PRECISION REPAIR AND CALIBRATIONS
10370 Flanders Street NE, 55449, Blaine, MN, United States
Visit website- Scope lines
- 25
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 25 scope lines.
A2LA certificate 5428.01 · 25 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 60 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 2 of 24
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Height Masters
Up to 18 in
(9 + 7.4L) µin
9
Electronic indicator, gage
blocks, surface plate
Indicators
3
Up to 5 in
(24 + 29L) µin9
Grade 2 gage blocks,
micrometer head
Ring Gages – Inside
Dimension
Up to 11 in
13 µin
Universal measuring
machine, master rings
Laser Micrometer3
Up to 2 in
14 µin
Master pin gages
Length Standards
Up to 36 in
(34 + 6.2L) µin
Universal measuring
machine, gage blocks,
bench micrometer
Micrometers (OD)
3
Up to 36 in
(12 + 7.9L) µin9
Grade 2 gage blocks
Micrometers (ID)
3
Up to 40 in
(34 + 6.2L) µin9
Gage blocks, bench
micrometer, universal
measuring machine
Micrometers – Depth
3
Up to 12 in
(520 + 1.1L) µin
Mike master, gage blocks
Micrometer Heads
Up to 2 in
44 µin
9
Gage blocks, electronic
indicator, optical flat,
universal measuring
machine
Mike Masters
Up to 6 in
61 µin
Gage blocks, surface plate,
electronic indicator
Pin Gages (OD)
3
Up to 1 in
15 µin
Master pin gage, laser
micrometer | to 18 in |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 3 of 24
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Plug Gages (OD)
3
Up to 20 in
(16 + 1.1L) µin
Universal measuring
machine, grade 2 gage
blocks
Bore Gages
3
Up to 12 in
(210 + 19L) µin
Gage blocks, gage block
accessory, master ring
gages
Optical Comparators3
Up to 12 in Linearity
Magnification
100 µin
53 µin
Glass scales, precision balls
Microscopes
3
Up to 12 in Linearity
Magnification
100 µin
53 µin
Gage blocks, glass scales
VMMs
3
Up to 12 in Linearity
Magnification
110 µin
180 µin
Glass scales, laser
Master Setting Disc
Up to 20 in
(16 + 1.1L) µin
Gage blocks, universal
measuring machine
Precision Balls
Up to 2 in
22 µin
Universal measuring
machine
Snap Gages3
Up to 4 in
160 µin
Gage blocks
Surface Plates –
Overall Flatness3
Local Area Flatness
3
(repeat reading)
Up to 16 ft diagonal
Up to 16 ft diagonal
57 µin
22 µin
Precision levels
Repeat-o-meter
Thread Plug Gages –
Thread Set Plugs
3
Up to 10 in
85 µin
Bench micrometer, grade 2
gage blocks, thread
measuring wires | to 20 in |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 4 of 24
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Thread Ring Gages
Pitch Diameter:
Up to 10 in
Minor Diameter:
Up to 0.500 in
(0.500 to 10.00) in
100 µin
110 µin
51 µin
Thread set plug masters
VMM
ULM
Tapered Thread Plug
Gages
Up to 7 in
520 µin Basic
190 µin PD
Thread measuring wires,
bench micrometer,
O.D. micrometer
Tapered Thread Ring
Gages, Crest Check
Up to 7 in
520 µin Basic
520 µin Standoff
Master tapered thread
plugs, O.D. micrometer
Rulers
Up to 72 in
(1500 + 1.8L) µin
Microscope, gage blocks
Rulers
3
Up to 72 in
(880 + 8.5L) µin
Gage blocks
Tape Measures
3
Up to 600 in
4800 µin9
Gage blocks
Angle Blocks
Up to 45°
64 µin
Gage blocks, sine bar,
indicator, surface plate
Angle Leaf
