Aldinger Company dba Precision Calibration Systems

Morristown, TN, United States

Visit website
A2LA 1509.03ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
39
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 39 scope lines.

A2LA certificate 1509.03 · 39 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 ALDINGER COMPANY DBA PRECISION CALIBRATION SYSTEMS 1615-to 12 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 2 of 34 Parameter/Equipment Range CMC2, 4 (±) Comments Standard Length3 (including Feeler Gages, Snap Gages, Taper Gages) Up to 11 in (12 + 2.9L) µin Universal measurement machine Pin & Plug Gages3 Up to 5 in (19 + 18L) µin Universal measurement machine External Threads Major Diameter3 Up to 5 in (17 + 22L) µin Universal measurement machine External Threads Pitch Diameter3 Up to 5 in (51 + 17L) µin Universal measurement machine, thread wires Ring Gages3 Up to 6 in >6 to 11 in (21 + 3.1L) µin (7 + 6.6L) µin Universal measurement machine Dimensional Measurement (including Radius Gages, Fillet Gages, Angle Blocks) X/Y Axis: Up to 12 in X/Y Axis: Up to 8 in Z Axis: Up to 6 in Z Axis: Up to 2 in Angle Measurement: Up to 180° Angle Measurement: Up to 180° Z Axis: Up to 40 in Angle: Up to 180° (180 + 11L) µin (190 + 22L) µin 470 µin 380 µin 0.007° 0.005° (49 + 21L) µin 0.08° Vision system 2D height gauge Digital protractor Surface Finish – Measurement (10 to 320) μin Ra 2.2 µin Ra Profilometer Surface Finish Equipment3 (10 to 320) μin Ra 2.2 µin Ra Master finish standards
10 to 320 μin Ra
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 3 of 34 Parameter/Equipment Range CMC2, 4 (±) Comments Height Gauges3 Up to 40 in (15 + 22L) µin Length standard, gage blocks Dial/Digital Indicators3 Up to 4 in Up to 1 in (220 + 3L) µin (170 + 160L) µin Gage blocks Indicator calibrator Vision Machine3 X/Y Axis Z Axis Angle Measuring Microscope3 Up to 12 in Up to 6 in (1 to 90)° (0.01 to 1) mm 140 µin 150 µin 0.026° 9 μm Gage blocks / glass masters, angle blocks Gage Block Up to 6 in (4.4 + 3.6L) µin Universal measurement machine, master gage blocks Thread Ring – Pitch Diameter Minor Diameter Up to 5 in (0.2 to 1.2 in (51 + 17L) µin 250 µin Universal measurement machine, inside micrometer Tapered Thread Plug Up to 4 in (140 + 18L) µin Universal measurement machine, thread wires, height gauge
to 40 in
4-Steel
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 4 of 34 Parameter/Equipment Range CMC2, 4 (±) Comments ULM3 – Length Parallelism Flatness Tailstock Force Up to 4 in (4 to 12) in (12 to 24) in Up to 4 in Up to 4 in Up to 40 ozf (10 + 2.8L) µin (16 + 1.3L) µin (7 + 2.3L) µin 3 µin 10 µin 2.9 % Gage blocks/length standards Gage ball Optical flat Load cell Steel Rules & Tape Measures 3 Up to 40 ft (0.011 + 0.000 25L) in Length standard, reticle, push-pull block Displacement3 (Extensometers) Up to 0.005 in (0.005 to 0.02) in (0.02 to 0.2) in (0.2 to 2) in 17 µin 41 µin 48 µin 240 µin Linear displacement calibrator Optical Comparators3 – X & Y Linearity Magnification Angle Up to 20 in Up to 6 in (1 to 90)° 0.0006 in 0.0025 in 0.047° Glass master, gage blocks Glass master, caliper, pin gage Angle blocks Protractors3 (1 to 90)° (Up to 45)° 0.044° 0.024° Angle blocks, surface plate Sine plate, gage blocks Precision Levels Up to 0.1 in per ft Deviation Level 0.0006 in 60 µin Surface plate, sine plate, gage blocks Surface plate Crimpers3 – Crimp Height Crimp Die Diameter Up to 1 in Up to 1 in 180 μin 240 μin Crimp micrometer Pin/plug sets Coating Thickness Testers 3 Up to 80 mils 0.7 % + 0.012 mils Coating thickness standards
to 40 ft
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 1 of 34 Parameter/Equipment Range CMC2, 4 (±) Comments Coating Thickness Testers3 Up to 80 mils 0.7 % + 0.012 mils Thickness standards Coating Thickness Standards Up to 200 mils (0.007 + 0.000 14L) mils Universal measurement machine, gage blocks III. Electrical – DC/Low Frequency Parameter/Range Frequency CMC2, 8 (±) Comments AC Current – Generate3 (29 to 330) μA 330 μA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 1.1 A (10 to 20) Hz (20 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz 1.8 mA/A + 0.1 µA 1.4 mA/A + 0.1 µA 1.2 mA/A + 0.1 µA 2.7 mA/A + 0.15 µA 6.7 mA/A + 0.2 µA 13 mA/A + 0.4 µA 1.6 mA/A + 0.15 µA 1.0 mA/A + 0.15 µA 0.82 mA/A + 0.15 µA 1.6 mA/A + 0.2 µA 4 mA/A + 0.3 µA 7.9 mA/A + 0.6 µA 1.5 mA/A + 2 µA 0.76 mA/A + 2 µA 0.38 mA/A + 2 µA 0.68 mA/A + 2 µA 1.6 mA/A + 3 µA 3.2 mA/A + 4 µA 1.5 mA/A + 20 µA 0.76 mA/A + 20 µA 0.38 mA/A + 20 µA 0.9 mA/A + 50 µA 1.8 mA/A + 100 µA 3.6 mA/A + 200 µA 1.5 mA/A + 100 µA 0.53 mA/A + 100 µA 5.4 mA/A + 1 mA 23 mA/A + 5 mA Multi-function calibrator
