SIMCO Electronics - Salt Lake City
65 E. Wadsworth Park Drive, Suite 101, 84020, Draper, UT, United States
Visit website- Scope lines
- 23
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 23 scope lines.
A2LA certificate 1395.20 · 23 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 2 of 22
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Height Masters
& Height Gages
Up to 24 in
(30 + 1.3L) µin
Gage blocks, amplifier,
surface plate
End Standards,
Micrometer Standards,
End Rods
Up to 12 in
(5.9 + 1.8L) µin
Pratt & Whitney
LabMaster
TM, gage blocks
Cylindrical Plug
Gages & Master Discs
Up to 12 in
(3.9 + 1.8L) µin
Pratt & Whitney
LabMaster
TM, gage blocks
Precision Balls &
Spheres
(0.01 to 3) in
(5.9 + 1.8L) µin
Pratt & Whitney
LabMaster
TM, gage blocks
Micrometers –
Flatness
Parallelism
Up to 40 in
Up to 1000 mm
Up to 1 in Diameter
Up to 0.001 in
(10 + 14L) µin + 0.6R
(0.23 + 14L) µm + 0.6R
7.3 µin
16 µin
Gage blocks
Optical flat
Optical parallel
Optical Flats
Up to 3 in Diameter
4.7 µin
3 in Van Keuren master
optical flat
Thread Plugs –
UN (60° threads)
UN
National Pipe (NPT)
Pitch Diameter:
Up to 12 in,
Pitch: (4 to 80) TPI
Pitch Diameter:
(1 to 300) mm,
Pitch: (0.3 to 4) mm
Major Diameter:
Up to 12 in
Pitch Diameter:
Up to 3 in Diameter,
Pitch: (8 to 27) TPI
Notch Height:
Up to 1.5 in
(70 + 4.2L) µin
(1.8 + 0.043L) µm
(27 + 4.2L) µin
(99 + 3.6L) µin
160 µin
Pratt & Whitney
SupermicrometerTM with:
thread wires (english)
Thread wires (metric)
Sine fixture & thread
wires (english)
Surface plate, gage blocks,
electronic indicator | to 24 in |
| 3 | Federal 832 (moody method) | - | to 40 in |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 4 of 22
II. Electrical – DC/Low Frequency
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current3 – Generate
(22 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.026 % + 16 nA
0.017 % + 10 nA
0.013 % + 8 nA
0.033 % + 12 nA
0.11 % + 8.4 µA
0.026 % + 54 nA
0.017 % + 51 nA
0.013 % + 51 nA
0.021 % + 0.12 µA
0.11 % + 0.65 µA
0.028 % + 0.40 µA
0.017 % + 0.35 µA
0.013 % + 0.35 µA
0.021 % + 0.55 µA
0.11 % + 5.0 µA
0.028 % + 4.0 µA
0.017 % + 3.5 µA
0.013 % + 2.5 µA
0.022 % + 3.5 µA
0.11 % + 10 µA
0.027 % + 35 µA
0.045 % + 80 µA
0.70 % + 0.16 mA
0.047 % + 0.17 mA
0.095 % + 0.38 mA
0.36 % + 0.75 mA
Fluke 57XXA/EP
calibrator w/5725A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 5 of 22
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current3 –
Generate (cont)
(11 to 20.5) A
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.11 % + 1.6 mA
0.11 % + 3.9 mA
2.3 % + 3.9 mA
Fluke 552XA
calibrator, LComp on
AC Current3 – Measure
(5 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 3) A
(3 to 30) A
(30 to 300) A
45 Hz to 1 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
(45 to 100) Hz
100 Hz to 5 kHz
45 Hz to 2 kHz
(2 to 10) kHz
