FindTestingLabs
Registers refreshed 2026-10-25.See refresh dates
United States

Trescal, Inc. - Norfolk, NC

ELIZABETH CITY, NC, United States

Visit website
A2LA 2737.02ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
41
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 41 scope lines.

A2LA certificate 2737.02 · 41 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006--
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 2 of 40 Parameter/Equipment Range CMC2 (±) Comments Cylindrical Diameters – External Up to 12.1 in 120 µin + 3.5 µin/in GageMaker MicTrac w/ gage blocks Tape Measure & Steel Ruler3 (No Tension) Up to 36 in (3 to 300) ft 0.0023 in 0.0046 in + 6.1 µin/in Gage blocks Stanley 34-762 tape measure II. Dimensional Testing/Calibration Parameter/Equipment Range CMC2 (±) Comments 1D – Length Up to 12.1 in 120 µin + 3.5 µin/in GageMaker MicTrac w/ gage blocks III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage3 – Generate (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V (0 to 120) mV (0 to 1.2) V (0 to 12) V (0 to 120) V (0 to 1020) V 6 nV/mV + 0.5 µV 3.5 µV/V + 0.7 µV 2.5 µV/V + 2.9 µV 2.4 µV/V + 6.7 µV 3.4 µV/V + 70 µV 4.2 µV/V + 0.83 mV 0.8 µV + 9.3 µV/V 1.9 µV + 5.8 µV/V 10 µV + 6.2 µV/V 0.1 mV + 8.5 µV/V 1 mV + 8.5 µV/V Fluke 5720A Fluke 5560A DC Voltage3 – Measure (0 to 200) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V 0.24 µV + 5.0 µV/V 1.1 µV + 3.7 µV/V 10 µV + 3.0 µV/V 0.88 mV + 3.2 µV/V 1.4 mV + 5.0 µV/V Fluke 8508A
3-DC High Voltage; DC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 3 of 40 Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC High Voltage3 – Generate & Measure Measure (1 to 10) kV (10 to 70) kV 0.38 V + 0.36 mV/V 4.9 V + 0.49 mV/V Vitrek 4700 w/ HVL-70 DC Current3 – Generate Clamps / Loops (0 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (1.1 to 2.999 99) A (1.1 to 10.9999) A (11 to 20.5) A (0 to 120) µA (0 to 1.2) mA (0 to 12) mA (0 to 120) mA (0 to 1.2) A (0 to 3.1) A (0 to 12) A (0 to 30.2) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A 6.1 nA + 35 pA/µA 13 nA + 28 nA/mA 0.18 µA + 25 nA/mA 1.3 µA + 1.0 mA/A 85 µA + 82 µA/A 1.1 mA + 0.30 mA/A 8.2 mA + 0.39 mA/A 17 mA + 0.78 mA/A 6 nA + 97 µA/A 15 nA + 78 µA/A 82 nA + 78 µA/A 0.82 µA + 78 µA/A 10 µA + 0.12 mA/A 0.15 mA + 0.23 mA/A 0.25 mA + 0.23 mA/A 0.5 mA + 0.78 mA/A 50 mA + 6.5 mA/A 0.18 A + 3.4 mA/A 0.83 A + 3.3 mA/A Fluke 5720A Fluke 5522A Fluke 5560A Fluke 5520A w/ 5500A/coil DC Current3 – Measure (0 to 100) nA 100 nA to 1 µA (1 to 10) µA (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (0 to 2) A (2 to 20) A (20 to 100) A (100 to 500) A 46 pA + 30 µA/A 3.0 pA + 24 µA/A 0.44 nA + 19 µA/A 0.26 nA + 16 µA/A 0.15 µA + 1.5 mA/A 92 nA + 16 µA/A 0.92 µA + 32 µA/A 2.4 µA + 0.10 mA/A 26 µA + 0.18 mA/A 0.56 mA + 0.54 mA/A 0.046 % 0.66 % Agilent 3458A Fluke 8508A 3458A & current shunts
-
4-DC Resistance
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 4 of 40 Parameter/Equipment Range CMC2, 4 (±) Comments DC Resistance3 – Generate 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω 330 Ω to 1.099 99 kΩ (1.1 to 3.299 999) kΩ (3.3 to 10.999 99) kΩ (11 to 32.999 99) kΩ (33 to 109.9999) kΩ (110 to 329.9999) kΩ 330 kΩ to 1.099 999 MΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ (0 to 12) Ω (12 to 120) Ω 120 Ω to 1.2 kΩ (1.2 to 12) kΩ (12 to 120) kΩ 120 kΩ to 1.2 MΩ (1.2 to 12) MΩ (12 to 120) MΩ (120 to 1200) MΩ 50 µΩ 96 µΩ 0.18 mΩ 0.28 mΩ 0.52 mΩ 1.3 mΩ 2.4 mΩ 9.0 mΩ 17 mΩ 90 mΩ 0.17 Ω 1.1 Ω 2.2 Ω 20 Ω 40 Ω 0.43 kΩ 0.98 kΩ 50 kΩ 1.1 mΩ + 24 µΩ/Ω 1.5 mΩ + 24 µΩ/Ω 1.9 mΩ + 23 µΩ/Ω 4.1 mΩ + 22 µΩ/Ω 9.2 mΩ + 22 µΩ/Ω 42 mΩ + 22 µΩ/Ω 93 mΩ + 22 µΩ/Ω 0.41 Ω + 22 µΩ/Ω 0.91 Ω + 23 µΩ/Ω 8.6 Ω + 26 µΩ/Ω 14 Ω + 25 µΩ/Ω 90 Ω + 47 µΩ/Ω 0.39 kΩ + 0.10 mΩ/Ω 4.2 kΩ + 0.19 mΩ/Ω 15 kΩ + 0.39 mΩ/Ω 0.34 MΩ + 2.3 mΩ/Ω 4.2 MΩ + 12 mΩ/Ω 1 mΩ + 19 µΩ/Ω 1.2 mΩ + 19 µΩ/Ω 4.4 mΩ + 19 µΩ/Ω 44 mΩ + 19 µΩ/Ω 0.44 Ω + 19 µΩ/Ω 4.4 Ω + 19 µΩ/Ω 63 Ω + 27 µΩ/Ω 6.5 kΩ + 0.33 mΩ/Ω 0.47 MΩ + 3.1 mΩ/Ω Fluke 5720A Fluke 5522A Fluke 5560A
See scope document
5-DC Resistance; Electrical Calibration of Thermocouples & Indicators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 5 of 40 Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Resistance3 – Generate, Fixed Points, High Voltage Up to 20 V Up to 100 V Up to 1000 V Up to 5000 V 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 TΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 TΩ 0.0013 % 0.0013 % 0.0013 % 0.0022 % 0.004 % 0.012 % 0.062 % 0.24 % 0.36 % 0.51 % 1.5 % 0.54 % 0.5 % 0.5 % 0.5 % 0.51 % 0.51 % 2.8 % IET VRS-100-11- 1K-BP-10KV DC Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 77 µΩ + 15 µΩ/Ω 0.74 mΩ + 11 µΩ/Ω 2.0 mΩ + 8.0 µΩ/Ω 20 mΩ + 8.0 µΩ/Ω 0.20 Ω + 8.0 µΩ/Ω 4.4 Ω + 14 µΩ/Ω 0.18 kΩ + 54 µΩ/Ω 4.2 kΩ + 0.52 mΩ/Ω 0.31 MΩ + 5.1 mΩ/Ω HP 3458A DC Resistance3 – Measure 10 mΩ 100 mΩ 0.0014 % 0.0028 % Current shunts & 8508A Electrical Calibration of Thermocouples & Indicators3 – Type B (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C 0.34 ᵒC 0.26 ᵒC 0.23 ᵒC 0.26 ᵒC Fluke 5522A
-
