InvoCal

15577 SHEADS Mountain ROAD, 22737-2350, Rixeyville, VA, United States

Visit website
A2LA 6782.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
11
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 11 scope lines.

A2LA certificate 6782.01 · 11 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6782.01) 8/5/2024 Page 2 of 10 Parameter/Equipment Range CMC2, 4 (±) Comments DC Current – Measure3 (0 to 100) nA (0.1 to 1) µA (1 to 10) µA (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 0.21 mA/A + 0.04 nA 59 µA/A + 0.4 nA 27 µA/A + 0.1 nA 26 µA/A + 0.8 nA 26 µA/A + 5 pA 26 µA/A + 50 pA 46 µA/A + 0.5 µA 0.18 µA/A + 10 µA HP 3458A DC Resistance – Generate3 (0 to 10.999) Ω (11 to 32.999) Ω (33 to 109.999) Ω (110 to 329.999) kΩ (0.33 to 1.0999) kΩ (1.1 to 3.2999) kΩ (3.3 to 109.999) kΩ (110 to 329.999) kΩ (0.33 to 1.0999) MΩ (1.1 k to 3.2999) MΩ (3.3 to 10.999) MΩ (11 to 32.999) MΩ (33 to 109.999) MΩ (110 to 329.999) MΩ (330 to 1100) MΩ 55 µΩ/Ω + 1 mΩ 42 µΩ/Ω + 1.5 mΩ 94 µΩ/Ω + 1.4 mΩ 34 µΩ/Ω + 2 mΩ 34 µΩ/Ω + 2 mΩ 37 µΩ/Ω + 20 mΩ 19 µΩ/Ω + 20 mΩ 37 µΩ/Ω + 200 mΩ 37 µΩ/Ω + 200 mΩ 40 µΩ/Ω + 2 Ω 39 µΩ/Ω + 2 Ω 73 µΩ/Ω + 30 Ω 51 µΩ/Ω + 50 Ω 0.32 mΩ/Ω + 2.5 kΩ 0.57 mΩ/Ω + 3 kΩ Fluke 5522A DC Resistance – Measure3 (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 10) GΩ 49 µΩ/Ω + 50 µΩ 17 µΩ/Ω + 500 µΩ 15 µΩ/Ω + 500 µΩ 14 µΩ/Ω + 500 µΩ 14 µΩ/Ω + 5.0 µΩ 20 µΩ/Ω + 50 µΩ 66 µΩ/Ω + 1.0 Ω 3.4 µΩ/Ω + 100 Ω 6.5 µΩ/Ω + 10 kΩ HP 3458A Electrical Calibration of Thermocouples & Indicators3 – Type J (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C 0.22 °C 0.14 °C 0.12 °C 0.14 °C 0.19 °C Fluke 5522A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6782.01) 8/5/2024 Page 3 of 10 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouples & Indicators3 – (cont) Type K Type T (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.26 °C 0.15 °C 0.13 °C 0.21 °C 0.33 °C 0.49 °C 0.19 °C 0.14 °C 0.15 °C Fluke 5522A Electrical Calibration of RTD Indicators3 – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.068 °C 0.055 °C 0.07 °C 0.098 °C 0.11 °C 0.18 °C 0.039 °C 0.055 °C 0.07 °C 0.078 °C 0.093 °C 0.2 °C 0.032 °C 0.039 °C 0.076 °C 0.073 °C 0.084 °C 0.09 °C 0.096 °C 0.18 °C Fluke 5522A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6782.01) 8/5/2024 Page 4 of 10 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicators3 – (cont) Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω PtNi 385, 120 Ω Cu 427, 10 Ω (-200 to -80) °C (-80 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 100) °C (100 to 260) °C (260 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 260) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-100 to 260) °C 0.032 °C 0.032 °C 0.039 °C 0.093 °C 0.11 °C 0.11 °C 0.12 °C 0.032 °C 0.039 °C 0.047 °C 0.062 °C 0.07 °C 0.086 °C 0.024 °C 0.032 °C 0.039 °C 0.062 °C 0.062 °C 0.11 °C 0.23 °C Fluke 5522A Oscilloscope3 – DC Signal 50 Ω Load 1 MΩ Load Square Wave 50 Ω Load 10 Hz to 10 kHz 1 MΩ Load 10 Hz to 10 kHz (0 to 6.6) V (0 to 130) V (0.001 to 6.6) V p-p (0 to 130) V 0.16 % of output + 2.3 mV 0.035 % of output + 5 mV 0.39 % of output + 2.5 mV 0.03 % of output + 0.15 V Fluke 5522A/SC1100
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6782.01) 8/5/2024 Page 5 of 10 Parameter/Equipment Range CMC2 (±) Comments Oscilloscope3 – (cont) Level Sine Wave: Amplitude 50 kHz Reference Flatness 50 kHz Reference Time Markers Source & Period Into a 50 Ω Load Amplitude: 1 MΩ 50 Ω Frequency 50 kHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 5 s to 50 ms 20 ms to 2 ns 1.8 mV to 55 V (pk-pk) 1.8 mV to 2.5 V(pk-pk) 10 Hz to 100 kHz 1.6 % + 0.3 mV 2.8 % + 0.3 mV 3.2 % + 0.3 mV 4.7 % + 0.3 mV 5.7 % + 0.3 mV 1.4 % + 0.1 mV 1.6 % + 0.1 mV 3.2 % + 0.1 mV 3.9 % + 0.1 mV 160 µs + t parts in 10 6 s 64 µs + t parts in 106 s 2.4 % + 0.1 mV 2.4 % + 0.1 mV 34 parts in 10 6 Hz + 15 mHz Fluke 5522A/SC1100 t = time in seconds
