Tektronix, Inc. - Covina
1411 North Grand Avenue, Suite 300, 91724, Covina, CA, United States
Visit website- Scope lines
- 32
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 32 scope lines.
A2LA certificate 2357.10 · 32 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540-3-2006 | - | to 48 in |
| 2 | Ohms Law Method | - | See scope document |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 3 of 31
Parameter/Equipment
Range CMC 2, 4 (±) Comments
DC Resistance – Generate
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(0.33 to 1.099 999) kΩ
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
(0.33 to 1.099 999) MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 M
Ω
19 MΩ
100 MΩ
38 µΩ/Ω + 0.78 mΩ
27 µΩ/Ω + 1.2 mΩ
23 µΩ/Ω + 1.1 mΩ
23 µΩ/Ω + 1.6 mΩ
22 µΩ/Ω + 1.6 mΩ
22 µΩ/Ω + 16 mΩ
22 µΩ/Ω + 16 mΩ
23 µΩ/Ω + 0.16 Ω
23 µΩ/Ω + 0.16 Ω
27 µΩ/Ω + 1.6 Ω
27 µΩ/Ω + 1.6 Ω
59 µΩ/Ω + 23 Ω
0.10 mΩ/Ω + 39 Ω
0.21 mΩ/Ω + 1.9 kΩ
0.40 mΩ/Ω + 2.3 kΩ
2.4 mΩ/Ω + 78 kΩ
12 mΩ/Ω + 0.39 MΩ
49 µΩ
0.12 mΩ
0.16 mΩ
0.21 mΩ
0.42 mΩ
0.97 mΩ
1.8 mΩ
6.4 mΩ
12 mΩ
64 mΩ
0.12 Ω
0.82 Ω
1.9 Ω
13 Ω
57 Ω
0.89 kΩ
1.7 kΩ
20 kΩ
Fluke 5522A
Fluke 5730A
DC Current – Measure
3
0 A
Up to 1 pA
(1 to 10) pA
(10 to 100) pA
(0.1 to 1) nA
(1 to 10) nA
(10 to 100) nA
(0.1 to 1) µA
0 to 200 µA
(0.2 to 2) mA
(2 to 20) mA
2.2 pA
13 fA/pA + 8.1 fA
6 fA/pA + 8.1 fA
2 fA/pA + 35 fA
0.6 pA/nA + 230 fA
0.6 pA/nA + 2.3 pA
0.6 pA/nA + 23 pA
0.6 nA/pA + 350 nA
13 µA/A + 0.40 nA
14 µA/A + 4.0 nA
14 µA/A + 40 nA
3458A, open
Keithley 6430
Fluke 8508A | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 4 of 31
Parameter/Equipment
Range CMC 2, 4 (±) Comments
DC Current – Measure3
(cont)
(20 to 200) mA
(0.2 to 2) A
(2 to 20) A
(20 to 50) A
(50 to 100) A
(100 to 300) A
(47 to 85.5) A
(85.5 to 90.9) A
(90.9 to 95) A
48 µA/A + 0.80 µA
0.18 mA/A + 16 µA
0.41 mA/A + 0.4 mA
0.40 mA/A + 0.39 A
0.40 mA/A + 0.78 A
0.41 mA/A + 0.23 A
0.12 mA/A
69 µA/A
65 µA/A
3458A w/ various
shunts
34465A w/ IT700-S
current transducer
DC Resistance –
Measure
3
True Ohms Mode
Normal Mode
High Voltage Mode
Up to 2 Ω
(2 to 20) Ω
(20 to 200) Ω
(0.2 to 2) kΩ
(2 to 20) kΩ
(2 to 200) kΩ
(0.2 to 2) MΩ
(2 to 20) MΩ
(20 to 200) MΩ
(0.2 to 2) GΩ
(2 to 20) GΩ
19 µΩ/Ω + 4 µΩ
10 µΩ/Ω + 14 µΩ
8.8 µΩ/Ω + 50 µΩ
8.7 µΩ/Ω + 0.5 mΩ
8.7 µΩ/Ω + 5 mΩ
8.9 µΩ/Ω + 50 mΩ
11 µΩ/Ω + 1 Ω
21 µΩ/Ω + 10 Ω
68 µΩ/Ω + 1 kΩ
0.19 mΩ/Ω + 0.1 MΩ
1.5 mΩ/Ω + 10 MΩ
Fluke 8508A
Parameter/Range
Frequency CMC 2, 4 (±) Comments
AC Voltage – Generate3
(0.2 to 2.2) mV
(2.2 to 22) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
0.41 mV/V + 3.9 µV
0.34 mV/V + 3.9 µV
0.35 mV/V + 3.9 µV
0.39 mV/V + 3.9 µV
0.63 mV/V + 4.7 µV
1.1 mV/V + 9.3 µV
1.5 mV/V + 19 µV
2.8 mV/V + 19 µV
0.24 mV/V + 3.9 µV
0.11 mV/V + 3.9 µV
0.10 mV/V + 3.9 µV
0.20 mV/V + 3.9 µV
0.47 mV/V + 4.7 µV
1.0 mV/V + 9.3 µV
1.3 mV/V + 19 µV
2.7 mV/V + 19 µV
Fluke 5730A
w/ Fluke 5725A | to 20 GΩ |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 5 of 31
Parameter/Range
Frequency CMC 2, 4 (±) Comments
AC Voltage – Generate3
(cont)
(22 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(220 to 1100) V
(220 to 750) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(40 Hz to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(15 to 50) Hz
50 Hz to 1 kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
0.36 mV/V + 12 µV
92 µV/V + 6.2 µV
58 µV/V + 6.2 µV
0.12 mV/V + 6.2 µV
0.31 mV/V + 16 µV
0.62 mV/V + 19 µV
1.3 mV/V + 23 µV
2.6 mV/V + 47 µV
0.49 mV/V + 39 µV
87 µV/V + 16 µV
39 µV/V + 7.8 µV
63 µV/V + 9.3 µV
0.11 mV/V + 31 µV
0.32 mV/V + 78 µV
0.94 mV/V + 0.19 mV
1.6 mV/V + 0.31 mV
0.37 mV/V + 0.39 mV
92 µV/V + 0.16 mV
39 µV/V + 54 µV
63 µV/V + 93 µV
79 µV/V + 0.19 mV
0.23 mV/V + 0.62 mV
0.93 mV/V + 1.9 mV
1.4 mV/V + 3.1 mV
0.43 mV/V + 3.9 mV
88 µV/V + 1.6 mV
53 µV/V + 0.54 mV
79 µV/V + 0.93 mV
0.14 mV/V + 2.3 mV
0.85 mV/V + 16 mV
4.2 mV/V + 39 mV
7.8 mV/V + 78 mV
0.28 mV/V + 16 mV
69 µV/V + 3.1 mV
78 µV/V + 3.1 mV
0.13 mV/V + 4.7 mV
0.47 mV/V + 8.5 mV
0.47 mV/V + 8.5 mV
1.8 mV/V + 35 mV
Fluke 5730A w/
Fluke 5725A | ||
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 6 of 31
Parameter/Range
Frequency CMC 2, 4 (±) Comments
AC Voltage – Generate3
(cont)
Wideband Output:
Up to 1.1 mV
(1.1 to 3) mV
(3 to 11) mV
(11 to 33) mV
(33 to 110) mV
(110 to 330) mV
(10 to 30) Hz
30 Hz to 120 kHz
(0.12 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
30 Hz to 120 kHz
(0.12 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
