United States

ENI Labs

3120 Independence Dr., 46808, Fort Wayne, IN, United States

Visit website
A2LA 2147.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
53
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 53 scope lines.

A2LA certificate 2147.01 · 53 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 2 of 52 III. Dimensional Parameter/Equipment Range CMC2, 6 (±) Comments Calipers3 – Dial, Digital, Vernier – Length Parallelism Up to 18 in (18 to 48) in Up to 2 in (290 + 7.3L) µin (240 + 4.9L) µin 30 µin Gage blocks Depth Gauge3 – Dial, Digital, Vernier (0.001 to 48) in (59 + 7.2L) µin Gage blocks, surface plate Gage Blocks – Flatness Up to 10 in Up to 4 in 4 to 24 in Up to 2 in (5.0 + 0.95L) µin (5.4 + 0.75L) µin (5.0 + 0.95L) µin 2.5 µin Pratt & Whitney Labmaster TM LMU-175, gauge blocks, optical flat Mahr comparator, gauge blocks, optical flat Height Gauges3 Up to 18 in (18 to 36) in (30 + 6.5L) µin (16 + 7.3L) µin Gage blocks Indicators – Dial & Digital3 (0.000 01 to 2) in (11 + 8.9L) µin Gage blocks, surface plate, Pratt&Whitney SupermicTM Length Standards3 (Length only) Up to 10 in (10 to 20) in (20 to 96) in (3.2 + 1.0L) µin (7.8 + 15L) µin (45 + 17L) µin Pratt&Whitney LabmasterTM LMU-175, micrometer head, gage blocks, P&W PC25 Measuring Rule3 Up to 48 in (300 + 4.0L) µin Hexagon Optiv Classic 321 Measuring Tapes3,6 Up to 300 in 0.015 + (0.004S) in Master ruler, measuring tape fixture Micrometers3 – OD ID Flatness Parallelism Up to 48 in Up to 24 in Up to 2 in Up to 2 in (30 + 13L) µin (30 + 13L) µin 4.3 µin 4.3 µin Gage blocks Optical flat
to 18 in
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 3 of 52 Parameter/Equipment Range CMC2, 6 (±) Comments Optical Comparators3 – Angularity Linearity X-Y Magnification (0 to 180)° Up to 12 in Up to 50X 0.79 arc min 160 µin 0.0035 in Sine bar, gage blocks Glass scale Magnification master, pin gauge Plain Gage3 – Pins & Plugs Rings Up to 1 in (1 to 10) in (10 to 20) in Up to 1 in (1 to 10) in (7.8 + 9.1L) µin (2.9 + 14L) µin (11 + 13L) µin (6.3 + 12L) µin (2.4 + 16L) µin Pratt & Whitney LabmasterTM LMU-175, gage blocks, P&W PC25 Protractors3 Up to 90° 0.060° Surface plate, sine bar, gage blocks Sine Bars – Length Parallelism (5 to 10) in (5 to 10) in (76 + 4.6L) µin 29 µin Hexagon Optiv Classic 321, Hexagon Global S Chrome Electronic gauge head Surface Plates3 – Flatness Repeatability Up to 170 in diagonal (-0.002 to 0.002) in (7.1 √D) µin 28 µin Mahr Federal EMD-832-W3 electronic level Rahn Repeat-O-Meter Thickness Gauge3 (Feeler Type) (0.001 to 1) in (8.6 + 30L) µin Pratt & Whitney LabmasterTM LMU-175 Thickness Gauge3 (Ultrasonic) (0.001 to 8) in 590 µin Gage blocks
4ASME/ANSI B1.2-1983; ASME/ANSI B1.3-2007-to 4 in
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 5 of 52 V. Electrical DC/Low Frequency Parameter/Equipment Range CMC2, 7 (±) Comments DC Voltage3 – Generate Fixed point 10 V 0.5 µV/V Fluke 732B DC Voltage3 – Measure 0 V Short (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 10) kV (10 to 100) kV (100 to 125) kV (125 to 140) kV 0.62 µV/V 2.7 µV/V + 0.84 µV 2.0 µV/V + 5.7 µV 4.4 µV/V + 88 µV 1.5 µV/V + 2.0 mV 5.3 µV/V + 2.0 mV 0.35 mV/V + 35 mV 0.58 mV/V + 0.50 V 0.17 kV 0.29 kV Copper short HP 3458A Opt. 002 digital multimeter Vitrek 4700 high voltage multimeter, Vitrek HVL- 150 high voltage probe DC Voltage3 – Generate (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V (0.1 to 1.0) kV (1.0 to 4.0) kV (4.0 to 9.0) kV (9.0 to 25) kV (25 to 50) kV (50 to 60) kV 9.6 µV/V + 0.63 µV 4.3 µV/V + 4.4 µV 4.0 µV/V + 4.5 µV 4.1 µV/V + 4.9 µV 5.7 µV/V + 98 µV 7.8 µV/V + 660 µV 0.61 V 2.5 V 4.7 V 38 V 58 V 81 V Fluke 5700A HV Source monitored by Vitric 4700 HV Source monitored by Vitrek 4700/HVL150 probe
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 6 of 52 Parameter/Equipment Range CMC2, 7 (±) Comments DC Current3 – Measure Generate Clamp Meters (0 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 10) A (10 to 1000) A (1 to 2.8) kA 10 µA 100 µA 1 mA 10 mA 20 mA 200 mA 2 A 20 A (0 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (20.5 to 1000) A 36 µA/A + 0.5 nA 31 µA/A + 5 nA 32 µA/A + 50 nA 52 µA/A + 0.5 µA 0.15 mA/A + 5uA 0.26 mA/A 4.2 mA/A + 0.5A 12 mA/A + 0.5A 12 µA/A 12 µA/A 24 µA/A 24 µA/A 24 µA 24 µA 26 µA 32 µA 10 nA/A + 7.1 nA 8.7 nA/A + 13 nA 8.7 nA/A + 49 nA 1.1 nA/A + 0.84 µA 2.0 nA/A + 31 µA 400 µA/A + 1.5 mA 1 mA/A + 2.4 mA 1.1 mA/A + 2.4 mA 6.0 mA/A + 0.60 A HP 3458A opt. 002 digital multimeter Y5020 LEM PR2000 current clamp, HP 3458A opt. 002 digital multimeter HP 3458A opt. 002, Fluke A40B series current shunts Fluke 5700A Fluke 5520A Fluke 5520A w/ coil
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 7 of 52 Parameter/Equipment Range CMC2, 7 (±) Comments Resistance3 – Generate Fixed 0.000 333 3 Ω 0.001 Ω 0.01 Ω 0.1 Ω 1 Ω 10 Ω 100Ω 1k Ω 10 kΩ 10 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 1.2 mΩ/Ω 0.58 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.32 kΩ 0.56 MΩ 0.61 MΩ 0.12 GΩ 2.6 GΩ 47 µΩ 110 µΩ 110 µΩ 35 µΩ 43 µΩ 0.15 mΩ 0.28 mΩ 1.6 mΩ 2.9 mΩ 15 mΩ 29 mΩ 0.18 Ω 0.30 Ω 17 Ω 19 Ω 71 Ω 250 Ω 4.2 kΩ 9211A Guildline Metrohm P4085 series resistors Fluke 5720A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 8 of 52 Parameter/Equipment Range CMC2, 7 (±) Comments Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω (100 to 1000) Ω (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 100) MΩ 100 MΩ to 1 GΩ Up to 2 Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ (2 to 20) GΩ 29 µΩ/Ω + 0.58 mΩ 12 µΩ/Ω + 0.58 mΩ 12 µΩ/Ω + 5.8 mΩ 12 µΩ/Ω + 58 mΩ 18 µΩ/Ω + 2.3 Ω 58 µΩ/Ω + 0.12 kΩ 5.8 mΩ/Ω + 12 kΩ 5.8 mΩ/Ω + 12 kΩ 28 µΩ/Ω 25 µΩ/Ω 17 µΩ/Ω 14 µΩ/Ω 14 µΩ/Ω 14 µΩ/Ω 19 µΩ/Ω 28 µΩ/Ω 0.014 % 0.12 % 0.23 % HP 3458A Opt. 002, digital multimeter Fluke 8508A Resistance3 – Generate (0 to 1) Ω (1 to 1.9) Ω (1.9 to 10) Ω (10 to 19) Ω (19 to 100) Ω (100 to 190) Ω (190 to 1000) Ω (1000 to 1900) Ω (1.9 to 10) kΩ (10 to 19) kΩ (19 to 100) kΩ (100 to 190) kΩ (0.19 to 1) MΩ (1 to 1.9) MΩ (1.9 to 100) MΩ 46 µΩ/Ω + 1.2 mΩ 46 µΩ/Ω + 1.2 mΩ 46 µΩ/Ω + 1.2 mΩ 34 µΩ/Ω + 1.8 mΩ 28 µΩ/Ω + 3.5 mΩ 28 µΩ/Ω + 3.5 mΩ 29 µΩ/Ω + 6.3 mΩ 27 µΩ/Ω + 4.0 mΩ 26 µΩ/Ω + 100 mΩ 27 µΩ/Ω + 40 mΩ 26 µΩ/Ω + 1 Ω 33 µΩ/Ω + 3.4 Ω 30 µΩ/Ω + 11 Ω 63 µΩ/Ω + 0.05 kΩ 0.52 mΩ/Ω + 10 kΩ Fluke 5520A Resistance3 – Current Shunt Up to 80 mΩ (80 to 800) mΩ (0.8 to 1000) Ω 320 µΩ/Ω + 1.3 nΩ 140 µΩ/Ω + 4.7 nΩ 81 µΩ/Ω + 16 µΩ Fluke 5520A, HP 3458A Opt.002 digital multimeter
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 9 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Measure (0 to 2.2) mV (2.2 to 7) mV (7 to 22) mV (22 to 70) mV (70 to 220) mV (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 0.43 mV/V + 1.5 µV 0.25 mV/V + 1.5 µV 0.25 mV/V + 1.5 µV 0.46 mV/V + 2.3 µV 0.69 mV/V + 2.9 µV 1.4 mV/V + 4.6 µV 1.5 mV/V + 9.2 µV 2.7 mV/V + 9.2 µV 0.22 mV/V + 1.5 µV 0.13 mV/V + 1.5 µV 0.13 mV/V + 1.5 µV 0.24 mV/V + 2.3 µV 0.36 mV/V + 2.9 µV 0.95 mV/V + 4.6 µV 1.0 µV/V + 9.2 µV 2.0 mV/V + 9.2 µV 0.15 mV/V + 1.8 µV 78 µV/V + 1.8 µV 78 µV/V + 1.8 µV 0.14 mV/V + 3.1 µV 0.24 mV/V + 5.9 µV 0.63 mV/V + 4.7 µV 0.82 mV/V + 9.3 µV 1.3 mV/V + 9.3 µV 99 µV/V + 1.9 µV 45 µ/V + 1.9 µV 45 µV/V + 1.9 µV 70 µV/V + 4.1 µV 0.14 mV/V + 9.8 µV 0.31 mV/V + 5.0 µV 0.45 mV/V + 9.5 µV 1.2 mV/V + 9.6 µV 15 µV/V + 77 µV 3.6 µV/V + 65 µV 3.6 µV/V + 65 µV 6.6 µV/V + 85 µV 7.8 µV/V + 0.15 mV 24 µV/V + 0.28 mV 59 µV/V + 0.28 mV 0.44 mV/V + 0.28 mV Fluke 5790A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 10 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Measure (cont) (220 to 700) mV (0.7 to 2.2) V (2.2 to 7) V (7 to 22) V (22 to 70) V (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 12 µV/V + 0.17 mV 3.4 µV/V + 83 µV 3.4 µV/V + 84 µV 24 µV/V + 36 µV 39 µV/V + 49 µV 44 µV/V + 0.34 mV 92 µV/V + 0.35 mV 0.68 µV/V + 0.36 mV 28 µV/V + 0.22 mV 15 µV/V + 45 µV 15 µV/V + 45 µV 52 µV/V + 16 µV 83 µV/V + 26 µV 0.22 mV/V + 50 µV 0.13 mV/V + 1.7 mV 0.89 mV/V + 1.5 mV 70 µ/V + 80 µV 25 µ/V + 59 µV 25 µV/V + 59 µV 49 µV/V + 59 µV 87 µV/V + 52 µV 0.23 mV/V + 40 µV 0.45 mV/V + 0.19 mV 1.3 mV/V + 0.43 mV 76 µV/V + 0.12 mV 34 µV/V + 0.10 mV 34 µV/V + 0.10 mV 62 µV/V + 0.10 mV 100 µV/V + 0.30 mV 0.20 mV/V + 0.86 mV 0.45 mV/V + 0.75 mV 1.4 mV/V + 0.58 mV 75 µV/V + 0.51 mV 30 µV/V + 0.64 mV 30 µV/V + 0.64 mV 74 µV/V + 0.51 mV 100 µV/V + 1.1 mV 0.21 vmV/V + 2.8 mV 0.57 mV/V + 1.0 mV Fluke 5790A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 11 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Measure (cont) (70 to 220) V (220 to 700) V (700 to 1000) V (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz 80 µV/V + 0.51 mV 35 µV/V + 0.64 mV 35 µV/V + 0.64 mV 78 µV/V + 0.51 mV 0.11 mV/V + 1.1 mV 0.23 mV/V + 2.8 mV 0.58 mV/V + 1.0 mV 0.11 mV/V + 4.2 mV 43 µV/V + 3.4 mV 43 µV/V + 3.4 mV 90 µV/V + 64 mV 0.31 mV/V + 0.27 V 0.11 mV/V + 4.2 mV 44 µV/V + 3.4 mV 44 µV/V + 3.4 mV 0.11 mV/V + 64 mV 0.37 mV/V + 0.27 V Fluke 5790A AC Voltage – Wideband Measure (0 to 2.2) mV (2.2 to 7) mV (7 to 22) mV (22 to 70) mV (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz 7.9 mV/V + 1.9 µV 7.5 mV/V + 1.9 µV 7.5 mV/V + 1.9 µV 7.5 mV/V + 1.9 µV 7.7 mV/V + 3.0 µV 7.7 mV/V + 2.6 µV 7.2 mV/V + 2.6 µV 7.2 mV/V + 2.6 µV 7.2 mV/V + 2.6 µV 7.4 mV/V + 3.7 µV 7.4 mV/V + 4.9 µV 6.9 mV/V + 4.9 µV 6.9 mV/V + 4.9 µV 6.9 mV/V + 4.9 µV 7.0 mV/V + 6.6 µV 7.4 mV/V + 6.1 µV 6.8 mV/V + 6.1 µV 6.8 mV/V + 6.1 µV 6.8 mV/V + 6.1 µV 6.7 mV/V + 6.1 µV Fluke 5790A w/ wideband opt.