6-thermocouples; indicators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 6 of 40 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouples & Indicators3 – (cont) Type C Type E Type J Type K Type L Type N Type R Type S Type T (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to - 30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) ᵒC (-100 to 800) ᵒC (800 - 900) ᵒC (-200 to -100) °C (-100 to - 25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.23 ᵒC 0.2 ᵒC 0.24 ᵒC 0.39 ᵒC 0.65 ᵒC 0.39 ᵒC 0.13 ᵒC 0.12 ᵒC 0.13 ᵒC 0.17 ᵒC 0.21 ᵒC 0.13 ᵒC 0.12 ᵒC 0.14 ᵒC 0.18 ᵒC 0.26 ᵒC 0.15 ᵒC 0.13 ᵒC 0.21 ᵒC 0.31 ᵒC 0.29 ᵒC 0.20 ᵒC 0.13 ᵒC 0.31 ᵒC 0.18 ᵒC 0.15 ᵒC 0.15 ᵒC 0.21 ᵒC 0.44 ᵒC 0.28 ᵒC 0.26 ᵒC 0.31 ᵒC 0.37 ᵒC 0.28 ᵒC 0.29 ᵒC 0.36 ᵒC 0.49 ᵒC 0.21 ᵒC 0.15 ᵒC 0.14 ᵒC Fluke 5522A
See scope document
7-Thermocouples & Indicators; RTD Indicators
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 7 of 40 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouples & Indicators3 – (cont) Type U (-200 to 0) °C (0 to 600) °C 0.47 ᵒC 0.21 ᵒC Fluke 5522A Electrical Calibration of RTD Indicators3 – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.057 ᵒC 0.056 ᵒC 0.068 ᵒC 0.081 ᵒC 0.088 ᵒC 0.10 ᵒC 0.19 ᵒC 0.056 ᵒC 0.056 ᵒC 0.068 ᵒC 0.081 ᵒC 0.088 ᵒC 0.10 ᵒC 0.20 ᵒC 0.051 ᵒC 0.056 ᵒC 0.062 ᵒC 0.068 ᵒC 0.074 ᵒC 0.081 ᵒC 0.041 ᵒC 0.18 ᵒC 0.051 ᵒC 0.051 ᵒC 0.051 ᵒC 0.057 ᵒC 0.10 ᵒC 0.11 ᵒC 0.12 ᵒC 0.13 ᵒC Fluke 5522A
See scope document
8-RTD Indicators; Oscilloscope; Power meter w/ power sensors
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 8 of 40 Parameter/Equipment Range CMC2, 5 (±) Comments Electrical Calibration of RTD Indicators3 – (cont) Pt 385, 500 Ω Pt 385, 1000 Ω PtNi 385, 120 Ω Cu 427.10 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-100 to 260) °C 0.051 ᵒC 0.056 ᵒC 0.056 ᵒC 0.062 ᵒC 0.074 ᵒC 0.074 ᵒC 0.081 ᵒC 0.095 ᵒC 0.047 ᵒC 0.047 ᵒC 0.051 ᵒC 0.057 ᵒC 0.062 ᵒC 0.068 ᵒC 0.068 ᵒC 0.18 ᵒC 0.062 ᵒC 0.062 ᵒC 0.11 ᵒC 0.23 ᵒC Fluke 5522A Oscilloscope3– DC into 50 Ω Load DC into 1 MΩ Load Rise Time Bandwidth (-6.6 to 6.6) V (-130 to 130) V ≤ 300 ps (Up to 2 MHz) ≤ 350 ps (Above 2 MHz) 50 kHz (reference) 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz (1.1 to 16) GHz (16 to 18) GHz (18 to 26.5) GHz (26.5 to 33) GHz (33 to 35) GHz (35 to 40) GHz (40 to 47) GHz (47 to 50) GHz 33 µV + 2 mV/V 33 µV + 0.39 mV/V 82 ps 82 ps 0.33 mV + 17 mV/V 0.4 mV + 31 mV/V 0.43 mV + 36 mV/V 0.53 mV + 57 mV/V 0.58 mV + 67 mV/V 3.1 % 3.3 % 4.1 % 4.3 % 4.5 % 4.7 % 5.1 % 5.6 % Fluke 5520A- SC1100 Power meter w/ power sensors
-
9-50 Ω Load
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 9 of 40 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Oscilloscope3– (cont) Time Markers: Source & Period into a 50 Ω Load Amplitude: 1 MΩ, 10 Hz to 1 kHz 1 MΩ, (1 to 10) kHz 50 Ω 5 s to 50 ms 50 ms to 1 ns 1 mV to 130 V(pk-pk) 1 mV to 130 V(pk-pk) 1.0 mV to 6.6 V(pk-pk) 0.000 63 % + t x 0.1 % 0.000 52 % 0.2 mV + 0.8 mV/V 0.24 mV + 2 mV/V 91 µV mV + 4.3 mV/V Fluke 5520A- SC1100 t = time in seconds DC Power3 – Generate Up to 330 µA Up to 3.3 mA Up to 33 mA Up to 330 mA Up to 1.1 A Up to 3 A Up to 11 A Up to 20.5 A Up to 120 µA Up to 1.2 mA Up to 12 mA Up to 120 mA Up to 1.2 A Up to 3.1 A Up to 12 A Up to 30.2 A Up to 1020 V Up to 337 mW (0.337 to 3.366) W (3.366 to 33.66) W (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.91) kW Up to 1020 V Up to 122 mW (0.12 to 1.224) W (1.225 to 12.24) W (12.24 to 122.4) W (0.1224 to 1.224) kW (1.224 to 3.162) kW (3.162 to 12.24) kW (12.24 to 30.8) kW 0.017 % 0.021 % 0.0093 % 0.0093 % 0.019 % 0.043 % 0.044 % 0.13 % 0.015 % 0.0092 % 0.0087 % 0.0087 % 0.013 % 0.028 % 0.025 % 0.08 % Fluke 5522A Fluke 5560A
See scope document
10-AC Power
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 10 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power3 – Generate See Table below See Table below Fluke 5522A (45 to 65) Hz (3.366 to 33.66) W (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0 ° PF=1.000 0.052 % 0.068 % 0.076 % 0.083 % 0.17 % Ø 10 ° PF=0.985 0.06 % 0.075 % 0.082 % 0.088 % 0.18 % Ø 20 ° PF=0.940 0.082 % 0.093 % 0.099 % 0.1 % 0.18 % Ø 30 ° PF=0.866 0.11 % 0.12 % 0.13 % 0.2 % Ø 40 ° PF=0.766 0.16 % 0.17 % 0.23 % Ø 50 ° PF=0.643 0.21 % 0.22 % 0.27 % Ø 60 ° PF=0.500 0.31 % 0.35 % Ø 70 ° PF=0.342 0.48 % 0.49 % 0.51 % Ø 80 ° PF=0.174 0.99 % 1 % (65 to 500) Hz (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0 ° PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 % Ø 10 ° PF=0.985 0.094 % 0.1 % 0.11 % 0.14 % 0.22 % Ø 20 ° PF=0.940 0.17 % 0.18 % 0.2 % 0.26 % Ø 30 ° PF=0.866 0.26 % 0.28 % 0.33 % Ø 40 ° PF=0.766 0.37 % 0.39 % 0.42 % Ø 50 ° PF=0.643 0.53 % 0.56 % Ø 60 ° PF=0.500 0.76 % 0.77 % 0.78 % Ø 70 ° PF=0.342 1.2 % Ø 80 ° PF=0.174 2.5 %
-
11-AC Power
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 11 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power – Generate3 (cont) See Table below See Table below Fluke 5560A 500 Hz to 1 kHz (33.66 to 336.6) W (0.3366 to 1.122) kW (1.122 to 3.06) kW (3.06 to 11.22) kW (11.22 to 20.9) kW Ø 0 ° PF=1.000 0.052 % 0.068 % 0.076 % 0.12 % 0.21 % (45 to 65) Hz (1.22 to 12.2) W (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 0 ° PF=1.000 0.038 % 0.029 % 0.034 % 0.048 % 0.04 % 0.11 % Ø 10 ° PF=0.985 0.049 % 0.042 % 0.046 % 0.057 % 0.051 % 0.11 % Ø 20 ° PF=0.940 0.074 % 0.07 % 0.072 % 0.079 % 0.075 % 0.12 % Ø 30 ° PF=0.866 0.11 % 0.15 % Ø 40 ° PF=0.766 0.15 % Ø 50 ° PF=0.643 0.21 % Ø 60 ° PF=0.500 0.3 % Ø 70 ° PF=0.342 0.48 % Ø 80 ° PF=0.174 0.99 % (65 to 500) Hz (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 0 ° PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 % Ø 10 ° PF=0.985 0.068 % 0.071 % 0.078 % 0.074 % 0.12 % Ø 20 ° PF=0.940 0.14 % 0.17 % Ø 30 ° PF=0.866 0.2 % 0.21 % 0.23 % Ø 40 ° PF=0.766 0.29 % 0.3 % 0.31 % Ø 50 ° PF=0.643 0.42 % (65 to 500) Hz (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 60 ° PF=0.500 0.61 %
