Mentor Technical Group Metrology
Caguas Real #100, Alhambra Granada Blvd., Caguas, 00725, Puerto Rico, Caguas, United States
Visit website- Scope lines
- 19
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 19 scope lines.
A2LA certificate 3595.01 · 19 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 2 of 18
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Calipers
3 (cont)
Up to 100 mm
(6 + 2L) µm
Gage blocks
Micrometers
3
Up to 1.0 in
(44 + 4.8L) µin
Gage blocks
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC
2, 5 (±)
Comments
DC Voltage – Generate
(0 to 329.999) mV
(0.33 to 3.299) V
(3.3 to 32.999) V
(33 to 329.999) V
(330 to 1020) V
22 μV/V + 1 μV
15 μV/V + 2 μV
11 μV/V + 20 μV
28 μV/V + 180 μV
0.018 mV/V + 2.7 mV
Multiproduct
calibrator
DC Voltage – Measure
Up to 100 mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
12 μV/V + 0.3 μV
9.0 μV/V + 0.3 μV
8.5 μV/V + 0.5 μV
11 μV/V + 30 μV
13 μV/V + 100 μV
Reference multimeter
DC Current – Generate
(0 to 329.9) µA
(0.3 to 3.29) mA
(3.3 to 32.9) mA
(33 to 329.9) mA
(330 mA to 2.9) A
(3 to 11) A
(11 to 20.5) A
0.015 % + 0.02 μA
0.010 % + 0.05 μA
0.010 % + 0.25 μA
0.010 % + 2.5 μA
0.025 % + 44 μA
0.05 % + 330 μA
0.1 % + 750 μA
Multiproduct
calibrator
DC Current –
Clamp-On Ammeter
(Non-Toroidal Type)
(15 to 150) A
(150 to 550) A
1.3 A
3.4 A
Multiproduct
calibrator with coil
DC Current –
Clamp-On Ammeter
(Toroidal & Other Types
of Clamp)
(15 to 150) A
(150 to 550) A
1.3 A
3.4 A
Multiproduct
calibrator with coil | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 3 of 18
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Current – Measure
100 nA to 10 µA
(10 to 100) µA
100 µA to 10 mA
(10 to 100) mA
100 mA to 1 A
25 µA/A + 0.12 nA
18 µA/A + 0.8 nA
22 µA/A + 55 nA
38 µA/A + 15 µA
0.014 % + 12 µA
Reference
multimeter
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate
(1 to 32.999) mV
(33 to 329.999) mV
330 mV to 3.2999 V
(3.3 to 32.999) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.08 % + 6 μV
0.03 % + 6 μV
0.03 % + 6 μV
0.09 % + 6 μV
0.3 % + 12 μV
0.74 % + 50 μV
0.03 % + 8 μV
0.01 % + 8 μV
0.01 % + 8 μV
0.03 % + 32 μV
0.07 % + 32 μV
0.17 % + 70 μV
0.03 % + 50 μV
0.01 % + 60 μV
0.02 % + 60 μV
0.02 % + 50 μV
0.02 % + 130 μV
0.2 % + 600 µV
0.02 % + 0.65 mV
0.01 % + 0.6 mV
0.02 % + 0.6 mV
0.03 % + 0.6 mV
0.07 % + 1.6 mV
Multiproduct
calibrator | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 4 of 18
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Generate
(cont)
(33 to 329.999) V
(330 to 1000) V
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.02 % + 2 mV
0.02 % + 6 mV
0.02 % + 6 mV
