United States

Project Specialists of Puerto Rico

Ponce, United States

Visit website
A2LA 4910.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
12
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 12 scope lines.

A2LA certificate 4910.01 · 12 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ASME B89.1.14; ASME B89.1.13-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4910.01) Revised 12/23/2025 Page 2 of 11 Parameter/Equipment Range CMC2, 3 (±) Comments DC Current – Generate Non-Toroidal Clamp (0 to 330) μA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A 0.012 % + 16 nA 0.0077 % + 43 nA 0.0076 % + 0.26 µA 0.0076 % + 3.3 µA 0.015 % + 35 µA 0.028 % + 95 µA 0.038 % + 0.55 mA 0.077 % + 0.85 mA 0.38 % + 17 mA 0.39 % + 0.11 A 0.38 % + 0.4 A Fluke 5522A Fluke 5522A & 50 turn coil DC Current – Measure (0 to 200) μA (0.2 to 2) mA (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A 0.0020 % + 0.51 nA 0.0023 % + 4.6 nA 0.0023 % + 51 nA 0.0076 % + 1 µA 0.017 % + 15 µA 0.039 % + 0.32 mA Fluke 8508A Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.062 % + 4.9 µV 0.012 % + 4.9 µV 0.016 % + 4.9 µV 0.079 % + 4.9 µV 0.27 % + 9.4 µV 0.62 % + 39 µV 0.023 % + 6.6 µV 0.011 % + 6.7 µV 0.013 % + 6.7 µV 0.027 % + 6.5 µV 0.062 % + 25 µV 0.16 % + 54 µV 0.023 % + 39 µV 0.012 % + 46 µV 0.015 % + 47 µV 0.023 % + 39 µV 0.055 % + 96 µV 0.19 % + 0.46 mV Fluke 5522A
3-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4910.01) Revised 12/23/2025 Page 3 of 11 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (cont) (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.045 to 1) kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz 0.023 % + 0.50 mV 0.012 % + 0.46 mV 0.019 % + 0.47 mV 0.027 % + 0.46 mV 0.070 % + 1.2 mV 0.015 % + 1.5 mV 0.016 % + 4.6 mV 0.021 % + 4 mV 0.025 % + 4.1 mV 0.16 % + 39 mV 0.023 % + 8.8 mV 0.019 % + 9.4 mV 0.023 % + 9.2 mV Fluke 5522A AC Voltage – Measure (0 to 200) mV (0.2 to 2) V (2 to 20) V (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 0.027 % + 20 µV 0.020 % + 6.3 µV 0.017 % + 6.3 µV 0.017 % + 3 µV 0.021 % + 6.3 µV 0.050 % + 13 µV 0.11 % + 30 µV 0.024 % + 0.18 mV 0.016 % + 52 µV 0.014 % + 30 µV 0.0068 % + 27 µV 0.010 % + 25 µV 0.020 % + 43 µV 0.050 % + 0.19 mV 0.23 % + 1.9 mV 0.78 % + 19 mV 0.015 % + 1.1 mV 0.010 % + 0.19 mV 0.0085 % + 0.19 mV 0.0070 % + 0.19 mV 0.010 % + 0.19 mV 0.020 % + 0.39 mV 0.050 % + 1.9 mV 0.23 % + 19 mV 0.78 % + 0.19 V Fluke 8508A
-
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4910.01) Revised 12/23/2025 Page 4 of 11 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Measure (cont) (20 to 200) V (200 to 1050) V (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 10) Hz (10 to 40) Hz (0.040 to 10) kHz (10 to 30) kHz (30 to 100) kHz 0.015 % + 11 mV 0.010 % + 1.9 mV 0.0085 % + 1.9 mV 0.0070 % + 1.9 mV 0.010 % + 1.9 mV 0.020 % + 3.9 mV 0.050 % + 19 mV 0.23 % + 0.19 V 0.78 % + 1.9 V 0.015 % + 62 mV 0.011 % + 19 mV 0.011 % + 19 mV 0.021 % + 39 mV 0.054 % + 0.19 V Fluke 8508A AC Current – Generate (29 to 330) μA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.16 % + 78 nA 0.12 % + 77 nA 0.098 % + 78 nA 0.23 % + 0.12 µA 0.62 % + 0.16 µA 1.2 % + 0.31 µA 0.16 % + 0.12 µA 0.098 % + 0.11 µA 0.078 % + 0.12 µA 0.16 % + 0.15 µA 0.40 % + 0.19 µA 0.78 % + 0.46 µA 0.14 % + 1.5 µA 0.071 % + 1.5 µA 0.034 % + 1.5 µA 0.064 % + 1.5 µA 0.16 % + 2.3 µA 0.32 % + 3 µA 0.14 % + 16 µA 0.071 % + 16 µA 0.033 % + 16 µA 0.079 % + 39 µA 0.16 % + 77 µA 0.32 % + 0.15 mA Fluke 5522A