-
12-AC Power
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 12 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power – Generate3 (cont) See Table below See Table below Fluke 5560A (65 to 500) Hz (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 70 ° PF=0.342 0.96 % Ø 80 ° PF=0.174 2 % 500 Hz to 1 kHz (12.2 to 122) W (0.122 to 1.22) kW (1.22 to 3.16) kW (3.16 to 12.2) kW (12.2 to 30.8) kW Ø 0 ° PF=1.000 0.029 % 0.034 % 0.048 % 0.04 % 0.11 % Ø 10 ° PF=0.985 0.13 % 0.16 % Ø 20 ° PF=0.940 0.26% 0.28 % Ø 30 ° PF=0.866 0.41% 0.42 % Ø 40 ° PF=0.766 0.59 % 0.6 % Ø 50 ° PF=0.643 0.83 % Ø 60 ° PF=0.500 1.2 % Ø 70 ° PF=0.342 1.9 % Ø 80 ° PF=0.174 4 % (1 to 5) kHz (6 to 60) W (60 to 600) W (0.6 to 1.55) kW Ø 0 ° PF=1.000 0.071 % 0.082 % Ø 10 ° PF=0.985 0.64 % Ø 20 ° PF=0.940 1.3 % Ø 30 ° PF=0.866 2 % Ø 40 ° PF=0.766 2.8 % Ø 50 ° PF=0.643 4 % (5 to 10) kHz (3 to 30) W (30 to 300) W Ø 0 ° PF=1.000 0.28 % 0.34 %
See scope document
13-AC Power; Duty Cycle; AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 13 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Power – Generate3 (cont) See Table below See Table below Fluke 5560A (5 to 10) kHz (3 to 30) W (30 to 300) W Ø 10 ° PF=0.985 1.4 % Ø 20 ° PF=0.940 2.7 % Ø 30 ° PF=0.866 4.2 % (10 to 30) kHz (3 to 300) W Ø 0 ° PF=1.000 1.1 % Ø 10 ° PF=0.985 3.4 % Ø 20 ° PF=0.940 5.9% Parameter/Equipment Range CMC2, 4, 5 (±) Comments Duty Cycle3 – Generate (1 to 9.99) % (10 to 49.99) % 50 % (50.01 to 90) % (90.01 to 99) 0.32 % 0.02 % 0.013 % 0.02 % 0.31 % Fluke 5522A Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3 – Generate Up to 2.2 mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 4.7 µV + 0.19 µV/mV 4.4 µV + 79 nV/mV 4.3 µV + 71 nV/mV 4.7 µV + 0.16 µV/mV 6 µV + 0.41 µV/mV 11 µV + 0.82 µV/mV 22 µV + 1.1 µV/mV 23 µV + 2.3 µV/mV Fluke 5720A
-
14-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 14 of 40 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3 – Generate (cont) (2.2 to 22) mV (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (22 to 220) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz* (300 to 500) kHz* (0.5 to 1) MHz* 6.3 µV + 0.41 µV/mV 4.9 µV + 79 nV/mV 4.9 µV + 69 nV/mV 6 µV + 0.16 µV/mV 8.9 µV + 0.4 µV/mV 17 µV + 0.79 µV/mV 29 µV + 1.1 µV/mV 36 µV + 2.2 µV/mV 23 µV + 0.21 µV/mV 12 µV + 80 nV/mV 12 µV + 70 nV/mV 19 µV + 0.17 µV/mV 27 µV + 0.44 µV/mV 62 µV + 0.87 µV/mV 88 µV + 1.1 µV/mV 0.18 mV + 2.2 µV/mV 0.23 mV + 0.21 mV/V 81 µV + 77 µV/V 44 µV + 33 µV/V 88 µV + 58 µV/V 0.14 mV + 86 µV/V 0.43 mV + 0.31 mV/V 0.84 mV + 0.82 mV/V 1.7 mV + 1.2 mV/V 2.3 mV + 0.21 mV/V 0.81 mV + 76 µV/V 0.20 mV + 40 µV/V 0.65 mV + 64 µV/V 1 mV + 84 µV/V 3.3 mV + 0.25 mV/V 6.7 mV + 0.88 mV/V 10 mV + 1.2 mV/V 23 mV + 0.21 mV/V 8.5 mV + 75 µV/V 5.4 mV + 36 µV/V 7.3 mV + 67 µV/V 14 mV + 0.11 mV/V 54 mV + 0.79 mV/V 0.14 V + 4.2 mV/V 0.24 V + 7 mV/V Fluke 5720A * Limited to 2.2E7 V-Hz
See scope document
15-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 15 of 40 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3 – Generate (cont) (220 to 1100) V (33 to 330) V (330 to 1020) V (15 to 50) Hz** 50 Hz to 1 kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 9.1 mV + 0.25 mV/V 78 mV + 57 µV/V 14 mV + 0.15 mV/V 18 mV + 0.16 mV/V 19 mV + 0.20 mV/V 20 mV + 0.25 mV/V 98 mV + 1.6 mV/V 0.11 V + 0.24 mV/V 96 mV + 0.20 mV/V 0.11 V + 0.23 mV/V Fluke 5720A **250V Max Fluke 5522A AC Voltage – Generate3 (1 to 12) mV (12 to 120) mV (0.12 to 1.2) V (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40.01 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 0.11 mV + 50 mV/V 8.9 µV + 1.9 mV/V 7.7 µV + 0.68 mV/V 6.1 µV + 0.12 mV/V 6.3 µV + 0.29 mV/V 16 µV + 1.2 mV/V 36 µV + 6.2 mV/V 36 µV + 6.2 mV/V 1.2 mV + 50 mV/V 30 µV + 1.9 mV/V 15 µV + 0.68 mV/V 7.4 µV + 0.11 mV/V 11 µV + 0.27 mV/V 28 µV + 0.62 mV/V 49 µV + 1.6 mV/V 49 µV + 1.6 mV/V 12 mV + 50 mV/V 0.3 mV + 1.9 mV/V 0.15 mV + 0.68 mV/V 74 µV + 0.11 mV/V 21 µV + 0.11 mV/V 42 µV + 0.23 mV/V 0.11 mV + 0.54 mV/V 0.26 mV + 1.5 mV/V 0.26 mV + 1.5 mV/V Fluke 5560A
See scope document
16-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 16 of 40 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (cont) (1.2 to 12) V (12 to 120) V (120 to 330) V (330 to 1020) V (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40.01 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.01 to 3) Hz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40.01 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz * (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 10 kHz 0.12 V + 50 mV/V 3 mV + 1.9 mV/V 1.6 mV + 0.68 mV/V 0.49 mV + 0.11 mV/V 0.18 mV + 0.11 mV/V 0.33 mV + 0.23 mV/V 0.77 mV + 0.54 mV/V 2.5 mV + 1.6 mV/V 2.5 mV + 1.6 mV/V 1.2 V + 50 mV/V 30 mV + 1.9 mV/V 16 mV + 0.68 mV/V 4.8 mV + 0.11 mV/V 1.8 mV + 0.11 mV/V 3.3 mV + 0.23 mV/V 7.7 mV + 0.54 mV/V 39 mV + 1.6 mV/V 0.3 V + 1.9 mV/V 0.16 V + 0.68 mV/V 21 mV + 0.11 mV/V 36 mV + 0.23 mV/V 0.16 V + 1.2 mV/V 0.7 V + 1.9 mV/V 0.3 V + 0.68 mV/V 0.12 V + 0.11 mV/V Fluke 5560A * Max output 70 V AC Voltage3 – Measure (0 to 10) mV (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 4) MHz (4 to 8) MHz 6.1 µV + 0.30 mV/V 4.1 µV + 0.20 mV/V 4.2 µV + 0.30 mV/V 4.9 µV + 1.0 mV/V 9.0 µV + 5.0 mV/V 45 µV + 40 mV/V 20 µV + 12 mV/V 0.44 mV + 70 mV/V 1.1 mV + 0.20 V/V Agilent 3458A-002
