RTX (FL) Corporation dba Pratt & Whitney Calibration Services
17900 Beeline Highway, M/S 724-14, 33478, Jupiter, FL, United States
Visit website- Scope lines
- 17
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 17 scope lines.
A2LA certificate 2322.01 · 17 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540.1-1994 | - | to 1100 V |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 2 of 16
Parameter/Equipment
Range
CMC2, 3, 4, 5 (±)
Comments
DC Current – Generate
(0 to 220) µA
>220 µA to 2.2 mA
(>2.2 to 22) mA
(>22 to 220) mA
>220 mA to 2.2 A
(>2.2 to 11) A
40 µA/A + 8 nA
35 µA/A + 28 nA
35 µA/A + 155 nA
45 µA/A + 2.5 µA
80 µA/A + 85 µA
360 µA/A + 500 µA
Fluke 5730A/05
Fluke 5730A/05/5725A
DC Current – Measure
Up to 100 nA
(>0.1 to 1) µA
(>1 to 10) µA
(>10 to 100) µA
>100 µA to 1 mA
(>1 to 10) mA
(>10 to 100) mA
>100 mA to 1.1 A
40 nA/A + 0.04 nA
27 µA/A + 0.04 nA
26 µA/A + 0.1 nA
26 µA/A + 0.8 nA
26 μA/A + 0.005 µA
26 μA/A + 0.05 μA
41 μA/A + 0.5 μA
115 µA/A + 11 µA
HP 3458A option 002
Resistance – Generate
Fixed Points
0 Ω
1 Ω, 1.9 Ω
10 Ω, 19 Ω
100 Ω, 190 Ω
1 kΩ, 1.9 kΩ
10 kΩ, 19 kΩ
100 kΩ, 190 kΩ
1 MΩ
1.9 MΩ
10 MΩ
19 MΩ
100 MΩ
0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
25 Ω
100 Ω
400 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
40 µΩ
95 µΩ/Ω + 17 µΩ
23 µΩ/Ω + 46 µΩ
10 µΩ/Ω + 185 µΩ
6.5 µΩ/Ω + 2.4 mΩ
6.5 µΩ/Ω + 24 mΩ
8.5 µΩ/Ω + 0.47 Ω
13 µΩ/Ω + 2.7 Ω
18 µΩ/Ω + 3.1 Ω
48 µΩ/Ω
47 µΩ/Ω
100 µΩ/Ω
7.3 µΩ/Ω
2.2 µΩ/Ω
2.4 µΩ/Ω
3.3 µΩ/Ω
3.5 µΩ/Ω
1.6 µΩ/Ω
2.4 µΩ/Ω
3.3 µΩ/Ω
3.5 µΩ/Ω
0.9 µΩ/Ω
2.4 µΩ/Ω
4 µΩ/Ω
3.3 µΩ/Ω
2.6 µΩ/Ω
31 µΩ/Ω
Fluke 5730A/05
L&N 4223B
L&N 4222B
L&N 4221B
Fluke 742A-1
Fluke 742A-10
Fluke 742A-25
Fluke 742A-100
Meas. Int. 9331/400
Fluke 742A-1K
Fluke 742A-10K
Meas. Int. 9331/1M
Meas. Int. 9331/1M
Fluke 742A-10M
Meas. Int. 9331/100M
Fluke 8508-7000K | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 3 of 16
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance – Measure
(0 to 10) Ω
(>10 to 100) Ω
>100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
>100 kΩ to 1MΩ
(>1 to 10) MΩ
(>10 to 100) MΩ
18 µΩ/Ω + 54 µΩ
15 µΩ/Ω + 0.7 mΩ
13 µΩ/Ω + 0.7 mΩ
13 µΩ/Ω + 7 mΩ
13 µΩ/Ω + 80 mΩ
18 µΩ/Ω + 2 Ω
53 µΩ/Ω + 170 Ω
500 µΩ/Ω + 1.1 kΩ
HP 3458A option
002
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Current – Generate
(0 to 220) µA