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 12 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage – Wideband Measure (cont.) (70 to 220) mV (220 to 700) mV (0.7 to 2.2) V (2.2 to 7) V (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz (10 to 30) Hz (30 to 120) Hz (0.12 to 1.2) kHz (1.2 to 120) kHz (120 to 500) kHz 7.0 mV/V + 35 µV 6.4 mV/V + 35 µV 6.4 mV/V + 35 µV 6.4 mV/V + 35 µV 6.4 mV/V + 35 µV 5.8 mV/V + 93 µV 5.1 mV/V + 93 µV 5.1 mV/V + 93 µV 5.1 mV/V + 93 µV 5.1 mV/V + 93 µV 5.7 mV/V + 0.35 mV 5.0 mV/V + 0.35 mV 5.0 mV/V + 0.35 mV 5.0 mV/V + 0.35 mV 5.0 mV/V + 0.35 mV 5.2 mV/V + 0.49 mV 4.4 mV/V + 0.49 mV 4.4 mV/V + 0.49 mV 4.4 mV/V + 0.49 mV 4.4 mV/V + 0.49 mV Fluke 5790A w/ wideband opt. AC Voltage3 – Generate (0.005 to 2.2) mV (2.2 to 220) mV (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 0.022 % + 5.2 µV 0.011 % + 5.2 µV 0.011 % + 5.2 µV 0.038 % + 5.2 µV 0.087 % + 8.1 µV 0.12 % + 15 µV 0.17 % + 29 µV 0.36 % + 29 µV 0.022 % + 9.5 µv 0.011 % + 9.6 µv 0.011 % + 9.4 µV 0.018 % + 62 µV 0.058 % + 130 µV 0.11 % + 37 µV 0.18 % + 41 µV 0.37 % + 93 µV Fluke 5700A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 13 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate (cont) (0.22 to 2.2) V (2.2 to 22) V (22 to 220) V (220 to 750) V (220 to 750) V (750 to 1050) V (1 to 33) mV (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (15 to 50) Hz (0.05 to 1) kHz (0.03 to 10) kHz (10 to 33) kHz (33 to 100) kHz (0.04 to 10) kHz (10 to 33) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.016 % + 48 µV 0.074 % + 14 µV 0.075 % + 11 µV 29 µV/V + 0.70 mV 0.016 % + 0.38 mV 0.046 % + 0.15 mV 0.11 % + 0.42 mV 0.22 % + 1.0 mV 0.016 % + 0.38 mV 73 µV/V + 0.15 mV 75 µV/V + 0.12 mV 0.011 % + 0.82 mV 0.024 % + 0.47 mV 0.053 % + 1.7 mV 0.14 % + 5.0 mV 0.29 % + 1.0 mV 0.17 % + 3.9 mV 80 µV/V + 1.6 mV 82 µV/V + 1.2 mV 0.023 % + 4.2 mV 0.53 % + 9.5 mV 0.17 % + 0.11 V 0.53 % + 0.11 V 1.3 % + 0.22 V 0.043 % + 19 mV 77 µV/V + 9.3 mV 29 µV/V 0.13 mV/V 0.58 mV/V 29 µV/V 0.13 mV/V 99 µV/V + 19 µV 99 µV/V + 19 µV 9.3 µV/V + 250 µV 48 µV/V + 140 µV 0.045 % + 100 µV 0.22 % + 87 µV Fluke 5700A Wavetek 4808 Monitored with Fluke5790A Fluke 5520A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 14 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate (cont) (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (0.1 to 1.0) kV (1.0 to 4.0) kV (4.0 to 9.0) kV (9.0 to 10) kV (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.045 to 1) kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (50 to 60) Hz (50 to 60) Hz (50 to 60) Hz (50 to 60) Hz 0.012 % + 0.12 mV 0.012 % + 0.12 mV 13 µV/V + 1.8 mV 35 µV/V + 1.1 mV 0.045 % + 0.43 mV 0.26 % + 0.80 mV 0.017 % + 0.71 mV 0.017 % + 0.71 mV 0.027 % + 0.72 mV 0.040 % + 0.74 mV 0.10 % + 1.9 mV 0.28 % + 0.80 mV 0.021 % + 3.0 mV 0.022 % + 7.8 mV 0.024 % + 10 mV 0.019 % + 20 mV 0.22 % + 62 mV 0.033 % + 19 mV 0.030 % + 32 mV 0.028 % + 11 mV 0.31 % + 20 mV 0.23 % + 63 mV 0.034 % + 19 mV 0.028 % + 20 mV 0.033 % + 32 mV 2.1 V 6.4 V 18 V 0.12 kV Fluke 5520A HV source monitored by Vitrek 4700 HV source monitored by Vitrek 4700 w/ HVL-150 probe AC Voltage3 – Measure 10 mV (10 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 340 µV/V + 3.7 µV 230 µV/V + 1.4 µV 340 µV/V + 1.4 µV 1.2 mV/V + 1.6 µV 5.8 mV/V + 1.5 µV 47 mV/V + 2.7 µV HP 3458A
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 15 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Measure (cont.) 100 mV 1 V 10 V 100 V 700 V (1 to 10) kV (10 to 75) kV (60.0 to 80) kV (80.0 to 100.0) kV (10 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (10 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (10 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 1) MHz (1 to 2) MHz (10 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (10 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.01 to 600) Hz (0.01 to 600) Hz (50 to 60) Hz (50 to 60) Hz 56 µV/V + 110 µV 73 µV/V + 38 µV 160 µV/V + 35 µV 110 µV/V + 690 µV 0.68 mV/V + 0.33 mV 3.3 mV/V + 0.27 mV 12 mV/V + 97 µV 17 mV/V + 420 µV 56 µV/V + 1.1 mV 65 µV/V + 0.46 mV 0.16 mV/V + 0.35 mV 0.32 mV/V + 0.69 mV 0.92 mV/V + 0.38 mV 3.5 mV/V + 1.6 mV 12 mV/V + 0.97 mV 17 mV/V + 4.3 mV 0.21 mV/V + 7.3 mV 0.23 mV/V + 3.4 mV 0.23 mV/V + 3.3 mV 0.41 mV/V + 3.0 mV 1.4 mV/V + 3.4 mV 4.6 mV/V + 13 mV 17 mV/V + 22 mV 17 mV/V + 22 mV 0.44 mV/V + 54 mV 0.45 mV/ + 30 mV 0.64 mV/V + 34 mV 1.3 mV/V + 40 mV 3.6 mV/V + 20 mV 4.1 mV/V + 0.7 V 18 mV/V + 0.8 V 0.45 mV/V + 37 mV 0.45 mV/V + 37 mV 1.4 mV/V + 42 mV 3.5 mV/V + 42 mV 3.5 mV/V + 42 mV 1.4 mV/V + 0.12 V 1.1 mV/V + 0.77 V 0.49 kV 0.59 kV Vitrek 4700 high voltage multimeter Vitrek 4700 with HVL-150 high voltage probe
16--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 16 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current3 – Measure Up to 100 µA (1 to 100) mA (0.1 to 1) A (1 to 20) A (20 to 2800) A 10 µA 100 µA 1 mA 10 mA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 1) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (2 to 10) kHz 3 Hz to 10 kHz 1 Hz to 10 kHz (0.01 to 1) kHz (1 to 10) kHz (10 to 30) kHz (30 to 100) kHz (0.01 to 1) kHz (1 to 10) kHz (10 to 30) kHz (30 to 100) kHz (0.01 to 1) kHz (1 to 10) kHz (10 to 30) kHz (30 to 100) kHz (0.01 to 1) kHz (1 to 10) kHz (10 to 30) kHz (30 to 100) kHz 1.9 mA/A + 0.56 µA 0.37 mA/A + 0.58 µA 91 µA/A + 0.58 µA 84 µA/A + 0.57 µA 4.7 mA/A + 24 µA 1.8 mA/A + 24 µA 0.70 mA/A + 24 µA 0.35 mA/A + 24 µA 0.70 mA/A + 24 µA 4.7 mA/A + 47 µA 6.4 mA/A + 170 µA 4.7 mA/A + 0.24 mA 1.9 mA/A + 0.24 mA 0.92 mA/A + 0.25 mA 1.1 mA/A + 0.25 mA 3.5 mA/A + 0.24 mA 12 mA/A + 0.47 mA 0.10 % 0.30 % 12 mA/A 1.2 µA/A 1.1 µA/A 1.1 µA/A 1.9 µA/A 6.8 µA/A 9.0 µA/A 9.1 µA/A 18 µA/A 68 µA/A 90 µA/A 91 µA/A 0.18 mA/A 37 µA/A 37 µA/A 39 µA/A 59 µA/A HP 3458 opt. 002 digital multimeter Fluke 8508A LEM PR2000 current clamp, HP 3458A opt. 002 digital multimeter Fluke A40B series shunts, Fluke 5790
to 100 µA
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 17 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current3 – Measure (cont) 20 mA 200 mA 2 A 20 A (0.01 to 1) kHz (1 to 10) kHz (10 to 30) kHz (30 to 100) kHz (0.01 to 1) kHz (1 to 10) kHz (10 to 30) kHz (30 to 100) kHz (0.01 to 1) kHz (1 to 10) kHz (10 to 30) kHz (30 to 100) kHz (0.01 to 1) kHz (1 to 10) kHz (10 to 30) kHz (30 to 100) kHz 37 µA/A 37 µA/A 39 µA/A 59 µA/A 37 µA/A 37 µA/A 39 µA/A 59 µA/A 38 µA/A 41 µA/A 43 µA/A 75 µA/A 48 µA/A 63 µA/A 96 µA/A 0.21 mA/A Fluke A40B series shunts, Fluke 5790 AC Current3 – Generate (0.02 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz 0.93 mA/A + 30 nA 0.49 mA/A + 25 nA 0.20 mA/A + 20 nA 0.83 mA/A + 50 nA 0.21 % + 0.1 µA 0.93 mA/A + 50 nA 0.49 mA/A + 40 nA 0.19 mA/A + 40 nA 0.82 mA/A + 0.5 µA 0.21 % + 1.0 µA 0.94 mA/A + 0.5 µA 0.49 mA/A + 0.4 µA 0.19 mA/A + 0.4 µA 0.82 mA/A + 5.0 µA 0.21 % + 10 µA 0.93 mA/A + 5.0 µA 0.49 mA/A + 4.0 µA 0.22 mA/A + 4.0 nA 0.82 mA/A + 50 µA 0.21 % + 0.10 mA Fluke 5700A
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 18 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current3 – Generate (cont) (0.22 to 2.2) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (20.5 to 150) A Toroidal Non-Toroidal (150 to 1000) A Toroidal Non-Toroidal (0.02 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.87 mA/A + 40 µA 0.99 mA/A + 0.10 mA 1.2 % + 0.20 mA 0.21 % + 0.10 mA 0.76 mA/A + 0.10 mA 0.70 % + 1.0 mA 2.9 % + 5.0 mA 0.74 mA/A + 2.0 mA 0.12 % + 2.0 mA 3.5 % + 2.0 mA 0.15 % + 5.0 mA 0.18 % + 5.0 mA 3.5 % + 5.0 mA 0.41 mA/A 0.96 mA/A 8.7 mA/A 14 mA/A 0.41 mA/A 0.96 mA/A 7.9 mA/A 13 mA/A Fluke 5520A Fluke 5520A, 5500A/coil
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 19 of 52 Parameter/Equipment Range CMC2, 7 (±) Comments DC Watts – Generate3 (0.010 89 to 10.89) mW (10.890 to 99) mW (99 to 336.6) W (336.6 to 3060) W (3060 to 20 910) W 0.033 % 0.14 % 0.14 % 0.12 % 0.07 % Fluke 5520A AC Watts – Generate3 (45 to 65) Hz/PF=1 (0.1089 to 0.297) mW (0.297 to 2.97) mW (2.97 to 10.89) mW (10.89 to 72.60) mW (72.60 to 1485) mW (1.485 to 6.765) W (6.765 to 33.66) W (33.66 to 336.6) W (336.6 to 917.9) W (917.9 to 2244) W (2244 to 20 910) W 0.17 % 0.13 % 0.12 % 0.24 % 0.23 % 0.21 % 0.19 % 0.22 % 0.21 % 0.23 % 0.13 % Fluke 5520A Phase Angle3 – Measure (0 to 359.9999) ° Generate (0 to 999.999) ° 10 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 200) kHz 1 Hz to 1 kHz (1 to 50) kHz (50 to 200) kHz 0.012° 0.017° 0.051° 0.11° 0.028° 0.056° 0.068° North Atlantic PAV 2250A Clarke Hess 5000 Inductance3 – Measure Generate Fixed points (0.1 to 10) µH (0.01 to 10) mH 0.01 to 100) mH (0.1 to 10) kH (10 to 100) kH 20 mH 100 mH 200 mH 2 H 0.022 µH 0.21 µH 0.02 H 6.4 H 0.61 kH 0.012 mH 0.054 mH 0.12 mH 1.3 mH HP 4284A General radio 1482 series inductors
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 20 of 52 Parameter/Equipment Range CMC2, 7 (±) Comments Inductance3 – (cont) Variable (1 to 10) mH (10 to 100) mH (0.1 to 1) H (1 to 10) H 9.5 µH 0.81 mH 0.011 H 0.2 H General radio 1490D Capacitance3 – Fixed 1 nF 2 nF 10 nF 100 nF 200 nF 1 µF 0.50 pF 1.1 pF 5.4 pF 7.4 pF 0.10 nF 0.19 nF General radio 1409 series standard capacitors Capacitance3 – Measure Generate (0 to 1) nF (0.001 to 10) µF (0.001 to 10) mF (0.01 to 110) mF (0.19 to 0.4) nF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 100) mF 1.1 pF 5.4 nF 0.011 mF 0.28 mF 0.26 % + 13 pF 0.56 % + 12 pF 0.27 % + 13 pF 0.29 % + 120 pF 0.27 % + 140 pF 0.27 % + 390 pF 0.27 % + 1.3 nF 0.27 % + 3.9 nF 0.25 % + 15 nF 0.26 % + 42 nF 0.38 % + 170 nF 0.45 % + 480 nF 0.50 % + 1.4 µF 0.44 % + 4.9 µF 0.26 % + 36 µF 0.78 % + 49 µF 0.83 % + 360 µF 1.1 % + 360 µF HP 4284A Fluke 5520A
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 21 of 52 Parameter/Equipment Range CMC2, 7 (±) Comments Thermocouple Indicating_Simulation3, 1_2 Type E Type J Type K Type N Type R Type S Type T (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -30) °C (-30 to 50) °C (50 to 500) °C (500 to 1200) °C (-200 to -100) °C (-100 to -30) °C (-30 to 120) °C (120 to 1050) °C (1050 to 1371.1) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to -100) °C (-100 to 0) °C (0 to 400) °C 0.58 °C 0.20 °C 0.18 °C 0.20 °C 0.26 °C 0.30 °C 0.29 °C 0.16 °C 0.23 °C 0.35 °C 0.19 °C 0.17 °C 0.15 °C 0.23 °C 0.42 °C 0.24 °C 0.21 °C 0.20 °C 0.28 °C 0.62 °C 0.41 °C 0.37 °C 0.43 °C 0.53 °C 0.41 °C 0.41 °C 0.49 °C 0.64 °C 0.26 °C 0.18 °C 0.15 °C Fluke 5520A
22

