MSI-Viking Gage
3130 Stanton Ct, 29418, N. Charleston, SC, United States
Visit website- Scope lines
- 23
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 23 scope lines.
A2LA certificate 1387.03 · 23 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | pH buffer standards; Conductivity standards; Brix solutions | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 2 of 22
II. Dimensional
Parameter/Equipment
Range CMC2, 4 (±) Comments
Angular Devices –
Measure5
Up to 90°
0.0044°
Vision system
Bolt Protrusion Gages
Up to 12 in
5.8 μin
Vision system
Bore Micrometers3 –
Point
Up to 12 in
(34 + 2.7D) μin + 0.6R
Master rings
Bore Gages (Dial/Digital)
(Bore Gage w/ Indicator)
Up to 4 in
(12 + 2.3D) µin + 0.6R
Gage blocks
Calipers3
Up to 80 in
(21 + 7.4L) µin + 0.6R
Long gage blocks,
gage blocks
Check Masters/Caliper
Checkers/Step Gages
Up to 24 in
Up to 1300 mm
(15 + 2.7L) µin
(1.4 + 0.0033L) µm
Electronic indicator,
gage blocks
CMM
Caliper Gage3 – Internal,
External
Up to 7.5 in
(8.9 + 3.9L) µin +
0.6R
Gage blocks
Chamfer Check Gages
Set Ring Effective
Diameter
Gage Probe Angle
48 µin + 0.6R
0.0044 °
Chamfer check master,
set ring
Vision system
Coating Thickness Gages
(1 to 669) mils
10 μin
Master foils,
foils/shims,
ULM
Crimping Tools3
Up to 1.0 in
Pull Test
0.0006 in
0.13 lbf
Pin gages
Force gage | to 90 ° |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 3 of 22
Parameter/Equipment
Range CMC2, 4 (±) Comments
Cylindrical Ring Gages3
Up to 2 in
(2 to 17) in
(6.2 + 2.6D) µin
(2.8 + 4.2D) µin
Universal length
machine, master
rings, gage blocks
Cylindrical Disc, Plug, &
Pin Gages
3
Up to 32 in
Up to 1 in
(3.5 + 2.8D) μin
(25 + 5.7L) µin
Universal length
machine, gage blocks
Micrometer
Depth Step Gages
Up to 12 in
(13 + 3.2L) µin
Electronic indicator
amplifier, gage blocks
Electronic Indicator
Amplifier
3
Up to 0.02 in
(6.6 + 140L) µin
Gage blocks
Height Gages3
Up to 48 in
(4.3 + 3.5L) µin + 0.6R
Gage blocks, long
gage blocks, surface
plate
Optical Flats
Up to 6 in
3.1 μin
Master optical flat
Sine Bars / Plates –
Length
Flatness
Parallelism
Up to 10 in
Up to 10 in
Up to 10 in
41 µin
28 µin
27 µin
LVDT
Glass Scales
Up to 12 in
(40 + 2.9L) µin
Vision system
Indicators/LVDTs3
Up to 4 in
Up to 3.93 in (100 mm)
(4.2 + 3.7L) µin + 0.6R
(14 + 3.3L) µin
Gage blocks
Indicator calibrator | to 2 in |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 4 of 22
Parameter/Equipment
Range CMC2, 4 (±) Comments
Length Standards3
Up to 32 in
Up to 1300 mm
(5.1 + 2.5L) µin
(1.4 + 0.0032L) µm
ULM, gage blocks
CMM
Levels3
Up to 12 in
Up to 18 in
45 µin + 0.6R
4 arc sec
Surface plate, sine
bar, gage blocks
Leveling plate,
amplifier
Micrometers3 – Groove
& Specialty (Outside/
Inside/Tubular/Indicating
& Snap)
Depth
Up to 60 in
Up to 12 in
(5.7 + 3.4L) µin + 0.6R
(4.3 + 3.3L) µin + 0.6R
Gage blocks
Gage locks
Indicator Calibrators3
(Mic Head Type)
Up to 4 in
(6.9 + 3L) µin + 0.6R
Gage blocks
Parallels
Up to 20 in
(15 + 1.7L) μin
Electronic gage
amplifier, surface
plate
