RTX (FL) Corporation dba Pratt & Whitney Calibration Services

17900 Beeline Highway, M/S 724-14, 33478, Jupiter, FL, United States

Visit website
A2LA 2322.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
17
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 2322.01 · 17 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540.1-1994-to 1100 V
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 2 of 16 Parameter/Equipment Range CMC2, 3, 4, 5 (±) Comments DC Current – Generate (0 to 220) µA >220 µA to 2.2 mA (>2.2 to 22) mA (>22 to 220) mA >220 mA to 2.2 A (>2.2 to 11) A 40 µA/A + 8 nA 35 µA/A + 28 nA 35 µA/A + 155 nA 45 µA/A + 2.5 µA 80 µA/A + 85 µA 360 µA/A + 500 µA Fluke 5730A/05 Fluke 5730A/05/5725A DC Current – Measure Up to 100 nA (>0.1 to 1) µA (>1 to 10) µA (>10 to 100) µA >100 µA to 1 mA (>1 to 10) mA (>10 to 100) mA >100 mA to 1.1 A 40 nA/A + 0.04 nA 27 µA/A + 0.04 nA 26 µA/A + 0.1 nA 26 µA/A + 0.8 nA 26 μA/A + 0.005 µA 26 μA/A + 0.05 μA 41 μA/A + 0.5 μA 115 µA/A + 11 µA HP 3458A option 002 Resistance – Generate Fixed Points 0 Ω 1 Ω, 1.9 Ω 10 Ω, 19 Ω 100 Ω, 190 Ω 1 kΩ, 1.9 kΩ 10 kΩ, 19 kΩ 100 kΩ, 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 0.001 Ω 0.01 Ω 0.1 Ω 1 Ω 10 Ω 25 Ω 100 Ω 400 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 100 MΩ 1 GΩ 40 µΩ 95 µΩ/Ω + 17 µΩ 23 µΩ/Ω + 46 µΩ 10 µΩ/Ω + 185 µΩ 6.5 µΩ/Ω + 2.4 mΩ 6.5 µΩ/Ω + 24 mΩ 8.5 µΩ/Ω + 0.47 Ω 13 µΩ/Ω + 2.7 Ω 18 µΩ/Ω + 3.1 Ω 48 µΩ/Ω 47 µΩ/Ω 100 µΩ/Ω 7.3 µΩ/Ω 2.2 µΩ/Ω 2.4 µΩ/Ω 3.3 µΩ/Ω 3.5 µΩ/Ω 1.6 µΩ/Ω 2.4 µΩ/Ω 3.3 µΩ/Ω 3.5 µΩ/Ω 0.9 µΩ/Ω 2.4 µΩ/Ω 4 µΩ/Ω 3.3 µΩ/Ω 2.6 µΩ/Ω 31 µΩ/Ω Fluke 5730A/05 L&N 4223B L&N 4222B L&N 4221B Fluke 742A-1 Fluke 742A-10 Fluke 742A-25 Fluke 742A-100 Meas. Int. 9331/400 Fluke 742A-1K Fluke 742A-10K Meas. Int. 9331/1M Meas. Int. 9331/1M Fluke 742A-10M Meas. Int. 9331/100M Fluke 8508-7000K
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 3 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments Resistance – Measure (0 to 10) Ω (>10 to 100) Ω >100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ >100 kΩ to 1MΩ (>1 to 10) MΩ (>10 to 100) MΩ 18 µΩ/Ω + 54 µΩ 15 µΩ/Ω + 0.7 mΩ 13 µΩ/Ω + 0.7 mΩ 13 µΩ/Ω + 7 mΩ 13 µΩ/Ω + 80 mΩ 18 µΩ/Ω + 2 Ω 53 µΩ/Ω + 170 Ω 500 µΩ/Ω + 1.1 kΩ HP 3458A option 002 Parameter/Range Frequency CMC2, 3 (±) Comments AC Current – Generate (0 to 220) µA >220 µA to 2.2 mA (>2.2 to 22) mA (>22 to 220) mA >220 mA to 2.2 A (>2.2 to 11) A (10 to 20) Hz (>20 to 40) Hz >40 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz (10 to 20) Hz (>20 to 40) Hz >40 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz (10 to 20) Hz (>20 to 40) Hz >40 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz (10 to 20) Hz (>20 to 40) Hz >40 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz 20 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz 40 Hz to 1 kHz (>1 to 5) kHz (>5 to 10) kHz 250 µA/A + 16 nA 160 µA/A + 10 nA 100 µA/A + 16 nA 280 µA/A + 40 nA 1100 µA/A + 80 nA 250 μA/A + 65 nA 160 μA/A + 78 nA 100 μA/A + 90 nA 200 μA/A + 190 nA 1100 μA/A + 680 nA 250 μA/A + 1 µA 180 μA/A + 0.67 µA 100 μA/A + 1 µA 200 μA/A + 1.4 µA 1100 μA/A + 5.3 µA 250 μA/A + 10.8 μA 160 μA/A + 7.9 μA 100 μA/A + 13 μA 200 μA/A + 11 μA 1100 μA/A + 232 μA 244 μA/A + 69 μA 450 μA/A + 130 μA 7000 μA/A + 710 μA 460 µA/A + 210 µA 950 µA/A + 400 µA 3600 µA/A + 760 µA Fluke 5730A/05 Fluke 5730A/05/5725A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 4 of 16 Parameter/Range Frequency CMC2, 3, 4, 5 (±) Comments AC Current – Measure (0.1 to 10) µA (>10 to 100) µA (>.1 to100) mA >100 mA to 1.05 A (1 to 30) kHz (10 to 20) Hz (>20 to 45) Hz >45 Hz to 5 kHz (10 to 20) Hz (>20 to 45) Hz (>45 Hz to 100) Hz >100 Hz to 5 kHz (>5 to 20) kHz (>20 to 50) kHz (10 to 20) Hz (>20 to 45) Hz (>45 to 100) Hz >100 Hz to 5 kHz (>5 to 20) kHz (>20 to 50) kHz 0.2 % + 0.03 % range 0.4 % + 0.03 % range 0.15 % + 0.07 % range 0.06 % + 0.03 % range 0.4 % + 0.02 % range 0.15 % + 0.02 % range 0.06 % + 0.02 % range 0.03 % + 0.03 % range 0.06 % + 0.09 % range 0.4 % + 0.18 % range 0.4 % + 0.02 % range 0.16 % + 0.02 % range 0.08 % + 0.02 % range 0.1 % + 0.03 % range 0.3 % + 0.07 % range 1.0 % + 0.05 % range Fluke 8588A HP 3458A option 002 AC Voltage – Generate (0 to 2.2) mV (>2.2 to 22) mV (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz >500 kHz to 1 MHz (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz >500 kHz to 1 MHz 240 µV/V + 4.1 µV 90µV/V + 5.1 µV 80 µV/V + 4.1 µV 200 µV/V + 4.1 µV 500 µV/V + 5.1 µV 1000 µV/V + 10 µV 1400 µV/V + 22 µV 2700 µV/V + 25 µV 240 µV/V + 4.2 µV 90µV/V + 5.1 µV 80 µV/V + 4.3 µV 200 µV/V + 4.2 µV 500 µV/V + 5.5 µV 1000 µV/V + 12 µV 1400 µV/V + 21 µV 2700 µV/V + 34 µV Fluke 5730A/05
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 5 of 16 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (cont) (>22 to 220) mV >220 mV to 2.2 V (>2.2 to 22) V (>22 to 220) V (0 to 1100) V Maximum output 250 V from (15 to 50) Hz. (0 to 750) V (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz >500 kHz to 1 MHz (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz >500 kHz to 1 MHz (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz >500 kHz to 1 MHz (10 to 20) Hz (>20 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz (>300 to 500) kHz >500 kHz to 1 MHz (15 to 50) Hz >50 Hz to 1 kHz (>1 to 20) kHz (>20 to 30) kHz (30 to 50) kHz (>50 to 100) kHz 240 µV/V + 13 µV 90 µV/V + 9 µV 57 µV/V + 7.5 µV 120 µV/V + 9.5 µV 310 µV/V + 18 µV 660 µV/V + 21 µV 1400 µV/V + 26 µV 