Up to 12 in
(250 + 1.7L) µin
VMM
1–2–3 Blocks
Up to 6 in
35 µin
Gage blocks, surface plate,
indicator
Radius Gages
Up to 12 in
(250 + 1.7L) µin
VMM | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 5 of 24
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
V–Blocks
Up to 6 in
110 µin
Pin gages, surface plate,
indicator
Parallels &
Straight Edges
3
Up to 48 in
57 µin
Gage blocks, indicator
surface plate
Steel Squares
Up to 18 in
(26 + 6.5L) µin
Surface plate, indicator,
master square
Feeler Gages
Up to 0.5 in
93 µin
Gage blocks, super
micrometer
Comptor Gage Indicators
Up to 0.04 in
200 µin
Comptor master
Profilometers
3
Up to 250 µin
6.4 µin
Profilometer standard
Protractors
(0 to 360)°
0.12°
Angle blocks, surface
plate, master square
Chamfer Gages3
Up to 3 in
99 µin9
Chamfer checker gage
II. Dimensional Testing/Calibration
8
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Dimensional Measurement
Up to 6 in
Up to 20 in
Up to 18 in
Up to 1 in
Up to 12 in
(71 + 33L) µin
9
44 µin
(9.1 + 7.4L) µin
(12 + 7.9L) µin
9
(250 + 1.7L) µin
Caliper
Bench micrometer
Indicator
Micrometer
VMM | 0 to 360 ° |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 6 of 24
III. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Voltage – Generate
3
Up to 330 mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
100 V to 1 kV
1 µV + 16 µV/V
6 µV + 9 µV/V
60 µV + 10 µV/V
0.59 mV + 14 µV/V
5.9 mV + 14 µV/V
Fluke 5522A multi
product calibrator
DC Voltage – Measure
3
Up to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
100 V to 1 kV
(1 to 6) kV
(6 to 20) kV
(20 to 35) kV
@ (20 to 30) °C
(35 to 40) kV
0.64 µV
3.9 µV
31 μV
0.55 mV
5.3 mV
1.1 mV/V + 2.3 V
2.3 mV/V + 220 mV
1.2 mV/V + 160 mV
2.3 mV/V + 67 mV
HP 3458A Opt 002
multimeter
Fluke 187 w/
Fluke 80K6 probe
Fluke 187 w/
Fluke 80K40 probe
DC Current – Generate3
Up to 330 μA
330 μA to 3.3 mA
(3.3 to 33) mA
(33 to 330) mA
330 mA to 1.1 A
(1.1 to 3) A
(3 to 11) A
(11 to 20) A
20 nA + 0.12 mA/A
0.25 μA + 78 μA/A
0.61 μA + 78 μA/A
6.1 μA + 78 μA/A
66 μA + 0.16 mA/A
66 μA + 0.3 mA/A
0.70 mA + 0.39 mA/A
0.82 mA + 0.78 mA/A
Fluke 5522A multi
product calibrator
DC Current – Measure3
Up to 100 nA
100 nA to 1 μA
(1 to 10) μA
(10 to 100) μA
100 μA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 1200) A
40 pA + 35 μA/A
40 pA + 25 μA/A
0.1 nA + 25 μA/A
0.8 nA + 25 μA/A
5 nA + 25 μA/A
50 nA + 25 μA/A
0.5 μA + 40 μA/A
10 μA + 0.12 mA/A
2.3 mA + 2.5 mA/A
HP 3458A opt 002
multimeter
HP 3458A
multimeter w/
current shunts
Empro B-1200-100 | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 7 of 24
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Power – Generate
3
33 mV to 1.02 kV:
(0.33 to 329.99) mA
(0.33 to 2.9999) A
(3 to 20.5) A
0.01 µW to 337 W
(0.01 to 3060) W
(3.06 to 20.91) kW
5.8 µW + 240 µW/W
4 µW + 240 µW/W
5.4 µW + 690 µW/W
Fluke 5522A multi
product calibrator
Capacitance
3 – Generate
(220 to 399.9) pF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 32.9999) nF
(33 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) μF
(1.1 to 3.299 99) μF
(3.3 to 10.9999) μF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
0.43 % nominal + 12 pF