Protractor –
Bevel
Digital
3
Up to 180°
Up to 90°
0.0044°
0.07° + 0.6R
Vision system
Sine plate, gage
blocks
Steel Rules3
Up to 3000 mm
Up to 12 in
Up to 72 in
(29 + 0.021L) µm
(37 + 1.2L) µin
(7.3 + 3.8L) in
Linear measurement
table
Vision system
Direct comparison,
gage blocks
Steel Tapes/Pi Tapes
Up to 30.5 m
(29 + 0.021L) µm
Linear measurement
table | to 30.5 m |
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 5 of 22
Parameter/Equipment
Range CMC2, 4 (±) Comments
Thickness & Feeler
Gages3
Up to 2 in (5.6 + 1.5L) µin
ULM
Thread Measuring
Wires3
(4 to 120) TPI
5.8 µin
ULM
Laser Micrometers3
Up to 2 in
(12 + 7.9D) µin
Master pin gages
Screw Thread Micrometer
Standards
Up to 6 in
(29 + 1.3L) μin
Vision system
Snap Gage3 –
Flatness of Anvils
Size
Up to 3 in
Up to 20 in
4.2 μin
(5.6 + 2.4L) µin + 0.6R
Optical flat
Gage blocks
Universal Measuring
Machines/Bench
Micrometers3
Up to 12 in
(4.1 + 2.3L) μin
Gage blocks
Radius Gages
Up to 4 in
(25 + 18L) µin
Vision system
Thread Rings8
Up to 4.75 in
170 µin
Set using master plug
gages Class W
NPT Tapered Thread
Rings –
Standoff
Ring Thickness
Up to 1.5 in
Up to 2.0 in
(15 + 0.013L) µin
(4.6 + 2.6L) µin
Electronic indicator,
master NPT plug
Universal length
machine (ULM) | to 2 in |
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 6 of 22
Parameter/Equipment
Range CMC2, 4 (±) Comments
Video Measurement
System3 –
X, Y Axis
Z Axis
Up to 12 in
Up to 6 in
(120 + 4.2L) μin
(9.7 + 1.9L) μin
Calibration grid
Gage blocks
Surface Finish
Testers3
(2 to 500) µin
5.3 µin
Master surface finish
patch
Surface Finish
Standards3
(2 to 500) µin
5.3 µin
Direct comparison to
master surface patch
Spheres & Balls
Up to 6 in
(5.6 + 1.8D) μin
ULM
Thread Plugs3 –
Major Diameter
Pitch Diameter
Step
Up to 8 in
(4 to 120) TPI
Up to 1 in
(12 + 1.3D) μin
(33 + 2.1D) μin
160 μin
ULM
ULM, thread
measuring wires
Gage blocks, uni-
micrometer
Ultrasonic Thickness
Gages3
Up to 4 inches
(2.4 + 5.1L) μin + 0.6R
Gage blocks
II. Dimensional Testing/Calibration5
Parameter/Equipment
Range CMC2, 8 (±) Comments
Surface Finish5 – Measure
(2 to 500) µin
5.3 µin
Master surface finish
patch | 2 to 500 µin |
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 7 of 22
Parameter/Equipment
Range CMC2, 4, 8 (±) Comments
Geometric Measurements5 –
1D, 2D, 3D
(X, Y, Z & Volumetric)
(Up to 1500) mm
(1.4 + 0.0038L) µm
CMM
2D Optical Inspection5 –
Measure
X-Y
Angle
Up to 315 mm
Up to 90°
5.8 μm
0.0044°
Vision system
Flatness5 – Measure
Up to 6 in
Up to 20 in
Up to 1400 mm
5.0 μin
26 μin
(1.4 + 0.0038L) μm
Optical flat
Electronic indicator
amplifier
CMM
Parallelism5– Measure
Up to 20 in
(20 + 1.5L) µin
Electronic gage
amplifier
Radius5 – Measure
Up to 12 in
(25 + 18L) µin
Vision system
Straightness5 – Measure
Up to 12 in
(20 + 1.1L) µin
Electronic indicator
amplifier
Angular Devices –
Measure
5
Up to 360°
0.0044°
Vision system
Attribute Gages
Up to 12 in
Up to 32 in,
External Measurement
Up to 12 in,
Internal Measurement
Up to 6 in
(73 + 5.9L) µin
(6.2 + 2.4L) µin