See scope document
17-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 17 of 40 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage3 – Measure (cont) (10 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V (10 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 12 µV + 70 µV/V 10 µV + 70 µV/V 11 µV + 0.14 mV/V 12 µV + 0.30 mV/V 17 µV + 0.80 mV/V 47 µV + 3.0 mV/V 0.12 mV + 10 mV/V 3.8 mV + 15 mV/V 4.1 mV + 40 mV/V 8.9 mV + 40 mV/V 14 mV + 0.15 V/V 0.12 mV + 70 µV/V 0.10 mV + 70 µV/V 0.11 mV + 0.14 mV/V 0.12 mV + 0.30 mV/V 0.17 mV + 0.80 mV/V 0.47 mV + 3.0 mV/V 1.1 mV + 10 mV/V 38 mV + 15 mV/V 41 mV + 40 mV/V 89 mV + 40 mV/V 0.14 V + 0.15 V/V 1.2 mV + 70 µV/V 1.0 mV + 70 µV/V 1.1 mV + 0.14 mV/V 1.2 mV + 0.30 mV/V 1.7 mV + 0.80 mV/V 4.7 mV + 3.0 mV/V 12 mV + 10 mV/V 0.38 V + 15 mV/V 0.41 V + 40 mV/V 0.89 V + 40 mV/V 1.4 V + 0.15 V/V 13 mV + 0.20 mV/V 11 mV + 0.20 mV/V 11 mV + 0.20 mV/V 13 mV + 0.35 mV/V 21 mV + 1.2 mV/V 57 mV + 4.0 mV/V 0.17 V + 15 mV/V 99 mV + 0.40 mV/V 85 mV + 0.40 mV/V 99 mV + 0.60 mV/V 0.14 V + 1.2 mV/V 0.27 V + 3.0 mV/V Agilent 3458A-002
-
18-AC High Voltage; Inductance; Capacitance
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 18 of 40 Parameter/Range Frequency CMC2, 4 (±) Comments AC High Voltage3 – Generate & Measure: (1 to 10) kV Measure: (10 to 70) kV (50 to 400) Hz 1.5 V + 1.4 mV/V 12 V + 1.2 mV/V Vitrek 4700 w/ HVL- 70 Inductance3 – Measure 1 µH to 1 mH (1 to 100) mH 100 mH to 5 H (0.1 to 1) kHz 1.4 µH 0.10 mH 5.1 mH GR 1689-M CMC is stated at 1 kHz Inductance3 – Generate 10 mH 100 mH 100 Hz 1 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 49 µH 27 µH 0.14 mH 0.13 mH 0.12 mH 0.12 mH 0.13 mH General Radio 1482 standard inductors Capacitance3 – Generate (1 to 10) pF (10 to 100) pF (100 to 1000) pF (1 to 10) nF (10 to 100) nF (100 to 1000) nF (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.0999) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF 10 Hz to 1 MHz 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (10 to 50) Hz (10 to 20) Hz (0 to 6) Hz (0 to 2) Hz 90 fF 90 fF 91 fF + 64 aF/pF 0.15 pF + 0.11 pF/nF 1.2 pF + 0.12 pF/nF 12 pF + 0.12 pF/nF 8.5 pF + 3.8 mF/F 9.4 pF + 3.9 mF/F 12 pF + 3.9 mF/F 15 pF + 2.0 mF/F 99 pF + 1.9 mF/F 0.14 nF + 1.9 mF/F 0.45 nF + 2.0 mF/F 1.4 nF + 2.1 mF/F 4.5 nF + 2.0 mF/F 14 nF + 2.0 mF/F 58 nF + 3.4 mF/F 0.20 µF + 3.6 mF/F 0.63 µF + 3.5 mF/F 1.9 µF + 3.5 mF/F 6.8 µF + 3.4 mF/F 38 µF + 2.4 mF/F GR 1413 Fluke 5522A
-
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 19 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Capacitance3 – Generate (cont) (11 to 32.9999) mF (33 to 110) mF 200 pF to 1.2 nF (1.2 to 12) nF (> 3 to 12) nF (12 to 120) nF (> 30 to 120) nF (0.12 to 1.2) µF (1.2 to 12) µF (12 to 120) µF (0.12 to 1.2) mF (1.2 to 12) mF (12 to 120) mF (0 to 0.6) Hz (0 to 0.2) Hz 100 Hz to 10 kHz 150 Hz to 5 kHz (10 to 150) Hz 200 Hz to 1.3 kHz (10 to 200) Hz (2 to 310) Hz (0.5 to 110) Hz (0.5 to 40) Hz (0.1 to 11) Hz (0.03 to 4) Hz (0.01 to 1.3) Hz 88 µF + 5.8 mF/F 0.36 mF + 8.6 mF/F 2.4 pF + 0.86 mF/F 6.2 pF + 0.9 mF/F 7.8 pF + 0.9 mF/F 43 pF + 1 mF/F 61 pF + 1 mF/F 0.42 nF + 1 mF/F 4.2 nF + 1 mF/F 40 nF + 1.2 mF/F 0.48 µF + 1.9 mF/F 5.3 µF + 1.9 mF/F 77 µF + 3.9 mF/F Fluke 5560A Inductance – Generate3 (13 to 120) µH (0.120 01 to 1.2) mH (1.2001 to 3.3) mH (3.3 to 12) mH (12 to 83) mH (490 to 550) Hz (550 to 999) Hz 1 kHz (1.001 to 13) kHz (13 to 17) kHz (260 to 330) Hz (330 to 999) Hz 1 kHz (1.001 to 1.6) kHz (1.6 to 2.5) kHz (0.5 to 999) Hz 110 Hz (111 to 800) Hz (800 to 980) Hz (0.5 to 109) Hz 110 Hz (111 to 1000) Hz (1 to 1.4) kHz (0.1 to 99) Hz 100 Hz (101 to 180) Hz (180 to 230) Hz 1.5 % 0.67 % 0.38 % 0.67 % 1.5 % 1.4 % 0.49 % 0.2 % 0.49 % 1.4 % 0.74 % 0.46 % 0.74 % 1.6 % 0.49 % 0.2 % 0.49 % 1.4 % 0.53 % 0.25 % 0.53 % 1.4 % Fluke 5560A
20-Inductance
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 20 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Inductance – Generate3 (cont) (83 to 120) mH (0.120 01 to 0.65) H (0.65 to 1.2) H (1.2001 to 5.5) H (5.5 to 12) H (12.001 to 30) H (30 to 120) H (0.1 to 99) Hz 100 Hz (101 to 320) Hz (320 to 1000) Hz (0.05 to 9.9) Hz 10 Hz (10.1 to 30) Hz (30 to 50) Hz (0.05 to 9.9) Hz 10 Hz (10.1 to 100) Hz (100 to 170) Hz (0.01 to 2.99) Hz 3 Hz (3.01 to 8) Hz (8 to 16) Hz (0.01 to 2.99) Hz 3 Hz (3.01 to 19) Hz (19 to 37) Hz (0.005 to 1.99) Hz 2 Hz (2.01 to 4) Hz (4 to 16) Hz (0.005 to 1.99) Hz 2 Hz (2.01 to 7) Hz (7 to 14) Hz 0.49 % 0.2 % 0.49 % 1.4 % 0.61 % 0.32 % 0.6 % 1.5 % 0.52 % 0.24 % 0.52 % 1.4 % 0.68 % 0.4 % 0.68 % 1.6 % 0.57 % 0.28 % 0.57 % 1.4 % 0.89 % 0.61 % 0.89 % 1.8 % 0.61 % 0.32 % 0.6 % 1.5 % Fluke 5560A
See scope document
21GR 1689-MCapacitance; AC CurrentSee scope document
