Ellab, Inc.
4030 Skyron Drive, Unit D, 18901, Doylestown, PA, United States
Visit website- Scope lines
- 13
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 13 scope lines.
A2LA certificate 4828.01 · 13 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 200 mV |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4828.01) Revised 2/20/2026 Page 2 of 12
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Current3 – Generate
Clamp On Only
Non Toroidal
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 3.1) A
(3.1 to 12) A
(12 to 30.2) A
(30.2 to 60) A
(60 to 1510) A
31 µA/A + 6 nA
27 µA/A + 7 nA
27 µA/A + 40 nA
35 µA/A + 0.7 µA
67 µA/A + 12 µA
230 µA/A + 150 µA
230 µA/A + 250 µA
780 µA/A + 500 µA
1.5 % + 0.5 A
0.55 % + 0.5 A
Fluke 5730A
Fluke 5560A
Fluke 5500A coil
& Fluke 5560A
DC Resistance3 – Measure
Up to 2 Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
15 µΩ/Ω + 8.1 µΩ
12 µΩ/Ω + 28 µΩ
9.0 µΩ/Ω + 100 µΩ
7.0 µΩ/Ω + 1.0 mΩ
7.0 µΩ/Ω + 10 mΩ
7.0 µΩ/Ω + 100 mΩ
11 µΩ/Ω + 20 Ω
23 µΩ/Ω + 200 Ω
43 µΩ/Ω+ 20 kΩ
580 µΩ/Ω + 2.0 MΩ
Fluke 8588A
Electrical Calibration of
RTDs3 – Simulation &
Measure
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.04 °C
0.05 °C
0.07 °C
0.08 °C
0.09 °C
0.18 °C
0.04 °C
0.05 °C
0.07 °C
0.08 °C
0.09 °C
0.19 °C
0.03 °C
0.04 °C
0.05 °C
0.05 °C
0.06 °C
0.07 °C
0.08 °C
0.18 °C
Fluke 5560A | to 1510 A |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4828.01) Revised 2/20/2026 Page 3 of 12
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Resistance3 – Generate
0 Ω
(0 to 1) Ω
(1 to 1.9) Ω
1.9 Ω to 10 Ω
(10 to 19) Ω
(19 to 100) Ω
(100 to 190) Ω
190 Ω to 1 kΩ
(1 to 1.9) kΩ
(1.9 to 10) kΩ
(10 to 19) kΩ
(19 to 100) kΩ
(100 to 190) kΩ
190 kΩ to 1.0ΜΩ
(1.0 to 1.9) MΩ
(1.9 to 10) MΩ
(10 to 19) MΩ
(19 to 100) MΩ
31 µΩ
74 µΩ
74 µΩ
20 µΩ
18 µΩ
8 µΩ
8 µΩ
5 µΩ
5 µΩ
5 µΩ
5 µΩ
9 µΩ
7 µΩ
12 µΩ
15 µΩ
40 µΩ
68 µΩ
180 µΩ
Fluke 5730A
Electrical Calibration of
Thermocouples3 –Simulation
& Measure
Type E
Type J
Type K
Type N
Type R
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
0.31 °C
0.11 °C
0.09 °C
0.12 °C
0.16 °C
0.19 °C
0.10 °C
0.09 °C
0.11 °C
0.16 °C
0.22 °C
0.13 °C
0.12 °C
0.16 °C
0.27 °C
0.26 °C
0.12 °C
0.09 °C
0.09 °C
0.16 °C
0.40 °C
0.23 °C
0.21 °C
0.26 °C
Fluke 5560A | to 100 MΩ |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4828.01) Revised 2/20/2026 Page 4 of 12
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples3 –
(cont)
Type S
Type T
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.33 °C
0.24 °C
0.25 °C
0.32 °C
0.47 °C
0.16 °C
0.10 °C
0.09 °C
Fluke 5560A
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Measure
Up to 12.12 mV,
Auto, 10 MΩ, 1 MΩ
(12.12 to 121.2) mV,
Auto, 10 MΩ, 1 MΩ
(0.121 to 1.212) V,
Auto, 10 MΩ, 1 MΩ
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
2200 µV/V + 1.3 µV
1000 µV/V + 1.3 µV
350 µV/V + 1.3 µV
0.3 % + 1.3 µV
1.0 % + 4.8 µV
2.0 % + 4.8 µV
3700 µV/V + 0.61 µV
