United States

Midwest Metrology

341 Smith Drive, 45315, Clayton, OH, United States

Visit website
A2LA 1577.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
16
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 16 scope lines.

A2LA certificate 1577.01 · 16 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 12 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1577.01) 2/26/2025 Page 2 of 15 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Generate3 (0 to 220) mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 8 μV/V + 0.6 μV 7 μV/V + 1.0 μV 6.8 μV/V + 5.7 μV 7 μV/V + 7 μV 9.1 μV/V + 130 μV 8.4 μV/V + 1.2 mV Fluke 5700A DC Voltage – Measure3 (1 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 60) kV 5.4 μV/V + 0.4 μV 4.4 μV/V + 0.5 μV 4.5 μV/V + 1.6 μV 3.7 μV/V + 34 μV 15 μV/V + 42 μV 3.0 mV/V + 6.8 μV Agilent 3458A opt 002 Ross VD-60 w/ DMM DC Current – Measure3 (1 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 20) A 22 μA/A + 800 pA 20 μA/A + 5.3 nA 21 μA/A + 50 nA 36 μA/A + 490 nA 110 μA/A + 10 μA 110 μA/A + 13 μA Agilent 3458A opt 002 Agilent 3458A, Fluke Y5020A DC Current – Generate3 Clamp Meters (0 to 220) μA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (0.22 to 2.2) A (2.2 to 11) A (10 to 1000) A 50 μA/A + 8 nA 47 μA/A + 15 nA 48 μA/A + 0.13 μA 60 μA/A + 0.89 μA 79 μA/A + 27 μA 360 μA + 480 μA 3.5 mA/A + 13 mA Fluke 5700A Fluke 5700A/5725A Fluke 5500A w/ coil Resistance – Measure3 (0.01 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ 9 μΩ/Ω + 170 μΩ 14 μΩ/Ω + 490 μΩ 12 μΩ/Ω + 550 μΩ 12 μΩ/Ω + 4.7 mΩ 13 μΩ/Ω + 45 mΩ 18 μΩ/Ω + 2 Ω 53 μΩ/Ω + 110 Ω 0.49 mΩ/Ω + 2.5 kΩ 5 mΩ/Ω + 14 kΩ Agilent 3458A opt 002
to 1000 A
3Ohms Law Method-See scope document
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1577.01) 2/26/2025 Page 4 of 15 Parameter/Range Frequency CMC2, 4, 5 (±) Comments Capacitance – Generate3 Fixed Points – 0.001 µF 0.01 µF 0.1 µF 10 pF to 1 µF (220 to 399.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.099 99) nF (11 to 32.9999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) μF (1.1 to 3.299 99) μF (3.3 to 10.9999) μF (11 to 32.9999) μF (33 to 109.999) μF (110 to 329.999) μF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF @ 1 kHz @ 1 kHz (0.01 to 10) kHz (0.01 to 10) kHz (0.01 to 3) kHz (0.01 to 1) kHz (0.01 to 1) kHz (0.01 to 1) kHz (0.01 to 1) kHz (0.01 to 600) Hz (0.01 to 300) Hz (0.01 to 150) Hz (0.01 to 120) Hz (0.01 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.53 pF 5.2 pF 51 pF 0.053 % + 0.5 pF 0.49 % + 10 pF 0.49 % + 10 pF 0.5 % + 10 pF 0.25 % + 10 pF 0.25 % + 100 pF 0.26 % + 99 pF 0.26 % + 290 pF 0.26 % + 1 nF 0.26 % + 3 nF 0.26 % + 10 nF 0.41 % + 29 nF 0.47 % + 96 nF 0.46 % + 300 nF 0.45 % + 1.1 μF 0.45 % + 