Trescal, Inc - Tampa, FL

5455 W Waters Avenue, Suite 210, 33634, Tampa, FL, United States

Visit website
A2LA 1078.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
20
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 20 scope lines.

A2LA certificate 1078.02 · 20 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 2 of 19 Parameter/Equipment Range CMC2 (±) Comments Cylindrical Plugs / Pins Up to 1 in 27 µin + 5.4 µin/in Laser mic w/ master pins Height Gages3 Up to 48 in 13 µin + 5.3 µin/in Gage blocks Indicators3 Up to 4 in 6.5 µin + 3.2 µin/in Gage blocks Micrometers – Depth, Inside, Outside Groove Up to 80 in Up to 4 in 8.3 µin + 4.8 µin/in 8.3 µin + 4.9 µin/in Gage blocks Flatness Up to 1 in diameter 5.5 µin Optical flat Protractors3 Digital & Bevel (0 to 90)° 0.085° Sine bar, gage blocks, cylindrical square, surface plate Surface Plate3 – Flatness Repeatability Up to 100 in diagonal Up to 0.001 in √DL x 12 µin 31 µin Level meters (DL is the diagonal in inches) Repeat-o-meter
to 1 in
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 3 of 19 III. Electrical – DC/Low Frequency Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate3 (29 to 329.99) µA 330 µA to 3.2999 mA (3.3 to 32.999) mA (33 to 329.99) mA 330 mA to 1.099 99 A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.13 µA + 1.6 nA/µA 0.12 µA + 1.2 nA/µA 0.11 µA + 1 nA/µA 0.19 µA + 2.4 nA/µA 0.35 µA + 6.4 nA/µA 0.70 µA + 13 nA/µA 0.65 µA + 1.6 µA/mA 0.45 µA + 1 µA/mA 0.39 µA + 0.8 µA/mA 0.69 µA + 1.6 µA/mA 2.9 µA + 1.6 µA/mA 3.4 µA + 8 µA/mA 6.4 µA + 1.4 µA/mA 4 µA + 0.72 µA/mA 2.7 µA + 0.32 µA/mA 3.7 µA + 0.64 µA/mA 7.7 + 1.6 µA/mA 14 µA + 3.2 µA/mA 65 µA + 1.4 µA/mA 42 µA + 0.72 µA/mA 29 µA + 0.31 µA/mA 68 µA + 0.8 µA/mA 0.13 mA + 1.6 µA/mA 0.27 mA + 3.2 µA/mA 0.56 mA + 1.4 mA/A 0.22 mA + 0.4 mA/A 2.4 mA + 4.8 mA/A 11 mA + 20 mA/A 1.7 mA + 1.4 mA/A 0.61 mA + 0.48 mA/A 6.1 mA + 4.8 mA/A 26 mA + 20 mA/A 3.1 mA + 0.48 mA/A 4 mA + 0.8 mA/A 74 mA + 24 mA/A 15 mA + 0.96 mA/A 17 mA + 1.2 mA/A 0.27 A + 24 mA/A Fluke 5520A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 4 of 19 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Current – Generate3 Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A Nontoroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (20 to 120) A (120 to 3000) A (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (45 to 65) Hz 26 mA + 2.1 mA/A 50 mA + 1.9 mA/A 0.34 A + 1.9 mA/A 60 mA + 6 mA/A 0.11 A + 5.3 mA/A 0.86 A + 5.3 mA/A 60 mA + 3.8 mA/A 0.23 A + 3.7 mA/A 1.2 A + 3.7 mA/A 90 mA + 7.2 mA/A 0.28 A + 6.7 mA/A 1.6 A + 6.7 mA/A 0.16 % 0.13 % Fluke 5520A w/ 5500A coil 5520A, 3458A, amplifier & shunt 5520A, amplifier, Shunt, 3458A w/3KA coil AC Current – Measure3 (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz 58 nA + 4 mA/A 45 nA + 1.5 mA/A 41 nA + 0.64 mA/A 0.43 µA + 0.0041 mA/mA 0.31 µA + 0.0016 mA/mA 0.26 µA + 0.000 