal™ Tank
Scale Calibration
RapidCal™ Tank
Scale Calibration
___________________________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This accreditation includes those field service repr esentatives located in the United States and Canada
reporting to Mettler Toledo (Industrial), Columbus, OH.
5 CMC components that can be reasonably attributed to the Unit Under Test have not been utilized in the
calculation of the CMC value for this measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy. | See scope document |
| 5 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Technical Maintenance, Inc. - HILLIARDHilliard, OH · ~15 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- American Testing Services,Miamisburg, OH · ~113 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - DaytonSpringboro, OH · ~115 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Western Environmental a Division of Controlled Environment Systems (CES)Springboro, OH · ~115 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instrument Calibration SolutionsClayton, OH · ~116 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.