(15 + 2.6L) µin
300 µin
Vision system
Universal length
machine
Electronic indicator
amplifier, gage
blocks, rings, plugs,
hand tools | to 1500 mm |
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 8 of 22
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
DC Voltage – Measure3
100 mV
1 V
10V
100V
1000V
11 µV/V + 0.42 µV
3.3 µV/V + 0.38 µV
3.4 µV/V + 1.3 µV
4.8 µV/V + 38 µV
5 µV/V + 580 µV
Fluke 8588A
DC High Voltage –
Measure3
(1 to 9) kV
(10 to 90) kV
0.1 V + 0.000 52 V/V
7.7 V + 0.0014 V/V
High voltage meter
High voltage meter /
high voltage probe
DC Voltage – Generate3
Up to 220 mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
Up to 329.9999 mV
330 mV to 3.299 V
(3.3 to 32.9999) V
(30 to 329.9999) V
(100 to 1000) V
0.0009 % + 0.47 µV
0.0006 % + 0.9 µV
0.0004 % + 2.9 µV
0.0004 % + 4.1 µV
0.0006 % + 50 µV
0.0008 % + 250 µV
24 µV/V + 1.0 µV
14 µV/V + 2.0 µV
15 µV/V + 20 µV
22 µV/V + 150 µV
22 µV/V + 1.5 mV
Fluke 5720A
Fluke 5520A
DC Current – Measure3
10 µA
100 µA
1.0 mA
10 mA
100 mA
1.0 A
10 A
30 A
35 µA/A + 0.4 nA
12 µA/A + 0.4 nA
11 µA/A + 4.1 nA
15 µA/A + 41 nA
60 µA/A + 1 µA
130 µA/A + 100 µA
240 µA/A + 400 µA
550 µA/A + 4.4 mA
Fluke 8588A
High Current –
Measure3
DC: Up to 60 Hz
(1 to 15) A
(15 to 100) A
(100 to 300) A
(300 to 2500) A
0.024 % + 3.0 mA
0.023 % + 24 mA
0.011 % + 36 mA
(0.26 + 0.0061X) A
Current shunt
w/ 6.5 digit voltmeter | to 1000 V |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 9 of 22
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
DC Current – Generate3
Up to 220 µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
0.008 % + 6 nA
0.0072 % + 7 nA
0.0073 % + 40 nA
0.093 % + 0.7 nA
0.017 % + 12 nA
0.036 % + 0.48 mA
Fluke 5720A w/
5725A
DC Current – Generate3
(1 to 329.999) µA
(0.33 to 3.299 99) mA
(3.3 to 32.9999) mA
(33 to 329.999) mA
(0.33 to 1.099 99) A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(10 to 16.499) A
(16.5 to 149.999) A
(150 to 950) A
0.018 % + 20 nA
0.012 % + 50 nA
0.013 % + 250 nA
0.015 % + 3.0 µA
0.025 % + 40 µA
0.046 % + 40 µA
0.06 % + 500 µA
0.12 % + 750 µA
0.67 A
(0.67 + 0.0069X) A
(1.3 + 0.0022X) A
Fluke 5520A
Fluke 5520A w/
Fluke 5500A coil
Resistance – Measure3
1.9 Ω
19 Ω
190 Ω
1.9 kΩ
19 kΩ
190 kΩ
1.9 MΩ
19 MΩ
100 MΩ
1 GΩ
19 µΩ/Ω + 4.5 µΩ
11 µΩ/Ω + 19 µΩ
9.5 µΩ/Ω + 100 µΩ
9.5 µΩ/Ω + 1 mΩ
9.5 µΩ/Ω + 10 mΩ
10 µΩ/Ω + 100 mΩ
12 µΩ/Ω + 1.5 Ω
12 µΩ/Ω + 1.5 Ω
21 µΩ/Ω + 110 Ω
0.13 % + 1.0 ΜΩ
Fluke 8588A
Resistance – Generate,
Fixed Points
3
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
0.000 10 Ω
0.000 18 Ω
0.000 25 Ω
0.000 45 Ω
0.0010 Ω
0.0020 Ω
0.0089 Ω
0.018 Ω
0.088 Ω
0.18 Ω
1.2 Ω
2.6 Ω
21 Ω
42 Ω
Fluke 5720A | ||
| 10 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 10 of 22
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Resistance – Generate,
Fixed Points3 (cont)
10 MΩ
19 MΩ
100 MΩ
0.001 Ω
0.01 Ω
0.1Ω
420 Ω
960 Ω
10 kΩ
0.11 µΩ
0.12 µΩ
1.2 µΩ
Fluke 5720A
L&N resistors
Resistance – Generate3
(1 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(0.33 to 1.099 999) kΩ