(45 to 400) Hz
(45 to 400) Hz
0.072 % + 0.035 µA
0.070 % + 0.23 µA
0.037 % + 0.23 µA
0.070 % + 2.3 µA
0.037 % + 2.3 µA
0.070 % + 23 µA
0.037 % + 23 µA
0.093 % + 0.23 mA
0.12 % + 0.23 mA
1.0 % + 3 mA
2.0 % + 6 mA
1.0 % + 60 mA
1.0 % + 0.6 A
HP 3458A multimeter
GW Instek PCS-1000 | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 6 of 22
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 – Generate
(0.22 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
(0.22 to 2.2) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
0.04 % + 4.0 µV
0.081 % + 4.0 µV
0.032 % + 4.0 µV
0.033 % + 4.0 µV
0.06 % + 5.0 µV
0.13 % + 10 µV
0.22 % + 20 µV
0.37 % + 20 µV
0.027 % + 4.0 µV
0.013 % + 4.0 µV
0.010 % + 4.0 µV
0.021 % + 4.0 µV
0.051 % + 5.0 µV
0.11 % + 10 µV
0.14 % + 20 µV
0.30 % + 20 µV
0.024 % + 12 µV
97 µV/V + 7.5 µV
82 µV/V + 7.5 µV
0.020 % + 7.5 µV
0.047 % + 17 µV
0.091 % + 20 µV
0.14 % + 25 µV
0.28 % + 45 µV
0.025 % + 0.26 mV
91 µV/V + 0.26 mV
46 µV/V + 0.26 mV
77 µV/V + 0.26 mV
0.011 % + 0.26 mV
0.043 % + 0.27 mV
0.10 % + 0.33 mV
0.18 % + 0.40 mV
Fluke 57XXA/EP | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 7 of 22
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 (cont) –
Generate
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(15 to 50) Hz
50 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz*
(50 to 100) kHz *
0.024 % + 0.40 mV
92 µV/V + 0.15 mV
47 µV/V + 62 µV
76 µV/V + 0.11 mV
0.010 % + 0.20 mV
0.029 % + 0.60 mV
0.10 % + 2.0 mV
0.17 % + 3.2 mV
0.024 % + 4.8 mV
94 µV/V + 3.0 mV
56 µV/V + 2.6 mV
82 µV/V + 2.8 mV
0.016 % + 3.6 mV
0.090 % + 16 mV
0.44 % + 40 mV
0.80 % + 80 mV
0.030 % + 16 mV
74 µV/V + 4.3 mV
0.014 % + 6.0 mV
0.061 % + 6.0 mV
0.071 % + 11 mV
0.23 % + 45 mV
Fluke 57XXA/EP
w/5725A
*750V Maximum
AC Voltage3 – Measure
50 µV to 1 mV*
(1 to 10) mV
(10 to 100) mV
(0.3 to 3) MHz*
(3 to 10) MHz*
(10 to 20) MHz*
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 3) MHz*
(3 to 10) MHz*
(10 to 20) MHz*
(20 to 30) MHz*
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 3) MHz*
(3 to 10) MHz*
(10 to 20) MHz*
(20 to 30) MHz*
3.0 % + 8.0 µV
8.0 % + 10 µV
20 % + 10 µV
0.035 % + 3.5 µV
0.023 % + 1.3 µV
0.035 % + 1.3 µV
0.012 % + 1.3 µV
0.6 % + 1.3 µV
4.6 % + 2.3 µV
1.5 % + 8.0 µV
2.5 % + 10 µV
6 % + 10 µV
13 % + 14µV
89 µV/V + 4.6 µV
89 µV/V + 2.3 µV
0.017 % + 2.3 µV
0.035 % + 2.3 µV
0.093 % + 2.3 µV
0.35 % + 12 µV
1.2 % + 12 µV
1.5 % + 40 µV
2.5 % + 50 µV
6.0 % + 50 µV
13 % + 64 V
*R+S URE3
HP 3458A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 8 of 22
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 – Measure
(cont)
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 700) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 3) MHz*
(3 to 10) MHz*
(10 to 20) MHz*
(20 to 30) MHz*
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 3) MHz*
(3 to 10) MHz*
