Deibel Laboratories of Lakeland, Florida
1705 George Jenkins Blvd., 33815, Lakeland, FL, United States
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Deibel Laboratories of Lakeland, Florida?
Claim this profile to keep it accurate.
Register record
- A2LARefreshed
- 2833.02Active
Accredited standards
2Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
AOAC 966.24Name not checked yet
AOAC 050501; AOAC 031002; AOAC 060903; AOAC 966.24; FDA/BAM: Ch. 4; AOAC 991.14; CMMEF 5th Ed., Ch. 8; FDA/BAM: Ch. 10; AOAC 030502; AOAC 081401; AOAC 2004.06; AOAC RI 981202; AOAC 2003.12; AOAC RI 121402
AOAC 2003.09Name not checked yet
AOAC 2004.02; FDA/BAM: Ch. 5; AOAC 2003.09; RI 100201; AOAC 2013.02; AOAC 2004.03; AOAC 966.23; FDA/BAM: Ch. 3; AOAC 990.12; AOAC 975.55; FDA BAM: Ch.12; FDA/BAM: 7 th Ed., Ch. 18
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active2833.02
The scope document we hold says it is valid until 2027-09-30.
Accredited scope, certificate 2833.02
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | biological | AOAC 050501; AOAC 031002; AOAC 060903; AOAC 966.24; FDA/BAM: Ch. 4; AOAC 991.14; CMMEF 5th Ed., Ch. 8; FDA/BAM: Ch. 10; AOAC 030502; AOAC 081401; AOAC 2004.06; AOAC RI 981202; AOAC 2003.12; AOAC RI 121402 | food products, surface sponges, and swabs | - |
| 2 | biological | AOAC 2004.02; FDA/BAM: Ch. 5; AOAC 2003.09; RI 100201; AOAC 2013.02; AOAC 2004.03; AOAC 966.23; FDA/BAM: Ch. 3; AOAC 990.12; AOAC 975.55; FDA BAM: Ch.12; FDA/BAM: 7 th Ed., Ch. 18 | - | - |
| 3 | biological | ISO/IEC 17025:2017; A2LA R204 | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Silliker, Inc. dba Merieux NutriSciences GeorgiaStone Mountain, GA · ~675 kmA2LAShares 1 accredited test methodAOAC 2003.09
- Deibel Labs of TennesseeOoltewah, TN · ~835 kmA2LAShares 1 accredited test methodAOAC 2003.09
- Deibel Laboratories of VirginiaChester, VA · ~1,118 kmA2LAShares 1 accredited test methodAOAC 966.24
- Silliker, Inc. dba Merieux NutriSciences OhioColumbus, OH · ~1,329 kmA2LAShares 1 accredited test methodAOAC 2003.09
- Food Safety Net ServicesSt. Louis, MO · ~1,403 kmA2LAShares 1 accredited test methodAOAC 2003.09
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.