TRESCAL, INC. - Richmond, VA
6540 Emmaus Church Road Suite 106, 23140, Providence Forge, VA, United States
Visit website- Scope lines
- 15
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 15 scope lines.
A2LA certificate 1486.02 · 15 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 12 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 2 of 14
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
DC Voltage – Generate3
(0 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
0.8 µV + 16 nV/mV
17 µV + 5 µV/V
88 µV + 7 µV/V
0.56 mV + 14 µV/V
2.7 mV + 14 µV/V
Fluke 5522A
DC Voltage – Measure3
Up to 100 mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 20) kV
(20 to 35) kV
(35 to 40) kV
0.33 µV + 17 µV/V
0.52 µV + 8 µV/V
8.8 µV + 8.1 µV/V
35 µV + 10 µV/V
0.2 mV + 12 µV/V
2.3 %
1.2 %
2.3 %
HP 3458A
Fluke 80K-40 probe
& HP 3458A
DC Current – Generate3
Clamp-On Ammeters
Up to 330 µA
330 µA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 1.1 A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(3.2 to 200) A
(16 to 1000) A
16 nA + 0.12 nA/µA
41 nA + 80 nA/mA
0.21 µA + 80 nA/mA
2.1 µA + 80 nA/mA
33 µA + 0.16 mA/A
0.37 mA + 0.13 mA/A
0.49 mA + 0.39 mA/A
9.4 mA + 0.8 mA/A
7.5 mA + 2.6 mA/A
37 mA + 2.6 mA/A
Fluke 5522A
5520A w/:
10-turn coil
50-turn coil
DC Current – Measure3
(0 to 100) nA
(0.1 to 1) µA
(1 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
41 pA + 89 µA/A
41 pA + 24 pA/µA
40 pA + 24 pA/µA
82 pA + 22 pA/µA
6 nA + 24 nA/mA
53 nA + 21 nA/mA
0.53 µA + 37 nA/mA
10 µA + 0.11 mA/A
HP 3458A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 3 of 14
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Capacitance – Generate3
(0.19 to 0.3999) nF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
9 pF + 4 pF/nF
10 pF + 4 pF/nF
13 pF + 4 pF/nF
15 pF + 2 pF/nF
0.1 nF + 2 pF/nF
0.15 nF + 2 pF/nF
0.5 nF + 2 pF/nF
1.5 nF + 2 nF/µF
5 nF + 2 nF/µF
14 nF + 2 nF/µF
60 nF + 3 nF/µF
0.2 µF + 4 nF/µF
0.63 µF + 4 nF/µF
2 µF + 4 µF/mF
7 µF + 4 µF/mF
38 µF + 2.5 µF/mF
90 µF + 6 µF/mF
Fluke 5522A
DC Resistance – Generate3
(0 to 10.9999) Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(330 to 1099.999) Ω
(1.1 to 3.299 999) kΩ
(33 to 10.999 99) kΩ
(1 to 32.999 99) kΩ
(33 to 109.999) kΩ
(110 to 329.999) kΩ
(0.33 to 1.099 99) MΩ
(1.1 to 3.299 00) MΩ
(3.3 to 10.9999) MΩ
(11 to 32.9999) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
1.2 mΩ + 24 µΩ/Ω
1.5 mΩ + 24 µΩ/Ω
1.9 mΩ + 22 µΩ/Ω
4.1 mΩ + 22 µΩ/Ω
9.1 mΩ + 22 µΩ/Ω
41 mΩ + 22 µΩ/Ω
92 mΩ + 22 µΩ/Ω
0.41 Ω + 22 µΩ/Ω
0.9 Ω + 22 µΩ/Ω
8.4 Ω + 26 µΩ/Ω
14 Ω + 26 µΩ/Ω
93 Ω + 48 µΩ/Ω
0.4 kΩ + 0.1 mΩ/Ω
4.4 kΩ + 0.2 mΩ/Ω
16 kΩ + 0.4 mΩ/Ω
0.35 MΩ + 2.4 mΩ/Ω
4.4 MΩ + 12 mΩ/Ω
Fluke 5522A
Resistance – Measure3
(0 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
55 µΩ + 15 µΩ/Ω
0.52 mΩ + 13 µΩ/Ω
0.53 mΩ + 10 µΩ/Ω
5.3 mΩ + 10 µΩ/Ω
53 mΩ + 11 µΩ/Ω
2.3 Ω + 17 µΩ/Ω
0.1 kΩ + 55 µΩ/Ω