(1.1 to 10.999 99) kΩ
(11 to 109.9999) kΩ
110k to 1.099 999 MΩ
(1.1 to 3.299 99) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
54 µΩ/Ω + 1 mΩ
52 µΩ/Ω + 1.5 mΩ
35 µΩ/Ω + 1.4 mΩ
35 µΩ/Ω + 2.0 mΩ
35 µΩ/Ω + 2.0 mΩ
35 µΩ/Ω + 20 mΩ
36 µΩ/Ω + 200 mΩ
40µΩ/Ω + 2.0 Ω
74 µΩ/Ω + 30 Ω
0.016 % + 50 Ω
0.031 % + 2500 Ω
0.061 % + 3000 Ω
0.37 % + 100 kΩ
1.8 % + 500 kΩ
Fluke 5520A
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Generate3
Up to 2.2 mV
(2.2 to 22) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.025 % + 4.0 µV
0.010 % + 4.0 µV
0.010 % + 4.0 µV
0.020 % + 4.0 µV
0.05 % + 5.0 µV
0.10 % + 10 µV
0.15 % + 20 µV
0.25 % + 20 µV
0.024 % + 4.0 µV
0.009 % + 4.0 µV
0.008 % + 4.0 µV
0.020 % + 4.1 µV
0.050 % + 5.0 µV
0.11 % + 10 µV
0.14 % + 20 µV
0.27 % + 20 µV
Fluke 5720A | to 1100 MΩ |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 11 of 22
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Generate3
(cont)
(22 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) Hz
50 Hz to 1 kHz
0.024 % + 12 µV
0.009 % + 7.0 µV
0.008 % + 7.0 µV
0.020 % + 7.0 µV
0.047 % + 17 µV
0.090 % + 20 µV
0.14 % + 25 µV
0.27 % + 45 µV
0.025 % + 40 µV
0.093 % + 15 µV
0.0046 % + 8 µV
0.0075 % + 10 µV
0.012 % + 30 µV
0.043 % + 80 µV
0.10 % + 200 µV
0.18 % + 300 µV
0.025 % + 400 µV
0.0093 % + 150 µV
0.0046 % + 50 µV
0.007 % + 100 µV
0.009 % + 200 µV
0.027 % + 600 µV
0.10 % + 2.0 mV
0.16 % + 3.2 mV
0.025 % + 4.0 mV
1.0 % + 1.5 mV
0.0052 % + 600 µV
0.0085 % + 1.0 mV
0.015 % + 2.5 mV
0.092 % + 16 mV
0.44 % + 40 mV
0.81 % + 80 mV
0.030 % + 16 mV
0.0073 % + 3.5 mV
Fluke 5720A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 12 of 22
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Voltage – Generate3
(1 to 32.999) mV
(33 to 329.999) mV
(0.33 to 3.299 99) V
(3.3 to 32.9999) V
(33 to 329.999) V
(330 to 1000) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.11 % + 6.0 µV
0.024 % + 6.0 µV
0.029 % + 6.0 µV
0.13 % + 6.0 µV
0.43 % + 12 µV
0.97 % + 50 µV
0.04 % + 8.0 µV
0.018 % + 8.0 µV
0.02 % + 8.0 µV
0.043 % + 8.0 µV
0.097 % + 32 µV
0.25 % + 70 µV
0.04 % + 50 µV
0.019 % + 60 µV
0.023 % + 60 µV
0.036 % + 50 µV
0.085 % + 130 µV
0.29 % + 600 µV
0.04 % + 650 µV
0.019 % + 600 µV
0.029 % + 600 µV
0.043 % + 600 µV
0.11 % + 1.6 mV
0.024 % + 2.0 mV
0.025 % + 6.0 mV
0.03 % + 6.0 mV
0.038 % + 6.0 mV
0.25 % + 50 mV
0.037 % + 10 mV
0.03 % + 10 mV
0.037 % + 10 mV
Fluke 5520A
AC High Voltage –
Measure3
(1 to 10) kV
1 kV
(10 to 75) kV
30 to 200 Hz
400 Hz
60 Hz
0.16 %
0.49 %
0.19 %
Vitrek 4700
W/ HL100 probe | ||
| 13 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 13 of 22
Parameter/Range
Frequency
CMC2, 6, 7 (±)
Comments
AC Voltage – Measure3
Up to 10 mV
(>10 to 100) mV
(>0.1 to 1) V
(>1 to 10) V
(>10 to 100) V
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
(>100 to 300) kHz
(>0.3 to 1) MHz
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
(>100 to 300) kHz
(>0.3 to 1) MHz
(>1 to 2) MHz
(>2 to 4) MHz
(>4 to 8) MHz
(>8 to 10) MHz
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
