Trescal, Inc - Tampa, FL
5455 W Waters Avenue, Suite 210, 33634, Tampa, FL, United States
Visit website- Scope lines
- 20
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 20 scope lines.
A2LA certificate 1078.02 · 20 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 2 of 19
Parameter/Equipment
Range
CMC2 (±)
Comments
Cylindrical Plugs / Pins
Up to 1 in
27 µin + 5.4 µin/in
Laser mic w/ master
pins
Height Gages3
Up to 48 in
13 µin + 5.3 µin/in
Gage blocks
Indicators3
Up to 4 in
6.5 µin + 3.2 µin/in
Gage blocks
Micrometers –
Depth, Inside, Outside
Groove
Up to 80 in
Up to 4 in
8.3 µin + 4.8 µin/in
8.3 µin + 4.9 µin/in
Gage blocks
Flatness
Up to 1 in
diameter
5.5 µin
Optical flat
Protractors3
Digital & Bevel
(0 to 90)°
0.085°
Sine bar, gage blocks,
cylindrical square,
surface plate
Surface Plate3 –
Flatness
Repeatability
Up to 100 in
diagonal
Up to 0.001 in
√DL x 12 µin
31 µin
Level meters (DL is the
diagonal in inches)
Repeat-o-meter | to 1 in |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 3 of 19
III. Electrical – DC/Low Frequency
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Generate3
(29 to 329.99) µA
330 µA to 3.2999 mA
(3.3 to 32.999) mA
(33 to 329.99) mA
330 mA to 1.099 99 A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.13 µA + 1.6 nA/µA
0.12 µA + 1.2 nA/µA
0.11 µA + 1 nA/µA
0.19 µA + 2.4 nA/µA
0.35 µA + 6.4 nA/µA
0.70 µA + 13 nA/µA
0.65 µA + 1.6 µA/mA
0.45 µA + 1 µA/mA
0.39 µA + 0.8 µA/mA
0.69 µA + 1.6 µA/mA
2.9 µA + 1.6 µA/mA
3.4 µA + 8 µA/mA
6.4 µA + 1.4 µA/mA
4 µA + 0.72 µA/mA
2.7 µA + 0.32 µA/mA
3.7 µA + 0.64 µA/mA
7.7 + 1.6 µA/mA
14 µA + 3.2 µA/mA
65 µA + 1.4 µA/mA
42 µA + 0.72 µA/mA
29 µA + 0.31 µA/mA
68 µA + 0.8 µA/mA
0.13 mA + 1.6 µA/mA
0.27 mA + 3.2 µA/mA
0.56 mA + 1.4 mA/A
0.22 mA + 0.4 mA/A
2.4 mA + 4.8 mA/A
11 mA + 20 mA/A
1.7 mA + 1.4 mA/A
0.61 mA + 0.48 mA/A
6.1 mA + 4.8 mA/A
26 mA + 20 mA/A
3.1 mA + 0.48 mA/A
4 mA + 0.8 mA/A
74 mA + 24 mA/A
15 mA + 0.96 mA/A
17 mA + 1.2 mA/A
0.27 A + 24 mA/A
Fluke 5520A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 4 of 19
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Current – Generate3
Toroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
Nontoroidal:
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(20 to 120) A
(120 to 3000) A
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(45 to 65) Hz
26 mA + 2.1 mA/A
50 mA + 1.9 mA/A
0.34 A + 1.9 mA/A
60 mA + 6 mA/A
0.11 A + 5.3 mA/A
0.86 A + 5.3 mA/A
60 mA + 3.8 mA/A
0.23 A + 3.7 mA/A
1.2 A + 3.7 mA/A
90 mA + 7.2 mA/A
0.28 A + 6.7 mA/A
1.6 A + 6.7 mA/A
0.16 %
0.13 %
Fluke 5520A w/
5500A coil
5520A, 3458A,
amplifier & shunt
5520A, amplifier,
Shunt, 3458A
w/3KA coil
AC Current – Measure3
(5 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
58 nA + 4 mA/A
45 nA + 1.5 mA/A
41 nA + 0.64 mA/A
0.43 µA + 0.0041 mA/mA
0.31 µA + 0.0016 mA/mA
0.26 µA + 0.000 67 mA/mA
0.25 µA + 0.000 37 mA/mA
0.26 µA + 0.000 67 mA/mA
0.63 µA + 0.0042 mA/mA