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 2 of 34 Parameter/Range Frequency CMC2, 8 (±) Comments AC Current – Generate3 (con’t) (1.1 to 3) A (3 to 11) A (11 to 20.5) A Clamp-on Only (16.5 to 55) A (55 to 150) A (150 to 550) A (550 to 1020) A (10 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 440) Hz (45 to 440) Hz (45 to 440) Hz (45 to 440) Hz 1.5 mA/A + 100 µA 0.64 mA/A + 100 µA 4.5 mA/A + 1 mA 21 mA/A + 5 mA 0.83 mA/A + 2 mA 1.9 mA/A + 2 mA 24 mA/A + 2 mA 16 mA/A + 5 mA 17 mA/A + 5 mA 24 mA/A + 5 mA 0.6 A 1.1 A 3.0 A 8.7 A Multi-function calibrator w/ 50-turn coil AC Voltage – Generate3 (1 to 33) mV (33 to 330) mV (0.33 to 3.3) mV (3.3 to 33) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 1.7 mV/V + 6 µV 1.3 mV/V + 6 µV 1.7 mV/V + 6 µV 2.1 mV/V + 6 µV 3.6 mV/V + 12 µV 9.3 mV/V + 50 µV 0.44 mV/V + 8 µV 0.29 mV/V + 8 µV 0.6 mV/V + 8 µV 0.88 mV/V + 8 µV 2.2 mV/V + 32 µV 4.7 mV/V + 70 µV 0.44 mV/V + 50 µV 0.39 mV/V + 60 µV 0.59 mV/V + 60 µV 0.83 mV/V + 50 µV 1.5 mV/V + 125 µV 4.1 mV/V + 600 µV 0.41 mV/V + 650 µV 0.26 mV/V + 600 µV 0.56 mV/V + 600 µV 0.8 mV/V + 600 µV 1.8 mV/V + 1.6 mV Multi-function calibrator
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 3 of 34 Parameter/Range Frequency CMC2, 8 (±) Comments AC Voltage – Generate3 (con’t) (33 to 330) V (330 to 1020) V 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.4 mV/V + 2 mV 0.65 mV/V + 6 mV 0.73 mV/V + 6 mV 0.97 mV/V + 6 mV 2.1 mV/V + 50 mV 0.41 mV/V + 10 mV 0.64 mV/V + 10 mV 0.72 mV/V + 10 mV Multi-function calibrator AC Current – Measure3 (5 to 100) μA 100 μA to 1 mA (1 to 10 mA) (10 to 100) mA (100 to 400) mA 400 mA to 1 A (1 to 3) A (3 to 10) A (10 to 1000) A 10 Hz to 5 kHz (50 to 400) Hz 0.18 % + 0.07 μA 0.12 % + 0.5 μA 0.18 % + 7 μA 0.12 % + 19 μA 0.12 % + 0.47 mA 0.12 % + 0.57 mA 0.18 % + 7 mA 0.18 % + 9 mA 6 % Precision multimeter Clamp meter AC Voltage – Measure3 Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 20) kV (1 to 10) kV 10 Hz to 20 kHz (20 to 100) kHz 50-60 Hz 50-60 Hz 0.07 % + 47 µV 0.07 % + 0.46 mV 0.07 % + 4.6 mV 0.07 % + 36 mV 0.07 % + 0.32 V 0.7 % + 94 µV 0.7 % + 0.94 mV 0.7 % + 9.4 mV 0.7 % + 94 mV 0.7 % + 1.1 V 5.9 % 0.15 % Precision multimeter Multimeter & high voltage probe High voltage meter
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 4 of 34 Parameter/Equipment Range CMC2, 8 (±) Comments DC Current – Generate3 Up to 329.999 μA 329.999 μA to 3.299 99 mA (3.299 999 9 to 32.999 99) mA (32.999 99 to 329.9999) mA 329.999 mA to 1.099 99 A (1.1 to 2.999 99) A (2.999 99 to 10.9999) A (10.9999 to 20) A (20 to 1010) A 270 µA/A + 0.02 µA 140 µA/A + 0.05 µA 97 µA/A + 0.25 µA 98 µA/A + 2.5 µA 380 µA/A + 40 µA 310 µA/A + 40 µA 510 µA/A + 500 µA 810 µA/A + 750 µA 0.5 % + 0.5 A Multi-function calibrator w/ 50 turn coil DC Voltage – Generate 3 Up to 330 mV 330 mV to 3.299 999 V (3.299 999 to 32.999 99) V (32.999 99 to 329.9999) V (329.9999 to 1020) V 54 µV/V + 1 µV 40 µV/V + 2 µV 44 µV/V + 20 µV 44 µV/V + 150 µV 44 µV/V + 1.5 mV Multi-function calibrator Capacitance – Generate3 (0.22 to 1.099) nF (1.1 to 3.299) nF (3.3 to 10.999) nF (11 to 32.999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099) µF (1.1 to 3.299) µF (3.3 to 10.999) µF (11 to 32.999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099) mF (1.1 to 3.299) mF (3.3 to 10.999) mF (11 to 32.999) mF (33 to 110) mF 0.013 nF 0.023 nF 0.031 nF 0.17 nF 0.53 nF 1.1 nF 3.3 nF 9.2 nF 35 nF 0.14 µF 0.49 µF 1.4 µF 4.7 µF 14 µF 47 µF 0.22 mF 1.0 mF Multi-function calibrator
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 5 of 34 Parameter/Equipment Range CMC2, 8 (±) Comments Resistance – Generate3 Up to 10.999 Ω (11 to 32.999) Ω (32.999 to 109.999) Ω (109.999 to 329.999) Ω 330 Ω to 1.099 99 kΩ (1.1 to 3.299 99) kΩ (3.3 to 10.999) kΩ (11 to 32.999) kΩ (33 to 109.999) kΩ (110 to 329.999) kΩ 330 kΩ to 1.0999 MΩ (1.1 to 3.2999) MΩ (3.3 to 10.9999) MΩ (11 to 32.999) MΩ (33 to 109.999) MΩ (110 to 329.999) MΩ (330 to 1100) MΩ 170 µΩ/Ω + 1 mΩ 130 µΩ/Ω + 1.5 mΩ 82 µΩ/Ω + 1.4 mΩ 76 µΩ/Ω + 2 mΩ 73 µΩ/Ω + 2 mΩ 76 µΩ/Ω + 20 mΩ 73 µΩ/Ω + 20 mΩ 76 µΩ/Ω + 0.2 Ω 88 µΩ/Ω + 0.2 Ω 98 µΩ/Ω + 2 Ω 0.12 mΩ/Ω + 2 Ω 0.13 mΩ/Ω + 30 Ω 0.47 mΩ/Ω + 50Ω 0.84 mΩ/Ω + 2.5 kΩ 3.9 mΩ/Ω + 3 kΩ 4.2 mΩ/Ω + 0.1 MΩ 12 mΩ/Ω + 0.5 MΩ Multi-function calibrator Temperature Calibration, Indication, & Control Equipment Used With RTD – (Electrical Simulation)3 Cu 42 710 Ω PT 385 100 Ω PT 385 200 Ω PT 385 500 Ω PT 3 851 000 Ω PT 3 916 100 Ω PT 3 926 100 Ω PtNi 385 120 Ω (-100 to 260) °C (-200 to 630) °C (630 to 800) °C (-200 to 260) °C (260 to 630) °C (-200 to 260) °C (260 to 630) °C (-200 to 600) °C (600 to 630) °C (-200 to -190) °C (-190 to 600) °C (600 to 630) °C (-200 to 100) °C (100 to 630) °C (-80 to 100) °C (100 to 260) °C 0.31 °C 0.15 °C 0.25 °C 0.07 °C 0.17 °C 0.07 °C 0.12 °C 0.07 °C 0.24 °C 0.26 °C 0.11 °C 0.24 °C 0.08 °C 0.13 °C 0.09 °C 0.15 °C Multi-function calibrator
