Samoto & Associates,
Namamugi 1-1-22-102, Tsurumi-Ku, Yokohama, Kanagawa, 230-0052, Japan, Yokohama, Kanagawa, Japan
Visit website- Accredited standards
- 24
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 24 standard numbers and the 18 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series16
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-7
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
IEC 61000-4-10
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
IEC 61000-4-14
IEC 61000-4-15
ISO 7637 series3
ISO 7637-1Road vehicles - Electrical disturbances from conduction and coupling - Part 1: Vocabulary and general considerations
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 16-1-2
ETSI TS 102 321
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 17069Accessible design - Consideration and assistive products for accessible meeting
CISPR 16-1-1; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6; EN 61000-4-11; EN 61000-4-5; IEC 61000-4-2; IEC 61000-3-2; IEC 61000-3-3; IEC 61000-4-6; IEC 61000-4-7; IEC 61000-4-8; IEC 61000- 4-9; IEC 61000-4-10; IEC 61000-4-11; IEC 61000- 4-12; IEC 61000-4-13; IEC 61000-4-14; IEC 61000-4-15; ANSI 62.41:1991; ANSI C63.16; ANSI C62- 41; UL 864; UL 1449; ISO 7637-2; ISO 17069; ITU Rec K.17; ITU Rec K.20; ITU Rec K.21; SBC -TP-76200; GR1089CORE; SAE J1113- 13
CISPR 16-1-2; ANSI C63.4; CISPR 16-1-4: 2010-04; IEC 61000-4-6 (2008); IEC 61000-4-6; CISPR 16-1-2 (2003); CISPR 16-1-2; IEC 61000-4-6; IEC 61000-4-2 (2001, 2008, 2025); ISO 10605 (2008, 2023); SAE J 1113-13
ANSI C63.4; ANSI C63.4a-2017; CISPR 16-1-4: (2010, 2017, 2023); ETSI TS 102 321; ANSI C63.25.1: 5.1(a); IEC 61000-4-3; IEEE1309
IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-11
ISO 7637-1; ISO 7637-2 (2004, 2011); ISO 7637-3; JASO D-001-94; IEC 61000-4-8; IEC 61000-4-9; CISPR16-1-4
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
18 lines
ISO/IEC 17025
Active2067.01
The scope document we hold says it is valid until 2027-06-30.
Location
Namamugi 1-1-22-102, Tsurumi-Ku, Yokohama, Kanagawa, 230-0052, Japan, Yokohama, Kanagawa, JP
35.45034, 139.63438
Open in MapsLabs with overlapping accredited scope in Japan
- OHTAMA CALIBRATION SERVICE Co.,Kanagawa · ~24 kmA2LAShares 2 accredited test methodsANSI C63.4CISPR 16-1-2
- TOYO Corporation Calibration LaboratoryTokyo 135-0042 · ~28 kmA2LAShares 2 accredited test methodsANSI C63.4CISPR 16-1-2
- UL Japan, Inc. - Kashima EMCChiba-ken, 289-0341 · ~44 kmA2LAShares 2 accredited test methodsANSI C63.4CISPR 16-1-2
- OKI ENGINEERING CO.,Honjo-shi, Saitama-ken · ~97 kmA2LAShares 2 accredited test methodsANSI C63.4CISPR 16-1-2
- LAB SupportAzumino-shi, Nagano-ken · ~182 kmA2LAShares 2 accredited test methodsANSI C63.4CISPR 16-1-2
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.