United States

IET Labs, Inc.

1202 VFW Parkway, 02132, West Roxbury, MA, United States

Visit website
A2LA 2073.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
12
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 12 scope lines.

A2LA certificate 2073.01 · 12 lines

LineMethodMatrixRange
1ISO 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2073.01) 03/13/2024 Page 2 of 11 Parameter/Equipment Range CMC2, 4, 8 (±) Comments DC Resistance – Measure (cont) (1 to 2) Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ (2 to 20) GΩ (20 to 200) GΩ 200 GΩ to 1 TΩ (1 to 2) TΩ (2 to 20) TΩ (20 to 200) TΩ 7 µΩ/Ω + 2.4 µΩ 4 µΩ/Ω + 10 µΩ 2.7 µΩ/Ω + 20 µΩ 3.8 µΩ/Ω + 60 µΩ 0.9 µΩ/Ω + 2 mΩ 2.7 µΩ/Ω + 10 mΩ 3 µΩ/Ω + 0.6 Ω 6.3 µΩ/Ω + 2 Ω 8.5 µΩ/Ω 0.0026 % 0.03 % 0.032 % 0.35 % 0.5 % 1.5 % 2.5 % Ratio transfer method Voltage characterization method w/standards Keithley 6517A w/ faraday cage DC Resistance – Generate, Fixed Points 0.1 mΩ 1 mΩ 10 mΩ 100 mΩ 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 10 TΩ 4 µΩ/Ω 4 µΩ/Ω 4 µΩ/Ω 4 µΩ/Ω 4 µΩ/Ω 4 µΩ/Ω 1 µΩ/Ω 1.7 µΩ/Ω 0.5 µΩ /Ω 3.7 µΩ/Ω 3.7 µΩ/Ω 6.2 µΩ/Ω 10 µΩ/Ω 100 µΩ/Ω 100 µΩ/Ω 0.020 % 0.025 % 0.10 % Otto Wolff 15283/61 L&N 4223-B Guildline 9334A SRL-0.1 SRL-1 SRL-10 IET (esi) SR-102 Guildline 9334A IET (esi) SR-104 SRL-100k SRL-1M SRL-10M Guildline 9334A SRL-1G SRC-10G SRL-100G OhmLabs 112 OhmLabs 113
to 200 TΩ
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2073.01) 03/13/2024 Page 3 of 11 Parameter/Range Frequency CMC2, 4, 8 (±) Comments Capacitance – Measure5 10 aF to 11 μF 10 aF to 100 mF 10 aF to 10 F 50 Hz to 1 kHz 12 Hz to 200 kHz 10 Hz to 2 MHz 0.010 % + 30 aF 0.010 % + 16 fF 0.050 % + 30 fF IET (GenRad) 1620 IET (GenRad) 1689/1693 IET (Quadtech) 7600+ Capacitance – Measure6 1 fF to 1 μF 50 Hz to 20 kHz 5.5 µF/F + 1 aF Direct measurement using capacitance bridge AH 2700A bridge Dissipation Factor – Measure 6 1 µ to 10 (unitless) 50 Hz to 20 kHz 0.024 % + 5 µ (unitless) Direct measurement using capacitance bridge AH 2700A bridge Capacitance – Generate 1 fF to 11 μF 1 fF to 100 mF 1 fF to 10 F Fixed Points: 1 pF 10 pF 100 pF 1000 pF 10 nF 100 nF 1 µF 10 µF 100 µF 1 mF 10 mF 100 mF 1 F 50 Hz to 1 kHz 12 Hz to 200 kHz 10 Hz to 2 MHz 1 kHz 100 Hz 0.010 % + 30 aF 0.010 % + 16 fF 0.050 % + 30 fF 84 µF/F 1.3 µF/F 1.1 µF/F 1.4 µF/F 0.012 % 0.014 % 0.013 % 0.015 % 0.043 % 0.23 % 0.38 % 0.34 % 0.41 % Various standard capacitors characterized at time of use 5 IET (Genrad) 1403 IET (GenRad) 1404-C IET (GenRad) 1404-B IET (GenRad) 1404-A IET SC-10 nF IET SC-100 nF IET SC-1 µF IET SC-10 µF IET S-100 µF IET (GenRad) 1417 IET (GenRad) 1417 IET (GenRad) 1417 IET (GenRad) 1417
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2073.01) 03/13/2024 Page 4 of 11 Parameter/Range Frequency CMC2, 4, 8 (±) Comments Capacitance – Generate (cont) Fixed Points Algorithmic Derivation @ Freq: 50 pF 100 pF 200 pF 500 pF 1 nF 2 nF 10 nF 20 nF 50 nF 100 nF 1 kHz to 1 MHz 0.017 % 0.021 % 0.014 % 0.012 % 0.013 % 0.016 % 0.057 % 0.12 % 0.028 % 0.56 % Various standard capacitors characterized at time of use 5 GR/IET 1406E GR/IET 1406D GR/IET 1406C GR/IET 1406B GR/IET 1406A GR/IET 1407B GR/IET 1407D GR/IET 1407E GR/IET 1407F GR/IET 1407G Inductance – Measure5 10 nH to 100 kH 1 pH to 100 H 12 Hz to 100 kHz 10 Hz to 2 MHz 0.01 % + 50 nH 0.05 % + 120 pH IET (GenRad) 1689/1693 IET (Quadtech) 7600+ Inductance – Measure, Fixed Points 10 μH 50 μH 100 μH 200 μH 100 Hz 400 Hz 1 kHz 10 kHz 100 kHz 100 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 400 Hz 1 kHz 10 kHz 1.5 % 0.29 % 0.12 % 0.07 % 0.10 % 0.31 % 0.08 % 0.04 % 0.06 % 0.017 % 0.017 % 0.017 % 0.011 % 0.017 % 0.1 % 0.04 % 0.03 % 0.06 % IET (GenRad) 1482 standard inductors w/ precision LCR meter