3700µV/V + 0.61 µV
220 µV/V + 1.2 µV
520 µV/V + 6.1 µV
0.2 % + 36 µV
1.0 % + 120 µV
1.5 % + 610 µV
4.0 % + 1.2 mV
8.0 % + 1.2 mV
15 % + 1.2 mV
1900 µV/V + 6.1 µV
1900 µV/V + 6.1 µV
300 µV/V + 12 µV
600 µV/V + 61 µV
0.2 % + 370 µV
1.0 % + 1.3 mV
2.0 % + 6.0 mV
4.0 % + 12 mV
8.0 % + 12 mV
15 % + 12 mV
Fluke 8588A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4828.01) Revised 2/20/2026 Page 5 of 12
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Measure
(cont)
(1.212 to 12.12) V,
Auto, 10 MΩ, 1 MΩ
(12.12 to 121.2) V,
10 MΩ
(12.12 to 121.2) V,
Auto, 1 MΩ
(121.2 to 1050) V,
10 MΩ
(121.2 to 1050) V,
Auto, 1 MΩ
(1 to 2) kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(2 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
1 Hz to 1 kHz
(1 to 2) kHz
(2 to 10) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
1 Hz to 1 kHz
(1 to 2) kHz
(2 to 10) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1900 µV/V + 60 µV
1900 µV/V + 60 µV
300 µV/V + 120 µV
600 µV/V + 600 µV
0.2 % + 3.6 mV
1.0 % + 12 mV
2.0 % + 60 mV
4.0 % + 120 mV
8.0 % + 120 mV
15 % + 120 mV
1400 µV/V + 0.60 mV
1000 µV/V + 0.60 mV
2 % + 1.2 mV
160 µV/V + 0.6 mV
170 µV/V + 0.6 mV
230 µV/V + 1.2 mV
540 µV/V + 6.1 mV
170 µV/V + 61 mV
170 µV/V + 600 mV
830 µV/V + 11 mV
1000 µV/V + 11 mV
2 % + 11 mV
90 µV/V + 2.6 mV
90 µV/V + 2.6 mV
210 µV/V + 2.6 mV
510 µV/V + 110 mV
Fluke 8588A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4828.01) Revised 2/20/2026 Page 6 of 12
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Generate
(1 to 2.2) mV
(2.2 to 22) mV
22 to 220 mV
220 mV to 2.2 V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
190 µV/V + 7.0 µV
84 µV/V + 7.0 µV
71 µV/V + 6.0 µV
160 µV/V + 6.0 µV
460 µV/V + 15 µV
850 µV/V + 30 µV
1100 µV/V + 30 µV
3800 µV/V + 30 µV
180 µV/V + 4.0 µV
70 µV/V + 4.0 µV
62 µV/V + 4.0 µV
160 µV/V + 4.0 µV
400 µV/V + 5.0 µV
820 µV/V + 10 µV
1100 µV/V + 20 µV
2600 µV/V + 20 µV
190 µV/V + 12 µV
72 µV/V + 7.0 µV
48 µV/V + 7.0 µV
95 µV/V + 7.0 µV
250 µV/V + 17 µV
510 µV/V + 20 µV
1100 µV/V + 25 µV
2800 µV/V + 45 µV
190 µV/V + 40 µV
72 µV/V + 15 µV
36 µV/V + 8 µV
54 µV/V + 10 µV
79 µV/V + 30 µV
260 µV/V + 80 µV
780 µV/V + 200 µV
1400 µV/V + 300 µV
Fluke 5730A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4828.01) Revised 2/20/2026 Page 7 of 12
Parameter/Range
Frequency
CMC2, 5 (±) Comments
AC Voltage3 – Generate
(cont)
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(220 to 750) V
(750 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
15 Hz to 50 Hz
50 Hz to 1 kHz
(30 to 50) kHz
(50 to 100) kHz
(1 to 20) kHz
(20 to 30) kHz
190 µV/V + 400 µV
70 µV/V + 150 µV
33 µV/V + 50 µV
52 µV/V + 100 µV
64 µV/V + 200 µV
380 µV/V + 600 µV
840 µV/V + 2000 µV
3900 µV/V + 3200 µV
190 µV/V + 4.0 mV
72 µV/V + 1.5 mV
44 µV/V + 0.6 mV
64 µV/V + 1.0 mV
120 µV/V + 2.5 mV
700 µV/V + 16 mV
3400 µV/V + 40 mV
6200 µV/V + 80 mV
230 µV/V + 16 mV
