CIE
15030 23 Mile rd, 48315, Shelby Township, MI, United States
- Accredited standards
- 1
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ASTM D523Standard Test Method for Specular Gloss
ASTM D523; ISO/IEC 17025:2017 CIE 15030 23; IEC 17025
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-06.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active6815.01
The scope document we hold says it is valid until 2026-11-30.
Accredited scope, certificate 6815.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM D523; ISO/IEC 17025:2017 CIE 15030 23; IEC 17025 | automotive interior components | -45 to 170 °C |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6815.01) 11/20/2024 Page 2 of 2
Dimensional Testing2:
Parameter/Equipment Range CMC3 (±) Technique/Method
Length4 (1D)
Length
4 (3D)
Up to 8 inches
X 157.48 inches
Y 62.99 inches
Z 82.67 inches
570µin
.005mm
.004mm
.006 mm
Digital Calipers
CMM – Hexagon 60524
1 Also testing to customer supplied specifications within the parameters listed above.
2 This laboratory offers commercial dimensional testing service only.
3 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing routine calibrations of
nearly ideal measurement standards of nearly ideal m easuring equipment. CMC’s represent expanded
uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of
k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be
greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
4 This test is not equivalent to that of a calibration. | to 8 inches |
| 3 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Michigan Testing InstituteSterling Heights, MI · ~11 kmA2LAShares 1 accredited test methodASTM D523
- Ghesquiere Plastic TestingHarper Woods, MI · ~27 kmA2LAShares 1 accredited test methodASTM D523
- Intertek Testing Services NAPlymouth Township, MI · ~54 kmA2LAShares 1 accredited test methodASTM D523
- Technical Finishing, Inc. - TestFlint, MI · ~70 kmA2LAShares 1 accredited test methodASTM D523
- National Exposure TestingSylvania, OH · ~122 kmA2LAShares 1 accredited test methodASTM D523
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.