0.03 % + 6 mV
0.17 % + 50 mV
0.02 % + 10 mV
0.02 % + 10 mV
0.02 % + 10 mV
Multiproduct
calibrator
AC Current – Generate
(29 to 329.99) µA
(0.33 to 3.2999) mA
(3.3 to 32.9999) mA
(33 to 329.99) mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.29 % + 0.1 μA
0.27 % + 0.1 μA
0.25 % + 0.1 μA
0.36 % + 0.15 μA
0.76 % + 0.2 μA
1.5 % + 0.4 μA
0.18 % + 0.15 μA
0.12 % + 0.15 μA
0.10 % + 0.15 μA
0.17 % + 0.2 μA
0.41 % + 0.3 μA
0.81 % + 0.6 μA
0.16 % + 2.0 μA
0.09 % + 2.0 μA
0.06 % + 2.0 μA
0.08 % + 2.0 μA
0.18 % + 2.0 μA
0.34 % + 4.0 μA
0.16 % + 20 μA
0.10 % + 20 μA
0.07 % + 20 μA
0.12 % + 50 μA
0.24 % + 100 µA
0.47 % + 200 µA
Multiproduct
calibrator | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 5 of 18
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Generate
(cont)
(0.33 to 1.0999) A
(1.1 to 2.9999) A
(3 to 10.9999) A
(11 to 20.5) A
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
(100 to 1000) Hz
(1 to 5) kHz
(45 to 100) Hz
(100 to 1000) Hz
(1 to 5) kHz
0.19 % + 0.1 mA
0.08 % + 0.1 mA
0.55 % + 1 mA
3.2 % + 5 mA
0.15 % + 0.1 mA
0.06 % + 0.1 mA
0.52 % + 1 mA
2.2 % + 5 mA
0.10 % + 2 mA
0.12 % + 2 mA
2.4 % + 2 mA
0.14 % + 5 mA
0.16 % + 5 mA
2.3 % + 5 mA
Multiproduct
calibrator
AC Current-
Clamp-On Ammeter
(Non-Toroidal Type)
20 A
150 A
550 A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
0.37 A
0.45 A
1.8 A
2.4 A
4.2 A
Multiproduct
calibrator with coil
AC Current –
Clamp-On Ammeter
(Toroidal & Other Types
of Clamp)
(15 to 150) A
(150 to 550) A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
0.37 A
0.37 A
4.1 A
Multiproduct
calibrator with coil | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 6 of 18
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Measure
(0 to 10) mV
(10 to 100) mV
(10 to 100) mV
(1 to 10) V
(10 to 100) V
100 V to 1 kV
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 10) kHz
0.05 % + 2 μV
0.03 % + 1.0 μV
0.04 % + 1.0 μV
0.13 % + 1.0 μV
0.51 % + 1.0 μV
4.0 % + 1.8 μV
0.014 % + 4.0 μV
0.008 % + 2.0 μV
0.015 % + 2.0 μV
0.045 % + 2.0 μV
0.085 % + 2.0 μV
0.28 % + 10 μV
0.011 % + 40 μV
0.008 % + 20 μV
0.016 % + 20 μV
0.032 % + 20 μV
0.07 % + 20 μV
0.30 % + 100 μV
0.012 % + 500 μV
0.008 % + 200 μV
0.015 % + 200 μV
0.030 % + 200 μV
0.07 % + 200 μV
0.020 % + 4.0 mV
0.020 % + 2.0 μV
0.022 % + 2.0 μV
0.04 % + 30 mV
0.04 % + 12 mV
0.06 % + 12 mV
Reference multimeter | ||
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 7 of 18
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Measure
3
Up to 100 μA
100 μA to 100 mA
100 mA to 1 A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
0.42 % + 0.02 μA
0.15 % + 0.05 μA
0.07 % + 0.02 μA
