3130 Stanton Ct, 29418, N. Charleston, SC, United States

Visit website
A2LA 1387.03ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
23
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 23 scope lines.

A2LA certificate 1387.03 · 23 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994pH buffer standards; Conductivity standards; Brix solutionsSee scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 2 of 22 II. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Angular Devices – Measure5 Up to 90° 0.0044° Vision system Bolt Protrusion Gages Up to 12 in 5.8 μin Vision system Bore Micrometers3 – Point Up to 12 in (34 + 2.7D) μin + 0.6R Master rings Bore Gages (Dial/Digital) (Bore Gage w/ Indicator) Up to 4 in (12 + 2.3D) µin + 0.6R Gage blocks Calipers3 Up to 80 in (21 + 7.4L) µin + 0.6R Long gage blocks, gage blocks Check Masters/Caliper Checkers/Step Gages Up to 24 in Up to 1300 mm (15 + 2.7L) µin (1.4 + 0.0033L) µm Electronic indicator, gage blocks CMM Caliper Gage3 – Internal, External Up to 7.5 in (8.9 + 3.9L) µin + 0.6R Gage blocks Chamfer Check Gages Set Ring Effective Diameter Gage Probe Angle 48 µin + 0.6R 0.0044 ° Chamfer check master, set ring Vision system Coating Thickness Gages (1 to 669) mils 10 μin Master foils, foils/shims, ULM Crimping Tools3 Up to 1.0 in Pull Test 0.0006 in 0.13 lbf Pin gages Force gage
to 90 °
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 3 of 22 Parameter/Equipment Range CMC2, 4 (±) Comments Cylindrical Ring Gages3 Up to 2 in (2 to 17) in (6.2 + 2.6D) µin (2.8 + 4.2D) µin Universal length machine, master rings, gage blocks Cylindrical Disc, Plug, & Pin Gages 3 Up to 32 in Up to 1 in (3.5 + 2.8D) μin (25 + 5.7L) µin Universal length machine, gage blocks Micrometer Depth Step Gages Up to 12 in (13 + 3.2L) µin Electronic indicator amplifier, gage blocks Electronic Indicator Amplifier 3 Up to 0.02 in (6.6 + 140L) µin Gage blocks Height Gages3 Up to 48 in (4.3 + 3.5L) µin + 0.6R Gage blocks, long gage blocks, surface plate Optical Flats Up to 6 in 3.1 μin Master optical flat Sine Bars / Plates – Length Flatness Parallelism Up to 10 in Up to 10 in Up to 10 in 41 µin 28 µin 27 µin LVDT Glass Scales Up to 12 in (40 + 2.9L) µin Vision system Indicators/LVDTs3 Up to 4 in Up to 3.93 in (100 mm) (4.2 + 3.7L) µin + 0.6R (14 + 3.3L) µin Gage blocks Indicator calibrator
to 2 in
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 4 of 22 Parameter/Equipment Range CMC2, 4 (±) Comments Length Standards3 Up to 32 in Up to 1300 mm (5.1 + 2.5L) µin (1.4 + 0.0032L) µm ULM, gage blocks CMM Levels3 Up to 12 in Up to 18 in 45 µin + 0.6R 4 arc sec Surface plate, sine bar, gage blocks Leveling plate, amplifier Micrometers3 – Groove & Specialty (Outside/ Inside/Tubular/Indicating & Snap) Depth Up to 60 in Up to 12 in (5.7 + 3.4L) µin + 0.6R (4.3 + 3.3L) µin + 0.6R Gage blocks Gage locks Indicator Calibrators3 (Mic Head