Registers refreshed 2026-11-08.See refresh dates
United States

Marvel Aero International, Inc., DBA Christie Distribution & Service Center

41780 N Vision Way, Bldg. 3, 85086, Phoenix, AZ, United States

Visit website
A2LA 7456.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 7456.01 · 3 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 400 mA
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7456.01) 5/29/2025 Page 2 of 2 II. Thermodynamics Parameter/Equipment Range CMC2, 7 (±) Comments Temperature – Measure (18 to 28) °C 2.5 °C Fluke 287 with 80TK & 80PK-1 III. Time & Frequency Parameter/Equipment Range CMC2, 7 (±) Comments Time – Measure (60 to 300) s 1.1 s Thomas 9371W22 timer ____________________________________________ 1 This laboratory offers commercial calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 In the statement of CMC, the value is defined as the percentage of reading. 5 The uncertainties shown relate to voltages that lie within ± 10 % of the specified values. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as eit her a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
18 to 28 °C
3ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

41780 N Vision Way, Bldg. 3, Phoenix, AZ, 85086, US

33.44844, -112.07414

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.