>220 µA to 2.2 mA
(>2.2 to 22) mA
(>22 to 220) mA
>220 mA to 2.2 A
(>2.2 to 11) A
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
20 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
40 Hz to 1 kHz
(>1 to 5) kHz
(>5 to 10) kHz
250 µA/A + 16 nA
160 µA/A + 10 nA
100 µA/A + 16 nA
280 µA/A + 40 nA
1100 µA/A + 80 nA
250 μA/A + 65 nA
160 μA/A + 78 nA
100 μA/A + 90 nA
200 μA/A + 190 nA
1100 μA/A + 680 nA
250 μA/A + 1 µA
180 μA/A + 0.67 µA
100 μA/A + 1 µA
200 μA/A + 1.4 µA
1100 μA/A + 5.3 µA
250 μA/A + 10.8 μA
160 μA/A + 7.9 μA
100 μA/A + 13 μA
200 μA/A + 11 μA
1100 μA/A + 232 μA
244 μA/A + 69 μA
450 μA/A + 130 μA
7000 μA/A + 710 μA
460 µA/A + 210 µA
950 µA/A + 400 µA
3600 µA/A + 760 µA
Fluke 5730A/05
Fluke
5730A/05/5725A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 4 of 16
Parameter/Range
Frequency
CMC2, 3, 4, 5 (±)
Comments
AC Current – Measure
(0.1 to 10) µA
(>10 to 100) µA
(>.1 to100) mA
>100 mA to 1.05 A
(1 to 30) kHz
(10 to 20) Hz
(>20 to 45) Hz
>45 Hz to 5 kHz
(10 to 20) Hz
(>20 to 45) Hz
(>45 Hz to 100) Hz
>100 Hz to 5 kHz
(>5 to 20) kHz
(>20 to 50) kHz
(10 to 20) Hz
(>20 to 45) Hz
(>45 to 100) Hz
>100 Hz to 5 kHz
(>5 to 20) kHz
(>20 to 50) kHz
0.2 % + 0.03 % range
0.4 % + 0.03 % range
0.15 % + 0.07 % range
0.06 % + 0.03 % range
0.4 % + 0.02 % range
0.15 % + 0.02 % range
0.06 % + 0.02 % range
0.03 % + 0.03 % range
0.06 % + 0.09 % range
0.4 % + 0.18 % range
0.4 % + 0.02 % range
0.16 % + 0.02 % range
0.08 % + 0.02 % range
0.1 % + 0.03 % range
0.3 % + 0.07 % range
1.0 % + 0.05 % range
Fluke 8588A
HP 3458A option
002
AC Voltage – Generate
(0 to 2.2) mV
(>2.2 to 22) mV
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
>500 kHz to 1 MHz
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
>500 kHz to 1 MHz
240 µV/V + 4.1 µV
90µV/V + 5.1 µV
80 µV/V + 4.1 µV
200 µV/V + 4.1 µV
500 µV/V + 5.1 µV
1000 µV/V + 10 µV
1400 µV/V + 22 µV
2700 µV/V + 25 µV
240 µV/V + 4.2 µV
90µV/V + 5.1 µV
80 µV/V + 4.3 µV
200 µV/V + 4.2 µV
500 µV/V + 5.5 µV
1000 µV/V + 12 µV
1400 µV/V + 21 µV
2700 µV/V + 34 µV
Fluke 5730A/05 | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 5 of 16
Parameter/Range
Frequency
CMC2, 3 (±)
Comments
AC Voltage – Generate
(cont)
(>22 to 220) mV
>220 mV to 2.2 V
(>2.2 to 22) V
(>22 to 220) V
(0 to 1100) V
Maximum output 250
V from (15 to 50) Hz.