22-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 22 of 40 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current3 – Generate (cont) (11 to 20.5) A Clamps / Loops3: Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A Non-Toroidal: (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (10 to 16.5) A (16.5 to 150) A (150 to 1025) A (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 18 mA + 1.6 mA/A 20 mA + 1.7 mA/A 0.26 A + 23 mA/A 26 mA + 2.1 mA/A 50 mA + 1.9 mA/A 0.34 A + 1.9 mA/A 60 mA + 6 mA/A 0.11 A + 5.3 mA/A 0.86 A + 5.3 mA/A 60 mA + 3.8 mA/A 0.23 A + 3.7 mA/A 1.2 A + 3.7 mA/A 90 mA + 7.2 mA/A 0.28 A + 6.7 mA/A 1.6 A + 6.7 mA/A Fluke 5522A 5520A w/ 5500A/coil AC Current – Generate3 (12 to 120) µA (0.12 to 1.2) mA (1.2 to 12) mA (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 12 nA + 0.19 mA/A 12 nA + 0.19 mA/A 12 nA + 0.19 mA/A 52 nA + 1.2 mA/A 1 µA + 3.9 mA/A 0.13 µA + 0.19 mA/A 0.13 µA + 0.19 mA/A 0.13 µA + 0.19 mA/A 0.25 µA + 1.2 mA/A 5.5 µA + 3.9 mA/A 1.3 µA + 0.19 mA/A 1.3 µA + 0.19 mA/A 1.3 µA + 0.19 mA/A 2.5 µA + 1.2 mA/A 15 µA + 3.9 mA/A Fluke 5560A
10 to 1025 A
23-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 23 of 40 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (cont) (12 to 120) mA (0.12 to 1.2) A (1.2 to 3.1) A (3.1 to 12) A (12 to 30) A (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (3 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz 13 µA + 0.19 mA/A 6.5 µA + 0.12 mA/A 10 µA + 0.19 mA/A 25 µA + 1.2 mA/A 0.15 mA + 3.9 mA/A 0.13 mA + 0.18 mA/A 75 µA + 0.19 mA/A 0.1 mA + 0.19 mA/A 0.53 mA + 1.9 mA/A 0.77 mA + 3.9 mA/A 0.85 mA + 0.29 mA/A 0.58 mA + 0.23 mA/A 0.65 mA + 0.29 mA/A 2.8 mA + 1.9 mA/A 1.9 mA + 0.29 mA/A 1.2 mA + 0.23 mA/A 1.7 mA + 0.29 mA/A 6.9 mA + 1.9 mA/A 19 mA + 0.78 mA/A 15 mA + 0.54 mA/A 55 mA + 3.9 mA/A Fluke 5560A AC Current3 – Measure (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 57 nA + 4.0 mA/A 0.43 µA + 4.1 mA/A 2.5 µA + 4.1 mA/A 42 µA + 4.0 mA/A 0.42 mA + 4.1 mA/A 45 nA + 1.5 mA/A 3.1 µA + 1.6 mA/A 2.3 µA + 1.6 mA/A 30 µA + 1.5 mA/A 0.30 mA + 1.7 mA/A 41 nA + 0.64 mA/A 0.26 µA + 0.67 mA/A 2.3 µA + 0.67 mA/A 25 µA + 0.60 mA/A 0.26 mA + 0.90 mA/A 3458A
5 to 100 µA
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 24 of 40 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current3 – Measure (cont) (5 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 50 µA to 1 mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 50 µA to 1 mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 50 µA to 1 mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 50 µA to 1 mA (1 to 10) mA (10 to 100) mA (0 to 2) A (0 to 20) A (0 to 2) A (0 to 20) A (0 to 2) A 100 Hz to 1 kHz (1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz 10 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 41 nA + 0.64 mA/A 0.25 µA + 0.37 mA/A 2.3 µA + 0.37 mA/A 24 µA + 0.30 mA/A 0.27 mA + 1.1 mA/A 0.25 µA + 0.37 mA/A 2.3 µA + 0.37 mA/A 24 µA + 0.30 mA/A 0.27 mA + 1.1 mA/A 0.26 µA + 0.67 mA/A 2.3 µA + 0.67 mA/A 25 µA + 0.60 mA/A 0.37 mA + 3.1 mA/A 0.63 µA + 4.1 mA/A 4.5 µA + 4.1 mA/A 62 µA + 4.0 mA/A 0.92 mA + 10 mA/A 1.8 µA + 5.6 mA/A 16 µA + 5.6 mA/A 0.18 mA + 5.5 mA/A 0.41 mA + 0.5 mA/A 2.3 mA + 0.72 mA/A 0.28 mA + 0.67 mA/A 2.4 mA + 1.9 mA/A 0.45 mA + 2.5 mA/A 3458A Fluke 8508A Distortion3 – Measure 20 Hz to 20 kHz (20 to 100) kHz 100 kHz to 3 GHz (3 to 6.5) GHz (6.5 to 21.9) GHz (21.9 to 50) GHz 1.2 dB 2.3 dB 0.54 dB 1.8 dB 2.4 dB 3.0 dB 8903A E4448A
25-Frequency Response; Phase; Synchro – Measuring Equipment; Resolver – Measuring Equipment
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 25 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Frequency Response3 – Measure 1 MHz 2 MHz 10 MHz 20 MHz 30 MHz 50 MHz 100 MHz 0.095 % 0.16 % 0.16 % 0.28 % 0.29 % 0.6 % 1.2 % Ballantine 1395B-1 TVC Phase – Measure3 (10 to 32) mV 32 mV to 100 V (100 to 120) V (10 to 32) mV 32 mV to 100 V (10 to 32) mV 32 mV to 100 V (10 to 32) mV 32 mV to 100 V 10 Hz to 5 kHz (5 to 10) kHz (10 to 50) kHz (50 to 100) kHz 0.23 ° 0.059 ° 0.12 ° 0.23 ° 0.059 ° 0.23 ° + 0.0043 °/kHz above 10 kHz 0.059 ° 0.4 ° + 0.0081 °/kHz above 50 kHz 0.06 ° + 0.0069 °/kHz above 50 kHz Krohn-Hite 6620 Synchro – Measuring Equipment 3 (47 to 800) Hz See Matrix below North Atlantic 5300 Frequency (6 to 11.8) VLL (> 11.8 to 50) VLL (> 50 to 90) VLL (47 to 360) Hz ---- 0.000 97 ° 0.0011 ° (> 360 to 600) Hz 0.000 66 ° 0.000 66 ° 0.00097 ° (> 600 to 800) Hz 0.000 66 ° 0.000 97 ° 0.0013 ° Resolver – Measuring Equipment3 (360 to 800) Hz See Matric Below North Atlantic 5300 Frequency (6 to 26) VLL (> 26 to 90) VLL (360 to 600) Hz 0.000 66 ° 0.000 66 ° (> 600 to 800) Hz 0.000 66 ° 0.000 66 °
-
26

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 26 of 40 Parameter/Range Frequency CMC2, 4 (±) Comments Phase3 – Generate (PF=1) (10 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (3 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz Ø 0.1 ° Ø 0.26 ° Ø 0.51 ° Ø 2.6 ° Ø 5.1 ° Ø 10 ° Ø 0.1 ° Ø 0.2 ° Ø 0.4 ° Ø 1.9 ° Ø 3.9 ° Ø 7.8 ° Fluke 5520A Fluke 5560A IV. Electrical – RF/Microwave Parameter/Range Frequency CMC2, 4, 5 (±) Comments Absolute Power – Measure3 (0 to +20) dBm (-10 to 0) dBm (-60 to -10) dBm (-70 to +20) dBm (-30 to +20) dBm 100 mW to 2 kW 100 mW to 500 W 9 kHz to 16 GHz (16 to 18) GHz 9 kHz to 16 GHz (16 to 18) GHz 9 kHz to 2 GHz (2 to 16) GHz (16 to 18) GHz (19 to 26.5) GHz (26.5 to 33) GHz (33 to 35) GHz (36 to 40) GHz (41 to 47) GHz (48 to 50) GHz 10 kHz to 250 MHz 10 kHz to 6 GHz 2.6 % 2.8 % 3.1 % 3.3 % 3.6 % 3.7 % 3.8 % 4.1 % 4.3 % 4.5 % 4.7 % 5.1 % 5.6 % 1.7 % 1.7 % E4418B, E9304A-H18 E4418B, E4413A E4418B, 8487A E4418B, E9304A, couplers & attenuators
27

