IET Labs, Inc.
1202 VFW Parkway, 02132, West Roxbury, MA, United States
Visit website- Scope lines
- 12
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 12 scope lines.
A2LA certificate 2073.01 · 12 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2073.01) 03/13/2024 Page 2 of 11
Parameter/Equipment
Range
CMC2, 4, 8 (±)
Comments
DC Resistance –
Measure (cont)
(1 to 2) Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
(2 to 20) GΩ
(20 to 200) GΩ
200 GΩ to 1 TΩ
(1 to 2) TΩ
(2 to 20) TΩ
(20 to 200) TΩ
7 µΩ/Ω + 2.4 µΩ
4 µΩ/Ω + 10 µΩ
2.7 µΩ/Ω + 20 µΩ
3.8 µΩ/Ω + 60 µΩ
0.9 µΩ/Ω + 2 mΩ
2.7 µΩ/Ω
+ 10 mΩ
3 µΩ/Ω + 0.6 Ω
6.3 µΩ/Ω + 2 Ω
8.5 µΩ/Ω
0.0026 %
0.03 %
0.032 %
0.35 %
0.5 %
1.5 %
2.5 %
Ratio transfer method
Voltage
characterization method
w/standards
Keithley 6517A w/
faraday cage
DC Resistance –
Generate, Fixed Points
0.1 mΩ
1 mΩ
10 mΩ
100 mΩ
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 TΩ
4 µΩ/Ω
4 µΩ/Ω
4 µΩ/Ω
4 µΩ/Ω
4 µΩ/Ω
4 µΩ/Ω
1 µΩ/Ω
1.7 µΩ/Ω
0.5 µΩ
/Ω
3.7 µΩ/Ω
3.7 µΩ/Ω
6.2 µΩ/Ω
10 µΩ/Ω
100 µΩ/Ω
100 µΩ/Ω
0.020 %
0.025 %
0.10 %
Otto Wolff 15283/61
L&N 4223-B
Guildline 9334A
SRL-0.1
SRL-1
SRL-10
IET (esi) SR-102
Guildline 9334A
IET (esi) SR-104
SRL-100k
SRL-1M
SRL-10M
Guildline 9334A
SRL-1G
SRC-10G
SRL-100G
OhmLabs 112
OhmLabs 113 | to 200 TΩ |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2073.01) 03/13/2024 Page 3 of 11
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
Capacitance – Measure5
10 aF to 11 μF
10 aF to 100 mF
10 aF to 10 F
50 Hz to 1 kHz
12 Hz to 200 kHz
10 Hz to 2 MHz
0.010 % + 30 aF
0.010 % + 16 fF
0.050 % + 30 fF
IET (GenRad) 1620
IET (GenRad) 1689/1693
IET (Quadtech) 7600+
Capacitance – Measure6
1 fF to 1 μF
50 Hz to 20 kHz
5.5 µF/F + 1 aF
Direct measurement
using capacitance bridge
AH 2700A bridge
Dissipation Factor –
Measure
6
1 µ to 10
(unitless)
50 Hz to 20 kHz
0.024 % + 5 µ
(unitless)
Direct measurement
using capacitance bridge
AH 2700A bridge
Capacitance – Generate
1 fF to 11 μF
1 fF to 100 mF
1 fF to 10 F
Fixed Points:
1 pF
10 pF
100 pF
1000 pF
10 nF
100 nF
1 µF
10 µF
100 µF
1 mF
10 mF
100 mF
1 F
50 Hz to 1 kHz
12 Hz to 200 kHz
10 Hz to 2 MHz
1 kHz
100 Hz
0.010 % + 30 aF
0.010 % + 16 fF
0.050 % + 30 fF
84 µF/F
1.3 µF/F
1.1 µF/F
1.4 µF/F
0.012 %
0.014 %
0.013 %
0.015 %
0.043 %
0.23 %
0.38 %
0.34 %
0.41 %
Various standard
capacitors characterized
at time of use
5
IET (Genrad) 1403
IET (GenRad) 1404-C
IET (GenRad) 1404-B
IET (GenRad) 1404-A
IET SC-10 nF
IET SC-100 nF
IET SC-1 µF
IET SC-10 µF
IET S-100 µF
IET (GenRad) 1417
IET (GenRad) 1417
IET (GenRad) 1417
IET (GenRad) 1417 | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2073.01) 03/13/2024 Page 4 of 11
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
Capacitance – Generate
(cont)
Fixed Points
Algorithmic
Derivation @ Freq:
50 pF
100 pF
200 pF
500 pF
1 nF
2 nF
10 nF
20 nF
50 nF
100 nF
1 kHz to 1 MHz
0.017 %
0.021 %
0.014 %
0.012 %
0.013 %
0.016 %
0.057 %
0.12 %
0.028 %
0.56 %
Various standard
capacitors characterized
at time of use
5
GR/IET 1406E
GR/IET 1406D
GR/IET 1406C
GR/IET 1406B
GR/IET 1406A
GR/IET 1407B
GR/IET 1407D
GR/IET 1407E
GR/IET 1407F
GR/IET 1407G
Inductance – Measure5
10 nH to 100 kH
1 pH to 100 H
12 Hz to 100 kHz
10 Hz to 2 MHz
0.01 % + 50 nH
0.05 % + 120 pH
IET (GenRad) 1689/1693
IET (Quadtech) 7600+
Inductance – Measure,
Fixed Points
10 μH
50 μH
100 μH
200 μH
100 Hz
400 Hz
1 kHz
10 kHz
100 kHz
100 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
400 Hz
1 kHz
10 kHz
1.5 %
0.29 %
0.12 %
0.07 %
0.10 %
0.31 %
0.08 %
0.04 %
0.06 %
0.017 %
