SIMCO Electronics - Hampton

144 Research Drive, Suite A, 23666, Hampton, VA, United States

Visit website
A2LA 1395.15ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
18
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 18 scope lines.

A2LA certificate 1395.15 · 18 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994Sound Pressure Level; Acoustic Calibrators; Acoustic Level; Pistonphones74 to 130 dB
2-Microphone
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 2 of 17 Parameter/Equipment Range CMC2 (±) Comments Microphone Open Circuit Sensitivity – Microphone Electrostatic Response Weighting Networks – A B C D Linear Microphone Preamp Frequency Response (-60 to -24) dB re 1V/Pa 1” Microphone ½” Microphone ¼” Microphone (0.02 to 2) kHz (2 to 6.309) kHz (6.309 to 20) kHz (20 to 80) kHz Frequency: 10 Hz to 20 kHz Frequency: 10 Hz to 20 kHz Frequency: 10 Hz to 20 kHz Frequency: 10 Hz to 20 kHz Frequency: 1 Hz to 200 kHz (1 to 200 000) Hz 0.035 dB re 1V/Pa 0.074 dB re 1V/Pa 0.031 dB re 1V/Pa 0.17 dB 0.19 dB 0.22 dB 0.31 dB 0.013 dB 0.0041 dB 0.0019 dB 0.0055 dB 0.0019 dB 0.0074 dB HBK 4228 HBK 4160 1.0” HBK 4191 0.5” HBK 4938 0.25” NI PXI-4462 HBK 5001, 5935L HP 3325B NI PXI-4462 Mensor 15000 NI PXI-4462 HP 3325B HP 3458A HP 3325B HP 3458A II. Dimensional Parameter/Equipment Range CMC2, 6 (±) Comments Calipers3 Up to 20 in (20 to 60) in (7.6 + 20L) µin (7.6 + 38L) µin Gage blocks, master rings Micrometers3 – Linearity Flatness Parallelism Up to 36 in Up to 1 in Ø 9 (0.5 to 1) in (8.9 + 5.4L) µin 6.5 µin 24 µin Gage blocks Optical flats Ball checker set
1 to 200000 Hz
3-Threaded Plugs; Cylindrical Gages; Gage Blocks; Ring Gages; Length Standards
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 3 of 17 Parameter/Equipment Range CMC2, 6 (±) Comments Threaded Plugs – Major Diameter Pitch Diameter Up to 12 in Up to 12 in, (4 to 80) TPI (19 + 4.1L) µin (68 + 3.7L) µin P&W USM, gage blocks Thread wires Linear Indicators (Dial, Test, LVDT’s) Up to 2 in 22 µin P&W USM Flatness Up to 1 in Ø9 6.5 µin Optical flats Cylindrical Gages (Plain Pins, Plugs, Discs) Up to 12 in (7.0 + 2.6L) µin P&W USM, gage blocks Gage Blocks Up to 0.04 in (0.04 to 4) in (4 to 24) in (2.0 + 1.9L) µin (1.3 + 1.6L) µin (2.9 + 1.5L) µin Federal 130B-24 master gage blocks Height Gages³ Up to 48 in (31 + 2.6L) µin Gage blocks Ring Gages (0.125 to 0.25) in (0.250 to 1) in (1 to 10) in (7.7 + 2.5L) µin (7.4 + 3.5L) µin (17 + 3.2L) µin P&W USM, gage blocks Length Standards (0.5 to 8) in (11 + 2.4L) µin P&W USM, gage blocks Linear Scale Measurement Up to 48 in increments (32 + 0.58L) µin Laser interferometer Thread Wires (4 to 80) TPI 8.8 µin P&W USM, gage blocks or master cylinders
-
4-Surface Plates; DC Voltage; DC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 4 of 17 Parameter/Equipment Range CMC2, 6 (±) Comments Surface Plates3 – Flatness Repeat Reading Up to 7 ft diagonal (36 x 36) in (6.7 + 0.58D) µin 28 µin Renishaw XL-80 LI Renishaw XC-80 TC Angular optics/straight edge Repeatmeter III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 5, 6 (±) Comments DC Voltage – Generate3 (0 to 220) mV 220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1000) V 8.7 µV/V + 0.4 µV 5.9 µV/V + 0.71 µV 4.2 µV/V + 2.8 µV 4.2 µV/V + 4.2 µV 5.9 µV/V + 42 µV 7.7 µV/V + 420 µV Fluke 5720A DC Voltage – Measure3 Digitize – Measure 3 (0 to 202) mV (0.202 to 2.02) V (2.02 to 20.2) V (20.2 to 202) V (202 to 1050) V (0 to 1050) V 7.7 µV/V + 0.23 µV 3 µV/V + 0.35 µV 2.9 µV/V + 0.58 µV 4.7 µV/V + 35 µV 5 µV/V + 580 µV 57 µV/V + 31 mV Fluke 8588A DC Current – Generate3 (0 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (0.22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (11 to 20.5) A (20 to 149.999) A (150 to 1025) A 48 µA/A + 6.0 nA 43 µA/A + 7.0 nA 43 µA/A + 40 nA 54 µA/A + 0.7 µA 93 µA/A + 12 µA 0.38 mA/A + 0.37 mA 0.81 mA/A + 0.75 mA 0.36 % 0.35 % Fluke 5720A 55XXA [2] Floor spec. doubles >30 seconds Fluke 55XXA, Fluke 5500A/COIL
-
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 5 of 17 Parameter/Equipment Range CMC2, 5, 6 (±) Comments DC Current – Measure3 Digitize – Measure3 Shunt – Measure 3, 4 (0 to 20.2) µA (20.2 to 202) µA (0.202 to 2.02) mA (2.02 to 20.2) mA (20.2 to 202) mA (0.202 to 2.02) A (2.02 to 20.2) A (20.2 to 30.2) A (0 to 202) mA (0.202 to 2.02) A (2.02 to 20.2) A (20.2 to 30.2) A (20 to 100) A 28 µA/A + 4.6 pA 9.5 µA/A + 0.46 nA 8.8 µA/A + 4.6 nA 10 µA/A + 46 nA 38 µA/A + 1.2 µA 120 µA/A + 120 µA 200 µA/A + 0.46 mA 570 µA/A + 5.1 mA 55 µA/A + 9.2 µA 130 µA/A + 140 µA 210 µA/A + 2.4 mA 580 µA/A + 8 mA 0.023 % Fluke 8588A Fluke 5522A, L&N 4221B, Fluke 8588A Resistance – Generate3 (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω 330 Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ 330 Ω to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ 330 MΩ to 1.1 GΩ 31 µΩ/Ω + 0.000 78 Ω 23 µΩ/Ω + 0.0012 Ω 22 µΩ/Ω + 0.0011 Ω 22 µΩ/Ω + 0.0016 Ω 22 µΩ/Ω + 0.0016 Ω 22 µΩ/Ω + 0.016 Ω 22 µΩ/Ω + 0.016 Ω 22 µΩ/Ω + 0.16 Ω 22 µΩ/Ω + 0.16 Ω 25 µΩ/Ω + 1.6 Ω 25 µΩ/Ω + 1.6 Ω 47 µΩ/Ω + 23 Ω 0.010 % + 39 Ω 0.019 % + 1.9 kΩ 0.039 % + 2.3 kΩ 0.23 % + 0.078 MΩ 1.2 % + 0.39 MΩ Fluke 55XXA
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 6 of 17 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Resistance – Generate3 Fixed Points 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 54 µΩ 95 µΩ/Ω + 11 µΩ 50 µΩ/Ω + 11 µΩ 2.3 µΩ/Ω + 11 µΩ 1.2 µΩ/Ω + 11 µΩ 0.1 µΩ/Ω + 11 µΩ 0.053 µΩ/Ω + 82 µΩ 8.5 µΩ/Ω + 82 µΩ 4.5 µΩ/Ω + 0.82 mΩ 0.85 µΩ/Ω + 0.82 mΩ 0.45 µΩ/Ω + 8.2 mΩ 0.11 µΩ/Ω + 8.2 mΩ 0.058 µΩ/Ω + 82 mΩ 20 µΩ/Ω + 82 mΩ 11 µΩ/Ω + 0.82 Ω 4 µΩ/Ω + 0.82 Ω 2.5 µΩ/Ω + 8.2 Ω 1.0 µΩ/Ω + 8.2 Ω Fluke 5720A Resistance – Measure3 (0 to 2.02) Ω (2.02 to 20.2) Ω (20.2 to 202) Ω (0.202 to 2.02) kΩ (2.02 to 20.2) kΩ (20.2 to 202) kΩ (0.202 to 2.02) MΩ (2.02 to 20.2) MΩ (20.2 to 202) MΩ (0.202 to 2.02) GΩ (202 to 20.2) GΩ 13 µΩ/Ω + 4.6 µΩ 8.9 µΩ/Ω + 16 µΩ 8.3 µΩ/Ω + 58 µΩ 8.2 µΩ/Ω + 580 µΩ 8.3 µΩ/Ω + 5.8 mΩ 8.4 µΩ/Ω + 58 mΩ 9.5 µΩ/Ω + 1.2 Ω 13 µΩ/Ω + 120 Ω 45 µΩ/Ω + 12 kΩ 580 µΩ/Ω + 1.2 MΩ 610 µΩ/Ω + 12 MΩ Fluke 8588A Capacitance – Generate3 (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.999) nF (33 to 109.99) nF (110 to 329.99) nF (0.33 to 1.0999) µF (1.1 to 3.2999) µF (3.3 to 10.999) µF (11 to 32.999) µF (33 to 109.99) µF (110 to 329.99) µF (0.33 to 1.0999) mF 0.48 % + 0.0097 nF 0.41 % + 0.0097 nF 0.39 % + 0.0097 nF 0.23 % + 0.015 nF 0.19 % + 0.078 nF 0.21 % + 0.078 nF 0.20 % + 0.23 nF 0.20 % + 0.0058 µF 0.20 % + 0.0062 µF 0.20 % + 0.0097 µF 0.33 % + 0.024 µF 0.42 % + 0.078 µF 0.36 % + 0.23 µF 0.35 % + 0.0058 mF Fluke 55XXA
7-capacitance; oscilloscopes; sine amplitude; sine flatness; square wave; time marker output; edge rise time
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 7 of 17 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Capacitance – Measure3 (0 to 2.02) nF (2.02 to 20.2) nF (20.2 to 202) nF (0.202 to 2.02) µF (2.02 to 20.2) µF (20.2 to 202) µF (0.202 to 2.02) mF (2.02 to 20.2) mF (20.2 to 202) mF 1200 µF/F + 1.2 pF 700 µF/F + 2.3 pF 470 µF/F + 10 pF 470 µF/F + 0.12 nF 470 µF/F + 1.2 nF 700 µF/F + 12 nF 700 µF/F + 0.12 µF 810 µF/F + 1.2 µF 810 µF/F + 12 µF Fluke 8588A Oscilloscopes3 – Level Sine Amp – 50 kHz Reference Level Sine Flatness – 5 mV to 5.5 V Relative to 50 kHz Reference Square Wave – (0.010 to 10) kHz Into 50 Ω Into 1 MΩ, 1 kHz Into 1 MΩ, >1 kHz DC Into 50 Ω Into 1 MΩ Time Marker Output into 50 Ω Edge Rise Time 5 mV to 5.5 Vp-p 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 1 mV to 6.6 V p-p 1 mV to 130 Vp-p 1 mV to 130 Vp-p (0 to 6.6) Vp-p (0 to 130) Vp-p 20 ns to 20 ms (0.05 to 5) s 1 kHz to 10 MHz 1.6 % of output 1.2 % of output 1.6 % of output 3.1 % of output 4.7 % of output 0.25 % of output 0.10 % of output 0.25 % of output 2.6 mV 0.51 mV 2.5 parts in 10 6 51 parts in 104 40 ps Fluke 55XXA
0 to 130 Vp-p
8-thermocouples
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 8 of 17 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples3 – Type E Type J Type K Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.40 °C 0.14 °C 0.13 °C 0.14 °C 0.18 °C 0.25 °C 0.17 °C 0.15 °C 0.15 °C 0.20 °C 0.28 °C 0.16 °C 0.14 °C 0.24 °C 0.32 °C 0.51 °C 0.20 °C 0.14 °C 0.13 °C Fluke 55XXA Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate3 (0.22 to 2.2) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1MHz 0.024 % + 4 µV 0.0090 % + 4 µV 0.0080 % + 4 µV 0.020 % + 4 µV 0.050 % + 5 µV 0.11 % + 10 µV 0.14 % + 20 µV 0.27 % + 20 µV Fluke 5720A
-
9-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 9 of 17 Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Generate3 (cont) (2.2 to 22) mV (22 to 220) mV 220 mV to 2.2 V (2.2 to 22) V (22 to 220) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.025 % + 4 µV 0.0090 % + 4 µV 0.0080 % + 4 µV 0.020 % + 4 µV 0.050 % + 5 µV 0.11 % + 10 µV 0.14 % + 20 µV 0.27 % + 20 µV 0.024 % + 12 µV 0.0090 % + 7 µV 0.0080 % + 7 µV 0.022 % + 7 µV 0.048 % + 17 µV 0.095 % + 20 µV 0.16 % + 25 µV 0.33 % + 45 µV 0.024 % + 40 µV 0.0090 % + 15 µV 0.0045 % + 8 µV 0.0075 % + 10 µV 0.012 % + 30 µV 0.044 % + 80 µV 0.11 % + 200 µV 0.18 % + 300 µV 0.024 % + 400 µV 0.0090 % + 150 µV 0.0045 % + 50 µV 0.0075 % + 100 µV 0.013 % + 200 µV 0.031 % + 600 µV 0.11 % + 2 mV 0.17 % + 3.2 mV 0.044 % + 4 mV 0.0090 % + 1.5 mV 0.0052 % + 0.6 mV 0.0080 % + 1 mV 0.020 % + 2.5 mV 0.092 % + 16 mV 0.44 % + 40 mV 0.88 % + 80 mV Fluke 5720A
See scope document
10-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 10 of 17 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage – Generate3 (cont) (220 to 1100) V (220 to 750) V (15 to 40) Hz (40 to 50) Hz 50 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz 0.095 % + 16 mV 0.028 % + 4 mV 0.037 % + 3.5 mV 0.030 % + 6 mV 0.10 % + 11 mV 0.080 % + 11 mV 0.30 % + 45 mV Fluke 5720A Fluke 5725A AC Voltage – Generate3 Wideband Up to 1.1 mV (1.1 to 3) mV (3 to 11) mV (11 to 33) mV (33 to 110) mV (110 to 330) mV (0.33 to 1.1) V (1.1 to 3.5) V 10 Hz to 30 MHz 10 Hz to 30 MHz 10 Hz to 30 MHz 10 Hz to 30 MHz 10 Hz to 30 MHz 10 Hz to 30 MHz 10 Hz to 30 MHz 10 Hz to 30 MHz 0.80 % + 2 µV 0.70 % + 3 µV 0.70 % + 8 µV 0.60 % + 16 µV 0.60 % + 40 µV 0.50 % + 0.1 mV 0.50 % + 0.4 mV 0.40 % + 0.5 mV Fluke 5720A AC Voltage – Generate3 Wideband Flatness Up to 1.1 mV (1.1 to 3) mV 3 mV to 3.5 V (0.30 to 120) kHz (0.120 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (0.30 to 120) kHz (0.120 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz (0.30 to 120) kHz (0.120 to 2) MHz (2 to 10) MHz (10 to 20) MHz (20 to 30) MHz 0.10 % 0.20 % + 3 µV 0.40 % + 3 µV 0.60 % + 3 µV 1.5 % + 15 µV 0.10 % 0.10 % + 3 µV 0.30 % + 3 µV 0.50 % + 3 µV 1.5 % + 3 µV 0.10 % 0.10 % + 3 µV 0.20 % + 3 µV 0.40 % + 3 µV 1.0 % + 3 µV Fluke 5720A
See scope document
11-AC Voltage
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 11 of 17 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage – Measure3 (0.014 to 12.12) mV (12.12 to 121.2) mV 121.2 mV to 12.12 V (12.12 to 121.2) V (121.2 to 1050) V 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (2 to 4) MHz (4 to 8) MHz (8 to 10) MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 250 µV/V + 1.3 µV 330 µV/V + 1.3 µV 340 µV/V + 1.3 µV 0.3 % + 1.3 µV 1.0 % + 4.6 µV 2.0 % + 4.6 µV 68 µV/V + 0.58 µV 110 µV/V + 0.58 µV 210 µV/V + 1.2 µV 510 µV/V + 5.8 µV 0.2 % + 35 µV 1.0 % + 120 µV 1.5 % + 580 µV 4.0 % + 1.2 mV 8.0 % + 1.2 mV 15 % + 1.2 mV 65 µV/V + 58 µV 110 µV/V + 58 µV 210 µV/V + 120 µV 510 µV/V + 580 µV 0.2 % + 3.5 mV 1.0 % + 12 mV 1.5 % + 58 mV 4.0 % + 120 mV 8.0 % + 120 mV 15 % + 120 mV 70 µV/V + 0.58 mV 91 µV/V + 0.58 mV 210 µV/V + 1.2 mV 510 µV/V + 5.8 mV 0.35 % + 58 mV 1.1 % + 580 mV 90 µV/V + 29 mV 91 µV/V + 29 mV 210 µV/V + 29 mV 510 µV/V + 120 mV Fluke 8588A
See scope document
12-AC Current
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 12 of 17 Parameter/Range Frequency CMC2, 5 (±) Comments AC Current – Generate4 @ 60 Hz (20 to 100) A 0.10 % of setting Fluke 5522A w/ Valhalla 2555A AC Current – Generate4 @ 400 Hz (20 to 100) A 0.10 % of setting Fluke 5522A w/ Valhalla 2555A AC Current – Generate3 @ 1kHz (29 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (20 to 100) A (3 to 11) A (11 to 20.5) A 0.13 % + 0.10 µA 0.11 % + 0.20 µA 0.040 % + 3.0 µA 0.039 % + 27 µA 0.051 % + 0.10 mA 0.014 % + 0.59 mA 0.021 % + 2.0 mA 0.048 % + 5.0 mA 0.70 % of setting 0.041 % + 2.1 mA 0.061 % + 5.6 mA Fluke 55XXA Fluke 55XXA w/ Valhalla 2555A Fluke 55XXA AC Current – Measure3 (0.04 to 20.2) µA 20.2 µA to 20.2 mA (20.2 to 202) mA 202 mA to 2.02 A (2.02 to 20.2) A (20.2 to 30.2) A 1 Hz to 30 kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 1 Hz to 10 kHz 1 Hz to 2 kHz (2 to 10) kHz 2000 µA/A + 2.9 nA 260 µA/A + 0.58 µA 510 µA/A + 0.58 µA 720 µA/A + 0.58 µA 4 mA/A + 1.2 µA 260 µA/A + 5.8 µA 500 µA/A + 5.8 µA 700 µA/A + 5.8 µA 260 µA/A + 120 µA 510 µA/A + 120 µA 710 µA/A + 120 µA 800 µA/A + 580 µA 0.8 mA/A + 14 mA 1.2 mA/A + 14 mA Fluke 8588A
See scope document
13-Nitrogen Gas
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 13 of 17 IV. Mechanical Parameter/Equipment Range CMC2, 6, 8 (±) Comments Pressure – Measuring Equipment (0.7 to 50.8) psi (1.4 to 253.8) psi (14.5 to 1102.3) psi (0.2 to 18.7) psi (1.7 to 75.6) psi (1 to 742.1) psi (100 to 3000) psi (1.2 to 55.1) psi (3.6 to 275.6) psi (14.5 to 1102.3) psi (0.2 to 18.7) psi (1.7 to 75.7) psi (0 to 742.1) psi (0 to 3000) psi (0 to 10 000) psi 0.0016 % + 0.000 095 psi 0.0020 % + 0.000 050 psi 0.0036 % + 0.000 17 psi 0.0018 % + 0.000 004 9 psi 0.0019 % + 0.000 017 psi 0.0023 % + 0.000 17 psi 0.0028 % + 0.0058 psi 0.0015 % + 0.000 099 psi 0.0018 % + 0.000 084 psi 0.0036 % + 0.000 33 psi 0.018 % + 0.000 004 2 psi 0.0019 % + 0.000 017 psi 0.0023 % + 0.000 17 psi 0.011 % + 0.11 psi 0.011 % + 0.37 psi DHI PG-7601 Pressure Gauges – Hydraulic (100 to 10 000) psig (500 to 50 000) psig 0.021 % 0.021 % DHI 5306 S Vacuum – Measuring Equipment, Nitrogen Gas Up to 1 Torr Up to 10 Torr Up to 100 Torr 0.087 % 0.087 % 0.087 % MKS 390HA- 00010SP05 Force – Measuring Equipment Tension Compression (5 to 500) lbf (97 to 2000) lbf (200 to 10 000) lbf (5 to 500) lbf (97 to 2000) lbf (200 to 10 000) lbf (2180 to 50 000) lbf 0.012 % + 0.044 lbf 0.006 % + 0.056 lbf 0.0061 % + 0.34 lbf 0.012 % + 0.044 lbf 0.006 % + 0.076 lbf 0.006 % + 0.14 lbf 0.006 % + 1.3 lbf Sensotronics 60001-500 Morehouse 300-2K BLH C3P1 Sensotronics 60001-500 Morehouse 300-2K Morehouse 5K-10K Morehouse 25K-50K
See scope document
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 14 of 17 Parameter/Equipment Range CMC2, 6, 8 (±) Comments Torque – Wrenches & Screwdrivers (2 to 20) lbf∙in (20 to 240) lbf∙in (10 to 100) lbf∙ft (200 to 2000) lbf∙ft 0.14 % 0.29 % 0.12 % 0.31 % AKO torque system Dynamic Acceleration – Measure 5 Hz to 10 kHz; 100 g peak 2.4 % UD 106A Sunstrand 979-0900-001A Agilent 3458A Dynamic Acceleration Linearity – Measure (0.5 to 100) g peak; 200 Hz 0.71 % UD 106A Sunstrand 979-0900-001A Agilent 3458A V. Optical Quantities Parameter/Equipment Range CMC2, 5 (±) Comments Optical Attenuator Nonlinearity – Measure 850 nm 1310 nm 0 dBm -10 dBm -20 dBm -30 dBm -40 dBm -50 dBm 0 dBm -10 dBm -20 dBm -30 dBm -40 dBm -50 dBm 0.017 dB 0.016 dB 0.015 dB 0.019 dB 0.023 dB 0.043 dB 0.0070 dB 0.0068 dB 0.011 dB 0.018 dB 0.018 dB 0.013 dB HP 81551MM laser source w/ Keysight 81624B optical head Agilent 81655A laser source w/ Keysight 81624B optical head
15-Optical Attenuator
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 15 of 17 Parameter/Equipment Range CMC2, 5 (±) Comments Optical Attenuator Nonlinearity – Measure‘ (cont.) 1550 nm 0 dBm -10 dBm -20 dBm -30 dBm -40 dBm -50 dBm 0.0066 dB 0.0065 dB 0.020 dB 0.022 dB 0.021 dB 0.030 dB Agilent 81652A laser source w/ Keysight 81624B optical head Optical Absolute Power – Measure -20 dBm @ 850 nm -20 dBm @ 1310 nm -20 dBm @ 1550 nm 0.064 dB 0.052 dB 0.054 dB HP 81551MM laser source w/ HP 8158B optical attenuator w/ Keysight 81624B optical head Agilent 81655A laser source w/ Agilent 8156A optical attenuator w/ Keysight 81624B optical head Agilent 81652A laser source w/ Agilent 8156A optical attenuator w/ Keysight 81624B optical head Optical Absolute Power – Measure -10 dBm @ 850 nm -10 dBm @ 1310 nm -10 dBm @ 1550 nm 0.069 dB 0.049 dB 0.049 dB HP 81551MM laser source w/ HP 8158B optical attenuator w/ Keysight 81624B optical head Agilent 81655A laser source w/ Agilent 8156A optical attenuator w/ Keysight 81624B optical head Agilent 81652A laser source w/ Agilent 8156A optical attenuator w/ Keysight 81624B optical head
-
16-Temperature – Measuring Equipment; Relative Humidity – Measuring Equipment; Frequency – Reference Signal; Frequency – Measuring Equipment; Frequency – Measure
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 16 of 17 VI. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Temperature – Measuring Equipment (-196 to -38) °C (-38 to 0) °C (0 to 419.5) °C (419.5 to 660) °C 0.0058 °C 0.0056 °C 0.0067 °C 0.017 °C ISOTECH microK 250 L&N 8167-25B Hart 9122 LN2 Liquid Bath Dry Well Relative Humidity – Measuring Equipment (10 to 65) % RH (65 to 95) % RH 0.53 % RH 0.58 % RH Thunder Scientific 2500 Thunder Scientific 2500 VII. Time & Frequency Parameter/Equipment Frequency CMC2, 8 (±) Comments Frequency – Reference 10 MHz Reference Signal 3.6 x 10-11 Hz/Hz Fluke 910R Parameter/Equipment Frequency CMC2, 8 (±) Comments Frequency – Measuring Equipment DC to 20 MHz 20 MHz to 20 GHz 13 x 10-10 Hz/Hz + 50 µHz 5.5 x 10-5 Hz/Hz Fluke 910R HP 3325B HP 8340A Frequency – Measure DC to 3 GHz 1.3 x 10-6 /Hz + 50 µHz Fluke 910R Agilent 53131A ____________________________________________ 1 This laboratory offers commercial calibration service and field calibration service.
See scope document
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.15) Revised 07/22/2026 Page 17 of 17 2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. Calibration and Measurement Capabilities represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 Based on using the standard at the temperature the Fluke 5522A was calibrated (tcal ± 5 °C) and assuming the instrument is zeroed at least every seven days or when the ambient temperature changes more than 5 °C. For resistance, a zero calibration is performed at least every 12 hours within ± 1 °C of use. 5 The measurands stated are generated using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. 6 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches; R is the resolution of the unit under test; D is the numerical value of the nominal diagonal length of the surface plate in inches; % is defined as the percent of reading, unless otherwise noted. 7 This scope meets A2LA’s P112 Flexible Scope Policy. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 Ø is Diameter in inches
18ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

144 Research Drive, Suite A, Hampton, VA, 23666, US

37.02644, -76.34428

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.