5-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4910.01) Revised 12/23/2025 Page 5 of 11 Parameter/Range Frequency CMC2, 3 (±) Comments AC Current – Generate (cont) (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A Clamp On Meters – Toroidal (10 to 16.5) A (16.5 to 150) A (150 to 1025) A Clamp On Meters – Non-Toroidal (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.14 % + 80 µA 0.04 % + 82 µA 0.47 % + 0.77 mA 1.9 % + 3.9 mA 0.14 % + 72 µA 0.058 % + 35 µA 0.47 % + 0.75 mA 1.9 % + 3.9 mA 0.051 % + 1.6 mA 0.08 % + 1.6 mA 2.3 % + 1.5 mA 0.095 % + 3.9 mA 0.12 % + 3.9 mA 2.3 % + 3.9 mA 0.012 % + 0.6 A 0.10 % + 0.59 A 0.080 % + 0.59 A 0.42 % + 0.54 A 0.19 % + 0.45 A 0.52 % + 1.3 A 0.057 % + 0.6 A 0.17 % + 0.59 A 0.29 % + 0.61 A 0.64 % + 0.58 A 0.41 % + 0.87 A 0.68 % + 1.6 A Fluke 5522A Fluke 5522A & 50 turn coil Fluke 5522A & 50 turn coil
See scope document
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4910.01) Revised 12/23/2025 Page 6 of 11 Parameter/Range Frequency CMC2, 3 (±) Comments AC Current – Measure (0 to 200) μA (0.2 to 2) mA (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A (1 to 10) Hz (0.01 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (0.01 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (0.01 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (0.01 to 10) kHz (10 to 30) kHz (0.01 to 2) kHz (2 to 10) kHz (10 to 30) kHz (0.01 to 2) kHz (2 to 10) kHz 0.078 % + 30 nA 0.078 % + 30 nA 0.10 % + 30 nA 0.51 % + 30 nA 0.051 % + 0.30 µA 0.047 % + 0.30 µA 0.10 % + 0.30 µA 0.51 % + 0.30 µA 0.051 % + 3 µA 0.047 % + 3 µA 0.10 % + 3 µA 0.51 % + 3 µA 0.051 % + 30 µA 0.046 % + 30 µA 0.094 % + 30 µA 0.056 % + 0.20 mA 0.068 % + 0.25 mA 0.22 % + 0.39 mA 0.071 % + 1.9 mA 0.19 % + 1.9 mA Fluke 8508A Resistance – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 0.0031 % + 7.8 mΩ 0.0023 % + 12 mΩ 0.0022 % + 12 mΩ 0.0022 % + 15 mΩ 0.0022 % + 15 mΩ 0.0022 % + 0.15 Ω 0.0023 % + 0.77 Ω 0.0022 % + 0.78 Ω 0.0023 % + 0.77 Ω 0.0025 % + 7.7 Ω 0.0025 % + 8.0 Ω 0.0048 % + 0.12 kΩ 0.010 % + 0.19 kΩ 0.020 % + 1.9 kΩ 0.04 % + 2.3 kΩ 0.23 % + 78 kΩ 1.2 % + 0.39 MΩ Fluke 5522A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4910.01) Revised 12/23/2025 Page 7 of 11 Parameter/Equipment Range CMC2, 3 (±) Comments Resistance – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω (0.2 to 2) kΩ (2 to 20) kΩ (20 to 200) kΩ (0.2 to 2) MΩ (2 to 20) MΩ (20 to 200) MΩ 0.0015 % + 9.3 µΩ 0.000 85 % + 31 µΩ 0.000 77 % + 48 µΩ 0.000 78 % + 0.47 mΩ 0.000 78 % + 4.7 mΩ 0.000 78 % + 47 mΩ 0.000 94 % + 0.91 Ω 0.0019 % + 93 Ω 0.012 % + 9.3 kΩ Fluke 8508A Capacitance – Generate (220 to 399.9) pF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) μF (1.1 to 3.3) μF (3.3 to 11) μF (11 to 33) μF (33 to 110) μF (110 to 330) μF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 0.37 % + 8 pF 0.37 % + 8.1 pF 0.39 % + 7.8 pF 0.20 % + 8.3 pF 0.20 % + 8.0 pF 0.18 % + 31 pF 0.19 % + 56 pF 0.19 % + 0.9 nF 0.20 % + 2.5 nF 0.20 % + 8.8 nF 0.31 % + 25 nF 0.35 % + 91 nF 0.35 % + 0.27 µF 0.35 % + 0.89 µF 0.45 % + 3 µF 0.45 % + 10 µF 0.75 % + 30 µF 1.1 % + 0.10 mF Fluke 5522A Electrical Simulation of Thermocouple & Thermocouple Indicating Devices – Measure & Generate Type B Type C (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C 0.34 °C 0.27 °C 0.24 °C 0.25 °C 0.24 °C 0.21 °C 0.25 °C 0.39 °C 0.65 °C Fluke 5522A