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 27 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Displayed Average Noise Level (DANL), (-165 to -50) dBm DC to 4 GHz (> 4 to 20) GHz (> 20 to 26.5) GHz (> 26.5 to 50) GHz 0.39 dB 0.67 dB 0.59 dB 1.3 dB 50 Ω termination Single Sideband Phase Noise – Measure Offset 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 10 MHz 100 MHz 1 MHz to 50 GHz 4.4 dB 3.2 dB 2.8 dB 2.9 dB 2.6 dB 2.4 dB 2.4 dB 2.5 dB Agilent E4448A Single Sideband measurement capability is limited by the phase noise performance of the standard at center frequencies being measured. Below is the typical maximum measurement range that can be expected of this standard. Offset Frequency Up to 600 MHz (0.6 to 10.2) GHz (10.2 to 26.5) GHz (25.2 to 50) GHz 10 Hz -105 dBc/Hz -85 dBc/Hz -76 dBc/Hz -70 dBc/Hz 100 Hz -105 dBc/Hz -85 dBc/Hz -76 dBc/Hz -70 dBc/Hz 1 kHz -111 dBc/Hz -100 dBc/Hz -92 dBc/Hz -90 dBc/Hz 10 kHz -120 dBc/Hz -112 dBc/Hz -105 dBc/Hz -100 dBc/Hz 100 kHz -125 dBc/Hz -120 dBc/Hz -112 dBc/Hz -105 dBc/Hz 1 MHz -150 dBc/Hz -145 dBc/Hz -138 dBc/Hz -130 dBc/Hz 10 MHz -158 dBc/Hz -150 dBc/Hz -140 dBc/Hz -134 dBc/Hz 100 MHz -158 dBc/Hz -150 dBc/Hz -140 dBc/Hz -134 dBc/Hz Excess Noise Ratio (ENR)3 – Calibrate Noise Sources, Up to 20 dB ENR 10 MHz to 18 GHz (18 to 26.5) GHz 0.52 dB 0.59 dB 346C reference noise source, 8971C noise figure test set, 8970B noise figure meter Absolute Power3 – Generate 100 mW to 500 W 10 kHz to 6 GHz 1.7 % E4418B, E9304A, couplers & attenuators
28-Power
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 28 of 40 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Power Reference3 – Measure Power Meter Accuracy Power Sensor Calibration Factor3 1 mW at 50 MHz 1 mW at 1 GHz 3 µW to 100 mW (9 to 100) kHz 100 kHz to 1.1 GHz (1.1 to 4.6) GHz (4.6 to 10) GHz (10 to 11.8) GHz (11.8 to 16.25) GHz (16.25 to 18) GHz (18 to 26.5) GHz (26.5 to 33) GHz (33 to 38) GHz (38 to 41) GHz (41 to 50) GHz 0.68 % 0.71 % 0.29 % 1.1 % 0.55 % 0.59 % 0.63 % 0.68 % 0.76 % 0.89 % 1.8 % 2.1 % 2.4 % 2.7 % 2.8 % M1110, 1806, 3458A F1109, 1806, 3458A 11683A E4418B w/E9304A Tegam 1806A w/F1130B & F1135B, 3458A E4418B w/N8487A Relative Power3 – Measure (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB (-120 to -127) dB (0 to -10) dB (-10 to -20) dB (-20 to -30) dB (-30 to -40) dB (-40 to -50) dB (-50 to -60) dB (-60 to -70) dB (-70 to -80) dB (-80 to -90) dB (-90 to -100) dB (-100 to -110) dB (-110 to -120) dB (-120 to -127) dB 2.5 MHz to 1.3 GHz (1.3 to 26.5) GHz 0.047 dB 0.06 dB 0.074 dB 0.087 dB 0.1 dB 0.1 dB 0.11 dB 0.12 dB 0.13 dB 0.15 dB 0.15 dB 0.28 dB 0.29 dB 0.066 dB 0.06 dB 0.074 dB 0.087 dB 0.1 dB 0.1 dB 0.11 dB 0.12 dB 0.13 dB 0.15 dB 0.15 dB 0.28 dB 0.29 dB 8902A
-
29

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 29 of 40 Parameter/Range Frequency CMC2, 4 (±) Comments Amplitude Modulation3 – Measure Rate: 50 Hz to 10 kHz Depths: (5 to 99) % Rate: 20 Hz to 10 kHz Depths: To 99 % Rate: 50 Hz to 50 kHz Depths: (5 to 99) % Rate: 20 Hz to 100 kHz Depths: To 99 % Rate: 50 Hz to 50 kHz Depths: (5 to 99) % Rate: 20 Hz to 100 kHz Depths: To 99 % 150 kHz to 10 MHz 150 kHz to 10 MHz (0.01 to 1.3) GHz (0.01 to 1.3) GHz (1.3 to 26.5) GHz (1.3 to 26.5) GHz 0.14 % depth + 0.024 % depth/% depth 0.11 % depth + 0.023 % depth/% depth 0.15 % depth + 0.01 % depth/% depth 0.11 % depth + 0.023 % depth/% depth 0.33 % depth + 0.008 % depth/% depth 0.31 % depth + 0.021 % depth/% depth 8902A Frequency Modulation3 – Measure Rate: 20 Hz to 10 kHz Dev.: ≤ 40 kHz Peak Rate: 50 Hz to 100 kHz Dev.: ≤ 400 kHz Peak Rate: 20 Hz to 200 kHz Dev.: ≤ 400 kHz Peak Rate: 50 Hz to 100 kHz Dev.: ≤ 400 kHz Peak Rate: 20 Hz to 200 kHz Dev.: ≤ 400 kHz Peak 250 kHz to 10 MHz (0.01 to 1.3) GHz (0.01 to 1.3) GHz (1.3 to 26.5) GHz (1.3 to 26.5) GHz 3.5 Hz + 16 Hz/kHz 3.5 Hz + 7.8 Hz/kHz 6.8 Hz + 39 Hz/kHz 6.8 Hz + 7.8 Hz/kHz 6.8 Hz + 39 Hz/kHz 8902A Phase Modulation3 – Measure Rate: 200 Hz to 10 kHz (0 to 100) rad Rate: 200 Hz to 20 kHz (0 to 100) rad Rate: 200 Hz to 20 kHz (0 to 100) rad 150 kHz to 10MHz (0.01 to 1.3) GHz (1.3 to 26.5) GHz 36 mrad + 37 mrad/rad 36 mrad + 37 mrad/rad 36 mrad + 37 mrad/rad 8902A
30-S-Parameters (Reflection & Transmission)
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 30 of 40 Parameter/Range Frequency CMC2 (±) Comments S-Parameters (Reflection & Transmission)3 45 MHz to 6 GHz See tables below (Interpolate CMC’s between cardinal points listed) Network analyzers with calibration/ verification kits Type N: Reflection S11/S22 Linear Magnitude (ρ) 8753E with 85032B rho 30 kHz to 1.3 GHz (1.3 to 3) GHz (3 to 6) GHz 0 0.0039 0.0051 0.011 0.1 0.0046 0.0061 0.012 0.2 0.0054 0.0072 0.014 0.3 0.0063 0.0086 0.017 0.4 0.0073 0.01 0.02 0.5 0.0085 0.012 0.024 0.6 0.0098 0.014 0.028 0.7 0.011 0.017 0.033 0.8 0.013 0.02 0.038 0.9 0.015 0.023 0.044 1.0 0.017 0.026 0.05 Type N: Reflection S11/S22 Phase (°) 8753E with 85032B rho 30 kHz to 1.3 GHz (1.3 to 3) GHz (3 to 6) GHz 0 --- --- --- 0.1 2.6 3.5 7 0.2 1.5 2.1 4.1 0.3 1.2 1.7 3.3 0.4 1.1 1.5 2.9 0.5 1 1.4 2.7 0.6 0.96 1.4 2.7 0.7 0.94 1.4 2.7 0.8 0.94 1.4 2.7 0.9 0.94 1.4 2.8 1.0 0.95 1.5 2.9 Type N: Transmission S12/S21 Linear Magnitude (dB) 8753E with 85032B dB 30 kHz to 1.3 GHz (1.3 to 3) GHz (3 to 6) GHz -90 6.1 6.4 8.8 -80 2.4 2.6 3.8 -70 0.85 0.91 1.4 -60 0.3 0.32 0.5 -50 0.13 0.14 0.21 -40 0.088 0.1 0.15 -30 0.074 0.087 0.13 -20 0.063 0.076 0.12 -10 0.053 0.066 0.11
