Registers refreshed 2026-11-08.See refresh dates
United States

Maxpro Corporation

427 Sargon Way, Unit D, 19044, Horsham, PA, United States

Visit website
A2LA 3912.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 3912.01 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3912.01) 01/22/2026 Page 2 of 3 Parameter/Equipment Range CMC2 (±) Comments Torque3 – Static, Manual Torque Wrenches (cont) (>250 to 600) lbf∙ft (>600 to 1000) lbf∙ft 3.8 lbf∙ft 7.7 lbf∙ft Torque transducers Torque3 – Dynamic Pneumatic Torque Wrench Pneumatic Torque Wrench Electronic Torque Wrench Battery Torque Wrench Electric Torque Wrench Hydraulic Torque Wrench Up to 200 lbf∙ft (>200 to 400) lbf∙ft (>400 to 1000) lbf∙ft (>1000 to 2400) lbf∙ft (>2400 to 6000) lbf∙ft (>6000 to 8000) lbfꞏft (>8000 to 11 000) lbfꞏft Up to 100 lbf∙ft (>100 to 400) lbf∙ft (>400 to 1000) lbf∙ft (>1000 to 2400) lbf∙ft (>2400 to 3600) lbf∙ft (>3600 to 4800) lbf∙ft (>4800 to 6000) lbf∙ft (>6000 to 11 500) lbf∙ft (25 to 1000) lbf∙ft (>1000 to 2400) lbf∙ft (>2400 to 3600) lbf∙ft (>3600 to 5000) lbf∙ft (>5000 to 6500) lbf∙ft (>6500 to 8000) lbf∙ft (>8000 to 11 000) lbf∙ft (50 to 1200) lbf∙ft (>1200 to 3000) lbf∙ft (50 to 500) lbf∙ft (>500 to 2000) lbf∙ft (>2000 to 4000) lbf∙ft (>4000 to 8000) lbf∙ ft (>8000 to 12 000) lbf∙ft (>12 000 to 20 000) lbf∙ft 11 lbf∙ft 18 lbf∙ft 21 lbf∙ft 45 lbf∙ft 60 lbf∙ft 92 lbf∙ft 110 lbf∙ft 1.6 lbf∙ft 3.6 lbf∙ft 8.1 lbf∙ft 18 lbf∙ft 27 lbf∙ft 33 lbf∙ft 39 lbf∙ft 120 lbf∙ft 6.9 lbf∙ft 16 lbf∙ft 22 lbf∙ft 29 lbf∙ft 89 lbf∙ft 120 lbf∙ft 160 lbf∙ft 14 lbf∙ft 30 lbf∙ft 9 lbf∙ft 20 lbf∙ft 94 lbf∙ft 160 lbf∙ft 200 lbf∙ft 300 lbf∙ ft Torque transducers Torque Transducers (5 to 200) ozfꞏin 0.16 ozfꞏin Moment arms & weights
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3912.01) 01/22/2026 Page 3 of 3 Parameter/Equipment Range CMC2, 6 (±) Comments Torque Transducers (cont) (>12 to 75) lbfꞏin (>75 to 150) lbfꞏin (>150 to 500) lbfꞏin (>500 to 1000) lbfꞏin (>83 to 260) lbf∙ft (>260 to 500) lbf∙ft (>500 to 1000) lbf∙ft (>1000 to 2000) lbf∙ft (>2000 to 8000) lbf∙ft (>8000 to 12 000) lbf∙ft (>12 000 to 20 000) lbf∙ft 0.047 lbf∙in 0.093 lbf∙in 0.16 lbf∙in 0.70 lbf∙in 0.071 lbf∙ft 0.31 lbf∙ft 0.64 lbf∙ft 0.81 lbf∙ft 1.7 lbf∙ft 5.9 lbf∙ft 10 lbf∙ft Moment arms & weights Torque Multipliers3 75 lbf∙ft (>75 to 1000) lbf∙ft (>1000 to 5600) lbf∙ft 6.4 % 2.4 % 1.6 % Torque transducer torque wrench ___________________________________________ 1 This laboratory offers commercial and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The type of instrument or material being calib rated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated.
4ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

427 Sargon Way, Unit D, Horsham, PA, 19044, US

40.18425, -75.13905

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.