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 22 of 52 Parameter/Equipment Range CMC2 (±) Comments RTD Simulation3, 1_2 Cu427 Ni120 Pt 385, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω Pt 3916, 100 Ω Pt 3926, 100 Ω 100 to 260 °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 600) °C (600 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C 0.34 °C 0.085 °C 0.084 °C 0.15 °C 0.090 °C 0.093 °C 0.11 °C 0.13 °C 0.14 °C 0.15 °C 0.25 °C 0.046 °C 0.055 °C 0.13 °C 0.14 °C 0.15 °C 0.17 °C 0.042 °C 0.051 °C 0.061 °C 0.081 °C 0.092 °C 0.12 °C 0.031 °C 0.041 °C 0.052 °C 0.062 °C 0.072 °C 0.23 °C 0.28 °C 0.058 °C 0.067 °C 0.075 °C 0.093 °C 0.11 °C 0.11 °C 0.12 °C 0.24 °C 0.066 °C 0.083 °C 0.11 °C 0.12 °C 0.14 °C Fluke 5520A
23--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 23 of 52 Parameter/Equipment Range CMC2 (±) Comments Oscilloscopes – Amplitude – DC Signal3 50 Ω Load 1 MΩ Load Amplitude – Square Wave 50 Ω Load 1 MΩ Load (0 to 6) V (0 to 130) V 1 mV p-p to 6.6 Vp-p; 10 Hz to 10 kHz 1 mV p-p to 130 Vp-p; 10 Hz to 10 kHz 29 mV/V + 0.58 mV 590 µV/V + 75 µV 29 mV p-p/Vp-p + 75 µVp-p 280 µV p-p/Vp-p + 75 µVp-p 5520A-SC1100 multifunction calibrator w/ oscilloscope opt Oscilloscopes – Rise Time (0.001 to 2) MHz (2 to 10) MHz (200 to 300) ps (250 to 350) ps 120 ps 140 ps 5520A-SC1100 multifunction calibrator w/ oscilloscope opt Oscilloscopes – Bandwidth 3 5 mV to 5.5 Vp-p 4 mV to 3.5 V p-p Leveled Sine Wave – Frequency3 Time Marker 50 kHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 kHz to 1.1 GHz 2 ns to 20 ms 50 ms to 5 s 58 mVp-p/Vp-p + 470 µVp-p 58 mVp-p/Vp-p + 470 µVp-p 70 mVp-p/Vp-p + 470 µVp-p 120 mVp-p/Vp-p + 470 µVp-p 140 mVp-p/Vp-p + 470 µVp-p 0.58 kHz 2.9 µs/s + 0.15 ps 1.2 ms/s + 58 µs 5520A-SC1100 multifunction calibrator w/ oscilloscope opt Dissipation Factor – Measure (Df)3 1 pF to 100 µF (0.0001 to 10) Df 3.5 % + 1 cts Multi-frequency LCR Meter cts: Counts of LSD
0.0001 to 10 Df
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 24 of 52 Parameter/Equipment Range CMC2 (±) Comments Oscilloscopes – Wave Functions - Square, Sine, & Triangle3 50 Ω Load 1 MΩ Load Pulse Characteristics3 – Pulse Width Pulse Period Rise Time – Generate 1.8 mV p-p to 2.5 Vp-p; 10 Hz to 10 kHz 1.8 mVp-p to 55 Vp-p; 10 Hz to 10 kHz (4 to 500) ns 200 ns to 20 ms 1 kHz to 2 MHz (200 to 300) ps 2 to 10 MHz (200 to 350) ps 35 mV p-p/Vp-p + 120 µVp-p 35 mVp-p/Vp-p + 120 µVp-p 2.6 ns 150 ps 120 ps 120 ps 5520A-SC1100 multifunction calibrator w/ oscilloscope opt IV. Electrical – RF/Microwave Parameter/Range Frequency CMC2, 7 (±) Comments RF Power3 – Measure (-67 to +20) dB (-35 to +20) dB (-30 to +20) dB 10 MHz to 40 GHz DC to 100 MHz 100 MHz to 4 GHz (4 to 8) GHz (8 to 12.4) GHz (12.4 to 18) GHz (18 to 26.5) GHz (26.5 to 30) GHz (30 to 35) GHz (35 to 40) GHz 50 MHz to 50 GHz 0.82 dB 0.061 dB 0.077 dB 0.091 dB 0.11 dB 0.13 dB 0.11 dB 0.13 dB 0.14 dB 0.14 dB 0.11 dB Anritsu MA2444D Rohde & Schwarz NRP-Z55 HP 8487A, Agilent E4418B
25