8-thermocouple
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4910.01) Revised 12/23/2025 Page 8 of 11 Parameter/Equipment Range CMC2, 3 (±) Comments Electrical Simulation of Thermocouple & Thermocouple Indicating Devices – Measure & Generate (cont) Type E Type J Type K Type N Type R Type S Type T Type U (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (250 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1000 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-200 to 0) °C (0 to 600) °C 0.39 °C 0.13 °C 0.12 °C 0.13 °C 0.17 °C 0.21 °C 0.13 °C 0.12 °C 0.14 °C 0.18 °C 0.26 °C 0.15 °C 0.13 °C 0.21 °C 0.31 °C 0.31 °C 0.18 °C 0.15 °C 0.15 °C 0.21 °C 0.45 °C 0.27 °C 0.26 °C 0.31 °C 0.38 °C 0.29 °C 0.29 °C 0.35 °C 0.47 °C 0.19 °C 0.13 °C 0.12 °C 0.44 °C 0.21 °C Fluke 5522A
See scope document
9-RTD Indicating Devices
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4910.01) Revised 12/23/2025 Page 9 of 11 Parameter/Equipment Range CMC2, 3 (±) Comments Electrical Simulation of RTD Indicating Devices – Generate Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.039 °C 0.039 °C 0.054 °C 0.070 °C 0.078 °C 0.093 °C 0.18 °C 0.039 °C 0.039 °C 0.054 °C 0.070 °C 0.078 °C 0.093 °C 0.19 °C 0.031 °C 0.039 °C 0.047 °C 0.054 °C 0.062 °C 0.070 °C 0.078 °C 0.18 °C 0.031 °C 0.031 °C 0.031 °C 0.037 °C 0.094 °C 0.10 °C 0.11 °C 0.12 °C 0.037 °C 0.042 °C 0.042 °C 0.049 °C 0.064 °C 0.043 °C 0.078 °C 0.09 °C Fluke 5522A
See scope document
10-RTD Indicating Devices; Torque Wrenches & Tools; Vacuum Gauges; Pressure Gauges
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4910.01) Revised 12/23/2025 Page 10 of 11 Parameter/Equipment Range CMC2, 3 (±) Comments Electrical Simulation of RTD Indicating Devices – Generate (cont) Pt 385, 1000 Ω PtNi 385, 120 Ω Cu 427, 10 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-100 to 260) °C 0.024 °C 0.024 °C 0.032 °C 0.038 °C 0.053 °C 0.06 °C 0.06 °C 0.18 °C 0.062 °C 0.062 °C 0.11 °C 0.23 °C Fluke 5522A III. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comments Torque – Torque Wrenches & Tools (4 to 50) lbf-in (30 to 400) lbf-in (80 to 1000) lbf-in (20 to 250) lbf-ft 0.33 % + 0.0016 lbf-in 0.33 % + 0.0066 lbf-in 0.32 % + 0.05 lbf-in 0.29 % + 0.086 lbf-ft CDI 5000-ST with 2000-400-02 4 in 1 transducer Pressure Measure – Vacuum Gauges Pressure Gauges (-14 to 0) psig (0 to 300) psig (300 to 1000) psig (1000 to 10 000) psig 0.07 psig 0.071 psig 0.25 psig 2.7 psig Crystal 300PSIXP21-S2 Crystal 300PSIXP21-S2 Crystal 1KPSIXP21-S2 Crystal 10KPSIXP21-S2
See scope document
11-Frequency
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4910.01) Revised 12/23/2025 Page 11 of 11 IV. Time & Frequency Parameter/Equipment Range CMC2, 4 (±) Comments Frequency – Measuring Equipment (0.01 to 119.99) Hz (120 to 1199.9) Hz (1.2 to 11.999) kHz (12 to 119.99) kHz (120 to 1199.9) kHz (1.2 to 2) MHz 5.8 mHz 58 mHz 0.58 Hz 5.8 Hz 58 Hz 580 Hz Fluke 5522A Frequency – Measure (5 to 1000) Hz (1 to 1000) kHz (1 to 2) MHz 1.1 mHz 0.5 Hz 1.0 Hz Keysight 53230A Stopwatches Up to 24 hrs 0.066 s/day Helmut Klein Timometer 4500 ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6L is the numerical value of the nominal length of the device measured in inches.
See scope document
12ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.