Cerpass Technology Corporation (Cerpass Laboratory Dongguan)
Room 102, No. 5, Xing' an Road, Chang' an Town, Dongguan City, Guangdong Provice, 523847, People's Republic of China, Dongguan City, Guangdong Provice, China
Visit website- Accredited standards
- 53
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 53 standard numbers and the 30 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI22
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 386
ETSI EN 300 440
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-4
ETSI EN 301 489-5
ETSI EN 301 489-7
ETSI EN 301 489-9
Show all 22
ETSI EN 301 489-17
ETSI EN 301 489-20
ETSI EN 301 489-23
ETSI EN 301 489-26
ETSI EN 301 489-33
ETSI EN 301 489-34
ETSI EN 301 489-35
ETSI EN 301 893
ETSI EN 302 208
ETSI EN 302 502
IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+1 national
National versions in the same scope
AS/NZS 61000.4.2probably the same standard; matched by number only
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+1 national
National versions in the same scope
AS/NZS 61000.4.3probably the same standard; matched by number only
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test+1 national
National versions in the same scope
AS/NZS 61000.4.4probably the same standard; matched by number only
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test+1 national
National versions in the same scope
AS/NZS 61000.4.5probably the same standard; matched by number only
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields+1 national
National versions in the same scope
AS/NZS 61000.4.6probably the same standard; matched by number only
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test+1 national
National versions in the same scope
AS/NZS 61000.4.8probably the same standard; matched by number only
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase+1 national
National versions in the same scope
AS/NZS 61000.4.11probably the same standard; matched by number only
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national
National versions in the same scope
AS/NZS CISPR 32identical to it
VCCI-CISPR 32probably the same standard; matched by number only
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC 61326 series6
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-4
IEC 61326-2-5
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC3
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
Other standards3
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50364
FCC PART 15Radio Frequency Devices
IEC/EN 61000-4-8; AS/NZS 61000.4.8; IEC/EN 61000-4-11; AS/NZS 61000.4.11; IEC/EN 61000-6-1; IEC/EN 61000-6-2; IEC/EN 61000-6-3; IEC/EN 61000-6-4; EN 55014-2; CISPR 14-2; EN 55024; CISPR 24; EN 55035; CISPR 35; EN 50130-4; EN 60601-1-2; EN 61326-2-1; EN 61326-2-2; EN 61326-2-3; EN 61326-2-4; EN 61326-2-5; EN 61326-2-6; EN 301 489-1; EN 301 489-3; EN 301 489-4; EN 301 489-5; EN 301 489-7; EN 301 489-9; EN 301 489-17; EN 301 489-20; EN 301 489-23; EN 301 489-26; EN 301 489-33; EN 301 489-34; EN 301 489-35; EN 300 386; EN 300 220-1; EN 300 220-2; EN 300 330; EN 302 208; EN 300 440; EN 301 893; EN 302 502; EN 300 328; CFR 47, FCC Parts 15 C, E, and F; ANSI C63.10:2020; FCC KDB 905462 D02 (v02) April 08, 2016; ANSI C63.10:2013; ANSI C63.10-2020 + Cor. 1-2023 + C63.10a-2024 + Errata to C63.10a-2024; ANSI C63.26; CFR 47, FCC Part 22; CFR 47, FCC Part 24 (Subpart E); CFR 47, FCC Part 25 (below 3 GHz); CFR 47, FCC Part 27 (Subparts L & M); ANSI/TIA-603-E; ANSI/TIA 102.CAAA-E; RSS-GEN; RSS-132; RSS-133; RSS-134; RSS-139; RSS- 210 (< 40 GHz); RSS-216 (< 40 GHz); RSS-247; RSS-310; AS/NZS 4268
CFR 47, FCC Part 15 B (using ANSI C63.4:2014); CFR 47, FCC Part 18 (using MP-5:1986); CISPR 11; EN 55011; CISPR 14-1; EN 55014-1; CISPR 32; EN 55032; AS/NZS CISPR 32; ICES-GEN; ICES-001; ICES-003; ICES-005; BETS-7; VCCI-CISPR 32; J 55014-1; IEC/EN 61000-3-2; AS/NZS 61000.3.2; IEC/EN 61000-3-3; AS/NZS 61000.3.3; IEC/EN 61000-4-2; AS/NZS 61000.4.2; IEC/EN 61000-4-3; AS/NZS 61000.4.3; IEC/EN 61000-4-4; AS/NZS 61000.4.4; IEC/EN 61000-4-5; AS/NZS 61000.4.5; IEC/EN 61000-4-6; AS/NZS 61000.4.6
EN 62479; EN 62311; EN 50364; IEEE C95.1; IEEE C95.3; KDB 447498 (D01); ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; FCC KDB 905462 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E
Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-06.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active4981.01
The scope document we hold says it is valid until 2028-08-31.
