Electromagnetic Testing Services
Pratts Fields, Lubberhedges Lane, Stebbing, Dunmow, CM6 3BT, Essex, United Kingdom
Visit website- Accredited standards
- 12
- UKAS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the UKAS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 12 standard numbers and the 12 official names we hold. When no standard matches, it searches the method text of every scope line.
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements
IEC 61000 series3
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
ISO3
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
Other standards2
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
EN 55022:2006; EN 55022:2006 + A1; EN 55022:2010; EN 55011:2007; EN 55011:2009 + A1; EN 55011:2016; EN 55032:2015; EN 55014-1:2006 + A1:2009 + A2:2011
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 7637-2:2004; ISO 11452-4:2005 2; ISO 11452-2:2004 Absorption Chamber Substitution method 20 MHz to 2 GHz 30 V/m UN Reg 10; IEC 17025
ANSI C63.4-2014; FCC CFR 47 Part 15 B; FCC MP-5 (February 1986); FCC CFR 47 Part 18
Read from the scope as published by UKAS. Register refreshed 2026-11-20.
Scope as published by UKAS
4 lines
ISO/IEC 17025
Active4416
Accredited scope, certificate 4416
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | EN 55022:2006; EN 55022:2006 + A1; EN 55022:2010; EN 55011:2007; EN 55011:2009 + A1; EN 55011:2016; EN 55032:2015; EN 55014-1:2006 + A1:2009 + A2:2011 | Electrical Electronic Components; Electrical Electronic Products; Electro Mechanical Devices; IT Equipment; Industrial Equipment; Scientific Equipment; Certain Medical Equipment | See scope document |
| 2 | ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-6 | Electrical Electronic Components; Electrical Electronic Products; Electro Mechanical Devices; IT Equipment; Industrial Equipment; Scientific Equipment; Certain Medical Equipment | to 30000 V |
| 3 | ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 7637-2:2004; ISO 11452-4:2005 2; ISO 11452-2:2004 Absorption Chamber Substitution method 20 MHz to 2 GHz 30 V/m UN Reg 10; IEC 17025 | Automotive ESA Section 2 | 150000 to 108000000 Hz |
| 4 | ANSI C63.4-2014; FCC CFR 47 Part 15 B; FCC MP-5 (February 1986); FCC CFR 47 Part 18 | Unintentional Radiators; Consumer ISM Equipment | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United Kingdom
- Element Materials Technology WarwickWorcestershire · ~189 kmUKASShares 2 accredited test methodsANSI C63.4-2014IEC 61000-4-2
- Kiwa Ltd t/a Kiwa Electrical ComplianceEssex · ~31 kmUKASShares 1 accredited test methodANSI C63.4-2014
- Intertek Testing & CertificationLeatherhead · ~86 kmUKASShares 1 accredited test methodANSI C63.4-2014
- TUV SUD Limited (Trading as TUV SUD)Hampshire · ~164 kmUKASShares 1 accredited test methodANSI C63.4-2014
- Eurofins Electrical & Electronic UKCastleford · ~233 kmUKASShares 1 accredited test methodANSI C63.4-2014
Accreditation data refreshed from the UKAS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.