Guangdong Zhonghan Testing Technology Co.,
Room 104/201, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, People's Republic of China, Shenzhen, China
Visit website- Accredited standards
- 88
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 88 standard numbers and the 41 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC23
IEC 50364
IEC 50663
IEC 50665
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 61851-1
IEC 61851-21-2
IEC 61951-1
IEC 61951-2
IEC 61960-3
Show all 23
IEC 61960-4
IEC 62133-1
IEC 62133-2Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
IEC 62281
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368.1national version with changes
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62493
IEC 62619Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications
IEC 62752
ETSI18
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 440
ETSI EN 301 345-1
ETSI EN 301 345-2
ETSI EN 301 345-3
ETSI EN 301 357
Show all 18
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-9
ETSI EN 301 489-17
ETSI EN 301 893
ETSI EN 303 417
IEC 61000 series12
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national
National versions in the same scope
AS/NZS 61000-6-1probably the same standard; matched by number only
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000-6-2probably the same standard; matched by number only
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000-6-3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000-6-4probably the same standard; matched by number only
EN9
EN 15194
EN 17128
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50293
EN 50364
EN 50563
EN 50564
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
CISPR8
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+1 national
National versions in the same scope
AS/NZS CISPR 14.2national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national
National versions in the same scope
AS CISPR 15national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC 60335 series8
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements+1 national
National versions in the same scope
AS/NZS 60335-1probably the same standard; matched by number only
IEC 60335-2-2Household and similar electrical appliances - Safety - Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances+1 national
National versions in the same scope
AS/NZS 60335-2-2probably the same standard; matched by number only
IEC 60335-2-8Household and similar electrical appliances - Safety - Part 2-8: Particular requirements for shavers, hair clippers and similar appliances+1 national
National versions in the same scope
AS/NZS 60335-2-8probably the same standard; matched by number only
IEC 60335-2-9Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances+1 national
National versions in the same scope
AS/NZS 60335-2-9probably the same standard; matched by number only
IEC 60335-2-14+1 national
National versions in the same scope
AS/NZS 60335-2-14probably the same standard; matched by number only
IEC 60335-2-15+1 national
National versions in the same scope
AS/NZS 60335-2-15probably the same standard; matched by number only
IEC 60335-2-23+1 national
National versions in the same scope
AS/NZS 60335-2-23probably the same standard; matched by number only
IEC 60335-2-29+1 national
National versions in the same scope
AS/NZS 60335-2-29probably the same standard; matched by number only
IEC 60086 series4
IEC 60086-1
IEC 60086-2
IEC 60086-4
IEC 60086-5
IEC 62680 series3
IEC 62680-1-1
IEC 62680-1-2
IEC 62680-1-3
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
UN 38.3Lithium metal and lithium ion batteries
ARIB STD-T66; RSS-102 (Issue 6); RSS-102.NS.MEAS; SPR-002; IEEE C95.3; EN 62311; BS EN 62311; IEC 62311; EN 50665; IEC 50665; EN 62479; EN 50663; BS EN 50663; IEC 50663; EN 50364; BS EN 50364; IEC 50364; EN 62233; BS EN 62233; IEC 62233; EN 62493; BS EN 62493; IEC 62493; IEC 62368-1; EN IEC 62368-1; AS/NZS 62368.1; UL 62368-1; BS EN IEC 62368-1; UL 2595; EN 62680-1-1; EN IEC 62680-1-3; EN IEC 62680-1-2; BS EN 62680-1-1; BS EN IEC 62680-1-3; BS EN IEC 62680-1-2; IEC 62680-1-1; IEC 62680-1-3; IEC 62680-1-2; IEC 60335-1; EN 60335-1; BS EN 60335-1; AS/NZS 60335-1; UL 60335-1; IEC 60335-2-2; EN IEC 60335-2-2; BS EN IEC 60335-2-2; AS/NZS 60335-2-2; IEC 60335-2-8; EN IEC 60335-2-8; BS EN IEC 60335-2-8; AS/NZS 60335-2-8; UL 60335-2-8; IEC 60335-2-9; EN IEC 60335-2-9; BS EN IEC 60335-2-9; AS/NZS 60335-2-9; IEC 60335-2-14; EN 60335-2-14; AS/NZS 60335-2-14; IEC 60335-2-15; EN 60335-2-15; BS EN 60335-2-15; AS/NZS 60335-2-15; IEC 60335-2-23; EN 60335-2-23; BS EN 60335-2-23; AS/NZS 60335-2-23; IEC 60335-2-29; EN 60335-2-29; BS EN 60335-2-29; AS/NZS 60335-2-29