(0 to 750) V
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
>500 kHz to 1 MHz
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
>500 kHz to 1 MHz
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
>500 kHz to 1 MHz
(10 to 20) Hz
(>20 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
(>300 to 500) kHz
>500 kHz to 1 MHz
(15 to 50) Hz
>50 Hz to 1 kHz
(>1 to 20) kHz
(>20 to 30) kHz
(30 to 50) kHz
(>50 to 100) kHz
240 µV/V + 13 µV
90 µV/V + 9 µV
57 µV/V + 7.5 µV
120 µV/V + 9.5 µV
310 µV/V + 18 µV
660 µV/V + 21 µV
1400 µV/V + 26 µV
2700 µV/V + 67 µV
240 µV/V + 45 µV
90 µV/V + 16 µV
42 µV/V + 10 µV
67 µV/V + 11 µV
85 µV/V + 31 µV
340 µV/V + 100 µV
1000 µV/V + 200 µV
1700 µV/V + 400 µV
240 µV/V + 550 µV
90 µV/V + 180 µV
42 µV/V + 150 µV
67 µV/V + 110 µV
83 µV/V + 210 µV
250 µV/V + 1300 µV
1000 µV/V + 2500 µV
1500 µV/V + 16 mV
240 µV/V + 4 mV
90 µV/V + 2.5 mV
52 µV/V + 2.3 mV
80 µV/V + 3.2 mV
150 µV/V + 3.3 mV
900 µV/V + 20 mV
4400 µV/V + 8.3 mV
150 µV/V + 240 mV
300 µV/V + 29 mV
70 µV/V + 21 mV
160 µV/V + 7 mV
600 µV/V + 12 mV
600 µV/V + 12 mV
2300 µV/V + 47 mV
Fluke 5730A/05
Fluke 5730A/05/5725A | 0 to 1100 V |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 6 of 16
Parameter/Range
Frequency
CMC2, 4, 5 (±)
Comments
AC Voltage –
Measure
Up to 10 mV
>10 mV to 10 V
(>10 to 100) V
(>100 to 750) V
(1 to 40) Hz
>40 Hz to 1 kHz
(>1 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
(>1 to 4) MHz
(>4 to 8) MHz
(1 to 40) Hz
>40 Hz to 1 kHz
(>1 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
(>1 to 2) MHz
(>2 to 4) MHz
(>4 to 8) MHz
(>8 to 10) MHz
(1 to 40) Hz
>40 Hz to 20 kHz
(>20 to 50) kHz
(>50 to 100) kHz
(>100 to 300) kHz
>300 kHz to 1 MHz
(1 to 40) Hz
>40 Hz to 1 kHz
(>1 to 20) kHz
(>20 to 50) kHz
(>50 to 100) kHz
0.03 % + 0.034 % range
0.02 % + 0.018 % range
0.03 % + 0.018 % range
0.1 % + 0.013 % range
0.5 % + 0.012 % range
4 % + 0.02 % range
1.2 % + 0.05 % range
7 % + 0.07 % range
20 % + 0.08 % range
0.007 % + 0.0048 % range
0.007 % + 0.0026 % range
0.014 % + 0.0023 % range
0.03 % + 0.0036 % range
0.08 % + 0.0026 % range
0.3 % + 0.01 % range
1 % + 0.01 % range
1.5 % + 0.01 % range
4 % + 0.07 % range
4 % + 0.08 % range
15 % + 0.1 % range
0.02 % + 0.004 % range
0.02 % + 0.003 % range
0.035 % + 0.004 % range
0.12 % + 0.004 % range
0.4 % + 0.01 % range
1.5 % + 0.01 % range
0.04 % + 0.004 % range
0.04 % + 0.002 % range
0.06 % + 0.002 % range