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 25 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments RF Power – Generate (-100 to +24) dB (-100 to +20) dB (-100 to +18) dB Leveled Sine Wave – Generate (-130 to -94) dBm (-94 to -84) dBm (-84 to -74) dBm (-74 to -48) dBm (-48 to -17) dBm (-17 to +14) dBm (+14 to +20) dBm (+20 to +24) dBm 1 mHz to 4.024 GHz (1.4 to 20) GHz (20 to 26.5) GHz (10 to 128) MHz 128 MHz to 3 GHz 100 kHz to 10 MHz (10 to 128) MHz (128 to 300) MHz 300 MHz to 3 GHz 100 kHz to 10 MHz (10 to 128) MHz (128 to 300) MHz 300 MHz to 1.4 GHz (1.4 to 4) GHz 100 kHz to 10 MHz (10 to 128) MHz (128 to 300) MHz 300 MHz to 1.4 GHz (1.4 to 4) GHz (10 to 100) kHz 100 kHz to 128 MHz (128 to 300) MHz 300 MHz to 1.4 GHz (1.4 to 3) GHz (3 to 4) GHz (10 to 100) kHz 100 kHz to 128 MHz (128 to 300) MHz 300 MHz to 1.4 GHz (1.2 to 4) GHz (10 to 100) kHz 100 kHz to 128 MHz (128 to 300) MHz 300 MHz to 1.4 GHz (10 to 100) kHz 100 kHz to 128 MHz 0.60 dB 1.2 dB 1.2 dB 0.74 dB 1.6 dB 0.52 dB 0.35 dB 0.51 dB 1.1 dB 0.51 dB 0.13 dB 0.33 dB 0.54 dB 1.1 dB 0.21 dB 0.11 dB 0.11 dB 0.43 dB 0.58 dB 0.032 dB 0.062 dB 0.079 dB 0.22 dB 0.38 dB 0.53 dB 0.031 dB 0.059 dB 0.079 dB 0.22 dB 0.33 dB 0.051 dB 0.058 dB 0.11 dB 0.26 dB 0.031 dB 0.059 dB Fluke 96270A leveled microwave output Fluke 96270A
26