2700 µV/V + 67 µV 240 µV/V + 45 µV 90 µV/V + 16 µV 42 µV/V + 10 µV 67 µV/V + 11 µV 85 µV/V + 31 µV 340 µV/V + 100 µV 1000 µV/V + 200 µV 1700 µV/V + 400 µV 240 µV/V + 550 µV 90 µV/V + 180 µV 42 µV/V + 150 µV 67 µV/V + 110 µV 83 µV/V + 210 µV 250 µV/V + 1300 µV 1000 µV/V + 2500 µV 1500 µV/V + 16 mV 240 µV/V + 4 mV 90 µV/V + 2.5 mV 52 µV/V + 2.3 mV 80 µV/V + 3.2 mV 150 µV/V + 3.3 mV 900 µV/V + 20 mV 4400 µV/V + 8.3 mV 150 µV/V + 240 mV 300 µV/V + 29 mV 70 µV/V + 21 mV 160 µV/V + 7 mV 600 µV/V + 12 mV 600 µV/V + 12 mV 2300 µV/V + 47 mV Fluke 5730A/05 Fluke 5730A/05/5725A
0 to 1100 V
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 6 of 16 Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Voltage – Measure Up to 10 mV >10 mV to 10 V (>10 to 100) V (>100 to 750) V (1 to 40) Hz >40 Hz to 1 kHz (>1 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz >300 kHz to 1 MHz (>1 to 4) MHz (>4 to 8) MHz (1 to 40) Hz >40 Hz to 1 kHz (>1 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz >300 kHz to 1 MHz (>1 to 2) MHz (>2 to 4) MHz (>4 to 8) MHz (>8 to 10) MHz (1 to 40) Hz >40 Hz to 20 kHz (>20 to 50) kHz (>50 to 100) kHz (>100 to 300) kHz >300 kHz to 1 MHz (1 to 40) Hz >40 Hz to 1 kHz (>1 to 20) kHz (>20 to 50) kHz (>50 to 100) kHz 0.03 % + 0.034 % range 0.02 % + 0.018 % range 0.03 % + 0.018 % range 0.1 % + 0.013 % range 0.5 % + 0.012 % range 4 % + 0.02 % range 1.2 % + 0.05 % range 7 % + 0.07 % range 20 % + 0.08 % range 0.007 % + 0.0048 % range 0.007 % + 0.0026 % range 0.014 % + 0.0023 % range 0.03 % + 0.0036 % range 0.08 % + 0.0026 % range 0.3 % + 0.01 % range 1 % + 0.01 % range 1.5 % + 0.01 % range 4 % + 0.07 % range 4 % + 0.08 % range 15 % + 0.1 % range 0.02 % + 0.004 % range 0.02 % + 0.003 % range 0.035 % + 0.004 % range 0.12 % + 0.004 % range 0.4 % + 0.01 % range 1.5 % + 0.01 % range 0.04 % + 0.004 % range 0.04 % + 0.002 % range 0.06 % + 0.002 % range 0.12 % + 0.002 % range 0.30 % + 0.002 % range HP 3458A opt 002
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 7 of 16 Parameter/Range Frequency CMC2, 3, 5 (±) Comments AC Voltage Flatness – Measure Up to 2.2 mV (>2.2 to 7) mV (>7 to 22) mV (10 to 30) Hz (>30 to 120) Hz >120 Hz to 1.2 kHz (>1.2 to 120) kHz (>120 to 500) kHz >500 kHz to 1.2 MHz (>1.2 to 2) MHz (>2 to 10) MHz (>10 to 20) MHz (>20 to 30) MHz (>30 to 50) MHz (10 to 30) Hz (>30 to 120) Hz >120 Hz to 1.2 kHz (>1.2 to 120) kHz (>120 to 500) kHz >500 kHz to 1.2 MHz (>1.2 to 2) MHz (>2 to 10) MHz (>10 to 20) MHz (>20 to 30) MHz (>30 to 50) MHz (10 to 30) Hz (>30 to 120) Hz >120 Hz to 1.2 kHz (>1.2 to 120) kHz (>120 to 500) kHz >500 kHz to 1.2 MHz (>1.2 to 2) MHz (>2 to 10) MHz (>10 to 20) MHz (>20 to 30) MHz (>30 to 50) MHz 0.15 % + 0.2µV 0.075 % + 0.1µV 0.075 % + 0.35µV 0.075 % + 