(>100 to 300) kHz
(>0.3 to 1) MHz
(>1 to 2) MHz
(>2 to 4) MHz
(>4 to 8) MHz
(>8 to 10) MHz
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
(>100 to 300) kHz
(>0.3 to 1) MHz
(>1 to 2) MHz
(>2 to 4) MHz
(>4 to 8) MHz
(>8 to 10) MHz
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
(>100 to 300) kHz
(>0.3 to 1) MHz
350 µV/V + 1.1 µV
410 µV/V + 1.1 µV
420 µV/V + 1.1 µV
0.3 % + 1.1 µV
0.96 % + 4 µV
2.1 % + 4 µV
110 µV/V + 0.5 µV
140 µV/V + 0.5 µV
240 µV/V + 1 µV
0.055 % + 5 µV
0.22 % + 30 µV
1.1 % + 100 µV
1.6 % + 500 µV
4.1 % + 1 mV
8.5 % + 1 mV
16 % + 1 mV
82 µV/V + 5 µV
130 µV/V + 5 µV
230 µV/V + 10 µV
0.054 % + 50 µV
0.22 % + 300 µV
1 % + 1 mV
1.5 % + 5 mV
4 % + 10 mV
8.3 % + 10 mV
16 % + 10 mV
82 µV/V + 50 µV
130 µV/V + 50 µV
230 µV/V + 100 µV
0.054 % + 500 µV
0.22 % + 3 mV
1 % + 10 mV
1.5 % + 50 mV
4 % + 100 mV
8.3 % + 100 mV
16 % + 100 mV
95 µV/V + 500 µV
120 µV/V + 500 µV
250 µV/V + 1 mV
0.061 % + 5 mV
0.37 % + 50 mV
1.1 % + 500 mV
Fluke 8588A | to 0.01 V |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 14 of 22
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Measure3
(cont)
(>100 to 1000) V
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
410 µV/V + 25 mV
140 µV/V + 25 mV
290 µV/V + 25 mV
0.071 % + 100 mV
Fluke 8588A
AC Current – Generate3
(29 to 330) μA
330 μA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 3.3 A
(2.2 to 11) A
(11 to 110) A
(110 to 550) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
50 Hz
50 Hz
0.30 % + 0.15 μA
0.15 % + 0.15 μA
0.15 % + 0.25 μA
0.28 % + 0.15 μA
1.5 % + 0.15 μA
0.24 % + 0.30 μA
0.12 % + 0.30 μA
0.12 % + 0.30 μA
0.24 % + 0.30 μA
0.72 % + 0.30 μA
0.24 % + 3.0 μA
0.12 % + 3.0 μA
0.11 % + 30 μA
0.24 % + 30 nA
0.74 % + 30 μA
0.24 % + 30 μA
0.12 % + 30 μA
0.11 % + 30 μA
0.24 % + 30 μA
0.72 % + 30 μA
0.24 % + 300 μA
0.12 % + 300 μA
0.40 % + 2.0 mA
0.080 % + 2.0 mA
0.12 % + 2.0 mA
0.40 % + 2.0 mA
1.3 % + 1.9 mA
0.66 % + 1.1 A
Fluke 5720A
Fluke 5720A w/ 50
turn coil | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 15 of 22
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Current – Generate3
(cont)
(20 to 150) A
(151 to 1000) A
(20 to 150) A
(151 to 1000) A
(45 to 65) Hz
(45 to 65) Hz
(65 to 440) Hz
(65 to 440) Hz
1.4 A + 0.0035 A/A
0.68 A + 0.012 A/A
1.4 A + 0.0072 A/A
1.5 A + 0.011 A/A
Fluke 5520A w/ 50
turn coil
AC Current – Measure3
Up to 10 µA
(>10 to 100) µA
(>0.1 to 1) mA
(>1 to 10) mA
(>10 to 100) mA
(>0.1 to 1) A
(>1 to 10) A
(>10 to 30) A
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
(>30 to 100) kHz
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
10 Hz to 2 kHz
(>2 to 10) kHz
(>10 to 30) kHz
10 Hz to 2 kHz
(>2 to 10) kHz
10 Hz to 2 kHz
(>2 to 10) kHz
0.22 % + 2.5 nA
0.22 % + 2.5 nA
0.23 % + 2.5 nA
320 µA/A + 5 nA
550 µA/A + 5 nA
840 µA/A + 5 nA
0.41 % + 10 nA
300 µA/A + 50 nA
540 µA/A + 50 nA
830 µA/A + 50 nA
0.41 % + 100 nA
290 µA/A + 500 nA
530 µA/A + 500 nA
820 µA/A + 500 nA
0.41 % + 1 mA
290 µA/A + 5 µA
530 µA/A + 5 µA
950 µA/A + 5 µA
