FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Japan

QSES Inc. Testing Laboratory

3032 Nakabyo, Abiko-Shi, Chiba, 270-1121, Japan, Abiko-Shi, Chiba, Japan

A2LA|3914.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
4
Standards
11
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at QSES Inc. Testing Laboratory?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
3914.01Active

Accredited standards

11

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 61000 series

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 2 (A2LA 3914.01)

JIS C 1010-1; CISPR 11; EN 55011; KS C 9811; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; CISPR 16-2-3; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
As written on the certificate · Line 2 (A2LA 3914.01)

JIS C 1010-1; CISPR 11; EN 55011; KS C 9811; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; CISPR 16-2-3; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
As written on the certificate · Line 2 (A2LA 3914.01)

JIS C 1010-1; CISPR 11; EN 55011; KS C 9811; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; CISPR 16-2-3; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
As written on the certificate · Line 2 (A2LA 3914.01)

JIS C 1010-1; CISPR 11; EN 55011; KS C 9811; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; CISPR 16-2-3; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
As written on the certificate · Line 3 (A2LA 3914.01)

IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; IEC 61000-4-11; IEC 61000-4-34; EN 61000-4-11; KS C 9610-4-11; SEMI F47

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
As written on the certificate · Line 3 (A2LA 3914.01)

IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; IEC 61000-4-11; IEC 61000-4-34; EN 61000-4-11; KS C 9610-4-11; SEMI F47

IEC 61000-4-34Name not checked yet
As written on the certificate · Line 3 (A2LA 3914.01)

IEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; IEC 61000-4-11; IEC 61000-4-34; EN 61000-4-11; KS C 9610-4-11; SEMI F47

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
As written on the certificate · Line 2 (A2LA 3914.01)

JIS C 1010-1; CISPR 11; EN 55011; KS C 9811; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; CISPR 16-2-3; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
As written on the certificate · Line 2 (A2LA 3914.01)

JIS C 1010-1; CISPR 11; EN 55011; KS C 9811; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; CISPR 16-2-3; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6

Other standards

CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurementCertificate says EN 55011. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 2 (A2LA 3914.01)

JIS C 1010-1; CISPR 11; EN 55011; KS C 9811; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; CISPR 16-2-3; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6

IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
As written on the certificate · Line 1 (A2LA 3914.01)

IEC 61010-1*; EN 61010-1*; UL 61010-1*; CAN/CSA-C22.2 No. 61010-1*; JIS C 1010-1

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

3914.01

The scope document we hold says it was valid until 2026-04-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 3914.01

LineDisciplineMethodMatrixRange
1electricalIEC 61010-1*; EN 61010-1*; UL 61010-1*; CAN/CSA-C22.2 No. 61010-1*; JIS C 1010-1-to 10 kV
2electricalJIS C 1010-1; CISPR 11; EN 55011; KS C 9811; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; CISPR 16-2-3; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-4-2; EN 61000-4-2; KS C 9610-4-2; IEC 61000-4-4; EN 61000-4-4; KS C 9610-4-4; IEC 61000-4-5; EN 61000-4-5; KS C 9610-4-5; IEC 61000-4-6; EN 61000-4-6; KS C 9610-4-6-to 1 GHz
3electricalIEC 61000-4-8; EN 61000-4-8; KS C 9610-4-8; IEC 61000-4-11; IEC 61000-4-34; EN 61000-4-11; KS C 9610-4-11; SEMI F47--
4electrical
For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited QSES INC. TESTING LABORATORY Abiko-Shi, Chiba, Japan for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 12th day of June 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3914.01 Valid to April 30, 2026 Revised January 28, 2026

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3032 Nakabyo, Abiko-Shi, Chiba, 270-1121, Japan, Abiko-Shi, Chiba, JP

35.86400, 140.02807

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.