1 kΩ + 0.52 mΩ/Ω
10 kΩ + 5.1 mΩ/Ω
HP 3458A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 4 of 14
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicators3 –
Pt 385, 100 Ω
Field Calibration3
Pt 3926, 100 Ω
Field Calibration
3
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to 100) °C
(100 to 300) °C
(300 to 600) °C
(600 to 800) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to 100) °C
(100 to 300) °C
(300 to 630) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to 0) °C
(> 0 to 100) °C
(> 100 to 260) °C
(> 260 to 300) °C
(> 300 to 400) °C
(> 400 to 600) °C
(> 600 to 630) °C
(-200 to -80) °C
(> -80 to 100) °C
(> 100 to 260) °C
(> 260 to 400) °C
(> 400 to 600) °C
(> 600 to 630) °C
0.042 °C
0.041 °C
0.057 °C
0.073 °C
0.081 °C
0.097 °C
0.19 °C
0.19 °C
0.31 °C
0.44 °C
0.57 °C
0.041 °C
0.041 °C
0.057 °C
0.073 °C
0.081 °C
0.097 °C
0.19 °C
0.31 °C
0.44 °C
0.033 °C
0.042 °C
0.049 °C
0.065 °C
0.073 °C
0.19 °C
0.034 °C
0.033 °C
0.042 °C
0.097 °C
0.11 °C
0.11 °C
0.13 °C
0.034 °C
0.042 °C
0.05 °C
0.065 °C
0.073 °C
0.089 °C
Fluke 5522A
Fluke 726
Fluke 5522A
Fluke 726
Fluke 5522A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 5 of 14
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicators3 – (cont)
Pt 385, 1 kΩ
PtNi 385, 120 Ω
Cu427.10 Ω
(-200 to 0) °C
(> 0 to 100) °C
(> 100 to 260) °C
(> 260 to 300) °C
(> 300 to 600) °C
(> 600 to 630) °C
(-80 to 100) °C
(> 100 to 260) °C
(-100 to 260) °C
0.026 °C
0.033 °C
0.042 °C
0.049 °C
0.057 °C
0.19 °C
0.066 °C
0.11 °C
0.24 °C
Fluke 5522A
Electrical Calibration of
Thermocouple Indicators –
Type E
Field Calibration
3
Type J
Field Calibration
3
Type K
Field Calibration
3
Type T
Field Calibration
3
(-200 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-250 to -100) °C
(-100 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-250 to -100) °C
(-100 to 1000) °C
(-100 to 1000) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to 0) °C
(0 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
(-250 to 0) °C
(0 to 400) °C
0.4 ᵒC
0.13 ᵒC
0.11 ᵒC
0.13 ᵒC
0.17 ᵒC
0.8 °C
0.53 °C
0.22 ᵒC
0.13 ᵒC
0.11 ᵒC
0.14 ᵒC
0.18 ᵒC
0.53 °C
0.27 °C
0.4 °C
0.27 ᵒC
0.14 ᵒC
0.13 ᵒC
0.21 ᵒC
0.32 ᵒC
0.8 °C
0.4 °C
0.67 °C
0.51 ᵒC
0.21 ᵒC
0.15 ᵒC
0.13 C
0.8 °C
0.27 °C
Fluke 5522A
Fluke 726
Fluke 5522A
Fluke 726
Fluke 5522A
Fluke 726
Fluke 5522A
Fluke 726 | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 6 of 14
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
(1 to 33) mV
(33 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 200) kHz
(200 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 10 kHz
5.5 µV + 0.64 µV/mV
5 µV + 0.12 µV/mV
5 µV + 0.16 µV/mV
5.6 µV + 0.8 µV/mV
12 µV + 2.8 µV/mV
47 µV + 6.4 µV/mV
47 µV + 6.4 µV/mV
14 µV + 0.24 µV/mV
24 µV + 87 nV/mV
11 µV + 0.13 µV/mV
35 µV + 0.28 µV/mV
47 µV + 0.64 µV/mV
0.11 mV + 1.6 µV/mV
0.11 mV + 1.6 µV/mV
0.12 mV + 0.24 mV/V
