G.T. MICHELLI CO., LLC - BEAVERTON

7933 SW Nimbus #28, 97008, Beaverton, OR, United States

Visit website
A2LA 3601.12ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 3601.12 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3601.12) Revised 12/18/2025 Page 2 of 3 Parameter/Equipment Range CMC2, 5 (±) Comments Location4 Scales and Balances3 (cont) 0.23 kg (0.5 lb) 0.09 kg (0.2 lb) 0.045 kg (0.1 lb) 0.02 kg (0.05 lb) 9.07 g (0.02 lb) 4.54 g (0.01 lb) 2.27 g (0.005 lb) 0.91 g (0.002 lb) 0.45 g (0.001 lb) (1/16 to 8) oz 25 kg 20 kg 10 kg 5 kg 2 kg 1 kg 500 g 200 g 100 g 50 g 20 g 10 g (1 to 5) g (100 to 500) mg (10 to 50) mg 5 mg 1 mg 2041.2 kg (4500 lb) 1406.1 kg (3100 lb) 2.3 mg 6.7 mg 6.5 mg 2.8 mg 2.7 mg 2.7 mg 2.7 mg 2.7 mg 2.7 mg 64 mg 310 mg 240 mg 140 mg 87 mg 68 mg 65 mg 8.7 mg 4.8 mg 2.4 mg 1.2 mg 0.5 mg 0.27 mg 0.24 mg 0.12 mg 60 µg 24 µg 13 µg 270 g 270 g Class F weights Class F test cart OR, WA OR, WA Force – Measuring Equipment (Tension Only) 5000 lbf Range 10 000 lbf Range Up to 500 lbf (500 to 1000) lbf (1000 to 2000) lbf (2000 to 3000) lbf (3000 to 4000) lbf (4000 to 5000) lbf Up to 2000 lbf (2000 to 4000) lbf (4000 to 6000) lbf (6000 to 8000) lbf (8000 to 10 000) lbf 1.8 lbf 2.5 lbf 2.9 lbf 3.9 lbf 3.2 lbf 3.1 lbf 7 lbf 11 lbf 18 lbf 30 lbf 37 lbf Dillon Wizard w/S-Load cells OR _________________________________
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3601.12) Revised 12/18/2025 Page 3 of 3 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The locations that can perform the calibrations are given by the letter code listed in the table below. The field locations below are service locations and all calibrations are performed at customer sites: Location Code (Main Location) 7933 SW Nimbus Avenue, #28 Beaverton, OR 97008 OR (Field Location) 7031 South 196th Street, Ste 1-3 Kent, WA 98032 WA 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

7933 SW Nimbus #28, Beaverton, OR, 97008, US

45.48717, -122.80378

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.