0.12 % + 0.002 % range
0.30 % + 0.002 % range
HP 3458A
opt 002 | ||
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 7 of 16
Parameter/Range
Frequency
CMC2, 3, 5 (±)
Comments
AC Voltage Flatness –
Measure
Up to 2.2 mV
(>2.2 to 7) mV
(>7 to 22) mV
(10 to 30) Hz
(>30 to 120) Hz
>120 Hz to 1.2 kHz
(>1.2 to 120) kHz
(>120 to 500) kHz
>500 kHz to 1.2 MHz
(>1.2 to 2) MHz
(>2 to 10) MHz
(>10 to 20) MHz
(>20 to 30) MHz
(>30 to 50) MHz
(10 to 30) Hz
(>30 to 120) Hz
>120 Hz to 1.2 kHz
(>1.2 to 120) kHz
(>120 to 500) kHz
>500 kHz to 1.2 MHz
(>1.2 to 2) MHz
(>2 to 10) MHz
(>10 to 20) MHz
(>20 to 30) MHz
(>30 to 50) MHz
(10 to 30) Hz
(>30 to 120) Hz
>120 Hz to 1.2 kHz
(>1.2 to 120) kHz
(>120 to 500) kHz
>500 kHz to 1.2 MHz
(>1.2 to 2) MHz
(>2 to 10) MHz
(>10 to 20) MHz
(>20 to 30) MHz
(>30 to 50) MHz
0.15 % + 0.2µV
0.075 % + 0.1µV
0.075 % + 0.35µV
0.075 % + 0.25µV
0.11 % + 1.1µV
0.11 % + 1.1 µV
0.11 % + 1.2 µV
0.26 % + 1.2 µV
0.45 % + 1.2 µV
1 % + 10 µV
1 % + 3.0 µV
0.15 % + 1.2 µV
0.075 % + 0.2 µV
0.075 % + 0.1 µV
0.075 % + 0.3 µV
0.1 % + 1.3 µV
0.1 % + 1.6 µV
0.1 % + 1.8 µV
0.15 % + 2.2 µV
0.25 % + 2.2 µV
0.55 % + 2.8 µV
0.75 % + 4.9 µV
0.15 % + 0.5 µV
0.075 % + 0.3 µV
0.075 % + 0.2 µV
0.075 % + 1.1 µV
0.1 % + 1.0 µV
0.1 % + 1.5 µV
0.1 % + 2.5 µV
0.15 % + 6.0 µV
0.25 % + 6.5 µV
0.55 % + 7.0 µV
0.90 % + 10 µV
Fluke 5790B/AF
(referenced to 1 kHz) | to 2.2 mV |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 8 of 16
Parameter/Range
Frequency
CMC2, 3, 5 (±)
Comments
AC Voltage Flatness –
Measure (cont)
(>22 to 70) mV
(>70 to 220) mV
(>220 to 700) mV
>700 mV to 2.2 V
(10 to 30) Hz
(>30 to 120) Hz
>120 Hz to 1.2 kHz
(>1.2 to 120) kHz
(>120 to 500) kHz
>500 kHz to 1.2 MHz
(>1.2 to 2) MHz
(>2 to 10) MHz
(>10 to 20) MHz
(>20 to 30) MHz
(>30 to 50) MHz
(10 to 30) Hz
(>30 to 120) Hz
>120 Hz to 1.2 kHz
(>1.2 to 120) kHz
(>120 to 500) kHz
>500 kHz to 1.2 MHz
(>1.2 to 2) MHz
(>2 to 10) MHz
(>10 to 20) MHz
(>20 to 30) MHz
(>30 to 50) MHz
(10 to 30) Hz
(>30 to 120) Hz
>120 Hz to 1.2 kHz
(>1.2 to 120) kHz
(>120 to 500) kHz
>500 kHz to 1.2 MHz
(>1.2 to 2) MHz
(>2 to 10) MHz
(>10 to 20) MHz
(>20 to 30) MHz
(>30 to 50) MHz
(10 to 30) Hz
(>30 to 120) Hz
(>120 Hz to 1.2 kHz
(>1.2 to 120) kHz
(>120 to 500) kHz
>500 kHz to 1.2 MHz
(>1.2 to 2) MHz
(>2 to 10) MHz
(>10 to 20) MHz
(>20 to 30) MHz
(>30 to 50) MHz
0.15 % + 1.2 µV
0.075 % + 1.0 µV
0.075 % + 1.0 µV
0.075 % + 1.1 µV
0.075 % + 1.3 µV