0.44 % nominal + 12 pF
0.45 % nominal + 12 pF
0.22 % nominal + 12 pF
0.23 % nominal + 12 pF
0.23 % nominal + 12 pF
0.26 % nominal + 360 pF
0.23 % nominal + 1.2 nF
0.28 % nominal + 2.9 nF
0.25 % nominal + 11 nF
0.43 % nominal + 28 nF
0.44 % nominal + 110 nF
0.45 % nominal + 320 nF
0.39 % nominal + 1.3 µF
0.54 % nominal + 1.9 µF
0.52 % nominal + 9.9 µF
0.87 % nominal + 36 µF
1.2 % nominal + 94 µF
Fluke 5522A multi
product calibrator
Resistance
3 – Generate
Up to 10.9999 Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(330 to 1099.999) Ω
(1.1 to 3.299 999) kΩ
(3.3 to 10.999 99) kΩ
(11 to 32.999 99) kΩ
(33 to 109.9999) kΩ
(110 to 329.9999) kΩ
(.330 to 1.099 999) MΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
110 μΩ/Ω + 140 μΩ
30 μΩ/Ω + 63 μΩ
25 μΩ/Ω + 110 μΩ
26 μΩ/Ω + 38μΩ
26 μΩ/Ω + 7.7 μΩ
25 μΩ/Ω + 58μΩ
84 μΩ/Ω + 5.8mΩ
2.6 mΩ/Ω + 5.8mΩ
1.0 mΩ/Ω + 58mΩ
3 mΩ/Ω + 81 mΩ
33 mΩ/Ω + 830 mΩ
36 mΩ/Ω + 810 mΩ
41 mΩ/Ω + 810 mΩ
480 mΩ/Ω + 5.8 Ω
560 mΩ/Ω + 12 Ω
780 mΩ/Ω + 12 Ω
1.4 Ω/Ω + 57 Ω
Fluke 5522A multi
product calibrator | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 8 of 24
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance
3 – Measure
Up to 10 Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
100 MΩ to 1 GΩ
58 μΩ + 10 μΩ/Ω
58 μΩ + 12 μΩ/Ω
0.58 mΩ + 10 μΩ/Ω
5.8 mΩ + 10 μΩ/Ω
57 mΩ + 10 μΩ/Ω
0.58 Ω + 10 μΩ/Ω
5.8 Ω + 50 μΩ/Ω
58 mΩ + 0.5 mΩ/Ω
0.58 Ω + 5 mΩ/Ω
HP 3458A opt 002
multimeter
Electrical Simulation of
Thermocouple
Indicators
3
Type B
Type C
Type E
Type J
Type K
Type L
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(0 to 150) °C
(150 to 600) °C
(650 to 1000) °C
(1000 to 1800) °C
(1800 to 2316) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to 800) °C
(800 to 900) °C
0.42 °C
0.35 °C
0.31 °C
0.27 °C
0.24 °C
0.20 °C
0.24 °C
0.39 °C
0.64 °C
0.38 °C
0.13 °C
0.11 °C
0.13 °C
0.17 °C
0.21 °C
0.13 °C
0.11 °C
0.14 °C
0.19 °C
0.26 °C
0.15 °C
0.13 °C
0.20 °C
0.31 °C
0.37 °C
0.27 °C
0.18 °C
Fluke 5522A-600
multi product
calibrator | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 9 of 24
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouple
Indicators
3 (cont)
Type N
Type R
Type S
Type T
Type U
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
(-200 to 0) °C
(0 to 600) °C
0.31 °C
0.18 °C
0.16 °C
0.16 °C
0.23 °C
0.48 °C
0.29 °C
0.27 °C
0.31 °C
0.48 °C
0.31 °C
0.29 °C
0.35 °C
0.48 °C
0.19 °C
0.13 °C
0.11 °C
0.56 °C
0.28 °C
Fluke 5522A-600
multi product
calibrator
Electrical Simulation of
RTD Indicators
3 –
Pt 385, 100 Ω
Pt 3926, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
0.04 °C
0.05 °C
0.07 °C
0.07 °C
0.09 °C
0.09 °C
0.21 °C
0.04 °C
0.05 °C
0.07 °C
0.08 °C
0.09 °C
0.10 °C
Fluke 5522A multi
product calibrator | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 10 of 24
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
RTD Indicators
3 – (cont)
Pt 3916, 100 Ω
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
PtNi 385, 120 Ω
Cu 427, 10 Ω
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-200 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(-100 to 260) °C
0.25 °C
0.04 °C
0.05 °C
0.06 °C
0.06 °C
0.07 °C
0.08 °C
0.08 °C
0.21 °C
0.03 °C
0.03 °C
0.04 °C
