What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 59 standard numbers and the 47 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
KS C 9610-4-2national version with changes
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+2 national
National versions in the same scope
AS/NZS 61000.4.3probably the same standard; matched by number only
KS C 9610-4-3national version with changes
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+2 national
National versions in the same scope
AS/NZS 61000.4.4probably the same standard; matched by number only
KS C 9610-4-4national version with changes
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+2 national
National versions in the same scope
AS/NZS 61000.4.5probably the same standard; matched by number only
KS C 9610-4-5national version with changes
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+2 national
National versions in the same scope
AS/NZS 61000.4.6probably the same standard; matched by number only
KS C 9610-4-6national version with changes
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity testExclusion+2 national
Limits written next to it
EN/IEC 61000-4-8 (excluding short duration mode)
IEC 61000-4-8:2009 (excluding short duration mode)
National versions in the same scope
AS/NZS 61000.4.8probably the same standard; matched by number only
KS C 9610-4-8national version with changes
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+2 national
National versions in the same scope
AS/NZS 61000.4.11probably the same standard; matched by number only
KS C 9610-4-11probably the same standard; matched by number only
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.1national version with changes
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.2national version with changes
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000.6.3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national
National versions in the same scope
AS/NZS 61000.6.4identical to it
IEC9
IEC 60068-2-5
IEC 60439-1
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 60947-1
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2
IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
CISPR7
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
KS C 9811national version with changes
CISPR 12Vehicles, boats and devices with internal combustion engines or traction batteries - Radio disturbance characteristics - Limits and methods of measurement for the protection of off-board receivers+1 national
National versions in the same scope
AS/NZS CISPR 12national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS/NZS CISPR 24identical to it
KS C 9824probably the same standard; matched by number only
CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsExclusion+2 national
Limits written next to it
EN 55032 (excluding Annex H)
National versions in the same scope
AS/NZS CISPR 32identical to it
KS C 9832national version with changes
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsExclusion+2 national
Limits written next to it
EN 55035 (excluding Annex A-H)
National versions in the same scope
AS/NZS CISPR 35probably the same standard; matched by number only
KS C 9835national version with changes
ISO7
ISO 4892-2Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 13766Earth-moving machinery - Electromagnetic compatibility
ISO 14982Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteriaExclusion
Limits written next to it
ISO 14982 (excluding ISO 11452-3)
ISO 16750-1Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 1: General
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
ASTM5
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM D149
ASTM D257
ASTM D618
ASTM G155
ISO 11452 series5
ISO 11452-1Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 1: General principles and terminology
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-5Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 5: Stripline
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
EN3
