Mentor Technical Group Metrology

Caguas Real #100, Alhambra Granada Blvd., Caguas, 00725, Puerto Rico, Caguas, United States

Visit website
A2LA 3595.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
19
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 19 scope lines.

A2LA certificate 3595.01 · 19 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 2 of 18 Parameter/Equipment Range CMC2, 4 (±) Comments Calipers 3 (cont) Up to 100 mm (6 + 2L) µm Gage blocks Micrometers 3 Up to 1.0 in (44 + 4.8L) µin Gage blocks III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC 2, 5 (±) Comments DC Voltage – Generate (0 to 329.999) mV (0.33 to 3.299) V (3.3 to 32.999) V (33 to 329.999) V (330 to 1020) V 22 μV/V + 1 μV 15 μV/V + 2 μV 11 μV/V + 20 μV 28 μV/V + 180 μV 0.018 mV/V + 2.7 mV Multiproduct calibrator DC Voltage – Measure Up to 100 mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 12 μV/V + 0.3 μV 9.0 μV/V + 0.3 μV 8.5 μV/V + 0.5 μV 11 μV/V + 30 μV 13 μV/V + 100 μV Reference multimeter DC Current – Generate (0 to 329.9) µA (0.3 to 3.29) mA (3.3 to 32.9) mA (33 to 329.9) mA (330 mA to 2.9) A (3 to 11) A (11 to 20.5) A 0.015 % + 0.02 μA 0.010 % + 0.05 μA 0.010 % + 0.25 μA 0.010 % + 2.5 μA 0.025 % + 44 μA 0.05 % + 330 μA 0.1 % + 750 μA Multiproduct calibrator DC Current – Clamp-On Ammeter (Non-Toroidal Type) (15 to 150) A (150 to 550) A 1.3 A 3.4 A Multiproduct calibrator with coil DC Current – Clamp-On Ammeter (Toroidal & Other Types of Clamp) (15 to 150) A (150 to 550) A 1.3 A 3.4 A Multiproduct calibrator with coil
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 3 of 18 Parameter/Equipment Range CMC2, 5 (±) Comments DC Current – Measure 100 nA to 10 µA (10 to 100) µA 100 µA to 10 mA (10 to 100) mA 100 mA to 1 A 25 µA/A + 0.12 nA 18 µA/A + 0.8 nA 22 µA/A + 55 nA 38 µA/A + 15 µA 0.014 % + 12 µA Reference multimeter Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate (1 to 32.999) mV (33 to 329.999) mV 330 mV to 3.2999 V (3.3 to 32.999) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.08 % + 6 μV 0.03 % + 6 μV 0.03 % + 6 μV 0.09 % + 6 μV 0.3 % + 12 μV 0.74 % + 50 μV 0.03 % + 8 μV 0.01 % + 8 μV 0.01 % + 8 μV 0.03 % + 32 μV 0.07 % + 32 μV 0.17 % + 70 μV 0.03 % + 50 μV 0.01 % + 60 μV 0.02 % + 60 μV 0.02 % + 50 μV 0.02 % + 130 μV 0.2 % + 600 µV 0.02 % + 0.65 mV 0.01 % + 0.6 mV 0.02 % + 0.6 mV 0.03 % + 0.6 mV 0.07 % + 1.6 mV Multiproduct calibrator
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 4 of 18 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate (cont) (33 to 329.999) V (330 to 1000) V 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.02 % + 2 mV 0.02 % + 6 mV 0.02 % + 6 mV 0.03 % + 6 mV 0.17 % + 50 mV 0.02 % + 10 mV 0.02 % + 10 mV 0.02 % + 10 mV Multiproduct calibrator AC Current – Generate (29 to 329.99) µA (0.33 to 3.2999) mA (3.3 to 32.9999) mA (33 to 329.99) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.29 % + 0.1 μA 0.27 % + 0.1 μA 0.25 % + 0.1 μA 0.36 % + 0.15 μA 0.76 % + 0.2 μA 1.5 % + 0.4 μA 0.18 % + 0.15 μA 0.12 % + 0.15 μA 0.10 % + 0.15 μA 0.17 % + 0.2 μA 0.41 % + 0.3 μA 0.81 % + 0.6 μA 0.16 % + 2.0 μA 0.09 % + 2.0 μA 0.06 % + 2.0 μA 0.08 % + 2.0 μA 0.18 % + 2.0 μA 0.34 % + 4.0 μA 0.16 % + 20 μA 0.10 % + 20 μA 0.07 % + 20 μA 0.12 % + 50 μA 0.24 % + 100 µA 0.47 % + 200 µA Multiproduct calibrator