IEC 61851-1; EN IEC 61851-1; BS EN IEC 61851-1; IEC 62752; EN 62752; BS EN 62752; AS/NZS 4665-1; AS/NZS 4665-2; (EU) 2019/1782; EN 50563; BS EN 50563; (EC) No 1275/2008; EN 50564; BS EN 50564; IEC 60529; EN 60529; AS 60529; BS EN 60529; UL 1310; UL 1012; UL 2089; ST/SG/AC.10/11/Rev.7/Amend.1/38.3; ST/SG/AC.10/1/Rev.21 Chapter 3.3 238(a); UN/ST/SG/AC.10/1/Rev.21&Rev.22 /3.3; IEC 62133-2; EN 62133-2; BS EN 62133-2; UL 62133-2; IEC 62281; EN IEC 62281; BS EN IEC 62281; IEC 60086-1; EN IEC 60086-1; BS EN IEC 60086-1; IEC 60086-2; EN IEC 60086-2; BS EN IEC 60086-2; IEC 60086-4; EN IEC 60086-4; BS EN IEC 60086-4; IEC 60086-5; EN IEC 60086-5; BS EN IEC 60086-5; IEC 61960-3; EN 61960-3; BS EN 61960-3; J 62133-2; JIS C 62133-2; UL 2056; UL 1642; UL 2054; UL 2271; UL 2595; UL 2743; UL 4200A; UN38.3 ST/SG/AC.10/11/Rev.8; IEC 62619; EN 62619; IEC 61951-1AMD1; EN 61951-1:2017A1; IEC 61960-3; EN61960-3; IEC 61951-2:+AMD1; EN 61951-2A1; IEC 62133-1; EN 62133-1; IEC 61960-4; EN 61960-4; ANSI C18.1M, Part 1; ANSI C18.3M, Part 2; EN 17128; EN 15194
IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6; IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8; IEC 61000-4-11; EN IEC 61000-4-11; BS EN IEC 61000-4-11; IEC 61000-6-1; EN 61000-6-1; AS/NZS 61000-6-1; BS EN 61000-6-1; IEC 61000-6-2; EN 61000-6-2; AS/NZS 61000-6-2; BS EN 61000-6-2; IEC 61000-6-3; EN 61000-6-3; AS/NZS 61000-6-3; BS EN 61000-6-3; IEC 61000-6-4; EN 61000-6-4; AS/NZS 61000-6-4; BS EN 61000-6-4; IEC/CISPR 24; EN 55024; IEC 61547; EN IEC 61547; BS EN IEC 61547; IEC/CISPR 35; EN 55035; BS EN 55035; IEC/CISPR 14-2; EN IEC 55014-2; BS EN IEC 55014-2; AS/NZS CISPR 14.2; IEC 61326-1; EN 61326; EN 61326-1; BS EN 61326; BS EN 61326-1; IEC 60601-1-2; EN 60601-1-2; BS EN 60601-1-2; EN 50130-4; BS EN 50130-4; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-9; ETSI EN 301 489-17; EN IEC 61851-21-2; BS EN IEC 61851-21-2; IEC 61851-21-2; 47 CFR, FCC Part 15 C; 47 CFR, FCC Part 15 E; GS0 2693:2022; UAE.S 5021:2018; SAS0 29382019; Canada/ISED RSS-GEN; RSS-210; RSS-216; RSS-247; RSS-310; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETSI EN 300 440; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 301 357; ETSI EN 303 417; ETSI EN 300 330; ETSI EN 301 345-1; ETSI EN 301 345-2; ETSI EN 301 345-3
CFR 47, FCC Part 15, Subpart B; ANSI C63.4:2014; CFR 47, FCC Part 18; MP-5:1986; IEC/CISPR 22; AS/NZS CISPR 22; EN 55022; IEC/CISPR 32; EN 55032; AS/NZS CISPR 32; BS EN 55032; IEC/CISPR 11; EN 55011; AS/NZS CISPR 11; BS EN 55011; IEC/CISPR 14-1; EN IEC 55014-1; BS EN IEC 55014-1; AS/NZS CISPR 14.1; IEC/CISPR 15; EN IEC 55015; AS CISPR 15; BS EN IEC 55015; EN 50293; BS EN 50293; ICES-001; ICES-003; ICES-005; EN 61000-3-2; EN 61000-3-3; BS EN 61000-3-2; BS EN 61000-3-3; IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02)
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
13 lines
ISO/IEC 17025
Active6713.01
The scope document we hold says it is valid until 2026-11-30.
ISO/IEC 17025
Active6713.02
Labs with overlapping accredited scope in China
- Dongguan DN Testing Co.,DongguanA2LAShares 2 accredited test methodsANSI C63.4:2014EN 62311
- Eurofins TA Technology (Shanghai) Co.,Shanghai 201201A2LAShares 2 accredited test methodsANSI C63.4:2014EN 62311
- GRG Metrology & Test Group Co.,ShenzhenA2LAShares 2 accredited test methodsEN 62311IEC 60529
- SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen BranchShenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014EN 62311
- Shenzhen CCUT Quality Technology Co.,ShenzhenA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 61000-4-6
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.