0.04 °C
0.11 °C
0.12 °C
0.12 °C
0.14 °C
0.03 °C
0.04 °C
0.05 °C
0.06 °C
0.07 °C
0.07 °C
0.08 °C
0.09 °C
0.03 °C
0.03 °C
0.03 °C
0.05 °C
0.06 °C
0.06 °C
0.07 °C
0.22 °C
0.06 °C
0.07 °C
0.13 °C
0.30 °C
Fluke 5522A multi
product calibrator | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 11 of 24
Parameter/Range
Frequency
CMC2 (±)
Comments
AC Voltage – Generate
3
(1 to 33) mV
(33 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
330 V to 1 kV
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
7.4 μV + 0.62 mV/V
7.4 μV + 0.12 mV/V
7.4 μV + 0.16 mV/V
7.4 μV + 0.78 mV/V
10 μV + 2.7 mV/V
39 μV + 6.2 mV/V
8.5 μV + 0.39 mV/V
8.5 μV + 0.11 mV/V
8.5 μV + 0.13 mV/V
8.5 μV + 0.27 mV/V
26 μV + 0.62 mV/V
55 μV + 1.5 mV/V
3.4 mV + 0.23 mV/V
4.1 mV + 0.12 mV/V
0.18 mV + 0.15 mV/V
0.18 mV + 0.23 mV/V
0.2 mV + 0.55 mV/V
0.5 mV + 1.9 mV/V
0.77 mV + 0.23 mV/V
0.74 mV + 0.12 mV/V
0.74 mV + 0.19 mV/V
0.74 mV + 0.27 mV/V
1.4 mV + 0.7 mV/V
6 mV + 0.15 mV/V
7.4 mV + 0.16 mV/V
7.4 mV + 0.2 mV/V
7.4 mV + 0.23 mV/V
39 mV + 1.6 mV/V
58 mV + 0.23 mV/V
58 μV + 0.2 mV/V
59 mV + 0.23 mV/V
Fluke 5522A multi
product calibrator
AC Voltage – Measure
3
(1 to 10) mV
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 250) kHz
350 μV/V + 3.5 μV
230 μV/V + 13 μV
350 μV/V + 13 μV
1.2 mV/V + 13 μV
5.8 mV/V + 13 μV
46 mV/V + 23 μV
HP 3458A Opt 002
multimeter | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 12 of 24
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure
3
(cont)
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
100 V to 1 kV
(1 to 6) kV
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
DC to 1 kHz
4.1 µV/V + 180 μV
7.5 µV/V + 31 μV
16 µV/V + 29 μV
34 µV/V + 28 μV
92 µV/V + 25 μV
3.5 mV/V + 120 μV
1.2 mV/V + 120 μV
1.7 mV/V + 40 μV
4 µV/V + 180 μV
7.9 µV/V + 25 μV
160 µV/V + 26 μV
340 µV/V + 26 μV
920 µV/V + 25 μV
3.5 mV/V + 120 μV
12 mV/V + 140 μV
17 mV/V + 400 μV
79 µV/V + 500 μV
79 µV/V + 260 μV
160 µV/V + 260 μV
340 µV/V + 270 μV
920 µV/V + 250 μ
V
4.1 mV/V + 180 μV
120 mV/V + 1.5 mV
120 mV/V + 1.5 mV
230 µV/V + 4.8 mV
230 µV/V + 2.5 mV
230 µV/V + 2.6 mV
400 µV/V + 2.7 mV
1.4 mV/V + 2.6 mV
4.6 mV/V + 12 mV
17 mV/V + 12 mV
460 µV/V + 47 mV
460 µV/V + 24 mV
690 µV/V + 24 mV
1.4 mV/V + 24 mV
3.5 mV/V + 23 mV
2.6 V + 4.3 mV/V
HP 3458A opt 002
multimeter
Fluke 187 w/
Fluke 80K6 probe | ||
| 13 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 13 of 24
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure3
(cont)
(6 to 40) kV
60 Hz
58 V + 4.6 mV/V
Fluke 187 w/
Fluke 80K40 probe
AC Current – Generate
3
(29 to 329.99) μA
(0.33 to 3.299 99) mA
(3.3 to 32.9999) mA
(33 to 329.999) mA
(0.33 to 2.999 99) A
(3 to 10.9999) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
45 Hz to 1 kHz
(1 to 5) kHz
0.12 μA + 1.9 nA/A
0.12 μA + 1.4 nA/A
0.12 μA + 1.2 nA/A
0.17 μA + 2.9 nA/A
0.23 μA + 6.9 nA/A
0.46 μA + 14 nA/A
170 nA + 1.8 µA/A
170 nA + 1.2 µA/A
170 nA + 920 nA/A
230 nA + 1.8 µA/A
350 nA + 4.6 µA/A
690 nA + 9.2 µA/A
2.3 µA + 1.7 µA/A
2.3 µA + 420 nA/A
2.3 μA + 760 nA/A
3.5 μA + 1.9 µA/A
4.6 μA + 3.7 µA/A
23 μA + 1.7 µA/A
23 μA + 420 nA/A
57 μA + 950 nA/A
110 μA + 2 µA/A
230 µA + 3.8 µA/A
110 µA + 1.8 mA/A
