Registers refreshed 2026-11-20.See refresh dates
United States

DATASYST Engineering & Testing Services

S14 W33511 Highway 18, 53018, Delafield, WI, United States

Visit website
A2LA 2107.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
13
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 13 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60068 series7
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-28
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

ETSI3
ETSI EN 300 019-2-1
ETSI EN 300 019-2-2
ETSI EN 300 019-2-3
Other standards3
ASTM E1237
EN 10250
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

2107.01

The scope document we hold says it is valid until 2027-12-31.

View scope

Accredited scope, certificate 2107.01

LineMethodMatrixRange
1ETSI EN 300 019-2-2 v.2.1.2; ETSI EN 300 019-2-3 v.2.1.3; IEC 60068-2-6; IEC 60068-2-64; MIL-STD-202G Method 201A; MIL-STD-202G Method 204D; MIL-STD-202G Method 214; MIL-STD-810 (D, E, F, G, H) Method 514; MIL-STD-883E Method 2005.2; MIL-STD-883E Method 2007.2; MIL-STD-1344A Method 2005; RTCA/DO-160 G Section 8; SAE J1211 Section 4.7; SAE J1455 Section 4.10; GR-63-CORE Section 5.4.2; GR-63-CORE Section 5.4.3; GR-63-CORE Section 4.4.3; GR-63-CORE Section 5.3; IEC 60068-2-27; MIL-STD-202G Method 213B; MIL-STD-810 (D, E, F, G, H) Method 516; MIL-STD-810F Method 519; MIL-STD-883E Method 2002; MIL-STD-1344A Method 2004; RTCA/DO-160 G Section 7; SAE J1211 Section 4.8; SAE J1455 Section 4.11mechanical assemblies and electrical components-73 to 177 ºC
2CFR 49 Para. 178.603; ISO 16750-3; MIL-STD-1344A 2009; MIL-STD-1344A 2010; SAE J2527_201709; IEC 60068-2-1; MIL-STD-883E, Methods 1005; MIL-STD-883E, Methods 1006; MIL-STD-883E, Methods 1007; MIL-STD-883E, Methods 1008; MIL-STD-1344A Method 1005; MIL-STD-781; MIL-STD-810H Method 501; MIL-STD-810H Method 502; RTCA/DO-160 G Section 5; SAE J1211 Section 4.1; SAE J1455 Section 4.1; MIL-STD-810H Method 503; MIL-STD-883E Method 1010; MIL-STD-1344A Method1003; ETSI EN 300 019-2-1 v.2.1.2; IEC 60068-2-28; IEC 60068-2-30; MIL-STD-810H Method 507; IEC 60068-2-38; MIL-STD-202G Method 103B; MIL-STD-1344A Method 1002; SAE J1211 Section 4.2; SAE J1455 Section 4.2; RTCA/DO-160 G Section 6; ANSI/NEMA EN 10250-2024, Section 5.6; MIL-STD-810F, H Method 510; GR-63-CORE 5.1; MIL-STD-883E Method 1001, Condition B; MIL-STD-810H Method 500; RTCA DO 160 G Section 4; SAE J1211 Section 4.6; SAE J1455 Section 4.9; MIL-STD-810H (Method 505.7); MIL-STD-883E Method 1002; MIL-STD-810F, H Method 512; ANSI/NEMA EN 10250-2024, Section 5.7--73 to 177 ºC
3MIL-STD-1344A Method 1016; MIL-STD-810H Method 506; SAE J1211 Section 4.4; SAE J1455 Section 4.4; ISTA 1A; ISTA 1B; ISTA 1C; ISTA 1D; ISTA 1E; ISTA 1G; ISTA 2A; ISTA 2B; ISTA 2C; ISTA 3A; ISTA 3B; ISTA 3E; ISTA 3F; ISTA 4AB; ISTA 6 Series; Project 6-AMAZON.COM-SIOC; ISTA 7D; ASTM E1237; SAE J1455 4.13.1Packaged Products for Parcel Delivery SystemsSee scope document
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited DATASYST ENGINEERING & TESTING SERVICES, INC. Delafield, WI for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 22nd day of December 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2107.01 Valid to December 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

S14 W33511 Highway 18, Delafield, WI, 53018, US

43.05942, -88.40402

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.