(10 to 20) MHz*
(20 to 30) MHz*
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
89 µV/V + 46 µV
89 µV/V + 23 µV
0.017 % + 23 µV
0.035 % + 23 µV
0.093 % + 23 µV
0.35 % + 0.12 mV
1.2 % + 0.12 mV
1.5 % + 0.60 mV
2.5 % + 0.60 mV
6.0 % + 0.90 mV
13 % + 1.2 mV
89 µV/V + 0.47 mV
89 µV/V + 0.23 mV
0.017 % + 0.23 mV
0.035 % + 0.23 mV
0.093 % + 0.23 mV
0.35 % + 1.2 mV
1.2 % + 1.2 mV
1.5 % + 3.0 mV
2.5 % + 7.0 mV
6.0 % + 9.0 mV
13 % + 9.0 mV
0.023 % + 4.6 mV
0.023 % + 2.3 mV
0.023 % + 2.3 mV
0.041 % + 2.3 mV
0.14 % + 2.3 mV
0.046 % + 47 mV
0.046 % + 24 mV
0.069 % + 23 mV
0.14 % + 23 mV
0.35 % + 23 mV
HP 3458A
*R+S URE3
AC Current – Clamp
Meters3
(0 to 500) A
(500 to 1000) A
(45 to 400) Hz
(45 to 400) Hz
0.37 % + 0.097 A
0.38 % + 0.2 A
Fluke 552XA &
5500A/COIL | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 9 of 22
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Current3 –
Generate
0 µA
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(2.2 to 11) A
(11 to 20.5) A
0.4 nA
42 µA/A + 6.2 nA
37 µA/A + 7.2 nA
37 µA/A + 40 nA
47 µA/A + 0.75 µA
84 µA/A + 12 µA*
0.036 % + 0.48mA
0.079 % + 0.65 mA
Reference open
Fluke 57XXA/EP w/
5725A
*add (±200 × I²) µA/A
for (>100 to 220) mA
& (±10 × I²) µA/A for
(>1 to 2.2) A
Fluke 552XA
DC Current – Clamp
Meters
3
(0 to 1000) A
0.37 % + 0.065 A
Fluke 552XA &
5500A/COIL
DC Current3 – Measure 0 A
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 3) A*
(3 to 30) A*
(30 to 300) A*
0.4 nA
26 µA/A + 1.1 nA
26 µA/A + 7.5 nA
27 µA/A + 75 nA
44 µA/A + 0.75 µA
0.013 % + 16 µA
0.030 % + 0.30 mA
0.030 % + 3.0 mA
0.060 % + 30 mA
Reference open
HP 3458A opt 002
*GW Instek PCS-1000I
DC Voltage3 –
Generate
0 V
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1000) V
27 nV
8.6 µV/V + 1.3 µV
5.2 µV/V + 1.4 µV
3.7 µV/V + 3.1 µV
3.7 µV/V + 4.9 µV
5.2 µV/V + 47 µV
6.9 µV/V + 0.43 mV
Reference short
Fluke 57XXA/EP
DC Voltage3 – Measure
0 V
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
27 nV
6.9 µV/V + 0.45 µV
5.4 µV/V + 0.46 µV
5.4 µV/V + 0.94 µV
8 µV/V + 45 µV
8 µV/V + 0.23 mV*
Reference short
HP 3458A opt 002
*Add 12 µV/V
(V
in/1000)2 for inputs
>100 V | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 10 of 22
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Resistance3 – Generate
Fixed Values
Variable
0 Ω
1.0 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1.0 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1.0 MΩ
1.9 MΩ
100 MΩ
19 MΩ
100 MΩ
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.33 to 1.1) GΩ
1.2 µΩ + 0.6R
98 µΩ/Ω
96 µΩ/Ω
26 µΩ/Ω
27 µΩ/Ω
11 µΩ/Ω
13 µΩ/Ω
9.2 µΩ/Ω
9.8 µΩ/Ω
9.0 µΩ/Ω
9.5 µΩ/Ω
12 µΩ/Ω
13 µΩ/Ω
21 µΩ/Ω
23 µΩ/Ω
45 µΩ/Ω
52 µΩ/Ω
0.011 %
32 µΩ/Ω + 0.78 mΩ
24 µΩ/Ω + 1.2 mΩ
22 µΩ/Ω + 1.1 mΩ
22 µΩ/Ω + 1.6 mΩ
22 µΩ/Ω + 1.6 mΩ
22 µΩ/Ω + 16 mΩ
22 µΩ/Ω + 16 mΩ
22 µΩ/Ω + 0.16 Ω
22 µΩ/Ω + 0.16 Ω
28 µΩ/Ω + 1.6 Ω
28 µΩ/Ω + 1.6 Ω
