CalSource
1005 West Fayette Street, Suite 4D, 13204, Syracuse, NY, United States
Visit website- Scope lines
- 26
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 26 scope lines.
A2LA certificate 2133.01 · 26 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 17025:2017 | - | to 180 ° |
| 2 | ASME | Steel | See scope document |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 3 of 25
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Surface Plates3 –
Flatness Overall
Flatness Local Area
(Repeat Reading)
Up to 70 in Diagonal
(80 to 161) in Diagonal
Up to 0.001 in
160 µin
280 µin
55 µin
Planekator
Datum gauge
(Repeat-o-meterTM)
II. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
DC Voltage3
– Measure
Voltage Ratio
Up to 200 mV
200 mV to 2V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
(1 to 10) kV
Up to 200 mV
200 mV to 20 V
4.2 µV/V + 0.5 µV
2.8 µV/V + 0.7 µV
3.0 µV/V + 1 µV
4.2 µV/V + 42 µV
4.5 µV/V + 0.6 mV
0.26 %
5.1 µV/V
8.1 µV/V
Fluke 8588A
HP 3458A w/ divider
Fluke 8588A
DC Voltage3 – Generate
Fixed Point
Up to 220 mV
220 mV to 2.2 V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
10 V
10 µV/V + 0.4 µV
5.2 µV/V + 0.7 µV
4.1 µV/V + 3.0 µV
3.6 µV/V + 4.0 µV
6.1 µV/V + 50 µV
8.1 µV/V + 500 µV
2.0 parts in 106 V
Fluke 5730A/03
Fluke 7000 & 7000N
DC Current3 – Measure
Up to 20 µA
20 µA to 200 µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2.0 A
(2 to 20) A
(20 to 30) A
25 µA/A + 6.9 nA
3.0 µA/A + 6.9 nA
6.4 µA/A + 8.7 nA
8.5 µA/A + 60 nA
33 µA/A + 1.3 µA
110 µA/A + 100 µA
140 µA/A + 1.8 mA
400 µA/A + 8.1 mA
Fluke 8588A | to 70 in |
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 4 of 25
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
DC Current3 – Generate
(Toroidal & Other-type
clamps)
Up to 220 µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 10) A
(10 to 20) A
(20 to 1000) A
41 µA/A + 6 nA
36 µA/A + 7 nA
36 µA/A + 40 nA
44 µA/A + 1.4 µA
130 µA/A + 12 µA
380 µA/A + 480 µA
21 mA
0.65 %
Fluke 5730A/03
w/ 5725A
Fluke 5520
Fluke 5520 w/ coil
Resistance3 – Measure
Up to 2 Ω
(2 to 20) Ω
(20 to 200) Ω
200 Ω to 2 kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
(1 to 10) kΩ
18 µΩ/Ω + 4 µΩ
10 µΩ/Ω + 25 µΩ
9.0 µΩ/Ω + 220 µΩ
9.0 µΩ/Ω + 2.0 mΩ
9.0 µΩ/Ω + 20 mΩ
9.0 µΩ/Ω + 230 mΩ
10 µΩ/Ω + 3.5 Ω
15 µΩ/Ω + 250 Ω
120 µΩ/Ω + 11 kΩ
1.7 mΩ/Ω + 1.5 MΩ
1.7 µΩ/Ω
Fluke 8588A
Thomas 1 Ω & Fluke
8508A/01
Resistance3 – Generate
Up to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330 Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
330 MΩ to 1.1 GΩ
28 µΩ/Ω + 0.001 Ω
21 µΩ/Ω + 0.0015 Ω
21 µΩ/Ω + 0.0014 Ω
21 µΩ/Ω + 0.002 Ω
21 µΩ/Ω + 0.002 Ω
21 µΩ/Ω + 0.02 Ω
21 µΩ/Ω + 0.02 Ω
22 µΩ/Ω + 0.2 Ω
21 µΩ/Ω + 0.2 Ω
24 µΩ/Ω + 2 Ω
24 µΩ/Ω + 2 Ω
60 µΩ/Ω + 30 Ω
90 µΩ/Ω + 50 Ω
0.017 % + 2.5 kΩ
0.036 %
0.45 %
1.1 %
Fluke 5520A | to 220 µA |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 5 of 25
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Resistance3 – Generate
Fixed Points
1 Ω
1.9 Ω
10 Ω
19 Ω
100 Ω
190 Ω
1 kΩ
1.9 kΩ
10 kΩ
19 kΩ
100 kΩ
190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
1 Ω
96 µΩ/Ω
96 µΩ/Ω
24 µΩ/Ω
24 µΩ/Ω
11 µΩ/Ω
11 µΩ/Ω
7.3 µΩ/Ω
7.4 µΩ/Ω
7.3 µΩ/Ω
7.4 µΩ/Ω
9.2 µΩ/Ω
9.2 µΩ/Ω
14 µΩ/Ω
19 µΩ/Ω
41 µΩ/Ω
49 µΩ/Ω
0.011 %
0.7 µΩ/Ω
Fluke 5730A/03
Thomas 1 Ω | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 6 of 25
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