0.017 %
0.017 %
0.011 %
0.017 %
0.1 %
0.04 %
0.03 %
0.06 %
IET (GenRad) 1482
standard inductors w/
precision LCR meter | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2073.01) 03/13/2024 Page 5 of 11
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
Inductance – Measure,
Fixed Points (cont)
500 μH
1 mH
2 mH
5 mH
10 mH
20 mH
50 mH
100 mH
100 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
400 Hz
1 kHz
10 kHz
100 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
0.06 %
0.03 %
0.02 %
0.06 %
0.012 %
0.012 %
0.012 %
0.011 %
0.017 %
0.04 %
0.03 %
0.02 %
0.06 %
0.03 %
0.02 %
0.02 %
0.06 %
0.013 %
0.013 %
0.013 %
0.011 %
0.015 %
0.03 %
0.02 %
0.02 %
0.07 %
0.015 %
0.015 %
0.015 %
0.014 %
0.023 %
0.012 %
0.012 %
0.012 %
0.011 %
0.021 %
IET (GenRad) 1482
standard inductors
with precision LCR
meter | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2073.01) 03/13/2024 Page 6 of 11
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
Inductance – Measure,
Fixed Points (cont)
200 mH
500 mH
1 H
2 H
5 H
10 H
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
100 Hz
400 Hz
1 kHz
100 Hz
200 Hz
400 Hz
1 kHz
100 Hz
200 Hz
400 Hz
1 kHz
0.015 %
0.015 %
0.015 %
0.014 %
0.051 %
0.015 %
0.015 %
0.015 %
0.014 %
0.051 %
0.011 %
0.011 %
0.011 %
0.011 %
0.03 %
0.03 %
0.03 %
0.03 %
0.03 %
0.03 %
0.04 %
0.012 %
0.012 %
0.012 %
0.011 %
IET (GenRad) 1482
standard inductors w/
precision LCR meter
Inductance – Generate,
Fixed Points
10 µH
50 µH
100 Hz
400 Hz
1 kHz
10 kHz
100 kHz
100 Hz
400 Hz
1 kHz
10 kHz
1.5 %
0.29 %
0.12 %
0.07 %
0.10 %
0.31 %
0.08 %
0.04 %
0.06 %
IET (GenRad) 1482
standard inductors | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2073.01) 03/13/2024 Page 7 of 11
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
Inductance – Generate,
Fixed Points (cont)
100 µH
200 µH
500 µH
1 mH
2 mH
5 mH
10 mH
20 mH
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
400 Hz
1 kHz
10 kHz
100 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
400 Hz
1 kHz
10 kHz
100 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
400 Hz
1 kHz
10 kHz
0.017 %
0.017 %
0.017 %
0.011 %
0.017 %
0.1 %
0.04 %
0.03 %
0.06 %
0.06 %
0.03 %
0.02 %
0.06 %
0.012 %
0.012 %
0.012 %
0.011 %
0.017 %
0.04 %
0.03 %
0.02 %
0.06 %
0.03 %
0.02 %
0.02 %
0.06 %
0.013 %
0.013 %
0.013 %
0.011 %
0.015 %
0.03 %
0.02 %
0.02 %
0.07 %
IET (GenRad) 1482
standard inductors | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2073.01) 03/13/2024 Page 8 of 11
Parameter/Range
Frequency
CMC2, 4, 8 (±)
Comments
Inductance – Generate,
Fixed Points (cont)
50 mH
100 mH
200 mH
500 mH
1 H
2 H
5 H
10 H
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
10 kHz
100 Hz
200 Hz
400 Hz
1 kHz
100 Hz
400 Hz
1 kHz
100 Hz
400 Hz
1 kHz
100 Hz
200 Hz
400 Hz
1 kHz
0.015 %
0.015 %
0.015 %
0.014 %
0.023 %
0.012 %
0.012 %
0.012 %
0.011 %
0.021 %
0.015 %
0.015 %
0.015 %
0.014 %
0.051 %
0.015 %
0.015 %
0.015 %
0.014 %
0.051 %
0.011 %
0.011 %
0.011 %
0.011 %
0.03 %
0.03 %
0.03 %
0.03 %
0.03 %
0.04 %
0.012 %
0.012 %
0.012 %
0.011 %
IET (GenRad) 1482
standard inductors | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2073.01) 03/13/2024 Page 9 of 11
Parameter/Equipment
Range
CMC2, 3, 8 (±)
Comments
DC Voltage – Generate,
Cardinal Points
10 V
17 µV/V
Fluke 732A
DC Voltage – Measure
(0 to 200) mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
4.5 µV/V + 0.1 µV
3 µV/V + 0.4 µV
3 µV/V + 4 µV
4.5 µV/V + 40 µV
4.5 µV/V + 0.5 mV
Fluke 8508A
DC Current – Measure
(0 to 200) µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
