G.T. Michelli Co., LLC - SAVANNAH
218 Bourne Blvd, Suite G, 31408, Savannah, GA, United States
Visit website- Scope lines
- 7
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 7 scope lines.
A2LA certificate 3601.09 · 7 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 1 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No 3601.09) 04/14/2025 Page 2 of 6
II. Electrical DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage –
Generate3
(0 to 329.9999) mV
(0 to 3.299 999) V
(0 to 32.999 99) V
(30 to 329.9999) V
(100 to 1020) V
51 µV/V + 2.3 µV
38 µV/V + 3.9 µV
38 µV/V + 39 µV
44 µV/V + 390 µV
45 µV/V + 1200 µV
Fluke 5500A
DC Current – Generate3
Up to 330 µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 2.2) A
(2.2 to 11) A
140 µA/A + 0.02 µA
110 µA/A + 0.04 µA
82 µA/A + 0.19 µA
100 µA/A + 1.9 µA
300 µA/A + 34 µA
870 µA/A + 580 µA
Fluke 5500A
DC Current -Generate
(Non-toroidal)
(10 to 20) A
(21 to 110) A
(111 to 550) A
1.0 % + 2 mA
0.50 % + 15 mA
0.50 % + 50 mA
Fluke 5500A w/
Transmille Coil
DC Current – Measure3
(1 to 4) mA
(4 to 33) mA
(33 to 330) mA
(0.33 to 2) A
130 µA/A + 0.05 µA
100 µA/A + 0.25 µA
100 µA/A + 3.3 µA
300 µA/A + 44 µA
Keysight 34401A
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
Up to 33 mV
(33 to 330) mV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
0.12 % + 0.02 mV
0.078 % + 0.02 mV
0.12 % + 0.02 mV
0.16 % + 0.02 mV
0.31 % + 0.03 mV
0.84 % + 0.05 mV
0.048 % + 0.02 mV
0.024 % + 0.02 mV
0.055 % + 0.02 mV
0.080 % + 0.02mV
0.18 % + 0.13 mV
0.41 % + 0.26 mV
Fluke 5500A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No 3601.09) 04/14/2025 Page 3 of 6
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
(cont)
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.045 % + 0.000 047 V
0.024 % + 0.000 047 V
0.055 % + 0.000 047 V
0.078 % + 0.000 047 V
0.19 % + 0.000 16 V
0.41 % + 0.000 70 V
0.045 % + 0.000 62 V
0.027 % + 0.000 47 V
0.055 % + 0.000 47 V
0.078 % + 0.000 47 V
0.18 % + 0.0016 V
0.039 % + 0.0023 V
0.061 % + 0.0070 V
0.071 % + 0.0070 V
0.10 % + 0.0070 V
0.19 % + 0.062 V
0.039 % + 0.016 V
0.062 % + 0.016 V
0.070 % + 0.016 V
Fluke 5500A
AC Current – Generate3
(0.03 to 0.33) mA
(0.33 to 3.3) mA
(3.3 to 33) mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.4 % + 0.03 µA
0.15 % + 0.03 µA
0.06 % + 0.03 µA
0.06 % + 0.03 µA
0.4 % + 0.3 µA
0.15 % + 0.2 µA
0.06 % + 0.2 µA
0.03 % + 0.2 µA
0.06 % + 0.2 µA
0.4 % + 0.3 µA
0.15 % + 0.3 µA
0.06 % + 0.3 µA
0.03 % + 0.2 µA
0.06 % + 0.2 µA
Fluke 5500A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No 3601.09) 04/14/2025 Page 4 of 6
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(cont)
(33 to 330) mA
(0.33 to 2.2) A
(2.2 to 11) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
0.4 % + 3 µA
0.15 % + 3 µA
0.06 % + 3 µA
0.03 % + 2 µA
0.06 % + 2 µA
0.4 % + 0.2 mA
0.16 % + 0.2 mA
0.08 % + 0.2 mA
0.4 % + 0.2 mA
0.16 % + 0.2 mA
0.08 % + 0.2 mA
Fluke 5500A
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance – Generate3
Up to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
0.017 % + 0.000 78 Ω
0.014 % + 0.0012 Ω
0.0076 % + 0.0011 Ω
0.0075 % + 0.0016 Ω
0.0073 % + 0.000 001 6 kΩ
0.0071 % + 0.000 016 kΩ
0.0070 % + 0.000 016 kΩ
0.0071 % + 0.000 16 kΩ
0.0088 % + 0.000 16 kΩ
0.0095 % + 0.0016 kΩ
0.012 % + 0.000 001 6 MΩ
0.014 % + 0.000 023 MΩ
0.057 % + 0.000 039 MΩ
0.12 % + 0.0019 MΩ
0.53 % + 0.0023 MΩ
1.1 % + 0.078 MΩ
Fluke 5500A
Resistance – Measure3
Up to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 33) MΩ
(33 to 100) MΩ
90 µΩ/Ω + 15 mΩ
90 µΩ/Ω + 60 mΩ
90 µΩ/Ω + 6Ω
110 µΩ/Ω + 6Ω
120 µΩ/Ω + 6Ω
150 µΩ/Ω + 55Ω
600 µΩ/Ω + 550Ω
1 mΩ/Ω + 550Ω
Keysight 34401A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No 3601.09) 04/14/2025 Page 5 of 6
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouple Indicators3 –
Generate & Measure
Type J
Type K
Type T
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.28 °C
0.19 °C
0.17 °C
0.22 °C
0.24 °C
0.33 °C
0.20 °C
0.21 °C
0.25 °C
0.37 °C
0.52 °C
0.24 °C
0.18 °C
0.20 °C
Fluke 5500A
III. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments
Pressure – Measuring
Equipment
(> to 500) psig
(> 500 to 5000) psig
(> 5000 to 10 000) psig
0.66 psi
6.5 psi
13 psi
Crystal XP2i 500 psi
Crystal XP2i 10,000
psi
Torque – Measuring
Equipment3
(5 to 150) lbf·in
(25 to 250) lbf·ft
(60 to 600) lbf·ft
0.85 % of Reading
0.69 % of Reading
0.98 % of Reading
Snap-On torque
transducer
CDI torque transducer
Snap-On torque
transducer
Speed-Measuring
Equipment
(2 to 99,999) RPM
1.7 RPM
Tachometer
(centrifuge speed) | ||
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No 3601.09) 04/14/2025 Page 6 of 6
IV. Thermodynamics
Parameter/Equipment
Range
CMC2 (±)
Comments
Temperature – Measure
& Measuring Equipment3
(0 to 150) °C
0.1 °C
Thermoworks
reference thermometer
w/ cold or heat source
V. Time & Frequency
Parameter/Equipment
Range
CMC2 (±)
Comments
RPM3
(1 to 999) RPM
(1000 to 12000) RPM
1.3 RPM
3.0 RPM
Ametek DigiStrobe
Timers & Stopwatches
(> to 83,000) Seconds
810 ms
Control Company
stopwatch
__________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | 0 to 150 °C |
| 7 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Roberts CalibrationPembroke, GA · ~50 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- MSI-Viking GageN. Charleston, SC · ~136 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Co., LLC - AUGUSTAAugusta, GA · ~175 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Quality Tech ServicesByron, GA · ~259 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Aalberts IPSAPageland, SC · ~304 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.