67 mA/mA 0.25 µA + 0.000 37 mA/mA 0.26 µA + 0.000 67 mA/mA 0.63 µA + 0.0042 mA/mA 1.8 µA + 0.0056 mA/mA 2.4 µA + 0.0041 mA/mA 2.3 µA + 0.0016 mA/mA 2.3 µA + 0.000 67 mA/mA 2.3 µA + 0.000 37 mA/mA 2.3 µA + 0.000 67 mA/mA 4.5 µA + 0.0041 mA/mA 16 µA + 0.0056 mA/mA HP 3458A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 5 of 19 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Measure3 (cont) (10 to 100) mA (0.1 to 1) A (1 to 3) A (3 to 10) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz 10 Hz to 5 kHz (5 to 10) kHz 10 Hz to 5 kHz (5 to 10) kHz 42 µA + 0.004 mA/mA 30 µA + 0.0015 mA/mA 25 µA + 0.0006 mA/mA 24 µA + 0.0003 mA/mA 25 µA + 0.0006 mA/mA 62 µA + 0.004 mA/mA 0.18 mA + 0.0055 mA/mA 0.42 mA + 0.0041 A/A 0.3 mA + 0.0017 A/A 0.26 mA + 0.0009 A/A 0.27 mA + 0.0011 A/A 0.37 mA + 0.0031 A/A 0.92 mA + 0.01 A/A 2.9 mA + 1.1 mA/A 20 mA + 2.7 mA/A 12 mA + 0.9 mA/A 63 mA + 2.7 mA/A HP 3458A Fluke 8845A AC High Voltage – Measure3 (1 to 10) kV (10 to 50) kV 50/60/400 Hz 1.6 V + 1.4 mV/V 14 V + 1.2 mV/V Vitrek 4700 w/HVL-70 probe Parameter/Equipment Range CMC2, 4, 5 (±) Comments AC Power – Generate3 (45 to 65) Hz, PF = 1 Up to 32.999 mA (33 to 329.999) mA (0.33 to 1.099 99) A (1.1 to 2.9999) A (3 to 10.999 99) A (11 to 20.5) A Up to 1020 V Up to 33 W (33 to 330) W 330 W to 1.1 kW (1.1 to 3) kW (3 to 11) kW (11 to 20.9) kW 0.1 % 0.062 % 0.072 % 0.075 % 0.087 % 0.14 % Fluke 5520A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 6 of 19 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Flatness – Measure3 10 Hz to 1 MHz (1 to 20) MHz (20 to 30) MHz (30 to 50) MHz (50 to 70) MHz (70 to 80) MHz (80 to 100) MHZ 0.039 % 0.074 % 0.1 % 0.25 % 0.5 % 0.63 % 0.93 % EL1100 TVC AC Voltage – Generate3 (1 to 33) mV (33 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 200) kHz (200 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 200) kHz (200 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 200) kHz (200 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 5.5 µV + 0.64 µV/mV 5 µV + 0.12 µV/mV 5 µV + 0.16 µV/mV 5.6 µV + 0.8 µV/mV 12 µV + 2.8 µV/mV 47 µV + 6.4 µV/mV 47 µV + 6.4 µV/mV 14 µV + 0.24 µV/mV 24 µV + 87 nV/mV 11 µV + 0.13 µV/mV 35 µV + 0.28 µV/mV 47 µV + 0.64 µV/mV 0.11 mV + 1.6 µV/mV 0.11 mV + 1.6 µV/mV 0.12 mV + 0.24 mV/V 88 µV + 0.12 mV/V 99 µV + 0.15 mV/V 0.12 mV + 0.24 mV/V 0.29 mV + 0.56 mV/V 1.1 mV + 1.9 mV/V 1.1 mV + 1.9 mV/V 1.3 mV + 0.24 mV/V 0.94 mV + 0.12 mV/V 1.6 mV + 0.18 mV/V 1.4 mV + 0.28 mV/V 3.7 mV + 0.72 mV/V 6.8 mV + 0.15 mV/V 10 mV + 0.16 mV/V 12 mV + 0.2 mV/V 13 mV + 0.24 mV/V 93 mV + 1.6 mV/V 87 mV + 0.24 mV/V 74 mV + 0.2 mV/V 88 mV + 0.24 mV/V Fluke 5520A