91 μA + 660 µA/A
110 mA + 5.9 mA/A
5.8 mA + 23 mA/A
2.4 mA + 580 µA/A
2.4 mA + 920 µA/A
2.4 mA + 29 mA/A
5.7 mA + 1.5 mA/A
5.8 mA + 29 mA/A
Fluke 5522A multi
product calibrator | 6 to 40 kV |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 14 of 24
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate
3
(cont)
(20 to 150) A
(150 to 550) A
(550 to 1000) A
45 Hz to 1 kHz
(45 to 440) Hz
(45 to 440) Hz
87 μA + 5000 μA/A
1600 μA + 5000 μA/A
3900 μA + 5000 μA/A
Fluke 5522A-600
multi product
calibrator
W/5500/Coil
AC Current – Measure3
Up to 100 μA
100 μA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 1200) A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
1 Hz to 2 MHz
35 nA + 4.6 nA/A
35 nA + 1.7 nA/A
35 nA + 690 pA/A
35 nA + 690 pA/A
28 nA + 4.9 µA/A
6.6 nA + 2 µA/A
12 nA + 1.1 µA/A
16 nA + 8 µA/A
12 nA + 1.1 µA/A
27 nA + 5.1 µA/A
17 nA + 8.1 µA/A
2.3 µA + 4.6 µA/A
2.3 µA + 1.7 µA/A
2.3 µA + 690 nA/A
2.3 µA + 350 nA/A
2.3 µA + 690 nA/A
4.6 µA + 4.6 µA/A
17 µA + 6.4 µA/A
25 µA + 4.4 µA/A
25 µA + 1.5 µA/A
25 µA + 460 nA/A
25 µA + 120 nA/A
25 µA + 460 nA/A
51 µA + 4.2 µA/A
190 µA + 4.6 µA/A
230 µA + 4.6 µA/A
230 µA + 1.8 µA/A
230 µA + 920 nA/A
230 µA + 1.2 µA/A
230 µA + 3.5 µA/A
460 µA + 12 µA/A
1.4A + 490 µA/A
HP 3458A opt 002
multimeter
HP 3458A
multimeter opt 002
w/ current shunt
Empro B-1200-100 | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 15 of 24
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
AC Power – Generate
3
(33 to 329.99) mV
(3.3 to 329.99) mA
(0.33 to 2.1999) A
(2.2 to 20.5) A
0.1 µW to 108 mW
(109 to 725) mW
726 mW to 6.76 W
180 μW + 1.5 mW/W
160 μW + 8.6 mW/W
160 µW + 1.5 mW/W
Fluke 5522A multi
product calibrator
AC Power – Generate3
(0.33 to 1020) V
(3.3 to 329.99) mA
(0.33 to 2.1999) A
(2.2 to 20.5) A
1 mW to 336 W
110 mW to 2243 W
726 mW to 20 910 W
180 µW + 1.4 mW/W
84 µW + 1.4 mW/W
160 µW + 1.4 mW/W
Fluke 5522A multi
product calibrator
Oscilloscopes3 –
DC Signal
Into 50 Ω
Into 1 MΩ
Square Wave Signal
Into 50 Ω
Into 1 MΩ
Leveled Sine Wave
Amplitude
5 mV to 5.5 V
Leveled Sine Wave
Flatness (relative to 50
kHz)
5 mV to 5.5 V
Time Marker 50 Ω
Source & Period
Rise Time
0 mV to 6.6 V
0 mV to 130 V
1 mV to 6.6 V
p-p
10 Hz to 10 kHz
1 mV to 130 V
p-p
10 Hz to 10 kHz
50 kHz reference
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
5 s to 50 ms
20 ms to 2 ns
(200 to 350) ps
1 kHz to 10 MHz
200 µV/V + 2 mV
330 µV/V + 2 mV
2 mV/V + 30 μV
0.76 mV/V + 30 mV
16 mV/V + 0.23 mV
27 mV/V + 0.23mV
31 mV/V + 0.23 mV
47 mV/V + 0.23 mV
12 mV/V + 78 μV
16 mV/V + 78 μV
31 mV/V + 78 μV
19 μs/s + 54 μs
1.9 μs/s
78 ps
Fluke 5522A SC600
multi product
calibrator | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 16 of 24
IV. Electrical – RF/Microwave
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
RF Power – Measure
(20 to 30) dBm
(0 to 20) dBm
(-5 to 0) dBm
(-10 to -5) dBm
(-136 to 20) dBm
30 MHz to 2 GHz
(2 to 4.2) GHz
(4.2 to 18) GHz
(18 to 26.5) GHz
30 MHz to 2 GHz
(2 to 4.2) GHz
(4.2 to 18) GHz
(18 to 26.5) GHz
30 MHz to 2 GHz
(2 to 4.2) GHz
(4.2 to 18) GHz
(18 to 26.5) GHz
30 MHz to 2 GHz
(2 to 4.2) GHz
(4.2 to 18) GHz
(18 to 26.5) GHz
100 Hz to 26.5 GHz
0.33 dB
0.34 dB