0.075 % + 1.8 µV
0.075 % + 1.8 µV
0.15 % + 3.5 µV
0.22 % + 6.5 µV
0.52 % + 12 µV
0.90 % + 21 µV
0.15 % + 3.1 µV
0.06 % + 1.6 µV
0.06 % + 1.6 µV
0.06 % + 4.1 µV
0.06 % + 4.2 µV
0.075 % + 5.1 µV
0.075 % + 6.4 µV
0.15 % + 10 µV
0.22 % + 20 µV
0.52 % + 31 µV
0.90 % + 56 µV
0.15 % + 3.1 µV
0.045 % + 2.3 µV
0.045 % + 2.5 µV
0.045 % + 8 µV
0.045 % + 10 µV
0.075 % + 13 µV
0.075 % + 10 µV
0.15 % + 12 µV
0.22 % + 46 µV
0.52 % + 44 µV
0.90 % + 90 µV
0.15 % + 30 µV
0.045 % + 14 µV
0.045 % + 13 µV
0.045 % + 37 µV
0.045 % + 47 µV
0.075 % + 40 µV
0.075 % + 43 µV
0.15 % + 65 µV
0.22 % + 170 µV
0.52 % + 290 µV
0.90 % + 570 µV
Fluke 5790B/AF
(referenced to 1 kHz) | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 9 of 16
Parameter/Range
Frequency
CMC2, 3, 5 (±)
Comments
AC Voltage Flatness –
Measure (cont)
(>2.2 to 7) V
(10 to 30) Hz
(>30 to 120) Hz
>120 Hz to 1.2 kHz
(>1.2 to 120) kHz
(>120 to 500) kHz
>500 kHz to 1.2 MHz
(>1.2 to 2) MHz
(>2 to 10) MHz
(>10 to 20) MHz
(>20 to 30) MHz
(>30 to 50) MHz
0.15 % + 90 µV
0.045 % + 70 µV
0.045 % + 70 µV
0.045 % + 70 µV
0.045 % + 70 µV
0.075 % + 71 µV
0.075 % + 71 µV
0.15 % + 110 µV
0.22 % + 250 µV
0.52 % + 510 µV
0.90 % + 1 mV
Fluke 5790B/AF
(referenced to 1 kHz)
AC Voltage Flatness –
Generate
0.3 mV to 3.5 V
(>0.3 to 1.1) mV
(>1.1 to 3.3) mV
>3.3 mV to 3.5 V
(10 to 30) Hz
>30 Hz to 119.99 kHz
120 kHz to 1.1999 MHz
(1.2 to 2) MHz
(2 to 11.9) MHz
(12 to 20) MHz
(20 to 30) MHz
(30 to 50) MHz
120 kHz to 1.1999 MHz
(1.2 to 2) MHz
(2 to 11.9) MHz
(12 to 20) MHz
(>20 to 30) MHz
(>30 to 50) MHz
120 kHz to 1.1999 MHz
(1.2 to 2) MHZ
(2 to 11.9) MHz
(12 to 20) MHz
(>20 to 30) MHz
(>30 to 50) MHz
0.31 %
0.11 %
0.2 % + 3 µV
0.2 % + 3 µV
0.4 % + 4 µV
0.6 % + 5 µV
1.7 % + 16 µV
3.0 % + 16 µV
0.15 % + 4 µV
0.15 % + 5 µV
0.35 % + 5 µV
0.53 % + 6 µV
1.5 % + 7 µV
3.0 % + 7 µV
0.11 % + 3 µV
0.11 % + 3 µV
0.21 % + 3 µV
0.45 % + 3 µV
1.02 % + 3 µV
2 % + 3 µV
Fluke 5730A/05,
(referenced to 1 kHz) | ||
| 10 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 10 of 16
Parameter/Range
Frequency
CMC2, 3, 5, 6 (±)
Comments
Oscilloscopes –
Amplitude DC
50 Ω
1 MΩ
Amplitude, Square
wave (peak to peak)
50 Ω
1 MΩ
Leveled Sine Wave
Amplitude@ 50 kHz
Flatness rel 50 kHz
Time Marker
Rise Time
(0 to ± 6.6) V
(0 to ± 130) V
± 1 mV to ± 6.6 V
1 mV to ± 130 V
50 kHz reference
50 kHz to 100 MHz
(>100 to 300) MHz
(>300 to 600) MHz
50 kHz to 100 MHz
(>100 to 300) MHz
(>300 to 600) MHz