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 6 of 34 Parameter/Equipment Range CMC2, 8 (±) Comments Temperature – Instruments (Electrical Simulation) – Thermocouple Devices3 Type B Type C Type E Type J Type K Type N Type R Type S Type T Type U (600 to 800) °C (800 to 1800) °C (0 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-200 to 0) °C (0 to 600) °C 0.41 °C 0.33 °C 0.25 °C 0.41 °C 0.66 °C 0.39 °C 0.13 °C 0.17 °C 0.21 °C 0.15 °C 0.19 °C 0.26 °C 0.15 °C 0.21 °C 0.32 °C 0.32 °C 0.18 °C 0.21 °C 0.30 °C 0.45 °C 0.29 °C 0.37 °C 0.49 °C 0.38 °C 0.32 °C 0.39 °C 0.49 °C 0.38 °C 0.31 °C 0.39 °C 0.44 °C 0.22 °C Multi-function calibrator
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 7 of 34 Parameter/Equipment Range CMC2, 8 (±) Comments DC Current – Measure3 (1 to 100) μA 100 μA to 1 mA (1 to 100) mA (100 to 400) mA 400 mA to 1 A (1 to 3) A (3 to 10) A (10 to 1000) A 0.06 % + 0.06 µA 0.06 % + 0.6 µA 0.06 % + 6 µA 0.06 % + 24 µA 0.06 % + 28 µA 0.12 % + 2.4 mA 0.18 % + 4.4 mA 2.6 % Precision multimeter Clamp meter DC Voltage – Measure3 (0.01 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 20) kV (1 to 10) kV 0.004 % + 5µV 0.003 % + 13µV 0.003 % + 86µV 0.004 % + 0.94 mV 0.005 % + 14 mV 2.4 % 0.05 % Precision multimeter Multimeter & high voltage probe High voltage meter Capacitance – Measure3 Up to 1 nF (1 to 10) nF (10 to 100) nF 100 nF to 1 μF (1 to 10) μF (10 to 100) μF 100 µF to 1 mF (1 to 10) mF (10 to 100) mF 2.4 % + 0.034 nF 1.2 % + 0.09 nF 1.2 % + 0.65 nF 1.2 % + 7.4 nF 1.2 % + 73 nF 1.2 % + 0.77 μF 1.2 % + 7.8 µF 1.2 % + 78 µF 4.7 % + 1.30 mF Precision multimeter Resistance – Measure3 Equipment to Source Up to 10 Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ (100 to 1000) MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ (8 to 1200) Ω 0.012 % + 3.5 mΩ 0.012 % + 5.7 mΩ 0.012 % + 15 mΩ 0.012 % + 0.34 Ω 0.012 % + 0.36 Ω 0.012 % + 0.58 Ω 0.046 % + 0.79 kΩ 0.93 % + 0.14 MΩ 2.30 % + 0.14 MΩ 0.04 MΩ 0.26 MΩ 2 MΩ 0.19 GΩ 3.6 mΩ Precision multimeter Insulation resistance standard Transfer standard
to 1000 A
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 8 of 34 IV. Fluid Quantities Parameter/Equipment Range CMC2, 6 (±) Comments Liquid Flow Meter3 Up to 500 GPM 2 % Ultrasonic flow meter Liquid Flow Meter3 Rate Totalization Up to 30 GPM (31 to 200) GPM Up to 6 kg 0.16 % 0.13 % 0.11 % Coriolis flow meter Balance POVA (Piston/Plunger Operated Volumetric Apparatus)3 – Including But Not Limited To: Pipettes, Syringes, Dispensers, & Burettes (0.1 to 20) μL (20 to 200) μL (200 to 1000) μL (1000 to 10 000) μL (10 000 to 20 000) μL (10 to 100) mL 0.16 μL 0.22 μL 0.53 μL 5 μL 11 μL (0.58 % + 0.3) mL Micro balance Balance Graduated Cylinder/Flask/Beaker3 (50 to 6000) mL (0.98 % + 0.16) mL Balance Viscometers3 Up to 10 000 cP 1.7 % Viscosity reference standards Anemometers (400 to 3000) fpm 2.30 % Differential pressure transducer, wind tunnel, pitot tube V. Mechanical Parameter/Equipment Range CMC2, 6 (±) Comments Force Gages3 Up to 500 lbf 0.11 % Calibrated weights Load Cells, Load Stands & Tension/Compression Testers 3 Up to 500 lbf (20 to 1000) lbf 0.11 % 0.21 % Calibrated weights Load cells w/indicator
to 500 GPM
13ASTM Class 6 weights; Class F weights-See scope document
14--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 10 of 34 Parameter/Equipment Range CMC2, 6 (±) Comments Crimpers3 – Pull Force Jaw Force Up to 500 lbf Up to 15 Tons 6.4 % 2.8 % Force gauge Load cell Mass – Fixed Points (1 to 500) mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 300 g 500 g 1000 g 2000 g 5000 g 10 000 g 20 000 g 30 000 g 0.5 lb 1 lb 2 lb 5 lb 10 lb 20 lb 25 lb 50 lb 41 μg 39 μg 40 μg 42 μg 44 μg 51 μg 77 μg 0.13 mg 0.25 mg 2.8 mg 3.0 mg 3.1 mg 3.9 mg 6.9 mg 39 mg 45 mg 55 mg 0.80 mg 3.2 mg 4.3 mg 8.6 mg 16 mg 49 mg 54 mg 88 mg Class 1 weights, mass comparator Pressure Gauge3 Absolute Up to 1 in H2O (1 to 10) in H2O Up to 1 psi (1 to 15) psi (15 to 300) psi (300 to 1000) psi (1000 to 10 000) psi Up to 30 psia (10 to 10 000) psi 0.0017 in H2O 0.012 in H2O 0.0024 psi 0.0045 psi 0.092 psi 0.28 psi 2.8 psi 0.02 psia 0.015 % Reference pressure gauges Deadweight tester