to 1100 MHz
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6782.01) 8/5/2024 Page 6 of 10 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 30) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.064 % + 6 µV 0.012 % + 6 µV 0.016 % + 6 µV 0.078 % + 6 µV 0.27 % + 6 µV 0.62 % + 6 µV 0.023 % + 8 µV 0.011 % + 8 µV 0.012 % + 8 µV 0.027 % + 8 µV 0.062 % + 32 µV 0.16 % + 70 µV 0.023 % + 50 µV 0.012 % + 60 µV 0.018 % + 60 µV 0.027 % + 50 µV 0.059 % + 130 µV 0.22 % + 600 µV 0.54 % + 0.65 mV 0.026 % + 0.6 mV 0.11 % + 0.6 mV 0.15 % + 0.6 mV 0.17 % + 1.6 mV 0.23 % + 2 mV 0.23 % + 6 mV 0.24 % + 6 mV 0.40 % + 6 mV 0.43 % + 6 mV 0.41 % + 10 mV 0.41 % + 10 mV 0.40 % + 10 mV Fluke 5522A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6782.01) 8/5/2024 Page 7 of 10 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure3 (0 to 10) mV (10 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (10 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.039 % + 3 µV 0.023 % + 1.1 µV 0.034 % + 1.1 µV 0.11 % + 1.1 µV 0.57 % + 1.1 µV 4.5 % + 2 µV 0.049 % + 4 µV 0.12 % + 2 µV 0.045 % + 2 µV 0.091 % + 2 µV 0.12 % + 2 µV 0.35 % + 10 µV 0.008 % + 40 µV 0.008 % + 20 µV 0.016 % + 20 µV 0.034 % + 20 µV 0.091 % + 20 µV 0.34 % + 100 µV 0.043 % + 400 µV 0.027 % + 200 µV 0.023 % + 200 µV 0.041 % + 200 µV 0.094 % + 200 µV 0.34 % + 1 mV 0.21 % + 4 mV 0.21 % + 4 mV 0.21 % + 4 mV 0.28 % + 2 mV 0.31 % + 2 mV 1.6 % + 40 mV 1.7 % + 20 mV 2.3 % + 20 mV 2.3 % + 20 mV 0.36 % + 20 mV HP 3458A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6782.01) 8/5/2024 Page 8 of 10 Parameter/Range Frequency CMC2, 4 (±) Comments Capacitance – Generate3 (0.22 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.0999) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (10 to 50) Hz (10 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.55 % + 0.01 nF 0.42 % + 0.01 nF 0.43 % + 0.01 nF 0.19 % + 0.01 nF 0.19 % + 0.1 nF 0.19 % + 0.1 nF 0.19 % + 0.3 nF 0.19 % + 1 nF 0.19 % + 3 nF 0.19 % + 10 nF 0.31 % + 30 nF 0.36 % + 100 nF 0.35 % + 300 nF 0.35 % + 1 µF 0.35 % + 3 µF 0.35 % + 10 µF 0.58 % + 30 µF 0.85 % + 100 µF Fluke 5522A AC Current – Generate3 (29 to 329.99) µA (0.33 to 3.2999) mA (3.3 to 32.999) mA (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.16 % + 100 nA 0.097 % + 100 nA 0.23 % + 150 nA 0.62 % + 200 nA 1.2 % + 400 nA 0.16 % + 150 nA 0.078 % + 150 nA 0.16 % + 200 nA 0.39 % + 300 nA 0.78 % + 600 nA 0.14 % + 2 µA 0.10 % + 2 µA 0.062 % + 2 µA 0.16 % + 3 µA 1.1 % + 4 µA Fluke 5522A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6782.01) 8/5/2024 Page 9 of 10 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (cont) (33 to 329.99) mA (0.33 to 1.099 99) A (1.1 to 2.9999) A (3 to 10.999) A (11 to 20.5) A (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (0.100 to 1) kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 0.14 % + 20 µA 0.032 % + 20 µA 0.078 % + 50 µA 0.16 % + 100 µA 0.31 % + 200 µA 0.14 % + 100 µA 0.04 % + 100 µA 0.47 % + 1 mA 1.9 % + 5 mA 0.21 % + 100 µA 0.13 % + 100 µA 0.14 % + 1 mA 2 % + 5 mA 0.31 % + 2 mA 0.31 % + 2 mA 2.4 % + 2 mA 0.12 % + 5 mA 0.15 % + 5 mA 3 % + 5 mA Fluke 5522A AC Current – Measure3 Up to 100 µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 40 Hz to 5 kHz 0.071 % + 31 nA 0.036 % + 0.21 µA 0.036 % + 2.1 µA 0.036 % + 21 µA 0.12 % + 0.21 mA HP 3458A _____________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6782.01) 8/5/2024 Page 10 of 10 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on t he A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
11ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.