5 s to 50 ms
20 ms to 2 ns
1 kHz to 2 MHz
(200 to 300) ps
(2 to 10) MHz
(200 to 350) ps
0.25 % + 300 µV
0.05 % + 240 µV
0.25 % + 130 µV
0.1 % + 150 µV
2 % + 350 µV
3.5 % + 690 µV
4 % + 570 µV
6 % + 330 µV
1.5 % + 500 µV
2 % + 340 µV
4 % + 750 µV
(25 + 1000t) parts in 10
2.5 parts in 10
180 ps
180 ps
Fluke 5522A PQ/1G
Fluke 5522A PQ/1G
Phase Angle – Generate
0.5 V / 3 V
(0 to 359.99) °
(0 to 359.99) °
(0 to 359.99) °
(0 to 359.99) °
(0 to 359.99) °
(0 to 359.99) °
(>10 to 65) Hz
(>65 to 500) Hz
(>500 to 1000) Hz
(>1 to 5) kHz
(>5 to 10) kHz
(>10 to 30) kHz
0.08 °
0.20 °
0.38 °
1.9 °
3.8 °
7.6 °
Fluke 5522A PQ/1G | 0 to 359.99 ° |
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 11 of 16
Parameter/Equipment
Range
CMC2, 3, 5 (±)
Comments
Capacitance –
Generate
Fixed Points
10 Hz to 10 kHz
10 Hz to 3 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 120) Hz
1 µF
1nF
10nF
100pF
0.1pF to 1.2nF
(1.2001 to 12) nF
(12.0001 to 120) nF
(0.120 001 to 1.2) µF
(1.200 01 to 12) µF
(12.0001 to 120) µF
(0.120 001 to 1.2) mF
(1.200 01 to 12) mF
(12.0001 to 120) mF
0.014 %
0.0062 %
0.011 %
0.017 %
2.9pF + 1.3pF/nF
6pF + 1.4pF/nF
34pF + 1.5pF/nF
0.34nF + 1.6nF/µF
3.4nF + 1.6nF/µF
28nF + 1.7nF/µF
0.28µF + 2.8µF/mF
3.3µF + 2.7µF/mF
34µF + 5.3µF/mF
IET Labs SCA-1uF
IET Labs SCA-1nF
IET Labs SCA-10nF
IET Labs SCA-100pF
Fluke 5560A
Electrical RTD
Simulation –
Pt 385, 100 Ω
Pt 3926, 100 Ω
Pt 3916, 100 Ω
(-210 to -80) °C
(>-80 to 0) °C
(>0 to 100) °C
(>100 to 300) °C
(>300 to 400) °C
(>400 to 630) °C
(>630 to 800) °C
(-210 to -80) °C
(>-80 to 0) °C
(>0 to 100) °C
(>100 to 300) °C
(>300 to 400) °C
(>400 to 630) °C
(-200 to -190) °C
(>-190 to -80) °C
(>-80 to 0) °C
(>0 to 100) °C
(>100 to 260) °C
(>260 to 300) °C
(>300 to 400) °C
(>400 to 600) °C
(>600 to 630) °C
0.05 °C
0.05 °C
0.07 °C
0.09 °C
0.10 °C
0.12 °C
0.23 °C
0.05 °C
0.05 °C
0.07 °C
0.09 °C
0.10 °C
0.12 °C
0.25 °C
0.04 °C
0.05 °C
0.06 °C
0.07 °C
0.08 °C
0.09 °C
0.10 °C
0.23 °C
Fluke 5522A | to 120 mF |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 12 of 16
Parameter/Equipment
Range
CMC2, 3, 5 (±)
Comments
Electrical RTD
Simulation (cont) –
Pt 385, 200 Ω
Pt 385, 500 Ω
Pt 385, 1000 Ω
Pt 385, 1000 Ω
PtNi 385, 120 Ω
(Ni 120)
Cu 427, 10 Ω
(-200 to -80) °C
(>-80 to 0) °C
(>0 to 100) °C
(>100 to 260) °C
(>260 to 300) °C
(>300 to 400) °C
(>400 to 600) °C
(>600 to 630) °C
(-200 to -80) °C
(>-80 to 0) °C
(>0 to 100) °C