EN 12895
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50131-1
ISO 11451 series3
ISO 11451-1Road vehicles - Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 1: General principles and terminology
ISO 11451-2Road vehicles - Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Off-vehicle radiation sources
ISO 11451-3Road vehicles - Vehicle test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 3: On-board transmitter simulation
ISO 7637 series3
ISO 7637-1Road vehicles - Electrical disturbances from conduction and coupling - Part 1: Vocabulary and general considerations
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
Other standards4
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC MP-5 (February 1986)
FCC PART 15Radio Frequency Devices
MIL-STD-810
47 CFR FCC Part 15B (using ANSI C63.4:2014); 47 CFR FCC Part 18 (using MP-5:1986); ANSI C63.4:2014; ICES-003:2020; VCCI V-3 (up to 6GHz); EN 55011; CISPR 11; AS CISPR 11; KS C 9811; CISPR 11:2015 +A1:2016 +A2:2019; EN 55022; CISPR 22; AS/NZS CISPR 22; EN 55032 (excluding Annex H); CISPR 32 (excluding Annex H); AS/NZS CISPR 32 (excluding Annex H); KS C 9832 (excluding Annex H); EN/IEC 61000-3-2; AS/NZS 61000.3.2; EN/IEC 61000-3-3; AS/NZS 61000.3.3; EN/IEC 61000-4-2; AS/NZS 610004.2; KS C 9610-4-2; IEC 61000-4-2:2008; EN/IEC 61000-4-3; AS/NZS 61000.4.3; KS C 9610-4-3; EN/IEC 61000-4-4; AS/NZS 61000.4.4; KS C 9610-4-4; IEC 61000-4-4:2012
EN/IEC 61000-4-5; AS/NZS 61000.4.5; KS C 9610-4-5; IEC 61000-4-5:2014 +A1:2017; EN/IEC 61000-4-6; AS/NZS 61000.4.6; KS C 9610-4-6; IEC 61000-4-6:2013; EN/IEC 61000-4-8 (excluding short duration mode); AS/NZS 61000.4.8 (excluding short duration mode); KS C 9610-4-8 (excluding short duration mode); IEC 61000-4-8:2009 (excluding short duration mode); EN/IEC 61000-4-11; AS/NZS 61000.4.11; KS C 9610-4-11; IEC 61000-4-11:2004 +A1:2017; MIL-STD-461C; MIL-STD-462C; MIL-STD-461E, F, and G (CE101, CE102, CE106); MIL-STD-462D (CE101, CE102, CE106); MIL-STD-462 (CE01, CE03, CE07); RTCA/DO-160 C, D, E, F, and G, Section 21; MIL-STD-461C; MIL-STD-462C; MIL-STD-461 (RE101, RE102, RE103); MIL-STD-462D (RE101, RE102, RE103); MIL-STD-462 (RE01, RE02); RTCA/DO-160 C, D, E, F, and G, Sections 15 and 21; RTCA/DO-160 C, D, E, F, and G, Section 25; MIL-STD-1686C; MIL-STD-461G (CS118); MIL-STD-461E, F, and G (RS101, RS103, RS105); MIL-STD-462D (RS101, RS103); MIL-STD-462 (RS01, RS02, RS03); MIL-STD-461C; MIL-STD-462C; RTCA/DO-160 C, D, E, F, and G, Section 20; MIL-STD-461E, F, and G (CS103, CS104, CS105, CS109, CS114, CS115, CS116); MIL-STD-461C; MIL-STD-462C; MIL-STD-462D (CS103, CS104, CS105, CS109, CS114, CS115, CS116); MIL-STD-462 (CS01, CS02, CS06); RTCA/DO-160 C, D, E, F, and G, Section 20; MIL-STD-461D, E, F, G, (RS101); MIL-STD-462 (RS01); MIL-STD-461C; MIL-STD-462C; RTCA/DO-160 C, D, E, F, G, Section 15
ANSI C63.4:2014; EN/IEC 61000-6-1; AS/NZS 61000.6.1; EN/IEC 61000-6-2; AS/NZS 61000.6.2; EN/IEC 61000-6-3; AS/NZS 61000.6.3; EN/IEC 61000-6-4; AS/NZS 61000.6.4; CISPR 24; EN 55024; AS/NZS CISPR 24; KS C 9824; CISPR 35; EN 55035; AS/NZS CISPR 35; KS C 9835; BS EN/IEC 60601-1-2; IEC 60601-1-2:2020; EN/IEC 60947-1; EN/IEC 60439-1; EN/IEC 61326-1; EN/IEC 61326-2; EN 50130-4; EN 50131-1; EN 61800-3; IEC 61800-3; ISO 7637-1; ISO 11451-1; ISO11452-1; ISO 13766:2006 Ed 2.0; ISO 14982; ISO 16750-1; EN 12895:2015; IEC 60945; ECE R10; MIL-STD-202, Method 302; ASTM D257; ASTM D149 Types 1, 3, & 4; MIL-STD-202, Method 301; MIL-STD-202, Method 303, 304, 307; MIL-DTL 83513G, Method 3.5.6
MIL-STD-810, Method 505; IEC 60068-2-5; ASTM G155; EN ISO 4892-2