370 µA/A + 100 µA
690 µA/A + 100 µA
0.1 % + 100 µA
950 µA/A + 500 µA
950 µA/A + 500 µA
0.12 % + 12 mA
0.16 % + 12 mA
Fluke 8588A | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 16 of 22
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Capacitance – Generate3
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) μF
(1.1 to 3.299 99) μF
(3.3 to 10.9999) μF
(11 to 32.9999) μF
(33 to 109.9999) μF
(110 to 329.999) μF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
0.88 % + 10 pF
0.67 % + 10 pF
0.62 % + 10 pF
0.35 % + 10 pF
0.31 % + 100 pF
0.32 % + 100 pF
0.32 % + 300 pF
0.32 % + 1.0 nF
0.31 % + 3.0 nF
0.32 % + 10 nF
0.49 % + 30 nF
0.56 % + 100 nF
0.56 % + 300 nF
0.57 % + 1.0 µF
0.56 % + 3.0 µF
0.56 % + 10 µF
0.91 % + 30 µF
1.3 % + 100 µF
Fluke 5520A
Electrical Calibration of
Thermocouples &
Thermocouple Indicating
Systems3 –
Type B
Type C
Type E
Type J
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(0 to 150) °C
(150 to 650) °C
(650 to 1000) °C
(1000 to 1800) °C
(1800 to 2316) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
0.50 °C
0.35 °C
0.35 °C
0.34 °C
0.30 °C
0.28 °C
0.31 °C
0.55 °C
0.90 °C
0.50 °C
0.23 °C
0.22 °C
0.23 °C
0.27 °C
0.32 °C
0.23 °C
0.17 °C
0.20 °C
0.25 °C
Fluke 5520A | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 17 of 22
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouples &
Thermocouple Indicating
Systems
3 – (cont)
Type K
Type L
Type N
Type R
Type S
Type T
Type U
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to 800) °C
(800 to 900) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
(-200 to 0) °C
(0 to 600) °C
0.37 °C
0.25 °C
0.23 °C
0.31 °C
0.42°C
0.40 °C
0.31 °C
0.24 °C
0.42 °C
0.28 °C
0.26 °C
0.25 °C
0.32 °C
0.60 °C
0.40 °C
0.37 °C
0.42 °C
0.48 °C
0.39 °C
0.40 °C
0.50 °C
0.65 °C
0.25 °C
0.20 °C
0.15 °C
0.56 °C
0.32 °C
Fluke 5520A | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 18 of 22
Parameter/Equipment
Range
CMC2, 6, 7 (±)
Comments
Electrical Calibration of
RTD Indicating System3 –
Pt 385, 100 Ω
Pt 3926, 100 Ω
PtNi 385, 120 Ω
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.059 °C
0.058 °C
0.060 °C
0.10 °C
0.12 °C
0.12 °C
0.27 °C
0.059 °C
0.058 °C
0.081 °C
0.1 °C
0.12 °C
0.14 °C
0.093 °C
0.093 °C
0.16 °C
0.35 °C
Fluke 5520A
Oscilloscopes3 –
DC Voltage:
50 Ω
1 MΩ
Leveled Sine Wave
Characteristics Into
50 Ω
Sine Wave Signal
Amplitude – Generate
Time Mark (50 Ω)
Rise Time
(0 to ± 6.6) V
(0 to ± 130) V
50 kHz (reference)
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
600 MHz to 1.1 GHz
(2 to 5) ns
10 ns
(20 to 50) ns
100 ns to 20 ms
50 ms to 5 s
≤300 ps
0.29 % + 40 μV
0.064 % + 40 μV
2.2 % + 300 µV
4.0 % + 300µV
4.3 % + 300 μV
4.3 % + 300 μV
7.9 % + 300 μV
0.000 29 %
0.000 29 %
0.000 29 %
0.000 29 %
25 + t*1000 uS/S
(+ 0.0 ns / -120 ps)
Fluke
5520A/SC1100
t = time in seconds | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 19 of 22
IV. Magnetic Quantities
Parameter/Equipment
Range
CMC2, 7, 8 (±)
Comments
Magnetic Flux Density
– Measuring
Equipment3 (Gauss