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2073.01) 03/13/2024 Page 5 of 11 Parameter/Range Frequency CMC2, 4, 8 (±) Comments Inductance – Measure, Fixed Points (cont) 500 μH 1 mH 2 mH 5 mH 10 mH 20 mH 50 mH 100 mH 100 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 400 Hz 1 kHz 10 kHz 100 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 0.06 % 0.03 % 0.02 % 0.06 % 0.012 % 0.012 % 0.012 % 0.011 % 0.017 % 0.04 % 0.03 % 0.02 % 0.06 % 0.03 % 0.02 % 0.02 % 0.06 % 0.013 % 0.013 % 0.013 % 0.011 % 0.015 % 0.03 % 0.02 % 0.02 % 0.07 % 0.015 % 0.015 % 0.015 % 0.014 % 0.023 % 0.012 % 0.012 % 0.012 % 0.011 % 0.021 % IET (GenRad) 1482 standard inductors with precision LCR meter
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2073.01) 03/13/2024 Page 6 of 11 Parameter/Range Frequency CMC2, 4, 8 (±) Comments Inductance – Measure, Fixed Points (cont) 200 mH 500 mH 1 H 2 H 5 H 10 H 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 100 Hz 400 Hz 1 kHz 100 Hz 200 Hz 400 Hz 1 kHz 100 Hz 200 Hz 400 Hz 1 kHz 0.015 % 0.015 % 0.015 % 0.014 % 0.051 % 0.015 % 0.015 % 0.015 % 0.014 % 0.051 % 0.011 % 0.011 % 0.011 % 0.011 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.04 % 0.012 % 0.012 % 0.012 % 0.011 % IET (GenRad) 1482 standard inductors w/ precision LCR meter Inductance – Generate, Fixed Points 10 µH 50 µH 100 Hz 400 Hz 1 kHz 10 kHz 100 kHz 100 Hz 400 Hz 1 kHz 10 kHz 1.5 % 0.29 % 0.12 % 0.07 % 0.10 % 0.31 % 0.08 % 0.04 % 0.06 % IET (GenRad) 1482 standard inductors
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2073.01) 03/13/2024 Page 7 of 11 Parameter/Range Frequency CMC2, 4, 8 (±) Comments Inductance – Generate, Fixed Points (cont) 100 µH 200 µH 500 µH 1 mH 2 mH 5 mH 10 mH 20 mH 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 400 Hz 1 kHz 10 kHz 100 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 400 Hz 1 kHz 10 kHz 100 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 400 Hz 1 kHz 10 kHz 0.017 % 0.017 % 0.017 % 0.011 % 0.017 % 0.1 % 0.04 % 0.03 % 0.06 % 0.06 % 0.03 % 0.02 % 0.06 % 0.012 % 0.012 % 0.012 % 0.011 % 0.017 % 0.04 % 0.03 % 0.02 % 0.06 % 0.03 % 0.02 % 0.02 % 0.06 % 0.013 % 0.013 % 0.013 % 0.011 % 0.015 % 0.03 % 0.02 % 0.02 % 0.07 % IET (GenRad) 1482 standard inductors
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2073.01) 03/13/2024 Page 8 of 11 Parameter/Range Frequency CMC2, 4, 8 (±) Comments Inductance – Generate, Fixed Points (cont) 50 mH 100 mH 200 mH 500 mH 1 H 2 H 5 H 10 H 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 10 kHz 100 Hz 200 Hz 400 Hz 1 kHz 100 Hz 400 Hz 1 kHz 100 Hz 400 Hz 1 kHz 100 Hz 200 Hz 400 Hz 1 kHz 0.015 % 0.015 % 0.015 % 0.014 % 0.023 % 0.012 % 0.012 % 0.012 % 0.011 % 0.021 % 0.015 % 0.015 % 0.015 % 0.014 % 0.051 % 0.015 % 0.015 % 0.015 % 0.014 % 0.051 % 0.011 % 0.011 % 0.011 % 0.011 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.04 % 0.012 % 0.012 % 0.012 % 0.011 % IET (GenRad) 1482 standard inductors
