Larson Davis a PCB Division
1681 West 820 North, 84601, Provo, UT, United States
Visit website- Scope lines
- 6
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 3622.01 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3622.01) Revised 03/05/2026 Page 2 of 5
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
DC Voltage – Measure
(10 to 120) mV
100 mV to 1.2 V
(1 to 12) V
(10 to 120) V
7.5 µV/V + 0.36 µV
9.2 µV/V + 0.32 µV
9.4 µV/V + 0.87 µV
12 µV/V + 32 µV
Agilent 3458A digital
multimeter
Parameter/Range
Frequency
CMC2, 3, 4 (±)
Comments
AC Voltage – Measure
100 mV to 14 V
(10 to 120) mV
100 mV to 1.2 V
(1 to 12) V
(10 to 120) V
6.3 Hz to 20 kHz
3 Hz to 50 kHz
(50 to 300) kHz
3 Hz to 50 kHz
(50 to 300) kHz
3 Hz to 50 kHz
(50 to 300) kHz
3 Hz to 50 kHz
(50 to 300) kHz
0.12 dB
0.031 % + 2.1 µV
0.31 % + 11 µV
0.031 % + 21 µV
0.31 % + 0.11 mV
0.031 % + 0.21 mV
0.31 % + 1.1 mV
0.036 % + 2.1 mV
0.41 % + 11 mV
LD model 831 with
ADP074
Agilent 3458A digital
multimeter
Attenuation – Measure,
Fixed Points
40 dB
60 dB Gain
10 Hz to 20 kHz
10 Hz to 20 kHz
0.02 dB
0.05 dB
Agilent (HP) 34401A
digital multimeter | ||
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3622.01) Revised 03/05/2026 Page 3 of 5
Parameter/Range
Frequency
CMC2, 3, 4 (±)
Comments
AC Voltage – Generate
Sinewave:
10 mV to 14 V
30 mV to 3 V
(0.1 to 30) mV
16 µV to 0.1 mV
0.01 Hz to 200 kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 126) kHz
10 Hz to 20 kHz
10 Hz to 20 kHz
1.3 % + 1.2 µV
0.12 dB
0.06 dB
0.04 dB
0.04 dB
0.09 dB
0.50 dB
0.04 dB
0.04 dB
Signal generator
(SRS DS360)
Signal generator
(LD 2900 with 2209 or
2239)
Preamplifier & Sound
Level Meter –
(103 to 142) dBµV
141 mV to 12.6 V
(24 to 103) dBµV
15.9 µV to 141 mV
(103 to 142) dBµV
141 mV to 12.6 V
(24 to 103) dBµV
15.9 µV to 141 mV
3 Hz to 20 kHz
3 Hz to 20 kHz
(2.5 to 5) Hz
(5 to 10) Hz
10 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(2.5 to 5) Hz
(5 to 10) Hz
10 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
0.12 dB
0.14 dB
0.093 dB
0.039 dB
0.019 dB
0.019 dB
0.022 dB
0.062 dB
0.39 dB
0.13 dB
0.070 dB
0.053 dB
0.053 dB
0.055 dB
0.091 dB
0.39 dB
Signal generator
(SRS DS360) LP filter
& 40 db Attn with
ADP090 used for
preamplifer input
1/3 octave intervals
1/12 octave intervals
1/3 octave intervals
1/12 octave intervals | 0.01 to 14 V |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3622.01) Revised 03/05/2026 Page 4 of 5
III. Mechanical
Parameter/Equipment
Frequency
CMC2, 3 (±)
Comments
Accelerometers –
vs. Primary Standard
(5 to 9) Hz
(10 to 99) Hz
100 Hz
(101 to 920) Hz
(921 to 5000) Hz
(5001 to 10 000) Hz
(10 to 15) kHz
(15 to 20) kHz
2.0 %
1.5 %
1.2 %
1.4 %
1.7 %
2.2 %
2.5 %
3.5 %
Data acquisition card
w/ 396C10/C11 air
bearing shaker
Low Frequency
Accelerometer Calibration
(0.5 to 10) Hz
1.2 %
Data acquisition card
w/ low frequency long
stroke shaker w/
optical reference
IV. Time & Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Frequency – Measure
100 mV to 120 V
(3 to 40) Hz
40 Hz to 200 kHz
36 µHz/Hz + 13 mHz
33 µHz/Hz + 13 mHz
Agilent (HP) 34401A
digital multimeter
Frequency – Measuring
Equipment
10 µVpp to 40 Vpp
0.01 Hz to 200 kHz
12 µHz/Hz + 12 mHz
Signal generator
(SRS DS360)
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3622.01) Revised 03/05/2026 Page 5 of 5
3 The measurands stated are generated using the indicated instrument (see Comments). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges indicated.
CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading
plus a fixed floor specification.
4 All references to dB are given in dB Volts.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 6 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- SIMCO Electronics - Salt Lake CityDraper, UT · ~37 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Western States CalibrationSalt Lake City, UT · ~62 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Sensor CalibrationsKaysville, UT · ~92 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - DenverLongmont, CO · ~557 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- BHD Test & MeasurementThornton, CO · ~569 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.