ENI Labs
3120 Independence Dr., 46808, Fort Wayne, IN, United States
Visit website- Scope lines
- 53
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 53 scope lines.
A2LA certificate 2147.01 · 53 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 2 of 52
III. Dimensional
Parameter/Equipment
Range CMC2, 6 (±) Comments
Calipers3 – Dial, Digital,
Vernier –
Length
Parallelism
Up to 18 in
(18 to 48) in
Up to 2 in
(290 + 7.3L) µin
(240 + 4.9L) µin
30 µin
Gage blocks
Depth Gauge3 – Dial,
Digital, Vernier
(0.001 to 48) in
(59 + 7.2L) µin
Gage blocks, surface plate
Gage Blocks –
Flatness
Up to 10 in
Up to 4 in
4 to 24 in
Up to 2 in
(5.0 + 0.95L) µin
(5.4 + 0.75L) µin
(5.0 + 0.95L) µin
2.5 µin
Pratt & Whitney
Labmaster
TM LMU-175,
gauge blocks, optical flat
Mahr comparator, gauge
blocks, optical flat
Height Gauges3
Up to 18 in
(18 to 36) in
(30 + 6.5L) µin
(16 + 7.3L) µin
Gage blocks
Indicators – Dial &
Digital3
(0.000 01 to 2) in
(11 + 8.9L) µin
Gage blocks, surface plate,
Pratt&Whitney SupermicTM
Length Standards3
(Length only)
Up to 10 in
(10 to 20) in
(20 to 96) in
(3.2 + 1.0L) µin
(7.8 + 15L) µin
(45 + 17L) µin
Pratt&Whitney
LabmasterTM LMU-175,
micrometer head, gage
blocks, P&W PC25
Measuring Rule3
Up to 48 in
(300 + 4.0L) µin
Hexagon Optiv Classic 321
Measuring Tapes3,6
Up to 300 in
0.015 + (0.004S) in
Master ruler, measuring tape
fixture
Micrometers3 –
OD
ID
Flatness
Parallelism
Up to 48 in
Up to 24 in
Up to 2 in
Up to 2 in
(30 + 13L) µin
(30 + 13L) µin
4.3 µin
4.3 µin
Gage blocks
Optical flat | to 18 in |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 3 of 52
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Optical Comparators3 –
Angularity
Linearity X-Y
Magnification
(0 to 180)°
Up to 12 in
Up to 50X
0.79 arc min
160 µin
0.0035 in
Sine bar, gage blocks
Glass scale
Magnification master, pin
gauge
Plain Gage3 –
Pins & Plugs
Rings
Up to 1 in
(1 to 10) in
(10 to 20) in
Up to 1 in
(1 to 10) in
(7.8 + 9.1L) µin
(2.9 + 14L) µin
(11 + 13L) µin
(6.3 + 12L) µin
(2.4 + 16L) µin
Pratt & Whitney LabmasterTM
LMU-175, gage blocks, P&W
PC25
Protractors3
Up to 90°
0.060°
Surface plate, sine bar, gage
blocks
Sine Bars –
Length
Parallelism
(5 to 10) in
(5 to 10) in
(76 + 4.6L) µin
29 µin
Hexagon Optiv Classic 321,
Hexagon Global S Chrome
Electronic gauge head
Surface Plates3 –
Flatness
Repeatability
Up to 170 in diagonal
(-0.002 to 0.002) in
(7.1 √D) µin
28 µin
Mahr Federal EMD-832-W3
electronic level
Rahn Repeat-O-Meter
Thickness Gauge3
(Feeler Type)
(0.001 to 1) in
(8.6 + 30L) µin
Pratt & Whitney LabmasterTM
LMU-175
Thickness Gauge3
(Ultrasonic)
(0.001 to 8) in
590 µin
Gage blocks | ||
| 4 | ASME/ANSI B1.2-1983; ASME/ANSI B1.3-2007 | - | to 4 in |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 5 of 52
V. Electrical DC/Low Frequency
Parameter/Equipment
Range CMC2, 7 (±) Comments
DC Voltage3 – Generate
Fixed point
10 V
0.5 µV/V
Fluke 732B
DC Voltage3 – Measure
0 V Short
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 10) kV
(10 to 100) kV
(100 to 125) kV
(125 to 140) kV
0.62 µV/V
2.7 µV/V + 0.84 µV
2.0 µV/V + 5.7 µV
4.4 µV/V + 88 µV
1.5 µV/V + 2.0 mV
5.3 µV/V + 2.0 mV
0.35 mV/V + 35 mV
0.58 mV/V + 0.50 V
0.17 kV
0.29 kV
Copper short
HP 3458A Opt. 002
digital multimeter
Vitrek 4700 high voltage
multimeter, Vitrek HVL-
150 high voltage probe
DC Voltage3 – Generate
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
(0.1 to 1.0) kV
(1.0 to 4.0) kV
(4.0 to 9.0) kV
(9.0 to 25) kV
(25 to 50) kV
(50 to 60) kV
9.6 µV/V + 0.63 µV
4.3 µV/V + 4.4 µV
4.0 µV/V + 4.5 µV
4.1 µV/V + 4.9 µV
5.7 µV/V + 98 µV
7.8 µV/V + 660 µV
0.61 V
2.5 V
4.7 V
38 V
58 V
81 V
Fluke 5700A
HV Source monitored by
Vitric 4700
HV Source monitored
by Vitrek 4700/HVL150
probe | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 6 of 52
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Current3 –
Measure
Generate
Clamp Meters
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
(10 to 1000) A
(1 to 2.8) kA
10 µA
100 µA
1 mA
10 mA
20 mA
200 mA
2 A
20 A
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(20.5 to 1000) A
36 µA/A + 0.5 nA
31 µA/A + 5 nA
32 µA/A + 50 nA
52 µA/A + 0.5 µA
0.15 mA/A + 5uA
0.26 mA/A
4.2 mA/A + 0.5A
12 mA/A + 0.5A
12 µA/A
12 µA/A
24 µA/A
24 µA/A
24 µA
24 µA
26 µA
32 µA
10 nA/A + 7.1 nA
8.7 nA/A + 13 nA
8.7 nA/A + 49 nA
1.1 nA/A + 0.84 µA
2.0 nA/A + 31 µA
400 µA/A + 1.5 mA
1 mA/A + 2.4 mA
1.1 mA/A + 2.4 mA
6.0 mA/A + 0.60 A
HP 3458A opt. 002
digital multimeter
Y5020
LEM PR2000 current
clamp, HP 3458A opt.
002 digital multimeter
HP 3458A opt. 002,
Fluke A40B series
current shunts
Fluke 5700A
Fluke 5520A
Fluke 5520A w/ coil | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 7 of 52
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Resistance3 – Generate
Fixed
0.000 333 3 Ω
0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
100Ω
1k Ω
10 kΩ
10 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
1.2 mΩ/Ω
0.58 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.32 kΩ
0.56 MΩ
0.61 MΩ
0.12 GΩ
2.6 GΩ
47 µΩ
110 µΩ
110 µΩ
35 µΩ
43 µΩ
0.15 mΩ
0.28 mΩ
1.6 mΩ
2.9 mΩ
15 mΩ
29 mΩ
0.18 Ω
0.30 Ω
17 Ω
19 Ω
71 Ω
250 Ω
4.2 kΩ
9211A Guildline
Metrohm P4085 series
resistors
Fluke 5720A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 8 of 52
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Resistance3 – Measure
(0 to 10) Ω
(10 to 100) Ω
(100 to 1000) Ω
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 100) MΩ
100 MΩ to 1 GΩ
Up to 2 Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
(2 to 20) GΩ
29 µΩ/Ω + 0.58 mΩ
12 µΩ/Ω + 0.58 mΩ
12 µΩ/Ω + 5.8 mΩ
12 µΩ/Ω + 58 mΩ
18 µΩ/Ω + 2.3 Ω
58 µΩ/Ω + 0.12 kΩ
5.8 mΩ/Ω + 12 kΩ
5.8 mΩ/Ω + 12 kΩ
28 µΩ/Ω
25 µΩ/Ω
17 µΩ/Ω
14 µΩ/Ω
14 µΩ/Ω
14 µΩ/Ω
19 µΩ/Ω
28 µΩ/Ω
0.014 %
0.12 %
0.23 %
HP 3458A Opt. 002,
digital multimeter
Fluke 8508A
Resistance3 – Generate
(0 to 1) Ω
(1 to 1.9) Ω
(1.9 to 10) Ω
(10 to 19) Ω
(19 to 100) Ω
(100 to 190) Ω
(190 to 1000) Ω
(1000 to 1900) Ω
(1.9 to 10) kΩ
(10 to 19) kΩ
(19 to 100) kΩ
(100 to 190) kΩ
(0.19 to 1) MΩ
(1 to 1.9) MΩ
(1.9 to 100) MΩ
46 µΩ/Ω + 1.2 mΩ
46 µΩ/Ω + 1.2 mΩ
46 µΩ/Ω + 1.2 mΩ
34 µΩ/Ω + 1.8 mΩ
28 µΩ/Ω + 3.5 mΩ
28 µΩ/Ω + 3.5 mΩ
29 µΩ/Ω + 6.3 mΩ
27 µΩ/Ω + 4.0 mΩ
26 µΩ/Ω + 100 mΩ
27 µΩ/Ω + 40 mΩ
26 µΩ/Ω + 1 Ω
33 µΩ/Ω + 3.4 Ω
30 µΩ/Ω + 11 Ω
63 µΩ/Ω + 0.05 kΩ
0.52 mΩ/Ω + 10 kΩ
Fluke 5520A
Resistance3 – Current
Shunt
Up to 80 mΩ
(80 to 800) mΩ
(0.8 to 1000) Ω
320 µΩ/Ω + 1.3 nΩ
140 µΩ/Ω + 4.7 nΩ
81 µΩ/Ω + 16 µΩ
Fluke 5520A, HP
3458A Opt.002
digital multimeter | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 9 of 52