30 Hz to 120 kHz
(0.12 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
30 Hz to 120 kHz
(0.12 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
30 Hz to 120 kHz
(0.12 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
30 Hz to 120 kHz
(0.12 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
2.4 mV/V
0.98 mV/V
2.2 mV/V + 2.3 µV
3.7 mV/V + 2.3 µV
5.5 mV/V + 2.3 µV
13 mV/V + 12 µV
2.4 mV/V
0.94 mV/V
1.3 mV/V + 2.3 µV
2.2 mV/V + 2.3 µV
4.9 mV/V + 2.3 µV
13 mV/V + 2.3 µV
2.4 mV/V
0.94 mV/V
1.1 mV/V + 2.3 µV
2.0 mV/V + 2.3 µV
3.9 mV/V + 2.3 µV
8.6 mV/V + 2.3 µV
2.4 mV/V
0.91 mV/V
1.0 mV/V + 2.3 µV
2.0 mV/V + 2.3 µV
3.8 mV/V + 2.3 µV
8.5 mV/V + 2.3 µV
2.4 mV/V
0.87 mV/V
1.1 mV/V + 2.3 µV
2.0 mV/V + 2.3 µV
3.8 mV/V + 2.3 µV
8.1 mV/V + 2.3 µV
2.3 mV/V
0.84 mV/V
1.1 mV/V + 2.3 µV
2.0 mV/V + 2.3 µV
3.8 mV/V + 2.3 µV
8.5 mV/V + 2.3 µV
Fluke 5730A | to 1.1 mV |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 7 of 31
Parameter/Range
Frequency CMC 2, 4 (±) Comments
AC Voltage – Generate3
(cont)
Wideband Output:
330 mV to 1.1 V
(1.1 to 3.5) V
(1 to 85) kV
(10 to 30) Hz
30 Hz to 120 kHz
(0.12 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(10 to 30) Hz
30 Hz to 120 kHz
(0.12 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
60 Hz
2.3 mV/V
0.84 mV/V
1.0 mV/V + 2.3 µV
2.0 mV/V + 2.3 µV
3.8 mV/V + 2.3 µV
8.5 mV/V + 2.3 µV
2.3 mV/V
0.84 mV/V
1.0 mV/V + 2.3 µV
2.0 mV/V + 2.3 µV
3.8 mV/V + 2.3 µV
8.5 mV/V + 2.3 µV
5.9 mV/V
Fluke 5720A
Ross 120 kV
divider w/
34401A
AC Current – Generate3
(1 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.24 mA/A + 16 nA
0.16 mA/A + 9.3 nA
0.10 mA/A + 7.8 nA
0.27 mA/A + 12 nA
1.0 mA/A + 62 nA
0.24 mA/A + 39 nA
0.16 mA/A + 31 nA
0.10 mA/A + 31 nA
0.20 mA/A + 0.10 µA
1.0 mA/A + 0.62 µA
0.24 mA/A + 0.39 µA
0.16 mA/A + 0.31 µA
0.10 mA/A + 0.31 µA
0.19 mA/A + 0.54 µA
1.0 mA/A + 4.7 µA
0.24 mA/A + 3.9 µA
0.16 mA/A + 3.1 µA
0.10 mA/A + 2.3 µA
0.19 mA/A + 3.1 µA
1.0 mA/A + 9.3 µA
Fluke 5730A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 8 of 31
Parameter/Range
Frequency CMC 2, 4, 6 (±) Comments
AC Current – Generate3
(cont)
(0.22 to 2.2) A
(2.2 to 11) A
Up to 329.99 µA
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(11 to 20.5) A
Clamp-On Only:
(10 to 149.999) A
(150 to 1025) A
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 30) kHz
(10 to 30) kHz
(10 to 30) kHz
(10 to 45) Hz
(10 to 45) Hz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.24 mA/A + 31 µA
0.40 mA/A + 78 µA
6.2 mA/A + 0.16 mA
0.40 mA/A + 0.13 mA
0.76 mA/A + 0.29 mA
2.8 mA/A + 0.58 mA
12 mA/A + 0.31 μA
7.8 mA/A + 0.47 μA
3.3 mA/A + 3.1 μA
3.1 mA/A + 0.16 mA
1.4 mA/A + 78 μA
1.4 mA/A + 78 μA
0.95 mA/A + 3.9 mA
1.2 mA/A + 3.9 mA
23 mA/A + 3.9 mA
0.31 %
0.81 %
0.33 %
0.82 %
Fluke 5730A
Fluke 5730A
w/ 5725A
Fluke 5522A
Fluke 5522A w/coil
AC Voltage – Measure
Up to 199.99 mV
(0.2 to 1.9999) V
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
0.35 mV/V + 14 µV
0.16 mV/V + 4.0 µV
0.12 mV/V + 4.0 µV
0.12 mV/V + 2.0 µV
0.14 mV/V + 4.0 µV
0.35 mV/V + 8.0 µV
0.77 mV/V + 20 µV
0.50 mV/V + 0.12 mV
0.12 mV/V + 20 µV
0.11 mV/V + 20 µV
79 µV/V + 20 µV
0.11 mV/V + 20 µV
0.23 mV/V + 40 µV
0.59 mV/V + 0.20 mV
3.0 mV/V + 2.0 mV
10 mV/V + 20 mV
Fluke 8508A | ||
| 9 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 9 of 31
Parameter/Range
Frequency CMC 2, 4 (±) Comments
AC Voltage – Measure
(cont)
(2 to 19.999) V
(20 to 199.99) V
(100 to 1050) V
(1 to 85) kV
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 100) Hz
(0.1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 10) Hz
(10 to 40) Hz
(40 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
60 Hz
0.36 mV/V + 1.2 mV
0.13 mV/V + 0.20 mV
95 µV/V + 0.20 mV
85 µV/V + 0.20 mV
0.11 mV/V + 0.20 mV
0.22 mV/V + 0.40 mV
0.58 mV/V + 2.0 mV
3.0 mV/V + 20 mV
10 mV/V + 0.20 V
0.43 mV/V + 12 mV
0.13 mV/V + 2.0 mV
98 µV/V + 2.0 mV
83 µV/V + 2.0 mV
0.12 mV/V + 2.0 mV
0.22 mV/V + 4.0 mV
0.58 mV/V + 20 mV
1.6 mV/V + 0.2 V
5.2 mV/V + 2.0 V
0.50 mV/V + 10 mV
0.13 mV/V + 20 mV
0.16 mV/V + 20 mV
0.38 mV/V + 40 mV
0.66 mV/V + 0.20 V
5.9 mV/V
Fluke 8508A
Ross 120 kV divider
w/ 34401A
AC Current – Measure3
Up to 199.99 µA
(0.2 to 1.9999) mA
(2 to 19.999) mA
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
0.58 mA/A + 20 nA
0.52 mA/A + 20 nA
0.65 mA/A + 20 nA
3.1 mA/A + 20 nA
0.42 mA/A + 0.20 µA
0.31 mA/A + 0.20 µA
0.63 mA/A + 0.20 µA
3.1 mA/A + 0.20 µA
0.41 mA/A + 2.0 µA
0.31 mA/A + 2.0 µA