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 26 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments Attenuation3, 5 – Measure 10 Hz to 128 MHz (0 to 55) dB (55 to 64) dB (64 to 100) dB (100 to 116) dB 0.044 dB 0.057 dB 0.17 dB 0.23 dB Fluke 96270A, Rohde & Schwarz FSP Amplitude Modulation3 – Measure Carrier: 150 kHz to 10 MHz Rate: 50 Hz to 10 kHz Rate: 20 Hz to 10 kHz Carrier: 10 MHz to 1.3 GHz Rate: 50 Hz to 50 kHz Rate: 20 Hz to 100 kHz Depth: (5 to 99) % Depth: (5 to 99) % Depth: (5 to 99) % Depth: (5 to 99) % 2.7 % 3.8 % 1.9 % 3.8 % HP 8901B Amplitude Modulation3 – Generate Carrier: 50 kHz to 4 GHz Rate: 1 Hz to 100 kHz Depth: (5 to 10) % Depth: (10 to 99) % 1.6 % 3.9 % Fluke 96270A Frequency Modulation3 –Measure Carrier: 150 kHz to 10 MHz Rate: 20 Hz to 10 kHz Carrier: 10 MHz to 1.3 GHz Rate: 50 Hz to 100 kHz Carrier: 10 MHz to 1.3 GHz Rate: 20 Hz to 200 kHz Deviation: Up to 40 kHz Deviation: Up to 400 kHz Deviation: Up to 400 kHz 26 mHz/Hz + 310 mHz 15 mHz/Hz + 320 mHz 59 mHz/Hz + 290 mHz HP 8901B Frequency Modulation3 –Generate Carrier: 9 MHz to 31.25 MHz Rate: 1 Hz to 50 kHz Rate: 50 Hz to 300 kHz Carrier: 31.25 MHz to 125 MHz Rate: 1 Hz to 50 kHz Rate: 50 Hz to 300 kHz Carrier: 125 MHz to 4 GHz Rate: 1 Hz to 50 kHz Rate: 50 Hz to 300 kHz Deviation: 10 Hz to 300 kHz Deviation: 10 Hz to 750 kHz Deviation: 10 Hz to 4.8 MHz 11 mHz/Hz 60 mHz/Hz 11 mHz/Hz 36 mHz/Hz 11 mHz/Hz 36 mHz/Hz Fluke 96270A
27--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 27 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments Phase Modulation3 – Measure Carrier: 150 kHz to 10 MHz Rate: 200 Hz to 10 kHz Carrier: 10 MHz to 1.3 GHz Rate: 200 Hz to 20 kHz Deviation: Up to 420 rad Deviation: Up to 420 rad 0.050 rad/rad + 0.067 rad 0.040 rad/rad + 0.067 rad HP 8901B Amplitude Modulation3 – Sine Distortion (10.0 to 89.0) % 50 kHz to 125 MHz -40 dBc HP 8903B Phase Modulation3 –Generate Carrier: 9 MHz to 4 GHz Rate: 1 Hz to 50 kHz Rate: 50 kHz to 300 kHz Deviation: Up to 1000 rad 0.011 rad/rad 0.036 rad/rad Fluke 96270A Total Harmonic Distortion3 47 Hz to 100 kHz 1.7 % North Atlantic PAV 2250A VI. Mechanical Parameter/Equipment Range CMC2, 6 (±) Comments Accelerometers3 Voltage Sensitivity – Up to 1000 mV/g’s 50 Hz to 2 kHz (2 to 10) kHz (5 to 9) Hz (10 to 99) Hz 100 Hz (101 to 1999) Hz (2 to 10) kHz 3.5 % 5.0 % 2.7 % 2.6 % 2.3 % 2.3 % 5.6 % Modal Shop 9100D Portable Modal shop 9150D shaker, digital multimeter, Function generator, PCB signal conditioner
to 420 rad
28

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 28 of 52 Parameter/Equipment Range CMC2, 6, 8 (±) Comments Scales & Balances3 – Linearity Only (1 to 50) mg (50 to 500) mg (0.5 to 1) g (1 to 5) g (5 to 50) g (50 to 100) g (100 to 200) g (200 to 2000) g (2000 to 6000) g (1.0 to 2.0) lbf (2.0 to 5.0) lbf (5.0 to 10.0) lbf (10.0 to 20.0) lbf (20.0 to 100.0) lbf (100.0 to 200.0) lbf 0.017 mg 0.027 mg 0.055 mg 0.055 mg 0.16 mg 0.64 mg 0.77 mg 6.9 mg 0.14 g 1.1 x 10 -3 lbf 2.0 x 10-3 lbf 3.5 x 10-3 lbf 2.6 x 10-3 lbf 9.2 x 10-3 lbf 1.6 x 10-2 lbf Class 1 weights Reference Weights Force – Measuring Equipment3 (1 to 100) lb (50 to 500) lb (0.5 to 5) klb (10 to 100) klb 0.052 % 0.090 % 0.16 % 0.049 % Transducer techniques MDB-10, Rice Lake RL20000I-100, Rice Lake RL2000I-T10-500 Interface RL9000TWM- 5K Omega LCW-100K Pneumatic Pressure – Measuring Equipment 3 (-15 to 0) psig Up to 5 psig (5 to 15) psig Up to 15 psig (15 to 30) psig Up to 45 psig (45 to 90) psig Up to 150 psig (150 to 300) psig Up to 500 psig (500 to 1000) psig Up to 1500 psig (1500 to 3000) psig 3000 to 6000 psig (6000 to 10 000) psig 0.0015 psi 0.001 psi 0.003 psi 0.0015 psi 0.003 psi 0.0046 psi 0.0091 psi 0.015 psi 0.030 psi 0.051 psi 0.10 psi 0.15 psi 0.31 psi 8.6 psi 9.5 psi Fluke PM500 Fluke PPC4EX Fluke PM500 Fluke 700P31
29--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 29 of 52 Parameter/Equipment Range CMC2, 6, 8 (±) Comments Tachometers3 – Optical (30 to 250 000) rpm 12 µRPM/RPM + 0.6R Fluke 5520A with LED Torque – Measure3 (1 to 9) lbf·in (5 to 50) lbf·in (50 to 300) lbf·in (10 to 150) lbf·ft (150 to 600) lbf·ft (600 to 1000) lbf·ft 2.1 % 0.64 % 0.38 % 0.35 % 0.31 % 7.1 lbf·ft Delta Regis DRBT-10 Sturtevant Richmont system 8 w/ transducers Torque transducers w/ torque analyzer Mass Flow (Gas) – Measure (0 to 0.5) slpm (0.5 to 5) slpm (5 to 50) slpm (50 to 100) slpm 0.03 % + 0.0011 slpm 0.26 % + 0.03 slpm 0.26 % + 0.0002 slpm 0.13 % + 0.0002 slpm Fluke Molbox1+ A700K, Molbloc-L 3E4-VCR-V- Q, Molbloc-L 5E3-VCR- V-Q V. Thermodynamics Parameter/Equipment Range CMC2, 8 (±) Comments Humidity3 – Measuring Equipment (5 to 95) % RH 0.84 % RH Rotronic HF53W-ID, Rotronic HC2A probe Temperature3 – Measuring Equipment Thermometers Infrared (-20 to 375) °C (375 to 600) °C (-15 to 0) °C (0 to 50) °C (50 to 100) °C (100 to 120) °C (35 to 100) °C (100 to 200) °C (200 to 350) °C (350 to 500) °C (500 to 1000) °C (1000 to 1100) °C (1100 to 1400) °C (1400 to 1500) °C 0.088 °C 0.32 °C 0.96 °C 0.99 °C 1.0 °C 1.2 °C 0.82 °C 1.4 °C 2.0 °C 3.0 °C 7 °C 9 °C 10 °C 11 °C WIKA CTP5000-450 probe Fluke 4180 wavelength (8 to 14) µm emissivity 0.95 Fluke 4181 wavelength (8 to 14) µm emissivity 0.95 Mikron 335 wavelength (0.65 to 1.8) µm emissivity 1.0
30 to 250000 rpm
30

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 30 of 52 Parameter/Equipment Range CMC2, 8 (±) Comments Infrared – Measure3 (30 to 100) °C (100 to 150) °C (150 to 200) °C (200 to 250) °C (160 to 500) °C (500 to 900) °C (900 to 1300) °C (1300 to 1650) °C 2.4 °C 3.5 °C 4.7 °C 6 °C 3 °C 4 °C 5 °C 5 °C Infrared camera Fluke VT04 wavelength (6.5 to 14) µm emissivity 0.01 to 1.0 Infrared camera Williamson SW-22- 45C-FOV wavelength (2.2) µm emissivity 0.01 to 1.5 Temperature – Measure (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 420) °C (420 to 550) °C (550 to 660) °C (660 to 700) °C (700 to 800) °C (800 to 900) °C (900 to 1000) °C 0.084 °C 0.034 °C 0.037 °C 0.085 °C 0.12 °C 0.13 °C 3.8 °C 4.0 °C 4.0 °C 4.0 °C Fluke 5615-12 probe, Fluke 1524 reference thermometer Fluke 9144 w/ Fluke 5609 SPRT Pyromation S-type probe VI. Time & Frequency Parameter/Equipment Range CMC2, 8 (±) Comments Frequency3 – Measuring Equipment Reference Oscillator 0.001 Hz to 10 kHz 10 kHz to 4 GHz (4 to 26) GHz 10 MHz 0.091 µHz/Hz 0.060 µHz/Hz 0.058 µHz/Hz 0.12 mHz Fluke 96270A Trimble Thunderbolt E Frequency3 – Measure 1 mHz to 3 GHz (3 to 20) GHz 30 nHz/Hz 46 nHz/Hz Agilent 53132A Agilent 53147A Timers/Stopwatches3 Up to 24 hr 0.065 s/day Timometer 4500 _____________________________________
31