Type) Up to 4 in (6.9 + 3L) µin + 0.6R Gage blocks Parallels Up to 20 in (15 + 1.7L) μin Electronic gage amplifier, surface plate Protractor – Bevel Digital 3 Up to 180° Up to 90° 0.0044° 0.07° + 0.6R Vision system Sine plate, gage blocks Steel Rules3 Up to 3000 mm Up to 12 in Up to 72 in (29 + 0.021L) µm (37 + 1.2L) µin (7.3 + 3.8L) in Linear measurement table Vision system Direct comparison, gage blocks Steel Tapes/Pi Tapes Up to 30.5 m (29 + 0.021L) µm Linear measurement table
to 30.5 m
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 5 of 22 Parameter/Equipment Range CMC2, 4 (±) Comments Thickness & Feeler Gages3 Up to 2 in (5.6 + 1.5L) µin ULM Thread Measuring Wires3 (4 to 120) TPI 5.8 µin ULM Laser Micrometers3 Up to 2 in (12 + 7.9D) µin Master pin gages Screw Thread Micrometer Standards Up to 6 in (29 + 1.3L) μin Vision system Snap Gage3 – Flatness of Anvils Size Up to 3 in Up to 20 in 4.2 μin (5.6 + 2.4L) µin + 0.6R Optical flat Gage blocks Universal Measuring Machines/Bench Micrometers3 Up to 12 in (4.1 + 2.3L) μin Gage blocks Radius Gages Up to 4 in (25 + 18L) µin Vision system Thread Rings8 Up to 4.75 in 170 µin Set using master plug gages Class W NPT Tapered Thread Rings – Standoff Ring Thickness Up to 1.5 in Up to 2.0 in (15 + 0.013L) µin (4.6 + 2.6L) µin Electronic indicator, master NPT plug Universal length machine (ULM)
to 2 in
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 6 of 22 Parameter/Equipment Range CMC2, 4 (±) Comments Video Measurement System3 – X, Y Axis Z Axis Up to 12 in Up to 6 in (120 + 4.2L) μin (9.7 + 1.9L) μin Calibration grid Gage blocks Surface Finish Testers3 (2 to 500) µin 5.3 µin Master surface finish patch Surface Finish Standards3 (2 to 500) µin 5.3 µin Direct comparison to master surface patch Spheres & Balls Up to 6 in (5.6 + 1.8D) μin ULM Thread Plugs3 – Major Diameter Pitch Diameter Step Up to 8 in (4 to 120) TPI Up to 1 in (12 + 1.3D) μin (33 + 2.1D) μin 160 μin ULM ULM, thread measuring wires Gage blocks, uni- micrometer Ultrasonic Thickness Gages3 Up to 4 inches (2.4 + 5.1L) μin + 0.6R Gage blocks II. Dimensional Testing/Calibration5 Parameter/Equipment Range CMC2, 8 (±) Comments Surface Finish5 – Measure (2 to 500) µin 5.3 µin Master surface finish patch
2 to 500 µin
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 7 of 22 Parameter/Equipment Range CMC2, 4, 8 (±) Comments Geometric Measurements5 – 1D, 2D, 3D (X, Y, Z & Volumetric) (Up to 1500) mm (1.4 + 0.0038L) µm CMM 2D Optical Inspection5 – Measure X-Y Angle Up to 315 mm Up to 90° 5.8 μm 0.0044° Vision system Flatness5 – Measure Up to 6 in Up to 20 in Up to 1400 mm 5.0 μin 26 μin (1.4 + 0.0038L) μm Optical flat Electronic indicator amplifier CMM Parallelism5– Measure Up to 20 in (20 + 1.5L) µin Electronic gage amplifier Radius5 – Measure Up to 12 in (25 + 18L) µin Vision system Straightness5 – Measure Up to 12 in (20 + 1.1L) µin Electronic indicator amplifier Angular Devices – Measure 5 Up to 360° 0.0044° Vision system Attribute Gages Up to 12 in Up to 32 in, External Measurement Up to 12 in, Internal Measurement Up to 6 in (73 + 5.9L) µin (6.2 + 2.4L) µin (15 + 2.6L) µin 300 µin Vision system Universal length machine Electronic indicator amplifier, gage blocks, rings, plugs, hand tools
