InvoCal
15577 SHEADS Mountain ROAD, 22737-2350, Rixeyville, VA, United States
Visit website- Scope lines
- 11
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 11 scope lines.
A2LA certificate 6782.01 · 11 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6782.01) 8/5/2024 Page 2 of 10
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Current – Measure3
(0 to 100) nA
(0.1 to 1) µA
(1 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
0.21 mA/A + 0.04 nA
59 µA/A + 0.4 nA
27 µA/A + 0.1 nA
26 µA/A + 0.8 nA
26 µA/A + 5 pA
26 µA/A + 50 pA
46 µA/A + 0.5 µA
0.18 µA/A + 10 µA
HP 3458A
DC Resistance –
Generate3
(0 to 10.999) Ω
(11 to 32.999) Ω
(33 to 109.999) Ω
(110 to 329.999) kΩ
(0.33 to 1.0999) kΩ
(1.1 to 3.2999) kΩ
(3.3 to 109.999) kΩ
(110 to 329.999) kΩ
(0.33 to 1.0999) MΩ
(1.1 k to 3.2999) MΩ
(3.3 to 10.999) MΩ
(11 to 32.999) MΩ
(33 to 109.999) MΩ
(110 to 329.999) MΩ
(330 to 1100) MΩ
55 µΩ/Ω + 1 mΩ
42 µΩ/Ω + 1.5 mΩ
94 µΩ/Ω + 1.4 mΩ
34 µΩ/Ω + 2 mΩ
34 µΩ/Ω + 2 mΩ
37 µΩ/Ω + 20 mΩ
19 µΩ/Ω + 20 mΩ
37 µΩ/Ω + 200 mΩ
37 µΩ/Ω + 200 mΩ
40 µΩ/Ω + 2 Ω
39 µΩ/Ω + 2 Ω
73 µΩ/Ω + 30 Ω
51 µΩ/Ω + 50 Ω
0.32 mΩ/Ω + 2.5 kΩ
0.57 mΩ/Ω + 3 kΩ
Fluke 5522A
DC Resistance –
Measure3
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 10) GΩ
49 µΩ/Ω + 50 µΩ
17 µΩ/Ω + 500 µΩ
15 µΩ/Ω + 500 µΩ
14 µΩ/Ω + 500 µΩ
14 µΩ/Ω + 5.0 µΩ
20 µΩ/Ω + 50 µΩ
66 µΩ/Ω + 1.0 Ω
3.4 µΩ/Ω + 100 Ω
6.5 µΩ/Ω + 10 kΩ
HP 3458A
Electrical Calibration of
Thermocouples &
Indicators3 –
Type J
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
0.22 °C
0.14 °C
0.12 °C
0.14 °C
0.19 °C
Fluke 5522A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6782.01) 8/5/2024 Page 3 of 10
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouples &
Indicators3 – (cont)
Type K
Type T
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.26 °C
0.15 °C
0.13 °C
0.21 °C
0.33 °C
0.49 °C
0.19 °C
0.14 °C
0.15 °C
Fluke 5522A
Electrical Calibration of
RTD Indicators3 –
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.068 °C
0.055 °C
0.07 °C
0.098 °C
0.11 °C
0.18 °C
0.039 °C
0.055 °C
0.07 °C
0.078 °C
0.093 °C
0.2 °C
0.032 °C
0.039 °C
0.076 °C
0.073 °C
0.084 °C
0.09 °C
0.096 °C
0.18 °C
Fluke 5522A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6782.01) 8/5/2024 Page 4 of 10
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicators3 –
(cont)
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
PtNi 385, 120 Ω
Cu 427, 10 Ω
(-200 to -80) °C
(-80 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 100) °C
(100 to 260) °C
(260 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.032 °C
0.032 °C
0.039 °C
0.093 °C
0.11 °C
0.11 °C
0.12 °C
0.032 °C
0.039 °C
0.047 °C
0.062 °C
0.07 °C
0.086 °C
0.024 °C
0.032 °C
0.039 °C
0.062 °C
0.062 °C
0.11 °C
0.23 °C
Fluke 5522A
Oscilloscope3 –
DC Signal
50 Ω Load
1 MΩ Load
Square Wave
50 Ω Load
10 Hz to 10 kHz
1 MΩ Load
10 Hz to 10 kHz
(0 to 6.6) V
(0 to 130) V
(0.001 to 6.6) V
p-p
(0 to 130) V
0.16 % of output + 2.3 mV
0.035 % of output + 5 mV
0.39 % of output + 2.5 mV
0.03 % of output + 0.15 V
Fluke 5522A/SC1100 | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6782.01) 8/5/2024 Page 5 of 10
Parameter/Equipment
Range
CMC2 (±)
Comments
Oscilloscope3 – (cont)
Level Sine Wave:
Amplitude
50 kHz Reference
Flatness
50 kHz Reference
Time Markers
Source & Period
Into a 50 Ω Load
Amplitude:
1 MΩ
50 Ω
Frequency
50 kHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
5 s to 50 ms
20 ms to 2 ns
1.8 mV to 55 V
(pk-pk)
1.8 mV to 2.5 V(pk-pk)
10 Hz to 100 kHz
1.6 % + 0.3 mV
2.8 % + 0.3 mV
3.2 % + 0.3 mV
4.7 % + 0.3 mV
5.7 % + 0.3 mV
1.4 % + 0.1 mV
1.6 % + 0.1 mV
3.2 % + 0.1 mV
3.9 % + 0.1 mV
160 µs + t parts in 10
6 s
64 µs + t parts in 106 s
2.4 % + 0.1 mV
2.4 % + 0.1 mV
34 parts in 10
6 Hz + 15 mHz
Fluke
5522A/SC1100
t = time in seconds | to 1100 MHz |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6782.01) 8/5/2024 Page 6 of 10
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 30) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.064 % + 6 µV
0.012 % + 6 µV
0.016 % + 6 µV
0.078 % + 6 µV
0.27 % + 6 µV
0.62 % + 6 µV
0.023 % + 8 µV
0.011 % + 8 µV
0.012 % + 8 µV
0.027 % + 8 µV
0.062 % + 32 µV
0.16 % + 70 µV
0.023 % + 50 µV
0.012 % + 60 µV
0.018 % + 60 µV
0.027 % + 50 µV
0.059 % + 130 µV
0.22 % + 600 µV
0.54 % + 0.65 mV
0.026 % + 0.6 mV
0.11 % + 0.6 mV
0.15 % + 0.6 mV
