Larson Davis a PCB Division

1681 West 820 North, 84601, Provo, UT, United States

Visit website
A2LA 3622.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 3622.01 · 6 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3622.01) Revised 03/05/2026 Page 2 of 5 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 3 (±) Comments DC Voltage – Measure (10 to 120) mV 100 mV to 1.2 V (1 to 12) V (10 to 120) V 7.5 µV/V + 0.36 µV 9.2 µV/V + 0.32 µV 9.4 µV/V + 0.87 µV 12 µV/V + 32 µV Agilent 3458A digital multimeter Parameter/Range Frequency CMC2, 3, 4 (±) Comments AC Voltage – Measure 100 mV to 14 V (10 to 120) mV 100 mV to 1.2 V (1 to 12) V (10 to 120) V 6.3 Hz to 20 kHz 3 Hz to 50 kHz (50 to 300) kHz 3 Hz to 50 kHz (50 to 300) kHz 3 Hz to 50 kHz (50 to 300) kHz 3 Hz to 50 kHz (50 to 300) kHz 0.12 dB 0.031 % + 2.1 µV 0.31 % + 11 µV 0.031 % + 21 µV 0.31 % + 0.11 mV 0.031 % + 0.21 mV 0.31 % + 1.1 mV 0.036 % + 2.1 mV 0.41 % + 11 mV LD model 831 with ADP074 Agilent 3458A digital multimeter Attenuation – Measure, Fixed Points 40 dB 60 dB Gain 10 Hz to 20 kHz 10 Hz to 20 kHz 0.02 dB 0.05 dB Agilent (HP) 34401A digital multimeter
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3622.01) Revised 03/05/2026 Page 3 of 5 Parameter/Range Frequency CMC2, 3, 4 (±) Comments AC Voltage – Generate Sinewave: 10 mV to 14 V 30 mV to 3 V (0.1 to 30) mV 16 µV to 0.1 mV 0.01 Hz to 200 kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 126) kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 1.3 % + 1.2 µV 0.12 dB 0.06 dB 0.04 dB 0.04 dB 0.09 dB 0.50 dB 0.04 dB 0.04 dB Signal generator (SRS DS360) Signal generator (LD 2900 with 2209 or 2239) Preamplifier & Sound Level Meter – (103 to 142) dBµV 141 mV to 12.6 V (24 to 103) dBµV 15.9 µV to 141 mV (103 to 142) dBµV 141 mV to 12.6 V (24 to 103) dBµV 15.9 µV to 141 mV 3 Hz to 20 kHz 3 Hz to 20 kHz (2.5 to 5) Hz (5 to 10) Hz 10 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 200) kHz (2.5 to 5) Hz (5 to 10) Hz 10 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 200) kHz 0.12 dB 0.14 dB 0.093 dB 0.039 dB 0.019 dB 0.019 dB 0.022 dB 0.062 dB 0.39 dB 0.13 dB 0.070 dB 0.053 dB 0.053 dB 0.055 dB 0.091 dB 0.39 dB Signal generator (SRS DS360) LP filter & 40 db Attn with ADP090 used for preamplifer input 1/3 octave intervals 1/12 octave intervals 1/3 octave intervals 1/12 octave intervals
0.01 to 14 V
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3622.01) Revised 03/05/2026 Page 4 of 5 III. Mechanical Parameter/Equipment Frequency CMC2, 3 (±) Comments Accelerometers – vs. Primary Standard (5 to 9) Hz (10 to 99) Hz 100 Hz (101 to 920) Hz (921 to 5000) Hz (5001 to 10 000) Hz (10 to 15) kHz (15 to 20) kHz 2.0 % 1.5 % 1.2 % 1.4 % 1.7 % 2.2 % 2.5 % 3.5 % Data acquisition card w/ 396C10/C11 air bearing shaker Low Frequency Accelerometer Calibration (0.5 to 10) Hz 1.2 % Data acquisition card w/ low frequency long stroke shaker w/ optical reference IV. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measure 100 mV to 120 V (3 to 40) Hz 40 Hz to 200 kHz 36 µHz/Hz + 13 mHz 33 µHz/Hz + 13 mHz Agilent (HP) 34401A digital multimeter Frequency – Measuring Equipment 10 µVpp to 40 Vpp 0.01 Hz to 200 kHz 12 µHz/Hz + 12 mHz Signal generator (SRS DS360)  1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3622.01) Revised 03/05/2026 Page 5 of 5 3 The measurands stated are generated using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. 4 All references to dB are given in dB Volts. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
6ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.