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 – Measure
(0 to 2.2) mV
(2.2 to 7) mV
(7 to 22) mV
(22 to 70) mV
(70 to 220) mV
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
0.43 mV/V + 1.5 µV
0.25 mV/V + 1.5 µV
0.25 mV/V + 1.5 µV
0.46 mV/V + 2.3 µV
0.69 mV/V + 2.9 µV
1.4 mV/V + 4.6 µV
1.5 mV/V + 9.2 µV
2.7 mV/V + 9.2 µV
0.22 mV/V + 1.5 µV
0.13 mV/V + 1.5 µV
0.13 mV/V + 1.5 µV
0.24 mV/V + 2.3 µV
0.36 mV/V + 2.9 µV
0.95 mV/V + 4.6 µV
1.0 µV/V + 9.2 µV
2.0 mV/V + 9.2 µV
0.15 mV/V + 1.8 µV
78 µV/V + 1.8 µV
78 µV/V + 1.8 µV
0.14 mV/V + 3.1 µV
0.24 mV/V + 5.9 µV
0.63 mV/V + 4.7 µV
0.82 mV/V + 9.3 µV
1.3 mV/V + 9.3 µV
99 µV/V + 1.9 µV
45 µ/V + 1.9 µV
45 µV/V + 1.9 µV
70 µV/V + 4.1 µV
0.14 mV/V + 9.8 µV
0.31 mV/V + 5.0 µV
0.45 mV/V + 9.5 µV
1.2 mV/V + 9.6 µV
15 µV/V + 77 µV
3.6 µV/V + 65 µV
3.6 µV/V + 65 µV
6.6 µV/V + 85 µV
7.8 µV/V + 0.15 mV
24 µV/V + 0.28 mV
59 µV/V + 0.28 mV
0.44 mV/V + 0.28 mV
Fluke 5790A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 10 of 52
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage3 – Measure
(cont)
(220 to 700) mV
(0.7 to 2.2) V
(2.2 to 7) V
(7 to 22) V
(22 to 70) V
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
12 µV/V + 0.17 mV
3.4 µV/V + 83 µV
3.4 µV/V + 84 µV
24 µV/V + 36 µV
39 µV/V + 49 µV
44 µV/V + 0.34 mV
92 µV/V + 0.35 mV
0.68 µV/V + 0.36 mV
28 µV/V + 0.22 mV
15 µV/V + 45 µV
15 µV/V + 45 µV
52 µV/V + 16 µV
83 µV/V + 26 µV
0.22 mV/V + 50 µV
0.13 mV/V + 1.7 mV
0.89 mV/V + 1.5 mV
70 µ/V + 80 µV
25 µ/V + 59 µV
25 µV/V + 59 µV
49 µV/V + 59 µV
87 µV/V + 52 µV
0.23 mV/V + 40 µV
0.45 mV/V + 0.19 mV
1.3 mV/V + 0.43 mV
76 µV/V + 0.12 mV
34 µV/V + 0.10 mV
34 µV/V + 0.10 mV
62 µV/V + 0.10 mV
100 µV/V + 0.30 mV
0.20 mV/V + 0.86 mV
0.45 mV/V + 0.75 mV
1.4 mV/V + 0.58 mV
75 µV/V + 0.51 mV
30 µV/V + 0.64 mV
30 µV/V + 0.64 mV
74 µV/V + 0.51 mV
100 µV/V + 1.1 mV
0.21 vmV/V + 2.8 mV
0.57 mV/V + 1.0 mV
Fluke 5790A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 11 of 52
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage3 – Measure
(cont)
(70 to 220) V
(220 to 700) V
(700 to 1000) V
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
80 µV/V + 0.51 mV
35 µV/V + 0.64 mV
35 µV/V + 0.64 mV
78 µV/V + 0.51 mV
0.11 mV/V + 1.1 mV
0.23 mV/V + 2.8 mV
0.58 mV/V + 1.0 mV
0.11 mV/V + 4.2 mV
43 µV/V + 3.4 mV
43 µV/V + 3.4 mV
90 µV/V + 64 mV
0.31 mV/V + 0.27 V
0.11 mV/V + 4.2 mV
44 µV/V + 3.4 mV
44 µV/V + 3.4 mV
0.11 mV/V + 64 mV
0.37 mV/V + 0.27 V
Fluke 5790A
AC Voltage – Wideband
Measure
(0 to 2.2) mV
(2.2 to 7) mV
(7 to 22) mV
(22 to 70) mV
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
7.9 mV/V + 1.9 µV
7.5 mV/V + 1.9 µV
7.5 mV/V + 1.9 µV
7.5 mV/V + 1.9 µV
7.7 mV/V + 3.0 µV
7.7 mV/V + 2.6 µV
7.2 mV/V + 2.6 µV
7.2 mV/V + 2.6 µV
7.2 mV/V + 2.6 µV
7.4 mV/V + 3.7 µV
7.4 mV/V + 4.9 µV
6.9 mV/V + 4.9 µV
6.9 mV/V + 4.9 µV
6.9 mV/V + 4.9 µV
7.0 mV/V + 6.6 µV
7.4 mV/V + 6.1 µV
6.8 mV/V + 6.1 µV
6.8 mV/V + 6.1 µV
6.8 mV/V + 6.1 µV
6.7 mV/V + 6.1 µV
Fluke 5790A w/
wideband opt. | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 12 of 52
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage – Wideband
Measure (cont.)
(70 to 220) mV
(220 to 700) mV
(0.7 to 2.2) V
(2.2 to 7) V
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
(10 to 30) Hz
(30 to 120) Hz
(0.12 to 1.2) kHz
(1.2 to 120) kHz
(120 to 500) kHz
7.0 mV/V + 35 µV
6.4 mV/V + 35 µV
6.4 mV/V + 35 µV
6.4 mV/V + 35 µV
6.4 mV/V + 35 µV
5.8 mV/V + 93 µV
5.1 mV/V + 93 µV
5.1 mV/V + 93 µV
5.1 mV/V + 93 µV
5.1 mV/V + 93 µV
5.7 mV/V + 0.35 mV
5.0 mV/V + 0.35 mV
5.0 mV/V + 0.35 mV
5.0 mV/V + 0.35 mV
5.0 mV/V + 0.35 mV
5.2 mV/V + 0.49 mV
4.4 mV/V + 0.49 mV
4.4 mV/V + 0.49 mV
4.4 mV/V + 0.49 mV
4.4 mV/V + 0.49 mV
Fluke 5790A w/
wideband opt.
AC Voltage3 – Generate
(0.005 to 2.2) mV
(2.2 to 220) mV
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
0.022 % + 5.2 µV
0.011 % + 5.2 µV
0.011 % + 5.2 µV
0.038 % + 5.2 µV
0.087 % + 8.1 µV
0.12 % + 15 µV
0.17 % + 29 µV
0.36 % + 29 µV
0.022 % + 9.5 µv
0.011 % + 9.6 µv
0.011 % + 9.4 µV
0.018 % + 62 µV
0.058 % + 130 µV
0.11 % + 37 µV
0.18 % + 41 µV
0.37 % + 93 µV
Fluke 5700A | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 13 of 52
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 – Generate
(cont)
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(220 to 750) V
(220 to 750) V
(750 to 1050) V
(1 to 33) mV
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(15 to 50) Hz
(0.05 to 1) kHz
(0.03 to 10) kHz
(10 to 33) kHz
(33 to 100) kHz
(0.04 to 10) kHz
(10 to 33) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
0.016 % + 48 µV
0.074 % + 14 µV
0.075 % + 11 µV
29 µV/V + 0.70 mV
0.016 % + 0.38 mV
0.046 % + 0.15 mV
0.11 % + 0.42 mV
0.22 % + 1.0 mV
0.016 % + 0.38 mV
73 µV/V + 0.15 mV
75 µV/V + 0.12 mV
0.011 % + 0.82 mV
0.024 % + 0.47 mV
0.053 % + 1.7 mV
0.14 % + 5.0 mV
0.29 % + 1.0 mV
0.17 % + 3.9 mV
80 µV/V + 1.6 mV
82 µV/V + 1.2 mV
0.023 % + 4.2 mV
0.53 % + 9.5 mV
0.17 % + 0.11 V
0.53 % + 0.11 V
1.3 % + 0.22 V
0.043 % + 19 mV
77 µV/V + 9.3 mV
29 µV/V
0.13 mV/V
0.58 mV/V
29 µV/V
0.13 mV/V
99 µV/V + 19 µV
99 µV/V + 19 µV
9.3 µV/V + 250 µV
48 µV/V + 140 µV
0.045 % + 100 µV
0.22 % + 87 µV
Fluke 5700A
Wavetek 4808
Monitored with
Fluke5790A
Fluke 5520A | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 14 of 52
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage3 – Generate
(cont)
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(0.1 to 1.0) kV
(1.0 to 4.0) kV
(4.0 to 9.0) kV
(9.0 to 10) kV
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(0.045 to 1) kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(50 to 60) Hz
(50 to 60) Hz
(50 to 60) Hz
(50 to 60) Hz
0.012 % + 0.12 mV
0.012 % + 0.12 mV
13 µV/V + 1.8 mV
35 µV/V + 1.1 mV
0.045 % + 0.43 mV
0.26 % + 0.80 mV
0.017 % + 0.71 mV
0.017 % + 0.71 mV
0.027 % + 0.72 mV
0.040 % + 0.74 mV
0.10 % + 1.9 mV
0.28 % + 0.80 mV
0.021 % + 3.0 mV
0.022 % + 7.8 mV
0.024 % + 10 mV
0.019 % + 20 mV
0.22 % + 62 mV
0.033 % + 19 mV
0.030 % + 32 mV
0.028 % + 11 mV
0.31 % + 20 mV
0.23 % + 63 mV
0.034 % + 19 mV
0.028 % + 20 mV
0.033 % + 32 mV
2.1 V
6.4 V
18 V
0.12 kV
Fluke 5520A
HV source monitored
by Vitrek 4700
HV source monitored
by Vitrek 4700 w/
HVL-150 probe
AC Voltage3 – Measure
10 mV
(10 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
340 µV/V + 3.7 µV
230 µV/V + 1.4 µV
340 µV/V + 1.4 µV
1.2 mV/V + 1.6 µV
5.8 mV/V + 1.5 µV
47 mV/V + 2.7 µV
HP 3458A | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 15 of 52
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage3 – Measure
(cont.)