1.8 µA + 0.0056 mA/mA
2.4 µA + 0.0041 mA/mA
2.3 µA + 0.0016 mA/mA
2.3 µA + 0.000 67 mA/mA
2.3 µA + 0.000 37 mA/mA
2.3 µA + 0.000 67 mA/mA
4.5 µA + 0.0041 mA/mA
16 µA + 0.0056 mA/mA
HP 3458A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 5 of 19
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Current – Measure3
(cont)
(10 to 100) mA
(0.1 to 1) A
(1 to 3) A
(3 to 10) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
10 Hz to 5 kHz
(5 to 10) kHz
10 Hz to 5 kHz
(5 to 10) kHz
42 µA + 0.004 mA/mA
30 µA + 0.0015 mA/mA
25 µA + 0.0006 mA/mA
24 µA + 0.0003 mA/mA
25 µA + 0.0006 mA/mA
62 µA + 0.004 mA/mA
0.18 mA + 0.0055 mA/mA
0.42 mA + 0.0041 A/A
0.3 mA + 0.0017 A/A
0.26 mA + 0.0009 A/A
0.27 mA + 0.0011 A/A
0.37 mA + 0.0031 A/A
0.92 mA + 0.01 A/A
2.9 mA + 1.1 mA/A
20 mA + 2.7 mA/A
12 mA + 0.9 mA/A
63 mA + 2.7 mA/A
HP 3458A
Fluke 8845A
AC High Voltage –
Measure3
(1 to 10) kV
(10 to 50) kV
50/60/400 Hz
1.6 V + 1.4 mV/V
14 V + 1.2 mV/V
Vitrek 4700
w/HVL-70 probe
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
AC Power – Generate3
(45 to 65) Hz, PF = 1
Up to 32.999 mA
(33 to 329.999) mA
(0.33 to 1.099 99) A
(1.1 to 2.9999) A
(3 to 10.999 99) A
(11 to 20.5) A
Up to 1020 V
Up to 33 W
(33 to 330) W
330 W to 1.1 kW
(1.1 to 3) kW
(3 to 11) kW
(11 to 20.9) kW
0.1 %
0.062 %
0.072 %
0.075 %
0.087 %
0.14 %
Fluke 5520A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 6 of 19
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Flatness – Measure3
10 Hz to 1 MHz
(1 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
(50 to 70) MHz
(70 to 80) MHz
(80 to 100) MHZ
0.039 %
0.074 %
0.1 %
0.25 %
0.5 %
0.63 %
0.93 %
EL1100 TVC
AC Voltage – Generate3
(1 to 33) mV
(33 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
5.5 µV + 0.64 µV/mV
5 µV + 0.12 µV/mV
5 µV + 0.16 µV/mV
5.6 µV + 0.8 µV/mV
12 µV + 2.8 µV/mV
47 µV + 6.4 µV/mV
47 µV + 6.4 µV/mV
14 µV + 0.24 µV/mV
24 µV + 87 nV/mV
11 µV + 0.13 µV/mV
35 µV + 0.28 µV/mV
47 µV + 0.64 µV/mV
0.11 mV + 1.6 µV/mV
0.11 mV + 1.6 µV/mV
0.12 mV + 0.24 mV/V
88 µV + 0.12 mV/V
99 µV + 0.15 mV/V
0.12 mV + 0.24 mV/V
0.29 mV + 0.56 mV/V
1.1 mV + 1.9 mV/V
1.1 mV + 1.9 mV/V
1.3 mV + 0.24 mV/V
0.94 mV + 0.12 mV/V
1.6 mV + 0.18 mV/V
1.4 mV + 0.28 mV/V
3.7 mV + 0.72 mV/V
6.8 mV + 0.15 mV/V
10 mV + 0.16 mV/V
12 mV + 0.2 mV/V
13 mV + 0.24 mV/V
93 mV + 1.6 mV/V
87 mV + 0.24 mV/V
74 mV + 0.2 mV/V
88 mV + 0.24 mV/V
Fluke 5520A | ||
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 7 of 19
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage3 – Measure
Up to 100 mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
6.1 µV + 0.0003 mV/mV
4.1 µV + 0.0002 mV/mV
4.2 µV + 0.0003 mV/mV
4.9 µV + 0.001 mV/mV
9 µV + 0.005 mV/mV
45 µV + 0.04 mV/mV
12 µV + 0.000 07 mV/mV
2.7 µV + 0.000 07 mV/mV
11 µV + 0.000 14 mV/mV
12 µV + 0.0003 mV/mV
17 µV + 0.0008 mV/mV
47 µV mV + 0.003 mV/mV
0.12 mV + 0.01 mV/mV
3.8 mV + 0.01 mV/mV
0.12 mV + 0.000 07 V/V
0.1 mV + 0.000 07 V/V
0.11 mV + 0.000 14 V/V