12 µA/A + 0.2 nA
12 µA/A + 2 nA
13 µA/A + 20 nA
36 µA/A + 0.4 µA
0.017 % + 8 µA
0.038 % + 20 µA
Fluke 8508A
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Measure
(0 to 200) mV
(0.2 to 2) V
(2 to 20) V
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
0.013 % + 4 µV
0.011 % + 4 µV
0.011 % + 2 µV
0.011 % + 4 µV
0.030 % + 8 µV
0.071 % + 20 µV
0.011 % + 20 µV
85 µV/V + 20 µV
65 µV/V + 20 µV
85 µV/V + 20 µV
0.021 % + 40 µV
0.051 % + 200 µV
0.3 % + 2 mV
1 % + 2 mV
0.011 % + 200 µV
85 µV/V + 200 µV
65 µV/V + 200 µV
85 µV/V + 200 µV
0.021 % + 400 µV
0.051 % + 2 mV
0.3 % + 20 mV
1 % + 20 mV
Fluke 8508A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2073.01) 03/13/2024 Page 10 of 11
Parameter/Range
Frequency
CMC2, 3, 4, 8 (±)
Comments
AC Voltage – Measure
(cont)
(20 to 200) V
(200 to 1050) V
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
0.011 % + 2 mV
85 µV/V + 2 mV
65 µV/V + 2 mV
85 µV/V + 2 mV
0.021 % + 4 mV
0.051 % + 20 mV
0.3 % + 200 mV
1 % + 200 mV
0.011 % + 0.02 V
95 µV/V + 0.02 V
0.021 % + 0.04 V
0.051 % + 0.2 V
Fluke 8508A
AC Current – Measure
(0 to 200) µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
10 Hz to 10 kHz
(10 to 30) kHz
10 Hz to 10 kHz
(10 to 30) kHz
(30 to 100) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.028 % + 0.02 µA
0.065 % + 0.02 µA
0.4 % + 0.02 µA
0.028 % + 0.2 µA
0.065 % + 0.2 µA
0.4 % + 0.2 µA
0.028 % + 2 µA
0.065 % + 2 µA
0.4 % + 2 µA
0.025 % + 20 µA
0.060 % + 20 µA
0.060 % + 200 µA
0.070 % + 200 µA
0.3 % + 200 µA
0.08 % + 2 mA
0.25 % + 2 mA
Fluke 8508A
AC Resistance –
Measure
5
0.01 mΩ to 100 MΩ
0.1 mΩ to 100 MΩ
12 Hz to 200 kHz
10 Hz to 2 MHz
0.02 %
0.05 %
IET (GenRad) 1689/1693
Quadtech 7600 | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2073.01) 03/13/2024 Page 11 of 11
Parameter/Range
Frequency
CMC2, 8 (±)
Comments
AC Resistance –
Generate
Fixed Points:
24.9 Ω
374 Ω
5.97 kΩ
95.317 kΩ
1 kHz
1 kHz
1 kHz
1 kHz
20 µΩ/Ω
20 µΩ/Ω
20 µΩ/Ω
20 µΩ/Ω
IET (GenRad) 1689-9604
Digibridge calibration kit
II. Time & Frequency
Parameter/Equipment
Range
CMC
2, 8 (±)
Comments
Frequency – Measure
0.01 Hz to 125 MHz
20 µHz/Hz
Precision counter
__________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The measurands stated are measured with the Fluke 8508A. This capability is suitable for the calibration
of the parameters indicated. CMCs are expressed as either a specific value that covers the full range or as
a combination of the fraction/percent of the reading/output plus a range specification.
4 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted.
5 CMC is defined at 1 kHz only. The laboratory implements the IET Uncertainty calculator for intermediate
values and frequencies.
6 CMC is defined at 1 kHz only. The laboratory implements the IET Uncertainty calculator for intermediate
values and frequencies which utilizes the “AH2700a Complete Specifications in Excel” spreadsheet from
Andeen-Hagerling.
7 This laboratory meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter | ||
| 12 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Hayes Instrument ServiceBillerica, MA · ~32 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - BostonBillerica, MA · ~32 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Cal-Tek CompanyNorth Billerica, MA · ~36 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Hitachi High-Tech AmericaWestford, MA · ~40 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Associated Environmental SystemsNorth Chelmsford, MA · ~44 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.