to 1500 mm
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 8 of 22 III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Voltage – Measure3 100 mV 1 V 10V 100V 1000V 11 µV/V + 0.42 µV 3.3 µV/V + 0.38 µV 3.4 µV/V + 1.3 µV 4.8 µV/V + 38 µV 5 µV/V + 580 µV Fluke 8588A DC High Voltage – Measure3 (1 to 9) kV (10 to 90) kV 0.1 V + 0.000 52 V/V 7.7 V + 0.0014 V/V High voltage meter High voltage meter / high voltage probe DC Voltage – Generate3 Up to 220 mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V Up to 329.9999 mV 330 mV to 3.299 V (3.3 to 32.9999) V (30 to 329.9999) V (100 to 1000) V 0.0009 % + 0.47 µV 0.0006 % + 0.9 µV 0.0004 % + 2.9 µV 0.0004 % + 4.1 µV 0.0006 % + 50 µV 0.0008 % + 250 µV 24 µV/V + 1.0 µV 14 µV/V + 2.0 µV 15 µV/V + 20 µV 22 µV/V + 150 µV 22 µV/V + 1.5 mV Fluke 5720A Fluke 5520A DC Current – Measure3 10 µA 100 µA 1.0 mA 10 mA 100 mA 1.0 A 10 A 30 A 35 µA/A + 0.4 nA 12 µA/A + 0.4 nA 11 µA/A + 4.1 nA 15 µA/A + 41 nA 60 µA/A + 1 µA 130 µA/A + 100 µA 240 µA/A + 400 µA 550 µA/A + 4.4 mA Fluke 8588A High Current – Measure3 DC: Up to 60 Hz (1 to 15) A (15 to 100) A (100 to 300) A (300 to 2500) A 0.024 % + 3.0 mA 0.023 % + 24 mA 0.011 % + 36 mA (0.26 + 0.0061X) A Current shunt w/ 6.5 digit voltmeter
to 1000 V
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 9 of 22 Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Current – Generate3 Up to 220 µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A 0.008 % + 6 nA 0.0072 % + 7 nA 0.0073 % + 40 nA 0.093 % + 0.7 nA 0.017 % + 12 nA 0.036 % + 0.48 mA Fluke 5720A w/ 5725A DC Current – Generate3 (1 to 329.999) µA (0.33 to 3.299 99) mA (3.3 to 32.9999) mA (33 to 329.999) mA (0.33 to 1.099 99) A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (10 to 16.499) A (16.5 to 149.999) A (150 to 950) A 0.018 % + 20 nA 0.012 % + 50 nA 0.013 % + 250 nA 0.015 % + 3.0 µA 0.025 % + 40 µA 0.046 % + 40 µA 0.06 % + 500 µA 0.12 % + 750 µA 0.67 A (0.67 + 0.0069X) A (1.3 + 0.0022X) A Fluke 5520A Fluke 5520A w/ Fluke 5500A coil Resistance – Measure3 1.9 Ω 19 Ω 190 Ω 1.9 kΩ 19 kΩ 190 kΩ 1.9 MΩ 19 MΩ 100 MΩ 1 GΩ 19 µΩ/Ω + 4.5 µΩ 11 µΩ/Ω + 19 µΩ 9.5 µΩ/Ω + 100 µΩ 9.5 µΩ/Ω + 1 mΩ 9.5 µΩ/Ω + 10 mΩ 10 µΩ/Ω + 100 mΩ 12 µΩ/Ω + 1.5 Ω 12 µΩ/Ω + 1.5 Ω 21 µΩ/Ω + 110 Ω 0.13 % + 1.0 ΜΩ Fluke 8588A Resistance – Generate, Fixed Points 3 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 0.000 10 Ω 0.000 18 Ω 0.000 25 Ω 0.000 45 Ω 0.0010 Ω 0.0020 Ω 0.0089 Ω 0.018 Ω 0.088 Ω 0.18 Ω 1.2 Ω 2.6 Ω 21 Ω 42 Ω Fluke 5720A