Capacitance – Measure
100 pF to 100 µF
100 µF to 500 µF
100 µF to 1000 µF
1000 µF to 3300 µF
100 pF to 100 nF
100 nF to 100 µF
100 µF to 1000 µF
1 kHz Only
1 kHz Only
1 kHz Only
1 kHz Only
500 Hz to 10 kHz
12 Hz to 10 kHz
50 Hz to 2 kHz
0.07 %
0.25 %
0.48 %
1.50 %
0.20 %
0.20 %
1.90 %
Genrad 1689
Phase3 – Generate
(Dual ACV Outputs)
3.3V, PF 0 to 1 (0 to 90)°
3.3V, PF 1 (0 to 90)°
(10 to 65) Hz
(65 to 500) Hz
500 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.07°
0.17°
0.34°
1.7°
3.4°
6.7°
Fluke 5520A
Inductance – Generate
100 μH
1 mH
10 mH
100 mH
1 H
10 H
100 Hz to 10 kHz
100 Hz to 1 kHz
0.26 μH
0.0011 mH
0.011 mH
0.11 mH
0.0011 H
0.011 H
General radio 1482-x
standard inductors | ||
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 7 of 25
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Current3 – Generate
Up to 220 μA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(11 to 20.5) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(20 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(40 to 1000) Hz
(1 to 5) kHz
(5 to 10) kHz
(10 to 65) Hz
(65 to 300) Hz
300 Hz to 1 kHz
(1 to 3) kHz
(3 to 6) kHz
(6 to 10) kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.029 % + 16 nA
0.019 % + 10 nA
0.014 % + 8 nA
0.031 % + 12 nA
0.12 % + 65 nA
0.027 % + 40 nA
0.020 % + 35 nA
0.010 % + 35 nA
0.023 % + 110 nA
0.13 % + 650 nA
0.028 % + 400 nA
0.020 % + 350 nA
0.015 % + 350 nA
0.024 % + 550 nA
0.12 % + 5 mA
0.028 % + 4.0 μA
0.021 % + 3.5 μA
0.017 % + 2.5 μA
0.025 % + 3.5 μA
0.12 % + 10 μA
0.028 % + 35 μA
0.051 % + 80 μA
0.74 % + 160 μA
0.052 % + 170 μA
0.11 % + 380 μA
0.38 % + 750 μA
0.019 % + 9.4 mA
0.03 % + 9.4 mA
0.085 % + 9.4 mA
0.25 % + 31 mA
0.82 % + 62 mA
2.4 % + 94 mA
0.33 % + 0.003A
0.91 % + 0.003A
0.33 % + 0.025A
0.92 % + 0.027A
0.35 % + 0.09A
0.93 % + 0.1A
Fluke 5730A/03
Fluke 5730A/03 w/
5725A
Fluke 52120A
LCOMP off
Fluke 5522A & coil | to 1025 A |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 8 of 25
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Current3 – Measure
Up to 20 μA
(20 to 200) μA
200 μA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
(20 to 30) A
1 Hz to 30 kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 10 kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.045 % + 2.5nA
0.033 % + 5 nA
0.050 % + 5 nA
0.084 % + 5 nA
0.48 % + 10 nA
0.027 % + 50 nA
0.053 % + 50 nA
0.083 % + 50 nA
0.42 % + 100 nA
0.027 % + 500 nA
0.061 % + 500 nA
0.078 % + 500 nA
0.42 % + 1 µA
0.027 % + 5 µA
0.052 % + 5 µA
0.091 % + 5 µA
0.027 % + 100 µA
0.054 % + 100 µA
0.074 % + 100 µA
0.083 % + 500 µA
0.081 % + 12 mA
0.085 % + 12 mA
Fluke 8588A | ||
| 9 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 9 of 25
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage3 – Generate
Up to 2.2 mV
(2.2 to 22) mV
(22 to 220) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.052 % + 4 µV
0.05 % + 4 µV
0.049 % + 4 µV
0.10 % + 4 µV
0.15 % + 5 µV
0.24 % + 10 µV
0.40 % + 20 µV
0.53 % + 20 µV
0.025 % + 4 µV
0.013 % + 4 µV
0.012 % + 4 µV
0.026 % + 4 µV
0.06 % + 5 µV
0.12 % + 10 µV
0.16 % + 20 µV
0.29 % + 20 µV
0.024 % + 12 µV
93 µV/V + 7 µV
61 µV/V + 7 µV
0.02 % + 7 µV
0.03 % + 17 µV
0.07 % + 20 µV
0.15 % + 25 µV
0.28 % + 45 µV
Fluke 5730A/03 | to 0.0022 V |
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 10 of 25
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage3 – Generate
(cont)