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 31 of 52 SATELLITE 1338 Sadlier Circle Drive East Indianapolis, IN 46239 Kenton Shepherd Phone: 260 471 6775 CALIBRATION In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 11: I. Acoustical Quantities Parameter/Equipment Range CMC2, 8 (±) Comments Sound Level – Measuring Equipment, Fixed Points3 94 dB 114 dB 0.28 dB 0.28 dB Bruel & Kjaer 4231 II. Chemical Parameter/Equipment Range CMC2 (±) Comments pH Meters, Fixed Points3 4 pH 7 pH 10 pH 0.017 pH 0.012 pH 0.019 pH Standard pH solutions Conductivity Meters3 ≈10 µS/cm ≈1413 µS/cm ≈10 mS/cm ≈100.9 mS/cm 4.4 µS/cm 9.8 µS/cm 0.15 mS/cm 2.2 mS/cm Standard conductivity solutions
32--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 32 of 52 III. Dimensional Parameter/Equipment Range CMC2, 6 (±) Comments Calipers3 – Dial, Digital, Vernier – Length Parallelism Up to 18 in (18 to 48) in Up to 2 in (290 + 7.3L) µin (240 + 4.9L) µin 30 µin Gage blocks Depth Gauge3 – Dial, Digital, Vernier (0.001 to 48) in (59 + 7.2L) µin Gage blocks, surface plate Height Gauges3 Up to 18 in (18 to 36) in (30 + 6.5L) µin (16 + 7.3L) µin Gage blocks Indicators – Dial & Digital 3 (0.000 01 to 2) in (11 + 8.9L) µin Gage blocks, surface plate, Pratt & Whitney Supermic TM Length Standards3 (Length only) Up to 10 in (3.2 + 1.0L) µin P&W PC25 Measuring Tapes3,6 Up to 300 in 0.015 + (0.004S) in Master ruler, measuring tape fixture. Micrometers3 – OD ID Flatness Parallelism Up to 48 in Up to 24 in Up to 2 in Up to 2 in (30 + 13L) µin (30 + 13L) µin 4.3 µin 4.3 µin Gage blocks Optical flat Protractors3 Up to 90° 0.060° Surface plate, sine bar, gage blocks
to 300 in
33ASME/ANSI B1.2- 1983; ASME/ANSI B1.3- 2007-See scope document
34

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 34 of 52 V. Electrical DC/Low Frequency Parameter/Equipment Range CMC2, 7 (±) Comments DC Voltage3 – Measure 0 V Short (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 10) kV (10 to 100) kV (100 to 125) kV (125 to 140) kV 0.62 µV/V 2.7 µV/V + 0.84 µV 2.0 µV/V + 5.7 µV 4.4 µV/V + 88 µV 1.5 µV/V + 2.0 mV 5.3 µV/V + 2.0 mV 0.35 mV/V + 35 mV 0.58 mV/V + 0.50 V 0.17 kV 0.29 kV Copper short HP 3458A Opt. 002 digital multimeter Vitrek 4700 high voltage multimeter, Vitrek HVL- 150 high voltage probe DC Voltage3 – Generate (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V (0.1 to 1.0) kV (1.0 to 4.0) kV (4.0 to 9.0) kV (9.0 to 25) kV (25 to 50) kV (50 to 60) kV 9.6 µV/V + 0.63 µV 4.3 µV/V + 4.4 µV 4.0 µV/V + 4.5 µV 4.1 µV/V + 4.9 µV 5.7 µV/V + 98 µV 7.8 µV/V + 660 µV 0.61 V 2.5 V 4.7 V 38 V 58 V 81 V Fluke 5700A HV Source monitored by Vitric 4700 HV Source monitored. by Vitrek 4700/HVL150 probe DC Current3 – Measure (0 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 10) A (10 to 1000) A (1 to 2.8) kA 36 µA/A + 0.5 nA 31 µA/A + 5 nA 32 µA/A + 50 nA 52 µA/A + 0.5 µA 0.15 mA/A + 5uA 0.26 mA/A 4.2 mA/A + 0.5A 12 mA/A + 0.5A HP 3458A opt. 002 digital multimeter Y5020 LEM PR2000 current clamp, HP 3458A opt. 002 digital multimeter
35

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 35 of 52 Parameter/Equipment Range CMC2, 7 (±) Comments DC Current3 – (cont) Generate Clamp Meters (0 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (1.3 to 3) A (3 to 11) A (11 to 20.5) A (20.5 to 1000) A 10 nA/A + 7.1 nA 8.7 nA/A + 13 nA 8.7 nA/A + 49 nA 1.1 nA/A + 0.84 µA 2.0 nA/A + 31 µA 400 µA/A + 1.5 mA 1 mA/A + 2.4 mA 1.1 mA/A + 2.4 mA 6.0 mA/A + 0.60 A Fluke 5700A Fluke 5520A w/ coil Resistance3 – Generate Fixed 0.000 333 3 Ω 0.001 Ω 0.01 Ω 0.1 Ω 1 Ω 10 Ω 100Ω 1k Ω 10 kΩ 10 MΩ 1 GΩ 10 GΩ 100 GΩ 1 TΩ 0 Ω 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 1.2 mΩ/Ω 0.58 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.12 mΩ/Ω 0.32 kΩ 0.56 MΩ 0.61 MΩ 0.12 GΩ 2.6 GΩ 47 µΩ 110 µΩ 110 µΩ 35 µΩ 43 µΩ 0.15 mΩ 0.28 mΩ 1.6 mΩ 2.9 mΩ 15 mΩ 29 mΩ 0.18 Ω 0.30 Ω 17 Ω 19 Ω 71 Ω 250 Ω 4.2 kΩ 9211A Guildline Metrohm P4085 series resistors Fluke 5700A
36

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 36 of 52 Parameter/Equipment Range CMC2, 7 (±) Comments Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω (100 to 1000) Ω (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 100) MΩ 100 MΩ to 1 GΩ Up to 2 Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ (2 to 20) GΩ 29 µΩ/Ω + 0.58 mΩ 12 µΩ/Ω + 0.58 mΩ 12 µΩ/Ω + 5.8 mΩ 12 µΩ/Ω + 58 mΩ 18 µΩ/Ω + 2.3 Ω 58 µΩ/Ω + 0.12 kΩ 5.8 mΩ/Ω + 12 kΩ 5.8 mΩ/Ω + 12 kΩ 28 µΩ/Ω 25 µΩ/Ω 17 µΩ/Ω 14 µΩ/Ω 14 µΩ/Ω 14 µΩ/Ω 19 µΩ/Ω 28 µΩ/Ω 0.014 % 0.12 % 0.23 % HP 3458A Opt. 002, digital multimeter Fluke 8508A Resistance3 – Generate (0 to 1) Ω (1 to 1.9) Ω (1.9 to 10) Ω (10 to 19) Ω (19 to 100) Ω (100 to 190) Ω (190 to 1000) Ω (1000 to 1900) Ω (1.9 to 10) kΩ (10 to 19) kΩ (19 to 100) kΩ (100 to 190) kΩ (0.19 to 1) MΩ (1 to 1.9) MΩ (1.9 to 100) MΩ 46 µΩ/Ω + 1.2 mΩ 46 µΩ/Ω + 1.2 mΩ 46 µΩ/Ω + 1.2 mΩ 34 µΩ/Ω + 1.8 mΩ 28 µΩ/Ω + 3.5 mΩ 28 µΩ/Ω + 3.5 mΩ 29 µΩ/Ω + 6.3 mΩ 27 µΩ/Ω + 4.0 mΩ 26 µΩ/Ω + 100 mΩ 27 µΩ/Ω + 40 mΩ 26 µΩ/Ω + 1 Ω 33 µΩ/Ω + 3.4 Ω 30 µΩ/Ω + 11 Ω 63 µΩ/Ω + 0.05 kΩ 0.52 mΩ/Ω + 10 kΩ Fluke 5520A Resistance3 – Current Shunt Up to 80 mΩ (80 to 800) mΩ (0.8 to 1000) Ω 320 µΩ/Ω + 1.3 nΩ 140 µΩ/Ω + 4.7 nΩ 81 µΩ/Ω + 16 µΩ Fluke 5520A, HP 3458A Opt.002 digital multimeter
37

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 37 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate (0.005 to 2.2) mV (2.2 to 22) mV (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 0.022 % + 5.2 µV 0.011 % + 5.2 µV 0.011 % + 5.2 µV 0.038 % + 5.2 µV 0.087 % + 8.1 µV 0.12 % + 15 µV 0.17 % + 29 µV 0.36 % + 29 µV 0.022 % + 5.8µV 0.011 % + 5.8µV 0.011 % + 5.8µV 0.039 % + 5.9µV 0.088 % + 8.1µV 0.12 % + 16 µV 0.18 % + 29µV 0.34 % + 36 µV 0.022 % + 9.5 µv 0.011 % + 9.6 µv 0.011 % + 9.4 µV 0.018 % + 62 µV 0.058 % + 130 µV 0.11 % + 37 µV 0.18 % + 41 µV 0.37 % + 93 µV 0.016 % + 48 µV 0.074 % + 14 µV 0.075 % + 11 µV 29 µV/V + 0.70 mV 0.016 % + 0.38 mV 0.046 % + 0.15 mV 0.11 % + 0.42 mV 0.22 % + 1.0 mV 0.016 % + 0.38 mV 73 µV/V + 0.15 mV 75 µV/V + 0.12 mV 0.011 % + 0.82 mV 0.024 % + 0.47 mV 0.053 % + 1.7 mV 0.14 % + 5.0 mV 0.29 % + 1.0 mV Fluke 5700A
38