to 500 lbf
15-Hardness test block masters
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 11 of 34 Parameter/Equipment Range CMC2, 6 (±) Comments Vacuum Gauge3 (-14 to -1) psi (-1 to 0) psi (-10 to -1) in H 2O (-1 to 0) in H2O 0.009 psi 0.0024 psi 0.012 H2O 0.0017 in H20 Reference pressure gauges Indirect Verification of Rockwell Hardness Testers 3 HRC (20 to 35) HRC (35 to 59) HRC (60 to 70) HRC HRBW (40 to 59) HRB (60 to 87) HRB (88 to 99) HRB HRA (20 to 69) HRA (70 to 79) HRA (80 to 99) HRA HR15N (70 to 77) HR15N (78 to 89) HR15N (90 to 99) HR15N HR30N (40 to 54) HR30N (55 to 76) HR30N (77 to 90) HR30N HR15TW (65 to 80) HR15TW (81 to 86) HR15TW (87 to 99) HR15TW HR30TW (43 to 56) HR30TW (57 to 69) HR30TW (70 to 90) HR30TW 0.45 HRC 0.41 HRC 0.33 HRC 0.37 HRB 0.37 HRB 0.34 HRB 0.34 HRA 0.34 HRA 0.33 HRA 0.37 HR15N 0.34 HR15N 0.35 HR15N 0.37 HR30N 0.38 HR30N 0.35 HR30N 0.35 HR15TW 0.33 HR15TW 0.40 HR15TW 0.44 HR30TW 0.37 HR30TW 0.35 HR30TW Hardness test block masters Knoop Hardness Testers HK, (Indirect verification)3 (250 to 650) HK (651 to 750) HK 10 HK 16 HK Hardness test block masters
See scope document
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 12 of 34 Parameter/Equipment Range CMC2, 6 (±) Comments Vickers Hardness Testers HV, (Indirect Verification)3 (240 to 600) HV (601 to 750) HV 10 HV 16 HV Hardness test block masters Brinell Hardness Testers HBW, (Indirect Verification)3 (125 to 225) HBW >225 HBW 4.1 HBW 10 HBW Hardness test block masters, Brinell scope Durometers10 – Force Displacement Length Indenter Geometry Up to 90 Duros Type A, B, E, O Type C, D, DO Type M, OO, OOO, OOO-S Up to 0.2 in Length, Diameter, Radius Angle (1 % + 0.3) Duros (0.25 % + 0.38) Duros (0.4 % + 1.3) Duros 0.0007 in 200 µin 0.01° Balance Gage blocks Vision system Torque Wrenches3 (4 to 40) ozf∙in (1 to 10) lbf∙in (2 to 20) lbf∙in (2.5 to 25) lbf∙in (1.5 to 29.5) lbf∙ft (5 to 50) lbf∙ft (25 to 250) lbf∙ft (22 to 1100) lbf∙ft (200 to 1000) lbf∙ft 0.7 % + 0.051 ozf∙in 0.7 % + 0.014 lbf∙in 0.7 % + 0.024 lbf∙in 0.7 % + 0.032 lbf∙in 0.7 % + 0.04 lbf∙ft 0.7 % + 0.07 lbf∙ft 0.7 % + 0.034 lbf∙ft 0.81 % + 0.4 lbf∙ft 0.82 % Torque transducers Torque Testers3 Up to 150 lbf∙in Up to 750 lbf∙ft 0.18 % 0.14 % Torque arm, weights
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 13 of 34 Parameter/Equipment Range CMC2, 6, 7 (±) Comments Rate of Rotation – Measurement Equipment3 Contact Non-Contact (10 to 3800) RPM (5 to 999) RPM (1000 to 9999) RPM (10 000 to 99 999) RPM 0.05 % + 0.015 RPM 0.013 % + 0.0014 RPM 0.006 % + 0.008 RPM 0.003 % + 0.4 RPM Reference tachometer Reference strobe Rate of Rotation – Measure3 Length Non-Contact Up to 1000 FPM (6 to 8299) RPM (8300 to 24 999) RPM (25 000 to 99 999) RPM 0.21 % + 0.9 FPM 1.70 RPM 2.7 RPM 0.007 % + 1.5 RPM Reference tachometer w/wheel Reference tachometer VI. Optical Parameter/Equipment Range CMC2, 6 (±) Comments Spectrophotometer3 – Photometric Accuracy Wavelength Accuracy (250 to 635) nm (240 to 640) nm 0.0044 AU 0.28 nm Neutral density filter, holmium oxide filter Light Meters Visible Light UVA Light (400 to 700) nm/ (0.01 to 50 000) Lux (315 to 390) nm/ (2.0 E-2 to 2.0 E-8) W/cm 2 6.1 % 6.9 % Light meter, broadband sensor
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 14 of 34 Parameter/Equipment Range CMC2, 6 (±) Comments Light Booth3 Visible Light UVA Light (400 to 700) nm/ (0.01 to 50 000) Lux (315 to 390) nm/ (2.0 E-2 to 2.0 E-8) W/cm 2 6.1 % 6.6 % Light meter, broadband sensor VII. Thermodynamics Parameter/Equipment Range CMC2, 6, 7 (±) Comments Temperature Measuring Equipment – Infrared Thermometers3 (50 to 500) °C Fixed Points 50 °C 150 °C 250 °C 350 °C 500 °C 1.5 % + 0.9 °C 1.70 °C 3 °C 4.5 °C 5.6 °C 8.6 °C Black body calibrator Thermohygrometers – Humidity (% RH) 3 (20 to 90) % RH 2 % RH Reference thermohygrometer Thermohygrometers – Temperature3 (5 to 55) °C 0.15 °C Reference thermohygrometer Temperature – Measurement3 (-200 to 0) °C (0 to 200) °C (200 to 420) °C (420 to 660) °C 0.020 °C 0.033 °C 0.048 °C 0.065 °C PRT w/readout