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 7 of 19 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure Up to 100 mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 6.1 µV + 0.0003 mV/mV 4.1 µV + 0.0002 mV/mV 4.2 µV + 0.0003 mV/mV 4.9 µV + 0.001 mV/mV 9 µV + 0.005 mV/mV 45 µV + 0.04 mV/mV 12 µV + 0.000 07 mV/mV 2.7 µV + 0.000 07 mV/mV 11 µV + 0.000 14 mV/mV 12 µV + 0.0003 mV/mV 17 µV + 0.0008 mV/mV 47 µV mV + 0.003 mV/mV 0.12 mV + 0.01 mV/mV 3.8 mV + 0.01 mV/mV 0.12 mV + 0.000 07 V/V 0.1 mV + 0.000 07 V/V 0.11 mV + 0.000 14 V/V 0.12 mV + 0.0003 V/V 0.17 mV + 0.0008 V/V 0.47 mV + 0.003 V/V 1.2 mV + 0.010 V/V 38 mV + 0.015 V/V 1.2 mV + 0.000 07 V/V 1 mV + 0.000 07 V/V 1 mV + 0.000 14 V/V 1.2 mV + 0.0003 V/V 1.7 mV + 0.0008 V/V 4.7 mV + 0.003 V/V 12 mV + 0.01 V/V 0.38 V + 0.015 V/V 13 mV + 0.0002 V/V 11 mV + 0.0002 V/V 11 mV + 0.0002 V/V 13 mV + 0.000 35 V/V 21 mV + 0.0012 V/V 57 mV + 0.004 V/V 0.17 V + 0.015 V/V Agilent 3458A
to 1000 V
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 8 of 19 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) μF (1.1 to 3.299 99) μF (3.3 to 10.9999) μF (11 to 32.9999) μF (33 to 109.999) μF (110 to 329.999) μF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 8.8 pF + 4 pF/nF 9.7 pF + 4 pF/nF 13 pF + 4 pF/nF 15 pF + 2 pF/nF 0.1 nF + 2 pF/nF 0.15 nF + 2 pF/nF 0.46 nF + 2 pF/nF 1.5 nF + 2 nF/µF 4.6 nF + 2 nF/µF 15 nF + 2 nF/µF 59 nF + 3.2 nF/µF 0.2 µF + 3.6 nF/µF 0.64 µF + 3.6 nF/µF 2 µF + 3.6 µF/mF 7 µF + 3.5 µF/mF 38 µF + 2.6 µF/mF 90 µF + 6 µF/mF 0.37 mF + 8.8 µF/mF Fluke 5520A Capacitance – Generate, Fixed Points3 1 nF 2 nF 10 nF 20 nF 500 nF 1 µF 100 Hz 1 kHz 100 Hz 1 kHz 100 Hz 1 kHz 100 Hz 1 kHz 100 Hz 1 kHz 100 Hz 1 kHz 0.042 % 0.024 % 0.015 % 0.024 % 0.042 % 0.024 % 0.042 % 0.024 % 0.042 % 0.024 % 0.042 % 0.024 % GenRad 1409 & 509 standard capacitors
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 9 of 19 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Inductance – Generate, Fixed Points3 100 µH 500 µH 1 mH 5 mH 50 mH 500 mH 1 H 100 Hz to 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz to 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz to 1 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 0.052 % 0.053 % 0.62 % 0.32 % 0.11 % 0.03 % 0.5 % 0.052 % 0.053 % 0.071 % 0.042 % 0.033 % 0.024 % 0.5 % 0.042 % 0.042 % 0.033 % 0.024 % 0.5 % 0.052 % 0.042 % 0.042 % 0.034 % 0.025 % 0.17 % GenRad 1482 standard inductors Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Current – Generate3 (0 to 329.999) µ A 330 µA to 3.299 99 mA (3.3 to 32.9999) mA (33 to 329.999) mA 330 mA to 1.099 99 A (1.1 to 2.999 99) A (3 to 10.9999) A (11 to 20.5) A (20 to 120) A 16 nA + 0.12 nA/µA 41 nA + 80 nA/mA 0.21 µA + 80 nA/mA 2.1 µA + 80 nA/mA 33 µA + 0.16 mA/A 0.37 mA + 0.13 mA/A 0.49 mA + 0.39 mA/A 9.4 mA + 0.8 mA/A 0.024 % Fluke 5520A 5520A, 3458A amplifier w/shunt
