Registers refreshed 2026-11-08.See refresh dates
United States

Tektronix, Inc. - Covina

1411 North Grand Avenue, Suite 300, 91724, Covina, CA, United States

Visit website
A2LA 2357.10ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
32
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 32 scope lines.

A2LA certificate 2357.10 · 32 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540-3-2006-to 48 in
2Ohms Law Method-See scope document
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 3 of 31 Parameter/Equipment Range CMC 2, 4 (±) Comments DC Resistance – Generate (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 1.099 999) kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ (0.33 to 1.099 999) MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 M Ω 19 MΩ 100 MΩ 38 µΩ/Ω + 0.78 mΩ 27 µΩ/Ω + 1.2 mΩ 23 µΩ/Ω + 1.1 mΩ 23 µΩ/Ω + 1.6 mΩ 22 µΩ/Ω + 1.6 mΩ 22 µΩ/Ω + 16 mΩ 22 µΩ/Ω + 16 mΩ 23 µΩ/Ω + 0.16 Ω 23 µΩ/Ω + 0.16 Ω 27 µΩ/Ω + 1.6 Ω 27 µΩ/Ω + 1.6 Ω 59 µΩ/Ω + 23 Ω 0.10 mΩ/Ω + 39 Ω 0.21 mΩ/Ω + 1.9 kΩ 0.40 mΩ/Ω + 2.3 kΩ 2.4 mΩ/Ω + 78 kΩ 12 mΩ/Ω + 0.39 MΩ 49 µΩ 0.12 mΩ 0.16 mΩ 0.21 mΩ 0.42 mΩ 0.97 mΩ 1.8 mΩ 6.4 mΩ 12 mΩ 64 mΩ 0.12 Ω 0.82 Ω 1.9 Ω 13 Ω 57 Ω 0.89 kΩ 1.7 kΩ 20 kΩ Fluke 5522A Fluke 5730A DC Current – Measure 3 0 A Up to 1 pA (1 to 10) pA (10 to 100) pA (0.1 to 1) nA (1 to 10) nA (10 to 100) nA (0.1 to 1) µA 0 to 200 µA (0.2 to 2) mA (2 to 20) mA 2.2 pA 13 fA/pA + 8.1 fA 6 fA/pA + 8.1 fA 2 fA/pA + 35 fA 0.6 pA/nA + 230 fA 0.6 pA/nA + 2.3 pA 0.6 pA/nA + 23 pA 0.6 nA/pA + 350 nA 13 µA/A + 0.40 nA 14 µA/A + 4.0 nA 14 µA/A + 40 nA 3458A, open Keithley 6430 Fluke 8508A
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 4 of 31 Parameter/Equipment Range CMC 2, 4 (±) Comments DC Current – Measure3 (cont) (20 to 200) mA (0.2 to 2) A (2 to 20) A (20 to 50) A (50 to 100) A (100 to 300) A (47 to 85.5) A (85.5 to 90.9) A (90.9 to 95) A 48 µA/A + 0.80 µA 0.18 mA/A + 16 µA 0.41 mA/A + 0.4 mA 0.40 mA/A + 0.39 A 0.40 mA/A + 0.78 A 0.41 mA/A + 0.23 A 0.12 mA/A 69 µA/A 65 µA/A 3458A w/ various shunts 34465A w/ IT700-S current transducer DC Resistance – Measure 3 True Ohms Mode Normal Mode High Voltage Mode Up to 2 Ω (2 to 20) Ω (20 to 200) Ω (0.2 to 2) kΩ (2 to 20) kΩ (2 to 200) kΩ (0.2 to 2) MΩ (2 to 20) MΩ (20 to 200) MΩ (0.2 to 2) GΩ (2 to 20) GΩ 19 µΩ/Ω + 4 µΩ 10 µΩ/Ω + 14 µΩ 8.8 µΩ/Ω + 50 µΩ 8.7 µΩ/Ω + 0.5 mΩ 8.7 µΩ/Ω + 5 mΩ 8.9 µΩ/Ω + 50 mΩ 11 µΩ/Ω + 1 Ω 21 µΩ/Ω + 10 Ω 68 µΩ/Ω + 1 kΩ 0.19 mΩ/Ω + 0.1 MΩ 1.5 mΩ/Ω + 10 MΩ Fluke 8508A Parameter/Range Frequency CMC 2, 4 (±) Comments AC Voltage – Generate3 (0.2 to 2.2) mV (2.2 to 22) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 0.41 mV/V + 3.9 µV 0.34 mV/V + 3.9 µV 0.35 mV/V + 3.9 µV 0.39 mV/V + 3.9 µV 0.63 mV/V + 4.7 µV 1.1 mV/V + 9.3 µV 1.5 mV/V + 19 µV 2.8 mV/V + 19 µV 0.24 mV/V + 3.9 µV 0.11 mV/V + 3.9 µV 0.10 mV/V + 3.9 µV 0.20 mV/V + 3.9 µV 0.47 mV/V + 4.7 µV 1.0 mV/V + 9.3 µV 1.3 mV/V + 19 µV 2.7 mV/V + 19 µV Fluke 5730A w/ Fluke 5725A
to 20 GΩ
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 5 of 31 Parameter/Range Frequency CMC 2, 4 (±) Comments AC Voltage – Generate3 (cont) (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (22 to 220) V (220 to 1100) V (220 to 1100) V (220 to 750) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (40 Hz to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (15 to 50) Hz 50 Hz to 1 kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz 0.36 mV/V + 12 µV 92 µV/V + 6.2 µV 58 µV/V + 6.2 µV 0.12 mV/V + 6.2 µV 0.31 mV/V + 16 µV 0.62 mV/V + 19 µV 1.3 mV/V + 23 µV 2.6 mV/V + 47 µV 0.49 mV/V + 39 µV 87 µV/V + 16 µV 39 µV/V + 7.8 µV 63 µV/V + 9.3 µV 0.11 mV/V + 31 µV 0.32 mV/V + 78 µV 0.94 mV/V + 0.19 mV 1.6 mV/V + 0.31 mV 0.37 mV/V + 0.39 mV 92 µV/V + 0.16 mV 39 µV/V + 54 µV 63 µV/V + 93 µV 79 µV/V + 0.19 mV 0.23 mV/V + 0.62 mV 0.93 mV/V + 1.9 mV 1.4 mV/V + 3.1 mV 0.43 mV/V + 3.9 mV 88 µV/V + 1.6 mV 53 µV/V + 0.54 mV 79 µV/V + 0.93 mV 0.14 mV/V + 2.3 mV 0.85 mV/V + 16 mV 4.2 mV/V + 39 mV 7.8 mV/V + 78 mV 0.28 mV/V + 16 mV 69 µV/V + 3.1 mV 78 µV/V + 3.1 mV 0.13 mV/V + 4.7 mV 0.47 mV/V + 8.5 mV 0.47 mV/V + 8.5 mV 1.8 mV/V + 35 mV Fluke 5730A w/ Fluke 5725A