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 15 of 34 Parameter/Equipment Range CMC2, 6, 7 (±) Comments Temperature – Measurement3 (con’t) (-100 to 300) °C (300 to 1372) °C (-250 to 0) °C (0 to 400) °C (200 to 700) °C (700 to 1767) °C (50 to 500) °C 1.70 °C 3.20 °C 1.10 °C 0.76 °C 2.50 °C 3.90 °C 5.6 % + 0.3 °C Portable calibrator, K thermocouple Portable calibrator, T thermocouple Portable calibrator, S thermocouple IR thermometer Temperature – Measuring Equipment3 (-90 to 40) °C (40 to 300) °C (300 to 660) °C (660 to 1200) °C 0.025 °C 0.04 °C 0.065 °C 3.9 °C PRT w/readout Portable calibrator, S thermocouple VIII. Time & Frequency Parameter/Equipment Range CMC2,6 (±) Comments Timers & Stopwatches3 (0.01 to 3600) s (3600 to 86 400) s 0.13 s 3.10 s Calibrated stopwatch Frequency – Source3 (0.1 to 119.99) Hz (120 to 1199.99) Hz (1.2 to 11.999) kHz (1.2 to 119.99) kHz (120 to 1199.9) kHz (1.2 to 2.000) MHz 0.004 Hz 0.025 Hz 0.24 Hz 2.4 Hz 24 Hz 40 Hz Multi-function calibrator Frequency – Measure3 (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40 Hz to 300 kHz 300 kHz to 1 MHz 0.13 % 0.07 % 0.04 % 0.02 % 0.04 % Precision multimeter
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 16 of 34 SATELLITE ALDINGER COMPANY DBA PRECISION CALIBRATION SYSTEMS 107 N. Porter St, Suite 5 Winchester, TN 37398 Matthew Shaw Phone: 423 617 9006 CALIBRATION I. Chemical Parameter/Equipment Range CMC2 (±) Comments pH Meter3 4 pH 7 pH 10 pH 0.022 pH 0.022 pH 0.027 pH Std buffer solution Conductivity Meter3 1 µS/cm 10 µS/cm 100 µS/cm 1000 µS/cm 1413 µS/cm 10 000 µS/cm 0.56 μS/cm 0.63 μS/cm 2.10 μS/cm 5.8 μS/cm 7.5 μS/cm 55 μS/cm Std conductivity solution II. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Micrometers3 Up to 12 in (>12 to 36) in (>36 to 60) in (70 + 22L) µin (90 + 24L) µin (190 + 27L) µin Gage blocks, length standards Caliper, Bore Gage, Snap Gage3 Up to 60 in (290 + 27L) µin Gage blocks, length standards Standard Length3 (including Feeler Gages, Snap Gages, Taper Gages) Up to 11 in (12 + 2.9L) µin Universal measurement machine
21--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 17 of 34 Parameter/Equipment Range CMC2, 4, 7(±) Comments Pin & Plug Gages3 Up to 5 in (19 + 18L) µin Universal measurement machine External Threads Major Diameter3 Up to 5 in (17 + 22L) µin Universal measurement machine External Threads Pitch Diameter3 Up to 5 in (51 + 17L) µin Universal measurement machine, thread wires Ring Gages3 Up to 6 in >6 to 11 in (21 + 3.1L) µin (7 + 6.6L) µin Universal measurement machine Dimensional Measurement3 Z Axis: Up to 24 in Angle: Up to 180° (360 + 3L) μin 0.08° 2D height gauge Digital protractor Surface Finish Equipment 3 (10 to 320) μin Ra 2.20 µin Ra Master finish standards Height Gages3 Up to 40 in (15 + 22L) µin Length standard, gage blocks Dial/Digital Indicators3 Up to 4 in Up to 1 in (220 + 3L) µin (170 + 160L) µin Gage blocks Indicator calibrator Vision Machine3 X/Y Axis Z Axis Angle Measuring Microscope 3 Up to 12 in Up to 6 in (1 to 90)° (0.01 to 1) mm 140 µin 150 µin 0.029° 9 μm Gage blocks / glass masters, angle blocks
to 5 in
22-Steel
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 18 of 34 Parameter/Equipment Range CMC2, 4 (±) Comments ULM3 – Length Parallelism Flatness Tailstock Force Up to 4 in (4 to 12) in (12 to 24) in Up to 4 in Up to 4 in Up to 40 ozf (10 + 2.8L) µin (16 + 1.3L) µin (7 + 2.3L) µin 3 µin 10 µin 2.9 % Gage blocks/length standards Gage ball Optical flat Load cell Steel Rules & Tape Measures 3 Up to 40 ft (0.011 + 0.000 25L) in Length standard, reticle, push-pull block Displacement3 (Extensometers) Up to 0.005 in (0.005 to 0.02) in (0.02 to 0.2) in (0.2 to 2) in 17 µin 41 µin 48 µin 240 µin Linear displacement calibrator Optical Comparators3 – X & Y Linearity Magnification Angle Up to 20 in Up to 6 in (1 to 90)° 0.0006 in 0.0025 in 0.047° Glass master, gage blocks Glass master, caliper, pin gage Angle blocks Protractors3 (1 to 90)° (Up to 45)° 0.044° 0.024° Angle blocks, surface plate Sine plate, gage blocks Precision Levels Up to 0.1 in per ft Deviation Level 0.0006 in 60 µin Surface plate, sine plate, gage blocks Surface plate Crimpers3 – Crimp Height Crimp Die Diameter Up to 1 in Up to 1 in 180 μin 240 μin Crimp micrometer Pin/plug sets Coating Thickness Testers 3 Up to 80 mils 0.7 % + 0.012 mils Coating thickness standards
to 4 in
23