0.40 % + 20 μA
0.15 % + 20 μA
0.07 % + 30 μA
0.05 % + 20 μA
0.42 % + 200 μA
0.15 % + 200 μA
0.10 % + 200 μA
0.12 % + 200 μA
Reference
multimeter
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Resistance – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(330 to 1100) Ω
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(330 to 1100) kΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
0.011 % + 8 mΩ
0.012 % + 15 mΩ
0.007 % + 15 mΩ
0.007 % + 15 mΩ
0.007 % + 60 mΩ
0.007 % + 60 mΩ
0.007 % + 600 mΩ
0.007 % + 600 mΩ
0.009 % + 6 Ω
0.010 % + 6 Ω
0.013 % + 55 Ω
0.012 % + 55 Ω
0.05 % + 550 Ω
0.08 % + 550 Ω
0.39 % + 5.5 kΩ
0.39 % + 17 kΩ
1.5 % + 60 kΩ
Multiproduct
calibrator
Resistance –Measure
(1 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
0.0018 % + 0.45 mΩ
0.0012 % + 0.25 mΩ
0.0011 % + 0.35 mΩ
0.0012 % + 5.0 mΩ
0.0012 % + 25 mΩ
0.0015 % + 2 Ω
0.005 % + 50 Ω
0.055 % + 1.0 kΩ
0.5 % + 10 kΩ
Reference
multimeter | to 100 MΩ |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 8 of 18
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Capacitance – Generate
(220 to 400) pF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(330 to 1100) nF
(1.1 to 3.3) μF
(3.3 to 11) μF
(11 to 33) μF
(33 to 110) μF
(110 to 330) μF
(330 to 1100) μF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
3.9 % + 10 pF
1.2 % + 0.01 nF
0.63 % + 0.01 nF
0.28 % + 0.1 nF
0.22 % + 0.1 nF
0.20 % + 0.1 nF
0.27 % + 0.3 nF
0.20 % + 0.3 nF
0.66 % + 3 nF
0.28 % + 10 nF
0.40 % + 30 nF
0.44 % + 100 nF
0.45 % + 300 nF
0.24 % + 3 μF
0.09 % + 10 μF
0.43 % + 10 μF
0.98 % + 30 μF
1.9 % + 100 μF
Multiproduct
calibrator | ||
| 9 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 9 of 18
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples
3 –
Type B
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.34 °C
0.27 °C
0.24 °C
0.26 °C
0.39 °C
0.13 °C
0.11 °C
0.13 °C
0.17 °C
0.21 °C
0.13 °C
0.11 °C
0.14 °C
0.18 °C
0.26 °C
0.13 °C
0.13 °C
0.11 °C
0.18 °C
0.31 °C
0.17 °C
0.15 °C
0.14 °C
0.21 °C
0.44 °C
0.27 °C
0.26 °C
0.31 °C
0.37 °C
0.28 °C
0.29 °C
0.36 °C
0.49 °C
0.19 °C
0.13 °C
0.11 °C
Multiproduct
calibrator | to 1820 °C |
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 10 of 18
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
RTD –
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.05 °C
0.05 °C
0.06 °C
0.08 °C
0.08 °C
0.10 °C
0.18 °C
0.05 °C
0.05 °C
0.06 °C
0.08 °C
0.08 °C
0.10 °C
0.20 °C
0.04 °C
0.05 °C
0.06 °C
0.06 °C
0.07 °C
0.08 °C
0.09 °C
0.18 °C
0.04 °C
0.04 °C
0.04 °C
0.05 °C
0.10 °C
0.11 °C
0.11 °C
0.13 °C
0.04 °C
0.05 °C
0.05 °C
0.06 °C
0.07 °C
0.07 °C
0.08 °C
0.09 °C