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 6 of 31 Parameter/Range Frequency CMC 2, 4 (±) Comments AC Voltage – Generate3 (cont) Wideband Output: Up to 1.1 mV (1.1 to 3) mV (3 to 11) mV (11 to 33) mV (33 to 110) mV (110 to 330) mV (10 to 30) Hz 30 Hz to 120 kHz (0.12 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz 30 Hz to 120 kHz (0.12 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz 30 Hz to 120 kHz (0.12 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz 30 Hz to 120 kHz (0.12 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz 30 Hz to 120 kHz (0.12 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz 30 Hz to 120 kHz (0.12 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz 2.4 mV/V 0.98 mV/V 2.2 mV/V + 2.3 µV 3.7 mV/V + 2.3 µV 5.5 mV/V + 2.3 µV 13 mV/V + 12 µV 2.4 mV/V 0.94 mV/V 1.3 mV/V + 2.3 µV 2.2 mV/V + 2.3 µV 4.9 mV/V + 2.3 µV 13 mV/V + 2.3 µV 2.4 mV/V 0.94 mV/V 1.1 mV/V + 2.3 µV 2.0 mV/V + 2.3 µV 3.9 mV/V + 2.3 µV 8.6 mV/V + 2.3 µV 2.4 mV/V 0.91 mV/V 1.0 mV/V + 2.3 µV 2.0 mV/V + 2.3 µV 3.8 mV/V + 2.3 µV 8.5 mV/V + 2.3 µV 2.4 mV/V 0.87 mV/V 1.1 mV/V + 2.3 µV 2.0 mV/V + 2.3 µV 3.8 mV/V + 2.3 µV 8.1 mV/V + 2.3 µV 2.3 mV/V 0.84 mV/V 1.1 mV/V + 2.3 µV 2.0 mV/V + 2.3 µV 3.8 mV/V + 2.3 µV 8.5 mV/V + 2.3 µV Fluke 5730A
to 1.1 mV
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 7 of 31 Parameter/Range Frequency CMC 2, 4 (±) Comments AC Voltage – Generate3 (cont) Wideband Output: 330 mV to 1.1 V (1.1 to 3.5) V (1 to 85) kV (10 to 30) Hz 30 Hz to 120 kHz (0.12 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (10 to 30) Hz 30 Hz to 120 kHz (0.12 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz 60 Hz 2.3 mV/V 0.84 mV/V 1.0 mV/V + 2.3 µV 2.0 mV/V + 2.3 µV 3.8 mV/V + 2.3 µV 8.5 mV/V + 2.3 µV 2.3 mV/V 0.84 mV/V 1.0 mV/V + 2.3 µV 2.0 mV/V + 2.3 µV 3.8 mV/V + 2.3 µV 8.5 mV/V + 2.3 µV 5.9 mV/V Fluke 5720A Ross 120 kV divider w/ 34401A AC Current – Generate3 (1 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.24 mA/A + 16 nA 0.16 mA/A + 9.3 nA 0.10 mA/A + 7.8 nA 0.27 mA/A + 12 nA 1.0 mA/A + 62 nA 0.24 mA/A + 39 nA 0.16 mA/A + 31 nA 0.10 mA/A + 31 nA 0.20 mA/A + 0.10 µA 1.0 mA/A + 0.62 µA 0.24 mA/A + 0.39 µA 0.16 mA/A + 0.31 µA 0.10 mA/A + 0.31 µA 0.19 mA/A + 0.54 µA 1.0 mA/A + 4.7 µA 0.24 mA/A + 3.9 µA 0.16 mA/A + 3.1 µA 0.10 mA/A + 2.3 µA 0.19 mA/A + 3.1 µA 1.0 mA/A + 9.3 µA Fluke 5730A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 8 of 31 Parameter/Range Frequency CMC 2, 4, 6 (±) Comments AC Current – Generate3 (cont) (0.22 to 2.2) A (2.2 to 11) A Up to 329.99 µA (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (11 to 20.5) A Clamp-On Only: (10 to 149.999) A (150 to 1025) A 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 30) kHz (10 to 30) kHz (10 to 30) kHz (10 to 45) Hz (10 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.24 mA/A + 31 µA 0.40 mA/A + 78 µA 6.2 mA/A + 0.16 mA 0.40 mA/A + 0.13 mA 0.76 mA/A + 0.29 mA 2.8 mA/A + 0.58 mA 12 mA/A + 0.31 μA 7.8 mA/A + 0.47 μA 3.3 mA/A + 3.1 μA 3.1 mA/A + 0.16 mA 1.4 mA/A + 78 μA 1.4 mA/A + 78 μA 0.95 mA/A + 3.9 mA 1.2 mA/A + 3.9 mA 23 mA/A + 3.9 mA 0.31 % 0.81 % 0.33 % 0.82 % Fluke 5730A Fluke 5730A w/ 5725A Fluke 5522A Fluke 5522A w/coil AC Voltage – Measure Up to 199.99 mV (0.2 to 1.9999) V (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 0.35 mV/V + 14 µV 0.16 mV/V + 4.0 µV 0.12 mV/V + 4.0 µV 0.12 mV/V + 2.0 µV 0.14 mV/V + 4.0 µV 0.35 mV/V + 8.0 µV 0.77 mV/V + 20 µV 0.50 mV/V + 0.12 mV 0.12 mV/V + 20 µV 0.11 mV/V + 20 µV 79 µV/V + 20 µV 0.11 mV/V + 20 µV 0.23 mV/V + 40 µV 0.59 mV/V + 0.20 mV 3.0 mV/V + 2.0 mV 10 mV/V + 20 mV Fluke 8508A
9--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 9 of 31 Parameter/Range Frequency CMC 2, 4 (±) Comments AC Voltage – Measure (cont) (2 to 19.999) V (20 to 199.99) V (100 to 1050) V (1 to 85) kV (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 10) Hz (10 to 40) Hz (40 to 10) kHz (10 to 30) kHz (30 to 100) kHz 60 Hz 0.36 mV/V + 1.2 mV 0.13 mV/V + 0.20 mV 95 µV/V + 0.20 mV 85 µV/V + 0.20 mV 0.11 mV/V + 0.20 mV 0.22 mV/V + 0.40 mV 0.58 mV/V + 2.0 mV 3.0 mV/V + 20 mV 10 mV/V + 0.20 V 0.43 mV/V + 12 mV 0.13 mV/V + 2.0 mV 98 µV/V + 2.0 mV 83 µV/V + 2.0 mV 0.12 mV/V + 2.0 mV 0.22 mV/V + 4.0 mV 0.58 mV/V + 20 mV 1.6 mV/V + 0.2 V 5.2 mV/V + 2.0 V 0.50 mV/V + 10 mV 0.13 mV/V + 20 mV 0.16 mV/V + 20 mV 0.38 mV/V + 40 mV 0.66 mV/V + 0.20 V 5.9 mV/V Fluke 8508A Ross 120 kV divider w/ 34401A AC Current – Measure3 Up to 199.99 µA (0.2 to 1.9999) mA (2 to 19.999) mA (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 0.58 mA/A + 20 nA 0.52 mA/A + 20 nA 0.65 mA/A + 20 nA 3.1 mA/A + 20 nA 0.42 mA/A + 0.20 µA 0.31 mA/A + 0.20 µA 0.63 mA/A + 0.20 µA 3.1 mA/A + 0.20 µA 0.41 mA/A + 2.0 µA 0.31 mA/A + 2.0 µA 0.63 mA/A + 2.0 µA 3.7 mA/A + 2.0 µA Fluke 8508A
