SP HB Instrument Calibration Laboratory

2024/2028 Broad Street, 21851, Pocomoke City, MD, United States

Visit website
A2LA 2448.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 2448.01 · 3 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994Alcohol solution; Sodium polytungstate solution or alcohol/water solution or petroleum ether/alcohol solution0 to 206 % Proof Spirit
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2448.01) 07/28/2026 Page 2 of 2 II. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Thermometers – Liquid-in-Glass, Electronic, Bi Metal (-80 to -1) °C 0 °C (1 to 100) °C (101 to 200) °C (201 to 300) °C (301 to 400) °C 0.027 °C 0.015 °C 0.019 °C 0.020 °C 0.021 °C 0.028 °C Accumac, Additel III. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Digital Stopwatch & Timers (Type I) (2 to 120) s/day 0.43 s/day TM-4500 vibrograph ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The definition and identification of the hydrometer scale graduations follow the NBS Circular 555. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
3ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.