United States

Thermoworks

741 East Utah Valley Drive, 84003, American Fork, UT, United States

Visit website
A2LA 4024.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
7
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

A2LA certificate 4024.01 · 7 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4024.01) 8/22/2024 Page 2 of 6 Parameter/Equipment Range CMC2, 6 (±) Comments DC Resistance – Measure Bridge Measurement (0 to 1.2) Ω (0 to 12) Ω (0 to 120) Ω (0 to 400) Ω (0 to 10) kΩ (10 to 40) kΩ (40 to 100) kΩ (100 to 500) kΩ Greater of 14 µΩ or 48 µΩ/Ω Greater of 28 µΩ or 12 µΩ/Ω Greater of 40 µΩ or 6 µΩ/Ω Greater of 95 µΩ or 5 µΩ/Ω Greater of 140 µΩ or 6 µΩ/Ω 10 µΩ/Ω 25 µΩ/Ω 95 µΩ/Ω Fluke 1595A resistance bridge DC Resistance – Measure Direct Measurement (0 to 2.0) Ω (> 2 to 20) Ω (> 20 to 200) Ω (> 0.2 to 2.0) kΩ (> 2.0 to 20) kΩ (> 20 to 200) kΩ (> 0.2 to 2.0) MΩ 20 µΩ/Ω + 7.5 µΩ 12 µΩ/Ω + 20 µΩ 12 µΩ/Ω + 100 µΩ 12 µΩ/Ω + 1.0 mΩ 12 µΩ/Ω + 10 mΩ 12 µΩ/Ω + 0.1 Ω 13 µΩ/Ω + 1.0 Ω Fluke 8588A DMM Electrical Calibration of Thermocouple Indicating Devices – Measure and Generate Type E Type J Type K (-270 to < -245) °C (-245 to < -195) °C (-195 to < -155) °C (-155 to < -90) °C (-90 to < 15) °C (15 to < 890) °C (890 to 1000) °C (-210 to < -180) °C (-180 to < -120) °C (-120 to < -50) °C (-50 to 1200) °C (-270 to < -255) °C (-255 to < -195) °C (-195 to < -115) °C (-115 to < -55) °C (-55 to < 1000) °C (1000 to 1372) °C 1.5 °C 0.24 °C 0.12 °C 0.10 °C 0.09 °C 0.07 °C 0.08 °C 0.15 °C 0.12 °C 0.10 °C 0.09 °C 2.8 °C 0.85 °C 0.15 °C 0.11 °C 0.09 °C 0.10 °C Fluke 7526A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4024.01) 8/22/2024 Page 3 of 6 Parameter/Equipment Range CMC2, 6 (±) Comments Electrical Calibration of Thermocouple Indicating Devices – Measure and Generate (cont) Type N Type R Type S Type T (-270 to < -260) °C (-260 to < -200) °C (-200 to < -145) °C (-145 to < -70) °C (-70 to < 25) °C (25 to < 160) °C (160 to 1300) °C (-50 to < -30) °C (-30 to < 45) °C (45 to < 160) °C (160 to < 380) °C (380 to < 775) °C (775 to 1768) °C (-50 to < -30) °C (-30 to < 45) °C (45 to < 105) °C (105 to < 310) °C (310 to < 615) °C (615 to 1768) °C (-270 to < -255) °C (-255 to < -240) °C (-240 to < -210) °C (-210 to < -150) °C (-150 to < -40) °C (-40 to < 100) °C (100 to 400) °C 5.8 °C 1.3 °C 0.28 °C 0.18 °C 0.14 °C 0.12 °C 0.11 °C 0.78 °C 0.66 °C 0.48 °C 0.36 °C 0.31 °C 0.22 °C 0.74 °C 0.67 °C 0.48 °C 0.40 °C 0.35 °C 0.31 °C 2.3 °C 0.59 °C 0.36 °C 0.22 °C 0.14 °C 0.10 °C 0.09 °C Fluke 7526A