52 µΩ/Ω + 24 Ω
0.011 % + 40 Ω
0.021 % + 2 kΩ
0.041 % + 2.7 kΩ
0.24 % + 80 kΩ
1.2 % + 0.39 MΩ
Reference short
Fluke 57XXA/EP
Fluke 552XA | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 11 of 22
Parameter/Equipment
Range
CMC2, 4, 7 (±)
Comments
Resistance3 – Measure
0 Ω
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1.0) GΩ
1.2 µΩ + 0.6R
19 µΩ/Ω + 85 µΩ
16 µΩ/Ω + 0.82 mΩ
14 µΩ/Ω + 0.82 mΩ
14 µΩ/Ω + 8.2 mΩ
14 µΩ/Ω + 83 mΩ
20 µΩ/Ω + 2.7 Ω
62 µΩ/Ω + 0.12 kΩ
0.059 % + 3.7 kΩ
0.6 % + 0.26 MΩ
Reference short
HP 3458A
Capacitance – Generate
(0.19 to 0.3999) nF
(0.4 to 1.039 99) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
0.44 % + 8.1 pF
0.39 % + 8.1 pF
0.39 % + 8.1 pF
0.20 % + 8.1 pF
0.20 % + 78 pF
0.20 % + 80 pF
0.20 % + 0.23 nF
0.20 % + 0.78 nF
0.20 % + 2.3 nF
0.20 % + 23 nF
0.31 % + 23 nF
0.35 % + 78 nF
0.35 % + 0.23 µF
0.35 % + 0.78 µF
0.35 % + 2.3 µF
0.35 % + 7.8 µF
0.60 % + 23 µF
0.85 % + 78 µF
Fluke 552XA | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 12 of 22
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples3 –
Type E
Type J
Type K
Type N
Type R/S
Type T
(-270 to -200) °C
(-200 to 0) °C
(0 to 600) °C
(600 to 1000) °C
(-210 to -100) °C
(-100 to 900) °C
(900 to 1200) °C
(-270 to -200) °C
(-200 to -100) °C
(-100 to 600) °C
(600 to 1000) °C
(1000 to 1372) °C
(-270 to -200) °C
(-200 to 0) °C
(0 to 1300) °C
(-50 to 0 °C
(0 to 500) °C
(500 to 1768) °C
(-270 to -200) °C
(-200 to 0) °C
(0 to 400) °C
0.091 °C
0.049 °C
0.041 °C
0.044 °C
0.056 °C
0.050 °C
0.054 °C
0.15 °C
0.068 °C
0.053 °C
0.060 °C
0.069 °C
0.23 °C
0.094 °C
0.070 °C
0.35 °C
0.29 °C
0.28 °C
0.13 °C
0.068 °C
0.049 °C
Fluke 552XA Vdc
output mode with
external
thermocouple
reference probe | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 13 of 22
Parameter/Equipment
Range
CMC2, 5, 7 (±)
Comments
Oscilloscopes3 –
DC Signal
Square Wave
Leveled Sine Wave:
5 mV to 5 V
5 mV to 2 V
Edge Transition
Timing Marker
Functions
Pulse Width
± 1 mV to ± 200 V
dc
(into 50 Ω)
± 1 mV to ± 50 Vdc
(into 1 MΩ)
40 μV to <1 mV
pk-pk
1 mV to 200 Vpk-pk
50 kHz Reference
Amplitude
0.1 Hz to 300 MHz
(>300 to 550) MHz
(>0.55 to 2.5) GHz
(>2.5 to 3.0) GHz
(>3.0 to 6.5) GHz
500 ps,
(10 Hz to 2 MHz rate)
150 ps,
(10 Hz to 2 MHz rate)
70 ps,
(10 Hz to 1 MHz rate)
9.0091 ns to <83 μs
≥83 μs to 55 s
(1 to 100) ns
0.061 % + 25 μV
0.83 % + 10 μV
0.16 % + 10 μV
1.2 %
2.2 %
2.5 %
2.8 %
2.8 %
3.5 %
33 ps
14 ps
8 ps
0.2 μs/s
2.3 μs/s
4.1 % + 200 ps
Fluke 9500B
Oscilloscope
calibrator with
9530/9560 active
heads | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 14 of 22
III. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
Amplitude Modulation –
Measure
Rate: 50 Hz to 10 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 10 kHz
Depth: to 99 %
Rate: 50 Hz to 50 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depth: to 99 %