2 to 19.999 V
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 10 of 31 Parameter/Range Frequency CMC 2, 4, 6 (±) Comments AC Current – Measure3 (cont) (20 to 199.99) mA (0.2 to 1.9999) A (20 to 19.999) A With Shunts: (20 to 100) A (100 to 300) A (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz (1 to 10) Hz 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz 60 Hz 60 Hz 0.42 mA/A + 20 µA 0.30 mA/A + 20 µA 0.68 mA/A + 20 µA 0.57 mA/A + 0.20 mA 0.85 mA/A + 0.20 mA 2.4 mA/A + 0.20 mA 0.74 mA/A + 0.20 mA 2.1 mA/A + 0.20 mA 040 µA/A + 390 mA 0.41 mA/A + 230 mA Fluke 8508A 3458A w/ various shunts Capacitance – Generate 3 (0.19 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz DC to 50 Hz DC to 20 Hz DC to 6 Hz DC to 2 Hz DC to 0.6 Hz DC to 0.2 Hz 4.0 mF/F + 7.8 pF 4.0 mF/F + 7.8 pF 2.1 mF/F + 7.8 pF 2.1 mF/F + 78 pF 2.0 mF/F + 0.23 nF 2.1 mF/F + 0.78 nF 2.1 mF/F + 2.3 nF 2.1 mF/F + 7.8 nF 3.2 mF/F + 23 nF 3.6 mF/F + 78 nF 3.5 mF/F + 0.23 µF 3.5 mF/F + 0.78 µF 3.5 mF/F + 2.3 µF 3.5 mF/F + 7.8 µF 5.8 mF/F + 23 µF 8.5 mF/F + 78 µF Fluke 5522A AC Level Flatness3 – (0.5, 1, 3) Vrms Thermal Converter 10 Hz to < 30 kHz (30 to < 100) kHz (0.1 to < 1) MHz (1 to < 3) MHz (3 to < 8) MHz (8 to < 20) MHz (20 to < 30) MHz (30 to < 50) MHz (50 to < 70) MHz (70 to < 80) MHz (80 to < 100) MHz 100 MHz 0.12 % 0.23 % 0.29 % 0.58 % 0.70 % 0.71 % 0.76 % 1.8 % 2.8 % 3.6 % 3.9 % 4.8 % By comparison to thermal voltage converters w/ HP 3458A OPT 002
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 11 of 31 Parameter/Equipment Range CMC 2, 4, 6 (±) Comments Oscilloscopes – Amplitude DC Signal: 50 Ω Load 1 MΩ Load Amplitude Square Wave: 10 Hz to 10 kHz: 50 Ω Load 1 MΩ Load Bandwidth / Level Sine Flatness 3 Time Marker Rise Time – Generate Resistance 0 V to ± 6.6 V 0 V to ± 130 V 1 mV to ± 6.0 V p-p 10 Hz to 10 kHz 1 mV to ± 200 Vp-p 10 Hz to 10 kHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz (1.1 to 18) GHz (18 to 26.5) GHz (26.5 to 50) GHz 1 ns to 20 ms 50 ms to 5 s Non-cardinal point 1 kHz to 2 MHz, (200 to 300) ps (2 to 10) MHz, (200 to 350) ps (40 to 60) Ω (0.6 to 1.5) MΩ 1.9 mV/V + 31 µV 0.39 mV/V + 31 µV 2.1 mV/V + 31 µV 0.78 mV/V + 31 µV 2.9 % 3.1 % 4.1 % 4.7 % 4.0 % 4.1 % 7.2 % 2.5 μs/s (19 + 38t) μs/s 39 μs/s 19 ps 19 ps 0.79 mΩ/Ω 0.79 mΩ/Ω Fluke 5522A Power meter & sensor with signal generator Fluke 5522A t = time in seconds Electrical Calibration of Thermocouple Indicators3 – Type B Type C (600 to 800) °C (800 to 1550) °C (1550 to 1820) °C (0 to 1000) °C (1000 to 1800) °C (1800 to 2000) °C (2000 to 2316) °C 0.29 °C 0.24 °C 0.20 °C 0.16 °C 0.21 °C 0.22 °C 0.29 °C Fluke 7526A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 12 of 31 Parameter/Equipment Range CMC 2 (±) Comments Electrical Calibration of Thermocouple Indicators3 – (cont) Type E Type J Type K Type L Type N Type R Type S (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 600) °C (600 to 1000) °C (-210 to -100) °C (-100 to 800) °C (800 to 1200) °C (-250 to -200) °C (-200 to -100) °C (-100 to 500) °C (500 to 800) °C (800 to 1372) °C (-200 to -100) °C (-100 to 900) °C (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 100) °C (100 to 800) °C (800 to 1300) °C (-50 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1600) °C (1600 to 1767) °C (-50 to -25) °C (-25 to 0) °C (0 to 100) °C (100 to 400) °C (400 to 600) °C (600 to 1000) °C (1000 to 1600) °C (1600 to 1767) °C 0.22 °C 0.14 °C 0.12 °C 0.12 °C 0.13 °C 0.20 °C 0.13 °C 0.13 °C 0.37 °C 0.16 °C 0.13 °C 0.13 °C 0.14 °C 0.13 °C 0.12 °C 0.57 °C 0.21 °C 0.14 °C 0.13 °C 0.13 °C 0.14 °C 0.44 °C 0.37 °C 0.32 °C 0.24 °C 0.20 °C 0.19 °C 0.18 °C 0.21 °C 0.41 °C 0.37 °C 0.31 °C 0.25 °C 0.21 °C 0.20 °C 0.20 °C 0.23 °C Fluke 7526A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 13 of 31 Parameter/Equipment Range CMC 2 (±) Comments Electrical Calibration of Thermocouple Indicators3 – (cont) Type T Type U (-250 to -200) °C (-200 to -100) °C (-100 to 0) °C (0 to 200) °C (200 to 400) °C (-200 to 0) °C (0 to 200) °C (200 to 600) °C 0.30 °C 0.16 °C 0.13 °C 0.12 °C 0.12 °C 0.17 °C 0.13 °C 0.13 °C Fluke 7526A Electrical Calibration of RTDs3 – PT 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω (-200 to -800) °C (-200 to 630) °C (-200 to 630) °C (JIS) (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.044 °C 0.044 °C 0.044 °C 0.041 °C 0.043 °C 0.044 °C 0.051 °C 0.098 °C 0.11 °C 0.11 °C 0.13 °C 0.036 °C 0.043 °C 0.044 °C 0.051 °C 0.066 °C 0.066 °C 0.073 °C 0.088 °C 0.029 °C 0.029 °C 0.036 °C 0.042 °C 0.050 °C 0.18 °C 0.057 °C 0.18 °C Fluke 7526A Fluke 5520A