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 38 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate (cont) (22 to 220) V (220 to 750) V (750 to 1050) V (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (10 to 20) Hz (20 to 40) Hz (0.04 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (15 to 50) Hz (0.05 to 1) kHz (0.04 to 10) kHz (10 to 33) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz (0.045 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.045 to 1) kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.17 % + 3.9 mV 80 µV/V + 1.6 mV 82 µV/V + 1.2 mV 0.023 % + 4.2 mV 0.53 % + 9.5 mV 0.17 % + 0.11 V 0.53 % + 0.11 V 1.3 % + 0.22 V 0.043 % + 19 mV 77 µV/V + 9.3 mV 29 µV/V 0.13 mV/V 99 µV/V + 19 µV 99 µV/V + 19 µV 9.3 µV/V + 250 µV 48 µV/V + 140 µV 0.045 % + 100 µV 0.22 % + 87 µV 0.012 % + 0.12 mV 0.012 % + 0.12 mV 13 µV/V + 1.8 mV 35 µV/V + 1.1 mV 0.045 % + 0.43 mV 0.26 % + 0.80 mV 0.017 % + 0.71 mV 0.017 % + 0.71 mV 0.027 % + 0.72 mV 0.040 % + 0.74 mV 0.10 % + 1.9 mV 0.28 % + 0.80 mV 0.021 % + 3.0 mV 0.022 % + 7.8 mV 0.024 % + 10 mV 0.019 % + 20 mV 0.22 % + 62 mV 0.033 % + 19 mV 0.030 % + 32 mV 0.028 % + 11 mV 0.31 % + 20 mV 0.23 % + 63 mV Fluke 5700A
39

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 39 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Generate (cont) (330 to 1020) V (0.1 to 1.0) kV (1.0 to 4.0) kV (4.0 to 9.0) kV (9.0 to 10) kV (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (50 to 60) Hz (50 to 60) Hz (50 to 60) Hz (50 to 60) Hz 0.034 % + 19 mV 0.028 % + 20 mV 0.033 % + 32 mV 2.1 V 6.4 V 18 V 0.12 kV Fluke 5520A HV source monitored by Vitrek 4700 HV source monitored by Vitrek 4700 w/ HVL-150 probe AC Voltage3 – Measure 10 mV 100 mV 1 V 10 V (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 2) MHz (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 1) MHz (1 to 2) MHz 790 µV/V + 1.1 µV 98 µV/V + 9.0 µV 170 µV/V + 16 µV 320 µV/V + 32 µV 820 µV/V + 82 µV 10 mV/V + 1.1 mV 130 µV/V + 11 µV 98 µV/V + 9 µV 170 µV/V + 16 µV 320 µV/V + 32 µV 0.83 mV/V + 82 µV 3.1 mV/V + 0.31 mV 11 mV/V + 1.1 mV 16 mV/V + 1.5 mV 7.9 mV/V + 0.11 mV 4.1 mV/V + 90 µV 4.8 mV/V + 0.16 mV 4.4 mV/V + 0.32 mV 3.8 mV/V + 0.9 mV 8.1 mV/V + 3.1 mV 16 mV/V + 11 mV 20 mV/V + 15 mV 0.79 mV/V + 1.1 mV 0.41 mV/V + 0.9 mV 0.50 mV/V + 1.6 mV 0.55 mV/V + 3.2 mV 0.9 mV/V + 8.2 mV 3.2 mV/V + 31 mV 11 mV/V + 0.11 V 16 mV/V + 0.16 V HP 3458 opt. 002 digital multimeter
40

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 40 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 – Measure (cont.) 100 V 700 V (1 to 9) kV (9 to 20) kV (20 to 40) kV (40 to 60) kV (60.0 to 80) kV (80.0 to 100.0) kV (1 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (10 to 40) Hz (40 to 1000) Hz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (0.01 to 600) Hz (30 to 200) Hz (30 to 200) Hz (30 to 200) Hz (30 to 200) Hz (30 to 200) Hz 1.1 mV/V + 24 mV 0.22 mV/V + 22 mV 0.22 mV/V + 22 mV 0.37 mV/V + 37 mV 1.3 mV/V + 0.13 V 4.1 mV/V + 0.41 V 16 mV/V + 1.6 V 0.45 mV/V + 37 mV 0.45 mV/V + 37 mV 1.4 mV/V + 42 mV 3.5 mV/V + 42 mV 3.5 mV/V + 42 mV 11 V 30 V 54 V 78 V 0.10 kV 0.13 kV Vitrek 4700 high voltage multimeter Vitrek 4700 with HVL- 150 high voltage probe AC Current3 – Measure Up to 100 µA (1 to 100) mA (0.1 to 1) A (1 to 20) A (20 to 2800) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 1) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (2 to 10) kHz 3 Hz to 10 kHz 1 Hz to 10 kHz 1.9 mA/A + 0.56 µA 0.37 mA/A + 0.58 µA 91 µA/A + 0.58 µA 84 µA/A + 0.57 µA 4.7 mA/A + 24 µA 1.8 mA/A + 24 µA 0.70 mA/A + 24 µA 0.35 mA/A + 24 µA 0.70 mA/A + 24 µA 4.7 mA/A + 47 µA 6.4 mA/A + 170 µA 4.7 mA/A + 0.24 mA 1.9 mA/A + 0.24 mA 0.92 mA/A + 0.25 mA 2.1 mA/A + 0.25 mA 3.5 mA/A + 0.24 mA 12 mA/A + 0.47 mA 0.10 % 0.30 % 12 mA/A HP 3458 opt. 002 digital multimeter Fluke Y5020 LEM PR2000
41

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 41 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current3 – Generate (0.02 to 220) µA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (20.5 to 150) A Toroidal Non-Toroidal (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz (0.04 to 1) kHz (1 to 5) kHz (5 to 10) kHz (0.02 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz (0.045 to 1) kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 100) Hz (0.1 to 1) kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz 45 to 65) Hz (65 to 440) Hz 0.93 mA/A + 30 nA 0.49 mA/A + 25 nA 0.20 mA/A + 20 nA 0.83 mA/A + 50 nA 0.21 % + 0.1 µA 0.93 mA/A + 50 nA 0.49 mA/A + 40 nA 0.19 mA/A + 40 nA 0.82 mA/A + 50 nA 0.21 % + 1 µA 0.93 mA/A + 50 nA 0.49 mA/A + 40 nA 0.19 mA/A + 40 nA 0.81 mA/A + 50 nA 0.21 % + 1 µA 0.93 mA/A + 4 µA 0.49 mA/A + 4 µA 0.22 mA/A + 0.4 µA 0.82 mA/A + 50 nA 0.21 % + 1µA 0.87 mA/A + 40 µA 0.99 mA/A + 0.10 mA 1.2 % + 0.20 mA 0.21 % + 0.10 mA 0.76 mA/A + 0.10 mA 0.70 % + 1.0 mA 2.9 % + 5.0 mA 0.74 mA/A + 2.0 mA 0.12 % + 2.0 mA 3.5 % + 2.0 mA 0.15 % + 5.0 mA 0.18 % + 5.0 mA 3.5 % + 5.0 mA 0.41 mA/A 0.96 mA/A 8.7 mA/A 14 mA/A Fluke 5700A Fluke 5520A Fluke 5520A, 5500A/coil
42

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 42 of 52 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current3 – Generate (cont) (150 to 1000) A Toroidal Non-Toroidal (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.41 mA/A 0.96 mA/A 7.9 mA/A 13 mA/A Fluke 5520A, 5500A/coil Parameter/Equipment Range CMC2, 7 (±) Comments DC Watts – Generate3 (0.010 89 to 10.89) mW (10.890 to 99) mW (99 to 336.6) W (336.6 to 3060) W (3060 to 20 910) W 0.033 % 0.14 % 0.14 % 0.12 % 0.07 % Fluke 5520A AC Watts – Generate3, (45 to 65) Hz/PF=1 (0.1089 to 0.297) mW (0.297 to 2.97) mW (2.97 to 10.89) mW (10.89 to 72.60) mW (72.60 to 1485) mW (1.485 to 6.765) W (6.765 to 33.66) W (33.66 to 336.6) W (336.6 to 917.9) W (917.9 to 2244) W (2244 to 20 910) W 0.17 % 0.13 % 0.12 % 0.24 % 0.23 % 0.21 % 0.19 % 0.22 % 0.21 % 0.23 % 0.13 % Fluke 5520A
43--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 43 of 52 Parameter/Equipment Range CMC2, 7 (±) Comments Phase Angle3 – Measure (0 to 359.9999) ° Generate (0 to 359.99) ° 10 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 200) kHz (10 to 65) Hz (65 to 500) Hz (0.5 to 1) kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.012° 0.017° 0.051° 0.11° 0.11° 0.26° 0.50° 2.5° 5.0° 10° North Atlantic PAV 2250A Fluke 5520A Inductance3 – Measure Generate Fixed points Variable (0.1 to 10) µH (0.01 to 10) mH 0.01 to 100) mH (0.1 to 10) H (10 to 100) H 20 mH 100 mH 200 mH 2 H (1 to 10) mH (10 to 100) mH (0.1 to 1) H (1 to 10) H 0.022 µH 0.21 µH 0.02 H 6.4 H 0.61 H 0.012 mH 0.054 mH 0.12 mH 1.3 mH 9.5 µH 0.81 mH 0.011 H 0.2 H HP 4284A General radio 1482 series inductors General radio 1490D Dissipation Factor – Measure (Df)3 1 pF to 100 µF (0.0001 to 10) Df 3.5 % + 1 cts Multi-frequency LCR Meter cts: Counts of LSD
0 to 359.9999 °
44