0.25µV 0.11 % + 1.1µV 0.11 % + 1.1 µV 0.11 % + 1.2 µV 0.26 % + 1.2 µV 0.45 % + 1.2 µV 1 % + 10 µV 1 % + 3.0 µV 0.15 % + 1.2 µV 0.075 % + 0.2 µV 0.075 % + 0.1 µV 0.075 % + 0.3 µV 0.1 % + 1.3 µV 0.1 % + 1.6 µV 0.1 % + 1.8 µV 0.15 % + 2.2 µV 0.25 % + 2.2 µV 0.55 % + 2.8 µV 0.75 % + 4.9 µV 0.15 % + 0.5 µV 0.075 % + 0.3 µV 0.075 % + 0.2 µV 0.075 % + 1.1 µV 0.1 % + 1.0 µV 0.1 % + 1.5 µV 0.1 % + 2.5 µV 0.15 % + 6.0 µV 0.25 % + 6.5 µV 0.55 % + 7.0 µV 0.90 % + 10 µV Fluke 5790B/AF (referenced to 1 kHz)
to 2.2 mV
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 8 of 16 Parameter/Range Frequency CMC2, 3, 5 (±) Comments AC Voltage Flatness – Measure (cont) (>22 to 70) mV (>70 to 220) mV (>220 to 700) mV >700 mV to 2.2 V (10 to 30) Hz (>30 to 120) Hz >120 Hz to 1.2 kHz (>1.2 to 120) kHz (>120 to 500) kHz >500 kHz to 1.2 MHz (>1.2 to 2) MHz (>2 to 10) MHz (>10 to 20) MHz (>20 to 30) MHz (>30 to 50) MHz (10 to 30) Hz (>30 to 120) Hz >120 Hz to 1.2 kHz (>1.2 to 120) kHz (>120 to 500) kHz >500 kHz to 1.2 MHz (>1.2 to 2) MHz (>2 to 10) MHz (>10 to 20) MHz (>20 to 30) MHz (>30 to 50) MHz (10 to 30) Hz (>30 to 120) Hz >120 Hz to 1.2 kHz (>1.2 to 120) kHz (>120 to 500) kHz >500 kHz to 1.2 MHz (>1.2 to 2) MHz (>2 to 10) MHz (>10 to 20) MHz (>20 to 30) MHz (>30 to 50) MHz (10 to 30) Hz (>30 to 120) Hz (>120 Hz to 1.2 kHz (>1.2 to 120) kHz (>120 to 500) kHz >500 kHz to 1.2 MHz (>1.2 to 2) MHz (>2 to 10) MHz (>10 to 20) MHz (>20 to 30) MHz (>30 to 50) MHz 0.15 % + 1.2 µV 0.075 % + 1.0 µV 0.075 % + 1.0 µV 0.075 % + 1.1 µV 0.075 % + 1.3 µV 0.075 % + 1.8 µV 0.075 % + 1.8 µV 0.15 % + 3.5 µV 0.22 % + 6.5 µV 0.52 % + 12 µV 0.90 % + 21 µV 0.15 % + 3.1 µV 0.06 % + 1.6 µV 0.06 % + 1.6 µV 0.06 % + 4.1 µV 0.06 % + 4.2 µV 0.075 % + 5.1 µV 0.075 % + 6.4 µV 0.15 % + 10 µV 0.22 % + 20 µV 0.52 % + 31 µV 0.90 % + 56 µV 0.15 % + 3.1 µV 0.045 % + 2.3 µV 0.045 % + 2.5 µV 0.045 % + 8 µV 0.045 % + 10 µV 0.075 % + 13 µV 0.075 % + 10 µV 0.15 % + 12 µV 0.22 % + 46 µV 0.52 % + 44 µV 0.90 % + 90 µV 0.15 % + 30 µV 0.045 % + 14 µV 0.045 % + 13 µV 0.045 % + 37 µV 0.045 % + 47 µV 0.075 % + 40 µV 0.075 % + 43 µV 0.15 % + 65 µV 0.22 % + 170 µV 0.52 % + 290 µV 0.90 % + 570 µV Fluke 5790B/AF (referenced to 1 kHz)
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 9 of 16 Parameter/Range Frequency CMC2, 3, 5 (±) Comments AC Voltage Flatness – Measure (cont) (>2.2 to 7) V (10 to 30) Hz (>30 to 120) Hz >120 Hz to 1.2 kHz (>1.2 to 120) kHz (>120 to 500) kHz >500 kHz to 1.2 MHz (>1.2 to 2) MHz (>2 to 10) MHz (>10 to 20) MHz (>20 to 30) MHz (>30 to 50) MHz 0.15 % + 90 µV 0.045 % + 70 µV 0.045 % + 70 µV 0.045 % + 70 µV 0.045 % + 70 µV 0.075 % + 71 µV 0.075 % + 71 µV 0.15 % + 110 µV 0.22 % + 250 µV 0.52 % + 510 µV 0.90 % + 1 mV Fluke 5790B/AF (referenced