88 µV + 0.12 mV/V
99 µV + 0.15 mV/V
0.12 mV + 0.24 mV/V
0.29 mV + 0.56 mV/V
1.1 mV + 1.9 mV/V
1.1 mV + 1.9 mV/V
1.3 mV + 0.24 mV/V
0.94 mV + 0.12 mV/V
1.6 mV + 0.18 mV/V
1.4 mV + 0.28 mV/V
3.7 mV + 0.72 mV/V
6.8 mV + 0.15 mV/V
10 mV + 0.16 mV/V
12 mV + 0.2 mV/V
13 mV + 0.24 mV/V
93 mV + 1.6 mV/V
88 mV + 0.24 mV/V
Fluke 5522A
AC Voltage – Measure3
(1 to 10) mV
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
6.1 µV + 0.0003 mV/mV
4.1 µV + 0.0002 mV/mV
4.2 µV + 0.0003 mV/mV
4.9 µV + 0.001 mV/mV
9 µV + 0.005 mV/mV
45 µV + 0.04 mV/mV
HP 3458A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 7 of 14
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Voltage – Measure3
(cont)
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) kV
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
60 Hz
12 µV + 0.000 07 mV/mV
2.7 µV + 0.000 07 mV/mV
11 µV + 0.000 14 mV/mV
12 µV + 0.0003 mV/mV
17 µV + 0.0008 mV/mV
47 µV + 0.003 mV/mV
0.12 mV + 0.01 mV/mV
3.8 mV + 0.02 mV/mV
0.12 mV + 0.000 07 V/V
0.1 mV + 0.000 07 V/V
0.11 mV + 0.000 14 V/V
0.12 mV + 0.0003 V/V
0.17 mV + 0.0008 V/V
0.47 mV + 0.003 V/V
1.2 mV + 0.01 V/V
38 mV + 0.015 V/V
1.2 mV + 0.000 07 V/V
1 mV + 0.000 07 V/V
1 mV + 0.000 14 V/V
1.2 mV + 0.0003 V/V
1.7 mV + 0.0008 V/V
4.7 mV + 0.003 V/V
12 mV + 0.01 V/V
0.38 V + 0.015 V/V
13 mV + 0.0002 V/V
11 mV + 0.0002 V/V
11 mV + 0.0002 V/V
13 mV + 0.0004 V/V
21 mV + 0.001 V/V
57 mV + 0.004 V/V
0.17 V + 0.015 V/V
99 mV + 0.0004 V/V
85 mV + 0.0004 V/V
98 mV + 0.0006 V/V
0.14 V + 0.0012 V/V
0.27 V + 0.003 V/V
5.8 %
HP 3458A
Fluke 80K-40
probe & HP
3458A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 8 of 14
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(29 to 330) µA
330 μA to 3.3 mA
(3.3 to 33) mA
(33 mA to 330) mA
330 mA to 1.1 A
(1.1 to 3) A
(3 to 11) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.13 µA + 1.6 nA/µA
0.12 µA + 1.2 nA/µA
0.11 µA + 1 nA/µA
0.19 µA + 2.4 nA/µA
0.35 µA + 6.4 nA/µA
0.70 µA + 13 nA/µA
0.65 µA + 1.6 µA/mA
0.45 µA + 1 µA/mA
0.39 µA + 0.8 µA/mA
0.69 µA + 1.6 µA/mA
2.9 µA + 1.6 µA/mA
3.4 µA + 8 µA/mA
6.4 µA + 1.4 µA/mA
4 µA + 0.72 µA/mA
2.7 µA + 0.32 µA/mA
3.7 µA + 0.64 µA/mA
7.7 µA + 1.6 µA/mA
14 µA + 3.2 µA/mA
65 µA + 1.4 µA/mA
42 µA + 0.72 µA/mA
29 µA + 0.31 µA/mA
68 µA + 0.8 µA/mA
0.13 mA + 1.6 µA/mA
0.27 mA + 3.2 µA/mA
0.56 mA + 1.4 mA/A
0.22 mA + 0.4 mA/A
2.4 mA + 4.8 mA/A
11 mA + 20 mA/A
1.7 mA + 1.4 mA/A
0.61 mA + 0.48 mA/A
6.1 mA + 4.8 mA/A
26 mA + 20 mA/A
3.1 mA + 0.48 mA/A
4 mA + 0.8 mA/A
74 mA + 24 mA/A
Fluke 5522A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 9 of 14
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate3
(cont)
(11 to 20.5) A
Clamp-On Ammeters
(3.2 to 200) A
(16 to 1000) A
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
45 Hz to 1 kHz
15 mA + 0.96 mA/A
17 mA + 1.2 mA/A
0.27 A + 24 mA/A
7.6 mA + 3.1 mA/A
38 mA + 3.1 mA/A
Fluke 5522A
