The L.S. Starrett Company, Tru-Stone Technologies Division
1101 Prosper Drive, P.O. Box 430, 56387, Waite Park, MN, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 1580.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 480 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1580.01) 11/13/2025 Page 2 of 2
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Granite Metrology
Accessories –
Flatness/Straightness
Perpendicularity/
Parallelism
Parallelism
Repeat Reading
(Flatness of Local
Area)
Up to ±0.0004 in
(12 to 300) in (diagonal)
(12 to 480) in (diagonal)
Up to 48 in
Up to 0.0003 in
(>0.0003 to 0.001) in
(12 to 480) in (length)
Up to 0.002 in
18 μin
(4.6√D) μin
(29√D) μin
8 μin/in
20 μin
67 μin
(11√D) μin
28 μin
Mikrokator
Autocollimator
Electronic level
Pentaprism and
autocollimator
Electronic amp and
gage head
Electronic level
Repeat-o-meter with
0.000 02 in indicator
___________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, D is the length of the diagonal in inches.
4 This scope meets the P112 Flexible Scope Policy. | 12 to 480 in |
| 3 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- PRECISION REPAIR AND CALIBRATIONSBlaine, MN · ~89 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - MinneapolisBloomington, MN · ~107 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- United StandardsBloomington, MN · ~107 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Team TorqueBismarck, ND · ~523 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - ROCKFORDRockford, IL · ~557 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.