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 5 of 18 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate (cont) (0.33 to 1.0999) A (1.1 to 2.9999) A (3 to 10.9999) A (11 to 20.5) A (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (100 to 1000) Hz (1 to 5) kHz (45 to 100) Hz (100 to 1000) Hz (1 to 5) kHz 0.19 % + 0.1 mA 0.08 % + 0.1 mA 0.55 % + 1 mA 3.2 % + 5 mA 0.15 % + 0.1 mA 0.06 % + 0.1 mA 0.52 % + 1 mA 2.2 % + 5 mA 0.10 % + 2 mA 0.12 % + 2 mA 2.4 % + 2 mA 0.14 % + 5 mA 0.16 % + 5 mA 2.3 % + 5 mA Multiproduct calibrator AC Current- Clamp-On Ammeter (Non-Toroidal Type) 20 A 150 A 550 A (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz 0.37 A 0.45 A 1.8 A 2.4 A 4.2 A Multiproduct calibrator with coil AC Current – Clamp-On Ammeter (Toroidal & Other Types of Clamp) (15 to 150) A (150 to 550) A (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz 0.37 A 0.37 A 4.1 A Multiproduct calibrator with coil
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 6 of 18 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure (0 to 10) mV (10 to 100) mV (10 to 100) mV (1 to 10) V (10 to 100) V 100 V to 1 kV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 10) kHz 0.05 % + 2 μV 0.03 % + 1.0 μV 0.04 % + 1.0 μV 0.13 % + 1.0 μV 0.51 % + 1.0 μV 4.0 % + 1.8 μV 0.014 % + 4.0 μV 0.008 % + 2.0 μV 0.015 % + 2.0 μV 0.045 % + 2.0 μV 0.085 % + 2.0 μV 0.28 % + 10 μV 0.011 % + 40 μV 0.008 % + 20 μV 0.016 % + 20 μV 0.032 % + 20 μV 0.07 % + 20 μV 0.30 % + 100 μV 0.012 % + 500 μV 0.008 % + 200 μV 0.015 % + 200 μV 0.030 % + 200 μV 0.07 % + 200 μV 0.020 % + 4.0 mV 0.020 % + 2.0 μV 0.022 % + 2.0 μV 0.04 % + 30 mV 0.04 % + 12 mV 0.06 % + 12 mV Reference multimeter
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 7 of 18 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Measure 3 Up to 100 μA 100 μA to 100 mA 100 mA to 1 A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz 0.42 % + 0.02 μA 0.15 % + 0.05 μA 0.07 % + 0.02 μA 0.40 % + 20 μA 0.15 % + 20 μA 0.07 % + 30 μA 0.05 % + 20 μA 0.42 % + 200 μA 0.15 % + 200 μA 0.10 % + 200 μA 0.12 % + 200 μA Reference multimeter Parameter/Equipment Range CMC2, 5 (±) Comments Resistance – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (330 to 1100) Ω (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (330 to 1100) kΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 0.011 % + 8 mΩ 0.012 % + 15 mΩ 0.007 % + 15 mΩ 0.007 % + 15 mΩ 0.007 % + 60 mΩ 0.007 % + 60 mΩ 0.007 % + 600 mΩ 0.007 % + 600 mΩ 0.009 % + 6 Ω 0.010 % + 6 Ω 0.013 % + 55 Ω 0.012 % + 55 Ω 0.05 % + 550 Ω 0.08 % + 550 Ω 0.39 % + 5.5 kΩ 0.39 % + 17 kΩ 1.5 % + 60 kΩ Multiproduct calibrator Resistance –Measure (1 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 0.0018 % + 0.45 mΩ 0.0012 % + 0.25 mΩ 0.0011 % + 0.35 mΩ 0.0012 % + 5.0 mΩ 0.0012 % + 25 mΩ 0.0015 % + 2 Ω 0.005 % + 50 Ω 0.055 % + 1.0 kΩ 0.5 % + 10 kΩ Reference multimeter
to 100 MΩ
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 8 of 18 Parameter/Equipment Range CMC2, 5 (±) Comments Capacitance – Generate (220 to 400) pF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (330 to 1100) nF (1.1 to 3.3) μF (3.3 to 11) μF (11 to 33) μF (33 to 110) μF (110 to 330) μF (330 to 1100) μF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 3.9 % + 10 pF 1.2 % + 0.01 nF 0.63 % + 0.01 nF 0.28 % + 0.1 nF 0.22 % + 0.1 nF 0.20 % + 0.1 nF 0.27 % + 0.3 nF 0.20 % + 0.3 nF 0.66 % + 3 nF 0.28 % + 10 nF 0.40 % + 30 nF 0.44 % + 100 nF 0.45 % + 300 nF 0.24 % + 3 μF 0.09 % + 10 μF 0.43 % + 10 μF 0.98 % + 30 μF 1.9 % + 100 μF Multiproduct calibrator