100 mV
1 V
10 V
100 V
700 V
(1 to 10) kV
(10 to 75) kV
(60.0 to 80) kV
(80.0 to 100.0) kV
(10 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(10 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(10 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 1) MHz
(1 to 2) MHz
(10 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(10 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(0.01 to 600) Hz
(0.01 to 600) Hz
(50 to 60) Hz
(50 to 60) Hz
56 µV/V + 110 µV
73 µV/V + 38 µV
160 µV/V + 35 µV
110 µV/V + 690 µV
0.68 mV/V + 0.33 mV
3.3 mV/V + 0.27 mV
12 mV/V + 97 µV
17 mV/V + 420 µV
56 µV/V + 1.1 mV
65 µV/V + 0.46 mV
0.16 mV/V + 0.35 mV
0.32 mV/V + 0.69 mV 0.92
mV/V + 0.38 mV
3.5 mV/V + 1.6 mV
12 mV/V + 0.97 mV
17 mV/V + 4.3 mV
0.21 mV/V + 7.3 mV
0.23 mV/V + 3.4 mV 0.23
mV/V + 3.3 mV
0.41 mV/V + 3.0 mV
1.4 mV/V + 3.4 mV
4.6 mV/V + 13 mV
17 mV/V + 22 mV
17 mV/V + 22 mV
0.44 mV/V + 54 mV
0.45 mV/ + 30 mV
0.64 mV/V + 34 mV
1.3 mV/V + 40 mV
3.6 mV/V + 20 mV
4.1 mV/V + 0.7 V
18 mV/V + 0.8 V
0.45 mV/V + 37 mV
0.45 mV/V + 37 mV
1.4 mV/V + 42 mV
3.5 mV/V + 42 mV
3.5 mV/V + 42 mV
1.4 mV/V + 0.12 V
1.1 mV/V + 0.77 V
0.49 kV
0.59 kV
Vitrek 4700 high
voltage multimeter
Vitrek 4700 with
HVL-150 high
voltage probe | ||
| 16 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 16 of 52
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current3 – Measure
Up to 100 µA
(1 to 100) mA
(0.1 to 1) A
(1 to 20) A
(20 to 2800) A
10 µA
100 µA
1 mA
10 mA
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 1) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(2 to 10) kHz
3 Hz to 10 kHz
1 Hz to 10 kHz
(0.01 to 1) kHz
(1 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(0.01 to 1) kHz
(1 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(0.01 to 1) kHz
(1 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(0.01 to 1) kHz
(1 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1.9 mA/A + 0.56 µA
0.37 mA/A + 0.58 µA
91 µA/A + 0.58 µA
84 µA/A + 0.57 µA
4.7 mA/A + 24 µA
1.8 mA/A + 24 µA
0.70 mA/A + 24 µA
0.35 mA/A + 24 µA
0.70 mA/A + 24 µA
4.7 mA/A + 47 µA
6.4 mA/A + 170 µA
4.7 mA/A + 0.24 mA
1.9 mA/A + 0.24 mA
0.92 mA/A + 0.25 mA
1.1 mA/A + 0.25 mA
3.5 mA/A + 0.24 mA
12 mA/A + 0.47 mA
0.10 %
0.30 %
12 mA/A
1.2 µA/A
1.1 µA/A
1.1 µA/A
1.9 µA/A
6.8 µA/A
9.0 µA/A
9.1 µA/A
18 µA/A
68 µA/A
90 µA/A
91 µA/A
0.18 mA/A
37 µA/A
37 µA/A
39 µA/A
59 µA/A
HP 3458 opt. 002
digital multimeter
Fluke 8508A
LEM PR2000 current
clamp, HP 3458A opt.
002 digital multimeter
Fluke A40B series
shunts, Fluke 5790 | to 100 µA |
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 17 of 52
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current3 – Measure
(cont)
20 mA
200 mA
2 A
20 A
(0.01 to 1) kHz
(1 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(0.01 to 1) kHz
(1 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(0.01 to 1) kHz
(1 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(0.01 to 1) kHz
(1 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
37 µA/A
37 µA/A
39 µA/A
59 µA/A
37 µA/A
37 µA/A
39 µA/A
59 µA/A
38 µA/A
41 µA/A
43 µA/A
75 µA/A
48 µA/A
63 µA/A
96 µA/A
0.21 mA/A
Fluke A40B series
shunts, Fluke 5790
AC Current3 – Generate
(0.02 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
0.93 mA/A + 30 nA
0.49 mA/A + 25 nA
0.20 mA/A + 20 nA
0.83 mA/A + 50 nA
0.21 % + 0.1 µA
0.93 mA/A + 50 nA
0.49 mA/A + 40 nA
0.19 mA/A + 40 nA
0.82 mA/A + 0.5 µA
0.21 % + 1.0 µA
0.94 mA/A + 0.5 µA
0.49 mA/A + 0.4 µA
0.19 mA/A + 0.4 µA
0.82 mA/A + 5.0 µA
0.21 % + 10 µA
0.93 mA/A + 5.0 µA
0.49 mA/A + 4.0 µA
0.22 mA/A + 4.0 nA
0.82 mA/A + 50 µA
0.21 % + 0.10 mA
Fluke 5700A | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 18 of 52
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current3 – Generate
(cont)
(0.22 to 2.2) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(20.5 to 150) A
Toroidal
Non-Toroidal
(150 to 1000) A
Toroidal
Non-Toroidal
(0.02 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.87 mA/A + 40 µA
0.99 mA/A + 0.10 mA
1.2 % + 0.20 mA
0.21 % + 0.10 mA
0.76 mA/A + 0.10 mA
0.70 % + 1.0 mA
2.9 % + 5.0 mA
0.74 mA/A + 2.0 mA
0.12 % + 2.0 mA
3.5 % + 2.0 mA
0.15 % + 5.0 mA
0.18 % + 5.0 mA
3.5 % + 5.0 mA
0.41 mA/A
0.96 mA/A
8.7 mA/A
14 mA/A
0.41 mA/A
0.96 mA/A
7.9 mA/A
13 mA/A
Fluke 5520A
Fluke 5520A,
5500A/coil | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 19 of 52
Parameter/Equipment
Range CMC2, 7 (±) Comments
DC Watts – Generate3
(0.010 89 to 10.89) mW
(10.890 to 99) mW
(99 to 336.6) W
(336.6 to 3060) W
(3060 to 20 910) W
0.033 %
0.14 %
0.14 %
0.12 %
0.07 %
Fluke 5520A
AC Watts – Generate3
(45 to 65) Hz/PF=1
(0.1089 to 0.297) mW
(0.297 to 2.97) mW
(2.97 to 10.89) mW
(10.89 to 72.60) mW
(72.60 to 1485) mW
(1.485 to 6.765) W
(6.765 to 33.66) W
(33.66 to 336.6) W
(336.6 to 917.9) W
(917.9 to 2244) W
(2244 to 20 910) W
0.17 %
0.13 %
0.12 %
0.24 %
0.23 %
0.21 %
0.19 %
0.22 %
0.21 %
0.23 %
0.13 %
Fluke 5520A
Phase Angle3 –
Measure
(0 to 359.9999) °
Generate
(0 to 999.999) °
10 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 200) kHz
1 Hz to 1 kHz
(1 to 50) kHz
(50 to 200) kHz
0.012°
0.017°
0.051°
0.11°
0.028°
0.056°
0.068°
North Atlantic PAV
2250A
Clarke Hess 5000
Inductance3 –
Measure
Generate
Fixed points
(0.1 to 10) µH
(0.01 to 10) mH
0.01 to 100) mH
(0.1 to 10) kH
(10 to 100) kH
20 mH
100 mH
200 mH
2 H
0.022 µH
0.21 µH
0.02 H
6.4 H
0.61 kH
0.012 mH
0.054 mH
0.12 mH
1.3 mH
HP 4284A
General radio 1482
series inductors | ||
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 20 of 52
Parameter/Equipment
Range CMC2, 7 (±) Comments
Inductance3 – (cont)
Variable
(1 to 10) mH
(10 to 100) mH
(0.1 to 1) H
(1 to 10) H
9.5 µH
0.81 mH
0.011 H
0.2 H
General radio 1490D
Capacitance3 – Fixed
1 nF
2 nF
10 nF
100 nF
200 nF
1 µF
0.50 pF
1.1 pF
5.4 pF
7.4 pF
0.10 nF
0.19 nF
General radio 1409
series standard
capacitors
Capacitance3 –
Measure
Generate
(0 to 1) nF
(0.001 to 10) µF
(0.001 to 10) mF
(0.01 to 110) mF
(0.19 to 0.4) nF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 100) mF
1.1 pF
5.4 nF
0.011 mF
0.28 mF
0.26 % + 13 pF
0.56 % + 12 pF
0.27 % + 13 pF
0.29 % + 120 pF
0.27 % + 140 pF
0.27 % + 390 pF
0.27 % + 1.3 nF
0.27 % + 3.9 nF
0.25 % + 15 nF
0.26 % + 42 nF
0.38 % + 170 nF
0.45 % + 480 nF
0.50 % + 1.4 µF
0.44 % + 4.9 µF
0.26 % + 36 µF
0.78 % + 49 µF
0.83 % + 360 µF
1.1 % + 360 µF
HP 4284A
Fluke 5520A | ||
| 21 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 21 of 52
Parameter/Equipment
Range CMC2, 7 (±) Comments
Thermocouple
Indicating_Simulation3, 1_2