14propagation of uncertainty method--
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 15 of 31 Parameter/Equipment Range CMC2, 4, 6 (±) Comments AC Power – Generate 3 PF = (0 to 1) (cont) (45 to 65) Hz 1.09 mW to 9.2 W 2.97 mW to 33.6 W 10.9 mW to 91.8 W 29.7 mW to 336.6 W 108.9 mW to 918 W 297 mW to 2244 W 72.6 mW to 4590 W (1.49 W to 20 910) W 65 Hz to 1 kHz (0.109 to 3.0) mW (0.297 to 10.89) mW (1.09 to 29.7) mW (3.0 to 108.9) mW 65 Hz to 1 kHz (10.9 to 297) mW (29.7 to 726) mW 72.6 mW to 1.5 W 148.5 mW to 6.8 W 1.089 mW to 9.179 W 2.97 mW to 33.659 W 10.89 mW to 91.7898 W (0.0297 to 336.5898) W (0.1089 to 917.898) W (0.297 to 2243.898) W (0.726 to 4589.898) W 1.485 W to 20.91 kW (1 to 5) kHz (0.1089 to 2.9696) mW (0.297 to 10.8893) mW (1.089 to 29.6958) mW (2.97 to 108.8934) mW (10.89 to 296.958) mW (29.7 to 725.945) mW (72.6 to 1484.922) mW 148.5 mW to 6.7648 W 330 mV to 1020 V (3.3 to 8.999) mA (9 to 32.999) mA (33 to 89.99) mA (90 to 329.99) mA (330 to 899.9) mA (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A (33 to 329.99) mV (3.3 to 8.999) mA (9 to 32.999) mA (33 to 89.99) mA (90 to 329.99) mA (33 to 329.99) mV (330 to 899.9) mA (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A 330 mV to 1020 V (3.3 to 8.999) mA (9 to 32.999) mA (33 to 89.99) mA (90 to 329.99) mA (330 to 899.9) mA (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A (33 to 329.99) mV (3.3 to 8.999) mA (9 to 32.999) mA (33 to 89.99) mA (90 to 329.99) mA (330 to 899.9) mA (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A 0.34 % 0.062 % 0.094 % 0.062 % 0.086 % 0.071 % 0.094 % 0.077 % 0.040 % 0.040 % 0.042 % 0.039 % 0.54 % 0.053 % 0.094 % 0.14 % 0.043 % 0.043 % 0.045 % 0.042 % 0.54 % 0.055 % 0.095 % 0.14 % 0.10 % 0.10 % 0.12 % 0.12 % 0.54 % 0.50 % 0.12 % 0.16 % Fluke 5522A
16--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 16 of 31 Parameter/Equipment Range CMC2, 4, 6 (±) Comments AC Power – Generate 3 PF = (0 to 1) (cont) (1 to 5) kHz 1.089 mW to 9.179 W 2.97 mW to 33.659 W 10.89 mW to 91.7898 W (0.0297 to 336.5898) W (0.1089 to 917.898) W (0.297 to 2243.898) W (0.726 to 4589.898) W 1.485 W to 20.91 kW (5 to 10) kHz (0.1089 to 2.9696) mW (0.297 to 10.8893) mW (1.089 to 29.6958) mW (2.97 to 108.8934) mW (10.89 to 296.958) mW (29.7 to 725.945) mW (72.6 to 989.9667) mW (5 to 10) kHz 1.089 mW to 9.179 W 2.97 mW to 33.659 W 10.89 mW to 91.7898 W 29.7 mW to 336.5898 W (0.1089 to 917.898) W (0.297 to 2243.898) W (0.726 to 3059.9898) W (10 to 30) kHz (0.1089 to 2.9696) mW (0.297 to 10.8893) mW (1.089 to 29.6958) mW (2.97 to 108.8934) mW 1.089 mW to 9.179 W 2.97 mW to 33.659 W 10.89 mW to 91.7898 W 29.7 mW to 336.5898 W 330 mV to 1020 V (3.3 to 8.999) mA (9 to 32.999) mA (33 to 89.99) mA (90 to 329.99) mA (330 to 899.9) mA (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A (33 to 329.99) mV (3.3 to 8.999) mA (9 to 32.999) mA (33 to 89.99) mA (90 to 329.99) mA (330 to 899.9) mA (0.9 to 2.1999) A (2.2 to 2.999 99) A 330 mV to 1020 V (3.3 to 8.999) mA (9 to 32.999) mA (33 to 89.99) mA (90 to 329.99) mA (330 to 899.9) mA (0.9 to 2.1999) A (2.2 to 2.999 99) A (33 to 329.99) mV (3.3 to 8.999) mA (9 to 32.999) mA (33 to 89.99) mA (90 to 329.99) mA 330 mV to 1020 V (3.3 to 8.999) mA (9 to 32.999) mA (33 to 89.99) mA (90 to 329.99) mA 0.10 % 0.10 % 0.12 % 0.12 % 0.54 % 0.50 % 0.12 % 0.16 % 0.34 % 0.34 % 0.35 % 0.34 % 0.61 % 0.57 % 0.57 % 0.33 % 0.34 % 0.34 % 0.36 % 0.35 % 0.61 % 0.57 % 1.2 % 1.2 % 1.2 % 1.2 % 1.2 % 1.2 % 1.3 % 1.3 % Fluke 5522A Power Supplies – Measure 3 Ripple / Noise RMS - CV Ripple / Noise RMS - CC Transient Response Time Voltage Up to 1000 V Up to 50 A Up to 5 ms Up to 1 V 59 µV/V 59 µA/A 2 ms/s 8.3 mV/V Tektronix MDO3014 with load Tektronix MDO3014 with load
to 1020 V