See scope document
31-S-Parameters (Reflection & Transmission)
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 31 of 40 Parameter/Range Frequency CMC2 (±) Comments S-Parameters (Reflection & Transmission)3 45 MHz to 6 GHz See tables below (Interpolate CMC’s between cardinal points listed) Network analyzers with calibration/ verification kits Type N: Transmission S12/S21 Linear Magnitude (dB) 8753E with 85032B dB 30 kHz to 1.3 GHz (1.3 to 3) GHz (3 to 6) GHz 0 0.042 0.055 0.094 10 0.076 0.089 0.15 Type N: Transmission S12/S21 Phase (°) 8753E with 85032B dB 30 kHz to 1.3 GHz (1.3 to 3) GHz (3 to 6) GHz -90 ---- ---- ---- -80 19 20 34 -70 5.9 6.3 10 -60 2 2.2 3.4 -50 0.89 0.98 1.5 -40 0.62 0.71 1 -30 0.53 0.61 0.88 -20 0.46 0.54 0.8 -10 0.39 0.48 0.73 0 0.29 0.38 0.63 10 0.8 0.88 1.2 S-Parameters (Reflection & Transmission) 3 45 MHz to 18 GHz See tables below (Interpolate CMC’s between cardinal points listed) Network analyzers with calibration/ verification kits Type N: Reflection S11/S22 Linear Magnitude (ρ) 8510C with 85054D rho 45 MHz to 2 GHz (2 to 8) GHz (8 to 18) GHz 0 0.01 0.016 0.02 0.1 0.01 0.016 0.02 0.2 0.01 0.016 0.02 0.3 0.01 0.016 0.02 0.4 0.01 0.016 0.021 0.5 0.011 0.017 0.022 0.6 0.011 0.018 0.024 0.7 0.012 0.02 0.027 0.8 0.013 0.022 0.031 0.9 0.014 0.024 0.036 1.0 0.016 0.028 0.041
See scope document
32-S-Parameters (Reflection & Transmission)
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 32 of 40 Parameter/Range Frequency CMC2 (±) Comments S-Parameters (Reflection & Transmission) 3 45 MHz to 18 GHz See tables below (Interpolate CMC’s between cardinal points listed) Network Analyzers with calibration/ verification kits Type N: Reflection S11/S22 Phase (°) 8510C with 85054D rho 45 MHz to 2 GHz (2 to 8) GHz (8 to 18) GHz 0 ---- ---- ---- 0.1 5.9 9.3 12 0.2 3 4.7 6 0.3 2 3.2 4.2 0.4 1.6 2.5 3.3 0.5 1.3 2.1 2.8 0.6 1.2 1.9 2.6 0.7 1.1 1.8 2.5 0.8 1 1.7 2.5 0.9 1 1.8 2.6 1.0 1 1.8 2.7 Type N: Transmission S12/S21 Linear Magnitude (dB) 8510C with 85054D dB 45 MHz to 2 GHz (2 to 8) GHz (8 to 18) GHz -70 0.64 0.82 1.1 -60 0.21 0.28 0.37 -50 0.074 0.089 0.14 -40 0.04 0.046 0.097 -30 0.033 0.034 0.083 -20 0.031 0.034 0.082 -10 0.03 0.032 0.082 0 0.023 0.031 0.081 10 0.18 0.1 0.11
See scope document
33-S-Parameters
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 33 of 40 Parameter/Range Frequency CMC2, 5 (±) Comments S-Parameters (Reflection & Transmission) 3 45 MHz to 18 GHz See tables below (Interpolate CMC’s between cardinal points listed) Network Analyzers with calibration/ verification kits Type N: Transmission S12/S21 Phase (°) 8510C with 85054D dB 45 MHz to 2 GHz (2 to 8) GHz (8 to 18) GHz -70 4.2 5.3 7.2 -60 1.5 1.9 2.7 -50 0.59 0.76 1.2 -40 0.37 0.47 0.9 -30 0.31 0.4 0.84 -20 0.3 0.39 0.83 -10 0.29 0.38 0.82 0 0.24 0.37 0.82 10 1.3 0.84 1 S-Parameters (Reflection & Transmission) 3 45 MHz to 26.6 GHz See tables below (Interpolate CMC’s between cardinal points listed) Network analyzers with calibration/ verification kits Type 3.5 mm: Reflection S11/S22 Linear Magnitude (ρ) 8510C with 85052B rho 45 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz 0 0.0081 0.013 0.016 0.032 0.1 0.0081 0.013 0.016 0.032 0.2 0.0081 0.013 0.016 0.032 0.3 0.0082 0.03 0.016 0.032 0.4 0.0084 0.014 0.017 0.033 0.5 0.0089 0.015 0.019 0.035 0.6 0.0096 0.016 0.021 0.037 0.7 0.011 0.019 0.025 0.046 0.8 0.012 0.022 0.029 0.046 0.9 0.014 0.026 0.034 0.053 1.0 0.016 0.031 0.041 0.062 Type 3.5 mm: Reflection S11/S22 Phase (°) 8510C with 85052B rho 45 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz 0 53 ---- ---- ---- 0.1 4.7 7.4 9.4 19 0.2 2.4 3.8 4.9 9.5 0.3 1.7 2.6 3.4 6.5 0.4 1.3 2.1 2.7 5.1 0.5 1.1 1.8 2.4 4.3 0.6 1 1.7 2.3 3.9
See scope document
34-S-Parameters (Reflection & Transmission)
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 34 of 40 Parameter/Range Frequency CMC2, 5 (±) Comments S-Parameters (Reflection & Transmission) 3 45 MHz to 26.6 GHz See tables below (Interpolate CMC’s between cardinal points listed) Network analyzers with calibration/ verification kits Type 3.5 mm: Reflection S11/S22 Phase (°) 8510C with 85052B rho 45 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz 0.7 0.97 1.7 2.3 3.7 0.8 0.97 1.8 2.4 3.7 0.9 1 1.9 2.5 3.8 1.0 1 2 2.7 4 Type 3.5 mm: Transmission S12/S21 Linear Magnitude (dB) 8510C with 85052B dB 45 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz -70 0.64 0.82 1.2 5.2 -60 0.21 0.28 0.39 1.5 -50 0.074 0.089 0.14 0.43 -40 0.04 0.046 0.094 0.21 -30 0.032 0.035 0.079 0.16 -20 0.03 0.034 0.078 0.15 -10 0.029 0.033 0.077 0.15 0 0.023 0.031 0.077 0.15 10 0.022 0.031 0.077 0.15 Type 3.5 mm: Transmission S12/S21 Phase (°) 8510C with 85052B dB 45 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz -70 4.2 5.3 7.6 27 -60 1.5 1.9 2.8 9.9 -50 0.59 0.76 1.2 3.1 -40 0.37 0.47 0.9 1.7 -30 0.31 0.4 0.83 1.4 -20 0.29 0.4 0.82 1.4 -10 0.29 0.39 0.81 1.4 0 0.24 0.38 0.81 1.4 10 0.23 0.38 0.81 1.4
See scope document
35-S-Parameters (Reflection & Transmission)