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -30) °C
(-30 to 50) °C
(50 to 500) °C
(500 to 1200) °C
(-200 to -100) °C
(-100 to -30) °C
(-30 to 120) °C
(120 to 1050) °C
(1050 to 1371.1) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to -100) °C
(-100 to 0) °C
(0 to 400) °C
0.58 °C
0.20 °C
0.18 °C
0.20 °C
0.26 °C
0.30 °C
0.29 °C
0.16 °C
0.23 °C
0.35 °C
0.19 °C
0.17 °C
0.15 °C
0.23 °C
0.42 °C
0.24 °C
0.21 °C
0.20 °C
0.28 °C
0.62 °C
0.41 °C
0.37 °C
0.43 °C
0.53 °C
0.41 °C
0.41 °C
0.49 °C
0.64 °C
0.26 °C
0.18 °C
0.15 °C
Fluke 5520A | ||
| 22 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 22 of 52
Parameter/Equipment
Range CMC2 (±) Comments
RTD Simulation3, 1_2
Cu427
Ni120
Pt 385, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
Pt 3916, 100 Ω
Pt 3926, 100 Ω
100 to 260 °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 600) °C
(600 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
0.34 °C
0.085 °C
0.084 °C
0.15 °C
0.090 °C
0.093 °C
0.11 °C
0.13 °C
0.14 °C
0.15 °C
0.25 °C
0.046 °C
0.055 °C
0.13 °C
0.14 °C
0.15 °C
0.17 °C
0.042 °C
0.051 °C
0.061 °C
0.081 °C
0.092 °C
0.12 °C
0.031 °C
0.041 °C
0.052 °C
0.062 °C
0.072 °C
0.23 °C
0.28 °C
0.058 °C
0.067 °C
0.075 °C
0.093 °C
0.11 °C
0.11 °C
0.12 °C
0.24 °C
0.066 °C
0.083 °C
0.11 °C
0.12 °C
0.14 °C
Fluke 5520A | ||
| 23 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 23 of 52
Parameter/Equipment
Range CMC2 (±) Comments
Oscilloscopes –
Amplitude – DC Signal3
50 Ω Load
1 MΩ Load
Amplitude – Square
Wave
50 Ω Load
1 MΩ Load
(0 to 6) V
(0 to 130) V
1 mV
p-p to 6.6 Vp-p;
10 Hz to 10 kHz
1 mV
p-p to 130 Vp-p;
10 Hz to 10 kHz
29 mV/V + 0.58 mV
590 µV/V + 75 µV
29 mV
p-p/Vp-p + 75 µVp-p
280 µV
p-p/Vp-p + 75 µVp-p
5520A-SC1100
multifunction
calibrator w/
oscilloscope opt
Oscilloscopes – Rise Time
(0.001 to 2) MHz
(2 to 10) MHz
(200 to 300) ps
(250 to 350) ps
120 ps
140 ps
5520A-SC1100
multifunction
calibrator w/
oscilloscope opt
Oscilloscopes –
Bandwidth
3
5 mV to 5.5 Vp-p
4 mV to 3.5 V
p-p
Leveled Sine Wave –
Frequency3
Time Marker
50 kHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
50 kHz to 1.1 GHz
2 ns to 20 ms
50 ms to 5 s
58 mVp-p/Vp-p + 470 µVp-p
58 mVp-p/Vp-p + 470 µVp-p
70 mVp-p/Vp-p + 470 µVp-p
120 mVp-p/Vp-p + 470 µVp-p
140 mVp-p/Vp-p + 470 µVp-p
0.58 kHz
2.9 µs/s + 0.15 ps
1.2 ms/s + 58 µs
5520A-SC1100
multifunction
calibrator w/
oscilloscope opt
Dissipation Factor –
Measure (Df)3
1 pF to 100 µF
(0.0001 to 10) Df
3.5 % + 1 cts
Multi-frequency
LCR Meter
cts: Counts of
LSD | 0.0001 to 10 Df |
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 24 of 52
Parameter/Equipment
Range
CMC2 (±)
Comments
Oscilloscopes –
Wave Functions - Square,
Sine, & Triangle3
50 Ω Load
1 MΩ Load
Pulse Characteristics3 –
Pulse Width
Pulse Period
Rise Time – Generate
1.8 mV
p-p to 2.5 Vp-p;
10 Hz to 10 kHz
1.8 mVp-p to 55 Vp-p;
10 Hz to 10 kHz
(4 to 500) ns
200 ns to 20 ms
1 kHz to 2 MHz
(200 to 300) ps
2 to 10 MHz
(200 to 350) ps
35 mV
p-p/Vp-p + 120
µVp-p
35 mVp-p/Vp-p + 120
µVp-p
2.6 ns
150 ps
120 ps
120 ps
5520A-SC1100
multifunction
calibrator w/
oscilloscope opt
IV. Electrical – RF/Microwave
Parameter/Range
Frequency CMC2, 7 (±) Comments
RF Power3 – Measure
(-67 to +20) dB
(-35 to +20) dB
(-30 to +20) dB
10 MHz to 40 GHz
DC to 100 MHz
100 MHz to 4 GHz
(4 to 8) GHz
(8 to 12.4) GHz
(12.4 to 18) GHz
(18 to 26.5) GHz
(26.5 to 30) GHz
(30 to 35) GHz
(35 to 40) GHz
50 MHz to 50 GHz
0.82 dB
0.061 dB
0.077 dB
0.091 dB
0.11 dB
0.13 dB
0.11 dB
0.13 dB
0.14 dB
0.14 dB
0.11 dB
Anritsu MA2444D
Rohde & Schwarz
NRP-Z55
HP 8487A, Agilent
E4418B | ||
| 25 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 25 of 52
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
RF Power – Generate
(-100 to +24) dB
(-100 to +20) dB
(-100 to +18) dB
Leveled Sine Wave –
Generate
(-130 to -94) dBm
(-94 to -84) dBm
(-84 to -74) dBm
(-74 to -48) dBm
(-48 to -17) dBm
(-17 to +14) dBm
(+14 to +20) dBm
(+20 to +24) dBm
1 mHz to 4.024 GHz
(1.4 to 20) GHz
(20 to 26.5) GHz
(10 to 128) MHz
128 MHz to 3 GHz
100 kHz to 10 MHz
(10 to 128) MHz
(128 to 300) MHz
300 MHz to 3 GHz
100 kHz to 10 MHz
(10 to 128) MHz
(128 to 300) MHz
300 MHz to 1.4 GHz
(1.4 to 4) GHz
100 kHz to 10 MHz
(10 to 128) MHz
(128 to 300) MHz
300 MHz to 1.4 GHz
(1.4 to 4) GHz
(10 to 100) kHz
100 kHz to 128 MHz
(128 to 300) MHz
300 MHz to 1.4 GHz
(1.4 to 3) GHz
(3 to 4) GHz
(10 to 100) kHz
100 kHz to 128 MHz
(128 to 300) MHz
300 MHz to 1.4 GHz
(1.2 to 4) GHz
(10 to 100) kHz
100 kHz to 128 MHz
(128 to 300) MHz
300 MHz to 1.4 GHz
(10 to 100) kHz
100 kHz to 128 MHz
0.60 dB
1.2 dB
1.2 dB
0.74 dB
1.6 dB
0.52 dB
0.35 dB
0.51 dB
1.1 dB
0.51 dB
0.13 dB
0.33 dB
0.54 dB
1.1 dB
0.21 dB
0.11 dB
0.11 dB
0.43 dB
0.58 dB
0.032 dB
0.062 dB
0.079 dB
0.22 dB
0.38 dB
0.53 dB
0.031 dB
0.059 dB
0.079 dB
0.22 dB
0.33 dB
0.051 dB
0.058 dB
0.11 dB
0.26 dB
0.031 dB
0.059 dB
Fluke 96270A
leveled microwave
output
Fluke 96270A | ||
| 26 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 26 of 52
Parameter/Range
Frequency CMC2, 7 (±) Comments
Attenuation3, 5 – Measure
10 Hz to 128 MHz
(0 to 55) dB
(55 to 64) dB
(64 to 100) dB
(100 to 116) dB
0.044 dB
0.057 dB
0.17 dB
0.23 dB
Fluke 96270A,
Rohde &
Schwarz FSP
Amplitude Modulation3 –
Measure
Carrier: 150 kHz to 10 MHz
Rate: 50 Hz to 10 kHz
Rate: 20 Hz to 10 kHz
Carrier: 10 MHz to 1.3 GHz
Rate: 50 Hz to 50 kHz
Rate: 20 Hz to 100 kHz
Depth: (5 to 99) %
Depth: (5 to 99) %
Depth: (5 to 99) %
Depth: (5 to 99) %
2.7 %
3.8 %
1.9 %
3.8 %
HP 8901B
Amplitude Modulation3 – Generate
Carrier: 50 kHz to 4 GHz
Rate: 1 Hz to 100 kHz
Depth: (5 to 10) %
Depth: (10 to 99) %
1.6 %
3.9 %
Fluke 96270A
Frequency Modulation3 –Measure
Carrier: 150 kHz to 10 MHz
Rate: 20 Hz to 10 kHz
Carrier: 10 MHz to 1.3 GHz
Rate: 50 Hz to 100 kHz
Carrier: 10 MHz to 1.3 GHz
Rate: 20 Hz to 200 kHz
Deviation:
Up to 40 kHz
Deviation:
Up to 400 kHz
Deviation:
Up to 400 kHz
26 mHz/Hz + 310 mHz
15 mHz/Hz + 320 mHz
59 mHz/Hz + 290 mHz
HP 8901B
Frequency Modulation3 –Generate
Carrier: 9 MHz to 31.25 MHz
Rate: 1 Hz to 50 kHz
Rate: 50 Hz to 300 kHz
Carrier: 31.25 MHz to 125 MHz
Rate: 1 Hz to 50 kHz
Rate: 50 Hz to 300 kHz
Carrier: 125 MHz to 4 GHz
Rate: 1 Hz to 50 kHz
Rate: 50 Hz to 300 kHz
Deviation:
10 Hz to 300 kHz
Deviation:
10 Hz to 750 kHz
Deviation:
10 Hz to 4.8 MHz
11 mHz/Hz
60 mHz/Hz
11 mHz/Hz
36 mHz/Hz
11 mHz/Hz
36 mHz/Hz
Fluke 96270A | ||
| 27 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 27 of 52
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
Phase Modulation3 –
Measure
Carrier: 150 kHz to 10 MHz