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 17 of 31 III. Electrical – RF / Microwave Parameter/Range Frequency CMC2, 4, 6 (±) Comments RF Power – Measure 3 1 mW Power Meter Reference 50 MHz 0.26 % HP 478A-H76 w/ HP 432A & DMM Thermistor Mount Calibration – Calibration Factor 3 50 MHz reference (9 to 50) kHz (50 to 100) kHz (0.1 to 2000) MHz (2.0 to 4.2) GHz (4.2 to 10.0) GHz (10.0 to 11.0) GHz (11.0 to 18.0) GHz 0.85 % 0.68 % 0.92 % 0.86 % 0.88 % 0.92 % 0.96 % 1.0 % Tegam 2505A/1830A, Agilent EPM 441A Power Sensor Calibration – Calibration Factor 3 (10 to 50) MHz (50 to 80) MHz (0.08 to 2.7) GHz (2.7 to 4.6) GHz (4.6 to 5.6) GHz (5.6 to 9.2) GHz (9.2 to 11.4) GHz (11.4 to 12.4) GHz (12.4 to 13.25) GHz (13.25 to 19) GHz (19 to 22) GHz (22 to 29) GHz (29 to 34) GHz (34 to 39) GHz (39 to 43) GHz (43 to 49) GHz 49 GHz 50 GHz 1.5 % 1.0 % 1.1 % 1.2 % 1.3 % 1.4 % 1.5 % 1.6 % 1.7 % 1.8 % 1.9 % 2.4 % 2.7 % 3.0 % 3.5 % 3.9 % 4.4 % 4.7 % Tegam 2505A/1830A, Agilent EPM 441A Reflection Coefficient 3 (Into 50 Ω) – 0 < ρ ≤ 0.2 0.2 < ρ ≤ 0.4 0.4 < ρ ≤ 0.6 30 kHz to 1.2 GHz (1.2 to 3) GHz (3 to 6) GHz 30 kHz to 1.2 GHz (1.2 to 3) GHz (3 to 6) GHz 30 kHz to 1.2 GHz (1.2 to 3) GHz (3 to 6) GHz 0.0019 ρ 0.0028 ρ 0.0053 ρ 0.0022 ρ 0.0031 ρ 0.0056 ρ 0.0027 ρ 0.0035 ρ 0.0062 ρ Agilent 8753D/ Agilent 85032B
18--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 18 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments Reflection Coefficient 3 (Into 50 Ω) – (cont) 0.6 < ρ ≤ 0.8 0.8 < ρ ≤ 1 0.000 < ρ ≤ 0.0476 0.0476 < ρ ≤ 0.1111 0.1111 < ρ ≤ 0.200 0.200 < ρ ≤ 0.3333 0.3333 < ρ ≤ 0.500 30 kHz to 1.2 GHz (1.2 to 3) GHz (3 to 6) GHz 30 kHz to 1.2 GHz (1.2 to 3) GHz (3 to 6) GHz 40 MHz to 2 GHz (> 2 to 20) GHz (> 20 to 40) GHz (> 40 to 50) GHz 40 MHz to 2 GHz (> 2 to 20) GHz (> 20 to 40) GHz (> 40 to 50) GHz 40 MHz to 2 GHz (> 2 to 20) GHz (> 20 to 40) GHz (> 40 to 50) GHz 40 MHz to 2 GHz (> 2 to 20) GHz (> 20 to 40) GHz (> 40 to 50) GHz 40 MHz to 2 GHz (> 2 to 20) GHz (> 20 to 40) GHz (> 40 to 50) GHz 0.0033 ρ 0.0042 ρ 0.0078 ρ 0.004 ρ 0.005 ρ 0.0091 ρ 0.0094 ρ 0.0095 ρ 0.018 ρ 0.021 ρ 0.013 ρ 0.013 ρ 0.021 ρ 0.026 ρ 0.014 ρ 0.014 ρ 0.024 ρ 0.031 ρ 0.016 ρ 0.017 ρ 0.028 ρ 0.038 ρ 0.019 ρ 0.02 ρ 0.034 ρ 0.049 ρ Agilent 8753D/ Agilent 85032B Anritsu 37397C/ HP 85056A Anritsu 37397C / HP 85054B/85052B/85056A RF Power – Generate & Measure 3 (-30 to +30) dBm (-70 to -30) dBm (-35 to + 20) dBm 3 Hz to 100 kHz (0.1 to 100) MHz 100 MHz to 2.4 GHz (2.4 to 8.0) GHz (8.0 to 12.4) GHz (12.4 to 18.0) GHz (18.0 to 26.5) GHz (26.5 to 33.0) GHz (33.0 to 40.0) GHz (40.0 to 44.0) GHz (44.0 to 50.0) GHz 0.060 dB 0.091 dB 0.027 dBm 0.042 dBm 0.064 dBm 0.082 dBm 0.11 dBm 0.098 dBm 0.11 dBm 0.11 dBm 0.14 dBm 0.14 dBm HP 33250A / 3458A Signal generator & power meter w/ power sensor: NRP50T w/ power meter
to 1
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 19 of 31 Parameter/Range Frequency CMC2, 4, 6 (±) Comments RF Power – Generate3 (-56 to 27) dBm (20 to 24) dBm (14 to 20) dBm (-17 to 14) dBm (-48 to -17) dBm (-74 to -48) dBm (-84 to -74) dBm (-94 to -84) dBm (-130 to -94) dBm DC to 5 MHz (> 5 to 20) MHz Up to 100 kHz (0.1 to 128) MHz Up to 100 kHz (0.1 to 128) MHz (128 to 300) MHz (0.3 to 1.4) GHz Up to 100 kHz (0.1 to 128) MHz (128 to 300) MHz (0.3 to 1.4) GHz (1.4 to 4.0) GHz Up to 100 kHz (0.1 to 128) MHz (128 to 300) MHz (0.3 to 1.4) GHz (1.4 to 3) GHz (3 to 4) GHz (0.1 to 10) MHz (10 to 300) MHz (0.3 to 1.4) GHz (1.4 to 4) GHz (0.1 to 10) MHz (10 to 128) MHz (128 to 300) MHz (0.3 to 1.4) GHz (1.4 to 4) GHz (0.1 to 10) MHz (10 to 128) MHz (128 to 300) MHz (0.3 to 3) GHz (10 to 128) MHz 128 MHz to 1.4 GHz 0.19 dB 0.35 dB 0.024 dB 0.048 dB 0.024 dB 0.046 dB 0.064 dB 0.16 dB 0.024 dB 0.051 dB 0.064 dB 0.16 dB 0.25 dB 0.024 dB 0.051 dB 0.064 dB 0.17 dB 0.25 dB 0.41 dB 0.16 dB 0.086 dB 0.32 dB 0.41 dB 0.39 dB 0.089 dB 0.24 dB 0.40 dB 0.80 dB 0.40 dB 0.24 dB 0.39 dB 0.80 dB 0.58 dB 1.3 dB Tektronix AFG2021 Fluke 96270A/LL/FF w/leveling head RF Power – Generate (Microwave Output) Up to 100 MHz (0.1 to 1) GHz (1 to 2.4) GHz (2.4 to 8) GHz (8 to 12) GHz (12 to 18 GHz (18 to 22 GHz (22 to 26.5) GHz 0.43 % 0.57 % 0.70 % 0.88 % 1.0 % 1.2 % 1.6 % 2.5 % Fluke 96270A/LL/FF w/leveling head