0.17 % + 1.6 mV
0.23 % + 2 mV
0.23 % + 6 mV
0.24 % + 6 mV
0.40 % + 6 mV
0.43 % + 6 mV
0.41 % + 10 mV
0.41 % + 10 mV
0.40 % + 10 mV
Fluke 5522A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6782.01) 8/5/2024 Page 7 of 10
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure3
(0 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(10 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.039 % + 3 µV
0.023 % + 1.1 µV
0.034 % + 1.1 µV
0.11 % + 1.1 µV
0.57 % + 1.1 µV
4.5 % + 2 µV
0.049 % + 4 µV
0.12 % + 2 µV
0.045 % + 2 µV
0.091 % + 2 µV
0.12 % + 2 µV
0.35 % + 10 µV
0.008 % + 40 µV
0.008 % + 20 µV
0.016 % + 20 µV
0.034 % + 20 µV
0.091 % + 20 µV
0.34 % + 100 µV
0.043 % + 400 µV
0.027 % + 200 µV
0.023 % + 200 µV
0.041 % + 200 µV
0.094 % + 200 µV
0.34 % + 1 mV
0.21 % + 4 mV
0.21 % + 4 mV
0.21 % + 4 mV
0.28 % + 2 mV
0.31 % + 2 mV
1.6 % + 40 mV
1.7 % + 20 mV
2.3 % + 20 mV
2.3 % + 20 mV
0.36 % + 20 mV
HP 3458A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6782.01) 8/5/2024 Page 8 of 10
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Capacitance – Generate3
(0.22 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.0999) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.2999) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(10 to 50) Hz
(10 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.55 % + 0.01 nF
0.42 % + 0.01 nF
0.43 % + 0.01 nF
0.19 % + 0.01 nF
0.19 % + 0.1 nF
0.19 % + 0.1 nF
0.19 % + 0.3 nF
0.19 % + 1 nF
0.19 % + 3 nF
0.19 % + 10 nF
0.31 % + 30 nF
0.36 % + 100 nF
0.35 % + 300 nF
0.35 % + 1 µF
0.35 % + 3 µF
0.35 % + 10 µF
0.58 % + 30 µF
0.85 % + 100 µF
Fluke 5522A
AC Current – Generate3
(29 to 329.99) µA
(0.33 to 3.2999) mA
(3.3 to 32.999) mA
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.16 % + 100 nA
0.097 % + 100 nA
0.23 % + 150 nA
0.62 % + 200 nA
1.2 % + 400 nA
0.16 % + 150 nA
0.078 % + 150 nA
0.16 % + 200 nA
0.39 % + 300 nA
0.78 % + 600 nA
0.14 % + 2 µA
0.10 % + 2 µA
0.062 % + 2 µA
0.16 % + 3 µA
1.1 % + 4 µA
Fluke 5522A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6782.01) 8/5/2024 Page 9 of 10
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(cont)
(33 to 329.99) mA
(0.33 to 1.099 99) A
(1.1 to 2.9999) A
(3 to 10.999) A
(11 to 20.5) A
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
(0.100 to 1) kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.14 % + 20 µA
0.032 % + 20 µA
0.078 % + 50 µA
0.16 % + 100 µA
0.31 % + 200 µA
0.14 % + 100 µA
0.04 % + 100 µA
0.47 % + 1 mA
1.9 % + 5 mA
0.21 % + 100 µA
0.13 % + 100 µA
0.14 % + 1 mA
2 % + 5 mA
0.31 % + 2 mA
0.31 % + 2 mA
2.4 % + 2 mA
0.12 % + 5 mA
0.15 % + 5 mA
3 % + 5 mA
Fluke 5522A
AC Current – Measure3
Up to 100 µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
40 Hz to 5 kHz
0.071 % + 31 nA
0.036 % + 0.21 µA
0.036 % + 2.1 µA
0.036 % + 21 µA
0.12 % + 0.21 mA
HP 3458A
_____________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the
laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration. | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6782.01) 8/5/2024 Page 10 of 10
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the Calibration and
Measurement Capability Uncertainty (CMC) found on t he A2LA Scope. Allowance must be made for
aspects such as the environment at the place of calibration and for other possible adverse effects such as
those caused by transportation of the calibration equipment. The usual allowance for the uncertainty
introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own,
could result in the actual measurement uncertainty achievable on a customer’s site being larger than the
CMC
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent
or fraction of the reading plus a fixed floor specification.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 11 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- SIMCO Electronics - Washington D.C.Sterling, VA · ~68 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Automated PrecisionRockville, MD · ~91 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Electrical Test InstrumentsFrederick, MD · ~105 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- TRESCAL, INC. - Richmond, VAProvidence Forge, VA · ~151 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- American Scale & EquipmentBaltimore, MD · ~155 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.