Registers refreshed 2026-11-20.See refresh dates
United Kingdom

Silsoe Odours

Building 42, Wrest Park, Silsoe, MK45 4HP, Bedfordshire, United Kingdom

Visit website
UKAS 0609ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
2
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

Our reading of the UKAS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 2 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

EN 13725Some methods

Limits written next to it

BS EN 13725:2022 Point source sampling using: - Lung method - Dynamic dilution - Static Dilution - Direct Sampling B Ambient Air Process Emissions Collection of odour samples for delayed olfactometry Documented In-house Method LP08 based on BS EN 13725:2022 Point source sampling using: - Lung method

Some methods. Written next to it on line 2 of UKAS certificate 0609.

ISO 10780Stationary source emissions - Measurement of velocity and volume flowrate of gas streams in ducts

Read from the scope as published by UKAS. Register refreshed 2026-11-20.

Scope as published by UKAS

5 lines
UKAS

ISO/IEC 17025

Active

0609

View scope

Accredited scope, certificate 0609

LineMethodMatrixRange
1ISO/IEC 17025:2017--
2BS EN 13725:2022 by dynamic olfactometry A GASES Sampling with subsequent analysis at an ISO/IEC 17025; BS EN 13725:2022 Point source sampling using: - Lung method - Dynamic dilution - Static Dilution - Direct Sampling B Ambient Air Process Emissions Collection of odour samples for delayed olfactometry Documented In-house Method LP08 based on BS EN 13725:2022 Point source sampling using: - Lung method - Dynamic dilution - Static Dilution - Direct sampling - Wafting method B Surface Emissions Collection of odour samples for delayed olfactometry Documented In-house Method LP08 based on BS EN 13725:2022 Area source sampling with outward flow using: - Sheet method - Lindvall Hood method B Surface Emissions Collection of odour samples for delayed olfactometry Documented In-house Method LP08 based on BS EN 13725:2022; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025; IEC 17025Air-
3ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025; IEC 17025; in-house procedure LP12Air-
4BSEN16911-1:2013 and the current version of Environment Agency MID 16911-1 Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO10780; IEC 17025; in-house procedure LP12Air-
5BSEN16911-1:2013 Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO10780 and BSEN16911-1:2013 Procedure to meet requirements of PD CEN TR 17078:2017 Measurement Objective 1; IEC 17025; in-house Method LP08Stack emissions to atmosphere-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Building 42, Wrest Park, Silsoe, Bedfordshire, MK45 4HP, GB

52.00757, -0.40830

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.