Meadowlark Mechanical

Kalama, WA, United States

Visit website
A2LA 7066.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
6
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 7066.01 · 6 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 100 mV
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7066.01) 5/14/2025 Page 2 of 5 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation of Thermocouples3 Type J Type K Type T (-200 to 0) °C (>0 to 1200) °C (-200 to 0) °C (>0 to 1370) °C (-200 to 0) °C (>0 to 400) °C 0.64 °C 0.54 °C 0.80 °C 0.65 °C 0.80 °C 0.38 °C Fluke process calibrator Electrical Simulation of RTDs3 Pt100-385 (-200 to 0) °C (>0 to 800) °C 0.21 °C 0.36 °C Fluke process calibrator Electrical Simulation of Relative Humidity 3 Applied mA Applied V Up to 100 % RH Up to 100 % RH 0.03 % RH 0.068 % RH Fluke process calibrator III. Thermodynamics Parameter/Equipment Range CMC2, 5, 9 (±) Comments Temperature – Measure3 Type J Type K Type T (0 to 400) °C (0 to 500) °C (-80 to 0) °C (>0 to 200) °C 1.4 °C 1.2 °C 1.2 °C 1.2 °C Fluke process calibrator & thermocouple
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7066.01) 5/14/2025 Page 3 of 5 Parameter/Equipment Range CMC2, 5, 6, 7, 8, 9 (±) Comments Temperature – Thermal Uniformity Survey3 Type J Type K Type T (0 to 400) °C (0 to 500) °C (-80 to 0) °C (>0 to 200) °C 1.8 °C 1.8 °C 1.4 °C 1.6 °C Fluke process calibrator & thermocouple Temperature – Chamber/Oven/Freezer/U LTs 3 Bench-Top: Type J Type K Type T Reach-In: Type J Type K Type T Walk-In: Type J Type K Type T (0 to 400) °C (0 to 500) °C (-80 to 0) °C (>0 to 200) °C (0 to 400) °C (0 to 500) °C (-80 to 0) °C (>0 to 200) °C (0 to 400) °C (0 to 500) °C (-80 to 0) °C (>0 to 200) °C 1.4 °C 1.0 °C 1.2 °C 1.2 °C 1.4 °C 1.2 °C 1.2 °C 1.2 °C 1.4 °C 1.2 °C 1.2 °C 1.2 °C Fluke process calibrator & thermocouple Humidity – Measure3 (0.4 to 35) %RH (>35 to 80) %RH (>80 to 96) %RH 0.98 % RH 0.0071H + 0.73 % RH 1.3 % RH Rotronic HC2A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7066.01) 5/14/2025 Page 4 of 5 Parameter/Equipment Range CMC2, 6, 8 (±) Comments Humidity – Chamber3 Bench-Top Reach-In Walk-In (0.4 to 35) %RH (>35 to 80) %RH (>80 to 96) %RH (0.4 to 35) %RH (>35 to 80) %RH (>80 to 96) %RH (0.4 to 35) %RH (>35 to 80) %RH (>80 to 96) %RH 0.98 % RH 0.0071H + 0.73 % RH 1.3 % RH 0.98 % RH 0.0071H + 0.73 % RH 1.3 % RH 0.97 % RH 0.0071H + 0.73 % RH 1.3 % RH Rotronic HC2A ____________________________________________ 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards of n early ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 Field temperature measurements made outside environmental conditions between 18 °C to 28 °C (65 °F to 82 °F), shall include additional an uncertainty of 0.05T where T is the difference in temperature outside of 18 °C to 28 °C. 6 Field humidity measurements made outside environmental conditions between 10 °C to 30 °C (50 °F to 86 °F), shall include additional an uncertainty of +0.5 % RH between -10 °C to 50 °C, +2.5 % RH between -50 °C to -30 °C, +1.5 % RH between -30 °C to -10 °C, and +1 % RH between 50 °C to 70 °C. Refer to OEM specifications for additional temperature ranges. 7 Field measurements made with the Fluke Process Calibrator outside environmental conditions between 18 °C to 28 °C (65 °F to 82 °F), shall include additional an uncertainty of 0.005 %/°C.
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7066.01) 5/14/2025 Page 5 of 5 8 H is the value in % RH for range (>35 to 80) % RH. 9 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 10 This scope meets A2LA’s P112 Flexible Scope Policy.
35 to 80 % RH
6ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Kalama, WA, US

46.00852, -122.84247

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.