Tektronix, Inc. - Beaverton
13725 SW Karl Braun Drive, M/S 19-BMC, 97077, Beaverton, OR, United States
Visit website- Scope lines
- 11
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 11 scope lines.
A2LA certificate 2357.01 · 11 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.01) Revised 01/13/2026 Page 2 of 10
Parameter/Equipment
Range CMC 2, 4, 5 (±) Comments
DC Voltage – Measure3,
Fixed Points (cont)
0.6 V
1.9 V
2.3 V
5 V
6 V
19 V
23 V
50 V
60 V
190 V
22 μV
74 μV
73 μV
170 μV
570 μV
720 μV
970 μV
1.9 mV
2.3 mV
6.5 mV
Agilent / HP 3458A
Oscilloscope Probe DC
Gain – Measure
(0 to 100) mV
100 mV to 1 V
(1 to 10) V
4.8 mV/V + 0.23 µV
0.6 mV/V + 0.23 µV
0.3 mV/V + 0.39 µV
Keithley 2700 &
Keithley 2400
AC Voltage – Generate3,
Sinewave (Vrms)
500 Hz
320 mV to 3.2 V
(3.2 to 32) V
(32 to 320) V
(320 to 800) V
0.14 %
0.13 %
0.10 %
0.10 %
Wavetek 9100
AC Voltage – Generate3,
Squarewave (Vp-p)
1 kHz
1 mV to 5.0 V, 50 Ω
1 mV to 200 V, 1 MΩ
0.79 mV/V + 7.8 µV
0.79 mV/V + 7.8 µV
Wavetek 9500, Fluke
9500/B w/ 9530
Parameter/Range
Frequency CMC 2, 5 (±) Comments
AC Voltage – Measure3
(0 to 10) mV
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
100 kHz to 1 MHz
(1 to 4) MHz
(4 to 8) MHz
0.27 µV/V + 2.3 µV
0.18 µV/V + 0.85 µV
0.25 µV/V + 0.85 µV
0.78 µV/V + 0.85 µV
3.9 µV/V + 0.85 µV
31 µV/V + 3.9 µV
54 µV/V + 5.4 µV
0.16 mV/V + 6.2 µV
Keysight 3458A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.01) Revised 01/13/2026 Page 3 of 10
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Measure3
(cont)
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 4) MHz
(4 to 8) MHz
(8 to 10) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
0.13 µV/V + 3.1 µV
71 nV/V + 1.6 µV
0.11 µV/V + 1.6 µV
0.23 µV/V + 1.6 µV
0.62 µV/V + 1.6 µV
2.3 µV/V + 7.8 µV
7.8 µV/V + 7.8 µV
31 µV/V + 54 µV
31 µV/V + 62 µV
0.12 V/V + 78 µV
0.28 mV/V + 31 µV
98 µV/V + 16 µV
0.14 mV/V + 16 µV
0.25 mV/V + 16 µV
0.63 mV/V + 16 µV
2.9 mV/V + 78 µV
7.9 mV/V + 78 µV
31 mV/V + 0.54 mV
31 mV/V + 0.62 mV
0.12 V/V + 0.78 mV
0.28 mV/V + 0.31 mV
97 µV/V + 0.16 mV
0.13 mV/V + 0.16 mV
0.25 mV/V + 0.16 mV
0.63 mV/V + 0.16 mV
2.9 mV/V + 0.78 mV
7.9 mV/V + 0.78 mV
31 mV/V + 5.4 mV
31 mV/V + 6.2 mV
0.12 V/V + 7.8 mV
0.31 mV/V + 3.1 mV
0.17 mV/V + 1.6 mV
0.17 mV/V + 1.6 mV
0.28 mV/V + 1.6 mV
0.93 mV/V + 1.6 mV
3.5 mV/V + 7.8 mV
12 mV/V + 7.8 mV
Keysight 3458A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.01) Revised 01/13/2026 Page 4 of 10
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
AC Voltage – Measure3
(cont)
(100 to 700) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.42 mV/V + 31 mV
0.32 mV/V + 16 mV
0.47 mV/V + 16 mV
0.93 mV/V + 16 mV
2.3 mV/V + 16 mV
Keysight 3458A
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Resistance – Generate
3
Fixed Points
(40 to 400) Ω
400 Ω to 4 kΩ
(4 to 40) kΩ
(40 to 400) kΩ
400 kΩ to 4 MΩ
(4 to 40) MΩ
50 Ω
1 MΩ
0.076 %
0.055 %
0.056 %
0.11 %
0.15 %
0.32 %
0.018 Ω
420 Ω
Wavetek 9100
ESI DB877 | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.01) Revised 01/13/2026 Page 5 of 10