0.51 dB
0.43 dB
0.26 dB
0.28 dB
0.47 dB
0.38 dB
0.26 dB
0.28 dB
0.47 dB
0.38 dB
0.27 dB
0.29 dB
0.48 dB
0.39 dB
0.67 dB
N5531X Measuring
receiver (includes
N9030B,
N9091EMOE,
N1913A, N5532B)
RF Power – Generate
(-100 to +24) dB
(-100 to +20) dB
(-100 to +18) dB
1 mHz to 4 GHz
(1.4 to 20) GHz
(20 to 26.5) GHz
0.70 dB
1.3 dB
1.7 dB
96270A Leveled
microwave output | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 17 of 24
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Level Sine Wave –
Generate
(-130 to -94) dBm
(-94 to -84) dBm
(-84 to -74) dBm
(-74 to -48) dBm
(-48 to -17) dBm
(-17 to +14) dBm
(+14 to +20) dBm
(+20 to +24) dBm
(10 to 128) MHz
128 MHz to 3 GHz
100 kHz to 10 MHz
(10 to 128) MHz
(128 to 300) MHz
300 MHz to 3 GHz
100 kHz to 10 MHz
(10 to 128) MHz
(128 to 300) MHz
300 MHz to 1.4 GHz
(1.4 to 4) GHz
100 kHz to 100 MHz
(10 to 300) MHz
300 MHz to 1.4 GHz
(1.4 to 4) GHz
10 Hz to 100 kHz
100 kHz to 128 MHz
(128 to 300) MHz
300 MHz to 1.4 GHz
(1.4 to 3) GHz
(3 to 4) GHz
10 Hz to 100 kHz
100 kHz to 128 MHz
(128 to 300) MHz
300 MHz to 1.4 GHz
(1.4 to 4) GHz
10 Hz to 100 kHz
100 kHz to 128 MHz
(128 to 300) MHz
300 MHz to 1.4 GHz
10 Hz to 100 kHz
100 kHz to 128 MHz
0.87 dB
1.7 dB
0.67 dB
0.47 dB
0.67 dB
1.2 dB
0.67 dB
0.27 dB
0.47 dB
0.67 dB
1.2 dB
0.37 dB
0.27 dB
0.57 dB
0.67 dB
0.20 dB
0.22 dB
0.24 dB
0.37 dB
0.47 dB
0.67 dB
0.20 dB
0.22 dB
0.24 dB
0.37 dB
0.47 dB
0.20 dB
0.22 dB
0.24 dB
0.37 dB
0.20 dB
0.22 dB
96270A w/ 96040A-
50
Level Sine Wave –
Microwave Output
(-100 to +24) dBm
10 Hz to 4 GHz
(4 to 26.5) GHZ
0.5 dB
1.0 dB
96270A Phase noise
reference source | ||
| 18 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 18 of 24
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Attenuation – Measure
10 Hz to 128 MHz
(0 to 55) dB
(55 to 64) dB
(64 to 74) dB
(74 to 100) dB
(100 to 116) dB
0.08 dB
0.09 dB
0.11 dB
0.13 dB
0.21 dB
96270A w/ N9030A
& NRP-Z55.03
Amplitude Modulation –
Measure
(Carrier: 2 Hz to 26.5
GHz)
(Carrier: 10 MHz to
26.5 GHz; Rate: 38 Hz
to 243 kHz)
Depth: (5 to 99) %
Depth: (5 to 99) %
2.0 %
2.0 %
N9030B PXA
Signal analyzer
Amplitude Modulation –
Generate
(Carrier: 50 kHz to 4
GHz; Rate: 1 Hz to
100 kHz)
Depth: (5 to 10) %
Depth: ( 10 to 99) %
3.3 %
3.9 %
96270A with
96040A-50
Frequency Modulation –
Measure
(Carrier: 2 Hz to 26.5
GHz; Rate: 1 Hz to
12.5 MHz)
(Carrier: 10 MHz to
26.5 GHz; Rate: 10 Hz
to 1 MHz)
Deviation: Up to 10
MHz
Deviation: Up to 10
MHz
300 mHz/Hz + 1.4 Hz
300 mHz/Hz + 1.4 Hz
N5531X Measuring
receiver
Frequency Modulation –
Generate
(Carrier: 9 MHz to
31.25 MHz; Rate: 1
Hz to 50 kHz)
Deviation: 10 Hz to
300 kHz
130 mHz/Hz
96270A w/
96040A-50 | to 128 MHz |
| 19 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 19 of 24
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Frequency Modulation –
Generate (cont)
(Carrier: 31.25 MHz to
125 MHz; Rate: 50
kHz to 300 kHz)
Deviation: 10 Hz to
300 kHz
310 mHz/Hz
96270A w/96040A-
50
Frequency Modulation –
Generate (cont)
(Carrier: 31.25 MHz to
125 MHz; Rate: 1 Hz
to 50 kHz)
(Carrier: 31.25 MHz to
125 MHz; Rate: 50
kHz to 300 kHz)
(Carrier: 125 MHz to 4
GHz; Rate: 1 Hz to 50
kHz)
(Carrier: 125 MHz to 4
