Silsoe Odours
Building 42, Wrest Park, Silsoe, MK45 4HP, Bedfordshire, United Kingdom
Visit website- Accredited standards
- 2
- UKAS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the UKAS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 2 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
EN 13725Some methods
Limits written next to it
BS EN 13725:2022 Point source sampling using: - Lung method - Dynamic dilution - Static Dilution - Direct Sampling B Ambient Air Process Emissions Collection of odour samples for delayed olfactometry Documented In-house Method LP08 based on BS EN 13725:2022 Point source sampling using: - Lung method
ISO 10780Stationary source emissions - Measurement of velocity and volume flowrate of gas streams in ducts
BS EN 13725:2022 by dynamic olfactometry A GASES Sampling with subsequent analysis at an ISO/IEC 17025; BS EN 13725:2022 Point source sampling using: - Lung method - Dynamic dilution - Static Dilution - Direct Sampling B Ambient Air Process Emissions Collection of odour samples for delayed olfactometry Documented In-house Method LP08 based on BS EN 13725:2022 Point source sampling using: - Lung method - Dynamic dilution - Static Dilution - Direct sampling - Wafting method B Surface Emissions Collection of odour samples for delayed olfactometry Documented In-house Method LP08 based on BS EN 13725:2022 Area source sampling with outward flow using: - Sheet method - Lindvall Hood method B Surface Emissions Collection of odour samples for delayed olfactometry Documented In-house Method LP08 based on BS EN 13725:2022; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025; IEC 17025
BSEN16911-1:2013 and the current version of Environment Agency MID 16911-1 Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO10780; IEC 17025; in-house procedure LP12
BSEN16911-1:2013 Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO10780 and BSEN16911-1:2013 Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1; IEC 17025; in-house Method LP08
Read from the scope as published by UKAS. Register refreshed 2026-11-20.
Scope as published by UKAS
5 lines
ISO/IEC 17025
Active0609
Accredited scope, certificate 0609
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | - |
| 2 | BS EN 13725:2022 by dynamic olfactometry A GASES Sampling with subsequent analysis at an ISO/IEC 17025; BS EN 13725:2022 Point source sampling using: - Lung method - Dynamic dilution - Static Dilution - Direct Sampling B Ambient Air Process Emissions Collection of odour samples for delayed olfactometry Documented In-house Method LP08 based on BS EN 13725:2022 Point source sampling using: - Lung method - Dynamic dilution - Static Dilution - Direct sampling - Wafting method B Surface Emissions Collection of odour samples for delayed olfactometry Documented In-house Method LP08 based on BS EN 13725:2022 Area source sampling with outward flow using: - Sheet method - Lindvall Hood method B Surface Emissions Collection of odour samples for delayed olfactometry Documented In-house Method LP08 based on BS EN 13725:2022; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025; IEC 17025 | Air | - |
| 3 | ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025; IEC 17025; in-house procedure LP12 | Air | - |
| 4 | BSEN16911-1:2013 and the current version of Environment Agency MID 16911-1 Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO10780; IEC 17025; in-house procedure LP12 | Air | - |
| 5 | BSEN16911-1:2013 Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO10780 and BSEN16911-1:2013 Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1; IEC 17025; in-house Method LP08 | Stack emissions to atmosphere | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United Kingdom
- NPL ManagementMiddlesex · ~65 kmUKASShares 2 accredited materialsAirStack emissions to atmosphere
- SOCOTEC UKBurton upon Trent · ~118 kmUKASShares 2 accredited materialsAirStack emissions to atmosphere
- Olfasense UKBristol · ~158 kmUKASShares 2 accredited materialsAirStack emissions to atmosphere
- Cura Terrae OH and Emissions TestingWest Yorkshire · ~217 kmUKASShares 2 accredited materialsAirStack emissions to atmosphere
- Anchem Laboratories LtdWest Glamorgan · ~240 kmUKASShares 2 accredited materialsAirStack emissions to atmosphere
Accreditation data refreshed from the UKAS register on .