Laboratorio Bonazzi
Strada Provinciale Nord, 52, 42017, Novellara, Italy
- Accredited standards
- 7
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 7 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 4832Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of coliforms - Colony-count technique
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 8553Milk - Enumeration of microorganisms - Plate-loop technique at 30 degrees C
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9622Milk and liquid milk products - Guidelines for the application of mid-infrared spectrometry
ISO 13366-2Milk - Enumeration of somatic cells - Part 2: Guidance on the operation of fluoro-opto-electronic counters
UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 6222:2001; UNI EN ISO 7899-2:2003; UNI EN ISO 9308-1:2017; ISO 4832:2006; MI 02 rev. 22/2025; MI 03 rev. 12/2025; MI 09 rev. 05/2023; MI 49 rev. 06/2022; MI 01 rev. 22/2025; ISO 9622:2013 (IDF 141:2013); ISO 13366-2:2006 (IDF 148-2:2006); ISO 8553:2004 (IDF 131:2004); DM 26/03/1992 SO n 67 GU n 90 16/04/1992 All 2 Met I; NMKL n 5 5th Ed 2001 - solo/only Met. B
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.
Scope as published by ACCREDIA
1 line
ISO/IEC 17025
Active00567
Accredited scope, certificate 00567
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI CEI EN ISO/IEC 17025:2018; UNI EN ISO 6222:2001; UNI EN ISO 7899-2:2003; UNI EN ISO 9308-1:2017; ISO 4832:2006; MI 02 rev. 22/2025; MI 03 rev. 12/2025; MI 09 rev. 05/2023; MI 49 rev. 06/2022; MI 01 rev. 22/2025; ISO 9622:2013 (IDF 141:2013); ISO 13366-2:2006 (IDF 148-2:2006); ISO 8553:2004 (IDF 131:2004); DM 26/03/1992 SO n 67 GU n 90 16/04/1992 All 2 Met I; NMKL n 5 5th Ed 2001 - solo/only Met. B | Drinking water | 1000 to 4861000 UFC/ml |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- LABORATORIO GAMMA DEI DOTT. PITTANO MASSIMO, PITTANO FABRIZIACavriago · ~23 kmACCREDIAShares 2 accredited methods and materialsEN ISO 6222:2001Drinking water
- S.E.A.R.CH.Noceto · ~44 kmACCREDIAShares 2 accredited methods and materialsEN ISO 6222:2001Drinking water
- La BeutaMalborghetto di Boara · ~73 kmACCREDIAShares 2 accredited methods and materialsEN ISO 6222:2001Drinking water
- Laboratorio di analisi acqueveneteMonselice · ~92 kmACCREDIAShares 2 accredited methods and materialsEN ISO 6222:2001Drinking water
- CRB - CENTRO RICERCHE BIOLOGICHE DI LANDUCCI GIUSEPPINAGuamo Capannori · ~116 kmACCREDIAShares 2 accredited methods and materialsEN ISO 6222:2001Drinking water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.