Rate: 200 Hz to 10 kHz
Carrier: 10 MHz to 1.3 GHz
Rate: 200 Hz to 20 kHz
Deviation:
Up to 420 rad
Deviation:
Up to 420 rad
0.050 rad/rad + 0.067 rad
0.040 rad/rad + 0.067 rad
HP 8901B
Amplitude Modulation3 – Sine
Distortion
(10.0 to 89.0) %
50 kHz to 125 MHz
-40 dBc
HP 8903B
Phase Modulation3 –Generate
Carrier: 9 MHz to 4 GHz
Rate: 1 Hz to 50 kHz
Rate: 50 kHz to 300 kHz
Deviation:
Up to 1000 rad
0.011 rad/rad
0.036 rad/rad
Fluke 96270A
Total Harmonic Distortion3
47 Hz to 100 kHz
1.7 %
North Atlantic
PAV 2250A
VI. Mechanical
Parameter/Equipment
Range CMC2, 6 (±) Comments
Accelerometers3
Voltage Sensitivity –
Up to 1000 mV/g’s
50 Hz to 2 kHz
(2 to 10) kHz
(5 to 9) Hz
(10 to 99) Hz
100 Hz
(101 to 1999) Hz
(2 to 10) kHz
3.5 %
5.0 %
2.7 %
2.6 %
2.3 %
2.3 %
5.6 %
Modal Shop 9100D
Portable
Modal shop 9150D
shaker, digital
multimeter,
Function generator,
PCB signal
conditioner | to 420 rad |
| 28 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 28 of 52
Parameter/Equipment
Range CMC2, 6, 8 (±) Comments
Scales & Balances3 –
Linearity Only
(1 to 50) mg
(50 to 500) mg
(0.5 to 1) g
(1 to 5) g
(5 to 50) g
(50 to 100) g
(100 to 200) g
(200 to 2000) g
(2000 to 6000) g
(1.0 to 2.0) lbf
(2.0 to 5.0) lbf
(5.0 to 10.0) lbf
(10.0 to 20.0) lbf
(20.0 to 100.0) lbf
(100.0 to 200.0) lbf
0.017 mg
0.027 mg
0.055 mg
0.055 mg
0.16 mg
0.64 mg
0.77 mg
6.9 mg
0.14 g
1.1 x 10
-3 lbf
2.0 x 10-3 lbf
3.5 x 10-3 lbf
2.6 x 10-3 lbf
9.2 x 10-3 lbf
1.6 x 10-2 lbf
Class 1 weights
Reference Weights
Force – Measuring
Equipment3
(1 to 100) lb
(50 to 500) lb
(0.5 to 5) klb
(10 to 100) klb
0.052 %
0.090 %
0.16 %
0.049 %
Transducer techniques
MDB-10, Rice Lake
RL20000I-100, Rice
Lake RL2000I-T10-500
Interface RL9000TWM-
5K
Omega LCW-100K
Pneumatic Pressure –
Measuring Equipment
3
(-15 to 0) psig
Up to 5 psig
(5 to 15) psig
Up to 15 psig
(15 to 30) psig
Up to 45 psig
(45 to 90) psig
Up to 150 psig
(150 to 300) psig
Up to 500 psig
(500 to 1000) psig
Up to 1500 psig
(1500 to 3000) psig
3000 to 6000 psig
(6000 to 10 000) psig
0.0015 psi
0.001 psi
0.003 psi
0.0015 psi
0.003 psi
0.0046 psi
0.0091 psi
0.015 psi
0.030 psi
0.051 psi
0.10 psi
0.15 psi
0.31 psi
8.6 psi
9.5 psi
Fluke PM500
Fluke PPC4EX
Fluke PM500
Fluke 700P31 | ||
| 29 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 29 of 52
Parameter/Equipment
Range CMC2, 6, 8 (±) Comments
Tachometers3 – Optical
(30 to 250 000) rpm
12 µRPM/RPM + 0.6R
Fluke 5520A with LED
Torque – Measure3
(1 to 9) lbf·in
(5 to 50) lbf·in
(50 to 300) lbf·in
(10 to 150) lbf·ft
(150 to 600) lbf·ft
(600 to 1000) lbf·ft
2.1 %
0.64 %
0.38 %
0.35 %
0.31 %
7.1 lbf·ft
Delta Regis DRBT-10
Sturtevant Richmont
system 8 w/ transducers
Torque transducers w/
torque analyzer
Mass Flow (Gas) –
Measure
(0 to 0.5) slpm
(0.5 to 5) slpm
(5 to 50) slpm
(50 to 100) slpm
0.03 % + 0.0011 slpm
0.26 % + 0.03 slpm
0.26 % + 0.0002 slpm
0.13 % + 0.0002 slpm
Fluke Molbox1+ A700K,
Molbloc-L 3E4-VCR-V-
Q, Molbloc-L 5E3-VCR-
V-Q
V. Thermodynamics
Parameter/Equipment
Range CMC2, 8 (±) Comments
Humidity3 – Measuring
Equipment
(5 to 95) % RH
0.84 % RH
Rotronic HF53W-ID,
Rotronic HC2A probe
Temperature3 –
Measuring Equipment
Thermometers
Infrared
(-20 to 375) °C
(375 to 600) °C
(-15 to 0) °C
(0 to 50) °C
(50 to 100) °C
(100 to 120) °C
(35 to 100) °C
(100 to 200) °C
(200 to 350) °C
(350 to 500) °C
(500 to 1000) °C
(1000 to 1100) °C
(1100 to 1400) °C
(1400 to 1500) °C
0.088 °C
0.32 °C
0.96 °C
0.99 °C
1.0 °C
1.2 °C
0.82 °C
1.4 °C
2.0 °C
3.0 °C
7 °C
9 °C
10 °C
11 °C
WIKA CTP5000-450
probe
Fluke 4180 wavelength
(8 to 14) µm emissivity
0.95
Fluke 4181 wavelength
(8 to 14) µm emissivity
0.95
Mikron 335 wavelength
(0.65 to 1.8) µm emissivity
1.0 | 30 to 250000 rpm |
| 30 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 30 of 52
Parameter/Equipment
Range CMC2, 8 (±) Comments
Infrared – Measure3
(30 to 100) °C
(100 to 150) °C
(150 to 200) °C
(200 to 250) °C
(160 to 500) °C
(500 to 900) °C
(900 to 1300) °C
(1300 to 1650) °C
2.4 °C
3.5 °C
4.7 °C
6 °C
3 °C
4 °C
5 °C
5 °C
Infrared camera Fluke
VT04 wavelength (6.5 to
14) µm emissivity 0.01 to
1.0
Infrared camera Williamson
SW-22- 45C-FOV
wavelength (2.2) µm
emissivity 0.01 to 1.5
Temperature – Measure
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 420) °C
(420 to 550) °C
(550 to 660) °C
(660 to 700) °C
(700 to 800) °C
(800 to 900) °C
(900 to 1000) °C
0.084 °C
0.034 °C
0.037 °C
0.085 °C
0.12 °C
0.13 °C
3.8 °C
4.0 °C
4.0 °C
4.0 °C
Fluke 5615-12 probe, Fluke
1524 reference thermometer
Fluke 9144 w/ Fluke 5609
SPRT
Pyromation S-type probe
VI. Time & Frequency
Parameter/Equipment
Range CMC2, 8 (±) Comments
Frequency3 – Measuring
Equipment
Reference Oscillator
0.001 Hz to 10 kHz
10 kHz to 4 GHz
(4 to 26) GHz
10 MHz
0.091 µHz/Hz
0.060 µHz/Hz
0.058 µHz/Hz
0.12 mHz
Fluke 96270A
Trimble Thunderbolt E
Frequency3 –
Measure
1 mHz to 3 GHz
(3 to 20) GHz
30 nHz/Hz
46 nHz/Hz
Agilent 53132A
Agilent 53147A
Timers/Stopwatches3
Up to 24 hr
0.065 s/day
Timometer 4500
_____________________________________ | ||
| 31 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 31 of 52
SATELLITE
1338 Sadlier Circle Drive East
Indianapolis, IN 46239
Kenton Shepherd Phone: 260 471 6775
CALIBRATION
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted
to this laboratory to perform the following calibrations1, 11:
I. Acoustical Quantities
Parameter/Equipment
Range CMC2, 8 (±) Comments
Sound Level – Measuring
Equipment, Fixed Points3
94 dB
114 dB
0.28 dB
0.28 dB
Bruel & Kjaer 4231
II. Chemical
Parameter/Equipment
Range CMC2 (±) Comments
pH Meters, Fixed Points3
4 pH
7 pH
10 pH
0.017 pH
0.012 pH
0.019 pH
Standard pH
solutions
Conductivity Meters3
≈10 µS/cm
≈1413 µS/cm
≈10 mS/cm
≈100.9 mS/cm
4.4 µS/cm
9.8 µS/cm
0.15 mS/cm
2.2 mS/cm
Standard
conductivity
solutions | ||
| 32 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 32 of 52
III. Dimensional
Parameter/Equipment
Range CMC2, 6 (±) Comments
Calipers3 – Dial, Digital,
Vernier –
Length
Parallelism
Up to 18 in
(18 to 48) in
Up to 2 in
(290 + 7.3L) µin
(240 + 4.9L) µin
30 µin
Gage blocks
Depth Gauge3 – Dial,
Digital, Vernier
(0.001 to 48) in
(59 + 7.2L) µin
Gage blocks, surface plate
Height Gauges3
Up to 18 in
(18 to 36) in
(30 + 6.5L) µin
(16 + 7.3L) µin
Gage blocks
Indicators – Dial &
Digital
3
(0.000 01 to 2) in
(11 + 8.9L) µin
Gage blocks, surface plate,
Pratt & Whitney
Supermic
TM
Length Standards3
(Length only)
Up to 10 in
(3.2 + 1.0L) µin
P&W PC25
Measuring Tapes3,6
Up to 300 in
0.015 + (0.004S) in
Master ruler, measuring
tape fixture.