0.63 mA/A + 2.0 µA
3.7 mA/A + 2.0 µA
Fluke 8508A | 2 to 19.999 V |
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 10 of 31
Parameter/Range
Frequency CMC 2, 4, 6 (±) Comments
AC Current – Measure3
(cont)
(20 to 199.99) mA
(0.2 to 1.9999) A
(20 to 19.999) A
With Shunts:
(20 to 100) A
(100 to 300) A
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
(1 to 10) Hz
10 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
60 Hz
60 Hz
0.42 mA/A + 20 µA
0.30 mA/A + 20 µA
0.68 mA/A + 20 µA
0.57 mA/A + 0.20 mA
0.85 mA/A + 0.20 mA
2.4 mA/A + 0.20 mA
0.74 mA/A + 0.20 mA
2.1 mA/A + 0.20 mA
040 µA/A + 390 mA
0.41 mA/A + 230 mA
Fluke 8508A
3458A w/ various
shunts
Capacitance – Generate
3
(0.19 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
DC to 50 Hz
DC to 20 Hz
DC to 6 Hz
DC to 2 Hz
DC to 0.6 Hz
DC to 0.2 Hz
4.0 mF/F + 7.8 pF
4.0 mF/F + 7.8 pF
2.1 mF/F + 7.8 pF
2.1 mF/F + 78 pF
2.0 mF/F + 0.23 nF
2.1 mF/F + 0.78 nF
2.1 mF/F + 2.3 nF
2.1 mF/F + 7.8 nF
3.2 mF/F + 23 nF
3.6 mF/F + 78 nF
3.5 mF/F + 0.23 µF
3.5 mF/F + 0.78 µF
3.5 mF/F + 2.3 µF
3.5 mF/F + 7.8 µF
5.8 mF/F + 23 µF
8.5 mF/F + 78 µF
Fluke 5522A
AC Level Flatness3 –
(0.5, 1, 3) Vrms Thermal
Converter
10 Hz to < 30 kHz
(30 to < 100) kHz
(0.1 to < 1) MHz
(1 to < 3) MHz
(3 to < 8) MHz
(8 to < 20) MHz
(20 to < 30) MHz
(30 to < 50) MHz
(50 to < 70) MHz
(70 to < 80) MHz
(80 to < 100) MHz
100 MHz
0.12 %
0.23 %
0.29 %
0.58 %
0.70 %
0.71 %
0.76 %
1.8 %
2.8 %
3.6 %
3.9 %
4.8 %
By comparison to
thermal voltage
converters w/
HP 3458A OPT 002 | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 11 of 31
Parameter/Equipment
Range CMC 2, 4, 6 (±) Comments
Oscilloscopes –
Amplitude DC Signal:
50 Ω Load
1 MΩ Load
Amplitude Square Wave:
10 Hz to 10 kHz:
50 Ω Load
1 MΩ Load
Bandwidth / Level Sine
Flatness
3
Time Marker
Rise Time – Generate
Resistance
0 V to ± 6.6 V
0 V to ± 130 V
1 mV to ± 6.0 V
p-p
10 Hz to 10 kHz
1 mV to ± 200 Vp-p
10 Hz to 10 kHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
(1.1 to 18) GHz
(18 to 26.5) GHz
(26.5 to 50) GHz
1 ns to 20 ms
50 ms to 5 s
Non-cardinal point
1 kHz to 2 MHz,
(200 to 300) ps
(2 to 10) MHz,
(200 to 350) ps
(40 to 60) Ω
(0.6 to 1.5) MΩ
1.9 mV/V + 31 µV
0.39 mV/V + 31 µV
2.1 mV/V + 31 µV
0.78 mV/V + 31 µV
2.9 %
3.1 %
4.1 %
4.7 %
4.0 %
4.1 %
7.2 %
2.5 μs/s
(19 + 38t) μs/s
39 μs/s
19 ps
19 ps
0.79 mΩ/Ω
0.79 mΩ/Ω
Fluke 5522A
Power meter & sensor
with signal generator
Fluke 5522A
t = time in seconds
Electrical Calibration of
Thermocouple Indicators3 –
Type B
Type C
(600 to 800) °C
(800 to 1550) °C
(1550 to 1820) °C
(0 to 1000) °C
(1000 to 1800) °C
(1800 to 2000) °C
(2000 to 2316) °C
0.29 °C
0.24 °C
0.20 °C
0.16 °C
0.21 °C
0.22 °C
0.29 °C
Fluke 7526A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 12 of 31
Parameter/Equipment
Range CMC 2 (±) Comments
Electrical Calibration of
Thermocouple Indicators3 –
(cont)
Type E
Type J
Type K
Type L
Type N
Type R
Type S
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 600) °C
(600 to 1000) °C
(-210 to -100) °C
(-100 to 800) °C
(800 to 1200) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 500) °C
(500 to 800) °C
(800 to 1372) °C
(-200 to -100) °C
(-100 to 900) °C
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 100) °C
(100 to 800) °C
(800 to 1300) °C
(-50 to -25) °C
(-25 to 0) °C
(0 to 100) °C
(100 to 400) °C
(400 to 600) °C
(600 to 1000) °C
(1000 to 1600) °C
(1600 to 1767) °C
(-50 to -25) °C
(-25 to 0) °C
(0 to 100) °C
(100 to 400) °C
(400 to 600) °C
(600 to 1000) °C
(1000 to 1600) °C
(1600 to 1767) °C
0.22 °C
0.14 °C
0.12 °C
0.12 °C
0.13 °C
0.20 °C
0.13 °C
0.13 °C
0.37 °C
0.16 °C
0.13 °C
0.13 °C
0.14 °C
0.13 °C
0.12 °C
0.57 °C
0.21 °C
0.14 °C
0.13 °C
0.13 °C
0.14 °C
0.44 °C
0.37 °C
0.32 °C
0.24 °C
0.20 °C
0.19 °C
0.18 °C
0.21 °C
0.41 °C
0.37 °C
0.31 °C
0.25 °C
0.21 °C
0.20 °C
0.20 °C
0.23 °C
Fluke 7526A | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 13 of 31
Parameter/Equipment
Range CMC 2 (±) Comments
Electrical Calibration of
Thermocouple Indicators3 –
(cont)
Type T
Type U
(-250 to -200) °C
(-200 to -100) °C
(-100 to 0) °C
(0 to 200) °C
(200 to 400) °C
(-200 to 0) °C
(0 to 200) °C
(200 to 600) °C
0.30 °C
0.16 °C
0.13 °C
0.12 °C
0.12 °C
0.17 °C
0.13 °C
0.13 °C
Fluke 7526A
Electrical Calibration of
RTDs3 –
PT 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
(-200 to -800) °C
(-200 to 630) °C
(-200 to 630) °C (JIS)
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.044 °C
0.044 °C
0.044 °C
0.041 °C
0.043 °C
