FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
United Kingdom

Olfasense UK

Unit 7, Anglo Office Park, BS15 1NT, Bristol, United Kingdom

UKAS|2430ISO/IEC 17025Register refreshed 2026-10-09
Certificates
1
Scope items
5
Standards
7
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Olfasense UK?

Claim this profile to keep it accurate.

Register record

UKASRefreshed
2430Active

Accredited standards

7

Our reading of the UKAS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

EN 1911Stationary source emissions - Determination of mass concentration of gaseous chlorides expressed as HCl - Standard reference method
As written on the certificate · Line 4 (UKAS 2430)

BS EN ISO 21877:2019; BS EN 15259:2007 Ammonia BS EN ISO 21877:2019; BS EN 1911:2010; BS EN 13725:2022; BS EN 14790:2017

EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
As written on the certificate · Line 5 (UKAS 2430)

BS EN 15259:2007; BS EN 12619:2013; BS EN 16911-1:2013; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025

EN 13725Name not checked yet
As written on the certificate · Line 2 (UKAS 2430)

BS EN 13725:2022; BS EN 13725:2022 Ambient Air Process Emissions Point source sampling using: - Lung method - Dynamic dilution C Surface Emissions Area source sampling with outward flow using: - Sheet Method C Surface Emissions Area source sampling without outward flow using: - Lindvall Hood Method - Inverted Lindvall Hood Method - Sheet Method C Ambient Air Process Emissions Surface Emissions Hydrogen Sulphide Sampling direct from source or sample bag onto activated carbon using in-house procedure QD024 based on PD CEN/TS 13649:2014 C Ambient Air Process Emissions Surface Emissions Ammonia Sampling direct from source or sample bag by desorption onto silica gel using in-house procedure QD024 based on NIOSH 6016; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025; IEC 17025

As written on the certificate · Line 3 (UKAS 2430)

BS EN 15259:2007 Ammonia Sampling direct from source or sample bag by desorption onto silica gel using in-house procedure QD024 based on NIOSH 6016 C Ammonia Hydrogen Chloride Sampling direct from source or sample bag with Sorptive sampling method followed by solvent extraction or thermal desorption using in-house procedure QD024 based on PD CEN/TS 13649:2013; BS EN 13725:2022; BS EN 16911-1:2013; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025

As written on the certificate · Line 4 (UKAS 2430)

BS EN ISO 21877:2019; BS EN 15259:2007 Ammonia BS EN ISO 21877:2019; BS EN 1911:2010; BS EN 13725:2022; BS EN 14790:2017

EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
As written on the certificate · Line 4 (UKAS 2430)

BS EN ISO 21877:2019; BS EN 15259:2007 Ammonia BS EN ISO 21877:2019; BS EN 1911:2010; BS EN 13725:2022; BS EN 14790:2017

EN 15259Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
As written on the certificate · Line 3 (UKAS 2430)

BS EN 15259:2007 Ammonia Sampling direct from source or sample bag by desorption onto silica gel using in-house procedure QD024 based on NIOSH 6016 C Ammonia Hydrogen Chloride Sampling direct from source or sample bag with Sorptive sampling method followed by solvent extraction or thermal desorption using in-house procedure QD024 based on PD CEN/TS 13649:2013; BS EN 13725:2022; BS EN 16911-1:2013; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025

As written on the certificate · Line 4 (UKAS 2430)

BS EN ISO 21877:2019; BS EN 15259:2007 Ammonia BS EN ISO 21877:2019; BS EN 1911:2010; BS EN 13725:2022; BS EN 14790:2017

As written on the certificate · Line 5 (UKAS 2430)

BS EN 15259:2007; BS EN 12619:2013; BS EN 16911-1:2013; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025

EN 16911-1Name not checked yet
As written on the certificate · Line 3 (UKAS 2430)

BS EN 15259:2007 Ammonia Sampling direct from source or sample bag by desorption onto silica gel using in-house procedure QD024 based on NIOSH 6016 C Ammonia Hydrogen Chloride Sampling direct from source or sample bag with Sorptive sampling method followed by solvent extraction or thermal desorption using in-house procedure QD024 based on PD CEN/TS 13649:2013; BS EN 13725:2022; BS EN 16911-1:2013; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025

As written on the certificate · Line 5 (UKAS 2430)

BS EN 15259:2007; BS EN 12619:2013; BS EN 16911-1:2013; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025

ISO 21877Stationary source emissions— Determination of the mass concentration of ammonia - Manual method
As written on the certificate · Line 4 (UKAS 2430)

BS EN ISO 21877:2019; BS EN 15259:2007 Ammonia BS EN ISO 21877:2019; BS EN 1911:2010; BS EN 13725:2022; BS EN 14790:2017

Scope as published by UKAS

5 lines
UKAS

ISO/IEC 17025

Active

2430

View scope

Accredited scope, certificate 2430

LineDisciplineMethodMatrixRange
1-ISO/IEC 17025:2017--
2environmentalBS EN 13725:2022; BS EN 13725:2022 Ambient Air Process Emissions Point source sampling using: - Lung method - Dynamic dilution C Surface Emissions Area source sampling with outward flow using: - Sheet Method C Surface Emissions Area source sampling without outward flow using: - Lindvall Hood Method - Inverted Lindvall Hood Method - Sheet Method C Ambient Air Process Emissions Surface Emissions Hydrogen Sulphide Sampling direct from source or sample bag onto activated carbon using in-house procedure QD024 based on PD CEN/TS 13649:2014 C Ambient Air Process Emissions Surface Emissions Ammonia Sampling direct from source or sample bag by desorption onto silica gel using in-house procedure QD024 based on NIOSH 6016; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025; IEC 17025Air-
3environmentalBS EN 15259:2007 Ammonia Sampling direct from source or sample bag by desorption onto silica gel using in-house procedure QD024 based on NIOSH 6016 C Ammonia Hydrogen Chloride Sampling direct from source or sample bag with Sorptive sampling method followed by solvent extraction or thermal desorption using in-house procedure QD024 based on PD CEN/TS 13649:2013; BS EN 13725:2022; BS EN 16911-1:2013; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO/IEC 17025Stack emissions to atmosphereto 5 m/sec
4environmentalBS EN ISO 21877:2019; BS EN 15259:2007 Ammonia BS EN ISO 21877:2019; BS EN 1911:2010; BS EN 13725:2022; BS EN 14790:2017Water-
5environmentalBS EN 15259:2007; BS EN 12619:2013; BS EN 16911-1:2013; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025Stack emissions to atmosphere0 to 1000 mg/m³

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Unit 7, Anglo Office Park, Bristol, BS15 1NT, GB

51.45380, -2.59730

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.