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 19 of 34 III. Electrical – DC/Low Frequency Parameter/Range Frequency CMC2, 8 (±) Comments AC Current – Generate3 (29 to 330) μA 330 μA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 330 mA to 1.1 A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz (0.45 to 1) kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 1.8 mA/A + 0.1 µA 1.40 mA/A + 0.1 µA 1.20 mA/A + 0.1 µA 2.70 mA/A + 0.15 µA 6.70 mA/A + 0.2 µA 13 mA/A + 0.4 µA 1.6 mA/A + 0.15 µA 1 mA/A + 0.15 µA 0.82 mA/A + 0.15 µA 1.60 mA/A + 0.2 µA 4 mA/A + 0.3 µA 7.9 mA/A + 0.6 µA 1.5 mA/A + 2 µA 0.76 mA/A + 2 µA 0.38 mA/A + 2 µA 0.68 mA/A + 2 µA 1.60 mA/A + 3 µA 3.2 mA/A + 4 µA 1.5 mA/A + 20 µA 0.76 mA/A + 20 µA 0.38 mA/A + 20 µA 0.9 mA/A + 50 µA 1.80 mA/A + 100 µA 3.60 mA/A + 200 µA 1.5 mA/A + 100 µA 0.53 mA/A + 100 µA 5.40 mA/A + 1 mA 23 mA/A + 5 mA 1.5 mA/A + 100 µA 0.64 mA/A + 100 µA 4.90 mA/A + 1 mA 21 mA/A + 5 mA 0.83 mA/A + 2 mA 1.1 mA/A + 2 mA 24 mA/A + 2 mA 16 mA/A + 5 mA 17 mA/A + 5 mA 24 mA/A + 5 mA Multi-function calibrator
24--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 20 of 34 Parameter/Range Frequency CMC2, 6, 8 (±) Comments AC Current – Generate3 (cont.) Clamp-on Only (16.5 to 55) A (55 to 150) A (150 to 550) A (550 to 1020) A (45 to 440) Hz (45 to 440) Hz (45 to 440) Hz (45 to 440) Hz 0.6 A 1.1 A 3 A 8.7 A w/ 50-turn coil AC Voltage – Generate3 (1 to 33) mV (33 to 330) mV (0.33 to 3.3) mV (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 1.7 mV/V + 6 µV 1.3 mV/V + 6 µV 1.7 mV/V + 6 µV 2.1 mV/V + 6 µV 3.6 mV/V + 12 µV 9.3 mV/V + 50 µV 0.44 mV/V + 8 µV 0.29 mV/V + 8 µV 0.6 mV/V + 8 µV 0.88 mV/V + 8 µV 2.2 mV/V + 32 µV 4.7 mV/V + 70 µV 0.44 mV/V + 50 µV 0.39 mV/V + 60 µV 0.59 mV/V + 60 µV 0.83 mV/V + 50 µV 1.9 mV/V + 125 µV 4.1 mV/V + 600 µV 0.41 mV/V + 650 µV 0.26 mV/V + 600 µV 0.56 mV/V + 600 µV 0.8 mV/V + 600 µV 1.8 mV/V + 1.6 mV 0.4 mV/V + 2 mV 0.65 mV/V + 6 mV 0.73 mV/V + 6 mV 0.97 mV/V + 6 mV 2.1 mV/V + 50 mV 0.41 mV/V + 10 mV 0.64 mV/V + 10 mV 0.72 mV/V + 10 mV Multi-function calibrator
to 1020 V
25

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 21 of 34 Parameter/Range Frequency CMC2, 6, 8 (±) Comments AC Current – Measure3 (5 to 100) μA 100 μA to 1 mA (1 to 10 mA) (10 to 100) mA (100 to 400) mA 400 mA to 1 A (1 to 3) A (3 to 10) A (10 to 1000) A 10 Hz to 5 kHz (50 to 400) Hz 0.18 % + 0.07 μA 0.12 % + 0.5 μA 0.18 % + 7 μA 0.12 % + 19 μA 0.12 % + 0.47 mA 0.12 % + 0.57 mA 0.18 % + 7 mA 0.18 % + 9 mA 6 % Precision multimeter Clamp meter AC Voltage – Measure3 Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 20) kV (1 to 10) kV 10 Hz to 20 kHz (20 to 100) kHz (50 to 60) Hz (50 to 60) Hz 0.07 % + 47 µV 0.07 % + 0.46 mV 0.07 % + 4.6 mV 0.07 % + 36 mV 0.07 % + 0.32 V 0.7 % + 94 µV 0.7 % + 0.94 mV 0.7 % + 9.4 mV 0.7 % + 94 mV 0.7 % + 1.1 V 5.9 % 0.15 % Precision multimeter Multimeter & high voltage probe High voltage meter
26--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 22 of 34 Parameter/Equipment Range CMC2, 8 (±) Comments DC Current – Generate3 Up to 329.999 μA 329.999 μA to 3.299 99 mA (3.299 999 9 to 32.999 99) mA (32.999 99 to 329.9999) mA 329.999 mA to 1.099 99 A (1.1 to 2.999 99) A (2.999 99 to 10.9999) A (10.9999 to 20) A (20 to 1010) A 270 µA/A + 0.02 µA 140 µA/A + 0.05 µA 97 µA/A + 0.25 µA 98 µA/A + 2.5 µA 38 µA/A + 40 µA 310 µA/A + 40 µA 510 µA/A + 500 µA 81 µA/A + 750 µA 0.5 % + 0.5 A Multi-function calibrator w/ 50 turn coil DC Voltage – Generate3 Up to 330 mV 330 mV to 3.299 999 V (3.299 999 to 32.999 99) V (32.999 99 to 329.9999) V (329.9999 to 1020) V 54 µV/V + 1 µV 40 µV/V + 2 µV 44 µV/V + 20 µV 44 µV/V + 150 µV 44 µV/V + 1.5 mV Multi-function calibrator Capacitance – Generate3 (0.22 to 1.099) nF (1.1 to 3.299) nF (3.3 to 10.999) nF (11 to 32.999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099) µF (1.1 to 3.299) µF (3.3 to 10.999) µF (11 to 32.999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099) mF (1.1 to 3.299) mF (3.3 to 10.999) mF (11 to 32.999) mF (33 to 110) mF 0.013 nF 0.023 nF 0.031 nF 0.17 nF 0.53 nF 1.1 nF 3.3 nF 9.2 nF 35 nF 0.14 µF 0.49 µF 1.4 µF 4.7 µF 14 µF 47 µF 0.22 mF 1.1 mF Multi-function calibrator
to 1010 A
27