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 44 of 52 Parameter/Equipment Range CMC2, 7 (±) Comments Capacitance3 – Measure Generate (0 to 1) nF (0.001 to 10) µF (0.001 to 10) mF (0.01 to 110) mF (0.19 to 0.4) nF (0.4 to 1.1) nF (1.2 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1.2 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.2 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 100) mF 1.1 pF 5.4 nF 0.011 mF 0.28 mF 0.26 % + 13 pF 0.56 % + 12 pF 0.27 % + 13 pF 0.29 % + 120 pF 0.27 % + 140 pF 0.27 % + 390 pF 0.27 % + 1.3 nF 0.27 % + 3.9 nF 0.25 % + 15 nF 0.26 % + 42 nF 0.38 % + 170 nF 0.45 % + 480 nF 0.50 % + 1.4 µF 0.44 % + 4.9 µF 0.26 % + 36 µF 0.78 % + 49 µF 0.83 % + 360 µF 1.1 % + 360 µF HP 4284A Fluke 5520A Capacitance3 – Fixed 1 nF 2 nF 10 nF 100 nF 200 nF 1 µF 0.50 pF 1.1 pF 5.4 pF 7.4 pF 0.10 nF 0.19 nF General radio 1409 series standard capacitors
45

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 45 of 52 Parameter/Equipment Range CMC2, 12 (±) Comments Thermocouple Indicating - Simulation3 Type C Type E Type J Type K Type N Type R Type S Type T (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -30) °C (-30 to 50) °C (50 to 500) °C (500 to 1200) °C (-200 to -100) °C (-100 to -30) °C (-30 to 120) °C (120 to 1050) °C (1050 to 1371.1) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to -100) °C (-100 to 0) °C (0 to 400) °C 0.35 °C 0.28 °C 0.33 °C 0.52 °C 0.87 °C 0.58 °C 0.20 °C 0.18 °C 0.20 °C 0.26 °C 0.30 °C 0.29 °C 0.16 °C 0.23 °C 0.35 °C 0.19 °C 0.17 °C 0.15 °C 0.23 °C 0.42 °C 0.24 °C 0.21 °C 0.20 °C 0.28 °C 0.62 °C 0.41 °C 0.37 °C 0.43 °C 0.53 °C 0.41 °C 0.41 °C 0.49 °C 0.64 °C 0.26 °C 0.18 °C 0.15 °C Fluke 5520A
46

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 46 of 52 Parameter/Equipment Range CMC2, 12 (±) Comments RTD Simulation3 Cu427 Ni120 Pt 385, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω Pt 3916, 100 Ω Pt 3926, 100 Ω 100 to 260 °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 600) °C (600 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C 0.34 °C 0.085 °C 0.084 °C 0.15 °C 0.090 °C 0.093 °C 0.11 °C 0.13 °C 0.14 °C 0.15 °C 0.25 °C 0.046 °C 0.055 °C 0.13 °C 0.14 °C 0.15 °C 0.17 °C 0.042 °C 0.051 °C 0.061 °C 0.081 °C 0.092 °C 0.12 °C 0.031 °C 0.041 °C 0.052 °C 0.062 °C 0.072 °C 0.23 °C 0.28 °C 0.058 °C 0.067 °C 0.075 °C 0.093 °C 0.11 °C 0.11 °C 0.12 °C 0.24 °C 0.066 °C 0.083 °C 0.11 °C 0.12 °C 0.14 °C Fluke 5520A
47

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 47 of 52 Parameter/Equipment Range CMC2 (±) Comments Oscilloscopes – Amplitude – DC Signal3 50 Ω Load 1 MΩ Load Amplitude – Square Wave 50 Ω Load 1 MΩ Load (0 to 6) V (0 to 130) V 1 mV p-p to 6.6 Vp-p; 10 Hz to 10 kHz 1 mV p-p to 130 Vp-p; 10 Hz to 10 kHz 29 mV/V + 0.58 mV 590 µV/V + 75 µV 29 mV p-p/Vp-p + 75 µVp-p 280 µV p-p/Vp-p + 75 µVp-p 5520A-SC1100 multifunction calibrator w/ oscilloscope opt Oscilloscopes – Rise Time 0.001 to 2 MHz 2 to 10 MHz (200 to 300) ps (250 to 350) ps 120 ps 140 ps 5520A-SC1100 multifunction calibrator w/ oscilloscope opt Oscilloscopes – Bandwidth3 5 mV to 5.5 Vp-p 4 mV to 3.5 V p-p Leveled Sine Wave – Frequency Time Marker 50 kHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 kHz to 1.1 GHz 2 ns to 20 ms 50 ms to 5 s 58 mVp-p/Vp-p + 470 µVp-p 58 mVp-p/Vp-p + 470 µVp-p 70 mVp-p/Vp-p + 470 µVp-p 120 mVp-p/Vp-p + 470 µVp-p 140 mVp-p/Vp-p + 470 µVp-p 0.58 kHz 2.9 µs/s + 0.15 ps 1.2 ms/s + 58 µs 5520A-SC1100 multifunction calibrator w/ oscilloscope opt
48

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 48 of 52 Parameter/Equipment Range CMC2 (±) Comments Oscilloscopes – Wave Functions - Square, Sine, &Triangle3 50 Ω Load 1 MΩ Load Pulse Characteristics3 – Pulse Width Pulse Period Rise Time – Generate 1.8 mV p-p to 2.5 Vp-p. 10 Hz to 10 kHz 1.8 mVp-p to 55 Vp-p. 10 Hz to 10 kHz (4 to 500) ns 200 ns to 20 ms 1 kHz to 2 MHz (200 to 300) ps 3 to 10 MHz (200 to 350) ps 35 mV p-p/Vp-p + 120 µVp-p 35 mVp-p/Vp-p + 120 µVp-p 2.6 ns 150 ps 120 ps 120 ps 5520A-SC1100 multifunction calibrator w/ oscilloscope opt. IV. Electrical – RF/Microwave Parameter/Range Frequency CMC2, 7 (±) Comments Total Harmonic Distortion3 47 Hz to 100 kHz 1.7 % North Atlantic PAV 2250A VI. Mechanical Parameter/Equipment Frequency CMC2, 6 (±) Comments Accelerometers3 Voltage Sensitivity (up to 1000) mv/g’s 50 Hz to 2 kHz (2 to 10) kHz 3.5 % 5.0 % Modal Shop 9100D Portable
49

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 49 of 52 Parameter/Range Range CMC2, 7 (±) Comments Scales & Balances3 – Linearity Only (1.0 to 2.0) lbf (2.0 to 5.0) lbf (5.0 to 10.0) lbf (10.0 to 20.0) lbf (20.0 to 100.0) lbf (100.0 to 200.0) lbf (1 to 50) mg (50 to 500) mg (0.5 to 1) g (1 to 5) g (5 to 50) g (50 to 100) g (100 to 200) g (200 to 2000) g (2000 to 6000) g 1.1 x 10-3 lbf 2.0 x 10-3 lbf 3.5 x 10-3 lbf 2.6 x 10-3 lbf 9.2 x 10-3 lbf 1.6 x 10-2 lbf 0.017 mg 0.027 mg 0.055 mg 0.055 mg 0.16 mg 0.64 mg 0.77 mg 6.9 mg 0.14 g Reference Weights Class 1 weights Force – Measuring Equipment3 (1 to 100) lb 0.052 % Class F weights Pneumatic Pressure – Measuring Equipment 3 Compressed Air3 Pressure Up to 15 psi (15 to 30) psi Up to 45 psi (45 to 90) psi Up to 150 psi (150 to 300) psi Up to 500 psi (500 to 1000) psi Up to 1500 psi (1500 to 3000) psi (3000 to 6000) psi (6000 to 10 000) psi 0.0015 psi 0.003 psi 0.0046 psi 0.0091 psi 0.015 psi 0.030 psi 0.051 psi 0.10 psi 0.15 psi 0.31 psi 8.6 psi 9.5 psi Fluke 6270 Fluke PM500 Fluke 700P31
50DOC-00196-30 to 250000 rpm
51

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 51 of 52 Parameter/Equipment Range CMC2, 8 (±) Comments Infrared – Measure3 (30 to 100) °C (100 to 150) °C (150 to 200) °C (200 to 250) °C (160 to 500) °C (500 to 900) °C (900 to 1300) °C (1300 to 1650) °C 2.4 °C 3.5 °C 4.7 °C 6 °C 3 °C 4 °C 5 °C 5 °C Infrared camera Fluke VT04 wavelength (6.5 to 14) µm emissivity 0.01 to 1.0 Infrared camera Williamson SW-22- 45C-FOV wavelength (2.2) µm emissivity 0.01 to 1.5 Temperature – Measure (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 420) °C (420 to 500) °C 0.084 °C 0.031 °C 0.033 °C 0.066 °C 0.078 °C Fluke 5615-9 probe, Fluke 1524 reference thermometer Burns 12005 VI. Time & Frequency Parameter/Equipment Range CMC2, 8 (±) Comments Frequency3 – Measure 1 mHz to 3 GHz (3 to 20) GHz 30 nHz/Hz 46 nHz/Hz Agilent 53132A Agilent 53147A Timers/Stopwatches3 Up to 24 hr. 0.065 s/day Timometer 4500 __________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
52

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2147.01) Revised 08/29/2024 Page 52 of 52 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 Specifications are typical below 10 MHz. 5 Relative to +16 dBm output. 6 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches; R is instrument resolution; D is diagonal length; S is each segment greater than the first 36 inch segment; percentages are percentage of reading, unless otherwise indicated. 7 The measurands stated are generated using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 Adjustable thread rings are set to applicable specifications using calibrated master set plug gages. 10 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 11 This scope meets A2LA’s P112 Flexible Scope Policy. 12 Simulation is measuring equipment and measure.
53ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3120 Independence Dr., Fort Wayne, IN, 46808, US

41.07999, -85.13860

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.