Rate: 50 Hz to 50 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depth: to 99 %
150 kHz to 10 MHz
150 kHz to 10 MHz
>10 MHz to 1.3 GHz
>10 MHz to 1.3 GHz
(>1.3 to 26.5) GHz
(>1.3 to 26.5) GHz
2.1 % + 1 digit
3 % + 1 digit
1.1 % + 1 digit
3 % + 1 digit
1.6 % + 1 digit
3 % + 1 digit
HP 8902A
measuring receiver
with 11722/92A
sensors & 11793A
mixer
Frequency Modulation –
Measure
Rate: 20 Hz to 10 kHz
Dev: <40 kHz/pk
Rate: 50 Hz to 100 kHz
Dev: <400 kHz/pk
Rate: 20 Hz to 200 kHz
Dev: <400 kHz/pk
250 kHz, 10 MHz
10 MHz to 26.5 GHz
10 MHz to 26.5 GHz
2 % + 1 digit
1.1 % + 1 digit
5 % + 1 digit
HP 8902A
measuring receiver
Frequency Response
(Flatness)
(0.1 to 20) MHz @ 1 Vrms
(>20 to 50) MHz @ 1 Vrms
(>50 to 100) MHz @ 1 Vrms
(0.1 to 20) MHz @ 3 Vrms
(>20 to 50) MHz @ 3 Vrms
(>50 to 100) MHz @ 3 Vrms
0.16 %
0.61 %
1.8 %
0.48 %
0.75 %
1.4 %
Thermal converters
& DMM | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 15 of 22
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
RF Attenuation – Measure
(0 to 10) dB
(>10 to 20) dB
(>20 to 30) dB
(>30 to 40) dB
(>40 to 50) dB
(>50 to 60) dB
(>60 to 70) dB
(>70 to 80) dB
(>80 to 90) dB
(>90 to 100) dB
(>100 to 110) dB
(0 to 10) dB
(>10 to 20) dB
(>20 to 30) dB
(>30 to 40) dB
(>40 to 50) dB
(>50 to 60) dB
(>60 to 70) dB
(>70 to 80) dB
(>80 to 90) dB
(>90 to 100) dB
(>100 to 110) dB
(0 to 10) dB
(>10 to 20) dB
(>20 to 30) dB
(>30 to 40) dB
(>40 to 50) dB
(>50 to 60) dB
(>60 to 70) dB
(>70 to 80) dB
(>80 to 90) dB
(>90 to 100) dB
(>100 to 110) dB
0.1 MHz to 1.3 GHz
(>1.3 to 18) GHz
(>18 to 26.5) GHz
0.064 dB
0.068 dB
0.079 dB
0.079 dB
0.095 dB
0.12 dB
0.14 dB
0.16 dB
0.20 dB
0.22 dB
0.33 dB
0.078 dB
0.083 dB
0.093 dB
0.1 dB
0.13 dB
0.15 dB
0.17 dB
0.2 dB
0.23 dB
0.33 dB
0.34 dB
0.095 dB
0.097 dB
0.1 dB
0.12 dB
0.14 dB
0.16 dB
0.17 dB
0.21 dB
0.23 dB
0.32 dB
0.34 dB
HP 8902A measuring
receiver with 11722A
sensor
HP 8902A measuring
receiver with 11792A
sensor | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 16 of 22
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
Absolute RF Power –
Measure
1 µW to 100 mW*
(-30 to +20 dBm)
100 pW to 1.0 µW
(-70 to -30 dBm)
0 dBm at 50 MHz
(100 to 300) kHz
>300 kHz to 1 MHz
>1 MHz to 2 GHz
(>2 to 12.4) GHz
(>12.4 to 18) GHz
(>18 to 26.5) GHz
(>26.5 to 40) GHz
(>40 to 50) GHz
(0.05 to 0.1) GHz
(0.1 to 2) GHz
(>2 to 12.4) GHz
(>12.4 to 18) GHz
(>18 to 34) GHz
(>34 to 40) GHz
(>40 to 50) GHz
0.6 %
1.7 % + 140 nW
1.2 % + 140 nW
1.2 % + 140 nW
1.6 % + 140 nW
2.3 % + 140 nW
2.4 % + 140 nW
2.8 % + 140 nW
4.1 % + 140 nW
2.5 % + 57 pW
1.9 % + 57 pW
1.8 % + 57 pW
2.1 % + 57 pW
2.9 % + 57 pW
3.4 % + 57 pW
5.4 % + 57 pW
Power meter &
thermistor with DC
substitution
8480-series power
sensors & EPM-series
meter, *add 1.9 % to
CMC for sensor
linearity at levels
greater than 10 mW
(+10 dBm)
8487D power sensor &
