Registers refreshed 2026-11-20.See refresh dates
Italy

CHIMICA CASEARIA di Vighi Uber e Paolo

Via Marconi, 40, 46040, Gazoldo degli Ippoliti, Italy

Visit website
ACCREDIA 01477ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
10
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 10 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO 4832Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of coliforms - Colony-count technique
ISO 4833-1Microbiology of the food chain - Horizontal method for the enumeration of microorganisms - Part 1: Colony count at 30 °C by the pour plate technique
ISO 5764Milk - Determination of freezing point - Thermistor cryoscope method (Reference method)
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9622Milk and liquid milk products - Guidelines for the application of mid-infrared spectrometry
ISO 13366-2Milk - Enumeration of somatic cells - Part 2: Guidance on the operation of fluoro-opto-electronic counters
ISO 14675Milk and milk products - Guidelines for a standardized description of competitive enzyme immunoassays - Determination of aflatoxin M1 content
ISO 21528-2Microbiology of the food chain - Horizontal method for the detection and enumeration of Enterobacteriaceae - Part 2: Colony-count technique

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.

Scope as published by ACCREDIA

1 line
ACCREDIA

ISO/IEC 17025

Active

01477

View scope

Accredited scope, certificate 01477

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 9308-1:2017; UNI EN ISO 7899-2:2003; UNI EN ISO 6222:2001; ISO 4832:2006; UNI EN ISO 14675:2003; UNI EN ISO 13366-2:2007; MI-09 Rev.06/2021; UNI ISO 9622:2014; AFNOR DSM 28/02-02/12; UNI EN ISO 5764:2009; UNI EN ISO 21528-2:2017/EC 1:2018; AFNOR UNI 03/04-04/05; UNI EN ISO 4833-1:2022; AFNOR UNI 03/06-12/07Drinking water3000 to 6500000 UFC/ml

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via Marconi, 40, Gazoldo degli Ippoliti, 46040, IT

45.20028, 10.57938

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.