(0.22 to 2.2) V
(2.2 to 22) V
(22 to 220) V
(220 to 1100) V
(220 to 750) V
(220 to 1100) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) Hz
50 Hz to 1 kHz
(30 to 50) kHz
(50 to 100) kHz
(1 to 20) kHz
(20 to 30) kHz
0.024 % + 40 µV
93 μV/V + 15 µV
44 μV/V + 8 µV
70 μV/V + 10 µV
91 μV/V + 30 µV
0.04 % + 80 µV
0.10 % + 200 µV
0.18 % + 300 µV
0.024 % + 400 µV
92 µV/V + 150 µV
44 µV/V + 50 µV
70 µV/V + 100 µV
90 µV/V + 200 µV
0.027 % + 600 µV
0.11 % + 2 mV
0.16 % + 3.2 mV
0.024 % + 4 mV
93 µV/V + 1.5 mV
54 µV/V + 0.6 mV
83 µV/V + 1 mV
0.016 % + 2.5 mV
0.091 % + 16 mV
0.44 % + 40 mV
0.81 % + 80 mV
0.03 % + 16 mV
0.007 % + 3.5 mV
0.061 % + 11 mV
0.23 % + 45 mV
0.018 % + 6 mV
0.066 % + 11 mV
Fluke 5730A/03
Fluke 5730A, volt-
hertz limitation over
100 kHz. Max output is
2.2 x 10
7 V-Hz.
Max 250 V for (15 to
50) Hz
Fluke 5730A w/ 5725A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 11 of 25
Parameter/Range
Frequency
CMC2, 5, 6
(±)
Comments
AC Voltage – Measure
600 µV to 2.2 mV
Flatness –
500 kHz to 30 MHz
(Relative to 1 kHz)
600 µV to 2.2 mV
(2.2 to 7) mV
Flatness –
500 kHz to 30 MHz
(Relative to 1 kHz)
(2.2 to 7) mV
(7 to 22) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(500 to 1000) kHz
500 kHz to 1.2 MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1.2 MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
0.24 % + 1.3 µV
0.13 % + 1.3 µV
0.12 % + 1.3 µV
0.14 % + 2.0 µV
0.19 % + 2.5 µV
0.36 % + 4.0 µV
0.61 % + 8.0 µV
0.71 % + 8.0 µV
0.094 % + 1.0 µV
0.12 % + 1.0 µV
0.19 % + 1.0 µV
0.33 % + 1.0 µV
0.83 % + 1.0 µV
1.10 % + 1.0 µV
0.099 % + 1.3 µV
0.058 % + 1.3 µV
0.046 % + 1.3 µV
0.078 % + 2.0 µV
0.12 % + 2.5 µV
0.22 % + 4.0 µV
0.28 % + 8.0 µV
0.052 % + 1.0 µV
0.054 % + 1.0 µV
0.095 % + 1.0 µV
0.17 % + 1.0 µV
0.35 % + 1.0 µV
0.51 % + 1.0 µV
0.031 % + 1.3 µV
0.023 % + 1.3 µV
0.017 % + 1.3 µV
0.028 % + 2.0 µV
0.039 % + 2.5 µV
0.086 % + 4.0 µV
0.12 % + 8.0 µV
Fluke 5790B/05 | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 12 of 25
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Voltage – Measure
(cont)
(22 to 70) mV
(70 to 220) mV
(220 to 700) mV
700 mV to 2.2 V
Flatness –
500 kHz to 30 MHz
(Relative to 1 kHz)
7 mV to 7 V
(2.2 to 7) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1.2 MHz
(1.2 to 2) MHz
(2 to 10) MHz
(10 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
0.027 % + 1.5 µV
0.017 % + 1.5 µV
91 µV/V + 1.5 µV
0.015 % + 2 µV
0.03 % + 2.5 µV
0.05 % + 4 µV
0.073 % + 8 µV
0.018 % + 1.5 µV
77 µV/V + 1.5 µV
40 µV/V + 1.5 µV
67 µV/V + 2 µV
0.015 % + 2.5 µV
0.023 % + 4 µV
0.037 % + 8 µV
0.018 % + 1.5 µV
66 µV/V + 1.5 µV
34 µV/V + 1.5 µV