5520A w/:
10-turn coil
50-turn coil
AC Current – Measure3
Up to 100 μA
100 μA to 1 mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
57 nA + 4 nA/µA
45 nA + 1.5 nA/µA
40 nA + 0.64 nA/µA
0.43 µA + 0.0041 mA/mA
0.31 µA + 0.0016 mA/mA
0.26 µA + 0.000 67 mA/mA
0.25 µA + 0.000 37 mA/mA
0.26 µA + 0.000 67 mA/mA
0.63 µA + 0.0042 mA/mA
1.8 µA + 0.0056 mA/mA
2.4 µA + 0.0041 mA/mA
2.3 µA + 0.0016 mA/mA
2.3 µA + 0.000 67 mA/mA
2.3 µA + 0.000 37 mA/mA
2.3 µA + 0.000 67 mA/mA
4.5 µA + 0.0041 mA/mA
16 µA + 0.0056 mA/mA
2.4 µA + 0.0041 mA/mA
2.3 µA + 0.0016 mA/mA
2.3 µA + 0.000 67 mA/mA
2.3 µA + 0.000 37 mA/mA
2.3 µA + 0.000 67 mA/mA
4.5 µA + 0.0041 mA/mA
16 µA + 0.0056 mA/mA
0.42 mA + 0.0041 A/A
0.3 mA + 0.0017 A/A
0.26 mA + 0.0009 A/A
0.27 mA + 0.0011 A/A
0.37 mA + 0.0031 A/A
0.92 mA + 0.01 A/A
HP 3458A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 10 of 14
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Oscilloscopes3 –
DC
50 Ω
1 MΩ
Square Wave
50 Ω
1 MΩ
Edge Into 50 Ω
Leveled Sine Wave
Time Marker
Wave Generator
± (0 to 6.6) V
± (0 to 130) V
1 mV to 6 V
p-p
1 mV to 130 Vp-p
10 Hz to 1 kHz
(1 to 100) kHz
(200 to 300) ps
(100 kHz to 2 MHz)
(200 to 350) ps
(2 to 10) MHz
5 mV to 5.5 V
50 kHz (reference)
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
4 mV to 3.5 V
(600 to 1100) MHz
5 s to 50 ms
50 ms to 1 ns
1.8 mV to 2.8 V
p-p
(50 Ω)
10 Hz to 100 kHz
1.8 mV to 55 V
p-p
(1 MΩ)
10 Hz to 100 kHz
33 µV + 2 mV/V
33 µV + 0.39 mV/V
91 µV + 4.3 mV/V
0.2 mV + 0.8 mV/V
0.24 mV + 2 mV/V
82 ps
82 ps
0.33 mV + 17 mV/V
0.4 mV + 31 mV/V
0.43 mV + 36 mV/V
0.53 mV + 57 mV/V
0.58 mV + 67 mV/V
0.0021 % + (t / 1000) %
0.000 36 %
0.12 mV + 23 mV/V
0.12 mV + 23 mV/V
Fluke
5522A/SC1100
Fluke 5522A
t = time in
seconds | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 11 of 14
III. Fluid Quantities
Parameter/Equipment
Range CMC2, 5 (±) Comments
Gas Flow – Air & N2
Laminar Flow
Sonic Flow
Volumetric – Pipettes
(0.01 to 50) SLPM
(10 to 120) SLPM
Up to 31 mL
(31 to 50) mL
0.41 %
0.41 %
0.023 µL
0.1 µL
Fluke Molbox standard
Electronic balance, reference
mass
IV. Mechanical
Parameter/Equipment
Range CMC2, 5, 6 (±) Comments
Pressure3 – Measure &
Measuring Equipment
Hydraulic
Pneumatic
(400 to 10 000) psig
(4 to 200) ins
H2O @ 60 °F
(8 to 17) psia
(-15 to 15) psig
(-15 to 50) psig
(> 50 to 150) psig
(-15 to 100) psig
(> 100 to 300) psig
(-15 to 330) psig
(> 330 to 1000) psig
0.17 psi + 0.000 17
psi/psi
0.008 in·H2O + 0.000
27 in·H2O/in·H2O
0.01 %
0.003 psig
0.0044 psig
0.008 %
0.0083 psi
0.008 %
0.027 psi
0.008 %
Pressurements
W2200/3HP
Ametek PK II
Mensor CPC6050 with sensor
range (8 to 17) psia
Mensor CPC6050 with sensor
range (-15 to 15) psig
Mensor CPC6050 with sensor
range (-15 to 150) psig
Mensor CPC6050 with sensor
range (-15 to 300) psig
Mensor CPC6050 with sensor
range (-15 to 1000) psig | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 12 of 14