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 23 of 34 Parameter/Equipment Range CMC2, 8 (±) Comments Resistance – Generate3 Up to 10.999 Ω (11 to 32.999) Ω (32.999 to 109.999) Ω (109.999 to 329.999) Ω 330 Ω to 1.099 99 kΩ (1.1 to 3.299 99) kΩ (3.3 to 10.999) kΩ (11 to 32.999) kΩ (33 to 109.999) kΩ (110 to 329.999) kΩ 330 kΩ to 1.0999 MΩ (1.1 to 3.2999) MΩ (3.3 to 10.9999) MΩ (11 to 32.999) MΩ (33 to 109.999) MΩ (110 to 329.999) MΩ (330 to 1100) MΩ 170 µΩ/Ω + 1 mΩ 130 µΩ/Ω + 1.5 mΩ 82 µΩ/Ω + 1.4 mΩ 76 µΩ/Ω + 2 mΩ 73 µΩ/Ω + 2 mΩ 76 µΩ/Ω + 20 mΩ 73 µΩ/Ω + 20 mΩ 76 µΩ/Ω + 0.2 Ω 88 µΩ/Ω + 0.2 Ω 98 µΩ/Ω + 2 Ω 0.12 mΩ/Ω + 2 Ω 0.13 mΩ/Ω + 30 Ω 0.47 mΩ/Ω + 50Ω 0.84 mΩ/Ω + 2.5 kΩ 3.9 mΩ/Ω + 3 kΩ 4.2 mΩ/Ω + 0.1 MΩ 12 mΩ/Ω + 0.5 MΩ Multi- function calibrator Temperature Calibration, Indication, & Control Equipment Used With RTD – (Electrical Simulation)3 Cu 42 710 Ω PT 385 100 Ω PT 385 200 Ω PT 385 500 Ω PT 3 851 000 Ω PT 3 916 100 Ω PT 3 926 100 Ω PtNi 385 120 Ω (-100 to 260) °C (-200 to 630) °C (630 to 800) °C (-200 to 260) °C (260 to 630) °C (-200 to 260) °C (260 to 630) °C (-200 to 600) °C (600 to 630) °C (-200 to -190) °C (-190 to 600) °C (600 to 630) °C (-200 to 100) °C (100 to 630) °C (-80 to 100) °C (100 to 260) °C 0.31 °C 0.15 °C 0.25 °C 0.07 °C 0.17 °C 0.07 °C 0.12 °C 0.07 °C 0.24 °C 0.26 °C 0.11 °C 0.24 °C 0.08 °C 0.13 °C 0.09 °C 0.15 °C Multi- function calibrator
28

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 24 of 34 Parameter/Equipment Range CMC2, 6, 8 (±) Comments Temperature – Instruments (Electrical Simulation) – Thermocouple Devices3 Type B Type C Type E Type J Type K Type N Type R Type S Type T Type U (600 to 800) °C (800 to 1800) °C (0 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-200 to 0) °C (0 to 600) °C 0.41 °C 0.33 °C 0.25 °C 0.41 °C 0.66 °C 0.39 °C 0.13 °C 0.17 °C 0.21 °C 0.15 °C 0.19 °C 0.26 °C 0.15 °C 0.21 °C 0.32 °C 0.32 °C 0.18 °C 0.21 °C 0.30 °C 0.45 °C 0.29 °C 0.37 °C 0.49 °C 0.38 °C 0.32 °C 0.39 °C 0.49 °C 0.38 °C 0.31 °C 0.39 °C 0.44 °C 0.22 °C Multi-function calibrator
29--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 25 of 34 Parameter/Equipment Range CMC2, 6, 8 (±) Comments DC Current – Measure3 (1 to 100) μA 100 μA to 1 mA (1 to 100) mA (100 to 400) mA 400 mA to 1 A (1 to 3) A (3 to 10) A (10 to 1000) A 0.06 % + 0.06 µA 0.06 % + 0.6 µA 0.06 % + 6 µA 0.06 % + 24 µA 0.06 % + 28 µA 0.12 % + 2.4 mA 0.18 % + 4.4 mA 2.6 % Precision multimeter Clamp meter DC Voltage – Measure3 (0.01 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 20) kV (1 to 10) kV 0.004 % + 5µV 0.003 % + 13µV 0.003 % + 86µV 0.004 % + 0.94 mV 0.005 % + 14 mV 2.4 % 0.05 % Precision multimeter Multimeter & high voltage probe High voltage meter Capacitance – Measure3 Up to 1 nF (1 to 10) nF (10 to 100) nF 100 nF to 1 μF (1 to 10) μF (10 to 100) μF 100 µF to 1 mF (1 to 10) mF (10 to 100) mF 2.4 % + 0.034 nF 1.2 % + 0.09 nF 1.2 % + 0.65 nF 1.2 % + 7.4 nF 1.2 % + 73 nF 1.2 % + 0.77 μF 1.2 % + 7.8 µF 1.2 % + 78 µF 4.7 % + 1.30 mF Precision multimeter Resistance – Measure3 Equipment to Source Up to 10 Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ (100 to 1000) MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ (8 to 1200) Ω 0.012 % + 3.5 mΩ 0.012 % + 5.7 mΩ 0.012 % + 15 mΩ 0.012 % + 0.34 Ω 0.012 % + 0.36 Ω 0.012 % + 0.58 Ω 0.046 % + 0.79 kΩ 0.93 % + 0.14 MΩ 2.30 % + 0.14 MΩ 0.04 MΩ 0.26 MΩ 2 MΩ 0.19 GΩ 3.6 mΩ Precision multimeter Insulation resistance standard Transfer standard
to 1000 A
30--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 26 of 34 IV. Fluid Quantities Parameter/Equipment Range CMC2, 6 (±) Comments Liquid Flow Meter3 Up to 500 GPM 2 % Ultrasonic flow meter Liquid Flow Meter3 Rate Totalization Up to 30 GPM (31 to 200) GPM Up to 6 kg 0.16 % 0.13 % 0.11 % Coriolis flow meter Balance POVA (Piston/Plunger Operated Volumetric Apparatus)3 – Including But Not Limited To: Pipettes, Syringes, Dispensers, & Burettes (0.1 to 20) μL (20 to 200) μL (200 to 1000) μL (1000 to 10 000) μL (10 000 to 20 000) μL (10 to 100) mL 0.16 μL 0.22 μL 0.53 μL 5 μL 11 μL (0.58 % + 0.3) mL Micro balance Balance Graduated Cylinder/Flask/Beaker3 (50 to 6000) mL (0.98 % + 0.16) mL Balance Viscometers3 Up to 10 000 cP 1.7 % Viscosity reference standards
to 500 GPM
31ASTM Class 6-See scope document
32ASTM Class 1 mass-See scope document
33-Reference pressure gauges; Hardness test block masters
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 29 of 34 Parameter/Equipment Range CMC2, 6 (±) Comments Vacuum Gauge3 (-14 to -1) psi (-1 to 0) psi (-10 to -1) in H2O (-1 to 0) in H2O 0.009 psi 0.0024 psi 0.012 in H2O 0.0017 in H20 Reference pressure gauges Indirect Verification of Rockwell Hardness Testers3 HRC (20 to 35) HRC (35 to 59) HRC (60 to 70) HRC HRBW (40 to 59) HRB (60 to 87) HRB (88 to 99) HRB HRA (20 to 69) HRA (70 to 79) HRA (80 to 99) HRA HR15N (70 to 77) HR15N (78 to 89) HR15N (90 to 99) HR15N HR30N (40 to 54) HR30N (55 to 76) HR30N (77 to 90) HR30N HR15TW (65 to 80) HR15TW (81 to 86) HR15TW (87 to 99) HR15TW HR30TW (43 to 56) HR30TW (57 to 69) HR30TW (70 to 90) HR30TW 0.45 HRC 0.41 HRC 0.33 HRC 0.37 HRB 0.37 HRB 0.34 HRB 0.34 HRA 0.34 HRA 0.33 HRA 0.37 HR15N 0.34 HR15N 0.35 HR15N 0.37 HR30N 0.38 HR30N 0.35 HR30N 0.35 HR15TW 0.33 HR15TW 0.40 HR15TW 0.44 HR30TW 0.37 HR30TW 0.35 HR30TW Hardness test block masters