3 μF 0.44 % + 11 μF 0.75 % + 30 μF 1.1 % + 100 μF GR 1409 standard capacitors GR 1413-decade capacitor Fluke 5500A Capacitance – Measure3 (1 to 10) pF (10 to 100) pF 100 pF to 25 μF (25 to 100) μF (100 to 1000) μF 1 pF to 1000 nF 12 Hz to 100 kHz 1 kHz 0.026 % + 0.6 fF 0.029 % + 0.3 fF 0.023 % + 3 fF 0.024 % 0.035 % + 11 nF 2.7 µF/F GR 1689M CMC valid at 1 kHz only. Lab uses IET calculator for other frequencies AH2500A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1577.01) 2/26/2025 Page 5 of 15 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (0.22 to 2.2) mV (2.2 to 22) mV (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz 0.55 mV/V + 4.5 μV 0.21 mV/V + 4.5 μV 0.11 mV/V + 4.5 μV 0.37 mV/V + 4.5 μV 0.85 mV/V + 7 μV 1.1 mV/V + 13 μV 1.7 mV/V + 25 μV 3.4 mV/V + 25 μV 0.55 mV/V + 5 μV 0.21 mV/V + 5 μV 0.11 mV/V + 5 μV 0.37 mV/V + 5 μV 0.85 mV/V + 7 μV 1.1 mV/V + 12 μV 1.7 mV/V + 25 μV 3.4 mV/V + 25 μV 0.44 mV/V + 44 μV 0.21 mV/V + 8.5 μV 0.11 mV/V + 8 μV 0.32 mV/V + 8 μV 0.85 mV/V + 25 μV 1.1 mV/V + 25 μV 1.7 mV/V + 35 μV 3.4 mV/V + 80 μV 450 μV/V + 340 μV 160 μV/V + 29 μV 75 μV/V + 6.2 μV 120 μV/V + 16 μV 250 μV/V + 70 μV 420 μV/V + 130 μV 1.1 mV/V + 350 μV 2.2 mV/V + 850 μV 0.37 mV/V + 4.3 mV 160 μV/V + 310 μV 75 μV/V + 62 μV 120 μV + 160 μV 250 μV/V + 350 μV 0.5 mV/V + 1.5 mV 1.3 mV/V + 4.3 mV 2.7 mV/V + 8.5 mV Fluke 5700A/5725A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1577.01) 2/26/2025 Page 6 of 15 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate (cont) (22 to 220) V (220 to 250) V (220 to 1100) V (220 to 750) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz (0.5 to 1) MHz (15 to 50) Hz 50 Hz to 1 kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz 0.49 mV/V + 9.9 mV 0.16 mV/V + 2.5 mV 80 μV/V + 810 μV 0.22 mV/V + 3.5 mV 0.5 mV/V + 8 mV 1.5 mV/V + 90 mV 4.7 mV/V + 90 mV 12 mV/V + 190 mV 40 μV/V + 17 mV 80 μV/V + 3.9 mV 90 μV/V + 4.4 mV 0.17 mV/V + 6.1 mV 0.6 mV/V + 11 mV 0.6 mV/V + 11 mV 2.2 mV/V + 180 mV Fluke 5700A Fluke 5700A/5725A AC Voltage – Measure3 (1 to 10) mV (10 to 100) mV 100 mV to 1 V 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 4) MHz (4 to 8) MHz (8 to 10) MHz 0.16 mV/V + 2 μV 0.24 mV/V + 2 μV 0.94 mV/V + 2 μV 5 mV/V + 1.5 μV 40 mV/V + 2 μV 72 μV/V + 2 μV 0.14 mV/V + 2 μV 0.3 mV/V + 2 μV 0.8 mV/V + 2 μV 3 mV/V + 10 μV 59 μV/V + 39 μV 130 μV/V + 37 μV 0.29 mV/V + 33 μV 0.79 mV/V + 27 μV 3 mV/V + 0.1 mV 10 mV/V + 0.1 mV 40 mV/V + 0.7 mV 41 mV/V + 0.17 μV 150 mV/V + 1 mV Agilent 3458A opt 002/H01