Micrometers3 –
OD
ID
Flatness
Parallelism
Up to 48 in
Up to 24 in
Up to 2 in
Up to 2 in
(30 + 13L) µin
(30 + 13L) µin
4.3 µin
4.3 µin
Gage blocks
Optical flat
Protractors3
Up to 90°
0.060°
Surface plate, sine bar,
gage blocks | to 300 in |
| 33 | ASME/ANSI B1.2- 1983; ASME/ANSI B1.3- 2007 | - | See scope document |
| 34 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 34 of 52
V. Electrical DC/Low Frequency
Parameter/Equipment
Range CMC2, 7 (±) Comments
DC Voltage3 – Measure
0 V Short
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 10) kV
(10 to 100) kV
(100 to 125) kV
(125 to 140) kV
0.62 µV/V
2.7 µV/V + 0.84 µV
2.0 µV/V + 5.7 µV
4.4 µV/V + 88 µV
1.5 µV/V + 2.0 mV
5.3 µV/V + 2.0 mV
0.35 mV/V + 35 mV
0.58 mV/V + 0.50 V
0.17 kV
0.29 kV
Copper short
HP 3458A Opt. 002
digital multimeter
Vitrek 4700 high voltage
multimeter, Vitrek HVL-
150 high voltage probe
DC Voltage3 – Generate
(0 to 220) mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
(0.1 to 1.0) kV
(1.0 to 4.0) kV
(4.0 to 9.0) kV
(9.0 to 25) kV
(25 to 50) kV
(50 to 60) kV
9.6 µV/V + 0.63 µV
4.3 µV/V + 4.4 µV
4.0 µV/V + 4.5 µV
4.1 µV/V + 4.9 µV
5.7 µV/V + 98 µV
7.8 µV/V + 660 µV
0.61 V
2.5 V
4.7 V
38 V
58 V
81 V
Fluke 5700A
HV Source monitored by
Vitric 4700
HV Source monitored.
by Vitrek 4700/HVL150
probe
DC Current3 –
Measure
(0 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
(10 to 1000) A
(1 to 2.8) kA
36 µA/A + 0.5 nA
31 µA/A + 5 nA
32 µA/A + 50 nA
52 µA/A + 0.5 µA
0.15 mA/A + 5uA
0.26 mA/A
4.2 mA/A + 0.5A
12 mA/A + 0.5A
HP 3458A opt. 002
digital multimeter
Y5020
LEM PR2000 current
clamp, HP 3458A opt.
002 digital multimeter | ||
| 35 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 35 of 52
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
DC Current3 – (cont)
Generate
Clamp Meters
(0 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(1.3 to 3) A
(3 to 11) A
(11 to 20.5) A
(20.5 to 1000) A
10 nA/A + 7.1 nA
8.7 nA/A + 13 nA
8.7 nA/A + 49 nA
1.1 nA/A + 0.84 µA
2.0 nA/A + 31 µA
400 µA/A + 1.5 mA
1 mA/A + 2.4 mA
1.1 mA/A + 2.4 mA
6.0 mA/A + 0.60 A
Fluke 5700A
Fluke 5520A w/ coil
Resistance3 – Generate
Fixed
0.000 333 3 Ω
0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
100Ω
1k Ω
10 kΩ
10 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
0 Ω
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
1.2 mΩ/Ω
0.58 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.12 mΩ/Ω
0.32 kΩ
0.56 MΩ
0.61 MΩ
0.12 GΩ
2.6 GΩ
47 µΩ
110 µΩ
110 µΩ
35 µΩ
43 µΩ
0.15 mΩ
0.28 mΩ
1.6 mΩ
2.9 mΩ
15 mΩ
29 mΩ
0.18 Ω
0.30 Ω
17 Ω
19 Ω
71 Ω
250 Ω
4.2 kΩ
9211A Guildline
Metrohm P4085 series
resistors
Fluke 5700A | ||
| 36 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 36 of 52
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Resistance3 – Measure
(0 to 10) Ω
(10 to 100) Ω
(100 to 1000) Ω
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 100) MΩ
100 MΩ to 1 GΩ
Up to 2 Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
(2 to 20) GΩ
29 µΩ/Ω + 0.58 mΩ
12 µΩ/Ω + 0.58 mΩ
12 µΩ/Ω + 5.8 mΩ
12 µΩ/Ω + 58 mΩ
18 µΩ/Ω + 2.3 Ω
58 µΩ/Ω + 0.12 kΩ
5.8 mΩ/Ω + 12 kΩ
5.8 mΩ/Ω + 12 kΩ
28 µΩ/Ω
25 µΩ/Ω
17 µΩ/Ω
14 µΩ/Ω
14 µΩ/Ω
14 µΩ/Ω
19 µΩ/Ω
28 µΩ/Ω
0.014 %
0.12 %
0.23 %
HP 3458A Opt. 002,
digital multimeter
Fluke 8508A
Resistance3 – Generate
(0 to 1) Ω
(1 to 1.9) Ω
(1.9 to 10) Ω
(10 to 19) Ω
(19 to 100) Ω
(100 to 190) Ω
(190 to 1000) Ω
(1000 to 1900) Ω
(1.9 to 10) kΩ
(10 to 19) kΩ
(19 to 100) kΩ
(100 to 190) kΩ
(0.19 to 1) MΩ
(1 to 1.9) MΩ
(1.9 to 100) MΩ
46 µΩ/Ω + 1.2 mΩ
46 µΩ/Ω + 1.2 mΩ
46 µΩ/Ω + 1.2 mΩ
34 µΩ/Ω + 1.8 mΩ
28 µΩ/Ω + 3.5 mΩ
28 µΩ/Ω + 3.5 mΩ
29 µΩ/Ω + 6.3 mΩ
27 µΩ/Ω + 4.0 mΩ
26 µΩ/Ω + 100 mΩ
27 µΩ/Ω + 40 mΩ
26 µΩ/Ω + 1 Ω
33 µΩ/Ω + 3.4 Ω
30 µΩ/Ω + 11 Ω
63 µΩ/Ω + 0.05 kΩ
0.52 mΩ/Ω + 10 kΩ
Fluke 5520A
Resistance3 – Current
Shunt
Up to 80 mΩ
(80 to 800) mΩ
(0.8 to 1000) Ω
320 µΩ/Ω + 1.3 nΩ
140 µΩ/Ω + 4.7 nΩ
81 µΩ/Ω + 16 µΩ
Fluke 5520A, HP
3458A Opt.002
digital multimeter | ||
| 37 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 37 of 52
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage3 – Generate
(0.005 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
(0.22 to 2.2) V
(2.2 to 22) V
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
0.022 % + 5.2 µV
0.011 % + 5.2 µV
0.011 % + 5.2 µV
0.038 % + 5.2 µV
0.087 % + 8.1 µV
0.12 % + 15 µV
0.17 % + 29 µV
0.36 % + 29 µV
0.022 % + 5.8µV
0.011 % + 5.8µV
0.011 % + 5.8µV
0.039 % + 5.9µV
0.088 % + 8.1µV
0.12 % + 16 µV
0.18 % + 29µV
0.34 % + 36 µV
0.022 % + 9.5 µv
0.011 % + 9.6 µv
0.011 % + 9.4 µV
0.018 % + 62 µV
0.058 % + 130 µV
0.11 % + 37 µV
0.18 % + 41 µV
0.37 % + 93 µV
0.016 % + 48 µV
0.074 % + 14 µV
0.075 % + 11 µV
29 µV/V + 0.70 mV
0.016 % + 0.38 mV
0.046 % + 0.15 mV
0.11 % + 0.42 mV
0.22 % + 1.0 mV
0.016 % + 0.38 mV
73 µV/V + 0.15 mV
75 µV/V + 0.12 mV
0.011 % + 0.82 mV
0.024 % + 0.47 mV
0.053 % + 1.7 mV
0.14 % + 5.0 mV
0.29 % + 1.0 mV
Fluke 5700A | ||
| 38 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 38 of 52
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Voltage3 – Generate (cont)
(22 to 220) V
(220 to 750) V
(750 to 1050) V
(1 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(0.5 to 1) MHz
(15 to 50) Hz
(0.05 to 1) kHz
(0.04 to 10) kHz
(10 to 33) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
(0.045 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(0.045 to 1) kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.17 % + 3.9 mV
80 µV/V + 1.6 mV
82 µV/V + 1.2 mV
0.023 % + 4.2 mV
0.53 % + 9.5 mV
0.17 % + 0.11 V
0.53 % + 0.11 V
1.3 % + 0.22 V
0.043 % + 19 mV
77 µV/V + 9.3 mV
29 µV/V
0.13 mV/V
99 µV/V + 19 µV
99 µV/V + 19 µV
9.3 µV/V + 250 µV
48 µV/V + 140 µV
0.045 % + 100 µV
0.22 % + 87 µV
0.012 % + 0.12 mV
0.012 % + 0.12 mV
13 µV/V + 1.8 mV
35 µV/V + 1.1 mV
0.045 % + 0.43 mV
0.26 % + 0.80 mV
0.017 % + 0.71 mV
0.017 % + 0.71 mV
0.027 % + 0.72 mV
0.040 % + 0.74 mV
0.10 % + 1.9 mV
0.28 % + 0.80 mV
0.021 % + 3.0 mV
0.022 % + 7.8 mV
0.024 % + 10 mV
0.019 % + 20 mV
0.22 % + 62 mV
0.033 % + 19 mV
0.030 % + 32 mV
0.028 % + 11 mV
0.31 % + 20 mV
0.23 % + 63 mV
Fluke 5700A | ||
| 39 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 39 of 52
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage3 – Generate
(cont)
(330 to 1020) V
(0.1 to 1.0) kV
(1.0 to 4.0) kV
(4.0 to 9.0) kV
(9.0 to 10) kV
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(50 to 60) Hz
(50 to 60) Hz
(50 to 60) Hz
(50 to 60) Hz
0.034 % + 19 mV
0.028 % + 20 mV
0.033 % + 32 mV
2.1 V
6.4 V
18 V
0.12 kV
Fluke 5520A
HV source monitored by
Vitrek 4700
HV source monitored by
Vitrek 4700 w/ HVL-150
probe
AC Voltage3 – Measure
10 mV
100 mV
1 V
10 V
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(1 to 2) MHz
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 1) MHz
(1 to 2) MHz
790 µV/V + 1.1 µV
98 µV/V + 9.0 µV
170 µV/V + 16 µV
320 µV/V + 32 µV
820 µV/V + 82 µV
10 mV/V + 1.1 mV
130 µV/V + 11 µV
98 µV/V + 9 µV
170 µV/V + 16 µV
320 µV/V + 32 µV
0.83 mV/V + 82 µV
3.1 mV/V + 0.31 mV
11 mV/V + 1.1 mV
16 mV/V + 1.5 mV
7.9 mV/V + 0.11 mV
4.1 mV/V + 90 µV
4.8 mV/V + 0.16 mV
4.4 mV/V + 0.32 mV
3.8 mV/V + 0.9 mV
8.1 mV/V + 3.1 mV
16 mV/V + 11 mV
20 mV/V + 15 mV
0.79 mV/V + 1.1 mV
0.41 mV/V + 0.9 mV
0.50 mV/V + 1.6 mV
0.55 mV/V + 3.2 mV
0.9 mV/V + 8.2 mV
3.2 mV/V + 31 mV
11 mV/V + 0.11 V
16 mV/V + 0.16 V
HP 3458 opt. 002 digital
multimeter | ||
| 40 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 40 of 52
Parameter/Range
Frequency CMC2, 7 (±) Comments
AC Voltage3 – Measure
(cont.)