48 µV/V + 2 µV
75 µV/V + 2.5 µV
0.017 % + 4 µV
0.028 % + 8 µV
0.017 %
54 µV/V
24 µV/V
43 µV/V
65 µV/V
0.016 %
0.025 %
0.063 %
0.067 %
0.092 %
0.15 %
0.31 %
0.48 %
0.016 %
59 µV/V
24 µV/V
46 µV/V
74 µV/V
0.02 %
0.037 %
Fluke 5790B/05 | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 13 of 25
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Voltage – Measure
(cont)
Flatness –
10 Hz to 500 kHz
(Relative to 1 kHz)
(7 to 22) V
(22 to 70) V
(70 to 220) V
(10 to 30) Hz
2.2 mV to 7 V
(30 to 120) kHz
2.2 mV to 7 V
(120 to 500) kHz
(2.2 to 22) mV
(120 to 500) kHz
(22 to 70) mV
(120 to 500) kHz
(70 to 220) mV
(120 to 500) kHz
(220 to 700) mV
(120 to 500) kHz
700 mV to 7 V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
0.10 %
0.06 %
0.09 %
0.063 %
0.056 %
0.046 %
0.053 %
0.016 %
54 µV/V
23 µV/V
41 µV/V
71 µV/V
0.018 %
0.037 %
0.016 %
59 µV/V
27 µV/V
48 µV/V
81 µV/V
0.02 %
0.041 %
0.11 %
0.017 %
58 µV/V
30 µV/V
58 µV/V
88 µV/V
0.024 %
0.047 %
Fluke 5790B/05 | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 14 of 25
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Voltage – Measure
(cont)
(220 to 700) V
(700 to 1000) V
(1 to 10) kV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(45 to 65) Hz
0.016 %
86 µV/V
36 µV/V
0.012 %
0.042 %
0.017 %
85 µV/V
42 µV/V
0.011 %
0.041 %
0.64 %
Fluke 5790B/05
HP 3458A w/ divider
Distortion – Measure
20 Hz to 20 kHz
(20 to 100) kHz
1.3 dB
2.4 dB
HP 8903B
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Capacitance3 – Generate
(0.19 to 3.3) nF
(3.3 to 11) nF
(11 to 110) nF
(110 to 330) nF
(0.33 to 1.1) μF
(1.1 to 3.3) μF
(3.3 to 11) μF
(11 to 33) μF
(33 to 110) μF
(110 to 330) μF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
0.37 % + 0.01 nF
0.28 % + 0.01 nF
0.23 % + 0.1 nF
0.23 % + 0.3 nF
0.23 % + 1 nF
0.23 % + 3 nF
0.24 % + 10 nF
0.32 % + 30 nF
0.34 % + 100 nF
0.35 % + 300 nF
0.35 % + 1 μF
0.32 % + 3 μF
0.32 % + 10 μF
0.52 % + 30 μF
0.81 % + 100 μF
Fluke 5520A | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 15 of 25
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples &
Thermocouple Indicators 3 –
Type B
Type C
Type E
Type J
Type K
Type L
Type N
Type R
(600 to 800) °C
(800 to 1000) °C
(1000 to 1550) °C
(1550 to 1820) °C
(0 to 150) °C
(150 to 650) °C
(650 to 1000) °C
(1000 to 1800) °C
(1800 to 2316) °C
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 °C to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to 800) °C
(800 to 900) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 400) °C
(400 to 1000) °C
(1000 to 1767) °C
0.34 °C
0.27 °C
0.24 °C
0.26 °C
0.24 °C
0.21 °C
0.25 °C
0.39 °C
