Registers refreshed 2026-11-20.See refresh dates
United States

Clark Dynamic Testing Laboratory, Inc.

1801 Route 51 S, 15025, Jefferson Hills, PA, United States

Visit website
A2LA 1337.02A2LA 1337.03ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
39
A2LA certificates
2
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 39 standard numbers and the 29 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series19
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
IEC 61000-4-10
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
Show all 19
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
IEC 61000-4-18
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC5
IEC 60006-2-30
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61131-1
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61373Railway applications - Rolling stock equipment - Shock and vibration tests
ASTM3
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM D4169
ASTM D4718
EN 50121 series3
EN 50121-3-1
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50121-5
IEC 60068 series3
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-3
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

EN 50270
FCC PART 15Radio Frequency Devices
ISO 2631-1Mechanical vibration and shock - Evaluation of human exposure to whole-body vibration - Part 1: General requirements
ISO 9227Corrosion tests in artificial atmospheres - Salt spray tests

Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.

Scope as published by A2LA

8 lines
A2LA

ISO/IEC 17025

Active

1337.02

The scope document we hold says it is valid until 2026-11-30.

View scope

Accredited scope, certificate 1337.02

LineMethodMatrixRange
1FCC CFR 47 Part 15B (Using ANSI C63.4:2014); FCC CFR 47 Part 18 (using MP-5:1986); ANSI C63.4; EN 55011; CISPR 11; CISPR 16-2-3; CISPR 16-2-1; CISPR 32; CISPR 12; MIL-STD-461 E-G, Methods RE101, RE102; MIL-STD-461 E-G, Methods CE101, CE102; IEC 61000-3-3; IEC 61000-3-2; IEC/EN 61000-4-2; IEC/EN 61000-4-3; IEC/EN 61000-4-4; IEC/EN 61000-4-5; IEC/EN 61000-4-6; IEC/EN 61000-4-8Automotive; Industrial; Off -Highway; Agricultural; Medical Devices; Defense/Military; Heavy Equipment; Transportation; Rail; Nuclear Power Generation; Aerospace; Electric Motors; Gearboxes; Drivetrain Componentsto 18 GHz
2IEC/EN 61000-4-9; IEC/EN 61000-4-10; IEC/EN 61000-4-11; IEC/EN 61000-4-29; IEC/EN 61000-4-12; IEC/EN 61000-4-13; IEC/EN 61000-4-18; MIL-STD-461E-G Methods RS101, RS103; MIL-STD-461E-G Methods CS101, MIL-STD-461E-F CS114; IEC/EN 61000-6-2; IEC/EN 61000-6-4; IEC/EN 61000-6-1; IEC/EN 61000-6-3; EN 50121-4; EN 50121-5; EN 50121-3-1; EN 50270; IEC/EN 60601-1-2; IEC/EN 61326-1; US NRC Regulatory Guide 1.180 Revision 2Industrial Environments; Residential Environments; Railway Applications; Gas Detection; Medical Equipment; Laboratory Equipment; Safety-Related Instrumentation and Control System-
347 Code of Federal Regulations; FCC KDB 974614, Appendix A, Table A.12; ANSI C63.4:2014; FCC MP-5:1986-to 18000 MHz
4ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

A2LA

ISO/IEC 17025

Active

1337.03

The scope document we hold says it is valid until 2026-11-30.

View scope

Accredited scope, certificate 1337.03

LineMethodMatrixRange
1MIL-STD-810C, D, E, F, G, H, Method 500; MIL-STD-202:105; RTCA/DO-160 (F and G) Section 4; IEEE 323, 344, 382, 693; AC 156, OSHPD, CBC 2013, IBC 2012; GR-63-CORE (NEBS); RTCA / DO 160 Section 4; RTCA / DO 160 Section 5, Category C only; RTCA / DO 160 Section 6; IEEE 323; MIL-STD-810B, C, D, E, F, G, H, Methods 501 and 502; MIL-STD-810B, C, D, E, F, G, H, Method 507; MIL-STD-202:103; MIL-STD-202:106; MIL-STD-202:107; MIL-STD-202:108; GR-63 CORE; IEC 60068-2-1; IEC 60068-2-3equipmentSee scope document
2IEC 600068-2-2; IEC 60006-2-30; IEC 61131-1; MIL-STD-833G/H; MIL-STD-833G/H; RTCA / DO 160 Section 7; MIL-STD-810B-H:516; MIL-STD-202:213; IEC 61373:2010; Arema C+S, Part 11.5.1; RTCA / DO 160E Section 8; RTCA / DO 160F Section 8; RTCA / DO 160G Section 8; MIL-STD-202:201; MIL-STD-202:204; MIL-STD-202:214; MIL-STD-810B 514; MIL-STD-810C 514; MIL-STD-810D 514; MIL-STD-810E 514; MIL-STD-810F 514; MIL-STD-810G 514; MIL-STD-810H 514; MIL-STD-167-1/1A; GR-63 CORE; IEC 61373:2010; IEC 600068-2-6; ASTM D4169; ASTM D4718; EN 61373; ISO 2631-1; AREMA C&S, Part 11.5.1; MIL-S-901D/E; MIL-DTL-90; RTCA / DO 160 Section 14; MIL-STD-810B-H:509; ISO 9227; IEC 60068-2-11; ASTM B117; MIL-STD-202:101; ANSI/FM 1950--
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1337.03) Revised 10/19/2026 Page 3 of 3 1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediately precedes the current version for a period of one year from the date of publication of the standard measurement method, per part C., Section 1 of A2LA R101 - General Requirements- Accreditation of ISO-IEC 17025 Laboratories.
4ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1801 Route 51 S, Jefferson Hills, PA, 15025, US

40.29118, -79.93199

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.