(>100 to 260) °C
(>260 to 300) °C
(>300 to 400) °C
(>400 to 600) °C
(>600 to 630) °C
(-200 to -80) °C
(>-80 to 0) °C
(>0 to 100) °C
(>100 to 260) °C
(>260 to 300) °C
(>300 to 400) °C
(>400 to 600) °C
(>600 to 630) °C
(-80 to 0) °C
(>0 to 100) °C
(>100 to 260) °C
(-100 to 260) °C
0.04 °C
0.04 °C
0.04 °C
0.05 °C
0.12 °C
0.13 °C
0.14 °C
0.16 °C
0.04 °C
0.05 °C
0.05 °C
0.06 °C
0.08 °C
0.08 °C
0.09 °C
0.11 °C
0.03 °C
0.03 °C
0.04 °C
0.05 °C
0.06 °C
0.07 °C
0.07 °C
0.23 °C
0.08 °C
0.08 °C
0.14 °C
0.03 °C
Fluke 5522A | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 13 of 16
III. Fluid Quantities
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Flow – Gas
Measuring Equipment
(3 to 30) slm
(>30 to 100) slm
(100 to 1000) slm
(0.005 to 0.5) lb/sec
0.12 % + 0.024 slm
0.12 % + 0.11 slm
0.12 % + 0.3 slm
0.5 %
DH Molbox-1
(Gn2, He, Arg)
Molbloc-S prem
CFV calibration
process (GN2, He)
IV. Mechanical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Force – Measuring
Equipment
Up to 1000 lbf
(>1000 to 5000) lbf
(>5000 to 10 000) lbf
(>10 000 to 25 000) lbf
(>25 000 to 50 000) lbf
(>50 000 to 100 000) lbf
3.1E-3 % full scale
4.6E-03 % full scale
0.036 % full scale
0.037 % full scale
0.023 % full scale
0.04 % full scale
Morehouse 1K dead
weight machine
Pratt & Whitney 5K
dead weight
machine
Loadcell to loadcell
comparison
Mass
1 mg to 5 g
(5 to 520) g
(453 to 22 679) g
(>22 679 to 45 358) g
(>45 358 to 63 501) g
0.036 mg + 7.92 ng/mg
0.11 mg + 0.93 µg/g
35 mg + 3.2 µg/g
54 mg + 2.4 µg/g
0.16g
Mettler Toledo
XPE505C, mass
pieces
Mettler Toledo
XPR64002LC, mass
pieces
Pneumatic Absolute
Pressure
(1.01 to 55.1) psi
(5.08 to 277) psi
(20.3 to 1110) psi
0.0013 % + 2.9E-5 psi
0.0015 % + 7.3E-05 psi
0.0020 % + 2.9E-04 psi
Fluke PG7601, N2
as gas medium | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 14 of 16
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Pressure,
(ADWT/ODWT)
(58 to 15 954) psi (gas)
(29 to 7977) psi (oil)
(145 to 39 885) psi (oil)
0.0048 % + .004 psi
0.0027 % + .0029 psi
0.0046 % + .015 psi
Fluke 7202
ADWT/ODWT
Vibration General
Purpose –
Acceleration
Sensitivity
Magnitude
(Up to 100 mV/gn
Up to 10 pC/gn)
(5 to 9) Hz
(10 to 99) Hz
100 Hz
(101 to 920) Hz
(921 to 5000) Hz
(5001 to 10 000) Hz
(10 to 15) kHz
2.3 %
1.7 %
1.3 %
1.4 %
1.7 %
2.2 %
2.8 %
Reference
accelerometer, back-to-
back comparison
method with Modal
Shop TMS 9155C
Vibration Cal System.