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 35 of 40 Parameter/Range Frequency CMC2, 5 (±) Comments S-Parameters (Reflection & Transmission) 3 (2 to 50) GHz See tables below (Interpolate CMC’s between cardinal points listed) Network analyzers with calibration/ verification kits Type 2.4 mm: Reflection S11/S22 Linear Magnitude (ρ) 8510C with 85056D rho (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz (26.5 to 50) GHz 0 0.0081 0.013 0.016 0.032 0.1 0.0081 0.013 0.016 0.032 0.2 0.0081 0.013 0.016 0.032 0.3 0.0082 0.03 0.016 0.032 0.4 0.0084 0.014 0.017 0.033 0.5 0.0089 0.015 0.019 0.035 0.6 0.0096 0.016 0.021 0.037 0.7 0.011 0.019 0.025 0.046 0.8 0.012 0.022 0.029 0.046 0.9 0.014 0.026 0.034 0.053 1.0 0.016 0.031 0.041 0.062 Type 2.4 mm: Reflection S11/S22 Phase (°) 8510C with 85056D rho 45 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz 0 ---- ---- ---- ---- 0.1 7.4 9.4 19 31 0.2 3.8 4.9 9.5 15 0.3 2.6 3.4 6.5 11 0.4 2.1 2.7 5.1 8.3 0.5 1.8 2.4 4.3 7 0.6 1.7 2.3 3.9 6.4 0.7 1.7 2.3 3.7 6.1 0.8 1.8 2.4 3.7 6.1 0.9 1.9 2.5 3.8 6.2 1.0 2 2.7 4 6.5 Type 2.4 mm: Transmission S12/S21 Linear Magnitude (dB) 8510C with 85056D dB 45 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz -70 0.82 1.2 5.2 8.8 -60 0.28 0.39 1.5 2.5 -50 0.089 0.14 0.43 0.73 -40 0.046 0.094 0.21 0.36 -30 0.035 0.079 0.16 0.27 -20 0.034 0.078 0.15 0.27 -10 0.033 0.077 0.15 0.27 0 0.031 0.077 0.15 0.27
2 to 50 GHz
36-Fiber Optic
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 36 of 40 Parameter/Range Frequency CMC2, 5 (±) Comments S-Parameters (Reflection & Transmission) 3 (2 to 50) GHz See tables below (Interpolate CMC’s between cardinal points listed) Network analyzers with calibration/ verification kits Type 2.4 mm: Transmission S12/S21 Linear Magnitude (dB) 8510C with 85056D dB 45 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz 10 0.031 0.077 0.15 0.27 Type 2.4 mm: Transmission S12/S21 Phase (°) 8510C with 85056D dB 45 MHz to 2 GHz (2 to 8) GHz (8 to 20) GHz (20 to 26.5) GHz -70 5.3 7.6 27 46 -60 1.9 2.8 9.9 17 -50 0.76 1.2 3.1 5.3 -40 0.47 0.9 1.7 2.9 -30 0.4 0.83 1.4 2.4 -20 0.4 0.82 1.4 2.4 -10 0.39 0.81 1.4 2.4 0 0.38 0.81 1.4 2.4 10 0.38 0.81 1.4 2.4 V. Optical Quantities Parameter/Equipment Range CMC2, 7 (±) Comments Fiber Optic3 Power – Measuring Equipment & Measure: (800 to 1000) nm (1000 to 1650) nm Wavelength – Measuring Equipment & Measure Linearity (1310 to 1550) nm OTDR Length 3 (-80 to +10) dBm (-90 to +10) dBm (600 to 1270) nm (1270 to 1650) nm (1310 & 1550) nm (0 to 60) dB 300 ft 0.15 dB 0.1 dB 0.59 nm 0.093 nm 0.58 nm 0.15 dB 0.17 ft 81634A power sensor 81624B power sensor 86142B optical spectrum analyzer 86120C multiwavelength multimeter 81654C laser source 8156A optical attenuator, 81654A laser source Calibrated fiber optic cable
2 to 50 GHz
37

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 37 of 40 Parameter/Equipment Range CMC2, 7 (±) Comments Irradiance Up to 4000 W/m2 1.4 % Pyranometer VI. Mechanical Parameter/Equipment Range CMC2, 5, 7 (±) Comments Balances3 (1 to 500) g Matrix value x R Class 6 weights Unit Under Test Resolution 0.001 g 0.01 g 0.1 g 1 g 1 g 0.83 2 g 0.85 5 g 1.0 10 g 1.5 0.83 0.83 20 g 2.5 0.85 50 g 1.0 100 g 1.5 0.83 200 g 2.5 0.85 500 g 1.0 Torque Equipment3 (2 to 200) ozf·in (1 to 10) lbf·in (5 to 50) lbf·in (40 to 400) lbf·in (100 to 1000) lbf·in (25 to 250) lbf·ft (60 to 600) lbf·ft (650 to 2000) lbf·ft 2.3 % 2.3 % 0.3 % 0.3 % 0.31 % 0.3 % 0.29 % 0.65 % CDI Suretest system Scales3 Up to 1000 lb 0.82 x R Class 6 weights Force3 – Measure & Measuring Equipment (0 to 200) lbf (200 to 1000) lbf (1000 to 10 000) lbf 0.42 lbf 2.9 lbf 22 lbf Mark-10 load cells
38-Pneumatic Measuring Equipment; Avionics Instrumentation; Temperature; Humidity
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 38 of 40 Parameter/Equipment Range CMC2, 5, 7 (±) Comments Pressure Gages, Transducers & Calibrators – Measure & Measuring Equipment3 Pneumatic Measure Pneumatic Measuring Equipment (-14.6 to 0) psig (1 to 15) psia (0 to 30) psig (30 to 100) psig (100 to 1000) psig (1000 to 5000) psig (5000 to 10 000) psig (-12 to 100) psig 0.013 psi 0.0092 psi 0.017 psi 0.047 psi 0.46 psi 5.8 psi 9.6 psi 0.041 psi Fluke 700PV4 Fluke 700PA4 Fluke 700P05 Fluke 750R06 Fluke 750R08 Fluke 700P30 Fluke 700P31 Fluke 719 Avionics Instrumentation3 Altitude Air Speed (-2000 to 80 000) ft (0 to 1050) knots 3.7 ft + 0.085 % 0.058 knots + 0.013 % Raptor Scientific PPCM Avionics Instrumentation 3 Altitude Air Speed Up to 60 000 ft (0 to 32) inHg Up to 50 knots (> 50 to 1000) knots (0 to 68) inHg 3.4 ft + 0.02 % 0.000 92 inHg + 0.0067 % 0.25 knots 0.16 knots 0.0019 inHg + 0.0066 % Fluke 7750i VII. Thermodynamics Parameter/Equipment Range CMC2, 7 (±) Comments Temperature3 – Measure (-197 to 660) °C 0.012 °C + 0.000 062 °C/°C Fluke 5626 PRT, 3458A Humidity3 – Measuring Equipment (10 to 90) % RH 1.1 % RH Rotronic HP32 w/ HCA2A probe
See scope document
39AMS 2750F--
40

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2737.02) Revised 7/30/2026 Page 40 of 40 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, ( e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percentage or fraction of the reading plus a fixed floor specification. 5 In the statement of CMC uncertainty, the value is defined as the percentage of reading unless otherwise indicated; L represents the length of displacement in inches and R represents the resolution of the unit under test. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
41ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ELIZABETH CITY, NC, US

36.30102, -76.22037

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.