0.12 mV + 0.0003 V/V
0.17 mV + 0.0008 V/V
0.47 mV + 0.003 V/V
1.2 mV + 0.010 V/V
38 mV + 0.015 V/V
1.2 mV + 0.000 07 V/V
1 mV + 0.000 07 V/V
1 mV + 0.000 14 V/V
1.2 mV + 0.0003 V/V
1.7 mV + 0.0008 V/V
4.7 mV + 0.003 V/V
12 mV + 0.01 V/V
0.38 V + 0.015 V/V
13 mV + 0.0002 V/V
11 mV + 0.0002 V/V
11 mV + 0.0002 V/V
13 mV + 0.000 35 V/V
21 mV + 0.0012 V/V
57 mV + 0.004 V/V
0.17 V + 0.015 V/V
Agilent 3458A | to 1000 V |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 8 of 19
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Capacitance3 –
Generate
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) μF
(1.1 to 3.299 99) μF
(3.3 to 10.9999) μF
(11 to 32.9999) μF
(33 to 109.999) μF
(110 to 329.999) μF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
8.8 pF + 4 pF/nF
9.7 pF + 4 pF/nF
13 pF + 4 pF/nF
15 pF + 2 pF/nF
0.1 nF + 2 pF/nF
0.15 nF + 2 pF/nF
0.46 nF + 2 pF/nF
1.5 nF + 2 nF/µF
4.6 nF + 2 nF/µF
15 nF + 2 nF/µF
59 nF + 3.2 nF/µF
0.2 µF + 3.6 nF/µF
0.64 µF + 3.6 nF/µF
2 µF + 3.6 µF/mF
7 µF + 3.5 µF/mF
38 µF + 2.6 µF/mF
90 µF + 6 µF/mF
0.37 mF + 8.8 µF/mF
Fluke 5520A
Capacitance –
Generate, Fixed Points3
1 nF
2 nF
10 nF
20 nF
500 nF
1 µF
100 Hz
1 kHz
100 Hz
1 kHz
100 Hz
1 kHz
100 Hz
1 kHz
100 Hz
1 kHz
100 Hz
1 kHz
0.042 %
0.024 %
0.015 %
0.024 %
0.042 %
0.024 %
0.042 %
0.024 %
0.042 %
0.024 %
0.042 %
0.024 %
GenRad 1409 &
509 standard
capacitors | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 9 of 19
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
Inductance – Generate,
Fixed Points3
100 µH
500 µH
1 mH
5 mH
50 mH
500 mH
1 H
100 Hz to 1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz to 1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz to 1 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
0.052 %
0.053 %
0.62 %
0.32 %
0.11 %
0.03 %
0.5 %
0.052 %
0.053 %
0.071 %
0.042 %
0.033 %
0.024 %
0.5 %
0.042 %
0.042 %
0.033 %
0.024 %
0.5 %
0.052 %
0.042 %
0.042 %
0.034 %
0.025 %
0.17 %
GenRad 1482
standard inductors
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Current – Generate3
(0 to 329.999) µ A
330 µA to 3.299 99 mA
(3.3 to 32.9999) mA
(33 to 329.999) mA
330 mA to 1.099 99 A
(1.1 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(20 to 120) A
16 nA + 0.12 nA/µA
41 nA + 80 nA/mA
0.21 µA + 80 nA/mA
2.1 µA + 80 nA/mA
33 µA + 0.16 mA/A
0.37 mA + 0.13 mA/A
0.49 mA + 0.39 mA/A
9.4 mA + 0.8 mA/A
0.024 %
Fluke 5520A
5520A, 3458A
amplifier w/shunt | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 10 of 19
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Current – Generate3
(cont)
Clamp Meters
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(120 to 3000) A
50 mA + 6.5 mA/A
0.18 A + 3.4 mA/A
0.83 A + 3.3 mA/A
0.095 %
Fluke 5520A
w/5500 coil
5520A, 3458A,
amplifier, shunt
w/3KA coil
DC High Voltage – Measure3
(1 to 10) kV
(10 to 70) kV
0.68 V + 0.33 mV/V
7.8 V + 0.47 mV/V
Vitrek 4700
w/HVL-70
probe
DC Current – Measure3
100 nA
100 nA to 1 µA
(1 to 10) µA
