Poland

Wojskowy Instytut Chemii i Radiometrii

Al. Gen. A. Chruściela "Montera" 105, 00-910, Warszawa, Poland

PCA AB 241PCA AB 380ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
7
PCA certificates
2
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 7 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 136
EN 140
EN 143
EN 149
EN 13274-3
EN 13274-7
EN 14387

Read from the PCA scope documents we downloaded on 2026-03-13. Register refreshed 2026-11-20.

Scope as published by PCA

6 lines
PCA

ISO/IEC 17025

Active

AB 241

The scope document we hold says it was valid until 2026-07-24. That date has passed, so our copy may be out of date. We downloaded it from the PCA register on 2026-03-13. Check the PCA register for the current scope.

View on PCA

Accredited scope, certificate AB 241

LineMethodMatrixRange
1-Construction products and materials
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

9PCA Zakres akredytacji Nr AB 241 Scope of accreditation No AB 241 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No AB 241 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 19 z/of 10.07.2024 KIEROWNIK DZIAŁU AKREDYTACJI BADAŃ EMISJI W ŚRODOWISKU MARCIN BEKAS Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr A B 241 z dnia 01.07.2020 r. Cykl akredytacji od 28.06.2022 r. do 24.07.2026 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 241 of 01.07.2020 Accreditation cycle from 28.06.2022 to 24.07.2026 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No 19, 10.07.2024 1/4 Nazwa i adres / Name and address WOJSKOWY INSTYTUT CHEMII I RADIOMETRII LABORATORIUM ANALITYCZNE DO KONTROLI PRZESTRZEGANIA KONWENCJI O ZAKAZIE BRONI CHEMICZNEJ Al. gen. Antoniego Chruściela „Montera” 105 00-910 Warszawa Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - C/4; C/8; C/9; C/15; C/21; C/28; C/31, C/35 - Badania chemiczne wyrobów chemicznych , wyrobów i materiałów konstrukcyjnych, powietrza, wyposażenia wojskowego, wyrobów z tworzyw sztucznych, wody, gleby, pomieszczeń (warunki środowiskowe – powietrze) / Chemical tests of chemical products, construction products and materials, air, military equipment, synthetic products, water, soil, facilities (environmental conditions – air) Wersja strony/page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 241
-
2CH-01 edycja 3 z dnia 15.09.2022 r.Water40 to 400 amu
3CH-15, edycja 7 z dnia 05.05.2021 r.-0.000001 to 0.01 mg/dm3

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

PCA

ISO/IEC 17025

Active

AB 380

The scope document we hold says it is valid until 2030-01-03.

View on PCA

Accredited scope, certificate AB 380

LineMethodMatrixRange
1-personal protective equipment; military equipment
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 380 Scope of accreditation No AB 380 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No AB 380 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 21 z/of 31.12.2025 KIEROWNIK BIURA DS. AKREDYTACJI TADEUSZ MATRAS Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 380 z dnia 16.10.2019 r. Cykl akredytacji od 31.12.2025 r. do 03.01.2030 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No AB 380 of 16.10.2019 Accreditation cycle from 31.12.2025 to 03.01.2030 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No 21, 31.12.2025 1/4 Nazwa i adres / Name and address : WOJSKOWY INSTYTUT CHEMII I RADIOMETRII LABORATORIUM BADAWCZE OCHRONY DRÓG ODDECHOWYCH Al. Gen. A. Chruściela „Montera” 105 00-910 Warszawa Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - C/19 - N/15; N/19 - Badania chemiczne środków ochrony osobistej / Chemical tests of personal protective equipment - Badania właściwości fizycznych wyposażenia wojskowego, środków ochrony osobistej / Physical properties tests of military equipment, personal protective equipment Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl / The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl AB 380
-
2NO-42-A210:2004/A1:2014; PN-EN 14387:2021-07; NO-42-A205:2009; NO-42-A205:2009/A1:2025; PN-EN 136:2001; PN-EN 136:2001/Ap1:2003; PN-EN 136:2001/AC:2004; PN-EN 140:2001; PN-EN 140:2001/Ap1:2003; PN-EN 149+A1:2010; NO-42-A214:2017; PN-EN 13274-3:2005; PN-EN 143:2021-07; PN-EN 14387:2021-07; PN-EN 13274-7:2019-07Materiały sorpcyjne; Pochłaniacze; Filtropochłaniacze; Maski; Półmaski i ćwierćmaski; Półmaski filtrujące; Maski przeciwgazowe; Materiały filtracyjne, filtry; Pochłaniacze i filtropochłaniacze; Filtropochłaniacze do maski przeciwgazowej; Materiały filtracyjne, filtry; Filtropochłaniacze; Półmaski filtrujące; Filtropochłaniacze do maski przeciwgazowej0 to 2000 Pa
3PN-EN 143:2021-07 p.6.12; PN-EN 14387:2021-07 p. 5.13.2; PN-EN 149+A1:2010 p. 8.11; PN-EN 13274-7:2019-07 p. 7; NO-42-A205:2009 p. 2.6; NO-42-A205:2009/A1:2025; PN-EN 136:2001 p. 8.16; PN-EN 136:2001/Ap1:2003; PN-EN 136:2001/AC:2004; NO-42-A214:2017 p. 5.15; PN-EN 136:2001 p. 8.13; NO-42-A214:2017 p. 5.11; NO-42-A214:2017 p. 5.12; NO-42-A214:2017 p. 5.10-0.0005 to 100 %

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Al. Gen. A. Chruściela "Montera" 105, Warszawa, 00-910, PL

52.23337, 21.07115

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.