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1577.01) 2/26/2025 Page 7 of 15 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure3 (cont) (1 to 10) V (10 to 100) V (100 to 700) V (1 to 42) kV 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz (1 to 4) MHz (4 to 8) MHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz 60 Hz 73 μV/V + 0.2 mV 140 μV/V + 0.2 mV 0.2 mV/V + 0.3 mV 0.8 mV/V + 0.2 mV 3 mV/V + 1 mV 10 mV/V + 1 mV 40 mV/V + 7 mV 40 mV/V + 8 mV 0.2 mV/V + 2 mV 0.2 mV/V + 2 mV 0.42 mV/V + 3 mV 1.2 mV/V + 2 mV 4 mV/V + 10 mV 15 mV/V + 10 mV 0.4 mV/V + 23 mV 0.6 mV/V + 20 mV 1.2 mV/V + 20 mV 5.0 mV/V + 1 V Agilent 3458A opt 002/H01 Ross VD-60 w/ DMM AC Current – Measure3 (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz 1.5 mA/A + 30 nA 0.6 mA/A + 30 nA 0.6 mA/A + 30 nA 1.5 mA/A + 0.21 μA 0.6 mA/A + 0.21 μA 0.29 mA/A + 0.21 μA 0.59 mA/A + 0.21 μA 4.8 mA/A + 0.33 μA 5.5 mA/A + 1.5 μA 1.5 mA/A + 2.1 μA 0.59 mA/A + 2.1 μA 0.29 mA/A + 2.1 μA 0.59 mA/A + 2.1 μA 4 mA/A + 4 μA 5.5 mA/A + 15 μA Agilent 3458A opt 002
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1577.01) 2/26/2025 Page 8 of 15 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Measure3 (cont) (10 to 100) mA (0.1 to 1) A (0 to 20) A (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (20 to 45) Hz (45 to 100) Hz (0.1 to 5) kHz (5 to 20) kHz (20 to 50) kHz (45 to 100) Hz (0.1 to 1) kHz 1.5 mA/A + 21 μA 0.59 mA/A + 21 μA 0.29 mA/A + 21 μA 0.59 mA/A + 21 μA 4 mA/A + 40 μA 5.5 mA/A + 150 μA 1.6 mA/A + 0.2 mA 0.81 mA/A + 0.2 mA 1 mA/A + 0.2 mA 3 mA/A + 0.2 mA 10 mA/A + 0.4 mA 0.23 mA/A + 1.9 mA 0.35 mA/A + 1.8 mA Agilent 3458A opt 002/H01 Agilent 3458A, Fluke Y5020 AC Current – Generate3 (10 to 220) μA (0.22 to 2.2) mA (2.2 to 22) mA (22 to 220) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.7 mA/A + 25 nA 0.35 mA/A + 20 nA 0.14 mA/A + 16 nA 0.6 mA/A + 40 nA 1.6 mA/A + 80 nA 0.70 mA/A + 41 nA 0.35 mA/A + 35 nA 0.14 m/A + 35 nA 0.6 mA/A + 0.4 μA 1.6 mA/A + 0.8 μA 0.7 mA/A + 0.43 μA 0.35 mA/A + 0.35 μA 0.14 mA/A + 0.35 μA 0.8 mA/A + 2 μA 1.6 mA/A + 8 μA 0.7 mA/A + 4.3 μA 0.35 mA/A + 3.5 μA 0.14 mA/A + 3.5 μA 0.6 mA/A + 40 μA 1.6 mA/A + 80 μA Fluke 5700A, Fluke 5522A Fluke 5700A/5725A, Fluke 5522A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1577.01) 2/26/2025 Page 9 of 15 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (cont) (0.22 to 2.2) A (2.2 to 11) A (20 to 500) A 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz (100 to 440) Hz 0.26 mA/A + 39 μA 0.75 mA/A + 80 μA 8.5 mA/A + 0.16 mA 0.46 mA/A + 0.17 mA 0.95 mA/A + 0.38 mA 3.6 mA/A + 0.75 mA 1.6 mA/A + 0.2 A 10 mA/A + 0.11 A Fluke 5700A Fluke 5700A/5725A Fluke 5522A w/ coil Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators & Indicating Systems3 – Type E Type J Type K Type N (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C 0.5 °C 0.17 °C 0.15 °C 0.17 °C 0.21 °C 0.27 °C 0.17 °C 0.15 °C 0.17 °C 0.23 °C 0.33 °C 0.18 °C 0.17 °C 0.26 °C 0.4 °C 0.4 °C 0.22 °C 0.19 °C 0.18 °C 0.27 °C Fluke 5522A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1577.01) 2/26/2025 Page 10 of 15 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators & Indicating Systems3 – (cont) Type R Type S Type T (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.57 °C 0.35 °C 0.33 °C 0.4 °C 0.47 °C 0.36 °C 0.37 °C 0.46 °C 0.63 °C 0.24 °C 0.17 °C 0.15 °C Fluke 5522A Electrical Calibration of RTD Indicators & Indicating Systems 3 – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω (-200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (200 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.05 °C 0.07 °C 0.09 °C 0.10 °C 0.12 °C 0.23 °C 0.05 °C 0.07 °C 0.09 °C 0.10 °C 0.12 °C 0.25 °C 0.04 °C 0.05 °C 0.06 °C 0.07 °C 0.08 °C 0.09 °C 0.10 °C 0.23 °C Fluke 5522A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1577.01) 2/26/2025 Page 11 of 15 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicators & Indicating Systems3 – (cont) Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω Pt 385, 120 Ω (Ni 120) Cu 427, 10 Ω (-200 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 600) °C (600 to 630) °C (-80 to 100) °C (100 to 260) °C (-100 to 260) °C 0.04 °C 0.05 °C 0.12 °C 0.13 °C 0.14 °C 0.16 °C 0.04 °C 0.05 °C 0.06 °C 0.07 °C 0.08 °C 0.09 °C 0.11 °C 0.03 °C 0.04 °C 0.05 °C 0.05 °C 0.07 °C 0.23 °C 0.08 °C 0.14 °C 0.3 °C Fluke 5522A Parameter/Range Frequency CMC2 (±) Comments Oscilloscope3 – Level Sine Wave 5 mV to 5.5 V(p-p) Leveled Sine Flatness 5 mV to 5.5 V(p-p) Relative to 50 kHz Reference 50 kHz reference (0.5 to 100) MHz (0.1 to 0.3) GHz (0.3 to 0.6) GHz 16 mV/V + 230 μV 12 mV/V + 200 μV 18 mV/V + 220 μV 32 mV/V + 360 μV Fluke 5500A w/ SC600 option
12ASTM Class 1; NIST Class F-See scope document
13ASTM Class 6-See scope document
14--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1577.01) 2/26/2025 Page 14 of 15 Parameter/Equipment Range CMC2, 5, 6 (±) Comments Relative Humidity3 – Measuring Equipment Measure (10 to 95) % RH (10 to 90) % RH 0.002 % + 0.48 % RH 1.1 % RH Thunder Scientific 1200 humidity generator Standard RH probe V. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment 10 MHz 1 nHz/Hz ArgoSystems AS210 rubidium Frequency – Measure3 0.1 Hz to 3 GHz 1 nHz/Hz Agilent 53132A referenced to GPS/rubidium source Stopwatches – Digital3 32.768 kHz 0.063 Hz HP 5335A w/ wave analyzer ____________________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
10 to 95 % RH
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1577.01) 2/26/2025 Page 15 of 15 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
16ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

341 Smith Drive, Clayton, OH, 45315, US

39.86311, -84.36050

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.