FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
United States

Element Materials Technology - Melbourne

7780 Technology Drive, 32904, Melbourne, FL, United States

A2LA|7039.03A2LA|7039.02ISO/IEC 17025Register refreshed 2026-09-25
Certificates
2
Scope items
8
Standards
6
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Element Materials Technology - Melbourne?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
7039.03Active
7039.02Active

Accredited standards

6

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receiversCertificate says EN 55025. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 2 (A2LA 7039.03)

MIL-STD-461; RTCA/DO-160; AIRBUS ABD0100.1.2; BOEING D6-16050-4; BOEING D6-16050-5; BOEING D6-16050-6; EN 55025:2017/AC:2017-11; CISPR 25:2016/COR1:2017; ISO 11452-2

As written on the certificate · Line 2 (A2LA 7039.02)

MIL-STD-461; RTCA/DO-160; AIRBUS ABD0100.1.2; BOEING D6-16050-4; BOEING D6-16050-5; BOEING D6-16050-6; EN 55025:2017/AC:2017-11; CISPR 25:2016/COR1:2017; ISO 11452-2

ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
As written on the certificate · Line 3 (A2LA 7039.03)

ISO 11452-4; SAE J1113-4; ISO 11451-2; 11452-8:2015; ISO 7637-2:2011; RTCA/DO-160, Section 22

As written on the certificate · Line 3 (A2LA 7039.02)

ISO 11452-4; SAE J1113-4; ISO 11451-2; 11452-8:2015; ISO 7637-2:2011; RTCA/DO-160, Section 22

ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
As written on the certificate · Line 1 (A2LA 7039.03)

RTCA/DO-160; MIL-STD-704; MIL-STD-1275; MIL-STD-461; AIRBUS ABD0100.1.2; BOEING D6-16050-4; BOEING D6-16050-5; BOEING D6-16050-6; ISO 10605; SAE J1113-13; SAE J1113-2:1996-09

As written on the certificate · Line 1 (A2LA 7039.02)

RTCA/DO-160; MIL-STD-704; MIL-STD-1275; MIL-STD-461; AIRBUS ABD0100.1.2; BOEING D6-16050-4; BOEING D6-16050-5; BOEING D6-16050-6; ISO 10605; SAE J1113-13; SAE J1113-2:1996-09

ISO 11451-2Road vehicles - Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Off-vehicle radiation sources
As written on the certificate · Line 3 (A2LA 7039.03)

ISO 11452-4; SAE J1113-4; ISO 11451-2; 11452-8:2015; ISO 7637-2:2011; RTCA/DO-160, Section 22

As written on the certificate · Line 3 (A2LA 7039.02)

ISO 11452-4; SAE J1113-4; ISO 11451-2; 11452-8:2015; ISO 7637-2:2011; RTCA/DO-160, Section 22

ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
As written on the certificate · Line 2 (A2LA 7039.03)

MIL-STD-461; RTCA/DO-160; AIRBUS ABD0100.1.2; BOEING D6-16050-4; BOEING D6-16050-5; BOEING D6-16050-6; EN 55025:2017/AC:2017-11; CISPR 25:2016/COR1:2017; ISO 11452-2

As written on the certificate · Line 2 (A2LA 7039.02)

MIL-STD-461; RTCA/DO-160; AIRBUS ABD0100.1.2; BOEING D6-16050-4; BOEING D6-16050-5; BOEING D6-16050-6; EN 55025:2017/AC:2017-11; CISPR 25:2016/COR1:2017; ISO 11452-2

ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
As written on the certificate · Line 3 (A2LA 7039.03)

ISO 11452-4; SAE J1113-4; ISO 11451-2; 11452-8:2015; ISO 7637-2:2011; RTCA/DO-160, Section 22

As written on the certificate · Line 3 (A2LA 7039.02)

ISO 11452-4; SAE J1113-4; ISO 11451-2; 11452-8:2015; ISO 7637-2:2011; RTCA/DO-160, Section 22

Scope as published by A2LA

8 lines
A2LA

ISO/IEC 17025

Active

7039.03

The scope document we hold says it is valid until 2027-02-28.

View scope

Accredited scope, certificate 7039.03

LineDisciplineMethodMatrixRange
1electricalRTCA/DO-160; MIL-STD-704; MIL-STD-1275; MIL-STD-461; AIRBUS ABD0100.1.2; BOEING D6-16050-4; BOEING D6-16050-5; BOEING D6-16050-6; ISO 10605; SAE J1113-13; SAE J1113-2:1996-09Aircraft components, automotive components, wiring harnesses, subassemblies, electronic devices-
2electricalMIL-STD-461; RTCA/DO-160; AIRBUS ABD0100.1.2; BOEING D6-16050-4; BOEING D6-16050-5; BOEING D6-16050-6; EN 55025:2017/AC:2017-11; CISPR 25:2016/COR1:2017; ISO 11452-2--
3electricalISO 11452-4; SAE J1113-4; ISO 11451-2; 11452-8:2015; ISO 7637-2:2011; RTCA/DO-160, Section 22--
4electrical
For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited ELEMENT MATERIALS TECHNOLOGY - MELBOURNE Melbourne, FL for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 11th day of February 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7039.03 Valid to February 28, 2027

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17025

Active

7039.02

The scope document we hold says it is valid until 2027-02-28.

View scope

Accredited scope, certificate 7039.02

LineDisciplineMethodMatrixRange
1electricalRTCA/DO-160; MIL-STD-704; MIL-STD-1275; MIL-STD-461; AIRBUS ABD0100.1.2; BOEING D6-16050-4; BOEING D6-16050-5; BOEING D6-16050-6; ISO 10605; SAE J1113-13; SAE J1113-2:1996-09Aircraft components, automotive components, wiring harnesses, subassemblies, electronic devices-
2electricalMIL-STD-461; RTCA/DO-160; AIRBUS ABD0100.1.2; BOEING D6-16050-4; BOEING D6-16050-5; BOEING D6-16050-6; EN 55025:2017/AC:2017-11; CISPR 25:2016/COR1:2017; ISO 11452-2--
3electricalISO 11452-4; SAE J1113-4; ISO 11451-2; 11452-8:2015; ISO 7637-2:2011; RTCA/DO-160, Section 22--
4electrical
For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited ELEMENT MATERIALS TECHNOLOGY - MELBOURNE Melbourne, FL for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 11th day of February 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7039.03 Valid to February 28, 2027

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

7780 Technology Drive, Melbourne, FL, 32904, US

28.07850, -80.60779

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.