G.T. Michelli Co., LLC - SAVANNAH

218 Bourne Blvd, Suite G, 31408, Savannah, GA, United States

Visit website
A2LA 3601.09ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
7
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

A2LA certificate 3601.09 · 7 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 1 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No 3601.09) 04/14/2025 Page 2 of 6 II. Electrical DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Generate3 (0 to 329.9999) mV (0 to 3.299 999) V (0 to 32.999 99) V (30 to 329.9999) V (100 to 1020) V 51 µV/V + 2.3 µV 38 µV/V + 3.9 µV 38 µV/V + 39 µV 44 µV/V + 390 µV 45 µV/V + 1200 µV Fluke 5500A DC Current – Generate3 Up to 330 µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 2.2) A (2.2 to 11) A 140 µA/A + 0.02 µA 110 µA/A + 0.04 µA 82 µA/A + 0.19 µA 100 µA/A + 1.9 µA 300 µA/A + 34 µA 870 µA/A + 580 µA Fluke 5500A DC Current -Generate (Non-toroidal) (10 to 20) A (21 to 110) A (111 to 550) A 1.0 % + 2 mA 0.50 % + 15 mA 0.50 % + 50 mA Fluke 5500A w/ Transmille Coil DC Current – Measure3 (1 to 4) mA (4 to 33) mA (33 to 330) mA (0.33 to 2) A 130 µA/A + 0.05 µA 100 µA/A + 0.25 µA 100 µA/A + 3.3 µA 300 µA/A + 44 µA Keysight 34401A Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 Up to 33 mV (33 to 330) mV (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.12 % + 0.02 mV 0.078 % + 0.02 mV 0.12 % + 0.02 mV 0.16 % + 0.02 mV 0.31 % + 0.03 mV 0.84 % + 0.05 mV 0.048 % + 0.02 mV 0.024 % + 0.02 mV 0.055 % + 0.02 mV 0.080 % + 0.02mV 0.18 % + 0.13 mV 0.41 % + 0.26 mV Fluke 5500A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No 3601.09) 04/14/2025 Page 3 of 6 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (cont) (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1000) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.045 % + 0.000 047 V 0.024 % + 0.000 047 V 0.055 % + 0.000 047 V 0.078 % + 0.000 047 V 0.19 % + 0.000 16 V 0.41 % + 0.000 70 V 0.045 % + 0.000 62 V 0.027 % + 0.000 47 V 0.055 % + 0.000 47 V 0.078 % + 0.000 47 V 0.18 % + 0.0016 V 0.039 % + 0.0023 V 0.061 % + 0.0070 V 0.071 % + 0.0070 V 0.10 % + 0.0070 V 0.19 % + 0.062 V 0.039 % + 0.016 V 0.062 % + 0.016 V 0.070 % + 0.016 V Fluke 5500A AC Current – Generate3 (0.03 to 0.33) mA (0.33 to 3.3) mA (3.3 to 33) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.4 % + 0.03 µA 0.15 % + 0.03 µA 0.06 % + 0.03 µA 0.06 % + 0.03 µA 0.4 % + 0.3 µA 0.15 % + 0.2 µA 0.06 % + 0.2 µA 0.03 % + 0.2 µA 0.06 % + 0.2 µA 0.4 % + 0.3 µA 0.15 % + 0.3 µA 0.06 % + 0.3 µA 0.03 % + 0.2 µA 0.06 % + 0.2 µA Fluke 5500A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No 3601.09) 04/14/2025 Page 4 of 6 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (cont) (33 to 330) mA (0.33 to 2.2) A (2.2 to 11) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz 0.4 % + 3 µA 0.15 % + 3 µA 0.06 % + 3 µA 0.03 % + 2 µA 0.06 % + 2 µA 0.4 % + 0.2 mA 0.16 % + 0.2 mA 0.08 % + 0.2 mA 0.4 % + 0.2 mA 0.16 % + 0.2 mA 0.08 % + 0.2 mA Fluke 5500A Parameter/Equipment Range CMC2, 4 (±) Comments Resistance – Generate3 Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ 0.017 % + 0.000 78 Ω 0.014 % + 0.0012 Ω 0.0076 % + 0.0011 Ω 0.0075 % + 0.0016 Ω 0.0073 % + 0.000 001 6 kΩ 0.0071 % + 0.000 016 kΩ 0.0070 % + 0.000 016 kΩ 0.0071 % + 0.000 16 kΩ 0.0088 % + 0.000 16 kΩ 0.0095 % + 0.0016 kΩ 0.012 % + 0.000 001 6 MΩ 0.014 % + 0.000 023 MΩ 0.057 % + 0.000 039 MΩ 0.12 % + 0.0019 MΩ 0.53 % + 0.0023 MΩ 1.1 % + 0.078 MΩ Fluke 5500A Resistance – Measure3 Up to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 33) MΩ (33 to 100) MΩ 90 µΩ/Ω + 15 mΩ 90 µΩ/Ω + 60 mΩ 90 µΩ/Ω + 6Ω 110 µΩ/Ω + 6Ω 120 µΩ/Ω + 6Ω 150 µΩ/Ω + 55Ω 600 µΩ/Ω + 550Ω 1 mΩ/Ω + 550Ω Keysight 34401A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No 3601.09) 04/14/2025 Page 5 of 6 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators3 – Generate & Measure Type J Type K Type T (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.28 °C 0.19 °C 0.17 °C 0.22 °C 0.24 °C 0.33 °C 0.20 °C 0.21 °C 0.25 °C 0.37 °C 0.52 °C 0.24 °C 0.18 °C 0.20 °C Fluke 5500A III. Mechanical Parameter/Equipment Range CMC2 (±) Comments Pressure – Measuring Equipment (> to 500) psig (> 500 to 5000) psig (> 5000 to 10 000) psig 0.66 psi 6.5 psi 13 psi Crystal XP2i 500 psi Crystal XP2i 10,000 psi Torque – Measuring Equipment3 (5 to 150) lbf·in (25 to 250) lbf·ft (60 to 600) lbf·ft 0.85 % of Reading 0.69 % of Reading 0.98 % of Reading Snap-On torque transducer CDI torque transducer Snap-On torque transducer Speed-Measuring Equipment (2 to 99,999) RPM 1.7 RPM Tachometer (centrifuge speed)
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No 3601.09) 04/14/2025 Page 6 of 6 IV. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Temperature – Measure & Measuring Equipment3 (0 to 150) °C 0.1 °C Thermoworks reference thermometer w/ cold or heat source V. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments RPM3 (1 to 999) RPM (1000 to 12000) RPM 1.3 RPM 3.0 RPM Ametek DigiStrobe Timers & Stopwatches (> to 83,000) Seconds 810 ms Control Company stopwatch __________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
0 to 150 °C
7ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

218 Bourne Blvd, Suite G, Savannah, GA, 31408, US

32.07901, -81.09213

Open in Maps