Parameter/Equipment
Range CMC2, 5, 6 (±) Comments
Torque – Measure3
(2 to 20) ozf·in
(2.5 to 25) lbf·in
(25 to 75) lbf·in
(10 to 100) lbf·ft
(25 to 250) lbf·ft
(100 to 1000) lbf·ft
0.32 %
0.59 %
1.2 %
0.59 %
0.32 %
0.59 %
Mountz BMX20z
Mountz BMX25i
Jetco TED-75is-P
Mountz LTT-100F
Mountz BMX250F
Mountz BMX 1000F
Torque Transducers3
10 lbf·in to 250 lbf·ft
0.036 %
Torque arms, Class 6
weights
Scales3
Up to 4000 lb
0.82 x R
Class 6 weights
R = Unit Under Test
resolution
V. Thermodynamic
Parameter/Equipment
Range CMC2, 6 (±) Comments
Temperature – Measure &
Measuring Equipment3
(-197 to 420) °C
(420 to 1000) °C
0.026 °C +
0.000 018 x TChange from -197
0.012 °C +
0.000 092 x TChange from 420
2560 thermometer w/
5614 PRT
5624 PRT
Temperature – Measure3
(-70 to 180) °C
(10 to 60) °C
0.23 °C
0.12 °C
Vaisala M170 with
HMP77B
Thunder Scientific
1200
Dewpoint – Measuring
Equipment
(-80 to < -50) °C
(-50 to < 0) °C
(0 to 20) °C
(-20 to 20) °C
1.1 °C
0.18 °C
0.13 °C
0.14 °C
Mitchell S8000RS
chilled mirror
hygrometer
Thunder Scientific
1200 | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 13 of 14
Parameter/Equipment
Range CMC2, 6 (±) Comments
Relative Humidity –
Measuring Equipment
(10 to 95) % RH
0.67 % RH
Thunder Scientific
1200
Relative Humidity –
Measure3
Up to 100 % RH
1.3 % RH
Vaisala M170 with
HMP77B
VI. Time & Frequency
Parameter/Equipment
Range CMC2, 6 (±) Comments
Frequency – Measuring
Equipment3
1 µHz to 21 MHz 0.58 µHz + 8.2 µHz/Hz
HP 3325B
Frequency – Measure3
1 mHz to 225 MHz
5.8 µHz + 4.1 µHz/Hz
Agilent 53132A
____________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The measurands stated are generated using the indica ted instrument (see Comments). This capability is
suitable for the calibration of the devices intended to measure the measuran d in the ranges
indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the
reading plus a fixed floor specification.
5 In the statement of CMC, the value is defined as the percentage of reading ; L is the numerical value of
the nominal length of the device measured in inches, unless otherwise noted. | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1486.02) 04/26/2024 Page 14 of 14
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 15 | ISO/IEC 17025:20 17; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- ACR Technical ServicesNewport News, VA · ~54 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - HamptonHampton, VA · ~77 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hoffer Calibration Services, LLC (a Subsidiary of Hoffer Flow Controls, Inc.)Elizabeth City, NC · ~147 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Norfolk, NCELIZABETH CITY, NC · ~147 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SP HB Instrument Calibration LaboratoryPocomoke City, MD · ~148 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.