20--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 20 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments RF Attenuation – Tuned RF Power Measure 3 (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -95) dB (-95 to -100) dB (-100 to -105) dB (-105 to -110) dB (-110 to -115) dB (-115 to -120) dB (-120 to -125) dB (0 to -5) dB (-5 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -85) dB (-85 to -90) dB (-90 to -100) dB (-100 to -105) dB (-105 to -110) dB (-110 to -115) dB (-115 to -120) dB (-120 to -130) dB (-130 to -135) dB 100 kHz to 10 MHz 10 MHz to 22 GHz 0.018 dB 0.024 dB 0.029 dB 0.035 dB 0.041 dB 0.047 dB 0.052 dB 0.058 dB 0.064 dB 0.071 dB 0.075 dB 0.086 dB 0.094 dB 0.13 dB 0.21 dB 0.27 dB 0.018 dB 0.019 dB 0.024 dB 0.029 dB 0.035 dB 0.041 dB 0.047 dB 0.053 dB 0.059 dB 0.065 dB 0.068 dB 0.074 dB 0.082 dB 0.092 dB 0.094 dB 0.22 dB 0.47 dB 1.3 dB Rohde & Schwarz R&S FSMR3050
0 to -5 dB
21--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 21 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments RF Attenuation – Tuned RF Power Measure 3 (cont) (0 to -5) dB (-5 to -10) dB (-10 to -15) dB (-15 to -20) dB (-20 to -25) dB (-25 to -30) dB (-30 to -35) dB (-35 to -40) dB (-40 to -45) dB (-45 to -50) dB (-50 to -55) dB (-55 to -60) dB (-60 to -65) dB (-65 to -70) dB (-70 to -75) dB (-75 to -80) dB (-80 to -85) dB (-85 to -90) dB (-90 to -95) dB (-95 to -100) dB (-100 to -105) dB (-105 to -110) dB (-110 to -115) dB (-115 to -120) dB (-120 to -130) dB (-130 to -135) dB (0 to -5) dB (-5 to -20) dB (-10 to -15) dB (-15 to -20) dB (-20 to -25) dB (-25 to -30) dB (-30 to -35) dB (-35 to -40) dB (-40 to -45) dB (-45 to -50) dB (-50 to -55) dB (-55 to -60) dB (-60 to -65) dB (-65 to -70) dB (-70 to -75) dB (-75 to -80) dB (-80 to -85) dB (-85 to -90) dB (22 to 26.5) GHz (26.5 to 40) GHz 0.22 dB 0.28 dB 0.35 dB 0.34 dB 0.30 dB 0.21 dB 0.31 dB 0.26 dB 0.35 dB 0.41 dB 0.35 dB 0.32 dB 0.51 dB 0.38 dB 0.23 dB 0.27 dB 0.34 dB 0.31 dB 0.30 dB 0.27 dB 0.27 dB 0.31 dB 0.45 dB 0.31 dB 2.9 dB 1.3 dB 0.26 dB 0.25 dB 0.25 dB 0.25 dB 0.39 dB 0.29 dB 0.22 dB 0.44 dB 0.31 dB 0.45 dB 0.61 dB 0.41 dB 0.51 dB 0.41 dB 0.29 dB 0.41 dB 0.42 dB 0.41 dB Rohde & Schwarz R&S FSMR3050
0 to -5 dB
22

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 22 of 31 Parameter/Range Frequency CMC2, 4, 6 (±) Comments RF Attenuation – Tuned RF Power Measure 3 (cont) (-90 to -95) dB (-95 to -100) dB (-100 to -105) dB (-105 to -110) dB (-110 to -115) dB (-115 to -120) dB (-120 to -125) dB (0 to -5) dB (-5 to -10) dB (-10 to -15) dB (-15 to -20) dB (-20 to -25) dB (-25 to -30) dB (-30 to -35) dB (-35 to -40) dB (-40 to -45) dB (-45 to -50) dB (-50 to -55) dB (-55 to -65) dB (-60 to -65) dB (-65 to -70) dB (-70 to -75) dB (-75 to -80) dB (-80 to -85) dB (-85 to -90) dB (-90 to -95) dB (-95 to -100) dB (-100 to -105) dB (-105 to -110) dB (-110 to -115) dB (26.5 to 40) GHz (40 to 50) GHz 0.42 dB 0.40 dB 0.38 dB 0.47 dB 0.55 dB 0.18 dB 0.26 dB 0.36 dB 0.31 dB 0.45 dB 0.44 dB 0.50 dB 0.52 dB 0.51 dB 0.55 dB 0.43 dB 0.49 dB 0.30 dB 0.36 dB 0.36 dB 0.44 dB 0.35 dB 0.42 dB 0.36 dB 0.41 dB 0.37 dB 0.38 dB 0.39 dB 0.37 dB 0.35 dB Rohde & Schwarz R&S FSMR3050 Amplitude Modulation – Generate/Measure 3 Rate: 10 Hz to 10 kHz Depth: (5 to 99) % Rate: 10 Hz to 50 kHz Depth: (5 to 99) % Rate: 50 kHz to 100 kHz Depth: (5 to 99) % Rate: 90 Hz to 150 Hz Depth: (5 to 99) % (0.1 to 10) MHz (0.01 to 50) GHz (0.01 to 50) GHz (0.01 to 50) GHz 1.5 % 1.0 % 1.5 % 0.42 % HP 83650B monitored by Rohde & Schwarz R&S FSMR3050
23

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 23 of 31 Parameter/Range Frequency CMC 2, 4, 6 (±) Comments Frequency Modulation – Measure 3 Rate: 10 Hz to 10 kHz Dev: ≤ 50 kHz peak Rate: 10 Hz to 100 kHz Dev: ≤ 500 kHz peak Rate: (100 to 200) kHz Dev: ≤ 500 kHz peak (0.1 to 10) MHz (0.01 to 50) GHz (0.01 to 50) GHz 1.2 % 1.2 % 3.5 % R&S FSMR3050 Phase Modulation – Measure3 Rate: 10 Hz to 10 kHz Rate: 10 Hz to 5 MHz 200 kHz to 10 MHz 10 MHz to 50 GHz 1.0 % 1.0 % R&S FSMR3050 Phase Noise – Measure 3 Carrier Frequency: (1 to 10) MHz (-40 to -176) dBc 1 Hz Offset 10 Hz Offset 100 Hz Offset 1 kHz Offset 10 kHz Offset 100 kHz Offset 1 MHz Offset 2.7 dB 2.5 dB 1.6 dB 1.6 dB 1.6 dB 1.6 dB 4.0 dB R&S FSMR3050 Phase Noise – Measure3 (10 to 100) MHz (-66 to -175) dBc 1 Hz Offset 10 Hz Offset 100 Hz Offset 1 kHz Offset 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz Offset > 30 MHz Offset 3.7 dB 2.8 dB 1.6 dB 1.6 dB 1.6 dB 1.6 dB 2.7 dB 3.3 dB 4.0 dB R&S FSMR3050