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 10 of 19 Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Current – Generate3 (cont) Clamp Meters (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (120 to 3000) A 50 mA + 6.5 mA/A 0.18 A + 3.4 mA/A 0.83 A + 3.3 mA/A 0.095 % Fluke 5520A w/5500 coil 5520A, 3458A, amplifier, shunt w/3KA coil DC High Voltage – Measure3 (1 to 10) kV (10 to 70) kV 0.68 V + 0.33 mV/V 7.8 V + 0.47 mV/V Vitrek 4700 w/HVL-70 probe DC Current – Measure3 100 nA 100 nA to 1 µA (1 to 10) µA (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 3) A (3 to 10) A 41 pA + 89 µA/A 70 pA + 21 µA/A 0.7 nA + 18 µA/A 5.8 nA + 9.2 µA/A 58 nA + 9.7 µA/A 0.58 µA + 8 µA/A 5.8 µA + 17 µA/A 59 µA + 81 µA/A 4 mA + 0.54 mA/A 5.6 mA + 1 mA/A HP 3458A Fluke 8845A DC Current – Measure & Generate3 (10 to 300) A (300 to 1000) A 0.0053 % 0.17 % Shunts, 3458A DC Power – Generate3 (0.33 to 3.2999) mA (3.3 to 32.999) mA (33 to 329.99) mA (0.33 to 2.2999) A (3 to 20.5) A 33 mV to 1020 V Up to 3 W (3 to 30) W (30 to 300) W (300 to 3) kW (3 to 20.9) kW 0.017 % 0.014 % 0.014 % 0.033 % 0.14 % Fluke 5520A DC Voltage – Generate3 (0 to 329.9999) µV 330 µV to 3.299 999 V (3.3 to 32.999 99) V (33 to 329.9999) V (330 to 1000) V 0.8 µV + 16 nV/mV 17 µV + 5 µV/V 88 µV + 7 µV/V 0.56 mV + 14 µV/V 2.7 mV + 14 µV/V Fluke 5520A
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 11 of 19 Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Measure3 Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V 0.33 µV + 17 µV/V 0.52 µV + 8 µV/V 8.8 µV + 8.1 µV/V 35 µV + 10 µV/V 1.2 mV + 11 µV/V HP 3458A Electrical Simulation of RTDs 3 – Pt 385, 100 Ω Pt 3926, 100 Ω PtNi 385, 120 Ω Pt 385, 200 Ω Pt 385, 500 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.057 °C 0.056 °C 0.068 °C 0.081 °C 0.088 °C 0.1 °C 0.19 °C 0.056 °C 0.056 °C 0.068 °C 0.081 °C 0.088 °C 0.1 °C 0.062 °C 0.062 °C 0.11 °C 0.051 °C 0.051 °C 0.051 °C 0.057 °C 0.1 °C 0.11 °C 0.12 °C 0.13 °C 0.051 °C 0.056 °C 0.056 °C 0.062 °C 0.074 °C 0.074 °C 0.081 °C 0.095 °C Fluke 5520A
to 1000 V
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 12 of 19 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of RTDs3 – (cont) Pt 385, 1000 Ω Pt 3916, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.047 °C 0.047 °C 0.051 °C 0.057 °C 0.062 °C 0.068 °C 0.068 °C 0.18 °C 0.2 °C 0.051 °C 0.056 °C 0.062 °C 0.068 °C 0.074 °C 0.081 °C 0.041 °C 0.18 °C Fluke 5520A Electrical Simulation of Thermocouple3 – Type E Type J Type K Type S Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) C (1000 to 1372) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.39 °C 0.13 °C 0.12 °C 0.13 °C 0.17 °C 0.21 °C 0.13 °C 0.12 °C 0.14 °C 0.18 °C 0.26 °C 0.15 °C 0.13 °C 0.21 °C 0.31 °C 0.37 °C 0.28 °C 0.29 °C 0.36 °C 0.49 °C 0.21 °C 0.15 °C 0.14 °C Fluke 5520A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 13 of 19 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Oscilloscope3 – DC Signal Into 50 Ω DC Signal Into 1 MΩ Squarewave Into 50 Ω Squarewave Into 1 MΩ Edge into 50 Ω Leveled Sine Wave Amplitude – Range: 5 mV to 5.5 V p-p Range: 4 mV to 