100 V
700 V
(1 to 9) kV
(9 to 20) kV
(20 to 40) kV
(40 to 60) kV
(60.0 to 80) kV
(80.0 to 100.0) kV
(1 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
(10 to 40) Hz
(40 to 1000) Hz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(0.01 to 600) Hz
(30 to 200) Hz
(30 to 200) Hz
(30 to 200) Hz
(30 to 200) Hz
(30 to 200) Hz
1.1 mV/V + 24 mV
0.22 mV/V + 22 mV
0.22 mV/V + 22 mV
0.37 mV/V + 37 mV
1.3 mV/V + 0.13 V
4.1 mV/V + 0.41 V
16 mV/V + 1.6 V
0.45 mV/V + 37 mV
0.45 mV/V + 37 mV
1.4 mV/V + 42 mV
3.5 mV/V + 42 mV
3.5 mV/V + 42 mV
11 V
30 V
54 V
78 V
0.10 kV
0.13 kV
Vitrek 4700 high voltage
multimeter
Vitrek 4700 with HVL-
150 high voltage probe
AC Current3 – Measure
Up to 100 µA
(1 to 100) mA
(0.1 to 1) A
(1 to 20) A
(20 to 2800) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 1) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
(0.1 to 5) kHz
(5 to 20) kHz
(20 to 50) kHz
(2 to 10) kHz
3 Hz to 10 kHz
1 Hz to 10 kHz
1.9 mA/A + 0.56 µA
0.37 mA/A + 0.58 µA
91 µA/A + 0.58 µA
84 µA/A + 0.57 µA
4.7 mA/A + 24 µA
1.8 mA/A + 24 µA
0.70 mA/A + 24 µA
0.35 mA/A + 24 µA
0.70 mA/A + 24 µA
4.7 mA/A + 47 µA
6.4 mA/A + 170 µA
4.7 mA/A + 0.24 mA
1.9 mA/A + 0.24 mA
0.92 mA/A + 0.25 mA
2.1 mA/A + 0.25 mA
3.5 mA/A + 0.24 mA
12 mA/A + 0.47 mA
0.10 %
0.30 %
12 mA/A
HP 3458 opt. 002 digital
multimeter
Fluke Y5020
LEM PR2000 | ||
| 41 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 41 of 52
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current3 – Generate
(0.02 to 220) µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(20.5 to 150) A
Toroidal
Non-Toroidal
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
(0.04 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(0.02 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
(0.045 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
(45 to 100) Hz
(0.1 to 1) kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 440) Hz
45 to 65) Hz
(65 to 440) Hz
0.93 mA/A + 30 nA
0.49 mA/A + 25 nA
0.20 mA/A + 20 nA
0.83 mA/A + 50 nA
0.21 % + 0.1 µA
0.93 mA/A + 50 nA
0.49 mA/A + 40 nA
0.19 mA/A + 40 nA
0.82 mA/A + 50 nA
0.21 % + 1 µA
0.93 mA/A + 50 nA
0.49 mA/A + 40 nA
0.19 mA/A + 40 nA
0.81 mA/A + 50 nA
0.21 % + 1 µA
0.93 mA/A + 4 µA
0.49 mA/A + 4 µA
0.22 mA/A + 0.4 µA
0.82 mA/A + 50 nA
0.21 % + 1µA
0.87 mA/A + 40 µA
0.99 mA/A + 0.10 mA
1.2 % + 0.20 mA
0.21 % + 0.10 mA
0.76 mA/A + 0.10 mA
0.70 % + 1.0 mA
2.9 % + 5.0 mA
0.74 mA/A + 2.0 mA
0.12 % + 2.0 mA
3.5 % + 2.0 mA
0.15 % + 5.0 mA
0.18 % + 5.0 mA
3.5 % + 5.0 mA
0.41 mA/A
0.96 mA/A
8.7 mA/A
14 mA/A
Fluke 5700A
Fluke 5520A
Fluke 5520A,
5500A/coil | ||
| 42 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 42 of 52
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
AC Current3 –
Generate
(cont)
(150 to 1000) A
Toroidal
Non-Toroidal
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.41 mA/A
0.96 mA/A
7.9 mA/A
13 mA/A
Fluke 5520A,
5500A/coil
Parameter/Equipment
Range CMC2, 7 (±) Comments
DC Watts – Generate3
(0.010 89 to 10.89) mW
(10.890 to 99) mW
(99 to 336.6) W
(336.6 to 3060) W
(3060 to 20 910) W
0.033 %
0.14 %
0.14 %
0.12 %
0.07 %
Fluke 5520A
AC Watts – Generate3,
(45 to 65) Hz/PF=1
(0.1089 to 0.297) mW
(0.297 to 2.97) mW
(2.97 to 10.89) mW
(10.89 to 72.60) mW
(72.60 to 1485) mW
(1.485 to 6.765) W
(6.765 to 33.66) W
(33.66 to 336.6) W
(336.6 to 917.9) W
(917.9 to 2244) W
(2244 to 20 910) W
0.17 %
0.13 %
0.12 %
0.24 %
0.23 %
0.21 %
0.19 %
0.22 %
0.21 %
0.23 %
0.13 %
Fluke 5520A | ||
| 43 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 43 of 52
Parameter/Equipment
Range CMC2, 7 (±) Comments
Phase Angle3 –
Measure
(0 to 359.9999) °
Generate
(0 to 359.99) °
10 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 200) kHz
(10 to 65) Hz
(65 to 500) Hz
(0.5 to 1) kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.012°
0.017°
0.051°
0.11°
0.11°
0.26°
0.50°
2.5°
5.0°
10°
North Atlantic PAV
2250A
Fluke 5520A
Inductance3 –
Measure
Generate
Fixed points
Variable
(0.1 to 10) µH
(0.01 to 10) mH
0.01 to 100) mH
(0.1 to 10) H
(10 to 100) H
20 mH
100 mH
200 mH
2 H
(1 to 10) mH
(10 to 100) mH
(0.1 to 1) H
(1 to 10) H
0.022 µH
0.21 µH
0.02 H
6.4 H
0.61 H
0.012 mH
0.054 mH
0.12 mH
1.3 mH
9.5 µH
0.81 mH
0.011 H
0.2 H
HP 4284A
General radio 1482
series inductors
General radio 1490D
Dissipation Factor –
Measure (Df)3
1 pF to 100 µF
(0.0001 to 10) Df
3.5 % + 1 cts
Multi-frequency LCR
Meter
cts: Counts of LSD | 0 to 359.9999 ° |
| 44 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 44 of 52
Parameter/Equipment
Range CMC2, 7 (±) Comments
Capacitance3 –
Measure
Generate
(0 to 1) nF
(0.001 to 10) µF
(0.001 to 10) mF
(0.01 to 110) mF
(0.19 to 0.4) nF
(0.4 to 1.1) nF
(1.2 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.2 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.2 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 100) mF
1.1 pF
5.4 nF
0.011 mF
0.28 mF
0.26 % + 13 pF
0.56 % + 12 pF
0.27 % + 13 pF
0.29 % + 120 pF
0.27 % + 140 pF
0.27 % + 390 pF
0.27 % + 1.3 nF
0.27 % + 3.9 nF
0.25 % + 15 nF
0.26 % + 42 nF
0.38 % + 170 nF
0.45 % + 480 nF
0.50 % + 1.4 µF
0.44 % + 4.9 µF
0.26 % + 36 µF
0.78 % + 49 µF
0.83 % + 360 µF
1.1 % + 360 µF
HP 4284A
Fluke 5520A
Capacitance3 – Fixed
1 nF
2 nF
10 nF
100 nF
200 nF
1 µF
0.50 pF
1.1 pF
5.4 pF
7.4 pF
0.10 nF
0.19 nF
General radio 1409
series standard
capacitors | ||
| 45 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 45 of 52
Parameter/Equipment
Range CMC2, 12 (±) Comments
Thermocouple Indicating -
Simulation3
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(0 to 150) °C
(150 to 650) °C
(650 to 1000) °C
(1000 to 1800) °C
(1800 to 2316) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -30) °C
(-30 to 50) °C
(50 to 500) °C
(500 to 1200) °C
(-200 to -100) °C
(-100 to -30) °C
(-30 to 120) °C
(120 to 1050) °C
(1050 to 1371.1) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to -100) °C
(-100 to 0) °C
(0 to 400) °C
0.35 °C
0.28 °C
0.33 °C
0.52 °C
0.87 °C
0.58 °C
0.20 °C
0.18 °C
0.20 °C
0.26 °C
0.30 °C
0.29 °C
0.16 °C
0.23 °C
0.35 °C
0.19 °C
0.17 °C
0.15 °C
0.23 °C
0.42 °C
0.24 °C
0.21 °C
0.20 °C
0.28 °C
0.62 °C
0.41 °C
0.37 °C
0.43 °C
0.53 °C
0.41 °C
0.41 °C
0.49 °C
0.64 °C
0.26 °C
0.18 °C
0.15 °C
Fluke 5520A | ||
| 46 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 46 of 52
Parameter/Equipment
Range CMC2, 12 (±) Comments
RTD Simulation3
Cu427
Ni120