0.044 °C
0.051 °C
0.098 °C
0.11 °C
0.11 °C
0.13 °C
0.036 °C
0.043 °C
0.044 °C
0.051 °C
0.066 °C
0.066 °C
0.073 °C
0.088 °C
0.029 °C
0.029 °C
0.036 °C
0.042 °C
0.050 °C
0.18 °C
0.057 °C
0.18 °C
Fluke 7526A
Fluke 5520A | ||
| 14 | propagation of uncertainty method | - | - |
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 15 of 31
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
AC Power – Generate
3
PF = (0 to 1) (cont)
(45 to 65) Hz
1.09 mW to 9.2 W
2.97 mW to 33.6 W
10.9 mW to 91.8 W
29.7 mW to 336.6 W
108.9 mW to 918 W
297 mW to 2244 W
72.6 mW to 4590 W
(1.49 W to 20 910) W
65 Hz to 1 kHz
(0.109 to 3.0) mW
(0.297 to 10.89) mW
(1.09 to 29.7) mW
(3.0 to 108.9) mW
65 Hz to 1 kHz
(10.9 to 297) mW
(29.7 to 726) mW
72.6 mW to 1.5 W
148.5 mW to 6.8 W
1.089 mW to 9.179 W
2.97 mW to 33.659 W
10.89 mW to 91.7898 W
(0.0297 to 336.5898) W
(0.1089 to 917.898) W
(0.297 to 2243.898) W
(0.726 to 4589.898) W
1.485 W to 20.91 kW
(1 to 5) kHz
(0.1089 to 2.9696) mW
(0.297 to 10.8893) mW
(1.089 to 29.6958) mW
(2.97 to 108.8934) mW
(10.89 to 296.958) mW
(29.7 to 725.945) mW
(72.6 to 1484.922) mW
148.5 mW to 6.7648 W
330 mV to 1020 V
(3.3 to 8.999) mA
(9 to 32.999) mA
(33 to 89.99) mA
(90 to 329.99) mA
(330 to 899.9) mA
(0.9 to 2.1999) A
(2.2 to 4.4999) A
(4.5 to 20.5) A
(33 to 329.99) mV
(3.3 to 8.999) mA
(9 to 32.999) mA
(33 to 89.99) mA
(90 to 329.99) mA
(33 to 329.99) mV
(330 to 899.9) mA
(0.9 to 2.1999) A
(2.2 to 4.4999) A
(4.5 to 20.5) A
330 mV to 1020 V
(3.3 to 8.999) mA
(9 to 32.999) mA
(33 to 89.99) mA
(90 to 329.99) mA
(330 to 899.9) mA
(0.9 to 2.1999) A
(2.2 to 4.4999) A
(4.5 to 20.5) A
(33 to 329.99) mV
(3.3 to 8.999) mA
(9 to 32.999) mA
(33 to 89.99) mA
(90 to 329.99) mA
(330 to 899.9) mA
(0.9 to 2.1999) A
(2.2 to 4.4999) A
(4.5 to 20.5) A
0.34 %
0.062 %
0.094 %
0.062 %
0.086 %
0.071 %
0.094 %
0.077 %
0.040 %
0.040 %
0.042 %
0.039 %
0.54 %
0.053 %
0.094 %
0.14 %
0.043 %
0.043 %
0.045 %
0.042 %
0.54 %
0.055 %
0.095 %
0.14 %
0.10 %
0.10 %
0.12 %
0.12 %
0.54 %
0.50 %
0.12 %
0.16 %
Fluke 5522A | ||
| 16 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 16 of 31
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
AC Power – Generate
3
PF = (0 to 1) (cont)
(1 to 5) kHz
1.089 mW to 9.179 W
2.97 mW to 33.659 W
10.89 mW to 91.7898 W
(0.0297 to 336.5898) W
(0.1089 to 917.898) W
(0.297 to 2243.898) W
(0.726 to 4589.898) W
1.485 W to 20.91 kW
(5 to 10) kHz
(0.1089 to 2.9696) mW
(0.297 to 10.8893) mW
(1.089 to 29.6958) mW
(2.97 to 108.8934) mW
(10.89 to 296.958) mW
(29.7 to 725.945) mW
(72.6 to 989.9667) mW
(5 to 10) kHz
1.089 mW to 9.179 W
2.97 mW to 33.659 W
10.89 mW to 91.7898 W
29.7 mW to 336.5898 W
(0.1089 to 917.898) W
(0.297 to 2243.898) W
(0.726 to 3059.9898) W
(10 to 30) kHz
(0.1089 to 2.9696) mW
(0.297 to 10.8893) mW
(1.089 to 29.6958) mW
(2.97 to 108.8934) mW
1.089 mW to 9.179 W
2.97 mW to 33.659 W
10.89 mW to 91.7898 W
29.7 mW to 336.5898 W
330 mV to 1020 V
(3.3 to 8.999) mA
(9 to 32.999) mA
(33 to 89.99) mA
(90 to 329.99) mA
(330 to 899.9) mA
(0.9 to 2.1999) A
(2.2 to 4.4999) A
(4.5 to 20.5) A
(33 to 329.99) mV
(3.3 to 8.999) mA
(9 to 32.999) mA
(33 to 89.99) mA
(90 to 329.99) mA
(330 to 899.9) mA
(0.9 to 2.1999) A
(2.2 to 2.999 99) A
330 mV to 1020 V
(3.3 to 8.999) mA
(9 to 32.999) mA
(33 to 89.99) mA
(90 to 329.99) mA
(330 to 899.9) mA
(0.9 to 2.1999) A
(2.2 to 2.999 99) A
(33 to 329.99) mV
(3.3 to 8.999) mA
(9 to 32.999) mA
(33 to 89.99) mA
(90 to 329.99) mA
330 mV to 1020 V
(3.3 to 8.999) mA
(9 to 32.999) mA
(33 to 89.99) mA
(90 to 329.99) mA
0.10 %
0.10 %
0.12 %
0.12 %
0.54 %
0.50 %
0.12 %
0.16 %
0.34 %
0.34 %
0.35 %
0.34 %
0.61 %
0.57 %
0.57 %
0.33 %
0.34 %
0.34 %
0.36 %
0.35 %
0.61 %
0.57 %
1.2 %
1.2 %
1.2 %
1.2 %
1.2 %
1.2 %
1.3 %
1.3 %
Fluke 5522A
Power Supplies – Measure
3
Ripple / Noise RMS - CV
Ripple / Noise RMS - CC
Transient Response
Time
Voltage
Up to 1000 V
Up to 50 A
Up to 5 ms
Up to 1 V
59 µV/V
59 µA/A
2 ms/s
8.3 mV/V
Tektronix MDO3014 with
load
Tektronix MDO3014 with
load | to 1020 V |
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 17 of 31
III. Electrical – RF / Microwave
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
RF Power – Measure
3
1 mW Power Meter
Reference
50 MHz
0.26 %
HP 478A-H76 w/ HP 432A
& DMM
Thermistor Mount
Calibration – Calibration
Factor
3
50 MHz reference
(9 to 50) kHz
(50 to 100) kHz
(0.1 to 2000) MHz
(2.0 to 4.2) GHz
(4.2 to 10.0) GHz
(10.0 to 11.0) GHz
(11.0 to 18.0) GHz
0.85 %
0.68 %
0.92 %