Multiproduct
calibrator | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 11 of 18
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
RTD – (cont)
Pt 385, 1000 Ω
Pt Ni 385, 120 Ω
(Ni 120)
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.04 °C
0.04 °C
0.04 °C
0.05 °C
0.06 °C
0.06 °C
0.06 °C
0.18 °C
0.07 °C
0.07 °C
0.11 °C
0.23 °C
Multiproduct
calibrator
IV. Mechanical
Parameter/Equipment
Range
CMC
2, 6, 8 (±)
Comments
Pressure
3 – Measuring
Equipment
Pneumatic
Hydraulic
(0 to 500) inꞏH₂O
(-400 to -1) inꞏH₂O
(3 to 50) psig
(> 50 to 500) psi
Up to 1000 psi
(1000 to 10 000) psi
0.007 %
0.007 %
0.005 psig
0.01 %
0.52 psi
5.2 psi
Digital pressure
calibrator
Deadweight tester
Digital pressure
indicators
Negative Pressure
3
(Pneumatic) – Measuring
Equipment
(-30 to -3.0) inꞏHg
(-2 to -1) inꞏHg
0.01 %
0.025 %
Deadweight tester | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 12 of 18
Parameter/Equipment
Range
CMC2 (±)
Comments
Balances/Scales
3
1 mg
2 mg
5 mg
10 mg
20 mg
50 mg
100 mg
200 mg
500 mg
1 g
2 g
5 g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
2 kg
5 kg
10 kg
20 kg
0.0016 mg
0.0016 mg
0.0016 mg
0.0017 mg
0.0016 mg
0.0016 mg
0.0016 mg
0.0016 mg
0.0017 mg
0.012 mg
0.012 mg
0.0081 mg
0.013 mg
0.014 mg
0.016 mg
0.023 mg
0.028 mg
0.13 mg
0.33 mg
0.52 mg
0.9 mg
1.7 mg
9.5 mg
Standard weights
High Capacity Scales3
(20 to 100) kg
(100 to 500) kg
(500 to 1000) kg
3.6 g
31 g
38 g
Standard weights
Mass –
Fixed Points
25 kg
20 kg
10 kg
5 kg
3 kg
2 kg
1 kg
11 mg
11 mg
3.4 mg
3.0 mg
2.8 mg
2.8 mg
2.3 mg
Standard weights using
single substitution
Mass – High Capacity
Fixed Points
500 kg
250 kg
100 kg
50 kg
200 mg
240 mg
270 mg
330 mg
Standard weights using
single substitution | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 13 of 18
Parameter/Equipment
Range
CMC2 (±)
Comments
Mass – High Precision
Fixed Points
20 kg
10 kg
5 kg
2 kg
1 kg
500 g
200 g
100 g
50 g
20 g
10 g
5 g
2 g
1 g
500 mg
200 mg
100 mg
50 mg
20 mg
10 mg
5 mg
2 mg
1 mg
6.5 mg
4.2 mg
1.9 mg
0.80 mg
0.12 mg
0.063 mg
0.030 mg
0.016 mg
0.012 mg
7.4 µg
6.9 µg
3.5 µg
2.5 µg
1.5 µg
1.5 µg
1.5 µg
1.5 µg
1.0 µg
1.3 µg
1.1 µg
0.7 µg
1.2 µg
0.76 µg
Echelon I, double
substitution
Mass – High Precision
Fixed Points
20 kg
10 kg
5 kg
2 kg
1 kg
500 g
200 g
100 g
50 g
20 g
10 g
5 g
2 g
1 g
500 mg
200 mg
100 mg
50 mg
7.0 mg
5.7 mg
2.9 mg
0.95 mg
0.17 mg
0.058 mg
0.037 mg
0.028 mg
0.012 mg
8.9 µg
11 µg
3.6 µg
2.9 µg
1.8 µg
1.6 µg
1.9 µg
1.7 µg
2.9 µg
Echelon II, double
substitution | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 14 of 18
Parameter/Equipment
Range
CMC2 (±)
Comments
Mass – High Precision
(cont.)