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Capacitance – Generate
3
(20 to 25) pF
(80 to 90) pF
0.28 pF
0.57 pF
Fixed capacitor
Oscilloscopes
3 –
DC Voltage – Generate
50 Ω Load
1 MΩ Load
Sinewave Flatness –
Generate, 50 Ω Load,
50 kHz to 10 MHz
Reference, V
(p-p)
1 Hz to 100 MHz
(100 to 550) MHz
550 MHz to 1.1 GHz
(> 1.1 to 2.5) GHz
(> 2.5 to 3.2) GHz
1.0 GHz
2.0 GHz
2.5 GHz
(> 3.2 to 8.0) GHz
(> 3.2 to 8.0) GHz
(> 8 to 12.5) GHz
(> 8 to 12.5) GHz
(> 12.5 to 16) GHz
(> 12.5 to 16) GHz
(> 16 to 18) GHz
(> 16 to 18) GHz
(> 18 to 20) GHz
(> 18 to 20) GHz
(> 20 to 23) GHz
(> 20 to 23) GHz
(> 23 to 25) GHz
(> 23 to 25) GHz
(0 to ± 0.2) V
1 mV to ± 5.0 V
1 mV to ± 200 V
4.4 mV to 5.6 V
4.4 mV to 5.6 V
4.4 mV to 3.4 V
4.4 mV to 3.4 V
4.4 mV to 2.2 V
Up to 800 mV
Up to 800 mV
Up to 800 mV
Up to 300 mV
> 300 mV
Up to 300 mV
> 300 mV
Up to 300 mV
> 300 mV
Up to 300 mV
> 300 mV
Up to 300 mV
> 300 mV
Up to 120 mV
> 120 mV
Up to 120 mV
> 120 mV
44 μV
0.19 mV/V + 19 µV
0.2 mV/V + 19 µV
0.22 dB
0.27 dB
0.35 dB
0.39 dB
0.48 dB
0.22 dB
0.27 dB
0.34 dB
0.30 dB
0.31 dB
0.37 dB
0.38 dB
0.45 dB
0.42 dB
0.52 dB
0.42 dB
0.56 dB
0.40 dB
0.55 dB
0.58 dB
0.57 dB
0.61 dB
50 Ohm termination
Wavetek 9500, Fluke
9500/B w/ 9530
Wavetek 9500, Fluke
9500/B w/ 9530
Synthesized signal
generator w/ power
meter and splitter | 20 to 25 pF |
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.01) Revised 01/13/2026 Page 6 of 10
Parameter/Equipment
Range CMC 2, 4, 5 (±)
Comments
Oscilloscopes
3 – (cont)
Sinewave Flatness –
Generate, 50 Ω Load,
50 kHz to 10 MHz
Reference, V
(p-p)
(> 25 to 33) GHz
(> 25 to 33) GHz
(> 33 to 50) GHz
(> 50 to 59) GHz
(> 59 to 67) GHz
AC Voltage – Generate,
50 Ω, Sinewave, V
(p-p)
1 Hz to 550 MHz
550 MHz to 2.5 GHz
(2.5 to 3.2) GHz
(3.2 to 6.0) GHz
Time Mark – Generate
Input Resistance –
Measure
DC Voltage – Measure
Up to 120 mV
> 120 mV
Up to 30 mV
Up to 30 mV
Up to 30 mV
4.4 mV to 5.6 V
4.4 mV to 3.4 V
4.4 mV to 2.2 V
4.4 mV to 2.2 V
80 ms
400 ms
50 Ω
75 Ω
1 MΩ
(0 to ± 5) V
(0 to ± 0.2) V
0.87 dB
0.84 dB
0.36 dB
0.37 dB
0.41 dB
3.3 %
6.3 %
11 %
14 %
0.021 µs/s
3.4 ns/s
0.044 Ω
0.12 Ω
0.27 Ω
0.014 % + 90 µV
33 µV
Synthesized signal
generator w/ power
meter and splitter
Fluke
9500/B w/ 9530
Synthesized signal
generator
Wavetek 9500, Fluke
9500/B w/ 9530, w/
Fluke 910
Fluke 9500 w/ 9530 in
DMM mode
Keithley 2000
Tektronix MSO series | to 67 GHz |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.01) Revised 01/13/2026 Page 7 of 10
Parameter/Equipment
Range CMC2, 5 (±)
Comments
Oscilloscopes
3 – (cont)
RMS Noise – Measure
Risetime –
Generate
Jitter
Timeout Trigger
Accuracy
20 MHz BW
175 MHz BW
(0.2 to 10) GHz BW
(15 to 19) ps
0.03 ns
0.05 ns
62.5 ps
0.08 ns
83.3 ps
0.1 ns
166.7 ps
200 ps
(0.3 to 2) ns
400 ps
500 ps
1000 ps
2 ns
5 ns
10 ns
(2 to 14) ns
18 ns to 100 µs
100 MHz
0.18 µV
2.2 µV
1.1 µV
5.3 ps
0.021 ps
0.016 ps
0.0041 ps
0.025 ns
0.0015 ps
0.033 ns
0.0015 ps
0.0016 ps
0.03 ps
0.0017 ps
0.0018 ps
0.0065 ps
0.000 019 ns
0.000 026 ns
0.031 ps
0.14 ps
0.014 ps
1.1 ns
Tektronix MSO series
067133800
Anritsu MG3694C
