Meadowlark Mechanical
Kalama, WA, United States
Visit website- Scope lines
- 6
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 7066.01 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 100 mV |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7066.01) 5/14/2025 Page 2 of 5
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Simulation of
Thermocouples3
Type J
Type K
Type T
(-200 to 0) °C
(>0 to 1200) °C
(-200 to 0) °C
(>0 to 1370) °C
(-200 to 0) °C
(>0 to 400) °C
0.64 °C
0.54 °C
0.80 °C
0.65 °C
0.80 °C
0.38 °C
Fluke process
calibrator
Electrical Simulation of
RTDs3
Pt100-385
(-200 to 0) °C
(>0 to 800) °C
0.21 °C
0.36 °C
Fluke process
calibrator
Electrical Simulation of
Relative Humidity
3
Applied mA
Applied V
Up to 100 % RH
Up to 100 % RH
0.03 % RH
0.068 % RH
Fluke process
calibrator
III. Thermodynamics
Parameter/Equipment
Range
CMC2, 5, 9 (±)
Comments
Temperature – Measure3
Type J
Type K
Type T
(0 to 400) °C
(0 to 500) °C
(-80 to 0) °C
(>0 to 200) °C
1.4 °C
1.2 °C
1.2 °C
1.2 °C
Fluke process
calibrator &
thermocouple | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7066.01) 5/14/2025 Page 3 of 5
Parameter/Equipment
Range
CMC2, 5, 6, 7, 8, 9 (±)
Comments
Temperature – Thermal
Uniformity Survey3
Type J
Type K
Type T
(0 to 400) °C
(0 to 500) °C
(-80 to 0) °C
(>0 to 200) °C
1.8 °C
1.8 °C
1.4 °C
1.6 °C
Fluke process
calibrator &
thermocouple
Temperature –
Chamber/Oven/Freezer/U
LTs
3
Bench-Top:
Type J
Type K
Type T
Reach-In:
Type J
Type K
Type T
Walk-In:
Type J
Type K
Type T
(0 to 400) °C
(0 to 500) °C
(-80 to 0) °C
(>0 to 200) °C
(0 to 400) °C
(0 to 500) °C
(-80 to 0) °C
(>0 to 200) °C
(0 to 400) °C
(0 to 500) °C
(-80 to 0) °C
(>0 to 200) °C
1.4 °C
1.0 °C
1.2 °C
1.2 °C
1.4 °C
1.2 °C
1.2 °C
1.2 °C
1.4 °C
1.2 °C
1.2 °C
1.2 °C
Fluke process
calibrator &
thermocouple
Humidity – Measure3
(0.4 to 35) %RH
(>35 to 80) %RH
(>80 to 96) %RH
0.98 % RH
0.0071H + 0.73 % RH
1.3 % RH
Rotronic HC2A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7066.01) 5/14/2025 Page 4 of 5
Parameter/Equipment
Range
CMC2, 6, 8 (±)
Comments
Humidity – Chamber3
Bench-Top
Reach-In
Walk-In
(0.4 to 35) %RH
(>35 to 80) %RH
(>80 to 96) %RH
(0.4 to 35) %RH
(>35 to 80) %RH
(>80 to 96) %RH
(0.4 to 35) %RH
(>35 to 80) %RH
(>80 to 96) %RH
0.98 % RH
0.0071H + 0.73 % RH
1.3 % RH
0.98 % RH
0.0071H + 0.73 % RH
1.3 % RH
0.97 % RH
0.0071H + 0.73 % RH
1.3 % RH
Rotronic HC2A
____________________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards of n early ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the
laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be
considered and this, on its own, could result in the actual measurement uncertainty achievable on a
customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 Field temperature measurements made outside environmental conditions between 18 °C to 28 °C (65 °F
to 82 °F), shall include additional an uncertainty of 0.05T where T is the difference in temperature outside
of 18 °C to 28 °C.
6 Field humidity measurements made outside environmental conditions between 10 °C to 30 °C (50 °F to
86 °F), shall include additional an uncertainty of +0.5 % RH between -10 °C to 50 °C, +2.5 % RH between
-50 °C to -30 °C, +1.5 % RH between -30 °C to -10 °C, and +1 % RH between 50 °C to 70 °C. Refer to
OEM specifications for additional temperature ranges.
7 Field measurements made with the Fluke Process Calibrator outside environmental conditions between
18 °C to 28 °C (65 °F to 82 °F), shall include additional an uncertainty of 0.005 %/°C. | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7066.01) 5/14/2025 Page 5 of 5
8 H is the value in % RH for range (>35 to 80) % RH.
9 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
10 This scope meets A2LA’s P112 Flexible Scope Policy. | 35 to 80 % RH |
| 6 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- JJ CalibrationsPortland, OR · ~56 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. MICHELLI CO., LLC - BEAVERTONBeaverton, OR · ~58 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Global Calibration ServicesTukwila, WA · ~168 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- ThermetricsSeattle, WA · ~182 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- SIMCO Electronics - SeattleRedmond, WA · ~193 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.