0.86 %
0.88 %
0.92 %
0.96 %
1.0 %
Tegam 2505A/1830A,
Agilent EPM 441A
Power Sensor Calibration –
Calibration Factor
3
(10 to 50) MHz
(50 to 80) MHz
(0.08 to 2.7) GHz
(2.7 to 4.6) GHz
(4.6 to 5.6) GHz
(5.6 to 9.2) GHz
(9.2 to 11.4) GHz
(11.4 to 12.4) GHz
(12.4 to 13.25) GHz
(13.25 to 19) GHz
(19 to 22) GHz
(22 to 29) GHz
(29 to 34) GHz
(34 to 39) GHz
(39 to 43) GHz
(43 to 49) GHz
49 GHz
50 GHz
1.5 %
1.0 %
1.1 %
1.2 %
1.3 %
1.4 %
1.5 %
1.6 %
1.7 %
1.8 %
1.9 %
2.4 %
2.7 %
3.0 %
3.5 %
3.9 %
4.4 %
4.7 %
Tegam 2505A/1830A,
Agilent EPM 441A
Reflection Coefficient
3
(Into 50 Ω) –
0 < ρ ≤ 0.2
0.2 < ρ ≤ 0.4
0.4 < ρ ≤ 0.6
30 kHz to 1.2 GHz
(1.2 to 3) GHz
(3 to 6) GHz
30 kHz to 1.2 GHz
(1.2 to 3) GHz
(3 to 6) GHz
30 kHz to 1.2 GHz
(1.2 to 3) GHz
(3 to 6) GHz
0.0019 ρ
0.0028 ρ
0.0053 ρ
0.0022 ρ
0.0031 ρ
0.0056 ρ
0.0027 ρ
0.0035 ρ
0.0062 ρ
Agilent 8753D/
Agilent 85032B | ||
| 18 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 18 of 31
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Reflection Coefficient
3
(Into 50 Ω) – (cont)
0.6 < ρ ≤ 0.8
0.8 < ρ ≤ 1
0.000 < ρ ≤ 0.0476
0.0476 < ρ ≤ 0.1111
0.1111 < ρ ≤ 0.200
0.200 < ρ ≤ 0.3333
0.3333 < ρ ≤ 0.500
30 kHz to 1.2 GHz
(1.2 to 3) GHz
(3 to 6) GHz
30 kHz to 1.2 GHz
(1.2 to 3) GHz
(3 to 6) GHz
40 MHz to 2 GHz
(> 2 to 20) GHz
(> 20 to 40) GHz
(> 40 to 50) GHz
40 MHz to 2 GHz
(> 2 to 20) GHz
(> 20 to 40) GHz
(> 40 to 50) GHz
40 MHz to 2 GHz
(> 2 to 20) GHz
(> 20 to 40) GHz
(> 40 to 50) GHz
40 MHz to 2 GHz
(> 2 to 20) GHz
(> 20 to 40) GHz
(> 40 to 50) GHz
40 MHz to 2 GHz
(> 2 to 20) GHz
(> 20 to 40) GHz
(> 40 to 50) GHz
0.0033 ρ
0.0042 ρ
0.0078 ρ
0.004 ρ
0.005 ρ
0.0091 ρ
0.0094 ρ
0.0095 ρ
0.018 ρ
0.021 ρ
0.013 ρ
0.013 ρ
0.021 ρ
0.026 ρ
0.014 ρ
0.014 ρ
0.024 ρ
0.031 ρ
0.016 ρ
0.017 ρ
0.028 ρ
0.038 ρ
0.019 ρ
0.02 ρ
0.034 ρ
0.049 ρ
Agilent 8753D/
Agilent 85032B
Anritsu 37397C/
HP 85056A
Anritsu 37397C /
HP 85054B/85052B/85056A
RF Power – Generate &
Measure
3
(-30 to +30) dBm
(-70 to -30) dBm
(-35 to + 20) dBm
3 Hz to 100 kHz
(0.1 to 100) MHz
100 MHz to 2.4 GHz
(2.4 to 8.0) GHz
(8.0 to 12.4) GHz
(12.4 to 18.0) GHz
(18.0 to 26.5) GHz
(26.5 to 33.0) GHz
(33.0 to 40.0) GHz
(40.0 to 44.0) GHz
(44.0 to 50.0) GHz
0.060 dB
0.091 dB
0.027 dBm
0.042 dBm
0.064 dBm
0.082 dBm
0.11 dBm
0.098 dBm
0.11 dBm
0.11 dBm
0.14 dBm
0.14 dBm
HP 33250A / 3458A
Signal generator & power
meter w/ power sensor:
NRP50T w/ power
meter | to 1 |
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 19 of 31
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
RF Power – Generate3
(-56 to 27) dBm
(20 to 24) dBm
(14 to 20) dBm
(-17 to 14) dBm
(-48 to -17) dBm
(-74 to -48) dBm
(-84 to -74) dBm
(-94 to -84) dBm
(-130 to -94) dBm
DC to 5 MHz
(> 5 to 20) MHz
Up to 100 kHz
(0.1 to 128) MHz
Up to 100 kHz
(0.1 to 128) MHz
(128 to 300) MHz
(0.3 to 1.4) GHz
Up to 100 kHz
(0.1 to 128) MHz
(128 to 300) MHz
(0.3 to 1.4) GHz
(1.4 to 4.0) GHz
Up to 100 kHz
(0.1 to 128) MHz
(128 to 300) MHz
(0.3 to 1.4) GHz
(1.4 to 3) GHz
(3 to 4) GHz
(0.1 to 10) MHz
(10 to 300) MHz
(0.3 to 1.4) GHz
(1.4 to 4) GHz
(0.1 to 10) MHz
(10 to 128) MHz
(128 to 300) MHz
(0.3 to 1.4) GHz
(1.4 to 4) GHz
(0.1 to 10) MHz
(10 to 128) MHz
(128 to 300) MHz
(0.3 to 3) GHz
(10 to 128) MHz
128 MHz to 1.4 GHz
0.19 dB
0.35 dB
0.024 dB
0.048 dB
0.024 dB
0.046 dB
0.064 dB
0.16 dB
0.024 dB
0.051 dB
0.064 dB
0.16 dB
0.25 dB
0.024 dB
0.051 dB
0.064 dB
0.17 dB
0.25 dB
0.41 dB
0.16 dB
0.086 dB
0.32 dB
0.41 dB
0.39 dB
0.089 dB
0.24 dB
0.40 dB
0.80 dB
0.40 dB
0.24 dB
0.39 dB
0.80 dB
0.58 dB
1.3 dB
Tektronix AFG2021
Fluke 96270A/LL/FF
w/leveling head
RF Power – Generate
(Microwave Output)
Up to 100 MHz
(0.1 to 1) GHz
(1 to 2.4) GHz
(2.4 to 8) GHz
(8 to 12) GHz
(12 to 18 GHz
(18 to 22 GHz
(22 to 26.5) GHz
0.43 %
0.57 %
0.70 %
0.88 %
1.0 %
1.2 %
1.6 %
2.5 %
Fluke 96270A/LL/FF
w/leveling head | ||
| 20 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 20 of 31
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
RF Attenuation – Tuned
RF Power Measure
3
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -95) dB
(-95 to -100) dB
(-100 to -105) dB
(-105 to -110) dB
(-110 to -115) dB
(-115 to -120) dB
(-120 to -125) dB
(0 to -5) dB
(-5 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -85) dB
(-85 to -90) dB
(-90 to -100) dB
(-100 to -105) dB
(-105 to -110) dB
(-110 to -115) dB
(-115 to -120) dB
(-120 to -130) dB
(-130 to -135) dB
100 kHz to 10 MHz
10 MHz to 22 GHz
0.018 dB
0.024 dB
0.029 dB
0.035 dB
0.041 dB