10--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 10 of 22 Parameter/Equipment Range CMC2, 6 (±) Comments Resistance – Generate, Fixed Points3 (cont) 10 MΩ 19 MΩ 100 MΩ 0.001 Ω 0.01 Ω 0.1Ω 420 Ω 960 Ω 10 kΩ 0.11 µΩ 0.12 µΩ 1.2 µΩ Fluke 5720A L&N resistors Resistance – Generate3 (1 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 1.099 999) kΩ (1.1 to 10.999 99) kΩ (11 to 109.9999) kΩ 110k to 1.099 999 MΩ (1.1 to 3.299 99) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 54 µΩ/Ω + 1 mΩ 52 µΩ/Ω + 1.5 mΩ 35 µΩ/Ω + 1.4 mΩ 35 µΩ/Ω + 2.0 mΩ 35 µΩ/Ω + 2.0 mΩ 35 µΩ/Ω + 20 mΩ 36 µΩ/Ω + 200 mΩ 40µΩ/Ω + 2.0 Ω 74 µΩ/Ω + 30 Ω 0.016 % + 50 Ω 0.031 % + 2500 Ω 0.061 % + 3000 Ω 0.37 % + 100 kΩ 1.8 % + 500 kΩ Fluke 5520A Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage – Generate3 Up to 2.2 mV (2.2 to 22) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.025 % + 4.0 µV 0.010 % + 4.0 µV 0.010 % + 4.0 µV 0.020 % + 4.0 µV 0.05 % + 5.0 µV 0.10 % + 10 µV 0.15 % + 20 µV 0.25 % + 20 µV 0.024 % + 4.0 µV 0.009 % + 4.0 µV 0.008 % + 4.0 µV 0.020 % + 4.1 µV 0.050 % + 5.0 µV 0.11 % + 10 µV 0.14 % + 20 µV 0.27 % + 20 µV Fluke 5720A
to 1100 MΩ
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 11 of 22 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage – Generate3 (cont) (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (22 to 220) V (220 to 1100) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz 50 Hz to 1 kHz 0.024 % + 12 µV 0.009 % + 7.0 µV 0.008 % + 7.0 µV 0.020 % + 7.0 µV 0.047 % + 17 µV 0.090 % + 20 µV 0.14 % + 25 µV 0.27 % + 45 µV 0.025 % + 40 µV 0.093 % + 15 µV 0.0046 % + 8 µV 0.0075 % + 10 µV 0.012 % + 30 µV 0.043 % + 80 µV 0.10 % + 200 µV 0.18 % + 300 µV 0.025 % + 400 µV 0.0093 % + 150 µV 0.0046 % + 50 µV 0.007 % + 100 µV 0.009 % + 200 µV 0.027 % + 600 µV 0.10 % + 2.0 mV 0.16 % + 3.2 mV 0.025 % + 4.0 mV 1.0 % + 1.5 mV 0.0052 % + 600 µV 0.0085 % + 1.0 mV 0.015 % + 2.5 mV 0.092 % + 16 mV 0.44 % + 40 mV 0.81 % + 80 mV 0.030 % + 16 mV 0.0073 % + 3.5 mV Fluke 5720A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 12 of 22 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage – Generate3 (1 to 32.999) mV (33 to 329.999) mV (0.33 to 3.299 99) V (3.3 to 32.9999) V (33 to 329.999) V (330 to 1000) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.11 % + 6.0 µV 0.024 % + 6.0 µV 0.029 % + 6.0 µV 0.13 % + 6.0 µV 0.43 % + 12 µV 0.97 % + 50 µV 0.04 % + 8.0 µV 0.018 % + 8.0 µV 0.02 % + 8.0 µV 0.043 % + 8.0 µV 0.097 % + 32 µV 0.25 % + 70 µV 0.04 % + 50 µV 0.019 % + 60 µV 0.023 % + 60 µV 0.036 % + 50 µV 0.085 % + 130 µV 0.29 % + 600 µV 0.04 % + 650 µV 0.019 % + 600 µV 0.029 % + 600 µV 0.043 % + 600 µV 0.11 % + 1.6 mV 0.024 % + 2.0 mV 0.025 % + 6.0 mV 0.03 % + 6.0 mV 0.038 % + 6.0 mV 0.25 % + 50 mV 0.037 % + 10 mV 0.03 % + 10 mV 0.037 % + 10 mV Fluke 5520A AC High Voltage – Measure3 (1 to 10) kV 1 kV (10 to 75) kV 30 to 200 Hz 400 Hz 60 Hz 0.16 % 0.49 % 0.19 % Vitrek 4700 W/ HL100 probe