to 1 kHz) AC Voltage Flatness – Generate 0.3 mV to 3.5 V (>0.3 to 1.1) mV (>1.1 to 3.3) mV >3.3 mV to 3.5 V (10 to 30) Hz >30 Hz to 119.99 kHz 120 kHz to 1.1999 MHz (1.2 to 2) MHz (2 to 11.9) MHz (12 to 20) MHz (20 to 30) MHz (30 to 50) MHz 120 kHz to 1.1999 MHz (1.2 to 2) MHz (2 to 11.9) MHz (12 to 20) MHz (>20 to 30) MHz (>30 to 50) MHz 120 kHz to 1.1999 MHz (1.2 to 2) MHZ (2 to 11.9) MHz (12 to 20) MHz (>20 to 30) MHz (>30 to 50) MHz 0.31 % 0.11 % 0.2 % + 3 µV 0.2 % + 3 µV 0.4 % + 4 µV 0.6 % + 5 µV 1.7 % + 16 µV 3.0 % + 16 µV 0.15 % + 4 µV 0.15 % + 5 µV 0.35 % + 5 µV 0.53 % + 6 µV 1.5 % + 7 µV 3.0 % + 7 µV 0.11 % + 3 µV 0.11 % + 3 µV 0.21 % + 3 µV 0.45 % + 3 µV 1.02 % + 3 µV 2 % + 3 µV Fluke 5730A/05, (referenced to 1 kHz)
10--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 10 of 16 Parameter/Range Frequency CMC2, 3, 5, 6 (±) Comments Oscilloscopes – Amplitude DC 50 Ω 1 MΩ Amplitude, Square wave (peak to peak) 50 Ω 1 MΩ Leveled Sine Wave Amplitude@ 50 kHz Flatness rel 50 kHz Time Marker Rise Time (0 to ± 6.6) V (0 to ± 130) V ± 1 mV to ± 6.6 V 1 mV to ± 130 V 50 kHz reference 50 kHz to 100 MHz (>100 to 300) MHz (>300 to 600) MHz 50 kHz to 100 MHz (>100 to 300) MHz (>300 to 600) MHz 5 s to 50 ms 20 ms to 2 ns 1 kHz to 2 MHz (200 to 300) ps (2 to 10) MHz (200 to 350) ps 0.25 % + 300 µV 0.05 % + 240 µV 0.25 % + 130 µV 0.1 % + 150 µV 2 % + 350 µV 3.5 % + 690 µV 4 % + 570 µV 6 % + 330 µV 1.5 % + 500 µV 2 % + 340 µV 4 % + 750 µV (25 + 1000t) parts in 10 2.5 parts in 10 180 ps 180 ps Fluke 5522A PQ/1G Fluke 5522A PQ/1G Phase Angle – Generate 0.5 V / 3 V (0 to 359.99) ° (0 to 359.99) ° (0 to 359.99) ° (0 to 359.99) ° (0 to 359.99) ° (0 to 359.99) ° (>10 to 65) Hz (>65 to 500) Hz (>500 to 1000) Hz (>1 to 5) kHz (>5 to 10) kHz (>10 to 30) kHz 0.08 ° 0.20 ° 0.38 ° 1.9 ° 3.8 ° 7.6 ° Fluke 5522A PQ/1G
0 to 359.99 °
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 11 of 16 Parameter/Equipment Range CMC2, 3, 5 (±) Comments Capacitance – Generate Fixed Points 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 120) Hz 1 µF 1nF 10nF 100pF 0.1pF to 1.2nF (1.2001 to 12) nF (12.0001 to 120) nF (0.120 001 to 1.2) µF (1.200 01 to 12) µF (12.0001 to 120) µF (0.120 001 to 1.2) mF (1.200 01 to 12) mF (12.0001 to 120) mF 0.014 % 0.0062 % 0.011 % 0.017 % 2.9pF + 1.3pF/nF 6pF + 1.4pF/nF 34pF + 1.5pF/nF 0.34nF + 1.6nF/µF 3.4nF + 1.6nF/µF 28nF + 1.7nF/µF 0.28µF + 2.8µF/mF 3.3µF + 2.7µF/mF 34µF + 5.3µF/mF IET Labs SCA-1uF IET Labs SCA-1nF IET Labs SCA-10nF IET Labs SCA-100pF Fluke 5560A Electrical RTD Simulation – Pt 385, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω (-210 to -80) °C (>-80 to 0) °C (>0 to 100) °C (>100 to 300) °C (>300 to 400) °C (>400 to 630) °C (>630 to 800) °C (-210 to -80) °C (>-80 to 0) °C (>0 to 100) °C (>100 to 300) °C (>300 to 400) °C (>400 to 630) °C (-200 to -190) °C (>-190 to -80) °C (>-80 to 0) °C (>0 to 100) °C (>100 to 260) °C (>260 to 300) °C (>300 to 400) °C (>400 to 600) °C (>600 to 630) °C 0.05 °C 0.05 °C 0.07 °C 0.09 °C 0.10 °C 0.12 °C 0.23 °C 0.05 °C 0.05 °C 0.07 °C 0.09 °C 0.10 °C 0.12 °C 0.25 °C 0.04 °C 0.05 °C 0.06 °C 0.07 °C 0.08 °C 0.09 °C 0.10 °C 0.23 °C Fluke 5522A
to 120 mF
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 12 of 16 Parameter/Equipment Range CMC2, 3, 5 (±) Comments Electrical RTD Simulation (cont) – Pt 385, 200 Ω Pt 385, 500 Ω Pt 385, 1000 Ω Pt 385, 1000 Ω PtNi 385, 120 Ω (Ni 120) Cu 427, 10 Ω (-200 to -80) °C (>-80 to 0) °C (>0 to 100) °C (>100 to 260) °C (>260 to 300) °C (>300 to 400) °C (>400 to 600) °C (>600 to 630) °C (-200 to -80) °C (>-80 to 0) °C (>0 to 100) °C (>100 to 260) °C (>260 to 300) °C (>300 to 400) °C (>400 to 600) °C (>600 to 630) °C (-200 to -80) °C (>-80 to 0) °C (>0 to 100) °C (>100 to 260) °C (>260 to 300) °C (>300 to 400) °C (>400 to 600) °C (>600 to 630) °C (-80 to 0) °C (>0 to 100) °C (>100 to 260) °C (-100 to 260) °C 0.04 °C 0.04 °C 0.04 °C 0.05 °C 0.12 °C 0.13 °C 0.14 °C 0.16 °C 0.04 °C 0.05 °C 0.05 °C 0.06 °C 0.08 °C 0.08 °C 0.09 °C 0.11 °C 0.03 °C 0.03 °C 0.04 °C 0.05 °C 0.06 °C 0.07 °C 0.07 °C 0.23 °C 0.08 °C 0.08 °C 0.14 °C 0.03 °C Fluke 5522A
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 13 of 16 III. Fluid Quantities Parameter/Equipment Range CMC2, 5 (±) Comments Flow – Gas Measuring Equipment (3 to 30) slm (>30 to 100) slm (100 to 1000) slm (0.005 to 0.5) lb/sec 0.12 % + 0.024 slm 0.12 % + 0.11 slm 0.12 % + 0.3 slm 0.5 % DH Molbox-1 (Gn2, He, Arg) Molbloc-S prem CFV calibration process (GN2, He) IV. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Force – Measuring Equipment Up to 1000 lbf (>1000 to 5000) lbf (>5000 to 10 000) lbf (>10 000 to 25 000) lbf (>25 000 to 50 000) lbf (>50 000 to 100 000) lbf 3.1E-3 % full scale 4.6E-03 % full scale 0.036 % full scale 0.037 % full scale 0.023 % full scale 0.04 % full scale Morehouse 1K dead weight machine Pratt & Whitney 5K dead weight machine Loadcell to loadcell comparison Mass 1 mg to 5 g (5 to 520) g (453 to 22 679) g (>22 679 to 45 358) g (>45 358 to 63 501) g 0.036 mg + 7.92 ng/mg 0.11 mg + 0.93 µg/g 35 mg + 3.2 µg/g 54 mg + 2.4 µg/g 0.16g Mettler Toledo XPE505C, mass pieces Mettler Toledo XPR64002LC, mass pieces Pneumatic Absolute Pressure (1.01 to 55.1) psi (5.08 to 277) psi (20.3 to 1110) psi 0.0013 % + 2.9E-5 psi 0.0015 % + 7.3E-05 psi 0.0020 % + 2.9E-04 psi Fluke PG7601, N2 as gas medium