0.65 °C
0.39 °C
0.13 °C
0.12 °C
0.13 °C
0.17 °C
0.22 °C
0.13 °C
0.12 °C
0.14 °C
0.19 °C
0.26 °C
0.15 °C
0.13 °C
0.21 °C
0.32 °C
0.29 °C
0.21 °C
0.14 °C
0.32 °C
0.18 °C
0.15 °C
0.15 °C
0.22 °C
0.45 °C
0.28 °C
0.26 °C
0.32 °C
Fluke 5520A | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 16 of 25
Parameter/Equipment
Range
CMC2, 5, 6
(±)
Comments
Electrical Simulation of
Thermocouples &
Thermocouple
Indicators –
(cont)
Type S
Type T
Type U
(0 to 250) °C
(250 to 1000) °C
(1000 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
(-200 to 0) °C
(0 to 400) °C
0.37 °C
0.28 °C
0.30 °C
0.37 °C
0.50 °C
0.20 °C
0.14 °C
0.12 °C
0.44 °C
0.22 °C
Fluke 5520A
Electrical Simulation of
RTD3 –
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to 0) °C
(0 to 100) °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(-200 to -190) °C
(-190 to -80) °C
(-80 to 0) °C
(0 to 100) °C
(100 to 260) °C
(260 to 300) °C
(300 to 400) °C
(400 to 600) °C
(600 to 630) °C
0.041 °C
0.056 °C
0.072 °C
0.095 °C
0.097 °C
0.041 °C
0.057 °C
0.073 °C
0.081 °C
0.097 °C
0.21 °C
0.033 °C
0.041 °C
0.049 °C
0.056 °C
0.064 °C
0.073 °C
0.081 °C
0.19 °C
Fluke 5520A
AC Power, Low
Frequency3 – Generate
3.3 mA to 21 A,
(45 to 65) Hz
(33 to 330) mV
(0.33 to 1020) V
0.12 %
0.18 %
Fluke 5520A | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 17 of 25
Parameter/Equipment
Range
CMC2, 5, 6
(±)
Comments
DC Power3 –
Generate
(0.33 to 30) mA
(0.33 to 3) A
(3 to 21) A
33 mV to 1020 V
33 mV to 1020 V
33 mV to 1020 V
0.019 %
0.019 %
0.071 %
Fluke 5520A
Phase - Measure
(0 to 360°)
5 Hz to 2 kHz
>2 kHz to 5 kHz
>5 kHz to 10kHz
>10 kHz to 50 kHz
>50 kHz to 1 MHz
0.033°
0.04°
0.048°
0.057°
1.0°
Clarke-Hess 6000A
Oscilloscope3 –
Squarewave
Signal
(50 Ω at 1 kHz)
(1 MΩ at 1 kHz)
Leveled Sine
Wave
Amplitude
Flatness
(Rel. to 50 kHz)
Time Marker
(50 Ω Source &
Period)
Rise Time
1 mV to 6.6 V
1 mV to 130 V
50 kHz reference
50 kHz to 500 MHz
(500 to 3200) MHz
5 s to 50 ms
20 ms to 2 ns
(125 to 175)ps
0.21 % + 40 μV
0.099 % + 40 μV
2.5 %
5 %
6.1 %
0.6 µs/s
0.33 µs/s
20 ps
Fluke 5520A/SC600
Fluke 9500B/9530
Fluke 9500B/9530
Fluke 9500B/9530 | ||
| 18 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 18 of 25
III. Electrical – RF/Microwave
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
RF Power Reference
1 mW, 50 MHz
0.03 mW
HP 478A w/
432A & 3458A
RF Power Sensor
Calibration Factors
100 kHz to 4.6 GHz
(4.6 to 18) GHz
(18 to 26.5) GHz
1.0 %
1.7 %
4.7 %
Tegam F1130B,
Tegam 1830A
HP 8485A,
HP E4418B
HP 11667B
S-Parameter – S11/S22
Magnitude (linear)
100 kHz to 10 MHz
10 MHz to 3 GHz
(3 to 9) GHz
(9 to 18) GHz
0.5 % of rdg + 0.01 rho
