The L.S. Starrett Company, Tru-Stone Technologies Division

1101 Prosper Drive, P.O. Box 430, 56387, Waite Park, MN, United States

Visit website
A2LA 1580.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 1580.01 · 3 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 480 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1580.01) 11/13/2025 Page 2 of 2 Parameter/Equipment Range CMC2, 3 (±) Comments Granite Metrology Accessories – Flatness/Straightness Perpendicularity/ Parallelism Parallelism Repeat Reading (Flatness of Local Area) Up to ±0.0004 in (12 to 300) in (diagonal) (12 to 480) in (diagonal) Up to 48 in Up to 0.0003 in (>0.0003 to 0.001) in (12 to 480) in (length) Up to 0.002 in 18 μin (4.6√D) μin (29√D) μin 8 μin/in 20 μin 67 μin (11√D) μin 28 μin Mikrokator Autocollimator Electronic level Pentaprism and autocollimator Electronic amp and gage head Electronic level Repeat-o-meter with 0.000 02 in indicator ___________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, D is the length of the diagonal in inches. 4 This scope meets the P112 Flexible Scope Policy.
12 to 480 in
3ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1101 Prosper Drive, P.O. Box 430, Waite Park, MN, 56387, US

45.55371, -94.23346

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.