13--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 13 of 22 Parameter/Range Frequency CMC2, 6, 7 (±) Comments AC Voltage – Measure3 Up to 10 mV (>10 to 100) mV (>0.1 to 1) V (>1 to 10) V (>10 to 100) V 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz (>100 to 300) kHz (>0.3 to 1) MHz 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz (>100 to 300) kHz (>0.3 to 1) MHz (>1 to 2) MHz (>2 to 4) MHz (>4 to 8) MHz (>8 to 10) MHz 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz (>100 to 300) kHz (>0.3 to 1) MHz (>1 to 2) MHz (>2 to 4) MHz (>4 to 8) MHz (>8 to 10) MHz 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz (>100 to 300) kHz (>0.3 to 1) MHz (>1 to 2) MHz (>2 to 4) MHz (>4 to 8) MHz (>8 to 10) MHz 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz (>100 to 300) kHz (>0.3 to 1) MHz 350 µV/V + 1.1 µV 410 µV/V + 1.1 µV 420 µV/V + 1.1 µV 0.3 % + 1.1 µV 0.96 % + 4 µV 2.1 % + 4 µV 110 µV/V + 0.5 µV 140 µV/V + 0.5 µV 240 µV/V + 1 µV 0.055 % + 5 µV 0.22 % + 30 µV 1.1 % + 100 µV 1.6 % + 500 µV 4.1 % + 1 mV 8.5 % + 1 mV 16 % + 1 mV 82 µV/V + 5 µV 130 µV/V + 5 µV 230 µV/V + 10 µV 0.054 % + 50 µV 0.22 % + 300 µV 1 % + 1 mV 1.5 % + 5 mV 4 % + 10 mV 8.3 % + 10 mV 16 % + 10 mV 82 µV/V + 50 µV 130 µV/V + 50 µV 230 µV/V + 100 µV 0.054 % + 500 µV 0.22 % + 3 mV 1 % + 10 mV 1.5 % + 50 mV 4 % + 100 mV 8.3 % + 100 mV 16 % + 100 mV 95 µV/V + 500 µV 120 µV/V + 500 µV 250 µV/V + 1 mV 0.061 % + 5 mV 0.37 % + 50 mV 1.1 % + 500 mV Fluke 8588A
to 0.01 V
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 14 of 22 Parameter/Range Frequency CMC2, 6 (±) Comments AC Voltage – Measure3 (cont) (>100 to 1000) V 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz 410 µV/V + 25 mV 140 µV/V + 25 mV 290 µV/V + 25 mV 0.071 % + 100 mV Fluke 8588A AC Current – Generate3 (29 to 330) μA 330 μA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 3.3 A (2.2 to 11) A (11 to 110) A (110 to 550) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 40 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz 50 Hz 50 Hz 0.30 % + 0.15 μA 0.15 % + 0.15 μA 0.15 % + 0.25 μA 0.28 % + 0.15 μA 1.5 % + 0.15 μA 0.24 % + 0.30 μA 0.12 % + 0.30 μA 0.12 % + 0.30 μA 0.24 % + 0.30 μA 0.72 % + 0.30 μA 0.24 % + 3.0 μA 0.12 % + 3.0 μA 0.11 % + 30 μA 0.24 % + 30 nA 0.74 % + 30 μA 0.24 % + 30 μA 0.12 % + 30 μA 0.11 % + 30 μA 0.24 % + 30 μA 0.72 % + 30 μA 0.24 % + 300 μA 0.12 % + 300 μA 0.40 % + 2.0 mA 0.080 % + 2.0 mA 0.12 % + 2.0 mA 0.40 % + 2.0 mA 1.3 % + 1.9 mA 0.66 % + 1.1 A Fluke 5720A Fluke 5720A w/ 50 turn coil