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2073.01) 03/13/2024 Page 9 of 11 Parameter/Equipment Range CMC2, 3, 8 (±) Comments DC Voltage – Generate, Cardinal Points 10 V 17 µV/V Fluke 732A DC Voltage – Measure (0 to 200) mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1000) V 4.5 µV/V + 0.1 µV 3 µV/V + 0.4 µV 3 µV/V + 4 µV 4.5 µV/V + 40 µV 4.5 µV/V + 0.5 mV Fluke 8508A DC Current – Measure (0 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A 12 µA/A + 0.2 nA 12 µA/A + 2 nA 13 µA/A + 20 nA 36 µA/A + 0.4 µA 0.017 % + 8 µA 0.038 % + 20 µA Fluke 8508A Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Measure (0 to 200) mV (0.2 to 2) V (2 to 20) V (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 0.013 % + 4 µV 0.011 % + 4 µV 0.011 % + 2 µV 0.011 % + 4 µV 0.030 % + 8 µV 0.071 % + 20 µV 0.011 % + 20 µV 85 µV/V + 20 µV 65 µV/V + 20 µV 85 µV/V + 20 µV 0.021 % + 40 µV 0.051 % + 200 µV 0.3 % + 2 mV 1 % + 2 mV 0.011 % + 200 µV 85 µV/V + 200 µV 65 µV/V + 200 µV 85 µV/V + 200 µV 0.021 % + 400 µV 0.051 % + 2 mV 0.3 % + 20 mV 1 % + 20 mV Fluke 8508A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2073.01) 03/13/2024 Page 10 of 11 Parameter/Range Frequency CMC2, 3, 4, 8 (±) Comments AC Voltage – Measure (cont) (20 to 200) V (200 to 1050) V (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz (40 to 10) kHz (10 to 30) kHz (30 to 100) kHz 0.011 % + 2 mV 85 µV/V + 2 mV 65 µV/V + 2 mV 85 µV/V + 2 mV 0.021 % + 4 mV 0.051 % + 20 mV 0.3 % + 200 mV 1 % + 200 mV 0.011 % + 0.02 V 95 µV/V + 0.02 V 0.021 % + 0.04 V 0.051 % + 0.2 V Fluke 8508A AC Current – Measure (0 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 10 kHz (10 to 30) kHz (30 to 100) kHz 10 Hz to 2 kHz (2 to 10) kHz 0.028 % + 0.02 µA 0.065 % + 0.02 µA 0.4 % + 0.02 µA 0.028 % + 0.2 µA 0.065 % + 0.2 µA 0.4 % + 0.2 µA 0.028 % + 2 µA 0.065 % + 2 µA 0.4 % + 2 µA 0.025 % + 20 µA 0.060 % + 20 µA 0.060 % + 200 µA 0.070 % + 200 µA 0.3 % + 200 µA 0.08 % + 2 mA 0.25 % + 2 mA Fluke 8508A AC Resistance – Measure 5 0.01 mΩ to 100 MΩ 0.1 mΩ to 100 MΩ 12 Hz to 200 kHz 10 Hz to 2 MHz 0.02 % 0.05 % IET (GenRad) 1689/1693 Quadtech 7600
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2073.01) 03/13/2024 Page 11 of 11 Parameter/Range Frequency CMC2, 8 (±) Comments AC Resistance – Generate Fixed Points: 24.9 Ω 374 Ω 5.97 kΩ 95.317 kΩ 1 kHz 1 kHz 1 kHz 1 kHz 20 µΩ/Ω 20 µΩ/Ω 20 µΩ/Ω 20 µΩ/Ω IET (GenRad) 1689-9604 Digibridge calibration kit II. Time & Frequency Parameter/Equipment Range CMC 2, 8 (±) Comments Frequency – Measure 0.01 Hz to 125 MHz 20 µHz/Hz Precision counter __________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The measurands stated are measured with the Fluke 8508A. This capability is suitable for the calibration of the parameters indicated. CMCs are expressed as either a specific value that covers the full range or as a combination of the fraction/percent of the reading/output plus a range specification. 4 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted. 5 CMC is defined at 1 kHz only. The laboratory implements the IET Uncertainty calculator for intermediate values and frequencies. 6 CMC is defined at 1 kHz only. The laboratory implements the IET Uncertainty calculator for intermediate values and frequencies which utilizes the “AH2700a Complete Specifications in Excel” spreadsheet from Andeen-Hagerling. 7 This laboratory meets A2LA’s P112 Flexible Scope Policy. 8 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter
12ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1202 VFW Parkway, West Roxbury, MA, 02132, US

42.27848, -71.16337

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.