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 3) A
(3 to 10) A
41 pA + 89 µA/A
70 pA + 21 µA/A
0.7 nA + 18 µA/A
5.8 nA + 9.2 µA/A
58 nA + 9.7 µA/A
0.58 µA + 8 µA/A
5.8 µA + 17 µA/A
59 µA + 81 µA/A
4 mA + 0.54 mA/A
5.6 mA + 1 mA/A
HP 3458A
Fluke 8845A
DC Current – Measure &
Generate3
(10 to 300) A
(300 to 1000) A
0.0053 %
0.17 %
Shunts, 3458A
DC Power – Generate3
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(33 to 329.99) mA
(0.33 to 2.2999) A
(3 to 20.5) A
33 mV to 1020 V
Up to 3 W
(3 to 30) W
(30 to 300) W
(300 to 3) kW
(3 to 20.9) kW
0.017 %
0.014 %
0.014 %
0.033 %
0.14 %
Fluke 5520A
DC Voltage – Generate3
(0 to 329.9999) µV
330 µV to 3.299 999 V
(3.3 to 32.999 99) V
(33 to 329.9999) V
(330 to 1000) V
0.8 µV + 16 nV/mV
17 µV + 5 µV/V
88 µV + 7 µV/V
0.56 mV + 14 µV/V
2.7 mV + 14 µV/V
Fluke 5520A | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 11 of 19
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
DC Voltage – Measure3
Up to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
0.33 µV + 17 µV/V
0.52 µV + 8 µV/V
8.8 µV + 8.1 µV/V
35 µV + 10 µV/V
1.2 mV + 11 µV/V
HP 3458A
Electrical Simulation of
RTDs
3 –
Pt 385, 100 Ω
Pt 3926, 100 Ω
PtNi 385, 120 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.057 °C
0.056 °C
0.068 °C
0.081 °C
0.088 °C
0.1 °C
0.19 °C
0.056 °C
0.056 °C
0.068 °C
0.081 °C
0.088 °C
0.1 °C
0.062 °C
0.062 °C
0.11 °C
0.051 °C
0.051 °C
0.051 °C
0.057 °C
0.1 °C
0.11 °C
0.12 °C
0.13 °C
0.051 °C
0.056 °C
0.056 °C
0.062 °C
0.074 °C
0.074 °C
0.081 °C
0.095 °C
Fluke 5520A | to 1000 V |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 12 of 19
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
RTDs3 – (cont)
Pt 385, 1000 Ω
Pt 3916, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.047 °C
0.047 °C
0.051 °C
0.057 °C
0.062 °C
0.068 °C
0.068 °C
0.18 °C
0.2 °C
0.051 °C
0.056 °C
0.062 °C
0.068 °C
0.074 °C
0.081 °C
0.041 °C
0.18 °C
Fluke 5520A
Electrical Simulation of
Thermocouple3 –
Type E
Type J
Type K
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) C
(1000 to 1372) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.39 °C
0.13 °C
0.12 °C
0.13 °C
0.17 °C
0.21 °C
0.13 °C
0.12 °C
0.14 °C
0.18 °C
0.26 °C
0.15 °C
0.13 °C
0.21 °C
0.31 °C
0.37 °C
0.28 °C
0.29 °C
0.36 °C
0.49 °C
0.21 °C
0.15 °C
0.14 °C
Fluke 5520A | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 13 of 19
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Oscilloscope3 –
DC Signal Into 50 Ω
DC Signal Into 1 MΩ
Squarewave Into 50 Ω
Squarewave Into 1 MΩ
Edge into 50 Ω
Leveled Sine Wave
Amplitude –
Range: 5 mV to 5.5 V
p-p
Range: 4 mV to 3.5 V
p-p
Time Marker Into 50 Ω
Generate & Measure
(0 to 6.6) V
(0 to 130) V
1 mV to 6.6 V
p-p
10 Hz to 10 kHz
1 mV to 130 Vp-p
10 Hz to 10 kHz
(200 to 300) ps
(1 to 2) MHz
(200 to 350) ps
(2 to 10) MHz
50 kHz Reference
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
5 s to 50 ms
20 ms to 1 ns
33 µV + 2 mV/V
33 µV + 0.39 µV/V
91 µV + 4.3 mV/V