EPM-series meter | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 17 of 22
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
Tuned RF Power –
Measure
100 kHz to 1.3 GHz
(>1.3 to 18) GHz
(>18 to 26.5) GHz
(+10 to 0) dBm
(<0 to -10) dBm
(<-10 to -20) dBm
(<-20 to -30) dBm
(<-30 to -40) dBm
(<-40 to -50) dBm
(<-50 to -60) dBm
(<-60 to -70) dBm
(<-70 to -80) dBm
(<-80 to -90) dBm
(<-90 to -100) dBm
(<-100 to -110) dBm
(<-110 to -120) dBm
(+10 to 0) dBm
(<0 to -10) dBm
(<-10 to -20) dBm
(<-20 to -30) dBm
(<-30 to -40) dBm
(<-40 to -50) dBm
(<-50 to -60) dBm
(<-60 to -70) dBm
(<-70 to -80) dBm
(<-80 to -90) dBm
(<-90 to -100) dBm
(<-100 to -110) dBm
(<-110 to -120) dBm
(+10 to 0) dBm
(<0 to -10) dBm
(<-10 to -20) dBm
(<-20 to -30) dBm
(<-30 to -40) dBm
(<-40 to -50) dBm
(<-50 to -60) dBm
(<-60 to -70) dBm
(<-70 to -80) dBm
(<-80 to -90) dBm
(<-90 to -100) dBm
(<-100 to -110) dBm
(<-110 to -120) dBm
2.5 %
2.5 %
2.7 %
3.2 %
3.5 %
3.8 %
4.2 %
5 %
5.4 %
5.9 %
6.4 %
6.9 %
13 %
2.5 %
2.6 %
2.7 %
3 %
3.4 %
3.8 %
4.2 %
5 %
5.4 %
5.9 %
6.4 %
6.9 %
13 %
2.5 %
2.5 %
2.7 %
2.9 %
3.4 %
3.8 %
4.2 %
5 %
5.4 %
5.9 %
6.3 %
6.9 %
13 %
HP 8902A
measuring receiver
with 11722A sensor
HP 8902A
measuring receiver
with 11792A sensor | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 18 of 22
Parameter/Range
Frequency
CMC2, 5, 7 (±)
Comments
Phase Modulation –
Measure
Rate: 200 Hz to 10 kHz
Rate: 20 Hz to 200 kHz
150 kHz to 10 MHz
10 MHz to 26.5 GHz
4 % + 0.015 rad
5 % + 0.019 rad
HP 8902A
measuring receiver
w/ HP 11792A
sensor
Harmonic Distortion –
Measure
(-80 to 0) dB
(-65 to 0) dB
(-117 to 0) dB
20 Hz to 20 kHz
(20 to 100) kHz
9 kHz to 1.3 GHz
(1.3 to 22) GHz
(>22 to 50) GHz
1.0 dB
2.0 dB
3.1 dB
3.5 dB
3.9 dB
HP 8903A audio
analyzer
HP 8565E spectrum
analyzer
IV. Mechanical
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Durometers –
Indenter Geometry:
Diameter
Angle8
Extension
Force Calibration:
Type A, B, E, O
Type C, D, DO
Up to 0.010 in
(0.010 to 0.50) in
(29 to 36) degrees
Up to 0.1 in
(56 to 821) gf
(0 to 4.6) kgf
(150 + 21L) µin
(110 + 21L) µin
290 arc sec
(140 + 30L) µin
1.9 gf
11 gf
Starrett optical
comparator
Mettler-Toledo
precision
balance | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 19 of 22
Parameter/Equipment
Range
CMC2, 4, 5, 10 (±)
Comments
Mass
1 mg to 40 g
(>40 to 200) g
>200 g to 6 kg
(>6 to 32) kg
0.048 mg
0.16 mg
12 mg
0.12 g
Class S weights,
analytical
balances
Scales & Balances3
(1 to 50) mg
(>50 to 500) mg
>500 mg to 5 g
(>5 to 20) g
>20 g to 30 kg
(5 to 700) lb
0.025 mg + 0.6R
0.033 mg + 0.6R
0.058 mg + 0.6R
0.078 mg + 0.6R
3.1 µg/g + 0.6R
0.01 % + 0.6R
Class S weights
Class F weights
Force – Measuring
Equipment
Compression &
Tension
10 gf to 320 kgf
(0.002 to 700) lbf
0.05 % + 0.6R
0.05 % + 0.6R
Class F weights
Pneumatic Pressure –
Measuring Equipment
Dry Nitrogen Gas
(0 to 90) psi(a)