0.047 dB
0.052 dB
0.058 dB
0.064 dB
0.071 dB
0.075 dB
0.086 dB
0.094 dB
0.13 dB
0.21 dB
0.27 dB
0.018 dB
0.019 dB
0.024 dB
0.029 dB
0.035 dB
0.041 dB
0.047 dB
0.053 dB
0.059 dB
0.065 dB
0.068 dB
0.074 dB
0.082 dB
0.092 dB
0.094 dB
0.22 dB
0.47 dB
1.3 dB
Rohde & Schwarz
R&S FSMR3050 | 0 to -5 dB |
| 21 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 21 of 31
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
RF Attenuation – Tuned
RF Power Measure
3
(cont)
(0 to -5) dB
(-5 to -10) dB
(-10 to -15) dB
(-15 to -20) dB
(-20 to -25) dB
(-25 to -30) dB
(-30 to -35) dB
(-35 to -40) dB
(-40 to -45) dB
(-45 to -50) dB
(-50 to -55) dB
(-55 to -60) dB
(-60 to -65) dB
(-65 to -70) dB
(-70 to -75) dB
(-75 to -80) dB
(-80 to -85) dB
(-85 to -90) dB
(-90 to -95) dB
(-95 to -100) dB
(-100 to -105) dB
(-105 to -110) dB
(-110 to -115) dB
(-115 to -120) dB
(-120 to -130) dB
(-130 to -135) dB
(0 to -5) dB
(-5 to -20) dB
(-10 to -15) dB
(-15 to -20) dB
(-20 to -25) dB
(-25 to -30) dB
(-30 to -35) dB
(-35 to -40) dB
(-40 to -45) dB
(-45 to -50) dB
(-50 to -55) dB
(-55 to -60) dB
(-60 to -65) dB
(-65 to -70) dB
(-70 to -75) dB
(-75 to -80) dB
(-80 to -85) dB
(-85 to -90) dB
(22 to 26.5) GHz
(26.5 to 40) GHz
0.22 dB
0.28 dB
0.35 dB
0.34 dB
0.30 dB
0.21 dB
0.31 dB
0.26 dB
0.35 dB
0.41 dB
0.35 dB
0.32 dB
0.51 dB
0.38 dB
0.23 dB
0.27 dB
0.34 dB
0.31 dB
0.30 dB
0.27 dB
0.27 dB
0.31 dB
0.45 dB
0.31 dB
2.9 dB
1.3 dB
0.26 dB
0.25 dB
0.25 dB
0.25 dB
0.39 dB
0.29 dB
0.22 dB
0.44 dB
0.31 dB
0.45 dB
0.61 dB
0.41 dB
0.51 dB
0.41 dB
0.29 dB
0.41 dB
0.42 dB
0.41 dB
Rohde & Schwarz
R&S FSMR3050 | 0 to -5 dB |
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 22 of 31
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
RF Attenuation – Tuned
RF Power Measure
3
(cont)
(-90 to -95) dB
(-95 to -100) dB
(-100 to -105) dB
(-105 to -110) dB
(-110 to -115) dB
(-115 to -120) dB
(-120 to -125) dB
(0 to -5) dB
(-5 to -10) dB
(-10 to -15) dB
(-15 to -20) dB
(-20 to -25) dB
(-25 to -30) dB
(-30 to -35) dB
(-35 to -40) dB
(-40 to -45) dB
(-45 to -50) dB
(-50 to -55) dB
(-55 to -65) dB
(-60 to -65) dB
(-65 to -70) dB
(-70 to -75) dB
(-75 to -80) dB
(-80 to -85) dB
(-85 to -90) dB
(-90 to -95) dB
(-95 to -100) dB
(-100 to -105) dB
(-105 to -110) dB
(-110 to -115) dB
(26.5 to 40) GHz
(40 to 50) GHz
0.42 dB
0.40 dB
0.38 dB
0.47 dB
0.55 dB
0.18 dB
0.26 dB
0.36 dB
0.31 dB
0.45 dB
0.44 dB
0.50 dB
0.52 dB
0.51 dB
0.55 dB
0.43 dB
0.49 dB
0.30 dB
0.36 dB
0.36 dB
0.44 dB
0.35 dB
0.42 dB
0.36 dB
0.41 dB
0.37 dB
0.38 dB
0.39 dB
0.37 dB
0.35 dB
Rohde & Schwarz
R&S FSMR3050
Amplitude Modulation –
Generate/Measure
3
Rate: 10 Hz to 10 kHz
Depth: (5 to 99) %
Rate: 10 Hz to 50 kHz
Depth: (5 to 99) %
Rate: 50 kHz to 100 kHz
Depth: (5 to 99) %
Rate: 90 Hz to 150 Hz
Depth: (5 to 99) %
(0.1 to 10) MHz
(0.01 to 50) GHz
(0.01 to 50) GHz
(0.01 to 50) GHz
1.5 %
1.0 %
1.5 %
0.42 %
HP 83650B
monitored by
Rohde & Schwarz
R&S FSMR3050 | ||
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 23 of 31
Parameter/Range
Frequency
CMC
2, 4, 6 (±)
Comments
Frequency Modulation –
Measure
3
Rate: 10 Hz to 10 kHz
Dev: ≤ 50 kHz peak
Rate: 10 Hz to 100 kHz
Dev: ≤ 500 kHz peak
Rate: (100 to 200) kHz
Dev: ≤ 500 kHz peak
(0.1 to 10) MHz
(0.01 to 50) GHz
(0.01 to 50) GHz
1.2 %
1.2 %
3.5 %
R&S FSMR3050
Phase Modulation – Measure3
Rate: 10 Hz to 10 kHz
Rate: 10 Hz to 5 MHz
200 kHz to 10 MHz
10 MHz to 50 GHz
1.0 %
1.0 %
R&S FSMR3050
Phase Noise – Measure
3
Carrier Frequency:
(1 to 10) MHz
(-40 to -176) dBc
1 Hz Offset
10 Hz Offset
100 Hz Offset
1 kHz Offset
10 kHz Offset
100 kHz Offset
1 MHz Offset
2.7 dB
2.5 dB
1.6 dB
1.6 dB
1.6 dB
1.6 dB
4.0 dB
R&S FSMR3050
Phase Noise – Measure3
(10 to 100) MHz
(-66 to -175) dBc
1 Hz Offset
10 Hz Offset
100 Hz Offset
1 kHz Offset
10 kHz Offset
100 kHz Offset
1 MHz Offset
10 MHz Offset
> 30 MHz Offset
3.7 dB
2.8 dB
1.6 dB
1.6 dB
1.6 dB
1.6 dB
2.7 dB
3.3 dB
4.0 dB
R&S FSMR3050 | ||
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 24 of 31
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Phase Noise – Measure3
(cont)
100 MHz to 1 GHz
(-46 to -173) dBc
(1 to 3) GHz
(+10 to -170) dBc
(3 to 7) GHz
(+17 to -166) dBc
(7 to 10) GHz
(+20 to -175) dBc
(10 to 16) GHz
(+24 to -171) dBc
1 Hz Offset
10 Hz Offset
100 Hz Offset
1 kHz Offset
10 kHz Offset
100 kHz Offset
1 MHz Offset
10 MHz Offset
> 30 MHz Offset
1 Hz Offset
10 Hz Offset
100 Hz Offset
1 kHz Offset
10 kHz Offset
100 kHz Offset
1 MHz Offset
10 MHz Offset