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4024.01) 8/22/2024 Page 4 of 6 Parameter/Equipment Range CMC2, 3, 6 (±) Comments Electrical Calibration of Thermocouple Reference Junctions – Measure and Generate Type E, J, K, N, T Type R, S 0 °C (21 to 25) °C 0 °C (21 to 25) °C 0.06 °C 0.06 °C 0.085 °C 0.085 °C Characterized thermocouple or thermocouple reference junction probe (RJP) Electrical Calibration of RTD Indicating Devices – Generate Pt 100 Pt 200 Pt 500 Pt 1000 (-200 to 500) °C (> 500 to 800) °C (-200 to 800) °C (> 500 to 800) °C (-200 to 325) °C (> 325 to 800) °C (-200 to 800) °C (0.006 % + 0.020) °C (0.007 % + 0.018) °C (0.006 % + 0.020) °C (0.007 % + 0.018) °C (0.006 % + 0.016) °C (0.011 % + 0.19) °C (0.0045 % + 0.10) °C IET RTD-Z-6-.001 IET RTD-Z-6-.001 IET RTD-Z-6-.001 Fluke 7526A Fluke 7526A
-200 to 800 °C
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4024.01) 8/22/2024 Page 5 of 6 II. Thermodynamics Parameter/Equipment Range CMC2, 4 (±) Comments Temperature – Measure (-200 to < -80) °C (-80 to < 0) °C 0 °C (> 0 to 100) °C (> 100 to 200) °C (> 200 to 300) °C (> 300 to 420) °C (-200 to < -80) °C (-80 to < 0) °C 0 °C (> 0 to 100) °C (> 100 to 200) °C (> 200 to 300) °C (> 300 to 400) °C (> 400 to 500) °C (> 500 to 600) °C (> 600 to 660) °C 0.0050 °C 0.0060 °C 0.0050 °C 0.0060 °C 0.0075 °C 0.010 °C 0.012 °C 0.009 °C 0.008 °C 0.007 °C 0.009 °C 0.011 °C 0.014 °C 0.016 °C 0.018 °C 0.020 °C 0.023 °C Fluke 1595A with SPRT/TPW cell Fluke 1595A with PRT Temperature – Measuring Equipment (-80 to < 0) °C 0 °C (> 0 to 100) °C (> 100 to 200) °C (> 200 to 300) °C (> 300 to 420) °C (-80 to < 0) °C 0 °C (> 0 to 100) °C (> 100 to 200) °C (> 200 to 300) °C (> 300 to 400) °C (> 400 to 500) °C (> 500 to 600) °C (> 600 to 660) °C 0.0060 °C 0.0050 °C 0.0060 °C 0.0080 °C 0.010 °C 0.012 °C 0.008 °C 0.007 °C 0.009 °C 0.012 °C 0.014 °C 0.016 °C 0.018 °C 0.022 °C 0.025 °C Fluke 1595A with SPRT/TPWcell/bath Fluke 1595A with PRT/baths/dry-block calibrators Non-Contact (IR) Thermometry – Measuring Equipment (-15 to 0) °C 35 °C 100 °C 200 °C 350 °C 500 °C (> 500 to 700) °C 0.60 °C 0.55 °C 0.70 °C 1.0 °C 1.6 °C 2.1 °C 2.5 °C Fluke 4180, Fluke 4181, Isotech R700
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4024.01) 8/22/2024 Page 6 of 6 Parameter/Equipment Range CMC2, 4 (±) Comments Relative Humidity – Measuring Equipment (10 to 50) % RH (> 50 to 75) % RH (> 75 to 90) % RH (15 to 20) °C (> 20 to 25) °C (> 25 to 35) °C 0.55 % RH 0.60 % RH 0.65 % RH 0.060 °C 0.055 °C 0.060 °C Thunder Scientific 2500 humidity generator ________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated.
7ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

741 East Utah Valley Drive, American Fork, UT, 84003, US

40.37681, -111.79591

Open in Maps

Accreditation data refreshed from the A2LA register on .