MIL-STD-202, Methods 107 & 108; MIL-STD-750, Methods 1026, 1027, 1031, 1032, 1036, 1037, 1038, & 1051; MIL-STD-810, Methods 501, 502, 503, 520; MIL-STD-883, Sections 1005, 1007, 1008, 1010, & 1011; SAE J1455, Sections 4.1.3.1, 4.1.3.2, & 4.1.3.3; RTCA/DO-160, Sections 4 & 5; Ford ES-8A5A-12A. 145AA, Section 3.5; Chrysler PF 9688, Sections 2.3.1, 2.3.2, 2.3.3, 2.3.4, 2.12, & 2.13; GMW3172, Sections 8.4, 9.4.1, 9.4.2, & 9.4.3; UN/ST/SG/AC.10/11/Rev.6, Section 38.3.4.2; USCAR 2, Sections 5.6.1 & 5.6.3; MIL-STD-202, Method 105; MIL-STD-750, Method 1001; MIL-STD-810, Method 500; MIL-STD-883, Method 1001; RTCA/DO-160, Section 4 (except Category E1 and E2); UN/ST/SG/AC.10/11/Rev.6, Section 38.3.4.1; SAE J1455, Section 4.9; ASTM B117; MIL-STD-202, Method 101; MIL-STD-750, Method 1046; MIL-STD-810, Method 509; RTCA/DO-160, Section 14; Ford FLTM BI 123-01; Chrysler PF 9688, Sections 2.7 & 2.8; GMW3172, Section 9.4.7; NEMA 250, Sections 5.8, 5.9.1, & 5.10; UL50E, Procedures 8.7 – 8.9; MIL-STD-202, Method 104; MIL-STD-750, Method 1011; MIL-STD-810, Method 512; MIL-STD-883, Method 1002; SAE J1455, Section 4.3.3.2; GMW3172, Section 9.5.3; USCAR 2, Section 5.6.5; IEC 60529; MIL-STD-202, Method 208; MIL-STD-883, Method 2003; MIL-STD-202, Method 210; MIL-STD-883, Method 2036 (Test Condition A and B)
USCAR 2, Method 5.6.7.2; SAE J1455, Sections 4.4.3.1 & 4.5; NEMA 250, Sections 5.7; UL 50E, Procedures 8.3, 8.6, 8.12; RTCA/DO-160, Section 24; GMW3172, Section 9.5.5; NEMA 250, Section 5.6; MIL-STD-810; UL 50E, 8.5; IEC 60529; ISO 20653; GMW3172, Sections 9.5.2 & 9.5.3; NEMA 250, Sections 5.2, 5.3, 5.4, 5.11 & 5.12; UL 50E, Sections 8.10, 8.11; Chrysler PF 9688, Sections 2.9.2 & 2.9.5; RTCA/DO-160, Section 10; RTCA/DO-160, Section 12; MIL-STD-810, Method 510; Qualmark HALT Guidelines 933-0336; GMW3172, Section 8.3.1; Chrysler PF 9688, Sections 2.4, 2.5, & 2.6; GMW3172, Sections 9.3.1, 9.3.2, & 10.3.1; MIL-STD-202, Methods 201, 202, 204, 213, & 214; MIL-STD-750, Methods 2016 & 2056; MIL-STD-810, Methods 514 & 516; MIL-STD-883, Methods 2002, 2005, 2007, & 2026; SAE J1455, Sections 4.10 & 4.11; SAE/AS23190, Section 4.6.4.1; UN/ST/SG/AC.10/11/Rev.6, Sections 38.3.4.3 & 38.3.4.4; RTCA/DO 160, Sections 7 & 8; USCAR 2, Section 5.4.6; UN/ST/SG/AC.10/11/Rev.6, Section 38.3.4.6; USCAR 2, Section 5.4.8; ISTA 1A; MIL-STD-810, Method 516; Chrysler PF-9688, Section 2.5
MIL-STD-704A, B, C, D, E, and F; RTCA/DO-160 C, D, E, F, and G, Section 16; EN 55012; CISPR 12; AS/NZS CISPR 12; CISPR 25 for RE (2016, 2021) Section 6.5; CISPR 25 for CE (2016, 2021) Sections 6.3 and 6.4; EN 55025 (sections 6.3 and 6.4); ISO 7637-2; ISO 7637-3; ISO 10605; ISO 10605:2008; ISO 11451-2; ISO 11451-3; ISO 11452-2; ISO 11452-4; ISO 11452-5; ISO 11452-8 (Radiating Loop Method); ISO 16750-2
MIL-STD-202, Method 211; USCAR 2, Sections 5.4.2 & 5.4.3; IPC/WHMA-A-620C Section 19.7.2; MIL-STD-202, Method 215; MIL-STD-750, Method 1022; MIL-STD-810, Method 504; MIL-STD-883, Method 2015; RTCA/DO-160, Section 11; NEMA 250, Section 5.14.4; Chrysler PF-9688, Sections 2.9.1, 2.9.3, & 2.9.4; USCAR 2, Section 5.6.4; SAE J1211, Section 4.2; SAE J1455, Section 4.2; ASTM D618; GM 4465P; GMW3172, Sections 8.5.1, 9.4.5, & 9.4.6; Ford FLTM BQ 104-07; MIL-STD-202, Methods 103 & 106; MIL-STD-750, Method 1021; MIL-STD-810, Method 507; MIL-STD-883, Method 1004; RTCA/DO-160, Section 6; Chrysler PF 9688, Sections 2.3.5 & 2.3.6; USCAR 2, Section 5.6.2
FCC MP-5 (February 1986)
Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
11 lines
ISO/IEC 17025
Active214.38
The scope document we hold says it is valid until 2028-05-31.
ISO/IEC 17025
Active214.39
The scope document we hold says it is valid until 2028-05-31.
Location
Labs with overlapping accredited scope in United States
- Element Materials Technology Dallas – Plano WestPlano, TX · ~1,267 kmA2LAShares 3 accredited test methodsANSI C63.4:2014ASTM B117MIL-STD-810
- Elite Electronic EngineeringDowners Grove, IL · ~31 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ASTM B117
- Element Materials Technology RockfordRockford, IL · ~98 kmA2LAShares 2 accredited test methodsANSI C63.4:2014EN 55012
- TUV SUD AmericaAlpharetta, GA · ~944 kmA2LAShares 2 accredited test methodsANSI C63.4:2014MIL-STD-810
- EUROFINS ELECTRICAL AND ELECTRONIC TESTING NABaltimore, MD · ~1,003 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ASTM B117
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.