> 30 MHz Offset
1 Hz Offset
10 Hz Offset
100 Hz Offset
1 kHz Offset
10 kHz Offset
100 kHz Offset
1 MHz Offset
10 MHz Offset
> 30 MHz Offset
1 Hz Offset
10 Hz Offset
100 Hz Offset
1 kHz Offset
10 kHz Offset
100 kHz Offset
1 MHz Offset
10 MHz Offset
> 30 MHz Offset
1 Hz Offset
10 Hz Offset
100 Hz Offset
1 kHz Offset
10 kHz Offset
100 kHz Offset
1 MHz Offset
10 MHz Offset
> 30 MHz Offset
3.2 dB
2.4 dB
1.7 dB
1.6 dB
1.6 dB
1.6 dB
3.9 dB
4.0 dB
4.0 dB
4.2 dB
2.0 dB
1.6 dB
1.6 dB
1.6 dB
1.6 dB
3.8 dB
4.4 dB
4.1 dB
4.4 dB
2.6 dB
1.7 dB
1.6 dB
1.6 dB
1.6 dB
3.3 dB
3.9 dB
4.6 dB
4.4 dB
2.7 dB
1.8 dB
1.6 dB
1.6 dB
1.6 dB
3.5 dB
3.3 dB
4.6 dB
3.2 dB
2.7 dB
1.7 dB
1.6 dB
1.6 dB
1.6 dB
3.3 dB
4.1 dB
4.0 dB
R&S FSMR3050 | ||
| 25 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 25 of 31
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Phase Noise – Measure
3
(cont)
(16 to 26.5) GHz
(+28 to -167) dBc
(26.5 to 50) GHz
(+34 to -161) dBc
1 Hz Offset
10 Hz Offset
100 Hz Offset
1 kHz Offset
10 kHz Offset
100 kHz Offset
1 MHz Offset
10 MHz Offset
> 30 MHz Offset
1 Hz Offset
10 Hz Offset
100 Hz Offset
1 kHz Offset
10 kHz Offset
100 kHz Offset
1 MHz Offset
10 MHz Offset
> 30 MHz Offset
4.1 dB
2.7 dB
1.7 dB
1.6 dB
1.6 dB
1.6 dB
3.6 dB
4.2 dB
4.0 dB
4.1 dB
2.0 dB
1.8 dB
1.6 dB
1.6 dB
1.6 dB
3.7 dB
3.6 dB
4.4 dB
R&S FSMR3050
Average Noise &
Residuals (DANL)
3
(-30 to -170) dBm
20 Hz to 50 GHz
0.78 dB
50 Ω load
3rd Order
Intermodulation
3
(0 to -120) dB
(0 to -120) dB
200 Hz to 50 MHz
50 MHz to 50 GHz
2.1 dB
3.0 dB
Fluke 96270A,
Agilent 83650B
2nd Harmonic
Distortion3
(0 to -120) dB
(0 to -120) dB
200 Hz to 50 MHz
50 MHz to 50 GHz
2.8 dB
3.8 dB
Fluke 96270A,
Agilent 83650B | to 50 GHz |
| 26 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 26 of 31
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
Digital Modulation –
Measure
3
Carrier: 2 MHz to 50 GHz
Error Vector Magnitude
for Modulation
Phase Error for
Modulation
Symbol Rate
≤ 1 MHz
≤ 10 MHz
≤ 15 MHz
Mod Freq Span
≤ 100 kHz
≤ 1 MHz
≤ 10 MHz
> 10 MHz
0.53 %
1.1 %
2.1 %
0.32°
0.42°
0.64°
1.3°
Rohde & Schwarz
R&S FSMR3050
Types: 2FSK & 4FSK (include
GFSK), BPSK, QPSK (3GPP
WCDMA, CDMA2000®),
OQPSK, DQPSK, π/4 DQPSK,
8PSK, D8PSK, 3 π/8 8PSK
(EDGE), 16QAM, 32QAM,
64QAM, 128QAM, 256 QAM,
D16QAM, D32QAM,
D64QAM, D128QAM,
D256QAM, 8VSB,
GSM, NADC, PDC, PHS,
Bluetooth®, DECT, TETRA
Distortion– Measure
Fundamental
Frequency
3
20 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
Amplitude Modulation
Distortion
Depth of Modulation:
5 % to 99 %
Frequency Modulation
Distortion
Deviation < 10 kHz
Deviation < 50 kHz
Deviation < 100 kHz
Deviation < 500 kHz
Phase Modulation
Distortion
Distortion – Audio Input
(-100 to 0) dB
(-80 to 0) dB
(-70 to 0) dB
(-65 to 0) dB
Carrier Frequency:
100 kHz to 10 MHz
≥ 10 MHz to 4 GHz
200 kHz to 10 MHz
≥ 10 MHz to 4 GHz
200 kHz to 10 MHz
≥ 10 MHz to 4 GHz
100 Hz to 100 kHz
1.2 dB
2.3 dB
2.3 dB
0.36 %
0.44 %
0.19 %
0.38 %
0.20 %
0.38 %
0.18 %
0.18 %
0.60 dB
HP 8903B
R&S FSMR3050 | 2 to 50 MHz to GHz |
| 27 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 27 of 31
IV. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments
Scales & Balances
3
(5 to 10) mg
(10 to 20) mg
(20 to 50) mg
(50 to 100) mg
(100 to 200) mg
(0.2 to 0.5) g
(0.5 to 1) g
(1 to 2) g
(2 to 3) g
(3 to 5) g
(5 to 10) g
(10 to 50) g
(50 to 100) g
(100 to 200) g
(200 to 300) g
(300 to 500) g
(0.5 to 1) kg
(1 to 2) kg
(2 to 3) kg
(3 to 3.5) kg
(0.25 to 1) lb
((113.398 to 453.592) g)
(1 to 10) lb
((453.592 to 4535.92) g)
(10 to 25) lb
(4535.92 g to 11.3398 kg)
(25 to 50) lb
((11.3398 to 22.6796) kg)
(50 to 100) lb
((22.6796 to 45.3952) kg)
(100 to 250) lb
((45.3592 to 113.398) kg)
(250 to 500) lb
((113.398 to 226.796) kg)
16 µg
16 µg
16 µg
29 µg
29 µg
29 µg
65 µg
65 µg
130 µg
73 µg
87 µg
0.15 mg
0.3 mg
0.65 mg
0.98 mg
1.6 mg
2.9 mg
6.1 mg
9.1 mg
14 mg
44 mg
0.44 g
0.65 g
26 g
27 g
29 g
35 g
Class S1 weights
Class F weights
Mass
(1 to 20) mg
30 mg
(50 to 200) mg
300 mg
500 mg
1 g
2 g
3 g
5 g
10 g
20 g
30 g
50 g
100 g
14 µg
14 µg
14 µg
14 µg
14 µg
41 µg
41 µg
42 µg
41 µg
60 µg
87 µg
88 µg
0.14 mg
0.30 mg
Class S1 weights
using comparison
method | ||
| 28 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 28 of 31
Parameter/Equipment
Range
CMC2, 5, 6, 8 (±)
Comments
Mass (cont)
200 g
300 g
500 g
1 kg
2 kg
3 kg
5 kg
20 lb
(9.071 85 kg)
50 lb
(22.6796 kg)
0.60 mg
0.89 mg
1.4 mg
2.9 mg
5.9 mg
8.7 mg
15 mg
22 mg
60 mg
Class S1 weights using