(90 to 300) psi(a)
(0 to 90) psi(g)
(90 to 300 psi(g)
(300 to 1000) psi(a)
0.0021 % + 0.009 psi + 0.6R
0.01 % + 0.000 64 psi + 0.6R
0.0021 % + 0.009 psi + 0.6R
0.01 % + 0.000 64 psi + 0.6R
0.01 % of IV + 0.6R
Additel 780S
Controller,
ADT160A-RD-
AP300Q
Module
Additel 780S
Controller,
ADT160A-RD-
AP1KQ Module | ||
| 20 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 20 of 22
Parameter/Equipment
Range
CMC2, 4, 5, 10 (±)
Comments
Vacuum
(-12.5 to 0) psi(g)
0.0021 % + 0.009 psig +
0.6R
Additel 780S
controller,
ADT160A-RD-
AP300Q Module
Torque Handtools –
Measuring Equipment
3
10 ozf·in to 1000 lbf·ft
1.0 % + 0.6R
Digital torque load
cells
Torque Measurement
Devices – Generate
10 ozf·in to 1000 lbf·ft
0.06 %
Calibration arms &
weights
V. Thermodynamics
Parameter/Equipment
Range
CMC2, 4, 10 (±)
Comments
Temperature3 –
Measure
(-180 to 650) °C
(650 to 1000) °C
0.014 °C + 0.6R
0.63 °C + 0.6R
SPRT, super
thermometer
Type S
thermocouple
Temperature3 –
Measuring Equipment
(-40 to 120) °C
(120 to 650) °C
(650 to 1000) °C
0.014 °C + 0.6R
0.22 °C + 0.6R
0.70 °C + 0.6R
SPRT super
thermometer with:
Bath
Drywell
Type S
thermocouple &
Fluke Blackstack | -12.5 to 0 psi(g) |
| 21 | NIST SP 960-12 | - | to 24 hr |
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1395.20) Revised 04/16/2025 Page 22 of 22
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibratio n and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 Unless otherwise noted, in the statement of CMC Uncertainty, L is the numerical value of the nominal
length of the device measured in inches. In the statement of CMC Uncertainty, R is the numerical value
of the resolution of the device in microinches. In the statement of CMC Uncertainty, IV represents
indicated value.
5 In the statement of CMC, the value is defined as the percentage of reading unless otherwise noted.
6
D = Largest Diameter or Diagonal, as applicable to Surface Plate shape.
7 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
8 Angular measurements using geometric construction of 2-lines measured by motion.
9 This scope meets A2LA’s P112 Flexible Scope Policy.
10 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
11 Repeatability of the Unit Under Test has not been utilized in the calculation of the CMC value for this
measurement parameter. | ||
| 23 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Western States CalibrationSalt Lake City, UT · ~26 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Sensor CalibrationsKaysville, UT · ~57 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - DenverLongmont, CO · ~574 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- BHD Test & MeasurementThornton, CO · ~589 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Colorado Engineering Experiment Station,Nunn, CO · ~598 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.