3.5 V p-p Time Marker Into 50 Ω Generate & Measure (0 to 6.6) V (0 to 130) V 1 mV to 6.6 V p-p 10 Hz to 10 kHz 1 mV to 130 Vp-p 10 Hz to 10 kHz (200 to 300) ps (1 to 2) MHz (200 to 350) ps (2 to 10) MHz 50 kHz Reference 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 5 s to 50 ms 20 ms to 1 ns 33 µV + 2 mV/V 33 µV + 0.39 µV/V 91 µV + 4.3 mV/V 0.2 mV + 0.8 mV/V 82 ps 82 ps 0.33 mV + 18 mV/V 0.4 mV + 31 mV/V 0.43 mV + 36 mV/V 0.53 mV + 57 mV/V 0.58 mV + 67 mV/V 0.002 % + (t/1000) % 0.000 36 % Fluke 5520A/SC1100 t = seconds Fluke 5520A/ SC1100 Resistance – Generate3 (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (330 to 1099.999) Ω (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ (330 to 1099.999) kΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 1.2 mΩ + 24 µΩ/Ω 1.5 mΩ + 24 µΩ/Ω 1.9 mΩ + 22 µΩ/Ω 4.1 mΩ + 22 µΩ/Ω 9.1 mΩ + 22 µΩ/Ω 41 mΩ + 22 µΩ/Ω 92 mΩ + 22 µΩ/Ω 0.41 Ω + 22 µΩ/Ω 0.9 Ω + 22 µΩ/Ω 8.4 Ω + 26 µΩ/Ω 14 Ω + 26 µΩ/Ω 93 Ω + 48 µΩ/Ω 0.4 kΩ + 0.1 mΩ/Ω 4.4 kΩ + 0.2 mΩ/Ω 16 kΩ + 0.4 mΩ/Ω 0.35 MΩ + 2.4 mΩ/Ω 4.4 MΩ + 12 mΩ/Ω Fluke 5520A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 14 of 19 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Resistance – Generate3 (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ (1 to 10) GΩ (10 to 100) GΩ 1.2 kΩ + 1.2 mΩ/Ω 12 kΩ + 1.2 mΩ/Ω 0.23 MΩ + 2.3 mΩ/Ω 5.8 MΩ + 5.8 mΩ/Ω 0.12 GΩ + 12 mΩ/Ω Decade resistor Resistance – Generate, Fixed Point3 1 mΩ 10 mΩ 100 mΩ 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 0.061 µΩ 0.38 µΩ 5 µΩ 33 µΩ 0.21 mΩ 2.2 mΩ 21 mΩ 0.21 Ω 2.1 Ω 24 Ω Standard resistors DC Resistance3 – Generate, Fixed Points, High Voltage < 20 V Up to 1000 V (1 to 5) kV (1 to 10) kV 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 TΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 TΩ 0.0013 % 0.0013 % 0.0013 % 0.0022 % 0.004 % 0.012 % 0.062 % 0.24 % 0.36 % 0.51 % 1.5 % 0.54 % 0.5 % 0.5 % 0.5 % 0.51 % 0.51 % 2.8 % IET VRS-100-11- 1K-BP
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 15 of 19 Parameter/Range Frequency CMC2, 5 (±) Comments Distortion – Measure3 20 Hz to 20 kHz (20 to 100) kHz 100 kHz to 1.8 GHz 1.2 dB 2.3 dB 1.9 dB 8903B 8591E DC Resistance – Measure3 (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 55 µΩ + 15 µΩ/Ω 0.52 mΩ + 13 µΩ/Ω 0.53 mΩ + 10 µΩ/Ω 5.3 mΩ + 10 µΩ/Ω 53 mΩ + 11 µΩ/Ω 2.3 Ω + 17 µΩ/Ω 0.1 kΩ + 55 µΩ/Ω 1 kΩ + 0.52 mΩ/Ω 10 kΩ + 5.1 mΩ/Ω Agilent 3458A IV. RF/Microwave Parameter/Equipment Range CMC2, 4, 6 (±) Comments Absolute Power – Measure 100 kHz to 4.2 GHz (+10 to +20) dBm (-30 to +10) dBm 3.6 % 1.1 % E4418B w/8482A Bandwidth – High Frequency Oscilloscopes 100 kHz to 3.2 GHz (-30 to +10) dBm 4.1 % E4418B w/8482A, power splitter & signal generator V. Fluid Quantities Parameter/Equipment Range CMC2, 4, 6 (±) Comments Gas Flow – Measuring Equipment (100 to 1000) sccm (1 to 50) SLM 0.28 % 0.28 % DHI Molbloc system