See scope document
34

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 30 of 34 Parameter/Equipment Range CMC2, 6 (±) Comments Knoop Hardness Testers HK (Indirect Verification)3 (250 to 650) HK (651 to 750) HK 10 HK 16 HK Hardness test block masters Vickers Hardness Testers HV (Indirect Verification)3 (240 to 600) HV (601 to 750) HV 10 HV 16 HV Hardness test block masters Brinell Hardness Testers HBW (Indirect Verification)3 (125 to 225) HBW >225 HBW 4.1 HBW 10 HBW Hardness test block masters, Brinell scope Torque Wrenches3 (4 to 40) ozf∙in (1 to 10) lbf∙in (2 to 20) lbf∙in (2.5 to 25) lbf∙in (1.5 to 29.5) lbf∙ft (5 to 50) lbf∙ft (25 to 250) lbf∙ft (22 to 1100) lbf∙ft (200 to 1000) lbf∙ft 0.7 % + 0.051 ozf∙in 0.7 % + 0.014 lbf∙in 0.7 % + 0.024 lbf∙in 0.7 % + 0.032 lbf∙in 0.7 % + 0.04 lbf∙ft 0.7 % + 0.07 lbf∙ft 0.7 % + 0.034 lbf∙ft 0.81 % + 0.4 lbf∙ft 0.82 % Torque transducers Rate of Rotation – Measurement Equipment 3 Contact Non-Contact (10 to 3800) RPM (5 to 999) RPM (1000 to 9999) RPM (10 000 to 99 999) RPM 0.05 % + 0.015 RPM 0.013 % + 0.0014 RPM 0.006 % + 0.008 RPM 0.003 % + 0.4 RPM Reference tachometer Reference strobe
35--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 31 of 34 Parameter/Equipment Range CMC2, 6 (±) Comments Rate of Rotation – Measure3 Length Non-Contact Up to 1000 FPM (6 to 8299) RPM (8300 to 24 999) RPM (25 000 to 90 000) RPM 0.21 % + 0.9 FPM 1.70 RPM 2.7 RPM 0.007 % + 1.5 RPM Reference tachometer w/wheel Reference tachometer VI. Optical Parameter/Equipment Range CMC2, (±) Comments Spectrophotometer3 – Photometric Accuracy Wavelength Accuracy (250 to 635) nm (240 to 640) nm 0.0044 AU 0.28 nm Neutral density filter holmium oxide filter
to 1000 FPM
36

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 32 of 34 VII. Thermodynamics Parameter/Equipment Range CMC2, 6, 7 (±) Comments Temperature Measuring Equipment – Infrared Thermometers3 (50 to 500) °C Fixed Points 50 °C 150 °C 250 °C 350 °C 500 °C 1.5 % + 0.9 °C 1.70 °C 3 °C 4.5 °C 5.6 °C 8.6 °C Black body calibrator Thermohygrometers – Humidity (%RH) 3 (20 to 90) % RH 2 % RH Reference thermohygrometer Thermohygrometers – Temperature3 (5 to 55) °C 0.15 °C Reference thermohygrometer Temperature – Measurement 3 (-200 to 0) °C (0 to 200) °C (200 to 420) °C (420 to 660) °C (-100 to 300) °C (300 to 1372) °C (-250 to 0) °C (0 to 400) °C (200 to 700) °C (700 to 1767) °C (50 to 500) °C 0.020 °C 0.033 °C 0.048 °C 0.065 °C 1.70 °C 3.20 °C 1.10 °C 0.76 °C 2.50 °C 3.80 °C 5.6 % + 0.3 °C PRT w/readout Portable calibrator, K thermocouple Portable calibrator, T thermocouple Portable calibrator, S thermocouple IR thermometer
37

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 33 of 34 Parameter/Equipment Range CMC2, 6, 7 (±) Comments Temperature – Measuring Equipment3 (-90 to 40) °C (40 to 300) °C (300 to 660) °C (660 to 1200) °C 0.025 °C 0.04 °C 0.065 °C 3.9 °C PRT w/readout Portable calibrator, S thermocouple VIII. Time & Frequency Parameter/Equipment Range CMC2, 6 7 (±) Comments Timers & Stopwatches3 (0.01 to 3600) s (3600 to 86 400) s 0.13 s 3.10 s Calibrated stopwatch Frequency – Source3 (0.1 to 119.99) Hz (120 to 1199.99) Hz (1.2 to 11.999) kHz (1.2 to 119.99) kHz (120 to 1199.9) kHz (1.2 to 2.000) MHz 0.004 Hz 0.025 Hz 0.24 Hz 2.4 Hz 24 Hz 40 Hz Multi-function calibrator Frequency – Measure3 (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40 Hz to 300 kHz 300 kHz to 1 MHz 0.13 % 0.07 % 0.04 % 0.02 % 0.04 % Precision multimeter __________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards of nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
38

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1509.03) 05/20/2025 Page 34 of 34 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is length measured in inches. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter 8 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 9 The uncertainties for scales and balances are highly dependent upon the resolution of the unit under test. The uncertainties presented here do not include the resolution of the unit under test. The resolution will be included in the reported measurement uncertainty at the time of calibration. 10 In the statement of CMC, H is the hardness value displayed in Durometer units.
39ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.