9--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 9 of 18 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples 3 – Type B Type E Type J Type K Type N Type R Type S Type T (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.34 °C 0.27 °C 0.24 °C 0.26 °C 0.39 °C 0.13 °C 0.11 °C 0.13 °C 0.17 °C 0.21 °C 0.13 °C 0.11 °C 0.14 °C 0.18 °C 0.26 °C 0.13 °C 0.13 °C 0.11 °C 0.18 °C 0.31 °C 0.17 °C 0.15 °C 0.14 °C 0.21 °C 0.44 °C 0.27 °C 0.26 °C 0.31 °C 0.37 °C 0.28 °C 0.29 °C 0.36 °C 0.49 °C 0.19 °C 0.13 °C 0.11 °C Multiproduct calibrator
to 1820 °C
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 10 of 18 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of RTD – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.05 °C 0.05 °C 0.06 °C 0.08 °C 0.08 °C 0.10 °C 0.18 °C 0.05 °C 0.05 °C 0.06 °C 0.08 °C 0.08 °C 0.10 °C 0.20 °C 0.04 °C 0.05 °C 0.06 °C 0.06 °C 0.07 °C 0.08 °C 0.09 °C 0.18 °C 0.04 °C 0.04 °C 0.04 °C 0.05 °C 0.10 °C 0.11 °C 0.11 °C 0.13 °C 0.04 °C 0.05 °C 0.05 °C 0.06 °C 0.07 °C 0.07 °C 0.08 °C 0.09 °C Multiproduct calibrator
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 11 of 18 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of RTD – (cont) Pt 385, 1000 Ω Pt Ni 385, 120 Ω (Ni 120) Cu 427, 10 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-100 to 260) °C 0.04 °C 0.04 °C 0.04 °C 0.05 °C 0.06 °C 0.06 °C 0.06 °C 0.18 °C 0.07 °C 0.07 °C 0.11 °C 0.23 °C Multiproduct calibrator IV. Mechanical Parameter/Equipment Range CMC 2, 6, 8 (±) Comments Pressure 3 – Measuring Equipment Pneumatic Hydraulic (0 to 500) inꞏH₂O (-400 to -1) inꞏH₂O (3 to 50) psig (> 50 to 500) psi Up to 1000 psi (1000 to 10 000) psi 0.007 % 0.007 % 0.005 psig 0.01 % 0.52 psi 5.2 psi Digital pressure calibrator Deadweight tester Digital pressure indicators Negative Pressure 3 (Pneumatic) – Measuring Equipment (-30 to -3.0) inꞏHg (-2 to -1) inꞏHg 0.01 % 0.025 % Deadweight tester
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 12 of 18 Parameter/Equipment Range CMC2 (±) Comments Balances/Scales 3 1 mg 2 mg 5 mg 10 mg 20 mg 50 mg 100 mg 200 mg 500 mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 20 kg 0.0016 mg 0.0016 mg 0.0016 mg 0.0017 mg 0.0016 mg 0.0016 mg 0.0016 mg 0.0016 mg 0.0017 mg 0.012 mg 0.012 mg 0.0081 mg 0.013 mg 0.014 mg 0.016 mg 0.023 mg 0.028 mg 0.13 mg 0.33 mg 0.52 mg 0.9 mg 1.7 mg 9.5 mg Standard weights High Capacity Scales3 (20 to 100) kg (100 to 500) kg (500 to 1000) kg 3.6 g 31 g 38 g Standard weights Mass – Fixed Points 25 kg 20 kg 10 kg 5 kg 3 kg 2 kg 1 kg 11 mg 11 mg 3.4 mg 3.0 mg 2.8 mg 2.8 mg 2.3 mg Standard weights using single substitution Mass – High Capacity Fixed Points 500 kg 250 kg 100 kg 50 kg 200 mg 240 mg 270 mg 330 mg Standard weights using single substitution
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 13 of 18 Parameter/Equipment Range CMC2 (±) Comments Mass – High Precision Fixed Points 20 kg 10 kg 5 kg 2 kg 1 kg 500 g 200 g 100 g 50 g 20 g 10 g 5 g 2 g 1 g 500 mg 200 mg 100 mg 50 mg 20 mg 10 mg 5 mg 2 mg 1 mg 6.5 mg 4.2 mg 1.9 mg 0.80 mg 0.12 mg 0.063 mg 0.030 mg 0.016 mg 0.012 mg 7.4 µg 6.9 µg 3.5 µg 2.5 µg 1.5 µg 1.5 µg 1.5 µg 1.5 µg 1.0 µg 1.3 µg 1.1 µg 0.7 µg 1.2 µg 0.76 µg Echelon I, double substitution Mass – High Precision Fixed Points 20 kg 10 kg 5 kg 2 kg 1 kg 500 g 200 g 100 g 50 g 20 g 10 g 5 g 2 g 1 g 500 mg 200 mg 100 mg 50 mg 7.0 mg 5.7 mg 2.9 mg 0.95 mg 0.17 mg 0.058 mg 0.037 mg 0.028 mg 0.012 mg 8.9 µg 11 µg 3.6 µg 2.9 µg 1.8 µg 1.6 µg 1.9 µg 1.7 µg 2.9 µg Echelon II, double substitution
