Marvel Aero International, Inc., DBA Christie Distribution & Service Center
41780 N Vision Way, Bldg. 3, 85086, Phoenix, AZ, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 7456.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 400 mA |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7456.01) 5/29/2025 Page 2 of 2
II. Thermodynamics
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Temperature – Measure
(18 to 28) °C
2.5 °C
Fluke 287 with 80TK &
80PK-1
III. Time & Frequency
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Time – Measure
(60 to 300) s
1.1 s
Thomas 9371W22 timer
____________________________________________
1 This laboratory offers commercial calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 In the statement of CMC, the value is defined as the percentage of reading.
5 The uncertainties shown relate to voltages that lie within ± 10 % of the specified values.
6 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as eit her a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | 18 to 28 °C |
| 3 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Fluke Calibration, Phoenix - Primary Pressure and FlowPhoenix, AZ · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- National CalibrationScottsdale, AZ · ~15 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - PhoenixScottsdale, AZ · ~15 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Applied Technical Services, LLC.Tempe, AZ · ~15 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ATLAS MATERIAL TESTING TECHNOLOGY LLC ATLAS WEATHERING SERVICES GROUPPhoenix, AZ · ~51 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.