GHz; Rate: 50 kHz to
300 kHz)
Deviation: 10 Hz to
750 kHz
Deviation: 10 Hz to
750 kHz
Deviation: 10 Hz to
4.8 MHz
Deviation: 10 Hz to
4.8 MHz
130 mHz/Hz
310 mHz/Hz
130 mHz/Hz
310 mHz/Hz
96270A w/96040A-
50
Phase Modulation –
Measure
(Carrier: 2 Hz to 26.5
GHz; Rate: 50 Hz to
100 kHz)
(Carrier: 10 MHz to
26.5 GHz; Rate: 100
kHz to 1 MHz)
Deviation:
(0.01 to 25 000) rad
Deviation:
(0.01 to 25 000) rad
7.9 x 10
-3 rad/rad
7.9 x 10
-3 rad/rad
N5531X Measuring
receiver | to 4.8 MHz |
| 20 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 20 of 24
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Phase Modulation –
Generate
(Carrier: 9 MHz to 4
GHz; Rate: 1 Hz to 50
kHz)
(Carrier: 9 MHz to 4
GHz; Rate: 1 Hz to 50
kHz)
Deviation: Up to 1000
rad
Deviation: Up to 1000
rad
3.0 x 10
-3 rad/rad
3.0 x 10
-3 rad/rad
96270A Phase noise
reference source 41
V. Mechanical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Force Gage
3
(Tension &
Compression)
Up to 10 lb
(10 to 110) lb
(110 to 500) lb
0.05 lb
0.15 lb
0.46 lb
Test weights
Laboratory Balance3
Up to 6000 g
(0.01 + 0.000 000 14W) mg
Weight kit
Industrial Scales
3
Up to 500 lb
0.012 lb9
Weight kit
Pipettes
3
(0.5 to 100) μL
(100 to 10 000) μL
(0.0064 + 0.025 vol) μL
(1.4 + 0.0002 vol) μL
Laboratory balances
Pressure Gages
3
(10 to 10 000) psig
(-15 to 0.001) psig
(0.001 to 300) psig
(300 to 10 000) psig
0.035 %
0.042 %
0.042 %
0.035 %
Dead weight tester
Pressure monitor | ||
| 21 | - | Test blocksShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 21 of 24
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Rockwell Hardness
Testers
3
HRC:
High
Medium
Low
HRBW:
High
Medium
Low
HR15N:
High
Medium
Low
HR30N:
High
Medium
Low
HR45N:
High
Medium
Low
HR15T:
High
Medium
Low
HR30T:
High
Medium
Low
1.3 HRC
1.2 HRC
1.2 HRC
1.5 HRBW
1.6 HRBW
2.3 HRBW
1.2 HR15N
1.2 HR15N
1 HR15N
1.2 HR30N
1.3 HR30N
1.5 HR30N
1.4 HR45N
1.7 HR45N
1.7 HR45N
1.1 HR15T
1.1 HR15T
1.3 HR15T
1.1 HR30T
1.1 HR30T
1.4 HR30T
Test blocks
Brinell Hardness
Testers
3
(100 to 240) HBW
(240 to 600) HBW
Above 600 HBW
1 HBW
1.9 HBW
5.1 HBW
Test blocks
Vickers Hardness
Testers3
(170 to 700) HV
15 HV
Test blocks
Knoop Hardness
Testers
3
(170 to 200) HK
(200 to 400) HK
(400 to 700) HK
1 HK
2.4 HK
5.5 HK
Test blocks | See scope document |
| 22 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 22 of 24
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Torque Transducers
Torque Watches
Up to 10 ozfꞏin
(10 to 50) ozfꞏin
50 ozfꞏin to 10 lbfꞏin
(10 to 50) lbfꞏin
(50 to 100) lbfꞏin
(100 to 250) lbfꞏin
(250 to 600) lbfꞏin
0.023 ozfꞏin
0.05 ozfꞏin
0.005 lbfꞏin
0.013 lbfꞏin
0.053 lbfꞏin
0.08 lbfꞏin
0.16 lbfꞏin
Dead weights,
torque arms &
wheels
Torque Wrenches
3
Up to 26 ozfꞏin
26 ozfꞏin to 50 lbfꞏin
(50 to 500) lbfꞏin
500 lbfꞏin to 150 lbf∙ft
(150 to 250) lbf∙ft
(250 to 600) lbf∙ft
(600 to 1000) lbf∙ft
0.23 ozfꞏin
0.23 lbfꞏin
0.94 lbfꞏin
0.38 lbf∙ft
0.40 lbf∙ft
3.5 lbf∙ft
3.6 lbf∙ft
Torque transducer
system
VI. Thermodynamics
Parameter/Equipment
Range
CMC
2, 7 (±)
Comments
Temperature – Measure
(-180 to 0) °C
(0 to 100) °C
(100 to 200) °C
(200 to 400) °C
(400 to 600) °C
0.000 03 °C/°C + 0.026 °C
0.000 065 °C/°C + 0.025 °C