0.7 % of rdg + 0.012 rho
1.6 % of rdg + 0.022 rho
3.9 % of rdg + 0.042 rho
Keysight
E5063A
S-Parameter – S11/S22
Phase (Degrees)9
100 kHz to 10 MHz, rho >0.025
100 kHz to 10 MHz, rho >0.1
10 MHz to 3 GHz, rho>0.05
10 MHz to 3 GHz, rho>0.1
(3 to 9) GHz, rho>0.1
(3 to 9) GHz, rho>0.2
(9 to 18) GHz, rho >0.2
12°
3.9°
9.5°
5.1°
12°
6°
17°
Keysight
E5063A
Attenuation –
Source, 1dB Steps
(1 to 3) dB, <1 GHz
(1 to 3) dB, (1 to 11) GHz
(1 to 3) dB, (11 to 18) GHz
(4 to 7) dB, <1 GHz
(4 to 7) dB, (1 to 11) GHz
(4 to 7) dB, (11 to 18) GHz
(8 to 11) dB, <1 GHz
(8 to 11) dB, (1 to 11) GHz
(8 to 11) dB, (11 to 18) GHz
0.19 dB
0.20 dB
0.19 dB
0.17 dB
0.15 dB
0.24 dB
0.26 dB
0.27 dB
0.58 dB
HP8494B
Attenuation – Source,
10dB Steps
(10 to 30) dB, <1 GHz
(10 to 30) dB, (1 to 11) GHz
(10 to 30) dB, (11 to 18) GHz
(40 to 70) dB, <1 GHz
(40 to 70) dB, (1 to 11) GHz
(40 to 70) dB, (11 to 18) GHz
(80 to 110) dB, < 1GHz
(80 to 110) dB, (1 to 11) GHz
(80 to 110) dB, (11 to 18) GHz
0.24 dB
0.64 dB
1.6 dB
0.61 dB
0.66 dB
2.3 dB
0.59 dB
0.77 dB
4.7 dB
HP8496B | ||
| 19 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 19 of 25
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
RF Power – Generate
100 kHz to 10 MHz
(+20 to -100) dBm
10 MHz to 26.5 GHz
(+20 to -100) dBm
1.1 dB
0.28 dB
HP 8663A
synthesizer
HP 83630B
synthesizer
RF Power – Measure
100 kHz to 10 MHz
(-20 to +20) dBm
10 MHz to 26 GHz
(-1 to +20) dBm
0.73 dB
0.21 dB
Power Meter &
Sensors
RF Tuned
Power/Attenuation –
Measure
(2.5 to 1300) MHz
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
(1.3 to 26.5) GHz
(0 to -10) dB
(-10 to -20) dB
(-20 to -30) dB
(-30 to -40) dB
(-40 to -50) dB
(-50 to -60) dB
(-60 to -70) dB
(-70 to -80) dB
(-80 to -90) dB
(-90 to -100) dB
(-100 to -110) dB
0.038 dB
0.044 dB
0.048 dB
0.052 dB
0.073 dB
0.082 dB
0.091 dB
0.096 dB
0.12 dB
0.12 dB
0.13 dB
0.035 dB
0.042 dB
0.046 dB
0.050 dB
0.072 dB
0.081 dB
0.090 dB
0.095 dB
0.12 dB
0.12 dB
0.13 dB
Agilent 8902A
receiver
Agilent 8902A
receiver w/ 11793A
converter | ||
| 20 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 20 of 25
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Amplitude Modulation –
Measure
Rate: 50 Hz to 10 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 10 kHz
Depth: (5 to 99) %
Rate: 50 Hz to 50 kHz
Depth: (5 to 99) %
Rate: 20 Hz to 100 kHz
Depth: (5 to 99) %
Rate: 50 Hz to 50 kHz
Depth: (5 to 99) %
Rate: 50 Hz to 50 kHz
Depth: (5 to 99) %
(0.15 to 10) MHz
(0.15 to 10) MHz
(0.01 to 1.3) GHz
(0.01 to 1.3) GHz
(1.3 to 26.5) GHz
(1.3 to 26.5) GHz
2.4 %
3.6 %
1.3 %
3.6 %
1.9 %
3.6 %
Agilent 8902A
Receiver