Meters)
(-50 to 50) gauss
0.22 %
Current shunt,
multimeter
V. Mechanical
Parameter/Equipment
Range
CMC2, 4, 7, 8 (±)
Comments
Force – Measure,
Tension &
Compression3
Up to 500 lbf
(50 to 500) lbf
(501 to 1000) lbf
(1001 to 5000) lbf
0.014 % + 0.058 lbf
0.0026 % + 3.5 lbf
0.040 % + 2.7 lbf
0.29 % + 0.000 69 lbf
Class F weights
force
transducers /
load cells
Pressure – Measuring
Equipment3
Absolute
Gauge
(80 to 120) kPa
(11.6 to 17.4) psia
Up to 115 psia
Up to 1015 psia
Up to 3015 psia
Up to 10 000 psig
Up to 20 000 psig
Up to 40 000 psig
(-1 to 1) in·H2O
(-5 to 5) in·H2O
(-30 to 30) in·H2O
(-75 to 75) in·H2O
(-14.5 to 30) psig
(30 to 100) psig
(100 to 300) psig
(0.058 + 0.000 033p) kPa
0.0062 psia + 0.6R
0.0028 psia + 0.6R
(0.0041 + 0.000 056p) psia + 0.6R
(0.15 + 0.000 02p) psia + 0.6R
2.6 psig + 0.6R
12 psig + 0.6R
47 psig + 0.6R
0.001 in·H2O + 0.6R
0.0007 in·H2O + 0.6R
0.0054 in·H2O + 0.6R
0.019 in·H2O + 0.6R
0.027 % + 0.024 psig + 0.6R
0.046 % + 0.036 psig + 0.6R
0.038 % + 0.013 psig + 0.6R
Multifunction
calibrator
Digital pressure
modules
Digital pressure
gage
Multifunction
calibrator | ||
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 20 of 22
Parameter/Equipment
Range
CMC2, 4, 8 (±)
Comments
Torque Transducers3
(20 to 200) ozf·in
(0 to 50) lbf·in
(50 to 250) lbf·in
(250 to 1000) lbf ·in
(0 to 250) lbf ·ft
(250 to 2000) lbf ·ft
(0.0074 % + 0.041) ozf·in
(0.039 % + 0.0088) lbf·in
(0.018 % + 0.019) lbf·in
(0.032 % + 0.012) lbf ·in
(0.1 % + 0.026) lbf·ft
(0.055 % + 0.13) lbf ·ft
Torque arms, weights
Torque Devices3
(Wrenches,
Screwdrivers,
Pneumatic, Electronic,
& Watches)
(4 to 40) ozf·in
(4 to 50) lbf·in
(40 to 400) lbf·in
(100 to 1000 lbf·in
(25 to 250) lbf·ft
(80 to 800) lbf·ft
(400 to 4000) lbf·ft
(0.23 % + 0.28) ozf·in
(0.066 % + 0.29) lbf·in
(0.4 % + 0.26) lbf·in
(0.46 % + 0.73) lbf·in
(0.42 % + 0.27) lbf·ft
(0.53 % + 0.83) lbf·ft
(0.017 % + 4.8) lbf·ft
Torque transducers,
display unit
Vacuum – Measuring
Equipment
3
(-30 to 0) in·Hg
0.018 %
Primary vacuum
standard
Air Velocity –
Measuring Equipment
(500 to 8000) fpm
(1.1 + 0.012V) fpm
Comparison of
standard probe w/
UUT using wind
tunnel
Scales & Balances3
Up to 200 g
100 g to 20 kg
Up to 5000 lb
0.032 % + 0.0018 mg
0.054 % + 0.0051 mg
0.0094 % + 0.12 lb
Weights, Class E1,
Class F1, & Class F
VI. Thermodynamics
Parameter/Equipment
Range
CMC2, 7,8 (±)
Comments
Relative Humidity –
Measure3
(Humidity Ovens,
Chambers, & Cells)
Up to 50 % RH
(50 to 90) % RH
0.75 % RH
0.89 % RH
Rotronic HygroPalm | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 21 of 22
Parameter/Equipment
Range
CMC2, 7, 8 (±)
Comments
Relative Humidity –
Measuring Equipment
(@ 25°C)
Sensors & Humidity
Meters
(10 to 95) % RH
0.64 % RH
Humidity chamber
Temperature – Measure
Uniformity Surveys
(Ovens, Furnaces,
Autoclaves, &
Freezers)
(-196 to 660) °C
0.0052 % + 0.024 °C
SPRT w/ indicator
Temperature –
Measuring Equipment
(Sensors &
Thermometers)
(-196 to 660) °C
0.0052 % + 0.024 °C
SPRT w/ indicator
Temperature – IR