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 14 of 16 Parameter/Equipment Range CMC2, 5 (±) Comments Pressure, (ADWT/ODWT) (58 to 15 954) psi (gas) (29 to 7977) psi (oil) (145 to 39 885) psi (oil) 0.0048 % + .004 psi 0.0027 % + .0029 psi 0.0046 % + .015 psi Fluke 7202 ADWT/ODWT Vibration General Purpose – Acceleration Sensitivity Magnitude (Up to 100 mV/gn Up to 10 pC/gn) (5 to 9) Hz (10 to 99) Hz 100 Hz (101 to 920) Hz (921 to 5000) Hz (5001 to 10 000) Hz (10 to 15) kHz 2.3 % 1.7 % 1.3 % 1.4 % 1.7 % 2.2 % 2.8 % Reference accelerometer, back-to- back comparison method with Modal Shop TMS 9155C Vibration Cal System. Data acquisition card w/ 396C10/C11 air bearing shaker Force – Measuring Equipment Up to 1000 lbf (>1000 to 5000) lbf (>5000 to 10 000) lbf (>10 000 to 25 000) lbf (>25 000 to 50 000) lbf (>50 000 to 100 000) lbf 3.1E-3 % full scale 4.6E-03 % full scale 0.036 % full scale 0.037 % full scale 0.023 % full scale 0.04 % full scale Morehouse 1K dead weight machine Pratt & Whitney 5K dead weight machine Loadcell to loadcell Comparison Mass 1 mg to 5 g (5 to 520) g (453 to 22 679) g (>22 679 to 45 358) g (>45 358 to 63 501) g 0.036 mg + 7.9 ng/mg 0.11 mg + 0.93 µg/g 35 mg + 3.2 µg/g 54 mg + 2.3 µg/g 0.16 g Mettler Toledo XPE505C, mass pieces Mettler Toledo XPR64002LC, mass pieces
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 15 of 16 IV. Thermodynamic Parameter/Range Frequency CMC2 (±) Comments Temperature – Measure 0.01 °C (-197 to 0) °C (>0.01-230) °C (>230-400) °C (>400-660) °C (660 to 1450) °C 0.009 °C 0.012 °C 0.019 °C 0.022 °C 0.026 °C 2.4 °C Comparison with SPRT/triple point Comparison to SPRT Comparison with type S thermocouple Relative Humidity (10 to 90) % RH @ (-10 to 70) °C 0.7 % RH Thunder Scientific 2500-LT V. Time & Frequency Parameter/Range Frequency CMC2 (±) Comments Frequency – Measuring Equipment 10 MHz 1.5 part in 1013 Hz/ Hz Fluke 910R Frequency – Measure 1 mHz to 500 MHz 1 part in 1000 Hz/ Hz + 10µHz HP 5345A ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The measurands stated are generated with the Fluke 5730, 5790B and 5520 series of instruments . This capability is suitable for the calibration of the devices intended to measure the stated measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification.
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2322.01) 02/07/2025 Page 16 of 16 4 The measurands stated are measured with the HP 3458A. This capability is suitable for the calibration of the devices intended to generate the measurand in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a combination of the fraction of the reading/output plus a range specification. 5 In the statement of CMC the percentages are percentages of reading, unless otherwise noted. 6 In the statement of CMC t represents time in seconds.
17ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.