Fluke 9500/B w/ 9530 | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.01) Revised 01/13/2026 Page 8 of 10
II. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 5 (±)
Comments
Spectrum Analyzer –
Third Order Intermodulation
0 dBm
0 dBm
Phase Noise @ 1 GHz
Frequency Offset
0 dBc/Hz
0 dBc/Hz
0 dBc/Hz
RF Power – Generate
10 dBm
10 dBm
10 dBm
10 dBm
0 dBm
0 dBm
0 dBm
0 dBm
-15 dBm
-15 dBm
-15 dBm
-15 dBm
RF Display Average Noise
(DANL)
-30 dBm
2.745 GHz
4.2025 GHz
10 kHz
100 kHz
1 MHz
(9 to 50) kHz
50 kHz to 1 MHz
1 MHz to 2 GHz
(2 to 6) GHz
(9 to 50) kHz
50 kHz to 1 MHz
1 MHz to 2 GHz
(2 to 6) GHz
(9 to 50) kHz
50 kHz to 1 MHz
1 MHz to 2 GHz
(2 to 6) GHz
(9 to 50) kHz
50 kHz to 5 MHz
(5 to 400) MHz
(0.4 to 3) GHz
(3 to 4) GHz
(4 to 6) GHz
1.6 dB
1.6 dB
1.1 dB
1.0 dB
1.0 dB
0.40 dB
0.43 dB
0.39 dB
0.51 dB
0.37 dB
0.37 dB
0.35 dB
0.37 dB
0.39 dB
0.44 dB
0.37 dB
0.39 dB
2.9 dBm/Hz
1.6 dBm/Hz
0.46 dBm/Hz
0.61 dBm/Hz
0.56 dBm/Hz
0.48 dBm/Hz
Anritsu MG3692C
Anritsu MG3692C
Anritsu MG3692C
Maury 2510B6 N-type
50 ohm terminator | to 6 GHz |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.01) Revised 01/13/2026 Page 9 of 10
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
RF Flatness – Measure
3
100 mV
100 mV
100 mV
300 mV
300 mV
1 V
1 V
1 V
3 V
3 V
(10 to 550) MHz
550 MHz to 1.5 GHz
(1.5 to 3) GHz
10 MHz to 1.5 GHz
(1.5 to 3) GHz
(10 to 550) MHz
550 MHz to 1.5 GHz
(1.5 to 3 GHz)
10 MHz to 2 GHz
2.5 GHz
1.4 %
2.1 %
2.7 %
1.4 %
2.6 %
1.4 %
2.0 %
2.6 %
1.7 %
2.0 %
Rhode & Schwarz
NRVS and NRV-Z5
III. Time & Frequency
Parameter/Equipment
Range
CMC2, 7 (±)
Comments
Frequency & Period –
Measuring Equipment
12 kHz to 3.2 GHz
(3.2 to 40) GHz
1.3 parts in 10
9
1.4 parts in 10
6
Fluke 9500/B w/
9530, Fluke 910
Anritsu MG3694C,
Fluke 910
Frequency – Measure
0.001 Hz to 1 kHz
(1 to 1000) kHz
(1 to 225) MHz
0.12 mHz/Hz
0.3 nHz/Hz
0.12 nHz/Hz
Keysight 53131A,
Fluke 910
(Delta Time Accuracy)
Time Measurement
Up to 1 GHz
(1 to 2) GHz
(2 to 16) GHz
(14.28 to 43.47) GHz
2.8 ps
0.14 ps
0.0015 ps
0.12 ps
Anritsu MG3694C
Agilent E8257D
_________________________________________ | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2357.01) Revised 01/13/2026 Page 10 of 10
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC Uncertainty due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of the CMC, the given percentages are percent of reading.
5 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The type of instrument or material being calibra ted is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter. | ||
| 11 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- G.T. MICHELLI CO., LLC - BEAVERTONBeaverton, OR · under 1 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- JJ CalibrationsPortland, OR · ~11 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Global Calibration ServicesTukwila, WA · ~224 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ThermetricsSeattle, WA · ~238 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - SeattleRedmond, WA · ~248 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.