Pt 385, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
Pt 3916, 100 Ω
Pt 3926, 100 Ω
100 to 260 °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 600) °C
(600 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
0.34 °C
0.085 °C
0.084 °C
0.15 °C
0.090 °C
0.093 °C
0.11 °C
0.13 °C
0.14 °C
0.15 °C
0.25 °C
0.046 °C
0.055 °C
0.13 °C
0.14 °C
0.15 °C
0.17 °C
0.042 °C
0.051 °C
0.061 °C
0.081 °C
0.092 °C
0.12 °C
0.031 °C
0.041 °C
0.052 °C
0.062 °C
0.072 °C
0.23 °C
0.28 °C
0.058 °C
0.067 °C
0.075 °C
0.093 °C
0.11 °C
0.11 °C
0.12 °C
0.24 °C
0.066 °C
0.083 °C
0.11 °C
0.12 °C
0.14 °C
Fluke 5520A | ||
| 47 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 47 of 52
Parameter/Equipment
Range CMC2 (±) Comments
Oscilloscopes –
Amplitude – DC Signal3
50 Ω Load
1 MΩ Load
Amplitude – Square
Wave
50 Ω Load
1 MΩ Load
(0 to 6) V
(0 to 130) V
1 mV
p-p to 6.6 Vp-p;
10 Hz to 10 kHz
1 mV
p-p to 130 Vp-p;
10 Hz to 10 kHz
29 mV/V + 0.58 mV
590 µV/V + 75 µV
29 mV
p-p/Vp-p + 75 µVp-p
280 µV
p-p/Vp-p + 75 µVp-p
5520A-SC1100
multifunction
calibrator w/
oscilloscope opt
Oscilloscopes – Rise Time
0.001 to 2 MHz
2 to 10 MHz
(200 to 300) ps
(250 to 350) ps
120 ps
140 ps
5520A-SC1100
multifunction
calibrator w/
oscilloscope opt
Oscilloscopes –
Bandwidth3
5 mV to 5.5 Vp-p
4 mV to 3.5 V
p-p
Leveled Sine Wave –
Frequency
Time Marker
50 kHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(600 to 1100) MHz
50 kHz to 1.1 GHz
2 ns to 20 ms
50 ms to 5 s
58 mVp-p/Vp-p + 470 µVp-p
58 mVp-p/Vp-p + 470 µVp-p
70 mVp-p/Vp-p + 470 µVp-p
120 mVp-p/Vp-p + 470 µVp-p
140 mVp-p/Vp-p + 470 µVp-p
0.58 kHz
2.9 µs/s + 0.15 ps
1.2 ms/s + 58 µs
5520A-SC1100
multifunction
calibrator w/
oscilloscope opt | ||
| 48 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 48 of 52
Parameter/Equipment
Range CMC2 (±) Comments
Oscilloscopes –
Wave Functions -
Square, Sine, &Triangle3
50 Ω Load
1 MΩ Load
Pulse Characteristics3 –
Pulse Width
Pulse Period
Rise Time – Generate
1.8 mV
p-p to 2.5 Vp-p.
10 Hz to 10 kHz
1.8 mVp-p to 55 Vp-p.
10 Hz to 10 kHz
(4 to 500) ns
200 ns to 20 ms
1 kHz to 2 MHz
(200 to 300) ps
3 to 10 MHz
(200 to 350) ps
35 mV
p-p/Vp-p + 120 µVp-p
35 mVp-p/Vp-p + 120 µVp-p
2.6 ns
150 ps
120 ps
120 ps
5520A-SC1100
multifunction
calibrator w/
oscilloscope opt.
IV. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 7 (±)
Comments
Total Harmonic
Distortion3
47 Hz to 100 kHz
1.7 %
North Atlantic PAV
2250A
VI. Mechanical
Parameter/Equipment
Frequency CMC2, 6 (±) Comments
Accelerometers3
Voltage Sensitivity
(up to 1000) mv/g’s
50 Hz to 2 kHz
(2 to 10) kHz
3.5 %
5.0 %
Modal Shop 9100D
Portable | ||
| 49 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 49 of 52
Parameter/Range
Range
CMC2, 7 (±)
Comments
Scales & Balances3 –
Linearity Only
(1.0 to 2.0) lbf
(2.0 to 5.0) lbf
(5.0 to 10.0) lbf
(10.0 to 20.0) lbf
(20.0 to 100.0) lbf
(100.0 to 200.0) lbf
(1 to 50) mg
(50 to 500) mg
(0.5 to 1) g
(1 to 5) g
(5 to 50) g
(50 to 100) g
(100 to 200) g
(200 to 2000) g
(2000 to 6000) g
1.1 x 10-3 lbf
2.0 x 10-3 lbf
3.5 x 10-3 lbf
2.6 x 10-3 lbf
9.2 x 10-3 lbf
1.6 x 10-2 lbf
0.017 mg
0.027 mg
0.055 mg
0.055 mg
0.16 mg
0.64 mg
0.77 mg
6.9 mg
0.14 g
Reference Weights
Class 1 weights
Force – Measuring
Equipment3
(1 to 100) lb
0.052 %
Class F weights
Pneumatic Pressure –
Measuring Equipment
3
Compressed Air3
Pressure
Up to 15 psi
(15 to 30) psi
Up to 45 psi
(45 to 90) psi
Up to 150 psi
(150 to 300) psi
Up to 500 psi
(500 to 1000) psi
Up to 1500 psi
(1500 to 3000) psi
(3000 to 6000) psi
(6000 to 10 000) psi
0.0015 psi
0.003 psi
0.0046 psi
0.0091 psi
0.015 psi
0.030 psi
0.051 psi
0.10 psi
0.15 psi
0.31 psi
8.6 psi
9.5 psi
Fluke 6270
Fluke PM500
Fluke 700P31 | ||
| 50 | DOC-00196 | - | 30 to 250000 rpm |
| 51 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 51 of 52
Parameter/Equipment
Range CMC2, 8 (±) Comments
Infrared – Measure3
(30 to 100) °C
(100 to 150) °C
(150 to 200) °C
(200 to 250) °C
(160 to 500) °C
(500 to 900) °C
(900 to 1300) °C
(1300 to 1650) °C
2.4 °C
3.5 °C
4.7 °C
6 °C
3 °C
4 °C
5 °C
5 °C
Infrared camera Fluke
VT04 wavelength (6.5 to
14) µm emissivity 0.01 to
1.0
Infrared camera Williamson
SW-22- 45C-FOV
wavelength (2.2) µm
emissivity 0.01 to 1.5
Temperature – Measure
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 420) °C
(420 to 500) °C
0.084 °C
0.031 °C
0.033 °C
0.066 °C
0.078 °C
Fluke 5615-9 probe, Fluke
1524 reference thermometer
Burns 12005
VI. Time & Frequency
Parameter/Equipment
Range CMC2, 8 (±) Comments
Frequency3 –
Measure
1 mHz to 3 GHz
(3 to 20) GHz
30 nHz/Hz
46 nHz/Hz
Agilent 53132A
Agilent 53147A
Timers/Stopwatches3
Up to 24 hr.
0.065 s/day
Timometer 4500
__________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 52 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 52 of 52
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 Specifications are typical below 10 MHz.
5 Relative to +16 dBm output.
6 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches;
R is instrument resolution; D is diagonal length; S is each segment greater than the first 36 inch segment;
percentages are percentage of reading, unless otherwise indicated.
7 The measurands stated are generated using the indicated instrument (see Comments). This capability is
suitable for the calibration of the devices intended to measure the measurand in the ranges
indicated. CMC are expressed as either a specific value that covers the full range or as a fraction of the
reading plus a fixed floor specification.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
9 Adjustable thread rings are set to applicable specifications using calibrated master set plug gages.
10 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration.
11 This scope meets A2LA’s P112 Flexible Scope Policy.
12 Simulation is measuring equipment and measure. | ||
| 53 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Summit City Precision MachiningFort Wayne, IN · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Tri-State Instrument ServiceFort Wayne, IN · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Richard J. Bagan, Inc. D.B.A. Montech USAColumbia City, IN · ~31 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Toledo Integrated Systems / Toledo TransducersMaumee, OH · ~135 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Instrument Calibration SolutionsClayton, OH · ~150 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.