0.000 14 °C/°C + 0.018 °C
0.000 11 °C/°C + 0.025 °C
0.000 051 °C/°C + 0.047 °C
Fluke 1524
thermometer,
Fluke 5615/6,
Fluke 5609
Temperature –
Measuring Equipment
(-30 to 140) °C
(-30 to 670) °C
0.000 072 °C/°C + 0.022 °C
0.000 066 °C/°C + 0.021 °C
Fluke 1523A,
Fluke 5615/6,
Fluke 5609, Fluke
9011 Dry well
Humidity
3 – Measure
(15 to 90) % RH
(90 to 95) % RH
1.4 % RH
2.2 % RH
Vaisala HMI41,
HMP46 humidity
indicator & probe | to 1000 lbf∙ft |
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 23 of 24
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Humidity
3 – Measuring
Equipment
(15 to 90) % RH
(90 to 95) % RH
(10 to 85) °C
1.5 % RH
1.7 % R H
0.032 °C
Vaisala HMI41,
HMP46 humidity
indicator & probe,
Test Equity 123H
temperature/humidity
chamber
Fluke 1523A, Fluke
5615/6
VII. Time & Frequency
Parameter/Equipment
Range
CMC
2, 7 (±)
Comments
Frequency – Generate
3
DC to 600 MHz
600 MHz to 40 GHz
0.061 μHz/Hz +0 .041 Hz
0.77 μHz/Hz + 1.3 Hz
Fluke 5522A multi
product calibrator w/
Fluke PM6681R
Agilent E8257D
signal generator w/
Agilent 53152A
Frequency – Measure
3
0.11 Hz to 1.3 GHz
10 Hz to 46 GHz
DC to 12.4 GHz
0.000 44 µHz/Hz
13 µHz/Hz
4.7 µHz/Hz
Fluke PM6681R
Agilent 53152A
Agilent 53131A
frequency counters
Frequency –
Dissemination
10 MHz
5.8 x 10
-10 Hz
Fluke PM6681R
Timers & Stopwatches
3
(0 to 19.99) sec/day
0.061 sec/day
Timometer 4500
____________________________________________
1
This laboratory offers commercial dimensional testing, calibration and field calibration service. | ||
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5428.01) 12/31/2025 Page 24 of 24
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standa rds or nearly ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertain ty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3
Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC’s are expressed as either a speci fic value that covers the full range or as a
percentage or fraction of the reading plus a fixed floor specification.
5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
W is the applied weight in milligrams. In the statement of CMC, the value is defined as the percentage of
reading, unless otherwise noted. In the statement of CMC, vol is defined as the volume of the reading.
6 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
7 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration.
9 In the statement of CMC the resolution of the instrument is not taken into account. Addition of 0.6 times
the resolution will be added to the uncertainty for the individual unit under test.
10 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 25 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- J&W InstrumentsNew Brighton, MN · ~11 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - MinneapolisBloomington, MN · ~37 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- United StandardsBloomington, MN · ~37 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - ROCKFORDRockford, IL · ~470 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Quality Calibration ServiceNew Berlin, WI · ~476 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.