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 15 of 22 Parameter/Range Frequency CMC2, 6 (±) Comments AC Current – Generate3 (cont) (20 to 150) A (151 to 1000) A (20 to 150) A (151 to 1000) A (45 to 65) Hz (45 to 65) Hz (65 to 440) Hz (65 to 440) Hz 1.4 A + 0.0035 A/A 0.68 A + 0.012 A/A 1.4 A + 0.0072 A/A 1.5 A + 0.011 A/A Fluke 5520A w/ 50 turn coil AC Current – Measure3 Up to 10 µA (>10 to 100) µA (>0.1 to 1) mA (>1 to 10) mA (>10 to 100) mA (>0.1 to 1) A (>1 to 10) A (>10 to 30) A 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz (>30 to 100) kHz 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz 10 Hz to 2 kHz (>2 to 10) kHz (>10 to 30) kHz 10 Hz to 2 kHz (>2 to 10) kHz 10 Hz to 2 kHz (>2 to 10) kHz 0.22 % + 2.5 nA 0.22 % + 2.5 nA 0.23 % + 2.5 nA 320 µA/A + 5 nA 550 µA/A + 5 nA 840 µA/A + 5 nA 0.41 % + 10 nA 300 µA/A + 50 nA 540 µA/A + 50 nA 830 µA/A + 50 nA 0.41 % + 100 nA 290 µA/A + 500 nA 530 µA/A + 500 nA 820 µA/A + 500 nA 0.41 % + 1 mA 290 µA/A + 5 µA 530 µA/A + 5 µA 950 µA/A + 5 µA 370 µA/A + 100 µA 690 µA/A + 100 µA 0.1 % + 100 µA 950 µA/A + 500 µA 950 µA/A + 500 µA 0.12 % + 12 mA 0.16 % + 12 mA Fluke 8588A
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 16 of 22 Parameter/Equipment Range CMC2, 6 (±) Comments Capacitance – Generate3 (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) μF (1.1 to 3.299 99) μF (3.3 to 10.9999) μF (11 to 32.9999) μF (33 to 109.9999) μF (110 to 329.999) μF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 0.88 % + 10 pF 0.67 % + 10 pF 0.62 % + 10 pF 0.35 % + 10 pF 0.31 % + 100 pF 0.32 % + 100 pF 0.32 % + 300 pF 0.32 % + 1.0 nF 0.31 % + 3.0 nF 0.32 % + 10 nF 0.49 % + 30 nF 0.56 % + 100 nF 0.56 % + 300 nF 0.57 % + 1.0 µF 0.56 % + 3.0 µF 0.56 % + 10 µF 0.91 % + 30 µF 1.3 % + 100 µF Fluke 5520A Electrical Calibration of Thermocouples & Thermocouple Indicating Systems3 – Type B Type C Type E Type J (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C 0.50 °C 0.35 °C 0.35 °C 0.34 °C 0.30 °C 0.28 °C 0.31 °C 0.55 °C 0.90 °C 0.50 °C 0.23 °C 0.22 °C 0.23 °C 0.27 °C 0.32 °C 0.23 °C 0.17 °C 0.20 °C 0.25 °C Fluke 5520A
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 17 of 22 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouples & Thermocouple Indicating Systems 3 – (cont) Type K Type L Type N Type R Type S Type T Type U (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 800) °C (800 to 900) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-200 to 0) °C (0 to 600) °C 0.37 °C 0.25 °C 0.23 °C 0.31 °C 0.42°C 0.40 °C 0.31 °C 0.24 °C 0.42 °C 0.28 °C 0.26 °C 0.25 °C 0.32 °C 0.60 °C 0.40 °C 0.37 °C 0.42 °C 0.48 °C 0.39 °C 0.40 °C 0.50 °C 0.65 °C 0.25 °C 0.20 °C 0.15 °C 0.56 °C 0.32 °C Fluke 5520A
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 18 of 22 Parameter/Equipment Range CMC2, 6, 7 (±) Comments Electrical Calibration of RTD Indicating System3 – Pt 385, 100 Ω Pt 3926, 100 Ω PtNi 385, 120 Ω Cu 427, 10 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-100 to 260) °C 0.059 °C 0.058 °C 0.060 °C 0.10 °C 0.12 °C 0.12 °C 0.27 °C 0.059 °C 0.058 °C 0.081 °C 0.1 °C 0.12 °C 0.14 °C 0.093 °C 0.093 °C 0.16 °C 0.35 °C Fluke 5520A Oscilloscopes3 – DC Voltage: 50 Ω 1 MΩ Leveled Sine Wave Characteristics Into 50 Ω Sine Wave Signal Amplitude – Generate Time Mark (50 Ω) Rise Time (0 to ± 6.6) V (0 to ± 130) V 50 kHz (reference) 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz 600 MHz to 1.1 GHz (2 to 5) ns 10 ns (20 to 50) ns 100 ns to 20 ms 50 ms to 5 s ≤300 ps 0.29 % + 40 μV 0.064 % + 40 μV 2.2 % + 300 µV 4.0 % + 300µV 4.3 % + 300 μV 4.3 % + 300 μV 7.9 % + 300 μV 0.000 29 % 0.000 29 % 0.000 29 % 0.000 29 % 25 + t*1000 uS/S (+ 0.0 ns / -120 ps) Fluke 5520A/SC1100 t = time in seconds