Agilent 8902A
Receiver w/ 11793A
Converter
Frequency Modulation –
Measure
Rate: 20 Hz to 10 kHz
Dev: ≤ 40 kHz peak
Rate: 50 Hz to 100 kHz
Dev: ≤ 400 kHz peak
Rate: 20 Hz to 200 kHz
Dev: ≤ 4.0 kHz peak
Rate: 50 Hz to 100 kHz
Dev: ≤ 400 kHz peak
Rate: 20 Hz to 200 kHz
Dev: ≤ 400 kHz peak
(0.15 to 10) MHz
(0.01 to 1.3) GHz
(0.01 to 1.3) GHz
(1.3 to 26.5) GHz
(1.3 to 26.5) GH
2.5 %
1.4 %
6.1 %
1.4 %
6.1 %
Agilent 8902A
Receiver
Agilent 8902A
Receiver w/ 11793A
Converter
Phase Modulation –
Measure
Rate: 200 Hz to 10 kHz
Rate: 200 Hz to 20 kHz
(0.15 to 10) MHz
(0.01 to 26.5) GHz
4.9 %
3.7 %
Agilent 8902A
Receiver | 0.01 to 26.5 GHz |
| 21 | - | waterShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 21 of 25
IV. Fluid Quantities
Parameter/Equipment
Range
CMC2, 5, 8 (±) Comments
Liquid Flow3 – Measure
(1 to 10) GPM water
0.25 %
Direct comparison
using micro motion
flow meter
V. Mechanical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Pressure – Measuring
Equipment & Measure3
–
Gage/Absolute
Pressure
Hydraulic3
Negative Gage
Pressure
Barometric
Low
(0.2 to 25) psi
(1.7 to 100) psi
(2 to 1000) psi
(1000 to 10 000) psig
(-14.5 to 0) psig
(10 to 16) psia
(0.01 to 2) in H2O
(2 to 10) in H2O
0.0020 % rdg
0.018 % rdg
29 x 10-5 psi
0.01 % + 0.0003 psia
0.0034 in H2O
0.0021 in H2O
Ruska piston gage
Ametek TQ-100
DWT
Ruska piston gage
DHI RPM4
Micro tector
Hook gage | See scope document |
| 22 | ison using Class 1 | - | See scope document |
| 23 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 23 of 25
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Torque – Measuring
Equipment
(2 to 20) ozf·in
(15 to 200) ozf·in
(4 to 50) lbf·in
(30 to 400) lbf·in
(80 to 1000) lbf·in
(20 to 250) lbf·ft
(100 to 1000) lbf·ft
0.064 ozf·in
0.59 ozf·in
0.15 lbf·in
1.2 lbf·in
3.0 lbf·in
0.73 lbf·ft
3.0 lbf·ft
Torque arm & weights
Torque Wrenches
(1 to 20) ozf·in
(20 to 200) ozf·in
(5 to 50) lbf·in
(30 to 400) lbf·in
(80 to 1000) lbf·in
(20 to 250) lbf·ft
(100 to 1000) lbf·ft
0.41 ozf·in
0.61 % rdg
0.81 % rdg
0.61 % rdg
0.62 % rdg
0.70 % rdg
0.69 % rdg
Torque arm & weights
CDI torque system
Force – Compression,
Measuring Equipment
Up to 5 lbf
(5 to 50) lbf
(50 to 2000) lbf
(400 to 20 000) lbf
0.05 %
0.02 %
0.44 lbf
38 lbf
Weights
Load Cells
Force – Tension,
Measuring Equipment
(100 to 2000) lbf
0.34 lbf
Load cells | ||
| 24 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 24 of 25
VI. Thermodynamics
Parameter/Equipment
Range
CMC2, 8 (±)
Comments
Relative Humidity -
Measure3
(10 to 95) % RH
2.0 % RH
Rotronic RH
transmitter, Fluke
Hydra data logger
Temperature Measure 3 –
(-197 to 100) °C