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 24 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments Phase Noise – Measure3 (cont) 100 MHz to 1 GHz (-46 to -173) dBc (1 to 3) GHz (+10 to -170) dBc (3 to 7) GHz (+17 to -166) dBc (7 to 10) GHz (+20 to -175) dBc (10 to 16) GHz (+24 to -171) dBc 1 Hz Offset 10 Hz Offset 100 Hz Offset 1 kHz Offset 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz Offset > 30 MHz Offset 1 Hz Offset 10 Hz Offset 100 Hz Offset 1 kHz Offset 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz Offset > 30 MHz Offset 1 Hz Offset 10 Hz Offset 100 Hz Offset 1 kHz Offset 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz Offset > 30 MHz Offset 1 Hz Offset 10 Hz Offset 100 Hz Offset 1 kHz Offset 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz Offset > 30 MHz Offset 1 Hz Offset 10 Hz Offset 100 Hz Offset 1 kHz Offset 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz Offset > 30 MHz Offset 3.2 dB 2.4 dB 1.7 dB 1.6 dB 1.6 dB 1.6 dB 3.9 dB 4.0 dB 4.0 dB 4.2 dB 2.0 dB 1.6 dB 1.6 dB 1.6 dB 1.6 dB 3.8 dB 4.4 dB 4.1 dB 4.4 dB 2.6 dB 1.7 dB 1.6 dB 1.6 dB 1.6 dB 3.3 dB 3.9 dB 4.6 dB 4.4 dB 2.7 dB 1.8 dB 1.6 dB 1.6 dB 1.6 dB 3.5 dB 3.3 dB 4.6 dB 3.2 dB 2.7 dB 1.7 dB 1.6 dB 1.6 dB 1.6 dB 3.3 dB 4.1 dB 4.0 dB R&S FSMR3050
25--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 25 of 31 Parameter/Range Frequency CMC2, 4 (±) Comments Phase Noise – Measure 3 (cont) (16 to 26.5) GHz (+28 to -167) dBc (26.5 to 50) GHz (+34 to -161) dBc 1 Hz Offset 10 Hz Offset 100 Hz Offset 1 kHz Offset 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz Offset > 30 MHz Offset 1 Hz Offset 10 Hz Offset 100 Hz Offset 1 kHz Offset 10 kHz Offset 100 kHz Offset 1 MHz Offset 10 MHz Offset > 30 MHz Offset 4.1 dB 2.7 dB 1.7 dB 1.6 dB 1.6 dB 1.6 dB 3.6 dB 4.2 dB 4.0 dB 4.1 dB 2.0 dB 1.8 dB 1.6 dB 1.6 dB 1.6 dB 3.7 dB 3.6 dB 4.4 dB R&S FSMR3050 Average Noise & Residuals (DANL) 3 (-30 to -170) dBm 20 Hz to 50 GHz 0.78 dB 50 Ω load 3rd Order Intermodulation 3 (0 to -120) dB (0 to -120) dB 200 Hz to 50 MHz 50 MHz to 50 GHz 2.1 dB 3.0 dB Fluke 96270A, Agilent 83650B 2nd Harmonic Distortion3 (0 to -120) dB (0 to -120) dB 200 Hz to 50 MHz 50 MHz to 50 GHz 2.8 dB 3.8 dB Fluke 96270A, Agilent 83650B
to 50 GHz
26--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 26 of 31 Parameter/Range Frequency CMC2, 4, 6 (±) Comments Digital Modulation – Measure 3 Carrier: 2 MHz to 50 GHz Error Vector Magnitude for Modulation Phase Error for Modulation Symbol Rate ≤ 1 MHz ≤ 10 MHz ≤ 15 MHz Mod Freq Span ≤ 100 kHz ≤ 1 MHz ≤ 10 MHz > 10 MHz 0.53 % 1.1 % 2.1 % 0.32° 0.42° 0.64° 1.3° Rohde & Schwarz R&S FSMR3050 Types: 2FSK & 4FSK (include GFSK), BPSK, QPSK (3GPP WCDMA, CDMA2000®), OQPSK, DQPSK, π/4 DQPSK, 8PSK, D8PSK, 3 π/8 8PSK (EDGE), 16QAM, 32QAM, 64QAM, 128QAM, 256 QAM, D16QAM, D32QAM, D64QAM, D128QAM, D256QAM, 8VSB, GSM, NADC, PDC, PHS, Bluetooth®, DECT, TETRA Distortion– Measure Fundamental Frequency 3 20 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz Amplitude Modulation Distortion Depth of Modulation: 5 % to 99 % Frequency Modulation Distortion Deviation < 10 kHz Deviation < 50 kHz Deviation < 100 kHz Deviation < 500 kHz Phase Modulation Distortion Distortion – Audio Input (-100 to 0) dB (-80 to 0) dB (-70 to 0) dB (-65 to 0) dB Carrier Frequency: 100 kHz to 10 MHz ≥ 10 MHz to 4 GHz 200 kHz to 10 MHz ≥ 10 MHz to 4 GHz 200 kHz to 10 MHz ≥ 10 MHz to 4 GHz 100 Hz to 100 kHz 1.2 dB 2.3 dB 2.3 dB 0.36 % 0.44 % 0.19 % 0.38 % 0.20 % 0.38 % 0.18 % 0.18 % 0.60 dB HP 8903B R&S FSMR3050
2 to 50 MHz to GHz
27

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 27 of 31 IV. Mechanical Parameter/Equipment Range CMC2 (±) Comments Scales & Balances 3 (5 to 10) mg (10 to 20) mg (20 to 50) mg (50 to 100) mg (100 to 200) mg (0.2 to 0.5) g (0.5 to 1) g (1 to 2) g (2 to 3) g (3 to 5) g (5 to 10) g (10 to 50) g (50 to 100) g (100 to 200) g (200 to 300) g (300 to 500) g (0.5 to 1) kg (1 to 2) kg (2 to 3) kg (3 to 3.5) kg (0.25 to 1) lb ((113.398 to 453.592) g) (1 to 10) lb ((453.592 to 4535.92) g) (10 to 25) lb (4535.92 g to 11.3398 kg) (25 to 50) lb ((11.3398 to 22.6796) kg) (50 to 100) lb ((22.6796 to 45.3952) kg) (100 to 250) lb ((45.3592 to 113.398) kg) (250 to 500) lb ((113.398 to 226.796) kg) 16 µg 16 µg 16 µg 29 µg 29 µg 29 µg 65 µg 65 µg 130 µg 73 µg 87 µg 0.15 mg 0.3 mg 0.65 mg 0.98 mg 1.6 mg 2.9 mg 6.1 mg 9.1 mg 14 mg 44 mg 0.44 g 0.65 g 26 g 27 g 29 g 35 g Class S1 weights Class F weights Mass (1 to 20) mg 30 mg (50 to 200) mg 300 mg 500 mg 1 g 2 g 3 g 5 g 10 g 20 g 30 g 50 g 100 g 14 µg 14 µg 14 µg 14 µg 14 µg 41 µg 41 µg 42 µg 41 µg 60 µg 87 µg 88 µg 0.14 mg 0.30 mg Class S1 weights using comparison method