16ASTM-See scope document
17--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 17 of 19 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Scales3 (2 to 1250) lbs 0.82 x Resolution Class F weights Balances3 with Display Resolutions of (0.0001 to 10) g Up to 5 kg 0.82 x Resolution Class 2 & 3 weights Scales3 – Substitution Testing (1250 to 2500) lbs (2500 to 3750) lbs 1.2 x Resolution 1.4 x Resolution Class F weights, test loads Torque Transducers – Measuring Equipment3 (5 to 200) ozf·in (10 to 150 lbf·in 150 lbf·in to 250 lbf·ft (250 to 1000) lbf·ft 0.037 % 0.035 % 0.035 % 0.11 % Torque arms, Class F weights Torque Wrenches – Measuring Equipment3 (2.5 to 10) lbf·in (10 to 100) lbf·in (8.3 to 100) lbf·ft (100 to 1000) lbf·ft 0.58 % 0.14 % 0.14 % 0.15 % Torque calibrator VII. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measure (-200 to 660) °C 0.018 °C + 0.000 043 x TChange from -200 °C 1524 DRO, 5609 PRT Temperature – Measuring Equipment (-30 to 140) °C (140 to 660) °C 0.071 °C + 0.000 096 x TChange from -30 °C 0.081 °C + 0.000 08 x TChange from 140 °C Drywell, 1524 DRO, 5609 PRT Temperature – Measure, Climatic (Temperature Uniformity Survey)3 (-30 to 260) °C 1.2 °C + 0.0015 x TChange from -30 °C Fluke 2638A, input module, thermocouples
2 to 1250 lbs
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 18 of 19 Parameter/Equipment Range CMC2, 6 (±) Comments Relative Humidity – Measure3 (15 to 80) % RH 1.4 % RH Vaisala MI70 w/ HMP77 probe Relative Humidity – Measuring Equipment (0 to 30) %RH (30 to 70) %RH (70 to ≤ 80) %RH (> 80 to 95) %RH 1.2 % RH 1.3 % RH 1.4 % RH 1.7 % RH Fluke 5128A VII. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment 100 µHz to 15 MHz 15 MHz to 3 GHz 10 MHz 29 nHz + 6.5 pHz/Hz 0.59 mHz + 6.4 pHz/Hz 65 µHz HP 33120A function generator HP 8648C signal generator Agilent 58503B GPS Frequency – Measure3 0.1 Hz to 3 GHz 0.86 nHz + 12 pHz/Hz Frequency counter, phase locked to Agilent 58503BA Stop Watches & Timers ± 19.99 sec/day 0.037 sec/day Timometer Tachometers3 – Photo Up to 100 000 rpm 0.000 35 rpm + 0.000 055 rpm/rpm Function generator, GPS receiver Stroboscope3 2 Hz to 2000 kHz (120 to 100 000) rpm 12 nHz + 1.2 µHz/Hz Frequency counter, pickup _____________________________ 1 This laboratory offers commercial calibration service and field calibration service.
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1078.02) 09/15/2025 Page 19 of 19 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages are to be read as percent of reading, unless noted otherwise. 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eith er a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
20ISO/IEC 17025:20 17; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

5455 W Waters Avenue, Suite 210, Tampa, FL, 33634, US

27.94499, -82.45831

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.