Delta TRAC, Division of Delta Sales Associates, Inc, 14221, Williamsville, NY, United States
Visit website- Accredited standards
- 10
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM B244
ASTM B499
ASTM B504
ASTM B567Standard Test Method for Measurement of Coating Thickness by the Beta Backscatter Method
ASTM B568
ASTM D523Standard Test Method for Specular Gloss
ASTM D2244
ASTM E1004
ASTM E2975
ASTM D523; ASTM B117
ASTM B568; ASTM B567; ASTM B504; ASTM B244; ASTM B499
ASTM B568; ASTM B499
ASTM E1004; ASTM E2975; ASTM D2244
Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-06.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active1569.01
The scope document we hold says it is valid until 2028-04-30.
Accredited scope, certificate 1569.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM B568; ASTM B567; ASTM B504; ASTM B244; ASTM B499 | - | 0.2 to 40 mils |
| 2 | ASTM B568; ASTM B499 | Alloy Coated Standards; Foil Standards | - |
| 3 | ASTM E1004; ASTM E2975; ASTM D2244 | Non-Ferrous Metals; Electrical Conductivity Standards; Standard fluids | - |
| 4 | ASTM D523; ASTM B117 | - | - |
| 5 | - | Oven data logger with K type thermocouples; Process calibrator with K type thermocoupleShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1569.01) 04/29/2026 Page 5 of 5
Parameter/Equipment
Range
CMC2 (±)
Comments
Temperature –
Measure3
(Oven Profile)
(-200 to 1300) °C
0.41 °C
Oven data logger
with K type
thermocouples
Temperature –
Measure3
(Thermocouple)
(-100 to 400) °C
0.86 °C
Process calibrator
with K type
thermocouple
_______________________________________
1 This laboratory offers commercial and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of
measurement that a laboratory can achieve within its scope of accreditation when performing more or
less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment.
CMCs Capabilities represent expanded uncertainties expressed at approximately the 95 % level of
confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific
calibration performed by the laboratory may be greater than the CMC due to the behavior of the
customer’s device and to influences from the circumstances of the specific calibration.
3 Field calibration service is available for this calibration . Please note the actual measurement
uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found
on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of
calibration and for other possible adverse effects such as those caused by transportation of the
calibration equipment. The usual allowance for the actual uncertainty introduced by the item being
calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual
measurement uncertainty achievable on a customer’s site being larger than the CMC.
4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | - |
| 6 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Delta TRAC, Division of Delta Sales Associates, Inc, Williamsville, NY, 14221, US
42.96378, -78.73773
Open in MapsOther Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- Ghesquiere Plastic TestingHarper Woods, MI · ~347 kmA2LAShares 1 accredited test methodASTM D523
- Michigan Testing InstituteSterling Heights, MI · ~353 kmA2LAShares 1 accredited test methodASTM D523
- Intertek Testing Services NAPlymouth Township, MI · ~394 kmA2LAShares 1 accredited test methodASTM D523
- Technical Finishing, Inc. - TestFlint, MI · ~403 kmA2LAShares 1 accredited test methodASTM D523
- National Exposure TestingSylvania, OH · ~432 kmA2LAShares 1 accredited test methodASTM D523
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.