Data acquisition card
w/ 396C10/C11 air
bearing shaker
Force – Measuring
Equipment
Up to 1000 lbf
(>1000 to 5000) lbf
(>5000 to 10 000) lbf
(>10 000 to 25 000) lbf
(>25 000 to 50 000) lbf
(>50 000 to 100 000) lbf
3.1E-3 % full scale
4.6E-03 % full scale
0.036 % full scale
0.037 % full scale
0.023 % full scale
0.04 % full scale
Morehouse 1K dead
weight machine
Pratt & Whitney 5K
dead weight machine
Loadcell to loadcell
Comparison
Mass
1 mg to 5 g
(5 to 520) g
(453 to 22 679) g
(>22 679 to 45 358) g
(>45 358 to 63 501) g
0.036 mg + 7.9 ng/mg
0.11 mg + 0.93 µg/g
35 mg + 3.2 µg/g
54 mg + 2.3 µg/g
0.16 g
Mettler Toledo
XPE505C, mass pieces
Mettler Toledo
XPR64002LC, mass
pieces | ||
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 15 of 16
IV. Thermodynamic
Parameter/Range
Frequency
CMC2 (±)
Comments
Temperature –
Measure
0.01 °C
(-197 to 0) °C
(>0.01-230) °C
(>230-400) °C
(>400-660) °C
(660 to 1450) °C
0.009 °C
0.012 °C
0.019 °C
0.022 °C
0.026 °C
2.4 °C
Comparison with
SPRT/triple point
Comparison to SPRT
Comparison with type
S thermocouple
Relative Humidity
(10 to 90) % RH @
(-10 to 70) °C
0.7 % RH
Thunder Scientific
2500-LT
V. Time & Frequency
Parameter/Range
Frequency
CMC2 (±)
Comments
Frequency –
Measuring Equipment
10 MHz
1.5 part in 1013 Hz/ Hz
Fluke 910R
Frequency – Measure
1 mHz to 500 MHz
1 part in 1000 Hz/ Hz + 10µHz
HP 5345A
____________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The measurands stated are generated with the Fluke 5730, 5790B and 5520 series of instruments . This
capability is suitable for the calibration of the devices intended to measure the stated measurand in the
ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction
of the reading plus a fixed floor specification. | ||
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2322.01) 02/07/2025 Page 16 of 16
4 The measurands stated are measured with the HP 3458A. This capability is suitable for the calibration of
the devices intended to generate the measurand in the ranges indicated. CMCs are expressed as either a
specific value that covers the full range or as a combination of the fraction of the reading/output plus a
range specification.
5 In the statement of CMC the percentages are percentages of reading, unless otherwise noted.
6 In the statement of CMC t represents time in seconds. | ||
| 17 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- FLORIDA METROLOGYPort St. Lucie, FL · ~47 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Trescal, Inc. - Miami, FLBoca Raton, FL · ~64 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- M & M MetrologyDeerfield Beach, FL · ~68 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Technical Maintenance, Inc. - POMPANO BEACHPompano Beach, FL · ~77 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Kimball ElectronicHialeah, FL · ~125 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.