Cleveland Specialty Inspection Services
8562 East Avenue, 44060, Mentor, OH, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Cleveland Specialty Inspection Services?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 3039.01Active
Accredited standards
7Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
ISO 594Name not checked yet
ISO 594/1 3; ISO 80369; ISO 8637-2; ISO 5356-1 Luer Tapered Plugs5; ISO 5356-1 Luer Ref Conical Fitting5
ISO 594/1 Fig 4; ISO 80369 ___________________________________________ 1; ISO 80369-2; ISO 80369-3; ISO 80369-6
ISO 5356-1Anaesthetic and respiratory equipment - Conical connectors - Part 1: Cones and sockets
ISO 594/1 3; ISO 80369; ISO 8637-2; ISO 5356-1 Luer Tapered Plugs5; ISO 5356-1 Luer Ref Conical Fitting5
ISO 8637-2Extracorporeal systems for blood purification - Part 2: Extracorporeal blood and fluid circuits for haemodialysers, haemodiafilters, haemofilters and haemoconcentrators
ISO 594/1 3; ISO 80369; ISO 8637-2; ISO 5356-1 Luer Tapered Plugs5; ISO 5356-1 Luer Ref Conical Fitting5
ISO 80369Name not checked yet
ISO 594/1 3; ISO 80369; ISO 8637-2; ISO 5356-1 Luer Tapered Plugs5; ISO 5356-1 Luer Ref Conical Fitting5
ISO 80369-2Small-bore connectors for liquids and gases in healthcare applications - Part 2: Connectors for respiratory applications
ISO 594/1 Fig 4; ISO 80369 ___________________________________________ 1; ISO 80369-2; ISO 80369-3; ISO 80369-6
ISO 80369-3Small-bore connectors for liquids and gases in healthcare applications - Part 3: Connectors for enteral applications
ISO 594/1 Fig 4; ISO 80369 ___________________________________________ 1; ISO 80369-2; ISO 80369-3; ISO 80369-6
ISO 80369-6Small bore connectors for liquids and gases in healthcare applications - Part 6: Connectors for neural applications
ISO 594/1 Fig 4; ISO 80369 ___________________________________________ 1; ISO 80369-2; ISO 80369-3; ISO 80369-6
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active3039.01
The scope document we hold says it was valid until 2026-03-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.
Accredited scope, certificate 3039.01
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | Dimensional Metrology | ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 | Electronic | to 12 in |
| 2 | Dimensional Metrology | - | Electronic | See scope document |
| 3 | Dimensional Metrology | - | Electronic | See scope document |
| 4 | Dimensional Metrology | ISO 594/1 3; ISO 80369; ISO 8637-2; ISO 5356-1 Luer Tapered Plugs5; ISO 5356-1 Luer Ref Conical Fitting5 | Steel | to 50 mm |
| 5 | Dimensional Metrology | ISO 594/1 Fig 4; ISO 80369 ___________________________________________ 1; ISO 80369-2; ISO 80369-3; ISO 80369-6 | Steel | to 50 mm |
| 6 | Dimensional Metrology | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- BHD Test & MeasurementThornton, CO · ~1,995 kmA2LAShares 3 accredited methods and materialsANSI/NCSL Z540-1-1994ElectronicSteel
- All American Scales & CalibrationParis, OH · ~99 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Steel
- Trescal, Inc - Milwaukee, WIMilwaukee, WI · ~561 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Steel
- Accu-ChekCorydon, IN · ~562 kmA2LAShares 2 accredited materialsElectronicSteel
- ACR Technical ServicesNewport News, VA · ~649 kmA2LAShares 2 accredited methods and materialsANSI/NCSL Z540-1-1994Steel
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.