(100 to 420) °C
(-40 to 250) °F
0.016 °C
0.028 °C
0.05 °F
Hart 1594A, SPRT
Temperature Measuring
Equipment
(-40 to 150) °C
(150 to 350) °C
0.016 °C
0.026 °C
Hart 1594A, SPRT
w/Fluid bath
Hart 1594A, SPRT,
w/Dry Well
IR Thermometers
(-15 to 120) °C
(35 to 500) °C
1.2 °C
1.6 °C
Hart Scientific 4180
Hart Scientific 4181
Emissivity 0.95
λ = (8 to 14) µm
Welch Allyn Blackbody
(29 to 43) °C
0.072 °C
Master blackbody,
SPRT
VII. Time & Frequency
Parameter/Equipment
Range
CMC2, 5, 8 (±)
Comments
Frequency – Measuring
Equipment3
10 MHz
0.01 Hz to 225 MHz
200 Hz to 5 GHz
5 GHz to 26.5 GHz
1.7 pHz/ Hz
4.7 nHz/Hz
4.5 nHz/Hz
1.6 nHz/Hz
Microchip S650,
GPS
Agilent 53132A, GPS
HP 5352B, GPS
Frequency – Measure3
0.01 Hz to 225 MHz
200 MHz to 5 GHz
5 GHz to 26.5 GHz
4.7 nHz/Hz
4.5 nHz/Hz
1.6 nHz/Hz
Agilent 53132A, GPS
HP 5352B, GPS
Stopwatches & Timers3
(0 to 19.99) s/day
0.043 s/day
Timometer 4500 | ||
| 25 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2133.01) 08/26/2024 Page 25 of 25
_________________________________________________
1 This laboratory offers commercial calibration and field calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to
influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. re solution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable
on a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches,
R is the numerical value of the resolution of the device in microinches, D is the numerical value of the
nominal diameter of the device measured in inches.
5 In the statement of CMC, the value is defined as the percentage of reading.
6 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges
indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction
of the reading plus a fixed floor specification.
7 This scope meets A2LA’s P112 Flexible Scope Policy .
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory
is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed
measurement parameter.
9 Uncertainty is assumed to be 180 deg for all values outside the defined conditions. | ||
| 26 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Advanced Plastic and Material TestingIthaca, NY · ~65 kmA2LAShares 1 accredited materialSteel
- WTTIAllentown, PA · ~278 kmA2LAShares 1 accredited materialSteel
- ABSOLUTE CLARITY & CALIBRATIONSouthington, CT · ~313 kmA2LAShares 1 accredited materialSteel
- Westmoreland Mechanical Testing & ResearchYoungstown, PA · ~408 kmA2LAShares 1 accredited materialSteel
- Cleveland Specialty Inspection ServicesMentor, OH · ~452 kmA2LAShares 1 accredited materialSteel
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.