Fixed Points
20 mg
10 mg
5 mg
2 mg
1 mg
1.8 µg
1.3 µg
0.8 µg
1.4 µg
1.0 µg
Echelon II, double
substitution
Mass – High Precision
Fixed Points
20 kg
10 kg
5 kg
2 kg
1 kg
500 g
200 g
100 g
50 g
20 g
10 g
5 g
2 g
1 g
500 mg
200 mg
100 mg
50 mg
20 mg
10 mg
5 mg
2 mg
1 mg
11 mg
6.9 mg
4.0 mg
3.4 mg
1.8 mg
0.085 mg
0.045 mg
0.035 mg
0.018 mg
0.012 mg
0.015 mg
4.4 µg
2.9 µg
2.0 µg
2.0 µg
2.1 µg
2.0 µg
2.1 µg
2.0 µg
1.6 µg
1.0 µg
1.8 µg
1.0 µg
Echelon III, double
substitution | ||
| 15 | ISO-8655-6 | - | See scope document |
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 16 of 18
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Temperature –
Measuring Equipment
(PRT/RTD Sensors, TC
Sensors, Thermistor Sensor,
Digital Thermometers,
Mechanical Thermometer)
-195 °C
(-80 to -40) °C
(-40 to -20) °C
0.0 °C
(0.0 to 100) °C
(100 to 232) °C
(232 to 420) °C
(420 to 660) °C
0.006 °C
0.009 °C
0.009 °C
0.008 °C
0.009 °C
0.010 °C
0.019 °C
0.021 °C
SPRT (fixed point)
SPRT & temperature
readout
Temperature – Environmental
Measuring Equipment
(5 to 70) °C
0.08 °C
Humidity generator
Temperature – Measure3
(Portable Liquid Baths,
Incubators, Dry Wells, or
Portable Chambers)
(-195 to -80) °C
(-80 to 0) °C
(-40 to 0) °C
(0.0 to 30) °C
(30 to 100) °C
(100 to 157) °C
(157 to 232) °C
(232 to 400) °C
0.05 °C
0.06 °C
0.06 °C
0.07 °C
0.08 °C
0.09 °C
0.10 °C
0.14 °C
PRT probe &
temperature readout
Temperature – Liquid-in-Glass
Thermometers (Partial & Total
Immersion)
(-35 to 50) °C
(51 to 150) °C
(151 to 200) °C
(201 to 250) °C
0.12 °C
0.12 °C
0.12 °C
0.18 °C
Comparison with
SPRT/PRT &
temperature readout
Relative Humidity –
Measuring Equipment
(Humidity Meters, Chart
Recorder, Transmitters)
(10 to 95) % RH
0.51 % RH
Humidity generator
Relative Humidity –
Measure
3
(Environmental Chambers)
(10 to 95) % RH
1.6 % RH
Humidity indicator | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 17 of 18
VI. Time & Frequency
Parameter/Equipment
Range
CMC2 (±)
Comments
Frequency – Generate
50 Hz to 20 MHz
50 Hz to 50 kHz
22 μHz/Hz
82 μHz/Hz
Signal generator
Multiproduct calibrator
Frequency – Measure
30 Hz to 225 MHz
8 μHz/Hz
Frequency counter
Stopwatches & Timers
(0 to 86 400) s
(0 to 86 400) s
0.062 s
0.054 s
Signal generator &
Frequency counter
Timometer
________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the small est uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3
Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calib ration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical length of the device in inches or meters.
5 The measurands stated are generated using the indica ted instrument (see Commen ts). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges indicated.
CMCs are expressed as either a specific value that covers the full range or as a fraction or percent of the
reading plus a fixed floor specification.
6 In the statement of CMC, percentage refers to percent of reading, unless otherwise noted.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 18 | ILAC P-14 | - | - |
| 19 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Caguas Real #100, Alhambra Granada Blvd., Caguas, 00725, Puerto Rico, Caguas, US
18.21294, -66.05588
Open in MapsLabs with overlapping accredited scope in United States
- Project Specialists of Puerto RicoPonce · ~61 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Kimball ElectronicHialeah, FL · ~1,691 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - POMPANO BEACHPompano Beach, FL · ~1,699 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- M & M MetrologyDeerfield Beach, FL · ~1,701 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Miami, FLBoca Raton, FL · ~1,702 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.