Measuring Equipment3
35 °C
(>35 to 100) °C
(>100 to 200) °C
(>200 to 350) °C
(>350 to 500) °C
0.74 °C
0.89 °C
1.2 °C
1.6 °C
2.3 °C
Fluke 4181
ε = 0.95
λ = (8 to 14) µm
VII. Time & Frequency
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Tachometers – Contact
Up to 10 000 RPM
0.078 RPM + 0.6R
GPS receiver w/
frequency counter
Tachometers –
Non-Contact3
Up to 199 999 RPM
0.0012 %
Function generator
Stop Watches/Time
Measurements3
Up to 24 hours
0.022 s/day
Stopwatch calibrator | ||
| 22 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1387.03) 11/07/2025 Page 22 of 22
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Frequency – Measure
10 Hz to 20 MHz
(20 to 350) MHz
0.000 45 Hz
0.042 Hz
Frequency counter
Frequency – Measuring
Equipment3
Up to 30 MHz
10 MHz to 2.1 GHz
0.0058 Hz
0.013 Hz
Keysight 33518B
Fluke 6062A
__________________________________________
1 This laboratory offers commercial dimensional testing/calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) uncertainty is the smallest uncertainty of
measurement that a laboratory can achieve within its scope of accreditation when performing more or
less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment.
CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence,
usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration
performed by the laboratory may be greater than the CMC uncertainty due to the behavior of the
customer’s device and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches
or millimeters. D is the numerical value of the nominal diameter of the device measured in inches or
millimeters. V is the velocity of the reading. H is the Humidity of the reading. M is the mass of the reading
in grams or pounds. T is the temperature of the measure in Celsius. P is pressure in psia. X represents
current in Amperes. R is the resolution of the unit under test
5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration.
6 The measurands stated are generated using the indicated instrument (see Comments). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges indicated.
CMC uncertainties are expressed as either a specific value that covers the full range or as a
percent/fraction of the reading plus a fixed floor specification.
7 In the statement of CMC, percentage (%) refers to percent of reading, unless otherwise noted.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
9 This scope meets A2LA’s P112 Flexible Scope Policy. | 10 to 2100 MHz |
| 23 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- G.T. Michelli Co., LLC - SAVANNAHSavannah, GA · ~136 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Roberts CalibrationPembroke, GA · ~174 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Co., LLC - AUGUSTAAugusta, GA · ~198 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Aalberts IPSAPageland, SC · ~214 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Sapphire Technical Solutions, L.L.C.Pineville, NC · ~262 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.