60 µV/V + 3.5 mV
470 µV/V + 11 µV
1800 µV/V + 45 µV
130 µV/V + 6 µV
470 µV/V + 11 µV
Fluke 5730A
Fluke 5725A
Amplifier | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4828.01) Revised 2/20/2026 Page 8 of 12
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current3 – Measure
Up to 20.2 µA
(20.2 to 202) µA
(0.202 to 2.02) mA
(2.02 to 20.20) mA
(20.2 to 202) mA
(0.202 to 2.02) A
(2.02 to 20.2) A
(20.2 to 30.2) A
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
10 Hz to 2 kHz
(2 to 10) kHz
2100 µA/A + 5 nA
2100 µA/A + 5 nA
2100 µA/A + 5 nA
260 µA/A + 10 nA
510 µA/A + 0.1 µA
720 µA/A + 1 µA
4100 µA/A + 2 nA
260 µA/A + 0.1 µA
510 µA/A + 0.1µA
720 µA/A + 0.1µA
4100 µA/A + 0.2 µA
260 µA/A + 1 µA
510 µA/A + 1 µA
720 µA/A + 1 µA
4100 µA/A + 2 µA
260 µA/A + 10 µA
500 µA/A + 10 µA
710 µA/A + 10 µA
260 µA/A + 210 µA
510 µA/A + 210 µA
710 µA/A + 210 µA
810 µA/A + 1 mA
810 µA/A + 1 mA
800 µA/A + 130 mA
1200 µA/A + 130 mA
Fluke 8588A | to 30.2 A |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4828.01) Revised 2/20/2026 Page 9 of 12
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current3 – Generate
(22 to 220) µA
(.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
210 µA/A + 16 µA
140 µA/A + 10 µA
80 µA/A + 8 µA
220 µA/A + 12 µA
850 µA/A + 65 µA
190 µA/A + 40 µA
120 µA/A + 35 µA
80 µA/A + 35 µA
160 µA/A + 110 µA
850 µA/A + 650 µA
190 µA/A + 400 µA
120 µA/A + 350 µA
80 µA/A + 350 µA
160 µA/A + 550 µA
850 µA/A + 5000 µA
200 µA/A + 4 µA
130 µA/A + 3.5 µA
80 µA/A + 2.5 µA
160 µA/A + 3.5 µA
850 µA/A + 10 µA
190 µA/A + 35 µA
350 µA/A + 80 µA
5400 µA/A + 160 µA
360 µA/A + 35 µA
740 µA/A + 80 µA
2800 µA/A + 160 µA
Fluke 5730A
Fluke 5725A
Amplifier | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4828.01) Revised 2/20/2026 Page 10 of 12
Parameter/Range
Frequency
CMC2, 5 (±) Comments
AC Current3 – Generate
(cont)
(12 to 30.2) A
(30.2 to 60) A
(60 o 155) A
(155 to 600) A
(600 to 1510) A
(3 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
780 µA/A + 10 mA
540 µA/A + 8 mA
3900 µA/A + 8 mA
0.64 % output + 0.03 A
1.0 % output + 0.03 A
0.66 % output + 0.25 A
1.0 % output + 0.25 A
0.62 % output + 0.25 A
1.0 % output + 0.25 A
0.60 % output + 0.90 A
1.0 % output + 0.90 A
Fluke 5560A
Fluke 5500A coil &
Fluke 5560A
Capacitance3 – Generate
Up to 1.2 nF
(1.2 to 12) nF
(12 to 120) nF
120 nF to 1.2 µF
(1.2 to 12) µF
(12 to 120) µF
120 µF to 1.2 mF
(1.2 to 12) mF
(12 to 120) mF
0.23 % + 2 pF
0.24 % + 5 pF
0.09 % + 30 pF
0.08 % + 300 pF
0.09 % + 3 nF
0.09 % + 25 nF
0.15 % + 250 nF
0.15 % + 3 µF
0.30 % + 30 µF
Fluke 5560A
II. Fluid Quantities
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Piston Operated
Volumetric Apparatus
(2 to 10) µl
(10 to 50) µl
(50 to 200) µl
(200 to 1000) µl
0.058 µl
0.10 µl
0.26 µl
2.4 µl
Pipettes
Gravimetric method | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4828.01) Revised 2/20/2026 Page 11 of 12
III. Mechanical