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 14 of 18 Parameter/Equipment Range CMC2 (±) Comments Mass – High Precision (cont.) Fixed Points 20 mg 10 mg 5 mg 2 mg 1 mg 1.8 µg 1.3 µg 0.8 µg 1.4 µg 1.0 µg Echelon II, double substitution Mass – High Precision Fixed Points 20 kg 10 kg 5 kg 2 kg 1 kg 500 g 200 g 100 g 50 g 20 g 10 g 5 g 2 g 1 g 500 mg 200 mg 100 mg 50 mg 20 mg 10 mg 5 mg 2 mg 1 mg 11 mg 6.9 mg 4.0 mg 3.4 mg 1.8 mg 0.085 mg 0.045 mg 0.035 mg 0.018 mg 0.012 mg 0.015 mg 4.4 µg 2.9 µg 2.0 µg 2.0 µg 2.1 µg 2.0 µg 2.1 µg 2.0 µg 1.6 µg 1.0 µg 1.8 µg 1.0 µg Echelon III, double substitution
15ISO-8655-6-See scope document
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 16 of 18 V. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Temperature – Measuring Equipment (PRT/RTD Sensors, TC Sensors, Thermistor Sensor, Digital Thermometers, Mechanical Thermometer) -195 °C (-80 to -40) °C (-40 to -20) °C 0.0 °C (0.0 to 100) °C (100 to 232) °C (232 to 420) °C (420 to 660) °C 0.006 °C 0.009 °C 0.009 °C 0.008 °C 0.009 °C 0.010 °C 0.019 °C 0.021 °C SPRT (fixed point) SPRT & temperature readout Temperature – Environmental Measuring Equipment (5 to 70) °C 0.08 °C Humidity generator Temperature – Measure3 (Portable Liquid Baths, Incubators, Dry Wells, or Portable Chambers) (-195 to -80) °C (-80 to 0) °C (-40 to 0) °C (0.0 to 30) °C (30 to 100) °C (100 to 157) °C (157 to 232) °C (232 to 400) °C 0.05 °C 0.06 °C 0.06 °C 0.07 °C 0.08 °C 0.09 °C 0.10 °C 0.14 °C PRT probe & temperature readout Temperature – Liquid-in-Glass Thermometers (Partial & Total Immersion) (-35 to 50) °C (51 to 150) °C (151 to 200) °C (201 to 250) °C 0.12 °C 0.12 °C 0.12 °C 0.18 °C Comparison with SPRT/PRT & temperature readout Relative Humidity – Measuring Equipment (Humidity Meters, Chart Recorder, Transmitters) (10 to 95) % RH 0.51 % RH Humidity generator Relative Humidity – Measure 3 (Environmental Chambers) (10 to 95) % RH 1.6 % RH Humidity indicator
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3595.01) Revised 10/03/2025 Page 17 of 18 VI. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Frequency – Generate 50 Hz to 20 MHz 50 Hz to 50 kHz 22 μHz/Hz 82 μHz/Hz Signal generator Multiproduct calibrator Frequency – Measure 30 Hz to 225 MHz 8 μHz/Hz Frequency counter Stopwatches & Timers (0 to 86 400) s (0 to 86 400) s 0.062 s 0.054 s Signal generator & Frequency counter Timometer ________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the small est uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calib ration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical length of the device in inches or meters. 5 The measurands stated are generated using the indica ted instrument (see Commen ts). This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction or percent of the reading plus a fixed floor specification. 6 In the statement of CMC, percentage refers to percent of reading, unless otherwise noted. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
18ILAC P-14--
19ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.