What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 7 scope lines.
A2LA certificate 4024.01 · 7 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4024.01) 8/22/2024 Page 2 of 6
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
DC Resistance – Measure
Bridge Measurement
(0 to 1.2) Ω
(0 to 12) Ω
(0 to 120) Ω
(0 to 400) Ω
(0 to 10) kΩ
(10 to 40) kΩ
(40 to 100) kΩ
(100 to 500) kΩ
Greater of 14 µΩ or 48 µΩ/Ω
Greater of 28 µΩ or 12 µΩ/Ω
Greater of 40 µΩ or 6 µΩ/Ω
Greater of 95 µΩ or 5 µΩ/Ω
Greater of 140 µΩ or 6 µΩ/Ω
10 µΩ/Ω
25 µΩ/Ω
95 µΩ/Ω
Fluke 1595A
resistance bridge
DC Resistance – Measure
Direct Measurement
(0 to 2.0) Ω
(> 2 to 20) Ω
(> 20 to 200) Ω
(> 0.2 to 2.0) kΩ
(> 2.0 to 20) kΩ
(> 20 to 200) kΩ
(> 0.2 to 2.0) MΩ
20 µΩ/Ω + 7.5 µΩ
12 µΩ/Ω + 20 µΩ
12 µΩ/Ω + 100 µΩ
12 µΩ/Ω + 1.0 mΩ
12 µΩ/Ω + 10 mΩ
12 µΩ/Ω + 0.1 Ω
13 µΩ/Ω + 1.0 Ω
Fluke 8588A DMM
Electrical Calibration of
Thermocouple Indicating
Devices – Measure and
Generate
Type E
Type J
Type K
(-270 to < -245) °C
(-245 to < -195) °C
(-195 to < -155) °C
(-155 to < -90) °C
(-90 to < 15) °C
(15 to < 890) °C
(890 to 1000) °C
(-210 to < -180) °C
(-180 to < -120) °C
(-120 to < -50) °C
(-50 to 1200) °C
(-270 to < -255) °C
(-255 to < -195) °C
(-195 to < -115) °C
(-115 to < -55) °C
(-55 to < 1000) °C
(1000 to 1372) °C
1.5 °C
0.24 °C
0.12 °C
0.10 °C
0.09 °C
0.07 °C
0.08 °C
0.15 °C
0.12 °C
0.10 °C
0.09 °C
2.8 °C
0.85 °C
0.15 °C
0.11 °C
0.09 °C
0.10 °C
Fluke 7526A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4024.01) 8/22/2024 Page 3 of 6
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Electrical Calibration of
Thermocouple Indicating
Devices – Measure and
Generate
(cont)
Type N
Type R
Type S
Type T
(-270 to < -260) °C
(-260 to < -200) °C
(-200 to < -145) °C
(-145 to < -70) °C
(-70 to < 25) °C
(25 to < 160) °C
(160 to 1300) °C
(-50 to < -30) °C
(-30 to < 45) °C
(45 to < 160) °C
(160 to < 380) °C
(380 to < 775) °C
(775 to 1768) °C
(-50 to < -30) °C
(-30 to < 45) °C
(45 to < 105) °C
(105 to < 310) °C
(310 to < 615) °C
(615 to 1768) °C
(-270 to < -255) °C
(-255 to < -240) °C
(-240 to < -210) °C
(-210 to < -150) °C
(-150 to < -40) °C
(-40 to < 100) °C
(100 to 400) °C
5.8 °C
1.3 °C
0.28 °C
0.18 °C
0.14 °C
0.12 °C
0.11 °C
0.78 °C
0.66 °C
0.48 °C
0.36 °C
0.31 °C
0.22 °C
0.74 °C
0.67 °C
0.48 °C
0.40 °C
0.35 °C
0.31 °C
2.3 °C
0.59 °C
0.36 °C
0.22 °C
0.14 °C
0.10 °C
0.09 °C
Fluke 7526A | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4024.01) 8/22/2024 Page 4 of 6
Parameter/Equipment
Range
CMC2, 3, 6 (±)
Comments
Electrical Calibration of
Thermocouple Reference
Junctions – Measure and
Generate
Type E, J, K, N, T
Type R, S
0 °C
(21 to 25) °C
0 °C
(21 to 25) °C
0.06 °C
0.06 °C
0.085 °C
0.085 °C
Characterized
thermocouple or
thermocouple
reference junction
probe (RJP)
Electrical Calibration of
RTD Indicating Devices –
Generate