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 19 of 22 IV. Magnetic Quantities Parameter/Equipment Range CMC2, 7, 8 (±) Comments Magnetic Flux Density – Measuring Equipment3 (Gauss Meters) (-50 to 50) gauss 0.22 % Current shunt, multimeter V. Mechanical Parameter/Equipment Range CMC2, 4, 7, 8 (±) Comments Force – Measure, Tension & Compression3 Up to 500 lbf (50 to 500) lbf (501 to 1000) lbf (1001 to 5000) lbf 0.014 % + 0.058 lbf 0.0026 % + 3.5 lbf 0.040 % + 2.7 lbf 0.29 % + 0.000 69 lbf Class F weights force transducers / load cells Pressure – Measuring Equipment3 Absolute Gauge (80 to 120) kPa (11.6 to 17.4) psia Up to 115 psia Up to 1015 psia Up to 3015 psia Up to 10 000 psig Up to 20 000 psig Up to 40 000 psig (-1 to 1) in·H2O (-5 to 5) in·H2O (-30 to 30) in·H2O (-75 to 75) in·H2O (-14.5 to 30) psig (30 to 100) psig (100 to 300) psig (0.058 + 0.000 033p) kPa 0.0062 psia + 0.6R 0.0028 psia + 0.6R (0.0041 + 0.000 056p) psia + 0.6R (0.15 + 0.000 02p) psia + 0.6R 2.6 psig + 0.6R 12 psig + 0.6R 47 psig + 0.6R 0.001 in·H2O + 0.6R 0.0007 in·H2O + 0.6R 0.0054 in·H2O + 0.6R 0.019 in·H2O + 0.6R 0.027 % + 0.024 psig + 0.6R 0.046 % + 0.036 psig + 0.6R 0.038 % + 0.013 psig + 0.6R Multifunction calibrator Digital pressure modules Digital pressure gage Multifunction calibrator
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 20 of 22 Parameter/Equipment Range CMC2, 4, 8 (±) Comments Torque Transducers3 (20 to 200) ozf·in (0 to 50) lbf·in (50 to 250) lbf·in (250 to 1000) lbf ·in (0 to 250) lbf ·ft (250 to 2000) lbf ·ft (0.0074 % + 0.041) ozf·in (0.039 % + 0.0088) lbf·in (0.018 % + 0.019) lbf·in (0.032 % + 0.012) lbf ·in (0.1 % + 0.026) lbf·ft (0.055 % + 0.13) lbf ·ft Torque arms, weights Torque Devices3 (Wrenches, Screwdrivers, Pneumatic, Electronic, & Watches) (4 to 40) ozf·in (4 to 50) lbf·in (40 to 400) lbf·in (100 to 1000 lbf·in (25 to 250) lbf·ft (80 to 800) lbf·ft (400 to 4000) lbf·ft (0.23 % + 0.28) ozf·in (0.066 % + 0.29) lbf·in (0.4 % + 0.26) lbf·in (0.46 % + 0.73) lbf·in (0.42 % + 0.27) lbf·ft (0.53 % + 0.83) lbf·ft (0.017 % + 4.8) lbf·ft Torque transducers, display unit Vacuum – Measuring Equipment 3 (-30 to 0) in·Hg 0.018 % Primary vacuum standard Air Velocity – Measuring Equipment (500 to 8000) fpm (1.1 + 0.012V) fpm Comparison of standard probe w/ UUT using wind tunnel Scales & Balances3 Up to 200 g 100 g to 20 kg Up to 5000 lb 0.032 % + 0.0018 mg 0.054 % + 0.0051 mg 0.0094 % + 0.12 lb Weights, Class E1, Class F1, & Class F VI. Thermodynamics Parameter/Equipment Range CMC2, 7,8 (±) Comments Relative Humidity – Measure3 (Humidity Ovens, Chambers, & Cells) Up to 50 % RH (50 to 90) % RH 0.75 % RH 0.89 % RH Rotronic HygroPalm