28

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 28 of 31 Parameter/Equipment Range CMC2, 5, 6, 8 (±) Comments Mass (cont) 200 g 300 g 500 g 1 kg 2 kg 3 kg 5 kg 20 lb (9.071 85 kg) 50 lb (22.6796 kg) 0.60 mg 0.89 mg 1.4 mg 2.9 mg 5.9 mg 8.7 mg 15 mg 22 mg 60 mg Class S1 weights using comparison method Tachometers (60 to 100 000) RPM 0.0023 RPM + 0.6R Fluke 5522A Torque – Measuring Equipment 3 (10 to 100) ozfꞏin (5 to 50) ozfꞏin (40 to 400) ozfꞏin (100 to 1000) lbfꞏin (25 to 250) lbfꞏft (60 to 600) lbfꞏft (200 to 2000) lbfꞏft 0.59 % 0.30 % 0.30 % 0.30 % 0.30 % 0.29 % 0.31 % 1001-O-DTT CDI 5000 ST w/ 2000-400-02 2000-12-02 2000-14-02 Torque Transducers (2 to 200) ozfꞏin (4 to 110) lbfꞏin (9 to 275) lbfꞏft (275 to 2000) lbfꞏft (2000 to 4000) lbfꞏft 0.045 % 0.046 % 0.052 % 0.046 % 0.061 % Torque arms & wheels w/ NIST Class F weights Pressure – Measuring Equipment (0 to 1) inꞏH2O (1 to 5) inꞏH2O (5 to 10) inꞏH2O (10 to 20) inꞏH2O (20 to 30) inꞏH2O (-14.5 to 0) PSIG (0 to 15) PSIG Up to 75 PSIG (75 to 150) PSIG (0 to 600) PSIG (600 to 1200) PSIG (0 to 1500) PSIG (1500 to 3000) PSIG 0.000 24 inꞏH 2O 0.000 50 inꞏH2O 0.000 97 inꞏH2O 0.0020 inꞏH2O 0.0029 inꞏH2O 0.012 % of FS 0.012 % + 0.0014 PSI 0.012 % of FS 0.013 % 0.013 % of FS 0.013 % 0.013 % of FS 0.013 % Ruska 7250 lp Mensor CPC 6050
29

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 29 of 31 Parameter/Equipment Range CMC2, 6, 8 (±) Comments Pressure – Measuring Equipment (cont) (0 to 15) PSIA (15 to 30) PSIA (0 to 75) PSIA (50 to 150) PSIA (0 to 600) PSIA (600 to 1200) PSIA (0 to 1500) PSIA (1500 to 3000) PSIA (-29 to 0) inꞏHg 0.012 % of FS 0.012 % 0.012 % of FS 0.013 % 0.013 % of FS 0.013 % 0.013 % of FS 0.013 % 0.0019 inꞏHg Mensor CPC 6050 Ruska 7250 xi Pressure – Measuring Equipment (3000 to 10 000) PSI 0.018 % IV Fluke P3214 Gas Flow – Measuring Equipment Up to 10 sccm (10 to 25) sccm (25 to 50) sccm (50 to 75) sccm (75 to 100) sccm (100 to 250) sccm (250 to 500) sccm (500 to 750) sccm (750 to 1000) sccm Up to 5 slm (5 to 10) slm (10 to 20) slm (20 to 30) slm (30 to 40) slm (40 to 50) slm (50 to 100) slm (100 to 150) slm (150 to 200) slm (200 to 300) slm 0.04 sccm 0.1 sccm 0.19 sccm 0.28 sccm 0.37 sccm 0.96 sccm 1.9 sccm 2.8 sccm 3.8 sccm 0.02 slm 0.03 slm 0.08 slm 0.11 slm 0.15 slm 0.19 slm 0.37 slm 0.56 slm 0.75 slm 1.1 slm Fluke Molbloc/Molbox mass flow system V. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Temperature – Measure -196 to 0 °C 0 to 200 °C 200 to 420 °C 420 to 660 °C 0.061 °C 0.061 °C 0.11 °C 0.12 °C Fluke 1595A w/5699 SPRT using comparison method
30

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 30 of 31 Parameter/Equipment Range CMC2, 8 (±) Comments Temperature – Measuring Equipment -196 °C (-80 to -38) °C (-38 to 0.0) °C (0.0 to 50.0) °C (50 to 150) °C (150 to 300) °C (300 to 660) °C 0.027 °C 0.017 °C 0.017 °C 0.017 °C 0.029 °C 0.070 °C 0.41 °C Fluke 1595A w/ 5699 & various baths & dry wells Relative Humidity – Measuring Equipment (10 to 95) % 0.53 % RH Thunder Scientific 2500 Relative Humidity – Measure 3 (12 to 79) % 1.2 % RH Rotronic HP 23A w/ HC 2-S probe VI. Time & Frequency Parameter/Equipment Range CMC 2, 8 (±) Comments Frequency – Measuring Equipment (0.001 to 1000) Hz 1000 Hz to 20 MHz 10 MHz to 50 GHz 0.17 nHz/Hz 0.18 nHz/Hz 0.17 nHz/Hz GPS disciplined oscillator, Tektronix AFG2021 GPS disciplined Frequency – Measure DC to 1.0 kHz (1.0 to 1000) kHz (1.0 to 225) MHz (0.225 to 12.4) GHz (0.5 to 40.0) GHz 0.12 mHz 0.29 nHz/Hz 38 pHz/Hz 39 pHz/Hz 1.2 Hz/GHz Datum 9390 & 53132A Datum 9390 & 5352B Rise Time – Measure 20 ps to 1 ns 21 ps 83487A (RT = 0.35/BW) ____________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
31

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2357.10) Revised 12/03/2025 Page 31 of 31 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, R is the resolution of the device under test. 6 All CMC’s listed in % are percent of reading of input unless otherwise stated. 7 This scope meets A2LA’s P112 Flexible Scope Policy. 8 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
32ISO/IEC 17025:20 17; ANSI/NCSLI Z540-1-1994; ANSI/NCSLI Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1411 North Grand Avenue, Suite 300, Covina, CA, 91724, US

34.08779, -117.88912

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.