comparison method
Tachometers
(60 to 100 000) RPM
0.0023 RPM + 0.6R
Fluke 5522A
Torque – Measuring
Equipment
3
(10 to 100) ozfꞏin
(5 to 50) ozfꞏin
(40 to 400) ozfꞏin
(100 to 1000) lbfꞏin
(25 to 250) lbfꞏft
(60 to 600) lbfꞏft
(200 to 2000) lbfꞏft
0.59 %
0.30 %
0.30 %
0.30 %
0.30 %
0.29 %
0.31 %
1001-O-DTT
CDI 5000 ST w/
2000-400-02
2000-12-02
2000-14-02
Torque Transducers
(2 to 200) ozfꞏin
(4 to 110) lbfꞏin
(9 to 275) lbfꞏft
(275 to 2000) lbfꞏft
(2000 to 4000) lbfꞏft
0.045 %
0.046 %
0.052 %
0.046 %
0.061 %
Torque arms & wheels
w/ NIST Class F
weights
Pressure – Measuring
Equipment
(0 to 1) inꞏH2O
(1 to 5) inꞏH2O
(5 to 10) inꞏH2O
(10 to 20) inꞏH2O
(20 to 30) inꞏH2O
(-14.5 to 0) PSIG
(0 to 15) PSIG
Up to 75 PSIG
(75 to 150) PSIG
(0 to 600) PSIG
(600 to 1200) PSIG
(0 to 1500) PSIG
(1500 to 3000) PSIG
0.000 24 inꞏH
2O
0.000 50 inꞏH2O
0.000 97 inꞏH2O
0.0020 inꞏH2O
0.0029 inꞏH2O
0.012 % of FS
0.012 % + 0.0014 PSI
0.012 % of FS
0.013 %
0.013 % of FS
0.013 %
0.013 % of FS
0.013 %
Ruska 7250 lp
Mensor CPC 6050 | ||
| 29 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 29 of 31
Parameter/Equipment
Range
CMC2, 6, 8 (±)
Comments
Pressure – Measuring
Equipment (cont)
(0 to 15) PSIA
(15 to 30) PSIA
(0 to 75) PSIA
(50 to 150) PSIA
(0 to 600) PSIA
(600 to 1200) PSIA
(0 to 1500) PSIA
(1500 to 3000) PSIA
(-29 to 0) inꞏHg
0.012 % of FS
0.012 %
0.012 % of FS
0.013 %
0.013 % of FS
0.013 %
0.013 % of FS
0.013 %
0.0019 inꞏHg
Mensor CPC 6050
Ruska 7250 xi
Pressure – Measuring
Equipment
(3000 to 10 000) PSI
0.018 % IV
Fluke P3214
Gas Flow – Measuring
Equipment
Up to 10 sccm
(10 to 25) sccm
(25 to 50) sccm
(50 to 75) sccm
(75 to 100) sccm
(100 to 250) sccm
(250 to 500) sccm
(500 to 750) sccm
(750 to 1000) sccm
Up to 5 slm
(5 to 10) slm
(10 to 20) slm
(20 to 30) slm
(30 to 40) slm
(40 to 50) slm
(50 to 100) slm
(100 to 150) slm
(150 to 200) slm
(200 to 300) slm
0.04 sccm
0.1 sccm
0.19 sccm
0.28 sccm
0.37 sccm
0.96 sccm
1.9 sccm
2.8 sccm
3.8 sccm
0.02 slm
0.03 slm
0.08 slm
0.11 slm
0.15 slm
0.19 slm
0.37 slm
0.56 slm
0.75 slm
1.1 slm
Fluke Molbloc/Molbox
mass flow system
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Temperature – Measure
-196 to 0 °C
0 to 200 °C
200 to 420 °C
420 to 660 °C
0.061 °C
0.061 °C
0.11 °C
0.12 °C
Fluke 1595A w/5699
SPRT using
comparison
method | ||
| 30 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 30 of 31
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Temperature – Measuring
Equipment
-196 °C
(-80 to -38) °C
(-38 to 0.0) °C
(0.0 to 50.0) °C
(50 to 150) °C
(150 to 300) °C
(300 to 660) °C
0.027 °C
0.017 °C
0.017 °C
0.017 °C
0.029 °C
0.070 °C
0.41 °C
Fluke 1595A w/ 5699
& various baths & dry
wells
Relative Humidity –
Measuring Equipment
(10 to 95) %
0.53 % RH
Thunder Scientific
2500
Relative Humidity –
Measure
3
(12 to 79) %
1.2 % RH
Rotronic HP 23A w/
HC 2-S probe
VI. Time & Frequency
Parameter/Equipment
Range
CMC
2, 8 (±)
Comments
Frequency – Measuring
Equipment
(0.001 to 1000) Hz
1000 Hz to 20 MHz
10 MHz to 50 GHz
0.17 nHz/Hz
0.18 nHz/Hz
0.17 nHz/Hz
GPS disciplined
oscillator, Tektronix
AFG2021
GPS disciplined
Frequency – Measure
DC to 1.0 kHz
(1.0 to 1000) kHz
(1.0 to 225) MHz
(0.225 to 12.4) GHz
(0.5 to 40.0) GHz
0.12 mHz
0.29 nHz/Hz
38 pHz/Hz
39 pHz/Hz
1.2 Hz/GHz
Datum 9390 & 53132A
Datum 9390 & 5352B
Rise Time – Measure
20 ps to 1 ns
21 ps
83487A (RT = 0.35/BW)
____________________________________________
1
This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 31 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 31 of 31
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches,
R is the resolution of the device under test.
6 All CMC’s listed in % are percent of reading of input unless otherwise stated.
7 This scope meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 32 | ISO/IEC 17025:20 17; ANSI/NCSLI Z540-1-1994; ANSI/NCSLI Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- K-Light Laboratories Corp.Irwindale, CA · ~5 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Mitutoyo America CorporationCity of Industry, CA · ~10 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. MICHELLI CO., LLC - SANTA FE SPRINGSSanta Fe Springs, CA · ~23 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- RSA Industries Inc dba American GagePlacentia, CA · ~24 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Element U.S. Space & DefenseFullerton, CA · ~24 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.