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 21 of 22 Parameter/Equipment Range CMC2, 7, 8 (±) Comments Relative Humidity – Measuring Equipment (@ 25°C) Sensors & Humidity Meters (10 to 95) % RH 0.64 % RH Humidity chamber Temperature – Measure Uniformity Surveys (Ovens, Furnaces, Autoclaves, & Freezers) (-196 to 660) °C 0.0052 % + 0.024 °C SPRT w/ indicator Temperature – Measuring Equipment (Sensors & Thermometers) (-196 to 660) °C 0.0052 % + 0.024 °C SPRT w/ indicator Temperature – IR Measuring Equipment3 35 °C (>35 to 100) °C (>100 to 200) °C (>200 to 350) °C (>350 to 500) °C 0.74 °C 0.89 °C 1.2 °C 1.6 °C 2.3 °C Fluke 4181 ε = 0.95 λ = (8 to 14) µm VII. Time & Frequency Parameter/Equipment Range CMC2, 4, 7 (±) Comments Tachometers – Contact Up to 10 000 RPM 0.078 RPM + 0.6R GPS receiver w/ frequency counter Tachometers – Non-Contact3 Up to 199 999 RPM 0.0012 % Function generator Stop Watches/Time Measurements3 Up to 24 hours 0.022 s/day Stopwatch calibrator
22--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.03) 11/07/2025 Page 22 of 22 Parameter/Equipment Range CMC2, 7 (±) Comments Frequency – Measure 10 Hz to 20 MHz (20 to 350) MHz 0.000 45 Hz 0.042 Hz Frequency counter Frequency – Measuring Equipment3 Up to 30 MHz 10 MHz to 2.1 GHz 0.0058 Hz 0.013 Hz Keysight 33518B Fluke 6062A __________________________________________ 1 This laboratory offers commercial dimensional testing/calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) uncertainty is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC uncertainty due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches or millimeters. D is the numerical value of the nominal diameter of the device measured in inches or millimeters. V is the velocity of the reading. H is the Humidity of the reading. M is the mass of the reading in grams or pounds. T is the temperature of the measure in Celsius. P is pressure in psia. X represents current in Amperes. R is the resolution of the unit under test 5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 6 The measurands stated are generated using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMC uncertainties are expressed as either a specific value that covers the full range or as a percent/fraction of the reading plus a fixed floor specification. 7 In the statement of CMC, percentage (%) refers to percent of reading, unless otherwise noted. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 This scope meets A2LA’s P112 Flexible Scope Policy.
10 to 2100 MHz
23ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3130 Stanton Ct, N. Charleston, SC, 29418, US

32.85462, -79.97481

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.