0.2 mV + 0.8 mV/V
82 ps
82 ps
0.33 mV + 18 mV/V
0.4 mV + 31 mV/V
0.43 mV + 36 mV/V
0.53 mV + 57 mV/V
0.58 mV + 67 mV/V
0.002 % + (t/1000) %
0.000 36 %
Fluke
5520A/SC1100
t = seconds
Fluke 5520A/
SC1100
Resistance – Generate3
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(330 to 1099.999) Ω
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
(330 to 1099.999) kΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
1.2 mΩ + 24 µΩ/Ω
1.5 mΩ + 24 µΩ/Ω
1.9 mΩ + 22 µΩ/Ω
4.1 mΩ + 22 µΩ/Ω
9.1 mΩ + 22 µΩ/Ω
41 mΩ + 22 µΩ/Ω
92 mΩ + 22 µΩ/Ω
0.41 Ω + 22 µΩ/Ω
0.9 Ω + 22 µΩ/Ω
8.4 Ω + 26 µΩ/Ω
14 Ω + 26 µΩ/Ω
93 Ω + 48 µΩ/Ω
0.4 kΩ + 0.1 mΩ/Ω
4.4 kΩ + 0.2 mΩ/Ω
16 kΩ + 0.4 mΩ/Ω
0.35 MΩ + 2.4 mΩ/Ω
4.4 MΩ + 12 mΩ/Ω
Fluke 5520A | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 14 of 19
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Resistance – Generate3
(1 to 10) MΩ
(10 to 100) MΩ
100 MΩ to 1 GΩ
(1 to 10) GΩ
(10 to 100) GΩ
1.2 kΩ + 1.2 mΩ/Ω
12 kΩ + 1.2 mΩ/Ω
0.23 MΩ + 2.3 mΩ/Ω
5.8 MΩ + 5.8 mΩ/Ω
0.12 GΩ + 12 mΩ/Ω
Decade resistor
Resistance – Generate,
Fixed Point3
1 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
0.061 µΩ
0.38 µΩ
5 µΩ
33 µΩ
0.21 mΩ
2.2 mΩ
21 mΩ
0.21 Ω
2.1 Ω
24 Ω
Standard resistors
DC Resistance3 –
Generate, Fixed
Points, High Voltage
< 20 V
Up to 1000 V
(1 to 5) kV
(1 to 10) kV
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 TΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 TΩ
0.0013 %
0.0013 %
0.0013 %
0.0022 %
0.004 %
0.012 %
0.062 %
0.24 %
0.36 %
0.51 %
1.5 %
0.54 %
0.5 %
0.5 %
0.5 %
0.51 %
0.51 %
2.8 %
IET VRS-100-11-
1K-BP | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 15 of 19
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
Distortion – Measure3
20 Hz to 20 kHz
(20 to 100) kHz
100 kHz to 1.8 GHz
1.2 dB
2.3 dB
1.9 dB
8903B
8591E
DC Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
55 µΩ + 15 µΩ/Ω
0.52 mΩ + 13 µΩ/Ω
0.53 mΩ + 10 µΩ/Ω
5.3 mΩ + 10 µΩ/Ω
53 mΩ + 11 µΩ/Ω
2.3 Ω + 17 µΩ/Ω
0.1 kΩ + 55 µΩ/Ω
1 kΩ + 0.52 mΩ/Ω
10 kΩ + 5.1 mΩ/Ω
Agilent 3458A
IV. RF/Microwave
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Absolute Power – Measure
100 kHz to 4.2 GHz
(+10 to +20) dBm
(-30 to +10) dBm
3.6 %
1.1 %
E4418B w/8482A
Bandwidth – High
Frequency Oscilloscopes
100 kHz to 3.2 GHz
(-30 to +10) dBm
4.1 %
E4418B w/8482A,
power splitter &
signal generator
V. Fluid Quantities
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Gas Flow – Measuring
Equipment
(100 to 1000) sccm
(1 to 50) SLM
0.28 %
0.28 %
DHI Molbloc
system | ||
| 16 | ASTM | - | See scope document |
| 17 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 17 of 19
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
Scales3
(2 to 1250) lbs
0.82 x Resolution
Class F weights
Balances3
with Display Resolutions
of (0.0001 to 10) g
Up to 5 kg
0.82 x Resolution
Class 2 & 3
weights
Scales3 – Substitution
Testing
(1250 to 2500) lbs
(2500 to 3750) lbs
1.2 x Resolution
1.4 x Resolution