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Pressure3 – Measuring
Equipment
(Up to 100) psia
(>100 to 300) psia
(>300 to 1000) psia
0.04 psia
0.14 psia
0.17 psia
Fluke PPC4
pressure module
Scales & Balances3
>100 mg to 20 g
(>20 to 250) g
>250 g to 1 kg
(>1 to 3) kg
(>3 to 10) kg
(>10 to 20) kg
(>20 to 24) kg
0.03 mg + 0.6R
0.11 mg + 0.6R
0.70 mg + 0.6R
2.0 mg + 0.6R
4.4 mg + 0.6R
16 mg + 0.6R
26 mg + 0.6R
Class 1 weights
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Humidity3 – Measuring
Equipment
(10 to 20) % RH
(>20 to 50) % RH
(>50 to 80) % RH
0.13 % RH + 0.6R
0.36 % RH + 0.6R
0.76 % RH + 0.6R
Thunder Scientific 2500
Humidity3 – Measure
(10 to 35) % RH
(35 to 50) % RH
(50 to 80) % RH
0.61 % RH
0.63 % RH
1.1 % RH
Rotronics HC2A-3
Temperature3 – Measure
-197 °C
(-197 to 0) °C
(0 to 231) °C
(231 to 420) °C
3 mK
2 mK
4.5 mK
6.4 mK
SPRT
Temperature – Measuring
Equipment3
(-90 to 140) °C
0.06 °C + 0.6R
SPRT, Fluke
Superthermometer
readout & dry block
Temperature – Measuring
Equipment
Tiple Point Water
Zinc
0.010 °C
419.527 °C
0.002 °C
0.0061 °C
Fluke Mini Fixed
Refrence Point Cells
Fluke Superthermometer
Readout | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4828.01) Revised 2/20/2026 Page 12 of 12
V. Time & Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Frequency3 – Measure
(1 to 350) MHz
1.2 µHz/Hz
Frequency counter
Keysight 53220A
Frequency3 – Measuring
Equipment
0.01 Hz to 2 MHz
3.3 µHz/Hz
Fluke 5560A
_________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a
laboratory can achieve within its scope of accreditation when performing more or less routine calibrations
of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and
Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level
of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific
calibration performed by the laboratory may be greater than the CMC due to the behavior of the
customer’s device and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of Calibration and Measurement Capability, R represents the numerical value of the
resolution of the device. In the statement of CMC, percentages are to be read as percent of reading, unless
otherwise noted. Percent “FS” represents percent of “Full Scale.”
5 The stated measure values are determined using the indicated instruments (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 13 | ISO/IEC 17025:2017; ANSI/NCSLI Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Laboratory TestingHatfield, PA · ~15 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Philadelphia, PALansdale, PA · ~15 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - AllentownAllentown, PA · ~43 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Constellation PowerlabsCoatesville, PA · ~69 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instru-Met CorporationUnion, NJ · ~80 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.