Pt 100
Pt 200
Pt 500
Pt 1000
(-200 to 500) °C
(> 500 to 800) °C
(-200 to 800) °C
(> 500 to 800) °C
(-200 to 325) °C
(> 325 to 800) °C
(-200 to 800) °C
(0.006 % + 0.020) °C
(0.007 % + 0.018) °C
(0.006 % + 0.020) °C
(0.007 % + 0.018) °C
(0.006 % + 0.016) °C
(0.011 % + 0.19) °C
(0.0045 % + 0.10) °C
IET RTD-Z-6-.001
IET RTD-Z-6-.001
IET RTD-Z-6-.001
Fluke 7526A
Fluke 7526A | -200 to 800 °C |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4024.01) 8/22/2024 Page 5 of 6
II. Thermodynamics
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Temperature – Measure
(-200 to < -80) °C
(-80 to < 0) °C
0 °C
(> 0 to 100) °C
(> 100 to 200) °C
(> 200 to 300) °C
(> 300 to 420) °C
(-200 to < -80) °C
(-80 to < 0) °C
0 °C
(> 0 to 100) °C
(> 100 to 200) °C
(> 200 to 300) °C
(> 300 to 400) °C
(> 400 to 500) °C
(> 500 to 600) °C
(> 600 to 660) °C
0.0050 °C
0.0060 °C
0.0050 °C
0.0060 °C
0.0075 °C
0.010 °C
0.012 °C
0.009 °C
0.008 °C
0.007 °C
0.009 °C
0.011 °C
0.014 °C
0.016 °C
0.018 °C
0.020 °C
0.023 °C
Fluke 1595A with
SPRT/TPW cell
Fluke 1595A with PRT
Temperature – Measuring
Equipment
(-80 to < 0) °C
0 °C
(> 0 to 100) °C
(> 100 to 200) °C
(> 200 to 300) °C
(> 300 to 420) °C
(-80 to < 0) °C
0 °C
(> 0 to 100) °C
(> 100 to 200) °C
(> 200 to 300) °C
(> 300 to 400) °C
(> 400 to 500) °C
(> 500 to 600) °C
(> 600 to 660) °C
0.0060 °C
0.0050 °C
0.0060 °C
0.0080 °C
0.010 °C
0.012 °C
0.008 °C
0.007 °C
0.009 °C
0.012 °C
0.014 °C
0.016 °C
0.018 °C
0.022 °C
0.025 °C
Fluke 1595A with
SPRT/TPWcell/bath
Fluke 1595A with
PRT/baths/dry-block
calibrators
Non-Contact (IR)
Thermometry –
Measuring Equipment
(-15 to 0) °C
35 °C
100 °C
200 °C
350 °C
500 °C
(> 500 to 700) °C
0.60 °C
0.55 °C
0.70 °C
1.0 °C
1.6 °C
2.1 °C
2.5 °C
Fluke 4180, Fluke
4181, Isotech R700 | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4024.01) 8/22/2024 Page 6 of 6
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Relative Humidity –
Measuring Equipment
(10 to 50) % RH
(> 50 to 75) % RH
(> 75 to 90) % RH
(15 to 20) °C
(> 20 to 25) °C
(> 25 to 35) °C
0.55 % RH
0.60 % RH
0.65 % RH
0.060 °C
0.055 °C
0.060 °C
Thunder Scientific
2500 humidity
generator
________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 This scope meets A2LA’s P112 Flexible Scope Policy.
6 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. | ||
| 7 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- SIMCO Electronics - Salt Lake CityDraper, UT · ~17 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Western States CalibrationSalt Lake City, UT · ~43 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Sensor CalibrationsKaysville, UT · ~74 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - DenverLongmont, CO · ~568 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- BHD Test & MeasurementThornton, CO · ~582 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.