Class F weights,
test loads
Torque Transducers –
Measuring Equipment3
(5 to 200) ozf·in
(10 to 150 lbf·in
150 lbf·in to 250 lbf·ft
(250 to 1000) lbf·ft
0.037 %
0.035 %
0.035 %
0.11 %
Torque arms,
Class F weights
Torque Wrenches –
Measuring Equipment3
(2.5 to 10) lbf·in
(10 to 100) lbf·in
(8.3 to 100) lbf·ft
(100 to 1000) lbf·ft
0.58 %
0.14 %
0.14 %
0.15 %
Torque calibrator
VII. Thermodynamics
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Temperature – Measure
(-200 to 660) °C
0.018 °C + 0.000 043 x
TChange from -200 °C
1524 DRO, 5609
PRT
Temperature –
Measuring Equipment
(-30 to 140) °C
(140 to 660) °C
0.071 °C + 0.000 096 x
TChange from -30 °C
0.081 °C + 0.000 08 x
TChange from 140 °C
Drywell, 1524
DRO, 5609 PRT
Temperature –
Measure, Climatic
(Temperature Uniformity
Survey)3
(-30 to 260) °C
1.2 °C + 0.0015 x TChange from
-30 °C
Fluke 2638A,
input module,
thermocouples | 2 to 1250 lbs |
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 18 of 19
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Relative Humidity –
Measure3
(15 to 80) % RH
1.4 % RH
Vaisala MI70 w/
HMP77 probe
Relative Humidity –
Measuring Equipment
(0 to 30) %RH
(30 to 70) %RH
(70 to ≤ 80) %RH
(> 80 to 95) %RH
1.2 % RH
1.3 % RH
1.4 % RH
1.7 % RH
Fluke 5128A
VII. Time & Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Frequency – Measuring
Equipment
100 µHz to 15 MHz
15 MHz to 3 GHz
10 MHz
29 nHz + 6.5 pHz/Hz
0.59 mHz + 6.4 pHz/Hz
65 µHz
HP 33120A function
generator
HP 8648C signal
generator
Agilent 58503B GPS
Frequency – Measure3
0.1 Hz to 3 GHz
0.86 nHz + 12 pHz/Hz
Frequency counter,
phase locked to
Agilent 58503BA
Stop Watches & Timers
± 19.99 sec/day
0.037 sec/day
Timometer
Tachometers3 –
Photo
Up to 100 000 rpm
0.000 35 rpm
+ 0.000 055 rpm/rpm
Function generator,
GPS receiver
Stroboscope3
2 Hz to 2000 kHz
(120 to 100 000) rpm
12 nHz + 1.2 µHz/Hz
Frequency counter,
pickup
_____________________________
1 This laboratory offers commercial calibration service and field calibration service. | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1078.02) 09/15/2025 Page 19 of 19
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, percentages are to be read as percent of reading, unless noted otherwise.
5 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as eith er a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 20 | ISO/IEC 17025:20 17; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Technical Maintenance, Inc. - TEMPLE TERRACETemple Terrace, FL · ~12 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- CIH Equipment CompanyClearwater, FL · ~31 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Mitutoyo America CorporationLakeland, FL · ~51 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Troxler Electronic Laboratories, Inc.Apopka, FL · ~123 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Kimball ElectronicWinter Park, FL · ~130 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .