United States

RSA Industries Inc dba American Gage

1131 Richfield Rd, 92870, Placentia, CA, United States

Visit website
A2LA 4296.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
26
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 26 scope lines.

A2LA certificate 4296.01 · 26 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 2 of 25 Parameter/Equipment Range CMC2, 4, 9 (±) Comments Indicators3 Up to 1 in Up to 2 in Up to 10 in 46 µin 92 µin 590 µin Gage blocks Indicator – Amplifier Up to 0.002 in 3 µin Gage blocks Gage Block Comparators3 Up to 0.0003 in Up to 0.001 in 2 µin 2.5 µin Gage blocks Master Comparators – Meter3 Up to 0.0002 in Up to 0.0004 in Up to 0.002 in Up to 0.004 in Up to 0.02 in 3.6 µin 6.2 µin 29 µin 58 µin 290 µin Gage blocks Height Master3 Parallelism of Steps Micrometer Linearity Step Height Up to 0.001 in Up to 1 in Up to 4 in (4 to 24) in 15 µin (17 + 6.9L) µin (19 + 6.9L) µin (25 + 6.9L) µin Gage blocks & amplifier Gage blocks Length Parallelism Flatness (0.01 to 4) in (5 to 20) in (0.01 to 20) in (0.01 to 20) in (3.3 + 1.8L) µin (2.4 + 2.7L) µin 1.2 µin 3.2 µin Gage blocks & comparator Optical flat Length Standards – Measure5 Up to 72 in (120 + 6.6L) µin Using gage blocks & amplifier Ring Gages (0.04 to 1) in (> 1 to 12) in 10 µin (7 + 3D) µin Master comparator, gage blocks
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 3 of 25 Parameter/Equipment Range CMC2, 4, 9 (±) Comments 2D Length – Measure5 Light Probe High – Precision Wide – Field Up to 3.54 in Up to 4.92 in Up to 7.87 in (320 + 7L) µin (79 + 6.9L) µin (200 + 6.9L) µin Using Keyence IM-7020 vision system Dimensional Measuring Systems 3 0.02 in 0.1 in 0.1 in 0.2 in 0.8 in 13 µin + 0.58R 17 µin + 0.58R 6.4 µin + 0.58R 7 µin + 0.58R 23 µin + 0.58R Master gages Steel pin gage Ceramic pin gage Ceramic gage block Ceramic gage block Ceramic ring gage Thread Plug Gages (60°) – Pitch Diameter Major Diameter (0.06 to 1) in (> 1 to 6) in (0.06 to 1) in (> 1 to 6) in (58 + 11D) µin (60 + 9D) µin 20 µin (18 + 2D) µin P&W Supermicrometer TM, thread wires, gage blocks P&W SupermicrometerTM3 – Spindle Meter Force 1 in 0.001 in (2 to 16) ozf (16 to 40) ozf 15 µin 10 µin 0.56 ozf 2.9 ozf Gage blocks Force gage Plug Gages Up to 1 in (> 1 to 12) in 20 µin (18 + 2D) µin P&W Supermicrometer TM, gage blocks, universal comparator Adjustable Thread Ring Gages (60°) – Pitch Diameter 3 Up to 6 in (W) Set Plug Tolerance Comparison to thread set plugs; tolerance of set plug is the stated CMC
to 3.54 in
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 4 of 25 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 7 (±) Comments DC Voltage3 – Generate (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 7.5 µV/V + 0.4 µV 5 µV/V + 0.7 µV 3.5 µV/V + 2.9 µV 3.5 µV/V + 4.3 µV 5 µV/V + 43 µV 6.5 µV/V + 440 µV Fluke 5720A DC Voltage3 – Generate (0 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1000) V 16 µV/V + 0.78 µV 9 µV/V + 1.6 µV 9 µV/V + 16 µV 14 µV/V + 120 µV 14 µV/V + 1.4 mV Fluke 5522A DC Voltage3 – Measure (0 to 200) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1050) V (0 to 10) kV 4.5 µV/V + 0.1 µV 3 µV/V + 0.42 µV 3 µV/V + 4.7 µV 4.5 µV/V + 43 µV 4.5 µV/V + 560 µV 0.36 % + 0.038 V Fluke 8508A Vitrek 4700 DC Current3 – Generate (0 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A 40 µA/A + 6 nA 35 µA/A + 7 nA 35 µA/A + 40 nA 45 µA/A + 0.7 µA 80 µA/A + 12 µA 360 µA/A + 480 µA Fluke 5720A/5725A DC Current3 – Generate (0 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (20 to 100) A (100 to 300) A 120 µA/A + 0.016 µA 78 µA/A + 0.039 µA 78 µA/A + 0.19 µA 78 µA/A + 1.9 µA 160 µA/A + 31 µA 300 µA/A + 31 µA 390 µA/A + 390 µA 1 mA/A + 580 µA 0.058 % + 0.58R 0.12 % + 0.58R Fluke 5522A Guildline 9711, Fluke 8508A, & power supplies
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 5 of 25 Parameter/Equipment Range CMC2, 4, 7 (±) Comments DC Current3 – Measure (0 to 200) µA (0.2 to 2) mA (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A (20 to 100) A (100 to 300) A 12 µA/A + 0.41 nA 12 µA/A + 4 nA 13 µA/A + 40 nA 36 µA/A + 0.84 µA 170 µA/A + 16 µA 380 µA/A + 400 µA 0.058 % + 0.58R 0.12 % + 0.58R Fluke 8508A Guildline 9711, Fluke 8508A Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate Up to 22 mV (22 to 220) mV (0.22 to 2.2) V (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 240 µV/V + 4 µV 90 µV/V + 4 µV 80 µV/V + 4 µV 200 µV/V + 5 µV 500 µV/V + 5 µV 1.1 mV/V + 10 µV 1.4 mV/V + 20 µV 2.7 mV/V + 20 µV 240 µV/V + 12 µV 90 µV/V + 7 µV 80 µV/V + 7 µV 200 µV/V + 7 µV 460 µV/V + 17 µV 900 µV/V + 20 µV 1.4 mV/V + 25 µV 2.7 mV/V + 45 µV 240 µV/V + 41 µV 90 µV/V + 16 µV 45 µV/V + 9 µV 75 µV/V + 10 µV 110 µV/V + 30 µV 420 µV/V + 80 µV 0.1 mV/V + 200 µV 1.7 mV/V + 310 µV Fluke 5720A/5725A
to 20 A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 6 of 25 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate (cont) (2.2 to 22) V (22 to 220) V (220 to 250) V (220 to 750) V (220 to 1100) V (1 to 33) mV (33 to 330) mV (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (15 to 50) Hz (0.05 to 1) kHz (30 to 50) kHz (50 to 100) kHz (0.04 to 1) kHz (1 to 20) kHz (20 to 30) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 240 µV/V + 400 µV 90 µV/V + 150 µV 45 µV/V + 150 µV 75 µV/V + 100 µV 100 µV/V + 200 µV 270 µV/V + 600 µV 1 mV/V + 2 mV 1.5 mV/V + 3.2 mV 240 µV/V + 4 mV 90 µV/V + 2 mV 52 µV/V + 0.7 mV 80 µV/V + 1 mV 150 µV/V + 2.5 mV 900 µV/V + 16 mV 4.4 mV/V + 40 mV 8 mV/V + 80 mV 300 µV/V + 16 mV 70 µV/V + 4 mV 600 µV/V + 12 mV 2.3 mV/V + 45 mV 90 µV/V + 5 mV 170 µV/V + 7.2 mV 600 µV/V + 11 mV 620 µV/V + 4.8 µV 120 µV/V + 4.7 µV 160 µV/V + 4.7 µV 0.78 mV/V + 4.7 µV 2.7 mV/V + 9.3 µV 6.2 mV/V + 39 µV 230 µV/V + 6.2 µV 110 µV/V + 6.2 µV 120 µV/V + 6.2 µV 270 µV/V + 6.3 µV 620 µV/V + 25 µV 1.6 mV/V + 54 µV Fluke 5720A/5725A Max voltage is subject to 2.2 x 10e7 V-Hz
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 7 of 25 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate (cont) (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.045 to 1) kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz 230 µV/V + 39 µV 120 µV/V + 47 µV 150 µV/V + 47 µV 230 µV/V + 40 µV 540 µV/V + 97 µV 1.9 mV/V + 470 µV 230 µV/V + 510 µV 120 µV/V + 470 µV 190 µV/V + 470 µV 270 µV/V + 470 µV 700 µV/V + 1.2 mV 150 µV/V + 4.8 mV 160 µV/V + 4.7 mV 190 µV/V + 4.7 mV 230 µV/V + 4.7 mV 1.6 mV/V + 39 mV 230 µV/V + 9.5 mV 190 µV/V + 8.2 mV 230 µV/V + 8.8 mV Fluke 5522A AC Voltage3 – Measure Up to 200 mV (0.2 to 2) V (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 160 µV/V + 14 µV 130 µV/V + 4 µV 110 µV/V + 4 µV 110 µV/V + 2 µV 110 µV/V + 4 µV 310 µV/V + 8 µV 710 µV/V + 20 µV 140 µV/V + 120 µV 110 µV/V + 21 µV 85 µV/V + 20 µV 65 µV/V + 20 µV 85 µV/V + 20 µV 210 µV/V + 40 µV 510 µV/V + 200 µV 0.3 % + 2 mV 1 % + 20 mV Fluke 8508A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 8 of 25 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Measure (cont) (2 to 20) V (20 to 200) V (200 to 1050) V (0 to 10) kV (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 10) Hz (10 to 40) Hz (40 to 100) Hz (0.1 to 2) kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 10) Hz (10 to 40) Hz (0.04 to 10) kHz (10 to 30) kHz (30 to 100) kHz (0.1 to 200) Hz (200 to 450) Hz (450 to 600) Hz 140 µV/V + 1.2 mV 110 µV/V + 0.2 mV 85 µV/V + 0.2 mV 65 µV/V + 0.2 mV 85 µV/V + 0.2 mV 210 µV/V + 0.4 mV 510 µV/V + 2 mV 0.3 % + 20 mV 1 % + 200 mV 140 µV/V + 12 mV 110 µV/V + 2 mV 85 µV/V + 2 mV 65 µV/V + 2 mV 85 µV/V + 2 mV 210 µV/V + 4 mV 510 µV/V + 20 mV 0.3 % + 200 mV 1 % + 2 V 140 µV/V + 70 mV 110 µV/V + 20 mV 95 µV/V + 20 mV 210 µV/V + 40 mV 510 µV/V + 200 mV 0.14 % + 0.12 V 0.46 % + 0.12 V 0.87 % + 0.12 V Fluke 8508A Vitrek 4700 AC Current3 – Generate Up to 220 µA (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz 250 µA/A + 17 nA 160 µA/A + 10 nA 120 µA/A + 8 nA 280 µA/A + 12 nA 1.1 mA/A + 65 nA Fluke 5720A/5725A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 9 of 25 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current3 – Generate (cont) (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (0.02 to 1) kHz (1 to 5) kHz (5 to 10) kHz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz 250 µA/A + 42 nA 160 µA/A + 36 nA 120 µA/A + 35 nA 200 µA/A + 110 nA 1.1 mA/A + 650 nA 250 µA/A + 410 nA 160 µA/A + 360 nA 120 µA/A + 350 nA 200 µA/A + 550 nA 1.1 mA/A + 5 µA 250 µA/A + 4.7 µA 160 µA/A + 3.6 µA 120 µA/A + 2.5 µA 200 µA/A + 3.5 µA 1.1 mA/A + 10 µA 260 µA/A + 35 µA 450 µA/A + 80 µA 7 mA/A + 160 µA 460 µA/A + 180 µA 950 µA/A + 390 µA 3.6 mA/A + 750 µA Fluke 5720A/5725A AC Current3 – Generate (29 to 330) µA (0.33 to 3.3) mA (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.16 % + 0.078 µA 0.12 % + 0.078 µA 0.097 % + 0.078 µA 0.23 % + 0.12 µA 0.62 % + 0.16 µA 1.2 % + 0.31 µA 0.16 % + 0.12 µA 0.097 % + 0.12 µA 0.078 % + 0.12 µA 0.16 % + 0.16 µA 0.39 % + 0.23 µA 0.78 % + 0.47 µA Fluke 5522A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 10 of 25 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current3 – Generate (cont) (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz 0.14 % + 1.6 µA 0.07 % + 1.6 µA 0.031 % + 1.6 µA 0.062 % + 1.6 µA 0.16 % + 2.3 µA 0.31 % + 3.1 µA 0.14 % + 16 µA 0.07 % + 16 µA 0.031 % + 16 µA 0.078 % + 39 µA 0.16 % + 78 µA 0.31 % + 160 µA 0.14 % + 78 µA 0.047 % + 78 µA 0.47 % + 0.78 mA 1.9 % + 3.9 mA 0.047 % + 1.6 mA 0.078 % + 1.6 mA 2.3 % + 1.6 mA 0.093 % + 3.9 mA 0.12 % + 3.9 mA 2.3 % + 3.9 mA Fluke 5522A AC Current3 – Measure Up to 200 µA (0.2 to 2) mA (1 to 10) Hz (0.01 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (0.01 to 10) kHz (10 to 30) kHz (30 to 100) kHz 480 µA/A + 0.021 µA 480 µA/A + 0.02 µA 650 µA/A + 0.02 µA 0.4 % + 0.02 µA 290 µA/A + 0.2 µA 280 µA/A + 0.2 µA 650 µA/A + 0.2 µA 0.4 % + 0.2 µA Fluke 8508A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 11 of 25 Parameter/Range Frequency CMC2, 4, 7 (±) Comments AC Current3 – Measure (cont) (2 to 20) mA (20 to 200) mA (0.2 to 2) A (2 to 20) A (20 to 100) A (1 to 10) Hz (0.01 to 10) kHz (10 to 30) kHz (30 to 100) kHz (1 to 10) Hz (0.01 to 10) kHz (10 to 30) kHz (0.01 to 2) kHz (2 to 10) kHz (10 to 30) kHz (0.01 to 2) kHz (2 to 10) kHz (0.1 to 1000) Hz 290 µA/A + 2 µA 280 µA/A + 2 µA 650 µA/A + 2 µA 0.4 % + 2 µA 290 µA/A + 20 µA 250 µA/A + 20 µA 600 µA/A + 20 µA 600 µA/A + 200 µA 710 µA/A + 200 µA 0.3 % + 200 µA 800 µA/A + 2 mA 0.25 % + 2 mA 0.13 A + 0.58R Fluke 8508A Valhalla 2575A & 8508A Parameter/Equipment Range CMC2, 7 (±) Comments Resistance3 – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω (0.2 to 2) kΩ (2 to 20) kΩ (20 to 200) kΩ (0.2 to 2) MΩ (2 to 20) MΩ (20 to 200) MΩ (0.2 to 2) GΩ (2 to 20) GΩ 15 µΩ/Ω + 4 µΩ 9 µΩ/Ω + 14 µΩ 7.5 µΩ/Ω + 51 µΩ 7.5 µΩ/Ω + 510 µΩ 7.5 µΩ/Ω + 5 mΩ 7.5 µΩ/Ω + 52 mΩ 8.5 µΩ/Ω + 530 mΩ 15 µΩ/Ω + 10 Ω 60 µΩ/Ω + 100 Ω 530 µΩ/Ω + 1 kΩ 530 µΩ/Ω + 10 kΩ Fluke 8508A Resistance3 – Generate (100 to 1000) MΩ (1 to 10) GΩ (10 to 100) GΩ (100 to 1000) GΩ (1 to 11.111) TΩ 220 µΩ/Ω 680 µΩ/Ω 3.7 mΩ/Ω 4 mΩ/Ω 15 mΩ/Ω HRRS-10kV
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 12 of 25 Parameter/Equipment Range CMC2, 7 (±) Comments Resistance3 – Generate (cont) Fixed Points (1, 1.9) Ω (10, 19) Ω (100, 190) Ω (1, 1.9) kΩ (10, 19) kΩ (100, 190) kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 95 µΩ/Ω + 0.2 µΩ 23 µΩ/Ω + 1.5 µΩ 10 µΩ/Ω + 11 µΩ 9 µΩ/Ω + 120 µΩ 9 µΩ/Ω + 1.5 mΩ 11 µΩ/Ω + 15 mΩ 20 µΩ/Ω + 180 mΩ 21 µΩ/Ω + 140 mΩ 40 µΩ/Ω + 580 mΩ 47 µΩ/Ω + 1.1 Ω 100 µΩ/Ω + 15 Ω Fluke 5720A Resistance3 – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 31 µΩ/Ω + 0.78 mΩ 23 µΩ/Ω + 1.2 mΩ 22 µΩ/Ω + 1.1 mΩ 22 µΩ/Ω + 1.6 mΩ 22 µΩ/Ω + 2.2 mΩ 22 µΩ/Ω + 16 mΩ 22 µΩ/Ω + 16 mΩ 22 µΩ/Ω + 160 mΩ 22 µΩ/Ω + 160 mΩ 25 µΩ/Ω + 1.6 Ω 25 µΩ/Ω + 1.7 Ω 47 µΩ/Ω + 24 Ω 100 µΩ/Ω + 39 Ω 200 µΩ/Ω + 2 kΩ 390 µΩ/Ω + 2 kΩ 2.3 mΩ/Ω + 78 kΩ 12 mΩ/Ω + 390 kΩ Fluke 5522A Parameter/Range Frequency CMC2, 7 (±) Comments Capacitance3 – Generate (0.19 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz 0.39 % + 0.0081 nF 0.39 % + 0.0078 nF 0.19 % + 0.0078 nF 0.19 % + 0.078 nF 0.19 % + 0.23 nF 0.19 % + 0.83 nF 0.19 % + 2.3 nF Fluke 5522A *Excludes 0.7 mF
to 1100 MΩ
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 13 of 25 Parameter/Range Frequency CMC2, 7 (±) Comments Capacitance3 – Generate (cont) (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.19 % + 7.8 nF 0.31 % + 23 nF 0.35 % + 78 nF 0.35 % + 230 nF 0.35 % + 0.78 µF 0.35 % + 2.3 µF 0.35 % + 12 µF 0.58 % + 23 µF 0.85 % + 82 µF Fluke 5522A *Excludes 0.7 mF Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouple Indicators & Indicating Systems 3 – Type E Type J Type K Type T (-270 to -245) °C (-245 to -195) °C (-195 to -155) °C (-155 to -90) °C (-90 to 15) °C (15 to 890) °C (890 to 1000) °C (-210 to -180) °C (-180 to -120) °C (-120 to -50) °C (-50 to 990) °C (990 to 1200) °C (-270 to -255) °C (-255 to -195) °C (-195 to -115) °C (-115 to -55) °C (-55 to 1000) °C (-270 to -255) °C (-255 to -240) °C (-240 to -210) °C (-210 to -150) °C (-150 to -40) °C (-40 to 100) °C (100 to 400) °C 1.4 °C 0.21 °C 0.12 °C 0.097 °C 0.083 °C 0.071 °C 0.082 °C 0.14 °C 0.12 °C 0.094 °C 0.083 °C 0.082 °C 2.5 °C 0.81 °C 0.14 °C 0.11 °C 0.087 °C 2.1 °C 0.57 °C 0.35 °C 0.21 °C 0.14 °C 0.094 °C 0.083 °C Ectron Corporation 1140A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 14 of 25 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of RTD Indicators3 Pt 385, 100 Ω: ( -200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C Pt 385, 200 Ω: ( -200 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C Pt 385, 500 Ω: (-200 to -80) °C (-80 to 100) °C (100 to 260) °C (260 to 400) °C (400 to 600) °C (600 to 630) °C Pt 385, 1000 Ω: (-200 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 600) °C (600 to 630) °C Pt 3916, 100 Ω : (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C Pt 3926, 100 Ω: (-200 to -0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C 0.051 °C 0.071 °C 0.092 °C 0.10 °C 0.12 °C 0.23 °C 0.041 °C 0.051 °C 0.12 °C 0.13 °C 0.14 °C 0.16 °C 0.041 °C 0.051 °C 0.061 °C 0.082 °C 0.092 °C 0.11 °C 0.031 °C 0.041 °C 0.051 °C 0.061 °C 0.071 °C 0.23 °C 0.26 °C 0.041 °C 0.051 °C 0.061 °C 0.071 °C 0.082 °C 0.092 °C 0.10 °C 0.23 °C 0.051 °C 0.071 °C 0.092 °C 0.10 °C 0.12 °C Fluke 5522A
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 15 of 25 Parameter Range CMC2, 4, 6, 7 (±) Comments Electrical Simulation of RTD Indicators3 (cont) PtNi 385, 120 Ω: (-80 to 100) °C (100 to 260) °C Cu 427, 10 Ω: (-100 to 260) °C 0.082 °C 0.14 °C 0.31 °C Fluke 5522A Waveform – Measure3 Voltage Frequency Rise Time (0 to 100) V Up to 500 MHz Up to 500 MHz 0.12 % + 0.82R 0.24 % + 0.82R 0.81 ns + 0.82R Tektronix TDS3054B Oscilloscopes3 – DC Voltage: 50 Ω 1 MΩ Square Wave Voltage: 10 Hz to 10 kHz (50 Ω) 10 Hz to 1 kHz (1 MΩ) (1 to 10) kHz (1 MΩ) Square Wave Frequency Rise Time – Generate: 1 kHz to 2 MHz (2 to 10) MHz Time Marker, 50 Ω Pulse Width Square, Sine, & Triangle Waveforms: 10 Hz to 100 kHz: 1 MΩ 50 Ω (0 to 6) V (0 to 130) V 1 mVp-p to 6 Vp-p 1 mVp-p to 130 Vp- p 1 mVp-p to 130 Vp- p 10 Hz to 10 kHz ≤ 300 ps < 350 ps 5 s to 20 ms 20 ms to 1 ns (4 to 500) ns 20 ms to 200 ns 1.8 mV to 55 Vp-p 1.8 mV to 2.5 Vp-p 0.19 % + 31 µV 0.039 % + 40 µV 0.19 % + 69 µV 0.078 % + 130 µV 0.19 % + 130 µV 1.9 µHz/Hz + 0.58R 78 ps 78 ps (25 + 1000t) µs/s 1.9 µs/s + 0.0031 ns 3.9 % + 2 ns 1.9 µs/s + 0.18 ns 2.3 % + 150 µV 2.3 % + 78 µV Fluke 5522A t = time in seconds
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 16 of 25 Parameter Range CMC2, 6 (±) Comments Oscilloscopes3 – (cont) Level Sine Wave: 5 mV to 5.5 V 4 mV to 3.5 V Flatness Relative to 50 kHz Frequency 50 kHz to 10 MHz (10 to 100) MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 kHz to 1100 MHz 1.6 % + 240 µV 2.7 % + 240 µV 3.1 % + 240 µV 4.7 % + 240 µV 5.4 % + 240 µV 1.2 % + 97 µV 1.6 % + 97 µV 3.1 % + 97 µV 3.9 % + 97 µV 1.9 µHz/Hz + 550 µHz Fluke 5522A III. RF/Microwave Parameter/Range Frequency CMC2, 7 (±) Comments RF Power3 – Measure (-50 to 30) dBm (-35 to 20) dBm (-35 to 20) dBm 9 kHz to 13 GHz (13 to 18) GHz 10 MHz to 18 GHz (18 to 26.5) GHz (26.5 to 33) GHz 50 MHz to 18 GHz (18 to 26.5) GHz (26.5 to 33) GHz (33 to 50) GHz 0.080dBm 0.091 dBm 0.086 dBm 0.12 dBm 0.14 dBm 0.087 dBm 0.11 dBm 0.13 dBm 0.17 dBm E4419B & E9304A E4419B & N8485A 033 E4419B & N8487A RF Power3 – Generate ( -110 to -10) dBm (-10 to 10) dBm 50 MHz to 20 GHz (20 to 26.5) GHz (20 to <40) GHz (40 to 50) GHz 50 MHz to 18 GHz (18 to 26.5) GHz (26.5 to 50) GHz 0.38 dBm 0.45 dBm 0.50 dBm 0.82 dBm 0.11 dBm 0.14 dBm 0.20 dBm 83650B signal generator
17--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 17 of 25 Parameter/Equipment Range CMC2, 7 (±) Comments Tuned RF – Measure3 100 kHz to 26.5 GHz 100 kHz to 3.05 GHz (3.05 to 6.6) GHz (6.6 to 13.2) GHz (13.2 to 19.2) GHz (19.2 to 26.5) GHz (+10 to 0) dBm (0 to -10) dBm (-10 to -20) dBm (-20 to -30) dBm (-30 to -40) dBm (-40 to -50) dBm (-50 to -60) dBm (-60 to -70) dBm (-70 to -80) dBm (-80 to -90) dBm (-90 to -100) dBm (-100 to -110) dBm (-110 to -120) dBm (-120 to -130) dBm (-70 to -80) dBm (-80 to -90) dBm (-90 to -100) dBm (-100 to -110) dBm (-110 to -120) dBm (-120 to -126) dBm (-70 to -80) dBm (-80 to -90) dBm (-90 to -100) dBm (-100 to -110) dBm (-110 to -117) dBm (-70 to -80) dBm (-80 to -90) dBm (-90 to -100) dBm (-100 to -10) dBm (-70 to -80) dBm (-80 to -90) dBm (-90 to -100) dBm (-100 to -102) dBm 0.024 dB 0.018 dB 0.024 dB 0.029 dB 0.035 dB 0.041 dB 0.053 dB 0.069 dB 0.074 dB 0.10 dB 0.11 dB 0.24 dB 0.66 dB 1.4 dB 0.074 dB 0.10 dB 0.12 dB 0.37 dB 0.91 dB 1.4 dB 0.074 dB 0.11 dB 0.32 dB 0.83 dB 1.4 dB 0.075 dB 0.25 dB 0.70 dB 1.4 dB 0.17 dB 0.53 dB 1.2 dB 1.4 dB E4440 Opt. 233
100000 to 26500000000 Hz
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 18 of 25 Parameter/Equipment Frequency CMC2, 6, 7 (±) Comments Flatness3 Reference 100 kHz Reference 10 MHz Reference 50 MHz Reference 1 GHz Reference 10 MHz Reference 50 MHz Reference 1 GHz Reference 50 MHz Reference 1 GHz 9 kHz to 12.4 GHz (12.4 to 18) GHz 9 kHz to 12.4 GHz (12.4 to 18) GHz 9 kHz to 12.4 GHz (12.4 to 18) GHz 9 kHz to 12.4 GHz (12.4 to 18 GHz 10 MHz to 18 GHz (18 to 26.5) GHz (26.5 to 33) GHz 10 MHz to 18 GHz (18 to 26.5) GHz (26.5 to 33) GHz 10 MHz to 18 GHz (18 to 26.5) GHz (26.5 to 33) GHz 10 MHz to 18 GHz (18 to 33) GHz (33 to 50) GHz 10 MHz to 18 GHz (18 to 33) GHz (33 to 50) GHz 0.031 dB 0.046 dB 0.031 dB 0.040 dB 0.030 dB 0.046 dB 0.030 dB 0.040 dB 0.068 dB 0.079 dB 0.097 dB 0.062 dB 0.079 dB 0.097 dB 0.062 dB 0.081 dB 0.099 dB 0.057 dB 0.082 dB 0.12 dB 0.057 dB 0.083 dB 0.13 dB E4419B & E9304A E4419B & N8485A- 33 E4419B & N8487A Power Sensor Calibration Factors 9 kHz to 8 GHz (8 to 14) GHz (14 to 17) GHz (17 to 18) GHz (1 to 8) GHz (9 to 13) GHz 10 MHz to 18 GHz (18 to 24) GHz (24 to 26.5) GHz (26.5 to 33) GHz 1.1 % 1.2 % 1.3 % 1.5 % 1.4 % 1.6 % 1.7 % 2.1 % 2.2 % 2.6 % E4419B & E9304A E4419B & N8485A- 33
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 19 of 25 Parameter/Equipment Range CMC2, 6, 7 (±) Comments Power Sensor Calibration Factors (cont) 100 MHz to 2 GHz (2 to 12.4) GHz 50 MHz to 18 GHz (18 to 26.5) GHz (26.5 to 33) GHz (33 to 38) GHz (38 to 50) GHz 1.4 % 1.5 % 1.7 % 1.9 % 2.0 % 2.6 % 3.0 % E4419B & N8487A Amplitude Modulation3 – Measure CW: 100 kHz to 10 MHz 10 MHz to 3 GHz (3 to 26.5) GHz 50 Hz to 10 kHz (5 to 99) % Depth 50 Hz to 100 kHz (5 to 20) % Depth (20 to 99) % Depth 50 Hz to 100 kHz (5 to 20) % Depth (20 to 99) % Depth 0.68% IV + 0.25 % AM 1.7 % IV + 0.39 % AM 0.41 % IV + 0.39 % AM 4.1 % IV + 0.32 % AM 1.6 % IV + 0.27 % AM E4440A Opt. 23A Frequency Modulation3 – Measure Rate: 20 Hz to 10 kHz Deviation: 200 Hz to 40 kHz Rate: 50 Hz to 200 kHz Deviation: 250 Hz to 400 kHz (0.25 to 10) MHz >0.2 ß >1.2 ß (0.01 to 6.6) GHz >0.2 ß >0.45 ß (6.6 to 13.2) GHz >0.2 ß >8 ß (13.2 to 26.5) GHz >0.2 ß >16 ß 1.6 % IV + 5.7 Hz 1.0 % IV + 6.6 Hz 1.7 % IV + 5.6 Hz 1.2 % IV + 6.4 Hz 3.0 % IV + 12 Hz 1.2 % IV + 14 Hz 4.5 % IV + 24 Hz 1.2 % IV + 12 Hz E4440A Opt. 23A ß = Deviation / Rate
20--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 20 of 25 Parameter/Range Frequency CMC2, 4, 7 (±) Comments Phase Modulation3 – Measure 100 kHz to 6.6 Ghz (6.6 to 13.2) GHz (13.2 to 26.5) GHz >0.7 rad >0.3 rad >2.0 rad >0.6 rad >4.0 rad >1.2 rad 1.2 % + 0.019 rad 2.0 % + 0.022 rad 1.2 % + 0.011 rad 3.0 % + 0.015 rad 1.2 % + 0.006 rad 3.3 % + 0.011 rad E4440A Opt. 23A Modulation Distortion3 – Measure (-80 to 0) dB 200 Hz to 300 kHz 1.3 dB E440A Opt 23A Phase Noise3 – Measure 1 MHz to 26.5 GHz Offset: 10 Hz 100 Hz 1 kHz 10 kHz 100 kHz 1 MHz 10 MHz 100 MHz 1.5 dBc/Hz 1.0 dBc/Hz 0.69 dBc/Hz 0.73 dBc/Hz 0.77 dBc/Hz 0.66 dBc/Hz 0.76 dBc/Hz 0.92 dBc/Hz E4440A Opt 226 Audio Distortion3 – Measure (-80 to 0) dB (-65 to 0) dB 20 Hz to 20 kHz 20 kHz to 100 kHz 1.2 dB 2.4 dB 8903B
-80 to 0 dB
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 21 of 25 IV. Mechanical Parameter/Equipment Range CMC2, 4, 6, 9 (±) Comments Torque – Measure Wrenches & Drivers3 (1 to 2) lbf·in (2 to 10) lbf·in (5 to 50) lbf·in (40 to 400) lbf·in (100 to 1000) lbf·in (50 to 250) lbf∙ft (60 to 600) lbf∙ft 1.2 % + 0.58R 0.59 % + 0.58R 0.76 % + 0.58R 0.42 % + 0.58R 0.37 % + 0.58R 0.52 % + 0.58R 0.43 % + 0.58R Torque testers Force3 – Measure & Measuring Equipment Tension/Compression (Up to 10000) lbf 0.009% + 0.4 lbf Morehouse HADI Morehouse precision load cells Pressure3 – Measure & Measuring Equipment Hydraulic Pneumatic (0 to 3000) psia (3000 to 6000) psia (6000 to 10 000) psia (0 to 125) psig (125 to 2500) psig (0 to 1) psig (1 to 20) psig (0 to 50) psia (0 to 1) inH 2O (1 to 30) inH2O (0 to 12.5) psig (12.5 to 250) psig 0.5 psia + 0.58R 1 psia + 0.58R 1.7 psia + 0.58R 0.0081 % + 0.0063 psi 0.0095 % + 0.0044 psi 0.0001 psi + 0.58R 0.009 % + 0.58R 0.008 psia + 0.58R 0.000 68 inH 2O + 0.58R 0.011 % + 0.58R 0.0017 psi + 0.58R 0.0093 % + 0.58R Ruska 7615 Fluke 7250xi Fluke 7250xi 3 Ruska 6220 Fluke 7250LP 3 Fluke 7250xi 3 Vacuum3 – Measure & Measuring Equipment (-14.5 to 0) psi 0.0016 psi + 0.58R Fluke 7250xi
22-Scales & Balances
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 22 of 25 Parameter Range CMC2, 4, 9 (±) Comments Scales & Balances3 2 mg (5 to 500) mg (1 to 2) g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1 kg 2 kg 5 kg 10 kg 20 kg 25 kg 30 kg 75 kg 0.0029 mg + 0.58R 0.012 mg + 0.58R 0.040 mg + 0.58R 0.0072 mg + 0.58R 0.013 mg + 0.58R 0.017 mg + 0.58R 0.019 mg + 0.58R 0.04 mg + 0.58R 0.07 mg + 0.58R 2.2 mg + 0.58R 3.1 mg + 0.58R 5.9 mg + 0.58R 14 mg + 0.58R 29 mg + 0.58R 110 mg + 0.58R 130 mg + 0.58R 130 mg + 0.58R 170 mg + 0.58R Troemner platinum class, & Class 1 weights Mass – Measure (1, 2, 3, 10, 20, 30, 100, 200, 300, 500) mg (1, 2, 3, 5) g 10 g 20 g 30g 50 g 100 g 200 g 300 g 500 g 1 kg 2 kg 5 kg 10 kg 20 kg 25 kg 1 lb (453.59 g) 5 lb (2.27 kg) 10 lb (4.54 kg) 20 lb (9.07 kg) 25 lb (11.34 kg) 50 lb (22.68 kg) 0.002 mg 0.006 mg 0.007 mg 0.01 mg 0.03 mg 0.04 mg 0.07 mg 0.04 mg 0.1 mg 0.1 mg 0.3 mg 0.4 mg 3 mg 4 mg 5 mg 9 mg 0.4 mg 1.6 mg 3 mg 4 mg 4 mg 10 mg Troemner ultra class, Class 0, Class 1 weights & balances.
See scope document
23ISO-8655-6; ISO-8655-8-See scope document
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 24 of 25 Parameter Range CMC2, 4, 9 (±) Comments Humidity – Measuring Equipment (10 to 95) % RH 0.52 % RH + 0.58R Thunder Scientific 2500 Temperature Sensors – Measuring Equipment & Measure (0 to 70) °C 0.062 °C + 0.58R Thunder Scientific 2500 Temperature3 – Measure (-196 to 0) °C (0 to 420) °C (420 to 660) °C 0.0042 °C + 0.58R 0.0045 °C + 0.58R 0.0048 °C + 0.58R Fluke 1594A & 5699 Temperature – Measuring Equipment -196 °C (-60 to 0) °C (0 to 420) °C (420 to 550) °C 0.0042 °C + 0.58R 0.0042 °C + 0.58R 0.0045 °C + 0.58R 0.0048 °C + 0.58R LN2 Fluke 1594A, 5699, & baths Infrared3 – Thermometers & Cameras (-15 to 0) °C (0 to 35) °C (35 to 100) °C (100 to 200) °C (200 to 350) °C (350 to 500) °C 0.55 °C + 0.58R 0.51 °C + 0.58R 0.46 °C + 0.58R 0.63 °C + 0.58R 0.95 °C + 0.58R 2.1 °C + 0.58R Fluke 4180 & 4181 Emissivity ε = 0.95, where λ = (8 to 14) µm VII. Time & Frequency Parameter Range CMC2, 4, 9 (±) Comments Frequency – Measuring Equipment 5, 10 MHz Up to 80 MHz 10 MHz to 50 GHz Up to 80 MHz 10 MHz to 50 GHz 6.4 × 10-13 Hz/Hz 1.0 × 10 -11 Hz/Hz + 0.58R 8.6 × 10-12 Hz/Hz + 0.58R 5.9 × 10 -12 Hz/Hz + 0.58R 9.9 × 10-13 Hz/Hz + 0.58R Caesium frequency standard Signal generator & GPS reference Signal generator & caesium reference Frequency3 – Measuring Equipment Up to 50 GHz 3.4 × 10-9 Hz/Hz + 0.58R Signal generator & 53132A Opt 012 time base
25--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4296.01) 03/27/2025 Page 25 of 25 Parameter/Equipment Range CMC2, 4, 9 (±) Comments Stopwatches & Timers3 Up to 24 hours 27 ms + 0.58R 53132A & 33250A Frequency – Measure Up to 46 GHz Up to 46 GHz 8.3 × 10-12 Hz/Hz + 0.58R 3.6 × 10 -12 Hz/Hz + 0.58R Agilent 58503A & 53132A & E4440A Frequency counter & caesium reference Frequency3 – Measure Up to 46 GHz 3.1 × 10-9 Hz/Hz + 0.58R Agilent 53132A & E4440A _____________________________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in micro- inches. R is the resolution of the unit under test. D is the numerical value of the nominal diameter of the device measured in micro-inches. 5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 6 In the statement of CMC, percentages are of reading unless otherwise noted. 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percentage or fraction of the reading plus a fixed floor specification. 8 This scope meets A2LA’s P112 Flexible Scope Policy. 9 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
to 46 GHz
26ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; ANSI/NCSL Z540.3-2006; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.