Accredited scope, certificate 4981.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CFR 47, FCC Part 15 B (using ANSI C63.4:2014); CFR 47, FCC Part 18 (using MP-5:1986); CISPR 11; EN 55011; CISPR 14-1; EN 55014-1; CISPR 32; EN 55032; AS/NZS CISPR 32; ICES-GEN; ICES-001; ICES-003; ICES-005; BETS-7; VCCI-CISPR 32; J 55014-1; IEC/EN 61000-3-2; AS/NZS 61000.3.2; IEC/EN 61000-3-3; AS/NZS 61000.3.3; IEC/EN 61000-4-2; AS/NZS 61000.4.2; IEC/EN 61000-4-3; AS/NZS 61000.4.3; IEC/EN 61000-4-4; AS/NZS 61000.4.4; IEC/EN 61000-4-5; AS/NZS 61000.4.5; IEC/EN 61000-4-6; AS/NZS 61000.4.6 | - | - |
| 2 | IEC/EN 61000-4-8; AS/NZS 61000.4.8; IEC/EN 61000-4-11; AS/NZS 61000.4.11; IEC/EN 61000-6-1; IEC/EN 61000-6-2; IEC/EN 61000-6-3; IEC/EN 61000-6-4; EN 55014-2; CISPR 14-2; EN 55024; CISPR 24; EN 55035; CISPR 35; EN 50130-4; EN 60601-1-2; EN 61326-2-1; EN 61326-2-2; EN 61326-2-3; EN 61326-2-4; EN 61326-2-5; EN 61326-2-6; EN 301 489-1; EN 301 489-3; EN 301 489-4; EN 301 489-5; EN 301 489-7; EN 301 489-9; EN 301 489-17; EN 301 489-20; EN 301 489-23; EN 301 489-26; EN 301 489-33; EN 301 489-34; EN 301 489-35; EN 300 386; EN 300 220-1; EN 300 220-2; EN 300 330; EN 302 208; EN 300 440; EN 301 893; EN 302 502; EN 300 328; CFR 47, FCC Parts 15 C, E, and F; ANSI C63.10:2020; FCC KDB 905462 D02 (v02) April 08, 2016; ANSI C63.10:2013; ANSI C63.10-2020 + Cor. 1-2023 + C63.10a-2024 + Errata to C63.10a-2024; ANSI C63.26; CFR 47, FCC Part 22; CFR 47, FCC Part 24 (Subpart E); CFR 47, FCC Part 25 (below 3 GHz); CFR 47, FCC Part 27 (Subparts L & M); ANSI/TIA-603-E; ANSI/TIA 102.CAAA-E; RSS-GEN; RSS-132; RSS-133; RSS-134; RSS-139; RSS- 210 (< 40 GHz); RSS-216 (< 40 GHz); RSS-247; RSS-310; AS/NZS 4268 | - | to 40 GHz |
| 3 | EN 62479; EN 62311; EN 50364; IEEE C95.1; IEEE C95.3; KDB 447498 (D01); ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2020; FCC KDB 905462 (v02); ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E | Telecommunications Terminal Equipment (TTE); Radio Equipment; Network Equipment; Information Technology Equipment (ITE); Radiocommunication Equipment and Systems; Medical Electrical Equipment; Industrial, Scientific and Medical (ISM) Radio-Frequency Equipment; Electrical Equipment for Measurement | to 40000 MHz |
| 4 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in China
- Dongguan DN Testing Co.,DongguanA2LAShares 1 accredited test methodCISPR 11
- Dongguan New Testing Centre Co.,DongguanA2LAShares 1 accredited test methodCISPR 11
- Dongguan Yaxu (AiT) TechnologyDongguan, GuangdongA2LAShares 1 accredited test methodCISPR 11
- MRT Technology (Shenzhen) Co.,Shenzhen, GuangdongA2LAShares 1 accredited test methodCISPR 11
- MRT Technology (Suzhou) Co.,Suzhou, JiangsuA2LAShares 1 accredited test methodCISPR 11
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.